- No category
advertisement
Datasheet LFP12100 12V LiFePO4 battery
This specification applies to the 12V LiFePO4 battery. Describes the type and size, performance, technical characteristics, warning and caution of the rechargeable cell.
Battery Design specification
Items
Battery type:
Nominal voltage:
Nominal capacity:
Internal impedance:
Specifications
LiFePO4
12.8V
100Ah
< 60mΩ
Nominal charge voltage:
Discharge cut off voltage:
Max. charge current:
14.6+0.05V
9.2+0.05V
80A
Max. continue discharge current: 100A
Max. discharge pulse current: 300A (2s)
Charge method:
Cycle life:
CC/CV (constant current/constant voltage)
Weight:
Size (LxWxH):
2000
After 2000 cycles, capacity more than 80% nominal capacity
Approx. 15.5kg
Operating temperature:
Storage temperature:
327x172x216mm
Charge: 0°C - -45°C
Discharge: -10°C - -60°C
5°C – 35°C
Relative humidity: 65+20%
Battery terminals
Connector
P+
P-
Min.
9.2V
0V
Voltage
Typical
12.8V
0V
Max.
14.6V
0V
Current
100A
AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk
Electrical structure
PCM parameters
Function
Over discharge
Item
Over charge Over-charge protection for each cell
Over-charge recover protection recover for each cell
Over-discharge protection for each cell
Over-discharge recover protection for each cell
Over-current protection
Temperature protection
Discharge overcurrent protection
Recover of over current protection
Over temperature protection
Over temperature protection recover
Min.
3.775
3.55
1.92
2.20
550
Cut off the load or charging recovery
60 65 70
50
Typical Max. Unit
3.800 3.825 V
3.60
2.00
2.30
650
55
3.65
2.08
2.40
750
60
V
V
V
A
°C
°C
AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk
Dimensions
Electrical
Standard Charge
Charging the cell initially with constant current at 0.2C and then with constant voltage at 14.6V (accuracy
+0.05V) till charging current declines to 0.02C at 25°C.
Standard discharge
Discharging the cell with constant current at 0.2C till cut-off voltage at 9.2V. Temperature: 25°C.
Initial internal impedance
This means AC impedance of the pack measured at 1kHz after 50% charge. Initial Internal
Impedance≦60mΩ.
Initial capacity
The capacity means the discharge capacity of the battery, which is measured with discharge current of 0.2C with 9.2V cut-off voltage after the standard charge. Initial Capacity≧95% Nominal Capacity. Temperature:
25°C.
Battery capacity as shipment
Capacity of battery pack shipment is more than 50%.
AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk
Cycle life
Test condition: Temperature: 25 ~ 30°C Charge, 0.2C CC to 14.6V, and CV to 200mA cut off Discharge, 0.2C
DC discharge to 9.2V, 80% or more of 1st cycle capacity at 0.2C discharge of operation, cycles quantity must not be less than 2000cycles.
Remark: Rest 10 min after charge - Rest 10 min after discharge
Charger choice
1. Standard charger: 14.6V/4A.
2. It's very important to choose the matching charger, or else will influence the performance and life of battery.
3. Charger requirements: a. Charging mode: CC/CV b. CC:charging current≤ 10A c. CV:constant voltage 14.6V d. Charging cut off condition:≤ 200mA
Instructions and cautions
1. Please read the battery specification before using the battery.
2. Use the battery indoor under normal condition and in accordance with specifications.
3. Must not be used or storaged in the environment of corrosively, explosiveness, high temperature
(like in hot environments or direct sun exposure)
4. Use a compatible charger.
5. Do not short circuit terminals. Do not demolish or disassembly the battery.
6. Guarantee is two years as of invoice date. Life time: 2000 cycles or 2 years. Any damage by incorrect use will void the guarantee. Free service will not be provided by the manufacturer.
7. The battery must be used in the assigned application.
8. Disposal of the batteries must be at approved recycling centers and in accordance with national legislation.
AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk