LiFePO4 12V 100A battery

Add to my manuals
4 Pages

advertisement

LiFePO4 12V 100A battery | Manualzz

Datasheet LFP12100 12V LiFePO4 battery

This specification applies to the 12V LiFePO4 battery. Describes the type and size, performance, technical characteristics, warning and caution of the rechargeable cell.

Battery Design specification

Items

Battery type:

Nominal voltage:

Nominal capacity:

Internal impedance:

Specifications

LiFePO4

12.8V

100Ah

< 60mΩ

Nominal charge voltage:

Discharge cut off voltage:

Max. charge current:

14.6+0.05V

9.2+0.05V

80A

Max. continue discharge current: 100A

Max. discharge pulse current: 300A (2s)

Charge method:

Cycle life:

CC/CV (constant current/constant voltage)

Weight:

Size (LxWxH):

2000

After 2000 cycles, capacity more than 80% nominal capacity

Approx. 15.5kg

Operating temperature:

Storage temperature:

327x172x216mm

Charge: 0°C - -45°C

Discharge: -10°C - -60°C

5°C – 35°C

Relative humidity: 65+20%

Battery terminals

Connector

P+

P-

Min.

9.2V

0V

Voltage

Typical

12.8V

0V

Max.

14.6V

0V

Current

100A

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk

Electrical structure

PCM parameters

Function

Over discharge

Item

Over charge Over-charge protection for each cell

Over-charge recover protection recover for each cell

Over-discharge protection for each cell

Over-discharge recover protection for each cell

Over-current protection

Temperature protection

Discharge overcurrent protection

Recover of over current protection

Over temperature protection

Over temperature protection recover

Min.

3.775

3.55

1.92

2.20

550

Cut off the load or charging recovery

60 65 70

50

Typical Max. Unit

3.800 3.825 V

3.60

2.00

2.30

650

55

3.65

2.08

2.40

750

60

V

V

V

A

°C

°C

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk

Dimensions

Electrical

Standard Charge

Charging the cell initially with constant current at 0.2C and then with constant voltage at 14.6V (accuracy

+0.05V) till charging current declines to 0.02C at 25°C.

Standard discharge

Discharging the cell with constant current at 0.2C till cut-off voltage at 9.2V. Temperature: 25°C.

Initial internal impedance

This means AC impedance of the pack measured at 1kHz after 50% charge. Initial Internal

Impedance≦60mΩ.

Initial capacity

The capacity means the discharge capacity of the battery, which is measured with discharge current of 0.2C with 9.2V cut-off voltage after the standard charge. Initial Capacity≧95% Nominal Capacity. Temperature:

25°C.

Battery capacity as shipment

Capacity of battery pack shipment is more than 50%.

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk

Cycle life

Test condition: Temperature: 25 ~ 30°C Charge, 0.2C CC to 14.6V, and CV to 200mA cut off Discharge, 0.2C

DC discharge to 9.2V, 80% or more of 1st cycle capacity at 0.2C discharge of operation, cycles quantity must not be less than 2000cycles.

Remark: Rest 10 min after charge - Rest 10 min after discharge

Charger choice

1. Standard charger: 14.6V/4A.

2. It's very important to choose the matching charger, or else will influence the performance and life of battery.

3. Charger requirements: a. Charging mode: CC/CV b. CC:charging current≤ 10A c. CV:constant voltage 14.6V d. Charging cut off condition:≤ 200mA

Instructions and cautions

1. Please read the battery specification before using the battery.

2. Use the battery indoor under normal condition and in accordance with specifications.

3. Must not be used or storaged in the environment of corrosively, explosiveness, high temperature

(like in hot environments or direct sun exposure)

4. Use a compatible charger.

5. Do not short circuit terminals. Do not demolish or disassembly the battery.

6. Guarantee is two years as of invoice date. Life time: 2000 cycles or 2 years. Any damage by incorrect use will void the guarantee. Free service will not be provided by the manufacturer.

7. The battery must be used in the assigned application.

8. Disposal of the batteries must be at approved recycling centers and in accordance with national legislation.

AWILCO-MULTIPLEX ApS | Yderholmvej 64 | DK-4623 Ll. Skensved | Phone: +45 5656 5400 | Fax: +45 5656 5405 [email protected] | www.awilco-multiplex.dk

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project