PLEASE READ AND FOLLOW ALL WARNINGS UT1550C

Add to My manuals
2 Pages

advertisement

PLEASE READ AND FOLLOW ALL WARNINGS UT1550C | Manualzz

PLEASE READ AND FOLLOW ALL WARNINGS

Read Operating Instructions

Always become familiar with all the instructions and warnings before operating any power tool.

Always Wear Approved

Eye Protection

Impact resistant eye protection should meet or exceed the standards as set forth in the United

States ANSI Z87.1, Occupational and Educational Eye and Face

Protection. Look for the marking

Z87.1 on your eye protection to insure that it is an approved style.

For further information, ANSI Z87.1,

Occupational and Educational Eye and Face Protection, is available from the American National

Standards Institute, Inc., 11 West

42nd Street, New York, NY 10036.

Hearing Protection is

Recommended

Hearing protection should be used when the noise level exposure equals or exceeds an 8 hour timeweighted average sound level of 85 dBA. Process noise, reflective surfaces, other tools being operated nearby, all add to the noise level present in your work area. If you are unable to determine your noise level exposure, we recommend the use of hearing protection.

Avoid Prolonged Exposure to

Vibration

Tools can vibrate during use.

Prolonged exposure to vibration

or very repetitive hand and arm movements, can cause injury.

Stop using any tool if discomfort, tingling feeling or pain occurs. You should consult your physician before resuming use of the tool.

90 PSIG Maximum

This tool is designed to operate at an air pressure of 90 pounds per square inch gauge pressure (90 PSIG) maximum, at the tool. Use of higher air pressure can, and may cause injury. Also, the use of higher air pressure places the internal components under loads and stresses they were not designed for, causing premature failure. The air supply should be clean and dry, preferably lubricated.

For best results, drain the moisture from

WARNING:

Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or reproductive harm. Some examples of these chemicals are:

• Lead from lead-based paints

• Crystalline silica from bricks, cement and other masonry products

• Arsenic and chromium from chemically treated lumber

Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals, work in a well-ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles.

Universal Tool

A Division of Florida Pneumatic Manufacturing Corporation

851 Jupiter Park Lane, Jupiter, Florida 33458

Toll Free 1-800-327-9403

UT1550C

1-1/2 STRAIGHT IMPACT WRENCH

Description

The Universal Tool professional tools feature alloy steel hammer cases that are machined from solid bar, not drawn or cast. The model number is laser etched on the hammer case for permanent identification. There is a high power to weight ratio, plus 100% parts interchangeability to the equivalent competitor’s tool. The features include steel hammer case and three piece housing construction for ease of maintenance. Also included are an adjustable power regulator, ergonomic handle and a sound reducing muffler.

instruct each operator in the safe use of the tool. Tools shall not be used without guards and safety devices as furnished by the manufacturer. Where an air tool is modified or altered, the modifier shall provide the safeguards to enable it to be safely used in the operations intended and to comply with any applicable provisions as contained in

ANSI B186.1.

Safety Instructions

The following instructions are furnished as general guidelines for use of your pneumatic tool. They cannot comprehensively cover all possible or conceivable uses of the subject tool. For additional information on the safe use of air tools, we advise you to obtain a copy of ANSI B186.1 Safety

Code for Portable Air Tools, available from the following source:

American National Standards

Institute, Inc.

11 West 42nd Street

New York, NY 10036.

The use of the word “shall” in the following instructions, indicates that adherence to the particular requirement is necessary to conform to ANSI B186.1.

Tool Application and Usage

Portable tools shall be used only for the purposes intended in their design and within the capacity for which they were intended and rated. It shall be the tool owner’s and/or employer’s responsibility to

Tool Installation

Pressure regulators shall be used to limit air pressure to the rated pressure where the supply pressure exceeds the tool’s rated pressure. Air hoses and lines shall be relieved of compressed air before being disconnected or disjointed, unless there is automatic valve closing protection at the joint being separated. Synthetic lubricants which can cause deterioration of elastomer seals shall not be used in air systems of air tools.

Tool Maintenance

It shall be the tool owner’s and/or employer’s responsibility to assure that tools are maintained in a safe operating condition. Tool maintenance and repair shall be performed by authorized, trained, competent personnel.

Tools shall be disconnected from their compressed air supply before repairs are attempted. Repairs shall be consistent with the manufacturer’s recommended procedures. Tool, hoses and fittings shall be replaced if unsuitable for safe operation. It shall be the tool owner’s and/or employer’s responsibility to keep required rating markings and warnings on the tool in legible condition.

Read these instructions carefully before attempting to install, operate or service this Florida Pneumatic product. Failure to comply with the instructions could result in personal injury and/or property damage!

Retain these instructions for future reference.

FPMC

UT1550C

1-1/2 STRAIGHT IMPACT WRENCH

Specifications

:

Shank ................................................................................................................................1-1/2”

Speed.............................................................................................................................3,750 RPM

Working Torque....................................................................................................725-2,500 ft. lbs.

Max. Torque ...............................................................................................................3,000 ft. lbs.

Weight..................................................................................................................................33 lbs.

Overall length...................................................................................................................14.50”

Average air consumption.............................................................................................17.5 CFM

Recommended hose size...................................................................................................3/4" I.D.

Air inlet.............................................................................................................................1/2" NPT

Maximum operating pressure ...........................................................................................90 psi

Parts Breakdown for UT1550C

USE ONLY IMPACT SOCKETS & ACCESSORIES

Sockets and accessories used shall be of the impact socket type. Always check sockets, retainers and drives regularly for wear or damage and replace whenever necessary

UT1550C

1-1/2 STRAIGHT IMPACT WRENCH

R44H-210A

2940-200

2934-301

N/A

2950-A40

2950-724

2950-A92

NL8

834-638

834-93

534-265

2950-302

2934-159

2934-A50

834-51

834-61

PART#

2950-726

2950-541

2950-A727

2945-638

NL10

845-364

834-48

2950-98

850-283

834-24

2950-12

2950-3

2950-42

2950-53

2950-11

845-565

130SR-188

2934-330S

4U-664

4U-663B

MR-207

R2-75

R2-71

2934-A329

85H-167

2934-658A

R00BR-210

TA-22

845-36

2950-A703

2950-704

R43F-104

2934-23A

2940P-311

2934-124

Replacement Parts for UT1550C

32

33

34

35

28

29.2

30.2

31

20

21

22

23

24

25

26.2

27

16

17

18

19

12

13

14

15

8

9

10

11

6

7

REF#

1.2

48

49

50

51

44

45

46

47

52

53

54

55

40

41

42

43

36

37

38

39

DESCRIPTION

1-1/2 SQ. DRIVE ANVIL

HAMMER CASE BUSHING

HAMMER CASE ASSEMBLY (INCL. #6)

HAMMER CASE CAP SCREW

3/8 NORD LOCK WASHER

BRACKET

ASSIST HANDLE

CYLINDER DOWEL PIN

HANDLE GASKET

BALL BEARING

REAR END PLATE

CYLINDER

VANE

ROTOR

FRONT END PLATE

AIRPORT GASKET

GASKET RETAINER

NAMEPLATE

NAMEPLATE RIVET

MOTOR HOUSING (INCL. #20, 21, 38)

HAMMER

INSIDE TRIGGER HANDLE (INCL. #29.2, 30.2, 31, 33, 34, 35, 36, 37, 42, 43, 47)

5/16 NORD LOCK WASHER

HANDLE CAP SCREW

INSIDE TRIGGER

TRIGGER PIN

THROTTLE VALVE PLUNGER

O RING

THROTTLE VALVE (INCL. #32)

THROTTLE VALVE SPRING

AIR STRAINER

STRAIGHT INLET

GREASE FITTING

REVERSE VALVE BUSHING

REVERSE LOCK SPRING

REVERSE LOCK PLUNGER

MOTOR CLAMP WASHER

OILER FELT

OILER ADJUSTING SCREW

REVERSE VALVE (INCL. #45)

O RING

REVERSE LEVER

REVERSE VALVE SEAL

BALL BEARING

HAMMER CASE GASKET

HAMMER FRAME (INCL. #51)

HAMMER PIN

BACKHEAD CAP SCREW

EXHAUST DEFLECTOR

EXHAUST SILENCER

EXHAUST BAFFLE

56 2934-223 EXHAUST GASKET

Limited Warranty

Universal Tool warrants its tools to be free from defects in material and workmanship for one year from the date of purchase. This warranty does not apply to tools which have been abused, misused, modified or repaired by someone other than Universal Tool or its authorized service centers. If a Universal Tool proves defective in material of workmanship within one year after purchase, return it to any authorized service center or to Universal

Tool, freight prepaid. Please enclose your name, address and adequate proof of purchase date with a brief description of the defect. Universal Tool will, at its option, repair or replace defective tools, free of charge. Repairs or replacements are warranted as described above for the remainder of the warranty period. Universal Tool's sole liability and your exclusive remedy under this warranty is limited to repair or replacement of the defective tool.

There are no other warranties expressed or implied and Universal Tool shall not be liable for incidental, consequential or special damages, or any other damages, costs or expense of repair or replacement as described above.

advertisement

Related manuals

Download PDF

advertisement