INSTALLATION DESCRIPTION

The Series 3000xTJ30 is a 1500 pound holding force top jamb-mounted electromagnetic lock designed to secure a single-inswinging door. The lock requires both installation procedures as described herein and in the separate wiring instructions included.

Typical installations of the lock on single-inswing doors:

LEFT HAND DOOR RIGHT HAND DOOR

HANDLING

Care must be taken that the lock face and armature face are kept free of dirt, rust, paint, or any other obstruction which may interfere with the lock and armature making good contact. These faces may be cleaned with a nonabrasive pad and wiped with an oil dampened cloth.

MECHANICAL INSTALLATION

Familiarize yourself with the door and frame conditions. The lock must mount rigidly to the face of the door frame header. The door mounted armature is supplied with an adjustable mounting bracket and hardware that allows it to pivot slightly to compensate for reasonable misalignment.

NOTE: If this lock is supplied with the DSM option be certain that disc magnets are present inside the armature housing.

ELECTRICAL INSTALLATION

After mechanical installation is complete the lock needs to be wired to a 12 or 24 VDC/VAC power source. Once low voltage power is supplied the unit is fully operational. All other wiring is for selected options. Refer to the separate wiring instructions included for further information.

3000xTJ30 MANUAL - FORM 3000TJ-003

Page 1

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

1.

Individual door and frame conditions may vary. Dimensions shown at right are for a typical hollow metal door and frame.

2.

The lock assembly should be mounted closest to the strike jamb of the frame for maximum performance. Verify that there is proper clearance for the lock assembly at the planned mounting location.

MOUNTING CONSIDERATIONS

1/8"

GAP

ARMATURE

LOCK ASSEMBLY

1/8"

GAP

SEX NUT

DOOR

2-1/2”

REF 1/4"

TYP.

1-1/4"

1/4"

REF.

2-3/4"

REF.

5-1/8"

REF.

ARMATURE BRACKET

MOUNTING SCREW

INSTALL THE LOCK ASSEMBLY

1.

Drill out the four dimpled mounting hole locations inside the back of the lock housing using a 3/16” drill. Position the lock assembly on the face of the frame header, on the pull side of the door, as shown. Locate and mark the centers of the four mounting holes.

2.

Drill the marked holes in the face of the frame header:

Four (4) 1/8” dia. mounting holes.

3.

Attach the lock assembly to the frame header using four (4)

#10 x 1” pan head Tek screws. Firmly tighten the screws using a #2 phillips screwdriver.

MOUNTING

HOLES

FLUSH

WITH FRAME

RABBET

1/8” ABOVE

HEADER

RABBET

1/8” ABOVE

HEADER

RABBET

MOUNTING

HOLES

FLUSH

WITH FRAME

RABBET

LEFT HAND DOOR

3000xTJ30 MANUAL - FORM 3000TJ-003

HINGE SIDE

OF DOOR

Page 2

HINGE SIDE

OF DOOR

RIGHT HAND DOOR

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

ASSEMBLE THE ARMATURE MOUNTING BRACKET

Locate the two armature mounting bracket assembly screws and lock washers from the hardware kit and assemble the bracket as shown.

Firmly tighten the mounting screws with a

5/32” hex wrench. They may be loosened later for adjustment, as necessary.

BRACKET ASSEMBLY SCREW

LOCK WASHER

UPPER ARMATURE

BRACKET

LOWER ARMATURE BRACKET

ATTACH THE ARMATURE TO THE ARMATURE MOUNTING BRACKET

Attach the Armature Housing to the top Armature Mounting Bracket using four (4) 8-32x3/8” Armature Housing

Screws.

Attach the armature to the armature mounting bracket as shown for LH door (Use alternate holes for RH door).

Firmly tighten the Armature Mounting Screw using a 3/16” hex wrench.

Failure to properly secure the armature to the bracket could result in serious injury or possible security breach.

ARMATURE HOUSING

ARMATURE

MOUNTING

SCREW

ARMATURE

SPACER

3000xTJ30 MANUAL - FORM 3000TJ-003

ARMATURE

FLAT

STEEL WASHER

ARMATURE HOUSING SCREW

ARMATURE MOUNTING BRACKET

Page 3

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

INSTALL THE ARMATURE MOUNTING BRACKET

1.

Use the fi gures below to identify and mark the locations of the armature mounting bracket screw holes on the door.

Refer to door and frame prep drawing #301093 for further information.

LEFT HAND DOOR RIGHT HAND DOOR

1-3/8”

FROM

HEADER

RABBET

HINGE SIDE

OF DOOR

1-3/8”

FROM

HEADER

RABBET

HINGE SIDE

OF DOOR

1-5/8”

FROM

FRAME

RABBET

7-3/4”

Drill an 11/32” diameter hole through door. From sex nut side only enlarge the 11/32” hole to 21/32” diameter.

Drill an 11/32” diameter hole through door. From sex nut side only drill 1/2” diameter hole to 1” depth.

7-3/4”

1-5/8”

FROM

FRAME

RABBET

2.

From the illustrations below select the one that resembles your door type and follow the instructions for drilling the two (2) armature mounting bracket screw holes.

DOOR

SPACER

SEX

NUT

GLASS & ALUMINUM

OR HOLLOW METAL DOOR

LOWER ARMATURE

MOUNTING BRACKET

ARMATURE BRACKET

MOUNTING SCREW

21/32”

SEX

NUT

1”

1/2”

SOLID CORE DOOR

LOWER ARMATURE

MOUNTING BRACKET

ARMATURE BRACKET

MOUNTING SCREW

5/16”-18

THREAD

REINFORCED DOOR

LOWER ARMATURE

MOUNTING BRACKET

ARMATURE BRACKET

MOUNTING SCREW

1/4” MIN

Drill an 11/64” diameter hole and tap for 5/16”-18 thread.

3.

Mount the armature and mounting bracket assembly to the door using the appropriate hardware for you door type.

Firmly tighten the mounting screws with a 3/16” hex wrench.

3000xTJ30 MANUAL - FORM 3000TJ-003

Page 4

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

ARMATURE ADJUSTMENT

1.

Using a 5/32” hex wrench, temporarily loosen the armature bracket assembly screws roughly 1-1/2 turns to allow the upper armature bracket to move in and out freely (Ref. Figure “A”).

2.

Close and latch the door. The mating surfaces of the lock and armature should fully contact each other. If necessary, slide the armature in or out to ensure full contact is made with the lock while still allowing the door to properly close and latch.

3.

When the desired adjustment is achieved, slowly open the door taking care to maintain the position of the armature. Firmly tighten the armature bracket assembly screws, making sure that the locking ribs on the upper and lower bracket halves properly mesh (Ref. Figure “A”)

NOTE:

Make sure the door hits the frame just before the armature hits the maglock, to prevent loosening over time (armature not slamming against the lock).

Figure “A”

ASSEMBLY

SCREW

LOWER

ARMATURE

BRACKET

ARMATURE

LOCK ASSEMBLY

UPPER ARMATURE BRACKET

ARMATURE BRACKET

ADJUSTMENT RANGE

1”

3000xTJ30 MANUAL - FORM 3000TJ-003

DOOR

Page 5

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

EXPLODED PARTS VIEW LEGEND

ITEM DESCRIPTION

1 Housing Assembly

2 Armature

3 Upper Armature Bracket

4 Lower Armature Bracket

5 Access Cover

6 8-32x3/8” Machine Screw

7 End Cover

8 1/4-20x1/2” Button Head Screw

9 Lock Washer

10 #10x1” Self-Tapping Screw

10 10-24x1/2” Machine Screw

*

Part of Hardware Kit (301315)

Refer to Page 7 for parts locations.

PART #

300007

300013

301254

301260

300009

300608

300010

*

*

*

*

ITEM DESCRIPTION

11 5/16-18x3/4” Arm. Screw, Turned

12 0.235”L Armature Spacer

14 Flat Steel Washer

15 Sex Nut

16 Door Spacer Tube

17 5/16-18x1-3/4” Bolt

18 Armature Housing

PART #

*

*

*

*

*

*

301244

19 8-32x3/8” Machine Screw *

20 Disc Magnet (DSM & HSM only) 301289

3000xTJ30 MANUAL - FORM 3000TJ-003

Page 6

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

EXPLODED PARTS VIEW

Note: Refer to Page 6 for parts legend.

3000xTJ30 MANUAL - FORM 3000TJ-003

Page 7

02/07

705 Emmett Street Bristol, CT 06010

1-877-DynaLock www.dynalock.com

MODEL 3000xTJ30

ELECTROMAGNETIC LOCK

INSTALLATION INSTRUCTIONS

PLEASE DELIVER THIS MANUAL

TO THE END-USER UPON COMPLETION

OF THE INSTALLATION

FOR PRODUCT SUPPORT AND PARTS

ORDERING INFORMATION CONTACT:

DynaLock Corp.

705 Emmett Street

Bristol, CT 06010

Bus: (877) 396-2562 Toll-Free

(860) 582-4761

Fax: (860) 585-0338

DYNALOCK ON THE INTERNET:

E-mail: [email protected]

Website: www.dynalock.com

C

R

UL

LISTED

US

NYC Mea #23-92-E

GWXT Auxiliary Lock

CSFM

3000xTJ30 MANUAL - FORM 3000TJ-003

Page 8

02/07

advertisement

Related manuals

Download PDF

advertisement