User manual | Siemens Hicom 300 E CS Rel 6.5 PBX with CallManager using
Add to my manuals34 Pages
Siemens Hicom 300 E CS is a feature-rich PBX system designed to meet the communication needs of small to medium-sized businesses. With its advanced call handling capabilities, the Hicom 300 E CS enables efficient call routing, call forwarding, and conferencing. It also offers a range of customizable features, allowing businesses to tailor the system to their specific requirements. The Hicom 300 E CS supports a variety of communication devices, including traditional analog phones, digital system phones, and IP phones.
advertisement
Application Note
Siemens Hicom 300 E CS Rel 6.5 PBX with CallManager using
2621-T1 PRI NI-2 Gateway
This application note illustrates for connectivity of the Siemens Hicom 330 E Rel 3.1
PBX with Cisco CallManager using Cisco 2621-T1 PRI NI1 Gateway.
Integration Description
Connectivity is achieved by using the industry standard PRI NI-2 protocol. The
Siemens Hicom 300 E CS can be configured as either NETWORK or USER side.
Cisco Systems Hardware and
Software Requirements
• Hardware (Cisco 2621Gateway):
2MFT T1 Port
• Software: CallManager Release 3.1
PBX Hardware and Software
Requirements
• Hardware: TMDN or TMDN 64
• Software: Version 6.5
Features Supported
• When calling from Cisco 7960 IP phone to Siemens digital phone, Calling/Called
Number is displayed on both phones after the call is answered.
• When calling from Siemens digital phone to Cisco 7960 IP phone, IP phone displays Connected Number after the call is answered. Siemens phone however does NOT get updated when the call is answered. It displays the dialed numbers instead. (i.e. Access
Code + extension number). It was verified using ISDN protocol analyzer that the CallManager was not sending
"Connected Number” information in the connect message back to PBX.
• When a call is answered, the display on the Siemens phone is only active
(Calling Number displayed) for approximately 4 seconds. Thereafter, the screen goes blank. This could be caused by a timer feature that is expiring for the display.
Key Features Supported
Calling/Called Number
Key Features Not Supported
Calling/Called Name
Limitations
User/Network Settings
The Cisco 2621 router with ISDN switch type setting of primary-ni supports both protocol sides by using the “isdn protocol-emulate network/user” command.
When the router is set to emulate Network side and the Siemens is set to emulate User
Calling Name and Number feature
• Calling Name delivery and presentation features are not supported by the
Siemens Hicom 330 E CS PBX.
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 1 of 34
side, the Siemens PBX must send at least 10 digits for the router to properly route the call. Otherwise, the Cisco 2621 router sends back a release message containing a release cause of “Invalid Number Format”.
Network Topology
Figure 1 Basic Setup
Configuration
Configuringthe Siemens Hicom 300 E CS PBX
Use the following steps to configure the Siemens Hicom 300 E CS PBX:
Step 1.
Add the new access code to DPLN.
Step 2.
Add the new trunk board using BCSU.
Step 3.
Configure COT.
Step 4.
Configure COP.
Step 5.
Add the new trunk group access code using TGACC.
Step 6.
Add the channels using TCSU.
Step 7.
Configure LROUT.
Step 8.
Configure LODR.
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 2 of 34
Siemens Hicom 330 E CS PBX Configuration Menus and Commands
Step 1.
Add the new access code to DPLN.
<dis-dpln
TYPE = dgts
DGTS = ;
DIS-DPLN:DGTS,;
H500: AMO DPLN STARTED
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| 0 |....* ..... ..... .......| GENANS | | |
| 1 |.*.** *.*** **... ......*| CO | | |
| 2000 - 2002 |.**** ***** ***.* ......*| STN | | |
| 2003 - 2024 |.**** ***** ***.* ......*| STN | R | |
| 2025 - 2026 |.**** ***** ***.* ......*| STN | | |
| 2027 - 2099 |.**** ***** ***.* ......*| STN | R | |
| 37 - 41 |.*.** *.*** **... ......*| CO | | |
| 43 - 48 |.**** ***** **... ......*| TIE | | |
| 49 - 50 |.*.** *.*** **... ......*| CO | | |
| 70000 - 70999 |.**** ***** ***.* ......*| STN | R | |
| 71000 |.**** ***** ***.* ......*| STN | | 1 |
| 71001 - 79998 |.**** ***** ***.* ......*| STN | R | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| 79999 |.**** ***** ***.* ......*| STN | | |
| 9 |.*.** *.*** **... ......*| CO | | |
| *0 |*...* ..**. ..... ......*| ACDWORK | | |
| *2 |*...* ..**. ..... ......*| ACCTCODE | | |
| *3 |....* ..**. ..... ......*| PUDIR | | |
| *4 |*...* ..**. ..... ......*| CONFRNC | | |
| *52 |....* ..... ..... .......| MWCAN | | |
| *530 |....* ..... ..... ......*| PMCANCEL | | |
| *532 |....* ..... ..... ......*| PMCALLBK | | |
| *563 |*.... ..**. ..... .......| BADLINE | | |
| *564 |*...* ..**. ..... ......*| ACDLOGON | | |
| *565 |*...* ..**. ..... ......*| ACDLOGOF | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 3 of 34
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *570 |*...* ..**. ..... .......| ACDPQ | | |
| *571 |*...* ..**. ..... .......| ACDPS | | |
| *572 |....* ..... ..... .......| RING | | |
| *580 |*...* ..**. ..... .......| ACDSQ | | |
| *581 |*...* ..**. ..... .......| ACDSS | | |
| *6 |***** ..**. ..... .......| ROLMPARK | | |
| *7 |*...* ..**. ..... .......| CONSULT | | |
| *80 - *89 |.**** ..**. ..... .......| PARK | | |
| *9 |....* ..**. ..... .......| HOLD | | |
| **0 |.***. ..... ..... .......| BVSL | | |
| **1 |*.... ..**. ..... ......*| TOGGLE | | |
| **3 |....* ..**. ..... ......*| PU | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| **41 - **48 |..... ..*.. ..... ......*| CONFRMV | | |
| **50 |*...* ..**. ..... .......| CAFGRAVL | | |
| **51 |*...* ..**. ..... .......| CAFGRUNA | | |
| **6 |....* ..**. ..... .......| INTERCOM | | |
| **8 |....* ..... ..... .......| MWANS | | |
| ***4 |..... ..... ..... ......*| CONFRMVL | | |
| ***5 |....* ..... ..... .......| MONSLNT | | |
| **#65 |*...* ..**. ..... .......| CAFGROFF | | |
| *#01 |....* ..... ..... .......| RCHNL | | |
| *#02 |....* ..... ..... .......| RTERM | | |
| *#03 |....* ..... ..... .......| LTERM | | |
| *#04 |..... *.... *.... .......| PRITEST | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *#274 |*...* ..... ..... .......| WS | | |
| *#50 |*...* ..**. ..... .......| CAFAVLB | | |
| *#51 |*...* ..**. ..... .......| CAFUNAV | | |
| *#55 |*...* ..**. ..... .......| CAFFWD | | |
| *#56 |*...* ..**. ..... .......| CAFFWDC | | |
| *#57 |....* ..... ..... .......| PIDON | | |
| *#58 |....* ..... ..... .......| PIDOFF | | |
| *#590 |....* ..... ..... .......| DCOSX | | |
| *#591 |....* ..... ..... .......| ACOSX | | |
| *#63 |***** ***** ***** *******| CLEAR | | |
| *#65 |*...* ..**. ..... .......| CAFLOGOF | | |
| *#735 |....* ..... ..... .......| RELOCATE | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 4 of 34
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| *#738 |....* ..... ..... .......| SET | | |
| *#97 |..*.. *.... ..... .......| COXFER | | |
| #0 |*...* ..**. ..... ......*| ACDUNAV | | |
| #1 |*.... ..*.. ....* .......| ACBK | | |
| #2 |*...* ..**. ..... .......| PRION | | |
| #3 |.**.* ..**. ..... ......*| SPDI | | |
| #4 |***.* ..**. ....* ......*| SNR | | |
| #5 |....* ..... ..... .......| ADND | | |
| #61 |.**** ..*** **... ......*| SPDC1 | | |
| #62 |.**** ..*** **... ......*| SPDC2 | | |
| #80 |*...* ..**. ..... .......| BROADCST | | |
| #81 |*...* ..**. ..... .......| SPKRCALL | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #8378 |..... ..... ....* .......| HWTEST | | |
| #91 |....* ..... ....* .......| CFWVABTH | | |
| #92 |....* ..... ....* .......| CFWVAEXT | | |
| #93 |....* ..... ....* .......| CFWVAINT | | |
| #94 |....* ..... ....* .......| CFWVB | | |
| #95 |....* ..... ....* .......| CFWVBNA | | |
| #96 |....* ..... ....* .......| CFWVNA | | |
| #*056 |....* ..... *.... .......| DATA56 | | |
| #*1 |***** ..**. ..... .......| MWACT | | |
| #*2 |*...* ..**. ..... .......| BUZZ | | |
| #*329 |.**.* *.*** **... .......| FAX | R | |
| #*4 |*...* ..**. ..... .......| VCECALL | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #*75 |....* ..... ..... .......| DIGIDAT | | |
| #*76 |....* *.**. ..*.* .......| SWITCH | | |
| #*77 |....* *.*** ***.* .......| DTE | | |
| #*78 |....* ..**. ....* .......| CODE | | |
| #*79 |....* ..**. ....* .......| SPEED | | |
| #*8 |***** ****. ..*** *****..| MWCANORI | | |
| #*90 |....* ..... ....* .......| HUNTPROG | | |
| #*92 |....* ..... ..... .......| AHTVCE | | |
| #*93 |....* ..... ..... .......| DHTVCE | | |
| #*94 |....* ..... ..... .......| AHTDTE | | |
| #*95 |....* ..... ..... .......| DHTDTE | | |
| #*96 |....* ..... ..... .......| AHTFAX | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 5 of 34
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| #*97 |....* ..... ..... .......| DHTFAX | | |
| #*99 |....* ..... ....* .......| HUNTCLR | | |
| ##0 |*...* ..**. ..... ......*| ACDAVLB | | |
| ##1 |....* ..... ..... .......| DCBK | | |
| ##2 |*...* ..**. ..... .......| PRIOFF | | |
| ##3 |....* ..... ....* .......| SPDIPROG | | |
| ##4 |*...* ..**. ..... ......*| LNR | | |
| ##5 |....* ..... ..... .......| DDND | | |
| ##7 |*.... ..... ..... .....*.| KNOVR | | |
| ##8 |***** ..**. ..... .......| DTA | | |
| ##91 |....* ..... ....* .......| CFWVAOFF | | |
| ##*78 |....* ..**. ....* .......| RESET | | |
--------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 |
--------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT ANALYSIS| | |
| DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE|
| |12345 67890 12345 6789012| (SKIP DIGIT) | | |
--------------------------------------------------------------------------
| ###1 |*.... ...*. ..... .......| TRACE | | |
| ###20 |..... **..* **... .......| MILLWAT | | |
| ###21 |..... **..* **... .......| LOOPBACK | | |
| ###22 |..... **..* **... .......| SILENCE | | |
| ###23 |..... **..* **... .......| COMBO | | |
| ###4 |*.... ..... ..... .......| THRCONF | | |
| ###6 |....* ..... ..... .......| MONTONE | | |
--------------------------------------------------------------------------
AMO-DPLN -135 DIALING PLANS, FEATURE ACCESS CODES
DISPLAY COMPLETED;
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 6 of 34
Step 2.
Add the new trunk board using BCSU.
<dis-bcsu
TYPE = tmd;
DIS-BCSU:TMD;
H500: AMO BCSU STARTED
---------------------------------------------------------------
| DETAILS OF TMD BOARD AT ADDRESS (LTG.LTU.SLOT) = 1. 2.103 |
| |
| CABTYP = 1 TIMTYP = SYST SIGTYP = MOS |
| FRAME = ESF TABS = NO FCTID = 2 |
| BI8SUB = YES BIVDET = NO |
|-------------------------------------------------------------|
| RDRATIO = 6 RDTH = 2500 RDQUAL = 15000 |
| YLSEND = 5000 YLTH = 400 YLQUAL = 100 |
| LOS = 150 AOS = 4000 |
| SESDISTH = 10 SESREQTH = 10 |
| OESDISTH = 30 OESDISIN = 24-00-00 |
| OESREQTH = 4 OESREQIN = 04-00-00 |
|-------------------------------------------------------------|
| NETUSR = NETWK ACKTIM = 1000 DLVTIM = 30000 |
| OCTMAX = 260 RETMAX = 3 WINDOW = 1 |
| CRIDC = TTSC = NSFIV = |
| NSFTSC = PFDGT = |
|-------------------------------------------------------------|
| IGN = 0 IID = 1 |
---------------------------------------------------------------
AMO-BCSU -135 BOARD CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
Step 3.
Configure COT.
<dis-cot
COTNO = 0;
DIS-COT:0;
H500: AMO COT STARTED
|D|A|D|D|D|M|S|V|E|E|A|R|
|I|N|S|S|I|D|A|L|S|S|N|F|
|T|S|A|A|S|R|T|S|P|P|I|L|
| |R| |S| | | |A|A|D|D|A|
| | | | | | | |T|N|N|N|S|
| | | | | | | | |I|I|I|H|
COT | | | | | | | | | |S|S| |
----+-+-+-+-+-+-+-+-+-+-+-+-+
0 | | | | | | | | | | | | |
----+-+-+-+-+-+-+-+-+-+-+-+-+
AMO-COT -135 CLASS OF TRUNK FOR CALL PROCESSING
DISPLAY COMPLETED;
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 7 of 34
Step 4.
Configure Class of Parameter for device handler using COP.
<dis-cop
COPNO = 0;
DIS-COP:0;
H500: AMO COP STARTED
| | | | | |
| | S E A | | | |
| | T E S N | | | |
| | A S V S P I D |DD| S| |
| | D Z L P D D T |TT| U| P |
| | I A A S S A N N O |MM| P| D |
|COP| A N C A A N I I N |FF| V| P |
|IDX| L S K T T I S S E | L|12|1234|
+---+-------------------+--+--+----+
| 0| | | | |
+---+-------------------+--+--+----+
AMO-COP -135 CLASS OF PARAMETER
DISPLAY COMPLETED;
Step 5.
Add the new trunk group access code using TGACC.
<dis-tgacc
TGRP = 40;
DIS-TGACC:40;
H500: AMO TGACC STARTED
+------------------------------------------------------------------------------+
| TGRP NUMBER : 40 TGRP NAME : T1PRI /N MAXIMUM NO: 23 |
| SUBGROUP NUMBER: 11 DEVICE TYPE: PRI B DIR TYPE : BOTH |
| ACD THRESHOLD : * TRACENO : 0 USAGE TYPE: TERR |
| ALLOCATED TO AT LEAST ONE ROUTE GDTR RULE : 0 |
| SELECTION : LOW CFBLOCK : DISABLED |
| THE FOLLOWING PORTS (LTG-LTU-SLOT-CIRCUIT) ARE ALLOCATED: |
+------------------------------------------------------------------------------+
| 1- 2-103- 1| 1- 2-103- 2| 1- 2-103- 3| 1- 2-103- 4| 1- 2-103- 5| 1- 2-103- 6|
+------------------------------------------------------------------------------+
| 1- 2-103- 7| 1- 2-103- 8| 1- 2-103- 9| 1- 2-103-10| 1- 2-103-11| 1- 2-103-12|
+------------------------------------------------------------------------------+
| 1- 2-103-13| 1- 2-103-14| 1- 2-103-15| 1- 2-103-16| 1- 2-103-17| 1- 2-103-18|
+------------------------------------------------------------------------------+
| 1- 2-103-19| 1- 2-103-20| 1- 2-103-21| 1- 2-103-22| 1- 2-103-23| - - - |
+------------------------------------------------------------------------------+
AMO-TGACC-135 TRUNK GROUP ACCESS CODE
DISPLAY COMPLETED;
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 8 of 34
Step 6.
Add the channels using TCSU.
TCSU – B Channel
<dis-tcsu
PEN1 = 1-2-103-1;
DIS-TCSU:1-2-103-1;
H500: AMO TCSU STARTED
+------------------------------------------------------------------------+
| PEN: 1- 2-103- 1 INS: Y BOARD: TMDN64P DEV: PRIB TGRP: 40 |
+------------------------------------------------------------------------+
| TRKID : 0040 TCCID : |
| CCT : /0040 |
| |
| ACDATA : 0 DITIDX : 0 LOCANA : |
| ATNTYP : ISDN DPLN : 0 REMANA : |
| COPNO : 0 ITR : 0 SIDANI : N |
| COSNO : 75 LCRCOSD : 5 SRTIDX : 3 |
| COTNO : 0 LCRCOSV : 5 TRTBL : DIDCR |
| DEDSVC : NONE FACILITY : * |
+------------------------------------------------------------------------+
AMO-TCSU -135 TRUNK CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
TCSU – D Channel
<dis-tcsu
PEN1 = 1-2-103-24;
DIS-TCSU:1-2-103-24;
H500: AMO TCSU STARTED
+------------------------------------------------------------------------+
| PEN: 1- 2-103-24 INS: Y BOARD: TMDN64P DEV: PRID |
+------------------------------------------------------------------------+
| TCCID : |
| CCT : |
| |
| ACDATA : 0 DEDSCC : INTERFID : |
| COPNO : 0 DITIDX : ITR : 0 |
| COTNO : 0 DPLN : 0 PROTOCOL : NI2 |
| |
| TMR301 : 300 SEC. TMR308 : 4 SEC. TMR313 : 4 SEC. |
| TMR303 : 4 SEC. TMR309 : 90 SEC. TMR316 : 30 SEC. |
| TMR305 : 30 SEC. TMR310 : 30 SEC. TMR322 : 4 SEC. |
| TDELAY : 3000 MSEC. BEARER: ONE |
| NCT : N TNCT : |
+------------------------------------------------------------------------+
AMO-TCSU -135 TRUNK CONFIGURATION, SWITCHING UNIT
DISPLAY COMPLETED;
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 9 of 34
Step 7.
Configure LROUT.
<dis-lrout
ROUTE = 40;
DIS-LROUT:40;
H500: AMO LROUT STARTED
LCR ROUTE DEFINITION TABLE
--------------------------
-------------------------------------------------------------------------
|ROUTENUM = 40 SCHED A = X AORT = INFORMATION |
|ROUTEELE = 1 B = AUTH = 1 TRANS CAP = S3V |
|BEARER = ONE C = ONHKQ = Y TRKSIG = PRI |
|BANDWTH = 1 D = OFFHKQ = Y SCCID = |
|TRUNKGRP = 40 E = ODRNUM = 1 SVCVCE = NON |
|MASTGRP = 8 F = APLTYP = VD SVCN-V = NON |
|ROUTSERV = N G = FACNUM = |
| H = |
-------------------------------------------------------------------------
END OF LCR ROUTE DEFINITION TABLE DISPLAY
AMO-LROUT-135 ROUTE DEFINITION DETERMINATION PACKAGE
DISPLAY COMPLETED;
Step 8.
Configure LODR.
<dis-lodr
RANGE =
DIS-LODR:;
H500: AMO LODR STARTED
<< DISPLAY LCR OUTDIAL RULE >>
ODR NO COMMAND BRANCH VALUE
------ ------- ------------
1 ECHOALL
END
--------AMO-LODR -135
DISPLAY COMPLETED;
AMO LCR ODR FOR SWITCHING UNIT
<
-------- END OF DISPLAY
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 10 of 34
Configuring the Cisco CallManager
Figure 1
Configuring the 6608-E1 Gateway
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 11 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 12 of 34
Route Pattern Configuration
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 13 of 34
Test Results
As shown in the diagram below, a Siemens Hicom 300 E CS PBX was connected via an ISDN T1 PRI link to a Cisco
2621, which in turn, was connected to an Ethernet switch. The interoperability testing involved Layers 1, 2 and 3 on the ISDN PRI link between a Cisco 2621 and the PBX.
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 14 of 34
Test Configuration
Layer 1 (Physical Layer)
The Siemens configuration screen for the DS1 trunk interface is reached with the command:
<cha-bssu
Layers 2 & 3 (Q.921 and Q.931)
Layer 2 and 3 packet exchanges were monitored using an Acacia Clarinet protocol analyzer, bridged across the PRI link in high impedance mode.
Layer 2 Q.921 packets were monitored to ensure that each PBX/2621 software configuration properly exchanged
SABME/UA packets to initialize the ISDN link, and then RR packets were exchanged every 30 seconds.
Layer 3 Q.931 packets were monitored to ensure that the appropriate call setup/teardown packets were exchanged for each configuration, and that the SETUP packets contained the mandatory Information Elements (IEs) with the necessary details, as well as optional IEs such as Calling Name and Number.
Telephone calls were made end-to-end in both directions through the Cisco 2621Gateway, and a check was made to ensure that there was an audio path in both directions for each call.
User/Network Settings
The Cisco 2621Gateway with ISDN protocol type setting of primary-ni supports both protocol sides by selecting
“Network/User” in the protocol side field when configuring the Gateway via CallManager.
The “Network/user” choice for the Siemens Hicom 300 E PBX is made by deactivating the B channels/D-channel
(<dea-dssu) and the DS1 board (<dea-bssu) consecutively. A change command is then issued to the Board
Configuration Switching Unit (BCSU) to get to the “network/user” prompt (<cha-bcsu). The DS1 board by
(<act-bssu), the D-channel, and B-channels are then reactivated (<act-dssu), after the settings are changed.
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 15 of 34
.
Table 1 PBX 1 - NI2 (Network) Cisco 2621 Gateway - primary-ni(User)
Siemens Hicom 330 E CS
Switch-type/ Protocol side setting
NI2 / Network
Cisco Cisco 2621_B ISDN protocol-type/Protocol side setting isdn switch-type primary-ni isdn protocol-emulate user
Table 2 Basic Calls: (Enbloc Sending)
Calls Made
Phone C to Phone A
Call
Comp?
Phone A to Phone C Yes
Yes
“Calling
Number”
Passed to
Final
Destination?
“Calling
Name”
Passed to
Final
Destination?
Yes No
“Called
Number”
Passed to
Orig. Side?
No
1
Yes No Yes
“Called
Name”
Passed to
Orig. Side?
No
No
Notes
2
3
1. CallManager is not sending "Connected Number" information in the connect message back to PBX.
2. The Siemens PRI interface with ETSI setting does not support “Calling Name” presentation Feature.
3. The display on the Siemens phone is oly active (Calling Number is displayed) for apporximately 4 seconds, thereafter the displays goes blank. This could be caused by a display timer feature that expires.
Table 3 Call Transfers: (Supervised Local Transfers)
Calls Made
Phone C to Phone
A Xfr to Phone B
Phone A to Phone
C Xfr to Phone D
Call
Comp?
Yes
Yes
Orig.
“Calling
Number” displayed on
Final Dest.
phone?
Yes
Orig.
“Calling
Name” displayed on
Final Dest.
phone?
No
“Called
Number” display on
Orig. phone updated after transfer?
No
Yes No No
“Called
Name” display on
Orig. phone updated after transfer?
No
Notes
No
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 16 of 34
Table 4 Call Conferencing (Local)
Calls Made
Call
Comp?
Phone C to Phone A,
Phone A conf Phone B
Yes
Phone C to Phone A,
Phone C conf Phone D
Yes
Phone A to Phone C,
Phone C conf Phone D
Yes
Phone A to Phone C,
Phone A conf Phone B
Yes
“Calling
Number”
Passed to remaining conferee when the conferencing phone drops out?
(A Drops out)
Yes
(C Drops out)
No
(C Drops out)
No
(A Drops out)
No
“Calling
Name” displayed on remaining conferee when the conferencing phone drops out?
(A Drops out)
No
(C Drops out)
No
(C Drops out)
No
(A Drops out)
No
“Connected
Number” updated on
Orig. Caller phone display when a conferee drops out?
(A Drops out)
No
(D Drops out)
No
(C Drops out)
No
(B Drops out)
No
“Connected
Name” updated on
Orig. Caller phone display when a conferee drops out?
(A Drops out)
No
(D Drops out)
No
(C Drops out)
No
(B Drops out)
No
Notes
Table 5 Call Forward (Local)
Calls Made
Phone C to Phone
A fwd to Phone B
Phone A to Phone
C fwd to Phone D
Yes
Call
Comp?
Yes
Original
“Calling
Number”
Passed to Final
Dest.?
Original
“Calling
Name”
Passed to Final
Dest.?
Yes No
Yes No No
Forwardi ng
“Called
Number”
Pased to
Final
Dest.?
Forwardi ng
“Called
Name”
Displaye d on
Final
Dest.?
No No
Final dest.
“Connec ted
Number” updated at orig.
side?
No
Final dest.
“Connec tedName
” updated at orig.
side?
No
Notes
No No No
Test Setup 2
Setup was as follows:
• PBX1 configured as NI2, emulates User
• Cisco Cisco 2621Gateway configured as PRI NI2, emulates Network
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 17 of 34
.
Table 6 Switch and Gateway Settings
Siemens Hicom 330 E CS
Switch-type/ Protocol side setting
NI2/User
Cisco 2621_B ISDN protocol-type/
Protocol side setting isdn switch-type—primary-ni isdn protocol—emulate network
When the Cisco 2621 router is set to emulate Network side, the Siemens PBX must send at least 10 digits for the router to properly route the call. Since the PBX is configured for 4 digit dialing, calls were tested in one direction only, from Cisco 7960 IP phone to Siemens digital phone. The test results are expected to be the same. Refer to the tables 2 - 7 for details.
Appendix A
Call Manager Software Release:
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 18 of 34
Siemens Hicom 330 E CS Software release
-------------------------------------------------------------------------------
TERMINAL 1 L O G O N 01-09-18 11:40:46
-------------------------------------------------------------------------------
<dis-ansu
DIS-ANSU;
H500: AMO ANSU STARTED
APS TYPE | NAME | SP REFERENCE NO.
-------------+----------+------------------
SWU RES-CODE | S0-ET0SC | P30252B6500S00101
SWU AMO-CODE | B0-ET0BC | P30252B6500B00101
SWU RES-TEXT | S0-TTDSD | P30252B650DS00101
SYSTEM NUMBER | DB SUBSYSTEM NAME
------------------+------------------
00000000000095393 | DB_SUSY_ZDBCCDSF
00000000000095393 | DB_SUSY_ZDBCCDS0
00000000000095393 | DB_SUSY_ZDBCCDS1
00000000000095393 | DB_SUSY_ZDBCCDS2
00000000000095393 | DB_SUSY_ZDBCCDSB
00000000000095393 | DB_SUSY_ZDBCCDSC
AMO-ANSU -135 ENTERING THE SYSTEM NUMBERS INTO THE SWU DATABASE
DISPLAY COMPLETED;
<
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 19 of 34
Cisco 2621 Router Configuration
2621_B#sh ver
Cisco Internetwork Operating System Software
IOS (tm) C2600 Software (C2600-JS-M), Version 12.2(3.5)T, MAINTENANCE INTERIM S
OFTWARE
TAC Support: http://www.cisco.com/tac
Copyright (c) 1986-2001 by cisco Systems, Inc.
Compiled Fri 03-Aug-01 22:45 by ccai
Image text-base: 0x80008088, data-base: 0x81631DD8
ROM: System Bootstrap, Version 12.1(3r)T2, RELEASE SOFTWARE (fc1)
2621_B uptime is 1 week, 4 days, 3 hours, 15 minutes
System returned to ROM by power-on
System image file is "flash:c2600-js-mz.122-3.5.T" cisco 2621 (MPC860) processor (revision 0x200) with 56320K/9216K bytes of memory
.
Processor board ID JAD051516TX (503811939)
M860 processor: part number 0, mask 49
Bridging software.
X.25 software, Version 3.0.0.
SuperLAT software (copyright 1990 by Meridian Technology Corp).
TN3270 Emulation software.
Primary Rate ISDN software, Version 1.1.
2 FastEthernet/IEEE 802.3 interface(s)
24 Serial network interface(s)
2 Channelized T1/PRI port(s)
32K bytes of non-volatile configuration memory.
16384K bytes of processor board System flash (Read/Write)
Configuration register is 0x2102
2621_B#
_______________________________________________________________________________________
__
2621_B#sh diag
Slot 0:
C2621 2FE Mainboard Port adapter, 2 ports
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 2.0
PCB Serial Number : JAD051516TX (503811939)
Part Number : 73-3200-08
RMA History : 00
RMA Number : 0-0-0-0
Board Revision : A0
Deviation Number : 0-21249
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 A2 41 02 00 C1 17 4A 41 44 30 35 31
0x10: 35 31 36 54 58 20 28 35 30 33 38 31 31 39 33 39
0x20: 29 82 49 0C 80 08 04 00 81 00 00 00 00 42 41 30
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 20 of 34
0x30: 80 00 00 53 01 FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
Slot 1:
High Density Voice Port adapter
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware Revision : 1.1
Top Assy. Part Number : 800-03567-01
Board Revision : F1
Deviation Number : 0-0
Fab Version : 02
PCB Serial Number : JAB05080LU9
RMA Test History : 00
RMA Number : 0-0-0-0
RMA History : 00
EEPROM format version 4
EEPROM contents (hex):
0x00: 04 FF 40 00 CC 41 01 01 C0 46 03 20 00 0D EF 01
0x10: 42 46 31 80 00 00 00 00 02 02 C1 8B 4A 41 42 30
0x20: 35 30 38 30 4C 55 39 03 00 81 00 00 00 00 04 00
0x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
VIC Slot 0:
T1 (2 Port) Multi-Flex Trunk (Drop&Insert) WAN Daughter Card
Hardware revision 1.0 Board revision B0
Serial number 17759676 Part number 800-04614-01
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 24 01 00 01 0E FD BC 50 12 06 01 00 00 00 00
0x30: 58 00 00 00 00 01 15 00 FF FF FF FF FF FF FF FF
HDV firmware: Compiled Fri 23-Mar-01 00:20 by miriyala
HDV memory size 524280 heap free 175065
2621_B#
_______________________________________________________________________________________
__
2621_B#sh controllers t1 1/0
T1 1/0 is up.
Applique type is Channelized T1
Cablelength is long gain36 0db
No alarms detected.
alarm-trigger is not set
Version info Firmware: 20010710, FPGA: 15
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 21 of 34
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (184 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
2621_B#
_______________________________________________________________________________________
__
2621_B#sh conf
2621_B#sh configuration
Using 1824 out of 29688 bytes
!
version 12.2
no parser cache service timestamps debug datetime msec localtime show-timezone service timestamps log uptime no service password-encryption
!
hostname 2621_B
!
no logging buffered enable password cisco
!
!
!
memory-size iomem 15 voice-card 1
dspfarm
!
ip subnet-zero
!
!
no ip domain-lookup
!
isdn switch-type primary-ni
!
!
!
!
!
!
voice class codec 1
codec preference 1 g729r8
codec preference 2 g711ulaw
codec preference 3 g711alaw
!
!
!
controller T1 1/0
framing esf
linecode b8zs
pri-group timeslots 1-24
!
controller T1 1/1
shutdown
framing esf
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 22 of 34
linecode b8zs
!
!
!
!
interface FastEthernet0/0
ip address 192.168.100.2 255.255.255.0
no ip mroute-cache
load-interval 30
no keepalive
speed auto
half-duplex
!
interface FastEthernet0/1
ip address 10.1.1.129 255.255.255.0
no ip mroute-cache
duplex auto
speed auto
!
interface Serial1/0:23
no ip address
no logging event link-status
isdn switch-type primary-ni
isdn incoming-voice voice
isdn T309-enable
isdn T306 30000
isdn T310 40000
no cdp enable
!
router rip
network 1.0.0.0
network 192.168.100.0
!
ip classless no ip http server ip pim bidir-enable
!
dialer-list 1 protocol ip permit dialer-list 1 protocol ipx permit
!
!
snmp-server packetsize 4096 snmp-server manager tftp-server nvram call rsvp-sync
!
voice-port 1/0:23
!
!
mgcp profile default
!
dial-peer cor custom
!
!
!
dial-peer voice 1 pots
destination-pattern 2...
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 23 of 34
direct-inward-dial
port 1/0:23
prefix 2
!
dial-peer voice 3 voip
destination-pattern 5...
progress_ind setup enable 1
voice-class codec 1
session target ipv4:10.1.1.2
dtmf-relay h245-alphanumeric
!
!
line con 0
exec-timeout 0 0 line aux 0
exec-timeout 0 0 line vty 0 4
exec-timeout 0 0
password cisco
login line vty 5 15
exec-timeout 0 0
login
!
scheduler allocate 3996 1000
!
end
2621_B#
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 24 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 25 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 26 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 27 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 28 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 29 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 30 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 31 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 32 of 34
Cisco Systems, Inc.
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Page 33 of 34
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
European Headquarters
Cisco Systems International BV
Haarlerbergpark
Haarlerbergweg 13-19
1101 CH Amsterdam
The Netherlands www-europe.cisco.com
Tel: 31 0 20 357 1000
Fax: 31 0 20 357 1100
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA www.cisco.com
Tel: 408 526-7660
Fax: 408 527-0883
Asia Pacific Headquarters
Cisco Systems, Inc.
Capital Tower
168 Robinson Road
#22-01 to #29-01
Singapore 068912 www.cisco.com
Tel: +65 317 7777
Fax: +65 317 7799
Cisco Systems has more than 200 offices in the following countries and regions. Addresses, phone numbers, and fax numbers are listed on the
C i s c o W e b s i t e a t w w w . c i s c o . c o m / g o / o f f i c e s
Argentina • Australia • Austria • Belgium • Brazil • Bulgaria • Canada • Chile • China PRC • Colombia • Costa Rica • Croatia
Czech Republic • Denmark • Dubai, UAE • Finland • France • Germany • Greece • Hong Kong SAR • Hungary • India • Indonesia • Ireland
Israel • Italy • Japan • Korea • Luxembourg • Malaysia • Mexico • The Netherlands • New Zealand • Norway • Peru • Philippines • Poland
Portugal • Puerto Rico • Romania • Russia • Saudi Arabia • Scotland • Singapore • Slovakia • Slovenia • South Africa • Spain • Sweden
S w i t z e r l a n d • Ta i w a n • T h a i l a n d • Tu r k e y • U k r a i n e • U n i t e d K i n g d o m • U n i t e d S t a t e s • Ve n e z u e l a • Vi e t n a m • Z i m b a b w e
All contents are Copyright © 1992–2002, Cisco Systems, Inc. All rights reserved. CCIP, the Cisco Arrow logo, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Follow Me Browsing, FormShare,
Internet Quotient, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ logo, iQ Net Readiness Scorecard, Networking Academy, ScriptShare, SMARTnet, TransPath, and Voice LAN are trademarks of Cisco Systems,
Inc.; Changing the Way We Work, Live, Play, and Learn, Discover All That’s Possible, The Fastest Way to Increase Your Internet Quotient, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST,
BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo,
Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherSwitch, Fast Step, GigaStack, IOS, IP/TV, LightStream, MGX, MICA, the Networkers logo, Network Registrar, Packet, PIX, Post-Routing,
Pre-Routing, RateMUX, Registrar, SlideCast, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.
All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company.
(0206R)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Integration Description
- 1 Cisco Systems Hardware and Software Requirements
- 1 PBX Hardware and Software Requirements
- 1 Features Supported
- 1 Key Features Supported
- 1 Key Features Not Supported
- 1 Limitations
- 1 Calling Name and Number feature
- 1 User/Network Settings
- 2 Network Topology
- 2 Configuration
- 2 Configuringthe Siemens Hicom 300 E CS PBX
- 3 Siemens Hicom 330 E CS PBX Configuration Menus and Commands
- 11 Configuring the Cisco CallManager
- 13 Route Pattern Configuration
- 14 Test Results
- 15 Layer 1 (Physical Layer)
- 15 Layers 2 & 3 (Q.921 and Q.931)
- 15 User/Network Settings
- 17 Test Setup 2
- 18 Appendix A
- 19 Siemens Hicom 330 E CS Software release
- 20 Cisco 2621 Router Configuration