Survive All Catalog (Download PDF)

Survive All Catalog (Download PDF)
Survive-All™ Series
NEMA-4X Certified
for Harsh Environment Applications
Survive-All™ Series NEMA-4X Family
The industry standard for emergency lighting in harsh environments is here. Battery units,
remote fixtures, exit signage and combination units - Emergi-Lite® is proud to offer a complete
family of NEMA-4X Certified emergency lighting products that delivers impressive, state-ofthe-art illumination in a visually-appealing package.
A complete emergency lighting solution, these products are designed for use in a wide range
of commercial and industrial environments where humidity, dust, water infiltration, and the
risk of vandalism are specification criteria.
FEATURES
CERTIFICATIONS
APPLICATIONS
• Battery units and remotes
fixtures deliver unsurpassed
pathway illumination —
89 feet, center-to-center (see
photometric data on back cover)
•Fully gasketed enclosures
prevent water infiltration
•Vandal-resistant enclosures resist dents, peeling and
corrosion
•All units come with tamperproof screws and bits
•UV resistant enclosures
•Choice of colours - factory white,
black and grey
•Continuous self-diagnostic
monitoring and monthly selftesting
•Fully automatic, solid state
charger
•Non-intrusive magnetic test
switch
•Nexus® compatible
•CSA Certified for 30 minutes of
emergency operation
•Exit signs meet or exceed C22.2
No. 141
•NEMA-4X Certified for high
abuse areas, wet locations
and cold weather (-40°C)
applications
•NSF Certified for use in food
processing plants
•Hosedown areas/ car washes
•Food processing/ preparation
facilities
•Marine locations
•Chemical plants
•Schools and other public
facilities
•Parking garages
•Transit platforms
•Sports arenas/ swimming pools
•Security areas/ prisons
•Warehouse and cold storage
facilities
•Heavy industrial facilities
NEMA-4X
2
Emergency lighting products for harsh
environment applications
EN Series
ENC Series
•Sealed heavy-duty, vandal-resistant polycarbonate
faceplate
•Suitable for cold weather application —
-40°C (AC/DC model) and -25°C on self-powered
model (CW option)
•Energy efficient - consumes less than 2.5W in AC or
DC mode Survive-All™ EN Series
•Same product with exit legend also available
•Innovative, field-adjustable lamp head assembly
•Choice of MR16 halogen lamps up to 12V, 12W or
high-efficiency, 6W, MR16 LED lamps
•Can be wall or ceiling mounted
•Double face available
•Suitable for cold weather application —
-40°C (CW option) - Available in 6V only.
•Same product with exit legend also available
NEMA-4X & NSF Certified Combination Unit
NEMA-4X & NSF Certified Pictogram Sign
UNRIVALLED PATHWAY ILLUMINATION
89 FEET CENTER-TO-CENTER
(see photometric data on the last page)
Survive-All™ NXM Series
Survive-All™ EF39 Series
•Fully gasketed cast aluminium back plate with clear
UV resistant polycarbonate cover
•Long-life maintenance-free sealed Lead-Acid battery
•Choice of MR16 halogen lamps up to 12V, 20W or
high-efficiency, 6W, MR16 LED lamps
•Mounting: wall mount
•Unit capacity: up to 108W
•Suitable for cold weather application —
-40°C (CW option)
•Choice of single or double head models
•Fully gasketed cast aluminium or polycarbonate back
plate with clear UV resistant poly carbonate cover
•Choice of MR16 halogen lamps up to 24V, 20W or
high-efficiency, 6W, MR16 LED lamps
NEMA-4X Certified Battery Unit
NEMA-4X Certified Remote Fixtures
3
Survive-All™
EN Series
Project/Location:
Contractor:
Date:
NEMA-4X & NSF Certified
Pictogram Sign
FEATURES
• NEMA-4X Certified
• NSF compliant for food processing
• Polymeric enclosure is fully gasketed around lens and canopy to
secure against water leaks
• Sealed, heavy-duty, vandal-resistant polycarbonate face plate
• Suitable for cold weather: -40°C for AC/DC and -20°C for
Self-Powered models (option: -CW)
• Tamper-resistant, concealed test switch with magnetic action
• White LED light source
• Supplied standard with two pictogram films per face, for direction
selection
• Meets or exceeds CSA 22.2 No.141-10 standard for pictogram
Exit Signs
• Universal AC input: two-wire 120 to 347VAC; Standard DC input:
two-wire 6 to 24VDC
• Energy efficient – consumes less than 2.5W in AC or DC-remote
mode
• Self-Powered models deliver two hours of back-up lighting
NEMA-4X
DIMENSIONS
TYPICAL SPECIFICATIONS
Supply and install the Emergi-Lite® Survive-All™ EN Series pictogram
Exit Signs. The equipment shall be certified for NEMA- 4X and
designed specifically for high abuse areas, wet locations, and cold
weather applications. The equipment frame shall be of industrial
grade polyvinyl chloride with a gasket around lenses and canopy.
The faceplate(s) shall be constructed of heavy-duty vandal-resistant
polycarbonate and feature an even illuminated legend. Each face plate
shall come standard with two legend films for pictogram and direction
selection. The light source shall be white light-emitting diodes (LED).
The pictogram Exit Sign shall operate with universal 2-wire AC input
voltage of 120 to 347VAC at less than 2.5W and universal 2-wire DC
input voltage from 6 to 24VDC at less than 1W for single and double
face signs. The Self-Powered model shall include a concealed green
pilot light and magnet-sensitive test switch, shall use a sealed
Nickel-Cadmium battery of 2.4V nominal voltage and shall stay
illuminated during emergency operation for at least two hours upon
AC failure. When specified, the Self-Powered model shall include
auto-test functions: it shall execute automatic tests for 5 minutes every
30 days, 30 minutes every 60 days and two hours annually. When a fault
is detected, the bi-colour pilot light shall turn from green to red and
flash following a particular code. The code description shall be visible
on a label next to the pilot light to identify the failure type: battery,
charger circuitry, or LED lamps.
The pictogram Exit Sign shall be listed CSA 22.2 No.141-10 standard.
Dimensions are approximate and subject to change.
The equipment shall be Emergi-Lite® Model:
< PICTOGRAM
LEFT FROM HERE
14” [35.7 cm]
131/4” [33.6 cm]
POWER CONSUMPTION AND UNIT RATING
MODEL
31/2” [8.7 cm]
37/8” [9.9 cm]
91/4” [23.4 cm]
PICTOGRAM >
RIGHT FROM HERE
DOUBLE FACE
SURVIVE-ALL™ NEMA 4X & NSF CERTIFIED FAMILY
P. 64
LPEX600-N
SERIES
SERIES
P. 63
P. 65
AC/DC standard
AC/Special DC
SINGLE FACE
LPEX600
NXM SERIES
P.120-121
EF39 & EF39P
EN= NEMA-4X
& NSF
pictogram
exit sign
FACES/ MOUNTING
120VAC
Self-Powered
120 to
347VAC
Auto test
120 / 347VAC
DC SPECS
Less than
2.5W
Less than
2.5W
Less than
2.5W
Less than
2.5W
Less than
3W
Nickel-Cadmium
battery
Less than
1W
Less than
2.5W
Less than
2.5W
Min. 2
hours
Less than
3.5W
Nickel-Cadmium
battery
Min. 2
hours
6 to 24VDC
36, 48, 120VDC
120VDC
-
WIRE GUARDS
SERIES
460.0079-E
P.148-149
460.0027-E
End mount
460.0028-E
Ceiling mount
COLOUR
1= single face universal B= black
mounting
W= factory
2= double face
white
universal mounting
120 to
347VAC
120 to
347VAC
120 to
347VAC
Two-wire 120V
AC/DC
ORDERING INFORMATION
SERIES
AC SPECS
AC-only
PICTOGRAM
STRAIGHT FROM
HERE
ENC SERIES
Prepared by:
VOLTAGE
I= self-powered, 120 to 347VAC
ID= self-powered diagnostic NiCad, 120 to 347VAC
ID2= self-powered diagnostic NiCad, 120 to 277VAC
U= universal, 120 to 347VAC; 6 to 24VDC
U00= 120 to 347VAC only
U36= 120 to 347VAC; 36VDC
U48= 120 to 347VAC; 48VDC
U120= 120 to 347VAC; 120VDC
EM120-2W= 2-wires 120VAC/VDC
NEX= NEXUS® system interface, 120/347VAC
NEX2= NEXUS® system interface, 120/277VAC
NEXRF= NEXUS® system interface, 120/347VAC
NEXRF2= NEXUS® system interface, 120/277VAC
EXAMPLE: EN1WICW
664
Wall mount
OPTIONS
Blank= no options
CW= cold-weather (-20°C for ID,
ID2 and NEXUS® only)
Survive-All™
ENC Series
Project/Location:
Contractor:
Date:
NEMA-4X & NSF Certified
Pictogram Combination Unit
Prepared by:
FEATURES
• Certified NEMA-4X for wall or ceiling mount
• NSF certified certified for use in food processing areas
• Meets or exceeds CSA 22.2 No.141-10 standard for pictogram
Exit Signs
• Polyvinyl chloride frame, with built-in gasket to prevent water
infiltration
• Sealed, vandal-resistant faceplate of polycarbonate
• Legend illuminated by long-life white LED’s
• Comes standard with two pictogram films per face, for direction
selection
• Two high-performance MR16 LED lamps shielded by a clear
polycarbonate cover
• O ptional 5W LED emergency lights provide 60’ of egress
illumination on a 6-foot wide path
• Sealed, maintenance-free Lead-Calcium or Nickel-Cadmium
batteries
• Remote load capacity: covers with 4W LED lights 100’ up to 230’ of
egress illumination
• Comes standard with auto-diagnostic
• Cold-weather option: -40°C (-40°F) with only 14W extra power
consumption
NEMA-4X
DIMENSIONS
Dimensions are approximate and subject to change.
POWER CONSUMPTION
14” [35.7 cm]
37/8” [9.9 cm]
131/4” [33.6 cm]
PICTOGRAM
STRAIGHT FROM HERE
31/2” [8.7 cm]
MODEL
91/4” [23.4 cm]
125/8” [32.1 cm]
< PICTOGRAM
LEFT FROM HERE
TYPICAL SPECIFICATIONS
Supply and install Emergi-Lite® Survive-All™ ENC Series combination
emergency light battery unit and pictogram Exit Sign. Designed
specifically for industrial environments, the equipment frame shall be
of industrial grade polyvinyl chloride with gaskets around both sides of
frame contour. The back plate shall be made of 1/8” thick aluminum
sheet and shall include knock-outs for installation on an electrical box.
The faceplate(s) shall be constructed of heavy-duty vandal-resistant
clear polycarbonate and feature a uniformly illuminated pictogram
legend. Each face plate shall come standard with two legend films for
pictogram and direction selection. The light source shall be long-life
white light-emitting diodes (LED). The unit shall have attached a lower
compartment containing two emergency heads with adjustable swivels
and long-life MR-16 LED lamps of ___ V and ___ W. The heads shall be
installed on a shield housing made of rigid thermoplastic and shall be
protected by a shock-absorbent, clear polycarbonate cover. The standard
AC input voltage shall be 120/347VAC. The unit shall be equipped with
a magnetic test switch and an LED pilot light protected by the clear
face plate. The unit shall perform auto-test functions managed by a
micro-controller and shall automatically self-test for one minute every 30
days, 10 minutes in the 6th month and 30 minutes annually. When a fault
is detected, the bi-colour pilot light shall turn from green to red and flash
following a particular code. The code description shall be displayed on
a label next to the pilot light to identify the failure type: battery, charger
circuitry, LED lights for the signage, or emergency lights.
The combination unit shall meet or exceed the standard CSA C22.2
No.141-10. The equipment shall be Emergi-Lite® Model:
EMERGENCY POWER FOR
LAMPS
AC SPECS
30MIN 1H00 1H30 2H00 4H00
Pictogram
120/347VAC
Sign Module
ENC-6L36
PICTOGRAM >
RIGHT FROM HERE
DOUBLE FACE
SINGLE FACE
SURVIVE-ALL™ NEMA 4X & NSF CERTIFIED FAMILY
ENC6L36-CW
ENC-6N36
ENC6N36-CW
ENC-12N60
120/347VAC
Less than
2.5W
-
-
-
-
-
0.10/0.03 A
36
21
15
12
-
0.25/0.08 A
36
21
15
12
-
0.10/0.03 A
36
30
20
16
8
0.25/0.08 A
36
30
20
16
8
0.18/ 0.06 A
60
40
30
20
10
WIRE GUARDS WITH HEADS
EN SERIES
LPEX600 SERIES
LPEX600-N
NXM SERIES
SERIES
P. 62
P. 63
460.0078-E
460.0060-E
EF39 & EF39P
SERIES
P. 65
P.120-121
Wall Mount
End or Ceiling Mount
P.148-149
ORDERING INFORMATION
SERIES
ENC= NEMA-4X
& NSF
pictogram
exit
combo
unit
FACES /
MOUNTING*
HOUSING
COLOUR
BATTERY TYPE AND
POWER
HEAD STYLE AND
WATTAGE
OPTIONS
1= single face
2= double face
B= black
W= factory
white
6N36= 6V-36W
Nickel-Cadmium
12N60= 12V-60W
Nickel-Cadmium
Blank= no heads
LA= MR16 LED, 6V-4W
LG= MR16 LED, 12V-4W
LI= MR16 LED, 12V-5W
LJ= MR16 LED, 12V-6W
MI= MR16 halogen, 6V-6W
MJ= MR16 halogen, 6V-10W
MK= MR16 halogen, 12V-12W
Blank= advanced diagnostic, non-audible (standard)
-2= 120/277VAC input
D3= time delay (15 minutes)
NEX= NEXUS® system interface*
NEXRF= w
ireless NEXUS® system interface*
CW= c old-weather -40°C (-40°F) to + 25°C (77°F)
only with 6V single-face units
U= advanced diagnostic
*Universal
mounting
EXAMPLE: ENC2W12N60LD7
5
*Some options are not available with NEXUS®.
Project/Location:
Survive-All™ NXM
Series
Contractor:
Date:
Prepared by:
NEMA-4X Certified
TYPICAL SPECIFICATIONS
FEATURES
• Fully gasketed cast aluminum back plate with clear
polycarbonate cover – NEMA-4X Certified
Supply and install the Emergi-Lite® NEMA-4X Certified
Survive-All™ NXM Series battery unit. Specifically designed for high
abuse areas, wet locations, and cold weather (CW option -40°C
(-40°F)), the housing shall consist of a fully gasketed Die-Cast with
a cast aluminum back plate and a clear heavy-duty UV resistant
polycarbonate cover. The heads shall be fully adjustable without
tools and the lamps shall be high efficiency halogen MR16. The
standard unit shall be equipped with tamper-proof screws and bits.
The Emergi-Lite® Advanced Diagnostic Micro-controller charger
board shall supply the rated load for a minimum of 30 minutes to
87.5% of the rated battery voltage. The charger incorporates lockout
and brownout circuits, and low voltage disconnection. It protects the
unit from over-current, short-circuit, and reverse polarity. The unit
shall be rated 120/347V, 60Hz. The unit shall have an output of
V. This unit shall self-test for 1 minute every 30 days, 10 minutes
every 6 months and 30 minutes every 12 months. The unit shall
be furnished with a non-intrusive magnetic test switch. A “Service
Required” lamp shall be located near the test switch and flash when
a fault is detected. A four-LED diagnostic display shall be located
inside the equipment and shall identify the source of failure (battery,
charger, circuitry, or lamps).
• Comes standard with non-audible advanced diagnostic,
10 minutes time delay and lamp disconnect
• Audible warning and time delay functions can be enabled
or disabled during installation
• Micro-controller diagnostic system tests, detects and
indicates battery, charger circuitry or MR16 lamp failures
• Non-intrusive magnetic test switch
• Long-life, maintenance-free sealed lead-acid battery
• 1/2” rigid conduit entry on top and back
• Can be installed on 4” junction boxes
• Comes standard with tamper-proof screws and bit
• Cold weather option -40ºC (-40ºF)
• NSF Certified for food processing plants
• CSA C22.2 No. 141 Certified
• NEXUS® compatible
The unit shall be Emergi-Lite® model:
• Standard 120/347VAC input voltage
WIRE GUARDS
460.0031-E
Wall Mount
REPLACEMENT LAMPS
NEMA-4X
ORDERING CODE
LAMP TYPE
VOLTAGE/ WATTAGE
580.0074-E
MR16 halogen
6V-6W
580.0079-E
MR16 halogen
6V-10W
580.0080-E
MR16 halogen
12V-12W
580.0064-E
MR16 halogen
12V-20W
580.0104-E
MR16 LED
12V-5W
580.0097-E
MR16 LED
6V-4W
580.0106-E
MR16 LED
12V-6W
SURVIVE-ALL™ NEMA 4X & NSF CERTIFIED FAMILY
120
6
ENC SERIES
LPEX600
SERIES
LPEX600-N
SERIES
EN SERIES
EF39 SERIES
P. 62
P. 61
P. 63
P.112-113
P.136
Project/Location:
Survive-All™ NXM
Series
Contractor:
Date:
Prepared by:
NEMA-4X Certified
DIMENSIONS
Dimensions are approximate and subject to change.
53/4” [14.6 cm]
173/4” [45.1 cm]
7” [17.8 cm]
PMK KIT
(SCREWS INCLUDED)
SUPERSTRUT
MOUNTING
BEAM MOUNTING
POWER CONSUMPTION AND UNIT RATING
MODEL
WATTAGE CAPACITY
AC SPECS
30MIN
1H00
1H30
2H00
4H00
06NXM36
0.15/0.06 A
36
21
15
12
6
12NXM72
0.25/0.10 A
72
42
30
24
12
0.25/0.10 A
108
63
45
36
18
0.45/0.20 A
36
-
-
-
-
0.85 A
72/108
-
-
-
-
120/347VAC
12NXM108
Cold Weather 36W
Cold Weather 72/108W
120VAC
*Note: capacity depends on the ambient temperature
ORDERING INFORMATION
SERIES
06NXM= 6V,
NEMA-4X
12NXM= 12V,
NEMA-4X
COLOUR
W= white
B= black
G= grey
CAPACITY
36= 6V-36W
72= 12V-72W
108= 12V-108W
VOLTAGE
Blank= 120/347VAC
2= 277VAC
OPTIONS
Blank= no options
CW1= cold weather 120VAC
CW3= cold weather 347VAC*
NEX= NEXUS® system
interface**
NEXRF= wireless NEXUS®
system interface**
PMK-E= universal bracket (sold
separetely)
690.0454-E= additional-bit for
tamper-proof
screws (sold
separately)
# OF HEADS
/2= 2 heads
LAMP
LA= MR16 LED,
6V-4W*
LG= MR16 LED,
12V-4W*
LI= MR16 LED,
12V-5W
LJ= MR16 LED,
12V-6W
MI= MR16, 6V-6W
MJ= MR16, 6V-10W
MK= MR16,
12V-12W
MG= MR16,
12V-20W*
MW= MR16-IR,
12V-20W
*Available in 6V only.
**Consult your sales representative for
options available with the NEXUS®
system.
EXAMPLE: 06NXMW36/2MI
7121
*Minimum lamp load
required: 20% of unit
capacity
Survive-All EF39
& EF39P Series
Project/Location:
™
Contractor:
Date:
NEMA-4X Certified Remote Fixture
FEATURES
Prepared by:
TYPICAL SPECIFICATIONS
• Fully gasketed with a selection of cast aluminum or
polycarbonate back plate
Supply and install Emergi-Lite® EF39P Series remote emergency
lighting fixtures. These remote fixtures will consist of either
single or double lamp configurations according to the design.
These fixtures shall be fully gasketed with a UV resistant and fire
retardant polycarbonate back plate with a clear heavy-duty UV
resistant polycarbonate lens. The unit shall be equipped with two
emergency heads with tool-less adjustable swivels (lamps of 12W
or less). Units shall be NEMA-4X and NSF certified and specifically
designed for high abuse areas, wet and cold weather locations, food
processing plants, as well in applications requiring a resistance to
corrosive agents. The standard unit will come with stainless steel
tamper-proof screws and bit.
The remote fixture shall be certified to CSA C22.2 No. 141. The
head(s) shall be fully adjustable without tools and should be
V
W.
equipped with MR16 halogen lamp(s) of
The remote unit shall be the Emergi-Lite® model:
.
• Clear polycarbonate UV and impact resistant lens
• Choice of single or double lamp models
• Available in 6, 12 and 24V models MR16 or LED
• Easy lamp replacement
• Comes standard with tamper-proof screws and bit
• NSF Certified for food processing plants
• NEMA-4X Certified*
• CSA Certified to C22.2 No. 141
• Suitable for indoor/outdoor installation
* For EF39P, units are NEMA-4X Certified when installed using a circular NEMA-4X rated
junction box (sold seperatly by Thomas&Betts under P/N CE365D-CAR or
CE365DW-CAR and with plugs P/N P7701W-CAR).
REPLACEMENT LAMPS: MR16
EF39P
ORDERING CODE
NEMA-4X
LAMP TYPE
VOLTAGE
580.0074-E
MR16 flood
6V-6W
580.0079-E
MR16 flood
6V-10W
580.0080-E
MR16 flood
12V-12W
580.0070-E
MR16 flood
24V-12W
580.0097-E
MR16 LED
6V-4W
580.0093-E
MR16 LED
12V-4W
580.0104-E
MR16 LED
12V-5W
580.0106-E
MR16 LED
12V-6W
580.0098-E
MR16 LED
24V-4W
For the complete list, please see the lamp chart on pages 156 to 158
EF39
148
8
ORDERING CODE
LAMP TYPE
VOLTAGE
580.0068-E
MR16 IR flood
12V-20W
580.0077-E
MR16 flood
24V-20W
580.0100-E
MR16 LED
24V-6W
Survive-All™ EF39
& EF39P Series
Project/Location:
Contractor:
Date:
NEMA-4X Certified Remote Fixture
Prepared by:
DIMENSIONS
Dimensions are approximate and subject to change.
73/8” [18.7 cm]
47/8” [12.3 cm]
33/4” [9.5 cm]
ORDERING INFORMATION: EF39P
SERIES
EF39P= polycarbonate
NEMA 4X back
plate
NUMBER OF LAMPS
Blank= one lamp
D= two lamps
LAMP TYPE
M= MR16
COLOUR
Blank= factory
white
-B= black
-G= grey
LAMP TYPE/VOLTAGE/WATTAGE
-LA= MR16 LED, 6V-4W
-LG= MR16 LED, 12V-4W
-LI= MR16 LED, 12V-5W
-LJ= MR16 LED, 12V-6W
-LL= MR16 LED, 24V-4W
-6V6W= MR16 halogen, 6V-6W
-6V10W= MR16 halogen, 6V-10W
-12V12W= MR16 halogen, 12V-12W
-24V12W= MR16 halogen, 24V -12W
OPTIONS
-SM= surface mount*
* surface plastic junction box
included
EXAMPLE: EF39PDM-B-6V6W
ORDERING INFORMATION: EF39
SERIES
EF39= die-cast NEMA 4X
back plate
NUMBER OF LAMPS
Blank= one lamp
D= two lamps
LAMP TYPE
M= MR16
COLOUR
Blank= factory white
-B= Black
-G= grey
EXAMPLE: EF39DM-12V20W
149
9
LAMP TYPE/VOLTAGE/WATTAGE
-12V20W= MR16-IR, 12V-20W, high output
-24V20W= MR16 halogen, 24V-20W
-LM= MR16 LED, 24V-6W
PHOTOMETRICS
The Emergi-Lite® NEMA-4X Series of emergency lighting sets an impressive new standard for
center-to-center path of egress illumination. Battery units and fixtures illuminate an egress path
89-feet long and 6-feet-wide.
Photometric data based on a 7-foot mounting height, minimum 80-50-20 reflectance values and 12V-6W MR16 LED lamps.
3D image showing installation of two NXM Series battery units
and a ENC combination unit in an industrial application under
normal lighting conditions.
3D image lighting rendering showing installation of two NXM
Series battery units and a ENC combination unit in an industrial
application under emergency lighting conditions.
1FC a
verag
e
7.5’
70’
6’
3D light level coloured scale image showing egress illumination
pattern generated by two NXM battery units and a ENC combination
unit.
ISO curve on a point-by-point of two NXM Series battery units.
NOTE: Photometric results shown are based on a simulation using the AGI32 software with a 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum-minimum ratio.
Emergi-Lite® assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not a guarantee of any code compliances.
10
www.emergi-lite.ca
All information and specifications contained in this flyer are subject to change due to engineer design, errors and omissions.
Illustrations and diagrams within this flyer may vary from actual products.
© 2016. Thomas&Betts Limited. All rights reserved. Printed in Canada. 03/2016
Order No.: EL/NEMA4X-E
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement