Spirit Gas TG8S Single Stage PSC 80% Specs

Add to My manuals
4 Pages

advertisement

Spirit Gas TG8S Single Stage PSC 80% Specs | Manualzz
T C NC
G I E
GAS-FIRED RESIDENTIAL
SINGLE STAGE MULTI-POSITION
GAS FURNACES
MODELS: TG8S
NATURAL GAS
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
FEATURES
60 - 130 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
Standard 5-year limited Parts warranty.
• Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
• Low unit amp requirement for easy replacement application.
• Single wire twinning or staging feature available.
• All models are convertable to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with increased
dependability and reliability.
• 100% shut off main gas valve for extra safety.
• 4 speed, direct drive PSC motor.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Timed on, adjustable off blower capability for maximum comfort.
• Blower door safety switch.
• Airflow leakage less than 1% of total airflow at ductblaster
conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Venting applications - may be installed as a common vent
with other gas-fired appliances or use a masonry chimney.
• 1/4 turn knobs provided for easy door removal.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replacement or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
LEFT SIDE
FRONT
Vent Connection
Outlet
RIGHT SIDE
Electrical
Entry
Vent
Connection
Outlet
Electrical
Entry
Gas Pipe
Entry
33”
Gas Pipe
Entry
23”
Thermostat
Wiring
Thermostat
Wiring
14”
A
28.5”
29.5”
4” Diameter
Vent Connection
Outlet
24.38”
.5”
1”
1.5”
.5”
.5”
B
B
C
.5”
20”
24.25”
SUPPLY END
RETURN END
Cabinet and Duct Dimensions
Models
Nominal
CFM
TG(8,L)S060A12MP11
TG(8,L)S080C16MP11
TG(8,L)S100C20MP11
TG(8,L)S120C20MP11
Cabinet
Size
(m3/min)
1200
1600
2000
2000
A
C
C
C
Approximate
Operating Weights
Cabinet Dimensions (Inches)
A
B
C
Lbs
14 1/2
21
21
21
13 3/8
19 7/8
19 7/8
19 7/8
10.3
13.6
13.6
15.8
94
114
122
129
Ratings & Physical / Electrical Data
Models
TG(8,L)S060A12MP11
TG(8,L)S080C16MP11
TG(8,L)S100C20MP11
TG(8,L)S120C20MP11
Input Output
MBH
60
80
100
120
MBH
48
64
80
96
AFUE
80.0
80.0
80.0
80.0
Air Temp. Max. Outlet
Rise
Air Temp
°F
°F
30-60
160
25-55
155
25-55
155
30-60
160
Max
Blower
Over-Current
Size
Protect
Amps
4.8
11 x 8
10
7.5 11 x 10
15
14.5 11 x 11
20
14.5 11 x 11
20
Blower
HP
1/3
1/2
1
1
Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
2
Min. wire Size
Total Unit
(awg) @ 75 ft
Amps
one way
7.0
14
10.0
14
17.0
12
17.0
12
HORIZONTAL SIDEWALL VENTING
Recommended Filter Sizes
For applications where vertical venting is not possible, the only
approved method of horizontal venting is the use of an auxiliary
power vent. Auxilary power venters must be approved by CSA,
UL, or other recognized safety agencies. Follow all application
and installation details provided by the manufacturer of the
power vent.
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” tables shown represents blower performance WITHOUT filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.
NOTICE
CFM
Cabinet
Size
Side
(in)
Bottom
(in)
800
A
16 x 25
14 x 25
1000
1200
1200
1600
1600
2000
2200
2000
A
A
B
B
C
C
C
D
16 x 25
16 x 25
16 x 25
16 x 25
16 x 25
(2) 16 x 25
(2) 16 x 25
(2) 16 x 25
14 x 25
14 x 25
16 x 25
16 x 25
20 x 25
20 x 25
20 x 25
22 x 25
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer’s recommendation and a transition is used to allow use on a
20x25 filter.
Unit Clearances to Combustibles (All dimensions in inches,
and all surfaces identified with the unit in an upflow
configuration)
Top
Front
Rear
Left
Side
Right
Side
Flue
Floor/
Bottom
Closet
Alcove
Attic
Line
Contact
Upflow
Upflow B-Vent
1
1
6
3
0
0
0
0
3
0
6
1
Combustible
Combustible
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Downflow
1
6
0
0
3
6
11
Yes
Yes
Yes
No
Downflow B-Vent
1
3
0
0
0
1
11
Yes
Yes
Yes
No
Horizontal
1
6
0
0
3
6
Combustible
No
Yes
Yes
Yes2
Horizontal B-Vent
1
3
0
0
0
1
Combustible
No
Yes
Yes
Yes2
Application
1. Special floor base or air conditioning coil required for use on combustible
floor.
2. Line contact only permitted between lines formed by the intersection of
the rear panel and side panel (top in horizontal position) of the furnace
jacket and building joists, studs or framing.
ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas units for propane (LP) operation.
1NP0347 - All Models
Side Return Filter Racks 1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
1BR0514 - For 14-1/2” cabinets,
1BR0517 - For 17-1/2” cabinets,
1BR0521 - For 21” cabinets
1BR0524 - For 24-1/2” cabinets
3
Blower Performance CFM - Any Position (without filter) - Bottom Return
Bottom Airflow Data (SCFM)
Models
TG(8,L)S060A12MP11
TG(8,L)S080C16MP11
TG(8,L)S100C20MP11
TG(8,L)S120C20MP11
Ext. Static Pressure (in. H2O)
Speed
High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1358
1097
935
800
1881
1553
1312
1169
2893
2272
1765
1425
2701
2125
1664
1358
1341
1083
928
779
1822
1535
1286
1166
2774
2243
1752
1380
2620
2083
1664
1339
1319
1075
920
763
1783
1492
1288
1128
2687
2204
1737
1409
2533
2046
1647
1330
1303
1064
899
736
1696
1456
1260
1098
2589
2169
1718
1378
2429
1994
1619
1318
1275
1042
872
711
1602
1408
1205
1069
2478
2086
1674
1307
2338
1955
1580
1286
1238
1024
840
687
1539
1343
1143
1032
2376
2018
1619
1274
2227
1901
1555
1235
1190
997
809
657
1465
1279
1091
987
2255
1940
1561
1226
2112
1857
1468
1185
1130
962
771
622
1394
1226
1029
909
2120
1842
1493
1180
1993
1737
1392
1141
1062
906
731
584
1267
1113
966
835
1978
1743
1437
1113
1861
1621
1332
1060
943
821
659
529
1130
1014
841
747
1824
1602
1312
1025
1706
1497
1226
938
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Motor voltage at 115 V
Left Side Airflow Data (SCFM)
Models
TG(8,L)S060A12MP11
TG(8,L)S080C16MP11
TG(8,L)S100C20MP11
TG(8,L)S120C20MP11
Ext. Static Pressure (in. H2O)
Speed
High
Medium High
Medium Low
Low
High
Medium High
Medium
Low
High
Medium High
Medium Low
Low
High
Medium High
Medium Low
Low
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1406
1129
970
834
1825
1516
1294
1126
2964
2192
1699
1361
2828
2085
1620
1322
1401
1126
947
809
1781
1493
1297
1115
2886
2178
1695
1356
2768
2073
1631
1311
1394
1107
933
797
1746
1482
1271
1095
2794
2150
1706
1337
2699
2042
1636
1302
1379
1094
916
768
1695
1464
1238
1049
2707
2109
1632
1304
2612
2029
1593
1271
1338
1076
890
740
1641
1442
1187
1027
2623
2098
1612
1267
2524
1967
1567
1241
1304
1047
863
710
1587
1411
1120
996
2522
2007
1568
1243
2423
1896
1557
1201
1261
1010
827
677
1521
1343
1083
957
2415
1956
1519
1191
2308
1893
1520
1162
1202
966
789
634
1429
1275
1028
929
2281
1888
1460
1149
2219
1816
1476
1101
1135
921
741
586
1330
1192
979
840
2149
1795
1392
1077
2118
1717
1407
1042
1040
843
668
534
1184
1035
851
742
2012
1671
1293
994
1982
1635
1263
979
Airflow expressed in standard cubic feet per minute (CFM).
1. Return air is through side opposite motor (left side).
2. Motor voltage at 115 V.
3. Airflow through across motor side (right side) may be slightly less than the data shown above.
4

advertisement

Related manuals

Download PDF

advertisement