Green Energy Sensor–enabled eco PDU
Our Vision
“Simply Better Connections” has always been at the heart of the ATEN brand. It means providing innovative solutions for you to make
better connections, efficiently and seamlessly, to the information and people that you value. As a result, ATEN connects you to the world,
anytime and anywhere, by providing technologies that enable you to share and to care. ATEN makes professional and personal life easier,
simpler and better connected.
About ATEN
ATEN, established in 1979, specializes in connectivity management solutions for accessing and sharing technologies. ATEN consolidates
all of its products under the ATEN brand to provide a standard of consistent service under one name. The ATEN brand consists of
innovative solutions applied to IT infrastructure access management, professional audio/video, and green energy products for
consumers, small/home offices (SOHO), small to medium sized business (SMB) and enterprise customers.
ATEN’s Altusen™ IT infrastructure access management solutions offer connectivity and control capabilities for SMB and Enterprise
customers that allow people to effectively manage IT equipment from anywhere in the world. ATEN’s VanCryst™ professional audio/video
solutions offer signal management and system control for home and professional audio/video installations with a variety of applications
in corporate, education, government, hospitality and home theater environments. ATEN’s NRGence™ Green Energy line offers sensorenabled energy-saving hardware and software solutions for the data center with a range of intelligent power and cooling distribution
units that provide real-time energy management and performance indicators locally and remotely.
ATEN specializes in connectivity and management solutions. We distribute our products through a global sales network to meet a broad
range of customer needs. ATEN delivers with quality and we care about our customers. We are committed to the best customer support
in the industry.
ATEN NRGence™ Energy Intelligence PDUs for Data Centers
At ATEN we are committed to offering real solutions for data centers, to this end, ATEN’s NRGence™ Green Energy solutions offer the
latest in energy intelligence. Our solutions for data centers begin with a wide range of eco PDUs, developed to support ISO50001, that
take intelligence to the next level by providing real-time energy management, control and energy-saving efficiency by allowing you to
easily upgrade current IT resources quickly and cost effectively.
As PDU experts we have developed a variety of standardized and modularized rack PDUs in both 1U and 0U types to suit most data
centers. As PDU experts we understand that some data centers have requirements that can’t be met effectively with “off the shelf models”,
therefore we also offer customers a BTC “Build to Configuration” service to construct PDUs according to their individual requirements,
effectively providing the ideal power solution.
ATEN’s dedicated PDU team offers professional solutions in developing energy efficiency. Only with accurate measurements and data can
data centers develop effective strategies and employ effective technologies for energy reduction.
ATEN delivers and we care about our customers. We are committed to the best customer support in the industry.
PDU Comparison
Features
Model
Rack Space
Outlet
PE5
PE6
PE7
PE8
PE6
PE7
PE8
PE9
PE8216
PE8324
PE9216/PE9222
PE9324/PE9330
PE6108
PE6208
PE7108
PE7208
PE8108
PE8208
1U
1U
1U
1U
0U
0U
0U
0U
0U
0U
8
8
8
8
16/20, 24/40
16/20, 24/40
16/24
14/16, 24/28
16/24
16/22, 24/30
•
•
•
Bank, PDU Level
Bank, PDU
Level
Outlet, Bank,
PDU Level
Outlet,
Bank, PDU
Level
Outlet, Bank,
PDU Level
•
•
•
•
•
•
•
•
•
•
•
•
•
•
PDU Level
PDU Level
Outlet,
PDU Level
Outlet,
PDU Level
Environment
Monitoring
•
•
•
•
eco Sensors Support
•
•
•
•
Proactive Overload
Protection
PE5
PE5216/PE5220s
PE1216/PE2220
PE6216/PE6324 PE7214/PE7216
PE5324/PE5340s
PE1324/PE2340
PE6324L
PE7324/PE7328
PE5324L/PE5340SL
PE5108
PE5208
Remote Power Control
Metering Capability
PE1/PE2
•
Bank Via
EC1000/
EC2004
Via EC1000/
EC2004
Via EC1000/
EC2004
•
•
Critical Load Outlet
Door Sensor
•
Via EC2004
•
•
•
4 Powerful Reasons to use ATEN's
Green Energy Solutions
In the last decade, data center infrastructure management (DCIM) has grown to become a hot issue all over the world. No matter
what market you are in, the need for energy saving and optimizing power has hit your sector. It’s the goods everyone needs to
run a smart business. But not everyone has the tools or know-how to rein in this over-tolling expense. The first thing you need is
a good measurement of power consumption. ATEN’s Green Energy Solutions provide just that with the latest energy intelligence
software and hardware to supply the power and take perfect measurements of the consumption. ATEN energy saving PDU’s
can measure power at the PDU, bank and outlet level, plus provide accurate readings of the room’s temperature, humidity and
differential pressure. All data is maintained by our eco Sensors software which provides real-time information and detailed
reports of energy usage and the environment. ATEN PDUs give you the tools and know-how to make better decisions for power
allocation in any data center.
Since ATEN begun producing green energy PDUs a diverse range of industries including Education, Government, Transportation,
Enterprise and medium size businesses around the world have successfully adopted NRGence™ Green Energy solutions. Below we
highlight some of the reasons why.
Remote Power Outlet Control
ATEN PE6/PE8/PE9 eco PDUs allow administrators to remotely control the power of all servers in a
data center. Administrators can remotely access any individual outlet and outlet groups to manage
power (On/Off, PowerCycle) through an easy-to-use web interface.
Real-Time Monitoring
Using ATEN eco Sensors Energy Management Software, administrators can remotely monitor the
current, voltage, kWH, power consumption and circuit breaker status of all connected devices in realtime. In addition, the software can track the temperature and humidity via sensors connected to the
PDU and provide a complete comprehensive report of all the data being monitored.
Proactive Overload Protection (POP)
ATEN’s exclusive POP feature automatically powers off outlets in the event of a current overload to
protect the other connected devices from being shut down unexpectedly.
Power Analysis Report
ATEN’s eco Sensors software provides power analysis report for optimizing data center energy
management – including power usage, power load, power cost, CO2 cost, power capacity and
trends. In addition it offers essential data center indices including Rack Intake Temperature, Rack
Exhaust Temperature, Rack Equipment Temperature Difference, RCI (Rack Cooling Index), RTI (Return
Temperature Index), RHI (Rack Humidity Index), RPI (Rack Pressure Index), and RAI (Rack Airflow
Index).
ATEN’s Exclusive POP Provides the Most Secure
and Reliable Power Distribution
ATEN‘s Proactive Overload Protection (POP) empowers users to prioritize their data center’s power distribution. When the current
overloads, POP will automatically power off outlets to protect IT servers from shutting down unexpectedly. There are 2 POP
options available for selection - LIFO Mode and Priority Mode.
LIFO Mode :
The last powered on outlet will automatically power off.
POP Settings
Enable POP LIFO Mode
Enable POP Prioity Mode
Priority Mode :
Outlets will power off following a pre-defined order. Administrators can set the shutdown priority of each outlet via web browser.
Bank 1 Priority Mode
Bank 2 Priority Mode
Priority 1
Outlet 18
Priority 1
Outlet 18
Priority 2
Outlet 22
Priority 2
Outlet 22
Priority 3
Outlet 19
Priority 3
Outlet 19
Priority 4
Outlet 21
Priority 4
Outlet 21
Priority 5
Outlet 20
Priority 5
Outlet 20
Priority 6
Outlet 23
Priority 6
Outlet 23
Priority 7
Outlet 17
Priority 7
Outlet 17
Priority 8
Outlet 24
Priority 8
Outlet 24
When a power overloading condition is detected....
With POP Protection
ATEN POP PDU
(PE6, PE8 and PE9 Series)
Without POP Protection
Other PDUs
Without ATEN’s POP, PDUs will cut off the entire circuit when the power is overloaded, resulting in a sudden shut down of all
equipment – which can include lighting, air conditioning and servers.
Note: ATEN's PE8/PE9 series support full POP functionality, while the PE6 series only provides Priority Mode.
How can POP protect your IT equipment ?
Scenario : Power Consumption Suddenly Rises and Causes Power Overload
Setting A
Enable POP LIFO Mode
Enable POP Prioity Mode
Setting B
Enable POP LIFO Mode
The POP feature will automatically cut off the power to the
newly inserted server (LIFO Mode), and then switch off servers
according to a preselected order (Priority Mode). T his ensures
other servers continue to work safely and are uninterrupted.
The POP feature will instantly cut off power to servers
according to the user’s predefined order.
Enable POP Prioity Mode
Setting C
Enable POP LIFO Mode
Enable POP Prioity Mode
The POP feature will automatically cut off the newly inserted
server, this ensures the whole PDU won’t shutdown and critical
servers are protected. And if there is not any newly inserted
server, then POP will only trip the alarm but won’t shut down
any outlet.
Scan here to view a video demonstrating ATEN’s Energy Intelligence PDUs & exclusive POP feature.
EC1000 / EC2004
EC1000
EC2004
Energy Box EC1000/EC2004
NRGence™ Energy Box is an intelligent 1U (0U vertical hook also available) power monitor unit which can monitor the current from
4 Energy PDUs and 4 temperature, humidity, or differential pressure sensors. It is a standalone Over IP monitor box that can be
controlled by Web UI or eco Sensors software. Conveniently deploying Energy Boxes in your rack, connected to Energy PDUs, allows
all power information from the PDUs to be collated and displayed on the Energy Box for easy viewing and monitoring.
• 4 Energy Sensor ports for Energy PDU power monitoring (0A
to 32A per port)
• 4 Environment Sensor ports for temperature, humidity and
differential pressure monitoring
• 1 Door Sensor port (EC2004 only)
• Space saving 0U/1U rack mount design
• Remote real-time current management and monitoring
- Current threshold level setting provision
- Name assignment to individual PDU
• Wide Management Option Range
- Remote management via IP network with Web Brower, eco
Sensors software or 3rd party SNMP manager
• Exceed threshold alert through
- Local: audible alarm and LED light blinking
- Remote: SMTP/SNMP trap/Syslog
Function
EC1000
Setup
EC2004
Inlet
Power Adapter DC 5V (1.8m)
Power Adapter DC 5V (1.8m)
Power Monitor
4xCurrent Energy Sensor Ports
2xCurrent + 2xCurrent&Voltage
Energy Sensor Ports
Sensor
4xEnvironment Sensor ports
4xEnvironment Sensor Ports +
1xDoor Sensor Port
LAN
1xRJ-45 Female with LED
1xRJ-45 Female with LED
100-240V; 50/60Hz; 0A to 32A(per port) 100-240V; 50/60Hz; 0A to 32A(per port)
LED Display Resolution 0.1A
LED Display Resolution 0.1A
Monitoring Range Accuracy: [email protected]~1A, +-1%@>1A
Accuracy: [email protected]~1A, +-1%@>1A
100VAC~250VAC, +-1%
100W~Maximum Capacity, +-2%
PE1216 / PE1324
PE2220 / PE2340
PE1216
PE2220
PE1324
PE2340
•
•
•
•
16 Outlets
0U
24 Outlets
0U
•
•
•
•
20 Outlets
0U
40 Outlets
0U
Energy PDU PE1216/PE1324/PE2220/PE2340
The Energy PDU contains 16/24/20/40 AC outlets and is available in various IEC or NEMA socket configurations. It features a spacesaving 0U design that allows it to be mounted vertically on the outside of the rack, resulting in a more efficient use of server room
space.
• Space saving 0U rack mount design
• IEC or NEMA outlet models
IEC System
Model
Rack
Space
Input
Voltage
Derated
Max AMP
AMP
PE1216G
0U
100-240V
16A
PE1324G
0U
100-240V
32A
PE2220G
0U
100-240V
PE2340G
0U
100-240V
Input Plug
# of
Banks
Outlets
Outlet
Control
16A
IEC C20
1x16A
16xIEC320 C13
None
Bank x 1 CE, C-Tick, TUV-CB, GOST, Others by Request
32A
IEC60309 32A
2x16A
24xIEC320 C13
None
Bank x 2 CE, C-Tick, GOST, Others by Request
16A
16A
IEC C20
1x16A
20xIEC320 C13
None
Bank x 1 CE, CE-LVD, TUV-CB, Others by Request
32A
32A
IEC60309 32A
2x16A
40xIEC320 C13
None
Bank x 2 CE, CE-LVD, TUV-CB, Others by Request
Input Plug
# of
Banks
Outlets
Outlet
Control
Meter
Certification
NEMA System
Model
Rack
Space
Input
Voltage
Derated
Max AMP
AMP
PE1216A
0U
100-120V
16A
20A
NEMA5-20P
1x20A
16xNEMA5-15R
None
Bank x 1 FCC, cTUVus, TUV-PSE, Others by Request
PE1216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
16xIEC320 C13
None
Bank x 1 FCC, cTUVus, TUV-PSE, Others by Request
Meter
Certification
PE1324B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
24xIEC320 C13
None
Bank x 2 FCC, cTUVus, TUV-PSE, Others by Request
PE2220A
0U
100-120V
16A
20A
NEMA5-20P
1x20A
20xNEMA5-15R
None
Bank x 1 FCC, TUV-CB, Others by Request
PE2220B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
20xIEC320 C13
None
Bank x 1 FCC, TUV-CB, Others by Request
PE2340B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
40xIEC320 C13
None
Bank x 2 FCC, TUV-CB, Others by Request
PE5108 / PE5208
PE6108 / PE6208
PE7108 / PE7208
PE8108 / PE8208
PE5108/PE5208
•
•
8 Outlets
1U
PE6108/PE6208
•
•
8 Outlets
1U
PE7108/PE7208
•
•
8 Outlets
1U
PE8108/PE8208
•
•
8 Outlets
1U
Power Distribution
Management
• Space saving rack mount design with rear mounting
• IEC or NEMA outlet models
• 3 x 7 segment front panel LED shows Current / IP Address
• Remote users can monitor outlet status via web pages on
their browsers
• Safe shutdown support
• Separate power for the unit's own power and its power
outlets – the user interface is still accessible even when an
overload condition trips the devices' circuit breakers
• Power status measurement at PDU level or outlet level (PE7/
PE8 Only)
• LED indicators for current and IP address at the PDU device
level
• Real-time current, voltage, and kWH displayed in a better
browser-based UI for monitoring at the PDU level
• Environment monitoring via external sensors for rack
temperature and humidity readings and alerts
• Current, voltage, power dissipation, energy consumption,
temperature and humidity threshold level setting
• Naming support for outlets
• User outlet access assignment on an outlet-by-outlet basis
• Event logging and syslog support
• Supports Management Information Base (MIB) files for SNMP
• Upgradeable firmware
• Multilanguage support
Remote Access
• Remote power control via TCP/IP and a built in 10/100
Ethernet port (PE6/PE8 Only)
• Network Protocols: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP,
DHCP, NTP, DNS, auto sense, Ping
• eco PDU Power Management software – eco Sensors
• Supports SNMP Manager V1, V2 & V3
Operation
• Remote power outlet control (On, Off, Power Cycle) by
individual outlets (PE6/PE8 Only)
• Supports multiple power control methods – Wake on LAN,
System After AC Back, Kill the Power (PE6/PE8 Only)
• Power- on sequencing – users can set the power- on
sequence and delay time for each outlet to allow equipment
to be powered on in the correct order (PE6/PE8 Only)
• Easy setup and operation via browser-based user interface
• Multibrowser support (IE, Firefox, Chrome, Safari)
• RTC support to keep the timer running during times of no
power
• Supports up to 8 user and 1 administrator accounts
• Proactive Overload Protection (POP) automatically powers
off outlets when current overloads to protect connected
devices (PE6/PE8 Only)
Security
• Two-level password security
• Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
• Remote authentication support: RADIUS
IEC System
Model
Rack
Space
Input Voltage
Derated
AMP
Max
AMP
Input Plug
# of
Banks
Outlets
Outlet
Control
PE5108G
1U
100-240V
10A
10A
IEC C14
1x10A
8xIEC320 C13
None
Bank x 1 CE, TUV-CB, CE-LVD, Others by Request
None
Bank x 1 CE, TUV-CB, CE-LVD, Others by Request
Meter
Certification
PE5208G
1U
100-240V
16A
16A
IEC C20
1x16A
7xIEC320
C13+1xIEC320 C19
PE6108G
1U
100-240V
10A
10A
IEC C14
1x10A
8xIEC320 C13
Yes
PE6208G
1U
100-240V
16A
16A
IEC C20
1x16A
7xIEC320
C13+1xIEC320 C19
Yes
PE7108G
1U
100-240V
10A
10A
IEC C14
1x10A
8xIEC320 C13
None
Outlet
CE, TUV-CB, CE-LVD, Others by Request
None
Outlet
CE, TUV-CB, CE-LVD, Others by Request
CE, TUV-CB, CE-LVD, GOST,
Others by Request
CE, TUV-CB, CE-LVD, GOST,
Others by Request
TUV-CB, CE-LVD, GOST,
Bank x 1 CE,
Others by Request
TUV-CB, CE-LVD, GOST,
Bank x 1 CE,
Others by Request
PE7208G
1U
100-240V
16A
16A
IEC C20
1x16A
7xIEC320
C13+1xIEC320 C19
PE8108G
1U
100-240V
10A
10A
IEC C14
1x10A
8xIEC320 C13
Yes
Outlet
PE8208G
1U
100-240V
16A
16A
IEC C20
1x16A
7xIEC320
C13+1xIEC320 C19
Yes
Outlet
NEMA System
Model
Rack
Space
Input Voltage
Derated
AMP
Max
AMP
Input Plug
# of
Banks
Outlets
Outlet
Control
PE5108A
1U
100-120V
12A
15A
NEMA5-15P
1x15A
8xNEMA5-15R
None
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
PE5108B
1U
100-240V
12A
15A
NEMA6-15P
1x15A
8xNEMA6-15R
None
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
PE5208A
1U
100-120V
16A
20A
NEMA5-20P
1x20A
8xNEMA5-20R
None
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
None
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
Meter
Certification
PE5208B
1U
100-240V
16A
20A
NEMA6-20P
1x20A
7xIEC320
C13+1xIEC320 C19
PE6108A
1U
100-120V
12A
15A
NEMA5-15P
1x15A
8xNEMA5-15R
Yes
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
PE6108B
1U
100-240V
12A
15A
NEMA6-15P
1x15A
8xNEMA6-15R
Yes
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
PE6208A
1U
100-120V
16A
20A
NEMA5-20P
1x20A
8xNEMA5-20R
Yes
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
Yes
Bank x 1 FCC, cTUVus, TUV-CB, Others by Request
PE6208B
1U
100-240V
16A
20A
NEMA6-20P
1x20A
7xIEC320
C13+1xIEC320 C19
PE7108A
1U
100-120V
12A
15A
NEMA5-15P
1x15A
8xNEMA5-15R
None
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE7108B
1U
100-240V
12A
15A
NEMA6-15P
1x15A
8xNEMA6-15R
None
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE7208A
1U
100-120V
16A
20A
NEMA5-20P
1x20A
8xNEMA5-20R
None
Outlet
FCC, cTUVus, TUV-CB, Others by Request
None
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE7208B
1U
100-240V
16A
20A
NEMA6-20P
1x20A
7xIEC320
C13+1xIEC320 C19
PE8108A
1U
100-120V
12A
15A
NEMA5-15P
1x15A
8xNEMA5-15R
Yes
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE8108B
1U
100-240V
12A
15A
NEMA6-15P
1x15A
8xNEMA6-15R
Yes
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE8208A
1U
100-120V
16A
20A
NEMA5-20P
1x20A
8xNEMA5-20R
Yes
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE8208B
1U
100-240V
16A
20A
NEMA6-20P
1x20A
7xIEC320
C13+1xIEC320 C19
Yes
Outlet
FCC, cTUVus, TUV-CB, Others by Request
PE5216 / PE5220s / PE5324 / PE5340s
PE6216 / PE6324
PE5324L / PE5340SL / PE6324L
PE5216/PE5220s
•
•
16/20 Outlets
0U
PE5324/PE5340s
•
•
24/40 Outlets
0U
PE6216/PE6324
•
•
16/24 Outlets
0U
PE5324L/PE5340SL/PE6324L
•
•
•
24/40 Outlets
0U
Low profile dimension
Power Distribution
Management
• Space saving rack mount design with rear mounting
• IEC or NEMA outlet models
• 3 x 7-segment front panel LED shows Current / IP Address
for PDU / Bank
• Remote users can monitor PDU/Bank status via web browser
• Safe shutdown support
• Separate power for the unit's own power and its power
outlets – the user interface is still accessible even when an
overload condition trips the devices' circuit breaker
• Power status measurement at the PDU/Bank level
• LED indicators for current and IP address at the PDU device
and/or Bank levels
• Real-time aggregate current, voltage and power, and power
dissipation displayed in a browser-based UI for monitoring
at the PDU level (PE5216/PE5220s/PE6216) and at the
bank level (PE5324/PE5324L/PE5340s/PE5340SL/PE6324/
PE6324L)
• Environment monitoring – supports external temperature /
humidity / differential pressure sensors for rack environment
monitoring
• Current and voltage threshold setting
• Naming support for outlets
*User outlet access assignment on an outlet-by-outlet basis
(PE6 Only)
• Event logging and syslog support
• Upgradeable firmware
• Multilanguage support: English, French, German, Italian,
Japanese, Simplified Chinese, Spanish, Russian,Traditional
Chinese
Remote Access
*Remote power control via TCP/IP and a built in 10/100
Ethernet port (PE6 Only)
• Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP,
DHCP, NTP, DNS, auto sense, Ping
• eco PDU Power Management software – eco Sensors
• Supports SNMP Manager V1, V2 & V3
Operation
*Remote power outlet control (On, Off, Power Cycle) by
individual outlets (PE6 Only)
*Supports multiple power control methods – Wake on LAN,
System After AC Back, Kill the Power (PE6 Only)
*Power- on sequencing – users can set the power- on
sequence and delay time for each outlet to allow equipment
to be powered on in the correct order (PE6 Only)
*Proactive Overload Protection (POP) automatically powers
off outlets when current overloads to protect connected
devices (PE6 Only)
• Easy setup and operation via browser-based user interface
• Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari,
Opera, Netscape)
• RTC support to keep the timer running during times of no
power.
• Up to 8 user accounts and 1 administrator account.
Security
• Two-level password security
• Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
• Remote authentication support: RADIUS
IEC System
Model
Rack
Space
Input Voltage
Derated
AMP
Max
AMP
# of
Banks
Outlets
IEC C20
1x16A
14xIEC320
C13+2xIEC320 C19
None
C-Tick, TUV-CB, GOST,
Bank x 1 CE,
Others by Request
Input Plug
Outlet
Control
Meter
Certification
PE5216G
0U
100-240V
16A
16A
PE5220sG
0U
100-240V
16A
16A
IEC C20
1x16A
20xIEC320 C13
None
Bank x 1 CE, TUV-CB, CE-LVD, Others by Request
PE5324G
0U
100-240V
32A
32A
2x16A
Bank x 2 CE, C-Tick, GOST, Others by Request
0U
100-240V
32A
32A
2x16A
21xIEC320
C13+3xIEC320 C19
21xIEC320
C13+3xIEC320 C19
None
PE5324LG*
None
Bank x 2 CE, CE-LVD, Others by Request
PE5340sG
0U
100-240V
32A
32A
2x16A
40xIEC320 C13
None
Bank x 2 CE, TUV-CB, CE-LVD, Others by Request
PE5340SLG*
0U
100-240V
32A
32A
IEC60309
32A
IEC60309
32A
IEC60309
32A
IEC60309
32A
2x16A
40xIEC320 C13
None
Bank x 2 CE, CE-LVD, Others by Request
14xIEC320
C13+2xIEC320 C19
21xIEC320
C13+3xIEC320 C19
21xIEC320
C13+3xIEC320 C19
Yes
C-Tick, TUV-CB, GOST,
Bank x 1 CE,
Others by Request
Yes
Bank x 2 CE, CE-LVD, Others by Request
Yes
Bank x 2 CE, CE-LVD, Others by Request
PE6216G
0U
100-240V
16A
16A
IEC C20
1x16A
PE6324G
0U
100-240V
32A
32A
2x16A
PE6324LG*
0U
100-240V
32A
32A
IEC60309
32A
IEC60309
32A
Derated
AMP
Max
AMP
2x16A
* Low profile dimension
NEMA System
Model
Rack
Space
Input Voltage
Input Plug
# of
Banks
Outlets
Outlet
Control
Meter
Certification
PE5216A
0U
100-240V
16A
20A
NEMA5-20P
1x20A
PE5216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
14xNEMA515R+2xNEMA5-20R
14xIEC320
C13+2xIEC320 C19
PE5220sA
0U
100-120V
16A
20A
NEMA5-20P
1x20A
20xNEMA5-15R
None
Bank x 1 FCC, TUV-CB, Others by Request
PE5220sB
0U
100-240V
16A
20A
NEMA6-20P
1x20A
20xIEC320 C13
None
Bank x 1 FCC, TUV-CB, Others by Request
None
Bank x 2 FCC, cTUVus, PSE, Others by Request
None
Bank x 1 FCC, cTUVus, PSE, Others by Request
None
Bank x 1 FCC, cTUVus, PSE, Others by Request
PE5324B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
PE5324LB*
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
21xIEC320
C13+3xIEC320 C19
21xIEC320
C13+3xIEC320 C19
None
Bank x 2 FCC, Others by Request
PE5340sB
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
40xIEC320 C13
None
Bank x 2 FCC, TUV-CB, Others by Request
PE5340SLB*
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
40xIEC320 C13
None
Bank x 2 FCC, Others by Request
14xNEMA515R+2xNEMA5-20R
14xIEC320
C13+2xIEC320 C19
21xIEC320
C13+3xIEC320 C19
21xIEC320
C13+3xIEC320 C19
Yes
Bank x 1 FCC, cTUVus, PSE, Others by Request
Yes
Bank x 1 FCC, cTUVus, PSE, Others by Request
Yes
Bank x 2 FCC, cTUVus, PSE, Others by Request
Yes
Bank x 2 FCC, Others by Request
PE6216A
0U
100-240V
16A
20A
NEMA5-20P
1x20A
PE6216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE6324B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
PE6324LB*
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
* Low profile dimension
PE7214 / PE7216 / PE7324 / PE7328
PE8216 / PE8324
PE9216 / PE9222 / PE9324 / PE9330
PE7214
PE7328
PE9216
PE7216
PE8216
PE9222
PE8324
PE9324
•
•
•
•
14 Outlets
0U
16 Outlets
0U
PE7324
•
•
24 Outlets
0U
•
•
•
•
•
•
28 Outlets
0U
16 Outlets
0U
24 Outlets
0U
•
•
•
•
•
•
16 Outlets
0U
PE9330
•
•
30 Outlets
0U
22 Outlets
0U
24 Outlets
0U
Power Distribution
Management
• Space saving rack mount design
• IEC or NEMA outlet models
• Remote users can monitor outlet status via web browser
• Safe shutdown support
• Separate power for the unit's own power and its power
outlets – the user interface is still accessible even when an
overload condition trips the devices' circuit breakers
• Power status measurement at PDU and outlet levels
• Current, voltage, power dissipation and energy consumption
displayed in a browser-based UI for monitoring at the outlet,
group, PDU levels
• Environment monitoring – supports external temperature /
temperature & humidity sensors for rack temperature and
humidity monitoring
• Current, voltage, power dissipation, energy consumption,
temperature and humidity threshold level setting
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis
• Event logging and syslog support
• Supports Management Information Base (MIB) files for SNMP
• Upgradeable firmware
• Multi-language support
• Proactive Overload Protection (POP) – automatically powers
off outlets when current overloads to protect operating
devices (PE8/PE9 only)
• Supports Door Sensor
Remote Access
• Remote power control via TCP/IP and a built in 10/100
Ethernet port (PE8/PE9 Only)
• Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP,
DHCP, NTP, DNS, auto sense, Ping
• eco PDU Power Management software – eco Sensors
• Supports SNMP Manager V1, V2 & V3
Operation
• Remote power outlet control (On, Off, Power Cycle) by
individual outlets and outlet groups (PE7 non-switching)
(PE8/PE9 Only)
• Supports multiple power control methods – Wake on LAN,
System After AC Back, Kill the Power (PE8/PE9 Only)
• Power- on sequencing – users can set the power- on
sequence and delay time for each outlet to allow equipment
to be powered on in the correct order (PE8/PE9 Only)
• Easy setup and operation via browser-based user interface
• Multibrowser support (IE, Firefox, Chrome, Safari)
• RTC support to keep the timer running during times of no
power
• Supports up to 8 user and 1 administrator accounts
• Critical load outlet – keeps power always on for critical load
devices ( PE9 only )
Security
• Two-level / Three-level password security
• Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
• Remote authentication support: RADIUS
Note : PE7 Outlet is always on.
IEC System
Model
Rack
Space
Input Voltage
Derated
AMP
Max
AMP
Input Plug
# of
Banks
PE7214G
0U
100-240V
16A
16A
IEC C20
1x16A
PE7216G
0U
100-240V
16A
16A
IEC C20
1x16A
PE7216G
0U
100-240V
16A
16A
IEC C20
1x16A
2x16A
PE7328G
0U
100-240V
32A
32A
IEC60309
32A
PE8216G
0U
100-240V
16A
16A
IEC C20
1x16A
PE8324G
0U
100-240V
32A
32A
IEC60309
32A
2x16A
PE9216G
0U
100-240V
16A
16A
IEC C20
1x16A
PE9222G
0U
100-240V
16A
16A
IEC C20
1x16A
IEC60309
32A
IEC60309
32A
2x16A
PE9324G
0U
100-240V
32A
32A
PE9330G
0U
100-240V
32A
32A
Input Voltage
Derated
AMP
Max
AMP
2x16A
Outlets
12xIEC320
C13+2xIEC320 C19
14xIEC320
C13+2xIEC320 C19
14xIEC320
C13+2xIEC320 C19
24xIEC320
C13+4xIEC320 C19
14xIEC320
C13+2xIEC320 C19
21xIEC320
C13+3xIEC320 C19
14xIEC320
C13+2xIEC320 C19
19xIEC320
C13+3xIEC320 C19
21xIEC320
C13+3xIEC320 C19
26xIEC320
C13+4xIEC320 C19
Outlet
Control
Meter
None
Outlet
CE, CE-LVD, Others by Request
None
Outlet
CE, CE-LVD, TUV-CB, Others by Request
None
Outlet
CE, CE-LVD, TUV-CB, Others by Request
None
Outlet
CE, CE-LVD, TUV-CB, Others by Request
Yes
Outlet
CE, CE-LVD, TUV-CB, Others by Request
Yes
Outlet
CE, CE-LVD, TUV-CB, Others by Request
Mix
Outlet
CE, CE-LVD, TUV-CB, Others by Request
Mix
Outlet
CE, CE-LVD, Others by Request
Mix
Outlet
CE, CE-LVD, TUV-CB, Others by Request
Mix
Outlet
CE, CE-LVD, TUV-CB, Others by Request
Outlet
Control
Meter
None
Outlet
FCC, Others by Request
None
Outlet
FCC, TUV-CB, Others by Request
None
Outlet
FCC, TUV-CB, Others by Request
None
Outlet
FCC, TUV-CB, Others by Request
Yes
Outlet
FCC, TUV-CB, Others by Request
Yes
Outlet
FCC, TUV-CB, Others by Request
Mix
Outlet
FCC, TUV-CB, Others by Request
Mix
Outlet
FCC, Others by Request
Mix
Outlet
FCC, TUV-CB, Others by Request
Mix
Outlet
FCC, TUV-CB, Others by Request
Certification
NEMA System
Model
Rack
Space
Input Plug
# of
Banks
PE7214B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE7216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE7324B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
PE7328B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
PE8216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE8216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE9216B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE9222B
0U
100-240V
16A
20A
NEMA6-20P
1x20A
PE9324B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
PE9330B
0U
100-240V
24A
30A
NEMAL6-30P
2x15A
Outlets
12xIEC320
C13+2xIEC320 C19
14xIEC320
C13+2xIEC320 C19
21xIEC320
C13+3xIEC320 C19
24xIEC320
C13+4xIEC320 C19
14xIEC320
C13+2xIEC320 C19
14xIEC320
C13+2xIEC320 C19
14xIEC320
C13+2xIEC320 C19
19xIEC320
C13+3xIEC320 C19
21xIEC320
C13+3xIEC320 C19
26xIEC320
C13+4xIEC320 C19
Certification
Energy & DCIM
Management Software
eco Sensors software has been developed to work with NRGence™ power distribution units (PDUs) to effectively increase the
efficiency of data center power usage. With the use of dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI) by
zone, eco Sensors software, in conjunction with sensor-enabled eco PDUs, gives you the means to assess, diagnose and estimate
how much energy you can save. Following the suggestions generated by the sensor-enabled system allows you to optimize energy
usage to save energy without harming your IT equipment’s reliability.
• Automatic discovery of all PE devices within the same intranet
• Remote real-time power measurement and monitoring
• PDU level current / voltage / power dissipation / power
consumption
• Outlet ON / OFF / Recycle status
• Remote real-time power outlet management*
• Power outlet ON / OFF / Cycle switching by outlet
• User-defined outlet level delays for sequential power up
• Current / Voltage / Power Dissipation / Power Consumption
threshold level setting
• User access assignment for every outlet
• Name assignment to individual outlets
• Remote real-time environment sensor monitoring
• Te m p e r a t u r e / Te m p e r a t u r e + H u m i d i t y r e a d i n g s /
Temperature + Differential Pressure
• Temperature and Humidity threshold level setting
• Plotting/Monitoring of all PE devices
• Add data center server racks
• Add PE devices for each server rack
• Manage device/device outlet status for each plot
• Offers essential data center indices including RCI (Rack
Cooling Index), RTI (Return Temperature Index), RHI (Rack
Humidity Index), RPI (Rack Pressure Index), RAI (Rack Airflow
Index)
• Power analysis report for optimizing data center energy
management – including power usage, power load, power
cost, CO2 cost, power capacity and trend
• Exceed threshold alert through SMTP and System log
• 1024 line event log
• System log provision
• Two-level password security
* Not all functions are supported by all NRGence™ PDUs. Please
visit www.aten.com for more details.
Setup
Hardware Requirements
System Parameters
Operating System
Windows XP / Windows Server 2003 and later
Max PDU number
2000
CPU
2.0 GHz Dual Core
Data Center Layout
45x30, 72x48, 90x60
Display
Larger than 1024x768
Max Rack Number
2000
Memory
2GB
Max Zone Number
100
Disk
500GB
Power Report Data
3 years
Network
10/100/1000 Mbp Ethernet
Real Time Dashboard Data
24 hours
Optional Accessories
Type
Environment Sensors
Door Sensors
Part No.
Description
EA1140
Temperature
EA1240
Temperature / Humidity
EA1340
Differential Pressure / Temperature
EA1440
Photo Door Sensor
EA1441
Inductive Proximity Door Sensor
EA1442
Reed Door Sensor
2X-EA07
Lok-U-Plug Cable Holder (10 pcs per pack)
2X-EA08
Lok-U-Plug Installation Tool (4 pcs per pack)
2X-015G
Double Mount Rail
2X-016G
Slide Rail Kit
2X-017G
Button Mount Kit
2X-018G
Side Panel Mount Kit
2X-019G
Side Panel Double Mount Kit
Cable Holders
Mounting Kits
Images