American Standard R510.000 Ceratherm Central Thermostat Installation Instructions
Add to my manuals3 Pages
American Standard R510.000 is a thermostatic shower valve that provides precise temperature control and safety features for a comfortable showering experience. With its versatile design, it can be used for various shower configurations, including a single on/off valve with a fixed shower, two on/off valves with a fixed shower and adjustable handheld shower, or three on/off valves with a fixed shower, adjustable handheld shower, and two body sprays. The temperature limit stop allows you to set a maximum water temperature for added safety, especially for families with young children.
advertisement
Installation
Instructions
R510
R530
ROUGH VALVE KIT
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
TOP
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1 ASSE 1016
M 9 6 8 2 5 6 R E V. 1. 4 ( 12 / 14 )
ROUGHING-IN DIMENSIONS
1/2" NPT OUTLETS FOR R510
3/4" NPT OUTLETS FOR R530
5-7/8"
1/2" NPT OUTLETS FOR R510
3/4" NPT OUTLETS FOR R530
32" TO 42"
FOR BATH/SHOWER
AND BATH FILLER
(OPTIONAL)
THERMOSTATIC SHOWER
INSTALLATION USING ONE
ON/OFF VALVE AND FIXED
SHOWER
3-3/8"
FINISHED FLOOR
48" TO 54"
FOR SHOWER ONLY
(OPTIONAL)
CL
2 to 2-5/8"
FINISHED
WALL
THERMOSTATIC SHOWER INSTALLATION
USING TWO ON/OFF VALVES, FIXED
SHOWER AND ADJUSTABLE HAND
HELD SHOWER
(2) On/Off
Volume
Control Valves
THERMOSTATIC SHOWER INSTALLATION
USING THREE ON/OFF VALVES, FIXED
SHOWER, ADJUSTABLE HAND HELD
SHOWER AND TWO BODY SPRAYS
(3) On/Off
Volume
Control Valves
On/Off
Volume
Control Valve
HOT
1/2" or 3/4" inlet
TUB PORT MUST
BE PLUGGED
COLD
1/2" or 3/4" inlet
INLET AND OUTLET CONNECTIONS ARE
1/2" NPT FOR R510
INLET AND OUTLET CONNECTIONS ARE
3/4" NPT FOR R530
HOT
1/2" or 3/4" inlet
TUB PORT MUST
BE PLUGGED
COLD
1/2" or 3/4" inlet
INLET AND OUTLET CONNECTIONS ARE
1/2" NPT FOR R510
INLET AND OUTLET CONNECTIONS ARE
3/4" NPT FOR R530
HOT
1/2" or 3/4" inlet
3/4"
COLD
1/2" or 3/4" inlet
TUB PORT MUST
BE PLUGGED
INLET AND OUTLET CONNECTIONS ARE
1/2" NPT FOR R510
INLET AND OUTLET CONNECTIONS ARE
3/4" NPT FOR R530
NOTE: TO OPERATE ALL FOUR OUTLETS AT THE SAME
TIME THE MINIMUM REQUIREMENTS ARE:
FLOWING PRESSURE OF 40 PSI WITH R510
FLOWING PRESSURE OF 20 PSI WITH R530
1 ROUGHING-IN THE VALVE
CAUTION
Turn off hot and cold water supplies before beginning.
2
Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between the minimum 1-11/16" and maximum 2-1/2" rough dimension.
Install VALVE (1) at indicated height and depth. Make sure the "TOP" marking on the PLASTER
GUARD (2) is up. For support, use pipe BRACES (3) secured to wooden braces.
Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to remove any dirt. Connections are 1/2" NPT or 3/4" NPT.
IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVE INTO THE PIPING SYSTEM.
WARNING
DO NOT SOLDER DIRECTLY TO THE VALVE BODY (1); THIS WILL DAMAGE
THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES.
If the CHECK STOPS (4, 5) were removed during installation, ensure the hot and cold
CHECK STOPS (4, 5) are not reversed. The hot CHECK STOP (4) has a red top and the cold
CHECK STOP (5) has a blue top.
CHECK STOPS (4,5) are supplied in the open position. Closing using 5/32" (4 mm) hex wrench to pressure test and to check for leaks.
HOT
To flush lines, remove the CHECK STOPS (4,5) and run water. If desired, the TEMPERATURE CONTROL UNIT can be removed. Reinstall CHECK STOPS (4,5) and CONTROL UNIT (6), if it was removed.
Remove PLASTER GUARD (2) if still installed. Turn on water supplies and check for leaks.
Reassemble PLASTER GUARD (2) and FINISH WALL.
Beware of Freezing. No water should remain in the MIXING VALVE if freezing is a possibility.
Remove the CHECK STOPS (4,5) to completely drain the MIXER UNIT (1).
1
TRANSPOSED SUPPLY PIPING
OR BACK TO BACK INSTALLATION
WOOD BRACE
Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:
Shut off water supply.
Remove handle and rim
Remove check stops and re-install them transposed.
Important note: RED CHECK
STOP is now on the right of the mixer body and the BLUE
CHECK STOP is now on the left.
HOT
3
PLUG TUB PORT
(DO NOT REMOVE)
CHECK STOP
(HOT RED)
4
6
2
Turn the water supply back on and perform the temperature adjustment in step 3.
CHECK STOP
(RED TO BLUE) CHECK STOP
(BLUE TO RED)
3
TEMPERATURE CALIBRATION
ARROW
"B"
Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall
KNOB MOUNT with arrow "B" pointing upwards.
The maximum mixed water temperature is set at 109 F at the factory.
This setting can be changed if desired.
TEMPERATURE
LIMIT STOP 104
109
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE.
Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve.
112
SECURING
RING
RED LOCKING
DEVICE
Reinstall the KNOB MOUNT so that the arrow marking A points upwards. Reinstall RED LOCKING DEVICE.
4
OPERATING PROCEDURE
COLD
5
COLD
TOP
CHECK STOP
(COLD BLUE)
BLACK
CLAMP
ARROW
"A"
TOP
KNOB
MOUNT
Place temperature handle in the middle position between the extreme hot and cold positions.
TO PREVENT DAMAGE TO THE TEMPERATURE HANDLE ASSEMBLY, DO NOT FORCE HANDLE TO THE EXTREME HOT OR COLD POSITIONS.
Adjust temperature handle (bottom handle, R540 Type Rough Valves) to the desired temperature position. Turn temperature handle in the extreme left or right positions.
Temperature handle should remain in last position for next use to ensure that desired, set temperature is achieved.
M 9 6 8 2 5 6 R E V. 1. 4 ( 12 / 14 )
953950-0070A
CHECK STOP R510
(COLD BLUE)
A953971-0070A
CHECK STOP R530
(COLD BLUE)
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
MODEL NUMBERS
R510
R530
953951-0070A
CHECK STOP R510
(HOT RED)
A953972-0070A
CHECK STOP R530
(HOT RED)
9 6 3 4 3 4 - 0 0 2 0 A D E E P R O U G H K I T
S O L D S E PA R AT E LY
912647-0070A
O-RING
A955585-0070A
THERMOSTAT CARTRIDGE
R510
954040-0070A
THERMOSTAT CARTRIDGE
R530
953963-0070A
HANDLE
EXTENSION
953957-0070A
TEMPERATURE
CALIBRATION
UNIT
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
© AS America,Inc. 2008 M 9 6 8 2 5 6 R E V. 1. 4 ( 12 / 14 )