AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS NEW 2012 2012 ‘ECO IDEAS’ FOR LIFESTYLES: WE WILL PROMOTE LIFESTYLES WITH VIRTUALLY ZERO CO2 EMISSIONS THROUGHOUT THE WORLD. SPECIFICALLY: · 30% of total sales will be achieved through “eco labeled” products. This includes both external labels such as EU eco flower, Blue Angel or Nordic Swan, and our internal ‘eco ideas’ label, which is given to products which achieve industry-leading environmental performance. 1) · 3,500,000t of contribution in reducing CO2 emissions with energy solution products (such as Solar Panels, Fuel Cells, Heat Pumps, Energy Recovering Ventilation, LED and Energy Saving Lamps). 2) · Educate 100,000 children on eco related topics through the ‘kids school – eco learning’ programme. ‘ECO IDEAS’ FOR BUSINESS-STYLES: WE WILL CREATE AND PURSUE BUSINESS-STYLES THAT MAKE THE BEST USE OF RESOURCES AND ENERGY: · 99% of waste materials generated in European production will be recycled 3), meaning less than 1% will be allowed to go to landfill. · 1,000t of reduction in CO2 emissions from Panasonic’s offices across Europe. 4) · 7,000t of contribution in reducing CO2 emissions from production activities. 5) 1) Products awarded the ‘eco ideas’ label include those whose environmental performance is greater than the industry’s No.2 model by 10% or more at the time of release, and those which achieve the highest rank in the market by external environmental labels in accordance to environmental performance. 2) An amount of CO2 reduction compared to the estimated figure assuming no improvement. Measures were taken after March 31, 2006. 3) Includes all Panasonic Group’s European factories with the exception of IPS-Alpha and Panasonic 4) Based on offices with 100 employees or more; based on FY 2009. 5) An amount of CO2 reduction compared to the estimated figure assuming no improvement. Measures were taken after March 31, 2006. 2 PANASONIC GLOBAL VISION The Panasonic Group strives to be a green innovation company with a global perspective. Its aim is to be the leading green company in the electronics sector by 2018 - the year that Panasonic celebrates its centenary. HEATING & COOLING Panasonic Home Appliances is the European leader in heating and cooling solutions for the home. When it comes to market share, Panasonic is the No. 1 company for home solutions in Europe, the No. 1 company for domestic cooling & heating solutions in Spain, and the No. 1 company for heating systems in the Nordic countries. Panasonic invests significantly in Research & Development, with a strong network of design, manufacturing and training centres throughout Europe. As part of Panasonic’s continued programme of growth, a new R&D facility is open in Langen, Germany. The centre is focused on developing products to meet the needs of European customers, as well as European legislation. ECO IDEAS FOR LIFESTYLES Panasonic is making the environment central to all of its business activities. It will become the No 1 green innovation company in the electronics sector through its eco ideas initiative: eco ideas for lifestyles to change people’s lives and eco ideas for business to bring forth green innovation in Panasonic’s own global business operations. Panasonic always strives to offer better living, with a sense of joy, security and comfort, as well as with virtually zero CO2 emissions in the entire house or building. ECO IDEAS FOR BUSINESS Panasonic will create and pursue a business-style which makes the best use of resources and energy. As well as making eco-conscious products and delivering them to customers, Panasonic aims to reduce waste of energy and resources during the manufacturing process. As well as tackling its own business, Panasonic will take a leading role for sharing and working on environmental challenges in entire societies. SUMMARY PANASONIC – LEADING THE WAY IN HEATING & COOLING .................................................................. 4 IDEAS FOR A CLEANER FUTURE ........................................................................................................ 6 REALISING ECO-CONSCIOUS SOLUTIONS IN ENTIRE TOWNS............................................................... 8 PANASONIC PROFESSIONAL ........................................................................................................... 10 AQUAREA’S NEW AIR-TO-WATER HEAT PUMP .................................................................................. 12 "GREEN" HIGH-EFFICIENCY ............................................................................................................ 14 NEW LINE-UP ................................................................................................................................ 16 NEW AQUAREA 3 AND 5 KW BI-BLOC AND 6 AND 9 KW MONO-BLOC AIR TO WATER HEAT .................. 18 HEAT PUMP + PHOTOVOLTAIC ......................................................................................................... 20 INVERTER+ COMPRESSOR FOR EVEN GREATER EFFICIENCY ............................................................. 22 WHAT MAKES THE AIR-TO-WATER HEAT PUMP WORK ...................................................................... 24 CONTROL YOUR HEAT PUMP WITH YOUR SMART DEVICE -SMARTPHONE & INTERNET- ...................... 26 CONNECTIVITY ............................................................................................................................... 28 HP BI-BLOC AND MONO-BLOC APPLICATION EXAMPLES .................................................................. 30 AQUAREA LINE-UP ......................................................................................................................... 32 BI-BLOC // HIGH CONNECTIVITY // 3 AND 5 KW AQUAREA // HEATING ONLY - SDF // HEATING AND COOLING - SDC......................................................................................................... 34 AQUAREA MDF & MDC // MONO-BLOC // HIGH CONNECTIVITY // 6 AND 9 KW AQUAREA // HEATING AND COOLING // SINGLE-PHASE ....................................................................................... 36 AQUAREA SDF // BI-BLOC // HIGH CONNECTIVITY // HEATING ONLY SINGLE-PHASE // THREE-PHASE....... 38 AQUAREA SDC // BI-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE ............................................................................................................................... 40 AQUAREA MDF // MONO-BLOC // HIGH CONNECTIVITY // HEATING ONLY SINGLE-PHASE // THREE-PHASE ............................................................................................................................... 42 AQUAREA MDC // MONO-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE..................................................................................................... 44 AQUAREA SXF // BI-BLOC // T-CAP // HEATING ONLY SINGLE-PHASE // THREE-PHASE ....................... 46 AQUAREA SXC // BI-BLOC // T-CAP // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE.......... 48 AQUAREA MXF // MONO-BLOC // T-CAP // HEATING ONLY SINGLE-PHASE // THREE-PHASE ................ 50 AQUAREA MXC // MONO-BLOC // T-CAP // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE... 52 AQUAREA SHF // BI-BLOC // HT // HEATING ONLY SINGLE-PHASE // THREE-PHASE ............................ 54 AQUAREA MHF // MONO-BLOC // HT // HEATING ONLY SINGLE-PHASE // THREE-PHASE..................... 56 AQUAREA PRO // THE NEW PANASONIC SOLUTION FOR CHILLED AND HOT WATER PRODUCTION! ...... 58 AQUAREA PRO // NEW ECOI 2-WAY 6 SERIES WITH WATER HEAT EXCHANGER .................................. 60 AQUAREA PRO // NEW GAS VRF ECO G WITH WATER HEAT EXCHANGER ............................................ 62 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE ............... 64 ACCESSORIES ................................................................................................................................ 66 3 PANASONIC – LEADING THE WAY IN HEATING & COOLING With more than 30 years of experience, selling to more than 120 countries around the world, Panasonic is unquestionably one of the leaders in the heating and cooling sector. HISTORY OF AIR CONDITIONING GROUP Panasonic starts with a desire to create things of value. As hard work and dedication results in one innovative product after another, the fledgling company takes its first steps towards becoming the electronics giant of today. 4 1936 1958 1973 1975 First electric Fan with Automatic Oscillation (36 cm table top model). First room air conditioner launched for domestic installation. Prior to this date, air conditioners were large and only for commercial use. Panasonic developed the first compact air conditioner for windows; it was lightweight and easy to install, improving the quality of life in Japanese homes. 1,100 units were sold in Japan in the first year, and just two years later, in 1960, this figure rose to 230,000. Panasonic launches the first highly efficient air-to-water heat pump in Japan. Panasonic becomes the first Japanese air conditioner manufacturer in Europe. EDITORIAL The company is also a world leader in innovation as it has filed more than 91539 patents to improve its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In all, the company has produced more than 200 million compressors and its products are manufactured in 294 plants which are located all over the world. You can be assured of the extremely high quality of Panasonic’s heat pumps. This wish to excel has made Panasonic the international leader in heating and air conditioning solutions of turnkey for homes, medium-sized buildings such as offices and restaurants, and large-scale buildings. These offer maximum effectiveness, comply with the strictest environmental standards and meet the most avant-garde construction requirements of our time. At Panasonic we know what a great responsibility it is to install heating and cooling systems. Because offering you the best solutions in heating and cooling matters. PANASONIC EUROPE Panasonic is committed to offering our customers innovative products in the heating and cooling market across Europe, which not only meet but exceed their requirements. Key to success is Panasonic’s investment in R&D, manufacture and training to ensure innovative, cutting edge products and investment in our distribution channels and partners so that these products are accessible in Europe. Panasonic has developed a comprehensive network across Europe of training centers and training academies for installers, design offices and service teams in all major countries. PANASONIC FACTORIES AND R&D DEPARTMENT There is a close relationship between R&D innovation and good manufacturing processes, and so Panasonic has placed its R&D facilities very close to its manufacturing bases. This ensures good integration between all divisions to deliver high quality and reliable solutions to our markets. 2002 2008 2010 2011 2012 The Ion and Oxygen Generator — two of the most important contributions to air conditioning systems. Etherea new concept of air conditioning systems: high efficiency and high performances with a great design. Etherea also includes a very innovative air quality sensor and air purifier in order to enjoy healthy air at home at all times. New Aquarea Panasonic has created Aquarea, an innovative new, low-energy system, designed to help you enjoy ideal temperatures and hot water in your home, even with extreme outdoor temperatures. Aquarea cools or heats to ensure maximum comfort. Aquarea is far cleaner, safer, cheaper and environmentally friendly than alternatives using gas, oil and other electrical systems. New Eco i VRF solution The new Panasonic VRF solution for big buildings is the most efficient in the industry in more than 74% of combinations. ECO i satisfies the most demanding standards required by design offices, architects, owners and installers. New GHP units Pansonic’s gas-driven VRF systems are ideal for projects where power restrictions apply. In 2012, Panasonic extends the Gas Heat Pump range with a new GHP line-up, new GHP G Power (electricity production) and the new Chiller Units. 5 LIVING ECO-FRIENDLY Panasonic is globally committed to developing environmentally-conscious products in the following three aspects: global warming prevention, effective resources utilisation and chemical substances management. In particular, we have been striving to increase a rate of products with industry-leading energy efficiency and phase out those with low performance, with the aim of contributing to the prevention of global warming. In the ‘eco ideas’ House, which embodies a lifestyle with virtually zero CO 2 emissions and that will be realised in three to fi ve years into the future, we are proposing wide-ranging ideas that create comfortable lifestyles with minimum energy consumption, as well as presenting products and services that make full use of our original environmental technologies. Furthermore, to face the challenge of stepping up to the new field from the enhancement of products’ energy efficiency, Panasonic is promoting the development of energy-saving equipment such as heat pumps, fuel cells and solar power generators as well as energy-storing devices. 6 EDITORIAL Ideas for a Cleaner Future Panasonic is committed to developing environmentally-conscious products from three aspects, such as prevention of global warming, effective utilisation of resources and chemical substances management. ENERGY MANAGEMENT CREATE ENERGY The SEG (Smart Energy Gateway) connects residential energy sources with smart appliances with a wireless network and a server. Solar Cells and Fuel Cells to create energy more cleanly and efficiently PHOTOVOLTAIC LED LAMP AIR-CONDITIONER WASHING MACHINE REFRIGERATOR ENERGY MANAGEMENT SYSTEM VENTILATION SYSTEM FUEL CELL STORAGE BATTERY HEAT PUMP STORE ENERGY SAVE ENERGY Residential lithium-ion batteries for a stable energy supply From top resource savings to efficient heating – Panasonic offers many eco-friendly appliances: LED/ ESL, ERV, Air Conditioner, Washing Machine, Fridge, Heat Pump In an era when the world is tackling the reduction of CO 2 emissions, Panasonic proposes a lifestyle with virtually zero CO 2 emissions throughout the entire home. CO 2 emissions are thoroughly reduced by enhancing energy-saving performance of home appliances and utilising building materials with high insulation performance. And energy required will be supplied by creating and storing energy by a combination of solar power generators, fuel cells and storage batteries. The Panasonic energy management system realises a lifestyle with virtually zero CO2 emissions by linking these benefits together and smartly controlling all energy use. Meanwhile, intelligent use will also be made of natural elements such as air, light, water and heat to realise a more comfortable lifestyle. Experience an ecological and comfortable lifestyle that only Panasonic can present. 7 REALISING ECO-CONSCIOUS SOLUTIONS IN ENTIRE TOWNS 8 TIANJIN ECO-CITY Panasonic is taking part in a pioneering project by China and Singapore to create the Tianjin Eco-City, some 40 km from Tianjin city centre and 150 km from Beijing. Designed to be practical, replicable and scalable, the Tianjin Eco-city will demonstrate the determination of both countries in tackling environmental protection, resource and energy conservation, and sustainable development, and serve as a model for sustainable development for other cities in China. By 2020, there will be around 30 square kilometres of city capable of accommodating a population of around 400,000. EDITORIAL HOME ENERGY MANAGEMENT SYSTEM Panasonic is supplying each of the houses built in Tianjin Eco-City with a mini-VRF air conditioning system with Home Energy Management System (HEMS). The HEMS will be central to saving energy in homes. By linking a whole range of domestic appliances, solar power generation equipment, electric vehicle chargers, storage batteries and other devices, the HEMS shows the amount of energy being used in the home. The system will indicate whether or not energy-saving goals are being achieved and will display advice on where further savings could be made. By using easily-read displays on all screens throughout the home, homeowners will become more conscious of energy-saving activities and adopt a more natural and eco-friendly lifestyle. FUJISAWA SUSTAINABLE SMART TOWN Panasonic is converting its former factory site in Fujisawa City in Japan, 50 km west of Tokyo, into a smart town deploying services and energy systems based on Panasonic’s eco ideas for green lifestyles. Panasonic is working in partnership with eight other companies and Fujisawa City to build an innovative smart town. The developers, manufacturers and service providers will work closely together throughout every phase of the project, from the master planning stage to actual operation of the town that will have about 1,000 households spread over 19 hectares. Homes will employ the full range of Panasonic’s most advanced systems for energy production, storage and management. Houses will be fully selfsufficient by generating power from efficient solar modules and fuel cell systems, with energy stored in powerful lithium-ion batteries. Low energy lighting, air conditioning and household appliances will be interconnected via a computer system, and televisions and PCs will be used to display energy consumption and tips on savings. 9 PANASONIC PROFESSIONAL Panasonic has an impressive range of support services for designers, specifiers, engineers and distributors working in the heating and cooling markets. SOFTWARE Panasonic provides bespoke software helping system designers, installers and dealers to very quickly design and size systems, create wiring diagrams and issue bills of quantities at the push of a button. ECOI VRF DESIGNER The VRF Designer Software is very easy to use. By using it, engineers can develop projects quickly, by either using the drag and drop icons or the project wizard. It comes fully loaded with all appropriate Panasonic product details and is designed with flexibility in mind so that several different system designs can be created within one project. The program will check system designs and correction factors are automatically applied to indoor unit capacities, depending on height differences, piping lengths, indoor/outdoor capacity ratio and design conditions. VRF Designer will also calculate any additional amounts of refrigerant that may be required, based on configuration and piping lengths. Existing projects can easily be modified or even extended at a later stage. Reports can be exported and printed showing piping and wiring diagrams, power supply diagrams as well as bill of quantities. 10 AQUAREA DESIGNER This program allows HVAC designers, installers and distributors to identify the correct heat pump for a particular application from Panasonic’s Aquarea range, calculate the savings compared to other heat sources and very quickly calculate CO2 emissions. Using Panasonic’s Aquarea Designer, projects can be developed simply and easily, by either using the Quick Design or Expert Design options. Each allows the user to build up the project data in a simple step-by-step process and choose to output reports (in either Quick or Large formats) as HTML files or as print outs. Aquarea Designer will calculate the project’s energy costs in terms of hot water, heating and pumping. It will show the equipment running times and calculate the COP (coefficient of performance). It then allows the designer to show clients a comparison with other equipment options such as heating by conventional gas-fired boilers, oil systems, wood, standard electric heating and electric night storage heaters. This compares running costs, initial investment costs and maintenance costs. The comparison can also be made for CO2 emissions and savings. iPAD APP For a quick and easy introduction to the Aquarea Heat Pump range, the iPad app can be used to show clients the benefits of this energy-efficient heating and hot water system. EDITORIAL NEW PRO CLUB PRO Club PANASONIC PRO CLUB THE PANASONIC PRO-ACADEMY OPENS ITS DOORS Panasonic announces a new initiative for all professionals involved in the heating and cooling business - the Panasonic PRO Club (www.panasonicproclub.com). This exciting new portal provides distributors, installers, engineers and specifiers with a direct communication channel with one of the industry’s major manufacturers. The website contains a wealth of information from the latest versions of Panasonic’s Aquarea and Etherea Design Software, to Technical Documentation, Catalogues and Images for the company’s wide range of heating and cooling systems - all in an easy to navigate and use website. Also, registered users will be able to access news regarding special promotions and take advantage of these offers, as well as access helpful business advice such as ideas and guidelines for showroom decoration or van livery featuring Panasonic logos and display material. Panasonic takes its responsibility to its distributors, specifiers and installers seriously and has developed a comprehensive Training Programme. The Panasonic Pro-Academy encompasses the traditional hands-on approach, as well as embracing today’s technology to offer an eLearning facility available 24 hours, 7 days a week! www.panasonicproclub.com or connect simply with your smartphone to the proclub using this QR: NEW TRAINING COURSES COVER THREE LEVELS Design, installation, and commissioning & trouble-shooting Training courses include: · VRF ECOi · Aquarea air source heat pumps (MCS accredited) · GHP (2012) The courses are offered on site at Panasonic’s premises across Europe as well as via the Panasonic ProClub eLearning site. The Training Centres display Panasonic’s latest product range and give delegates an opportunity to get hands-on experience with the latest controllers, indoor and outdoor units from the VRF ECOi, Etherea, GHP and Aquarea ranges. 11 NEW 2012 AQUAREA’S NEW AIR-TO-WATER HEAT PUMP FOR RESIDENTIAL APPLICATIONS Offering capacities from 3kW to 16kW, the Aquarea Heat Pump Range is the biggest line-up on the market, designed to meet all your heating and cooling demands. Cost-effective and environmentally friendly. AQUAREA’S NEW AIR-TO-WATER HEAT PUMP FOR RESIDENTIAL COMMERCIAL, AND CHILLER APPLICATIONS Up to 80 kW capacity from an easy-to-install system providing impressive efficiency, even at outdoor temperatures as low as -20°C. * O * * European Quality Label for Heat Pumps ehpa * Not all products certified. As the certification process is on-going and the list of certified products constantly changing, please check for latest details on the official websites. 12 AQUAREA PANASONIC’S NEW AQUAREA AIR-TO-WATER SYSTEM PROVIDES MAXIMUM EFFICIENCY AND CAPACITY EVEN AT -15 °C Panasonic’s new Aquarea system, based on high-efficiency heat pump technology, not only heats your home and hot water, but also cools your home in summer with incredible operating performance. This creates perfect comfort whatever the weather conditions, even at outdoor temperatures as low as -15°C. Panasonic new heat pumps are designed in response to the new demand for low consumption housing, with high efficiency and low running cost's. high efficiency heating environmentally friendly refrigerant R410A INVERTER+ SYSTEM The A Inverter+ system provides energy savings of up to 30% compared to non inverter models. Both you, and nature, wins! REFRIGERANT R410A / R407C R410A / R407C offers optimal performance and involves no environmental cost since it does not harm the ozone layer. down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE UP TO -20°C IN HEATING MODE The air conditioner works in heat pump mode with an outdoor temperature as low as -20ºC. solar panels connection domestic hot water RETROFIT SOLAR KIT DHW RENOVATION Our Aquarea heat pumps can be connected to an existing or new boiler for optimum comfort even at very low outdoor temperatures. SOLAR KIT For even greater efficiency, our Aquarea heat pumps can be connected to photovoltaic solar panels with an optional kit. DHW With Aquarea you can also heat your domestic hot water at a very low cost with the optional hot water cyclinder. 5 year compressor warranty 5 YEARS WARRANTY We guarantee the compressors in the entire range for five years. 13 "GREEN" HIGH-EFFICIENCY HEATING WITH PANASONIC'S NEW AIR-TO-WATER HEAT PUMP SYSTEMS At the forefront of energy innovation, Aquarea is resolutely positioned as a “green” heating and air-conditioning system. Aquarea is part of a new generation of heating and air-conditioning systems that use a renewable, free energy source – the air – to heat or cool the home and to produce hot water. The Aquarea heat pump is a much more flexible and cost-effective alternative to a traditional fossil fuel boiler. We are surrounded by an endless supply of free energy: supplied by the sun and present in all spheres of our environment, the air, the ground, the groundwater... An ideal heating solution for both new and old properties: · A wide range from 3 to 16 kW, single and three phase, mono-bloc and bi-bloc · 3 Versions: - The Standard Heat Pump - The High Temperature Heat Pump (output water temperature of 65°C) - The Total Capacity Heat Pump even at -15ºC · The High-efficiency Heat Pump which operates at outside temperatures as low as –20ºC · Reduces energy costs with its COP of 4.74* · Reduces energy consumption and CO2 emissions · Provides cooling in summer · Highly flexible: - Connects to an existing heating system - Connects to photovoltaic solar panels Thus, Panasonic’s Aquarea system is an air/water heat pump system that uses energy from the outdoor air and transmits them via a heat exchanger to the water used to heat your home in winter, in addition, some Aquarea models can even be used to cool your house in summer time and produce hot water all year round. Heat pumps enable us to recover this free, inexhaustible energy and to harness its power to heat our homes. These systems have the huge advantage, apart from reducing your electricity bill, of saving fossil fuels and at the same time limiting greenhouse gas emissions*. * We note that ADEME (French environmental and energy management agency) encourages consumers to choose heating and cooling systems that use heat pump systems. * COP: energy efficiency in heating mode. COP of 4.74 for the 9kW WH-MDF09C9E8 or WH-UD09CE8 models at an outside temperature of 7 ºC, and for water. input and output temperatures of 30 °C and 35 °C (according to EN 14511-2) We note that ADEME (French environmental and energy management agency) encourages consumers to choose heating and cooling systems that use heat pump systems. 14 AQUAREA UUPP TO TO 78% eenergy ener ene nerg nerg rgy gyy ssavings av avin ingss1 ing NEW 3 & 5 kW UP TO 78% ENERGY SAVINGS* Panasonic’s Aquarea heat pump provides savings of up to 78% on heating expenses compared with electrical heaters. For example, the Aquarea 9kW system has a COP of 4.74. This is 3.74kW more than a conventional electrical heating system which has a maximum COP of 1. This is equivalent to a 78% saving. Consumption can be further reduced by connecting photovoltaic solar panels to the Aquarea system. AQUAREA UP TO 78% ENERGY SAVINGS* GAS BOILER ELECTRICAL HEATING OIL BOILER 0,78 kW 1kW 0,9kW 1kW 0,9kW 1kW 1kW GAS HEAT OIL HEAT ELECTRICITY HEAT RENEWABLE ENERGY 0,22kW ELECTRICITY 78% OUTDOOR ENERGY 1kW HEAT 22% ELECTRICITY OTHER HEATING SYSTEMS POWER INPUT / ENERGY CONSUMPTION POWER OUTPUT / HEATING CAPACITY (KW) * Up to 78% of the heat produced by a heat pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb / Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30 °C Water output temperature: 35 °C 15 PANASONIC HAS DESIGNED A COMPLETELY NEW LINE-UP TO GIVE THE BEST TO OUR CUSTOMERS THERE ARE SEVERAL TYPES OF HEAT PUMP AVAILABLE: The mono-bloc system The bi-bloc system This only has an outdoor unit. The installation doesn’t require a refrigerated connection and is only connected to the heating system. This system is made up of an outdoor unit and a hydraulic module, normally located in the utility room or garage. * * * * * Tank Optional 16 * Tank Optional AQUAREA AQUAREA INCREASE LINE-UP! · New 3 and 5 KW Bi-bloc for low energy homes · New 6 and 9 KW Mono-bloc Heat Pumps for low energy homes · New line-up of high temperature Heat Pumps (output water temperature of 65°C) WHICH PRODUCT FOR WHICH APPLICATION? 4.74* COP 100% output water high efficiency AQUAREA HIGH CONNECTIVITY 65ºC capacity at -15°C HIGH TEMP HEAT PUMP AQUAREA T-CAP AQUAREA HIGH CONNECTIVITY AQUAREA HT AQUAREA T-CAP For a house with low temperature radiators or under-floor heating, our high connectivity Aquarea heat pump is a good solution. This solution can work as a stand-alone unit or can be combined with a gas- or oil-fired depending on requirements. For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution is the most appropriate as the Aquarea HT provides output water temperatures of 65°C even at -15°C. Aquarea HT is able to deliver hot water to 65°C with the Heat Pump alone. If the most important aspect is to keep nominal heating capacities even at temperatures as low as -7°C or -15, select the Aquarea T-CAP. This ensures that there is always enough capacity to heat the house without help from an external boiler – even at extremely low temperatures. Aquarea T-CAP always has high efficiency and high heating capacity even at extremely low temperatures. With Aquarea T-CAP, you can always enjoy high savings. AQUAREA T-CAP AND HIGH CONNECTIVITY COMPARISON AQUAREA T-CAP MAINTAINS THE NOMINAL CAPACITY TILL -15°C (EXAMPLE FOR 12KW) AQUAREA T-CAP AND HIGH CONNECTIVITY HAVE EXTREMELY HIGH EFFICIENCY EVEN AT -15°C 5 4,5 4 3,5 12 3 10 2,5 8 2 6 2,5 4 1 2 0,5 Aquarea T-CAP COP is displayed Aquarea High connectivity COP is displayed 0 0 +7ºC -7ºC -15ºC +7ºC -7ºC -15ºC * Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C; outside temperature: +7°C. 17 NEW AQUAREA 3 AND 5 KW BI-BLOC AND 6 AND 9 KW MONO-BLOC AIR TO WATER HEAT PUMP MAXIMUM SAVINGS, MAXIMUM EFFICIENCY, MINIMUM CO2 EMISSIONS, MINIMUM OF SPACE NEW 2012 18 Panasonic has designed the new Aquarea Bi-bloc and Monobloc heat pumps for homes which have high performance requirements. Whatever the weather, Aquarea will always give you maximum efficiency, even at -20°C! The New Aquarea is easy to install on new or existing installations, in all types of properties. AQUAREA W k 9 6/ , 5 / W OMES 3 O L NEW FUOMRPTION H S CON down to -20ºC in heating mode OUTDOOR TEMPERATURE BI-BLOC APPLICATION EXAMPLE LOW CONSUMPTION HOMES + SANITARY HOT WATER COP COMPARISON (ELECTRICAL HEATER WITH PANASONIC HEAT PUMP) OUTSIDE 1kW 1kW 1kW INSIDE HOUSE 4,41kW MONO-BLOC APPLICATION ELECTRICAL HEATER PANASONIC HEAT PUMPS EXAMPLE HEATING + SANITARY HOT WATER POWER INPUT / ENERGY CONSUMPTION POWER OUTPUT / HEATING CAPACITY (KW) Sanitary tank (200 l or 300 l) * The comparison is made on nominal manufacturer values based on the following conditions. Rating conditions: Heating: Inside air temperature: 20°C Dry Buld / Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TECHNICAL BENEFITS · Plug and play heating system · No indoor box needed ( for 6 and 9 KW Monobloc) · Extremely compact system · 3 kW heater included · High efficiency even at -20°C OUTSIDE TECHNICAL AREA INSIDE HOUSE EXAMPLE HEATING PLUG AND PLAY SYSTEM TECHNICAL ELEMENTS · Mono-bloc unit includes: - Heat exchanger - 3 speed hot water circulator - 6-litre vessel - Safety valve - Pressure gauge - 3 kW electrical heater OUTSIDE INSIDE HOUSE 19 + HIT Photovoltaic solar panel from Panasonic 20 HEAT PUMP + PHOTOVOLTAIC PHOTOVOLTAIC SOLAR PANELS: THE BEST SOLUTION FOR BIG SAVINGS Panasonic Aquarea heat pumps can easily be integrated with photovoltaic solar panels in order to achieve maximum energy savings, cut fuel bills, and to reduce C02 emissions. AQUAREA NEW 2012 Fan coil (heating and cooling) Radiator (heating) Photovoltaic solar panel Floor heating, panel heating Hydraulic module (water heat exchanger) Outdoor unit Hot water Hot water storage tank HOW DOES THE AQUAREA SYSTEM WORK ? PHOTOVOLTAIC SOLAR PANELS FOR EVEN MORE SAVINGS An air to water heat pump system uses heat energy present in the outdoor air to heat the house, cool it and also to produce hot water. The Aquarea system therefore uses free energy to heat or cool your home. It only consumes electricity to operate the compressor, the electronics, the pumps and in the event of very low temperatures, the electric elements. The result is very high efficiency and real energy savings. Combining photovoltaic solar panels with your heat pump can help to further reduce your electrical consumption and CO2 emissions. Additionally, with the unique HIT photovoltaic solar panel technology from Panasonic, you can produce more electricity per square meter, helping you to increase your energy savings still further. SOLAR Refrigerant Reversible heat pump Example : with split-system HWC Water Environmentally-Friendly Solar Cell More Clean Energy. HIT can generate more clean Energy than other conventional crystalline solar cells. HWC Hydraulic module HIT cell technology The Panasonic HIT (Heterojunction with Intrinsic Thin layer) solar cell is made of a thin mono crystalline silicon wafer surrounded by ultra-thin amorphous silicon layers. This product provides the industry's leading performance and value using state-of-the-art manufacturing techniques. Radiators Radiant floor 21 high INVERTER+ COMPRESSOR FOR EVEN GREATER EFFICIENCY efficiency heating Panasonic has clearly demonstrated it status as lead in this field with over 100 million compressors supplied and the excellent quality and reliability of its heat pumps. With a Panasonic Inverter+ compressor, you can save up to 30% energy compared to a traditional system with no inverter. With a Panasonic Inverter compressor, the heat pump is always producing heat with the maximum of efficiency and adapting the capacity to the element. THE ADVANTAGES OF INVERTER AIR CONDITIONERS Comparing Inverter and non-Inverter air conditioners. HEAT IN THE LIVING ROOM (UNCOMFORTABLE) COMFORT THE LIVING ROOM (COMFORTABLE) COLD IN THE LIVING ROOM (UNCOMFORTABLE) NO INVERTER Slow to start. Takes longer to reach the temperature set point. 22 INVERTER Rapidly reaches the desired temperature. NO INVERTER The temperature oscillates between the two extremes and never stabilises. The temperature falls and then rises quickly, leading to a consumption peak. INVERTER Adjusts the temperature: more comfort and greater savings. Keeps the temperature comfortable all the time. AQUAREA COP 4,74 COMFORT, SAVINGS AND POWER EVEN AT VERY LOW TEMPERATURES HEAT PUMPS: MORE EFFICIENT THAN OTHER HEATING SYSTEMS Panasonic’s inverter+ system After quickly reaching the selected temperature, the Inverter+ system will gradually adjust the power in order to maintain a constant temperature. Thus, there will not be any sudden changes in temperature and the capacity of the power also guarantees a constant and pleasant temperature, even when the outside temperature changes. Maximum efficiency even at extremely low temperatures The Aquarea range has been specially designed to provide maximum efficiency even at extreme temperatures when compared with electrical heaters or gas boilers. BEST EFFICIENCY COMPARED TO OTHER HEATING EFFICIENCY SYSTEMS SDF/SDC/MDF/MDC Heating Capacity at +7°C (kW) COP at +7°C with heating water temperature at 35°C Heating Capacity at +2°C COP at +2°C with heating water temperature at 35°C Heating Capacity at -7°C (kW) COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C (kW) COP at -15°C with heating water temperature at 35°C SXF/SXC/MXF/MXC Heating Capacity at +7°C (kW) COP at +7°C with heating water temperature at 35°C Heating Capacity at +2°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C (kW) COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C (kW) COP at -15°C with heating water temperature at 35°C 7 kW 7 4,4 6,55 3,31 5,15 2,65 4,6 2,3 9 kW 9 4,74 9 3,53 9 2,81 9 2,54 9 kW 9 4,74 9 3,53 9 2,81 8,3 2,55 12kW 12 4,67 11,4 3,4 10 2,7 8,9 2,43 14 kW 14 4,5 12,4 3,32 10,7 2,62 9,5 2,35 Pan Panasonic heat pumps have a maximum COP of 4.74 at + 7°C which makes them much more efficient than fossil fuel fired boilers, gas mak boilers boil l and electrical heaters. 16 kW 16 4,23 13 3,25 11,4 2,55 10,3 2,33 4,74 12 kW 12 4,67 12 3,4 12 2,7 12 2,4 Fuel fired boiler Gas boiler Aquarea Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C. AQUAREA DESIGNER Using Panasonic’s Aquarea Designer, projects can be developed simply and easily, by either using the Quick Design or Expert Design options. Each allows the engineer to build up the project data in a simple step-by-step process and choose to output reports (in either Quick or Large formats) as HTML files or as print outs. To create the useful reports, project data is input, including: · Heated area · Heating requirement · Heating flow and return temperatures · Climate data (from a simple drop-down menu) including outdoor design temperature · Type of hot water tank, storage capacity and hot water target temperature. Aquarea Designer will calculate the project’s energy costs in terms of hot water, heating and pumping. It will show the equipment running times and calculate the Annual COP (coefficient of performance). It then allows the designer to show clients a comparison with other equipment options such as heating by conventional gas-fired boilers, oil systems, wood, standard electric heating and electric night storage heaters. This compares running costs, initial investment costs and maintenance costs. The comparison can also be made for CO2 emissions and savings. Available to download from www.panasonicproclub.com 23 WHAT MAKES THE AIR-TO-WATER HEAT PUMP WORK · The outdoor unit: this captures the free energy from the outdoor air and brings it into the house by means of the hydraulic module. This free energy are transported to the hydraulic module using an environmentally-friendly refrigerant gas with a high thermal exchange coefficient (R407C). · Via the hydraulic module, with control panel, the temperature inside the house can be controlled and efficiency maximised. It has a heat exchanger which transmits the energy contained in the refrigerant coming from the outdoor unit to the water used for the home's heating and hot water. The hydraulic module manages priorities in terms of heating and hot water production. This hydraulic module is situated inside the property in the case of the bibloc system or in the outdoor unit in the case of the mono-bloc system. · The hot water cylinder heats the hot water. It is made of stainless steel, which guarantees it a very long life. It is also fitted with a 3 kW element to ensure maximum comfort when outdoor temperatures are very low. The heater, situated at the top of the cylinder, guarantees maximum efficiency and faster heat-up. 24 A 3-way valve for the hot water cylinder connection is supplied with the hot water cylinder. · Other necessary or optional features (not provided by Panasonic): - Room temperature thermostat, which can be connected to the Aquarea system to ensure optimum room temperature conditions. - Solar kit, to connect photovoltaic solar panels for even greater efficiency. · A 3kW immersion heater is included within the hot water tank to ensure: - Maximum comfort - Maximum efficiency and more for ensure protection against the legionella virus TWO OR THREE EARTH LEAKAGE CUT-OUTS The Aquarea hydraulic module has differential cut-off ensuring maximum safety in the event of a short circuit: - 2 differential cut-outs: 3 and 5 and 6 and 9 kW - 3 differential cut-outs: 12, 14 and 16 kW AQUAREA THE CONTROL PANEL EASY PROGRAMMING OF THE CONTROL PANEL The control panel allows accurate temperature control based on the outdoor temperature, providing maximum efficiency and comfort. The control panel controls the heating temperature and the hot water cylinder temperature very simply. The primary circuit temperature is controlled based on the outdoor temperature. Who will adjust the control parameters through the remote control during the commissioning of the system as is shown in the diagram below. Your heating specialist must also select the type of operation you need: heating priority or hot water cylinder priority. THE HYDRAULIC MODULE Heating feed R1 1/4 Water Temp. OD(LO) = Setting Of Low Outdoor Ambient Temperature OD(HI) = Setting Of High Outdoor Ambient Temperature Heating return R1 1/4 Drainage W(LO) = Setting Of High Water Temperature at Low outdoor air temperature Wire inlet W(HI) = Setting Of Low Water Temperature at High outdoor air temperature Gas refrigerant connection 5/8 Liquid refrigerant connection 1/4 -3/8 W(HI) W(LO) OD(LO) OD(HI) Outdoor Temp. Safety valve Condenser Interface card EASY READING OF CONTROL OF WATER PRESSURE 10l Expansion tank Overload protection Flow controler Pressure gauge Connection plate 3-speed hot water circulator 3 kW / 9 kW* Electric element Pressure gauge The water pressure must be between 0.055 and 0.29 MPa Refrigerated Links connection with outdoor unit Water connection * 3 kW for 7 and 9 kW, 6 kW for 12, 14, 16 kW single-phase 9 kW for 12, 14, 16 kW three-phase 25 NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE By Intesis (www.intesis.com) CONTROL YOUR HEAT PUMP WITH YOUR SMART DEVICE -SMARTPHONE & INTERNETPanasonic has always offered its customers the most efficient Heat Pumps and Air Conditioners. Now it has taken a step forward and presents with and presents, in partnership with Intesis, the IntesisHome - the most advanced, the most advanced service taking advantage of the latest Cloud Technology to manage your climate system from anywhere in the world. Control your environment from your iPad, iPhone, any Android device or from a PC with Internet access using IntesisHome®. Offering the same functions as if you were at home: start/stop, Mode Operation, Set Temperature, Room Temperature etc. Experience the new, advanced functionality provided by IntesisHome® to achieve the best comfort and efficiency with the lowest energy consumption. 26 SMART DEVICE VIA SMARTPHONES & INTERNET INTE IN TERN RNET ET VIA VI A SM SMAR ARTP TPHO HONE NES S& SMAR SM ART AR T DE DEVI VICE VI CE PUMP PU MP WIT ITH H TH THE E CONT CO NTRO NT ROL RO L YO YOUR UR HEA EAT T READY iPHONE & ANDROID NEW AQUAREA TAKE CONTROL FROM WHEREVER YOU ARE! PC iPhone ANDROID INTERNET SERVICE IN THE CLOUD STREET OFFICE INTERFACE WIFI WORK GYM AQUAREA ROUTER WIFI ADVANCED SERVICE HOSTED IN THE CLOUD THAT PROVIDES ACCESS FROM ANYWHERE TO YOUR AC SYSTEM. FUNCTIONALITY INSTALLATION · Remote control: On/Off, Mode, Temp. Setting, etc. · Scheduler calendar, Energy Saving functions, Preset configuration features · Maintenance functions: · Dirty Air Filter alerts · Technical Service network · Error list · ECO advices. · Multi-lingual application · Easy installation. · Videos and Manuals from www.intesishome.com · Helpline (Phone & Internet). · Automatic updates. REFERENCE · CZ-HI-Aquarea. IntesisHome for Aquarea 27 CONNECTIVITY GREAT FLEXIBILITY FOR INTEGRATION INTO YOUR KNX / ENOCEAN / MODBUS PROJECTS ALLOWS FULLY BI-DIRECTIONAL MONITORING AND CONTROL OF ALL THE FUNCTIONING PARAMETERS The Intesis interface has been designed specifically for Panasonic and provides complete monitoring, control and full functionality of the entire Aquarea line-up from KNX, EnOcean and Modbus installations. Interfaces must purchased at Intesis. More information on www.intesis.com To know more about compatibility of Panasonic Heat pumps with Intesis interfaces, please visit: http://www.intesis.com/pdf/IntesisBox_PA-AC-xxx-1_AC_Compatibility.pdf 28 AQUAREA INTERFACE TO CONNECT AQUAREA TO KNX INTESIS PART Nº: PA-AW-KNX-1i Intesis new Aquarea-KNX interface allows monitoring and control, fully bi-directionally, all the functioning parameters of Aquarea control from KNX installations. · Small dimensions. · Quick installation and possibility of hidden installation. · External power not required. · Direct connection to the unit. · Fully KNX interoperable. Control and monitoring, from sensors or gateways, of the internal variables of the indoor unit and error codes and indication. · Aquarea unit can be controlled simultaneously by the remote control of the Aquarea unit and by KNX devices. · 4 Binary inputs, they work as standard KNX Binary Inputs (On/Off, Send value, Lights, Blinds, etc) as well as being used to control the Aquarea unit directly. · Manual of installation: www.intesis.com 4 x binary inputs PA-AC-KNX-1i Any standar KNX device INTERFACE TO CONNECT AQUAREA TO ENOCEAN INTESIS PART Nº: PA-AW-ENO-1i / PA-AW-ENO-1iC Intesis new Aquarea-EnOcean PA-AW-ENO-1i interface allows monitoring and control, fully bi-directionally, all the functioning parameters of the Aquarea control from EnOcean installations. · Small dimensions. · Quick installation. · External power not required. · Direct connection to the Aquarea unit using the same parameters as on the control. · Fully EnOcean interoperable. Control and monitoring, from sensors or gateways, of the internal variables of the indoor unit and error codes and indication. · Aquarea unit can be controlled simultaneously by the remote control of the Aquarea unit and by EnOcean devices. · 4 binary inputs. They work as standard EnOcean binary inputs as well as being used to control the Aquarea unit directly. ·Manual of installation: www.intesis.com 4 x binary inputs PA-AC-ENO-1i PA-AC-ENO-1iC EnOcean Switch EnOcean RC Keycard Movement sensor INTERFACE TO CONNECT AQUAREA TO MODBUS INTESIS PART Nº: PA-AW-MBS-1 Intesis new Aquarea-Modbus RTU Slave interface allows monitoring and control, fully bi-directionally, all the functioning parameters of Aquarea control from Modbus installations. · Small dimensions. · Quick installation and possibility of hidden installation. · External power not required. · Direct connection to the unit. · Fully Modbus interoperable. Control and monitoring, from any BMS or PLC Modbus Master, of internal variables of the indoor unit and error codes and indication. · Aquarea unit can be controlled simultaneously by the remote control of the Aquarea unit and by Modbus Master device. ·Manual of installation: www.intesis.com PA-AW-MBS-1 MODBUS Building Management System 29 HP BI-BLOC APPLICATION EXAMPLES HP BI-BLOC + RADIATORS HP BI-BLOC + BOILER + RADIATORS + FAN COILS + SOLAR KIT HP BI-BLOC + ACS + BOILER + RADIATORS HP BI-BLOC + ACS+ BUFFER TANK + RADIATORS + FLOOR HEATING + SOLAR KIT HP BI-BLOC + ACS+ RADIATORS HP BI-BLOC + RADIATORS + BUFFER TANK + FLOOR HEATING HP BIBLOC + ACS + BUFFER TANK +FAN COIL + FLOOR HEATING + RADIATORS HP BI-BLOC 3 AND 5 KW .LOW CONSUMPTION + SANITARY HOT WATER + BUFFER TANK + RADIATORS + FLOOR HEATING 30 AQUAREA HP MONO-BLOC APPLICATION EXAMPLES HP MONO-BLOC + BUFFER TANK + BOILER + RADIATORS + SWIMMING POOL HP MONO-BLOC + BI-BLOC + ACS + RADIATORS + FLOOR HEATING HP MONO-BLOC + BUFFER TANK + ACS +BOILER + RADIATORS + SWIMMING POOL HP MONO-BLOC 6 AND 9 KW .EASY TO INSTALL, WITHOUT ANY BOX INSIDE THE HOUSE + BUFFER TANK + ACS + FLOOR HEATING HP MONO BLOC + BUFFER TANK + ACS + BOILER + RADIATORS HP MONO-BLOC 6 AND 9 KW .EASY TO INSTALL, WITHOUT ANY BOX INSIDE THE HOUSE + RADIATORS + FLOOR HEATING 31 AQUAREA LINE-UP! NEW 2012 FIGURE 1 (F1) FIGURE 3 (F3) FIGURE 2 (F2) NEW 2012 FIGURE 4 (F4) FIGURE 5 (F5) LINE UP Aquarea High Connectivity Bi-Bloc Single phase Heating only Heating and cooling Three phase 3KW 5KW WH-SDF03E3E5* (F1) WH-UD03EE5 WH-SDF05E3E5* (F1) W WH-UD05EE5 W WH-SDC03E3E5* WH-UD03EE5 NEW 2012 (F1) N W NEW 2012 WH-SDC05E3E5* W WH-UD05EE5 W 6KW 7KW WH-SDF07C3E5 WH-UD07CE5-A (F2) NEW 2012 (F1) WH-SDC07C3E5 WH-UD07CE5-A (F2) N W NEW 2012 Heating only Heating and cooling Mono-Bloc Single phase Heating only WH-MDF06D3E5 (F5) Heating and cooling WH-MDC06E3E5 ** (F5) NEW NEW 2012 2012 Three phase Heating only Heating and cooling Aquarea T-CAP Bi-Bloc Single phase Heating only Heating and cooling Three phase Heating only Heating and cooling Mono-Bloc Single phase Heating only Heating and cooling Three phase Heating only Heating and cooling Aquarea High temperature Bi-Bloc Single phase Heating only Three phase Heating only Single phase Heating only Three phase Heating only VRF ECOi + Water Heat Exchanger Three phase Heating and cooling GAS VRF ECOg + Water Heat Exchanger Three phase Gas. Heating and cooling Mono-Bloc AQUAREA PRO Low connectivity : control of 3 way valve, tank heater On/Off signal, tank thermostat signal reception, On/Off from external control, weekly timer High connectivity : Low connectivity + solar pannels connection, room thermostat connection 32 AQUAREA NEW NEW 2012 2012 FIGURE 6 (F6) 9KW 12KW 14KW 16KW WH-SDF09C3E5 WH-UD09CE5-A (F2) WH-SDF12C6E5 WH-UD12CE5-A (F3) WH-SDF14C6E5 WH-UD14CE5-A (F3) WH-SDF16C6E5 WH-UD16CE5-A (F3) WH-SDC09C3E5 WH-UD09CE5-A (F2) WH-SDC12C6E5 WH-UD12CE5-A (F3) WH-SDC14C6E5 WH-UD14CE5-A (F3) WH-SDC16C6E5 WH-UD16CE5-A (F3) WH-SDF09C3E8 WH-UD09CE8 (F3) WH-SDF12C9E8 WH-UD12CE8 (F3) WH-SDF14C9E8 WH-UD14CE8 (F3) WH-SDF16C9E8 WH-UD16CE8 (F3) WH-SDC09C3E8 WH-UD09CE8 (F3) WH-SDC12C9E8 WH-UD12CE8 (F3) WH-SDC14C9E8 WH-UD14CE8 (F3) WH-SDC16C9E8 WH-UD16CE8 (F3) WH-MDF12C6E5 (F4) WH-MDF14C6E5 (F4) WH-MDF16C6E5 (F4) WH-MDC09C3E5 (F4) NEW WH-MDC09E3E5** (F5) 2012 WH-MDC12C6E5 (F4) WH-MDC14C6E5 (F4) WH-MDC16C6E5 (F4) WH-MDF09C3E8 (F4) WH-MDF12C9E8 (F4) WH-MDF14C9E8 (F4) WH-MDF16C9E8 (F4) WH-MDC09C3E8 (F4) WH-MDC12C9E8 (F4) WH-MDC14C9E8 (F4) WH-MDC16C9E8 (F4) WH-MDF09C3E5 (F4) WH-MDF09D3E5 (F5) WH-SXF09D3E5 WH-UX09DE5 (F2) NEW WH-SXF12D6E5 WH-UX12DE5 (F3) NEW WH-SXC09D3E5 WH-UX09DE5 (F2) WH-SXC12D6E5 WH-UX12DE5 (F3) N W NEW WH-SXF09D3E8 WH-UX09DE8 (F3) WH-SXF12D9E8 WH-UX12DE8 (F3) NEW WH-SXC12D9E8 WH-UX12DE8 (F3) N W NEW 2012 NEW 2012 N W NEW 2012 WH-MXF09D3E5 (F4) NEW 2012 2012 WH-MXF12D6E5 (F4)4) NEW N W NEW 2012 WH-MXC12D6E5 (F4)4) NEW N W NEW 2012 WH-MXF12D9E8 (F4)4) NEW 2012 WH-MXC09D3E8 (F4) NEW 2012 WH-MXC12D9E8 (F4)4) 2012 WH-SHF09D3E5 WH-UH09DE5 (F3) N W NEW 2012 WH-SHF09D3E8 WH-UH09DE8 (F3) N W NEW 2012 WH-MHF09D3E5 (F4) WH-MHF09D3E8 (F4) 71 kW 2012 2012 WH-MXF09D3E8 (F4) 50KW 2012 2012 WH-MXC09D3E5 (F4) 28KW 2012 NEW WH-SXC09D3E8 WH-UX09DE8 (F3) FIGURE 7 (F7) NEW 2012 WH-SHF12D6E5 WH-UH12DE5 (F3) N W NEW 2012 WH-SHF12D9E8 WH-UH12DE8 (F3) N W NEW 2012 WH-MHF12D6E5 (F4) 4) WH-MHF12D9E8 (F4) 4) NEW 2012 NEW 2012 NEW 2012 NEW 2012 S-250WX2E5 (F6) NEW S-500WX2E5 (F6) 2012 S-250WX2E5 (F6) NEW 2012 NEW 2012 S-500WX2E5 (F6) NEW 2012 S-710WX2E5 (F7) NEW 2012 ** Avaiable in November 2012 33 4.62 COP high efficiency AQUAREA HIGH CONNECTIVITY HIGH H CON CON CO NNECT CTIVIT CTIVIT IVITY Y AQUA AQUA QUAREA REA RE EA A efficiency high 4.62 COP BI-BLOC // HIGH CONNECTIVITY // 3 AND 5 KW AQUAREA // HEATING ONLY - SDF // HEATING AND COOLING - SDC The new 3 kW and 5 kW Aquarea heat pump from Panasonic is specially design specially designed for low energy homes. Thanks to the system's high degree of technology and advanced control, they are able to maintain a high capacity and efficiency event at -7°C and -15°C. The very compact outdoor unit makes the installation very easy. Whatever the weather, Aquarea will always give you maximum efficiency, even at -20 ºC. NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in heating mode 5 year compressor warranty OUTDOOR TEMPERATURE OPTIONAL BI-BLOC // MINI T-CAP // HEATING ONLY // HEATING AND COOLING // SDC INDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35°C Cooling capacity at 35°C EER at 35°C with cooling water temperature at 7/12°C Dimensions (H x W x D) Weight Water pipe connector Pump kW kW kW mm kg No. of Speed Input Power(max) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Liquid Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) SINGLE-PHASE HEATING AND COOLING WH-SDC03D3E5* WH-SDC05D3E5* 3 4,62 3 2,7 - 5 4,5 5 2,8 4,5 2,90 892 x 502 x 353 50 5 4,5 4,2 2,5 - - 892 x 502 x 353 50 892 x 502 x 353 50 3 4,62 3 2,7 3 2,97 892 x 502 x 353 50 WH-UD03EE5 47 WH-UD05EE5 WH-UD03EE5 WH-UD05EE5 48 47 48 618 x 833 x 301 38 12,70 (1/2") 6,35 (1/4") 618 x 833 x 301 38 12,70 (1/2") 6,35 (1/4") 618 x 833 x 301 38 12,70 (1/2") 6,35 (1/4") 618 x 833 x 301 38 12,70 (1/2") 6,35 (1/4") 5 – 15 5 – 15 5 – 15 5 – 15 5 –20 to 35 25 – 55 / 5 – 20 5 –20 to 35 25 – 55 / 5 – 20 5 –20 to 35 25 – 55 / 5 – 20 5 –20 to 35 25 – 55 / 5 – 20 W l/min kW kW Running and starting Current Maximum Current OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter SINGLE-PHASE HEATING ONLY WH-SDF03D3E5* WH-SDF05D3E5* A A dB(A) dB mm kg mm (Inch) mm (Inch) kg m m m g/m m °C °C COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. * Available in September, Preliminary specifications TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 34 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C AQUAREA NEW 2011-2012 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · NEW! RANGE FROM 3 AND 5 KW, SINGLE-PHASE, HEATING ONLY AND HEATING AND COOLING · MAXIMUM OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · EASY AND FAST TO INSTALL ENERGY AND ENVIRONMENTAL EFFICIENCY · Super efficient even at outdoor temperatures as low as -15°C · Maximum COP of 4,62 · Environmentally-friendly refrigerant gas R410A COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Wired control panel for installation in the house · Easy programming on the control panel · Ipad/Android ready with the IntesisHome box (optional) EASY INSTALLATION AND MAINTENANCE · Outdoor unit easy to open for maintenance . Expansion vessel included WH-UD03EE5 WH-UD05EE5 WH-TD20E3E5 WH-TD30E3E5 35 4.41* COP high efficiency AQUAREA HIGH CONNECTIVITY HI HIGH CON NNECT N IVITY AQ A AQUAR AQUA QUA UAREA REA A efficiency high 4.74* COP AQUAREA MDF & MDC // MONO-BLOC // HIGH CONNECTIVITY // 6 AND 9 KW AQUAREA // HEATING AND COOLING // SINGLE-PHASE Panasonic has designed the new Aquarea Mono-bloc heat pump for houses which have high performance requirements but limited space to install the outdoor unit. Whatever the weather, Aquarea will always give you maximum efficiency, even at -20 ºC. The Mono-bloc is easy to install on new or existing installations, in all type of houses. NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in heating mode 5 year compressor warranty OUTDOOR TEMPERATURE OPTIONAL MONO-BLOC // 6 AND 9 KW AQUAREA // HEATING // MDF & MDC SINGLE-PHASE Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at +2°C COP at +2°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Cooling capacity at 35°C EER at 35°C with cooling water temperature at 7/12°C Sound pressure level Sound power level Dimensions (H x W x D) Weight Water pipe connector Pump kW kW kW kW kW dB(A) dB mm kg No. of Speed Water Flow (ΔT=5 K. 35°C) Input Power Capacity of integrated electric heater Input Power at +7°C Running and starting Current at +7°C Maximum Current Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) l/min W kW kW A A °C °C WH-MDF06D3E5 WH-MDF09D3E5 WH-MDC06E3E5* WH-MDC09E3E5* 6 4.41 5 3.4 5.15 2.65 5.9 2.2 47 65 865 x 1283 x 320 112 R 1-3/16 3 17.2 75 3.0 1.36 6.2 20.5 -20 to 35 25 – 55 9 4.10 7 3 7.45 3.10 7.6 2.0 49 67 865 x 1283 x 320 112 R 1-3/16 3 25.8 75 3.0 2.2 10.1 22.9 -20 to 35 25 – 55 6 4.41 5 3.4 5.15 2.65 5.9 2.2 5.5 2.71 47 65 865 x 1283 x 320 112 R 1-3/16 3 17.2 75 3.0 1.36 6.2 20.5 -20 to 35 25 – 55 9 4.10 7 3 7.45 3.10 7.6 2.0 7.0 2.41 49 67 865 x 1283 x 320 112 R 1-3/16 3 25.8 75 3.0 2.2 10.1 22.9 -20 to 35 25 – 55 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. * Preliminary specifications TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 36 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C AQUAREA NEW 2011-2012 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · NEW! RANGE FROM 6 AND 9 KW, SINGLE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · PLUG AND PLAY SYSTEM ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4,41 · Environmentally-friendly refrigerant gas R410A COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Single-unit range, with no refrigerant connections · Wired control panel for installation in the house · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Outdoor unit easy to open for maintenance WH-MDF06D3E5 WH-MDF09D3E5 WH-MDF06E3E5 WH-MDF09E3E5 WH-TD20E3E5 WH-TD30E3E5 37 4.74* COP high efficiency AQUAREA HIGH CONNECTIVITY HI HIGH CON NNECT N IVITY AQ A AQUAR AQUA QUA UAREA REA A efficiency high 4.74* COP AQUAREA SDF // BI-BLOC // HIGH CONNECTIVITY // HEATING ONLY SINGLE-PHASE // THREE-PHASE The Aquarea SDF range adapts equally well to an existing installation such as a boiler backup or to a new installation with underfloor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating control and management. NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high down to friendly efficiency heating -20ºC in refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET boiler connection heating mode OUTDOOR TEMPERATURE R410A domestic solar hot panels connection RETROFIT water SOLAR KIT 5 year compressor warranty DHW OPTIONAL BI-BLOC // HIGH-CONNECTIVITY // HEATING ONLY // SDF SINGLE-PHASE THREE-PHASE WH-SDF07C3E5 WH-SDF09C3E5 WH-SDF12C6E5 WH-SDF14C6E5 WH-SDF16C6E5 WH-SDF09C3E8 WH-SDF12C9E8 WH-SDF14C9E8 WH-SDF16C9E8 INDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35 °C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Running and starting Current Maximum Current kW W l/min kW kW A A 7 4,4 5,15 2,65 4,6 2,3 892 x 502 x 353 43 R1 1/4 3 100 20,1 3 1,59 7,3 21 WH-UD07CE5-A WH-UD09CE5-A WH-UD12CE5-A WH-UD14CE5-A WH-UD16CE5-A WH-UD09CE8 WH-UD12CE8 WH-UD14CE8 WH-UD16CE8 dB(A) dB mm KG mm (Inch) mm (Inch) kg m m m g/m m °C °C 48 66 795 x 900 x 320 66 6,35 (1/4") 15,88 (5/8") 1,45 3 – 30 7 10 30 20 –20 to 35 25 – 55 50 67 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 51 68 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 53 70 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,95 3 – 40 7 30 50 30 –20 to 35 25 – 55 kW kW mm kg OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter Liquid Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) 9 4,10 5,9 2,5 5,9 2,2 892 x 502 x 353 43 R1 1/4 3 100 25,8 3 2,2 10,1 22,9 49 67 795 x 900 x 320 66 6,35 (1/4") 15,88 (5/8") 1,45 3 – 30 7 10 30 20 –20 to 35 25 – 55 12 4,67 10 2,7 8,9 2,43 892 x 502 x 353 49 R1 1/4 3 190 34,4 6 2,57 11,7 24 50 67 1340 x 900 x 320 106 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 14 4,5 10,7 2,62 9,5 2,35 892 x 502 x 353 49 R1 1/4 3 190 40,1 6 3,11 14,1 25 51 68 1340 x 900 x 320 106 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 16 4,23 11,4 2,55 10,3 2,33 892 x 502 x 353 49 R1 1/4 3 190 45,9 6 3,78 17,1 26 53 70 1340 x 900 x 320 106 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 9 4,74 9 2,81 8,3 2,55 892 x 502 x 353 50 R1 1/4 3 190 25,8 3 1,9 2,9 7,5 12 4,67 10 2,7 8,9 2,43 892 x 502 x 353 51 R1 1/4 3 190 34,4 9 2,57 3,9 8,8 14 4,5 10,7 2,62 9,5 2,35 892 x 502 x 353 51 R1 1/4 3 190 40,1 9 3,11 4,7 9,4 16 4,23 11,4 2,55 10,3 2,33 892 x 502 x 353 51 R1 1/4 3 190 45,9 9 3,78 5,7 9,9 49 66 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 38 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C AQUAREA TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 7 TO 16 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · MAXIMUM 40 m RISE BETWEEN THE OUTDOOR UNIT AND THE HYDRAULIC MODULE ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 · Environmentally-friendly refrigerant gas R410A COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Control on the hydraulic module · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Easy-to-access pressure gauge for easy control of the water pressure · Easy-to-open hydraulic module and outdoor unit WH-UD07CE5-A WH-UD09CE5-A WH-UD09CE8 WH-UD12CE5-A WH-UD14CE5-A WH-UD16CE5-A WH-UD12CE8 WH-UD14CE8 WH-UD16CE8 WH-TD20E3E5 WH-TD30E3E5 39 4.74* COP high efficiency AQUAREA HIGH CONNECTIVITY HI HIGH CON NNECT N IVITY AQ A AQUAR AQUA QUA UAREA REA A efficiency high 4.74* COP AQUAREA SDC // BI-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE The Aquarea SDC range adapts equally well to an existing installation such as a boiler backup or to a new installation with underfloor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating and cooling control and management. NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high down to friendly efficiency heating -20ºC in refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET boiler connection heating mode OUTDOOR TEMPERATURE R410A RETROFIT domestic solar hot panels connection water SOLAR KIT 5 year compressor warranty DHW OPTIONAL BI-BLOC // HIGH-CONNECTIVITY // HEATING AND COOLING // SDC SINGLE-PHASE INDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Cooling capacity at 35°C EER at 35°C with cooling water temperature at 7/12°C Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power (Input power H/C) Running and starting Current Maximum Current OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter Liquid Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) WH-SDC07C3E5 kW 7 4,4 kW 5,15 2,65 kW 4,6 2,3 6 2,2 mm 892 x 502 x 353 kg 45 R1 1/4 3 W 75 l/min 20,1 kW 3 kW 1,59 / 2,30 A 7,30 / 10,40 A 21 WH-UD07CE5-A dB(A) 48 dB 66 mm 795 x 900 x 320 KG 66 mm (Inch) 6,35 (1/4") mm (Inch) 15,88 (5/8") kg 1,45 m 3 – 30 m 7 m 10 g/m 30 m 20 °C –20 to 35 °C 25 – 55 / 5 – 20 THREE-PHASE WH-SDC09C3E5 9 4,09 5,9 2,5 5,9 2,2 7 2,1 892 x 502 x 353 45 R1 1/4 3 75 25,8 3 2,2 / 2,9 10,1 / 13,1 22,9 WH-UD09CE5-A 49 67 795 x 900 x 320 66 6,35 (1/4") 15,88 (5/8") 1,45 3 – 30 7 10 30 20 –20 to 35 25 – 55 / 5 – 20 WH-SDC12C6E5 12 4,67 10 2,7 8,9 2,43 10 2,39 892 x 502 x 353 51 R1 1/4 3 190 34,4 6 2,57 / 3,6 11,7 / 16,1 24 WH-UD12CE5-A 50 67 1340 x 900 x 320 106 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 WH-SDC14C6E5 14 4,5 10,7 2,62 9,5 2,35 11,5 2,24 892 x 502 x 353 51 R1 1/4 3 190 40,1 6 3,11 / 4,4 14,1 / 19,7 25 WH-UD14CE5-A 51 68 1340 x 900 x 320 106 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 WH-SDC16C6E5 16 4,23 11,4 2,55 10,3 2,33 12,2 2,19 892 x 502 x 353 51 R1 1/4 3 190 45,9 6 3,78 / 4,8 17,1 / 21,5 26 WH-UD16CE5-A 53 70 1340 x 900 x 320 106 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 WH-SDC09C9E8 9 4,74 9 2,81 8,3 2,55 7 2,68 892 x 502 x 353 51 R1 1/4 3 190 25,8 3 1,9 / 2,25 2,9 / 3,4 7,5 WH-UD09CE8 49 66 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 WH-SDC12C9E8 12 4,67 10 2,7 8,9 2,43 10 2,42 892 x 502 x 353 52 R1 1/4 3 190 34,4 9 2,57 / 3,55 3,9 / 5,3 8,8 WH-UD12CE8 50 67 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 WH-SDC14C9E8 14 4,5 10,7 2,62 9,5 2,35 11,5 2,25 892 x 502 x 353 52 R1 1/4 3 190 40,1 9 3,11 / 4,4 4,7 / 6,6 9,4 WH-UD14CE8 51 68 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,75 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 WH-SDC16C9E8 16 4,23 11,4 2,55 10,3 2,33 12,2 2,19 892 x 502 x 353 52 R1 1/4 3 190 45,9 9 3,78 /4,8 5,7 / 7,2 9,9 WH-UD16CE8 53 70 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 2,95 3 – 40 7 30 50 30 –20 to 35 25 – 55 / 5 – 20 TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 40 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C AQUAREA TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 7 TO 16 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · MAXIMUM 40 m RISE BETWEEN THE OUTDOOR UNIT AND THE HYDRAULIC MODULE · COOLING TEMPERATURE RANGE 5–20 °C ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 · Environmentally-friendly refrigerant gas R410A COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Control on the hydraulic module · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Easy-to-access pressure gauge for easy control of the water pressure · Easy-to-open hydraulic module and outdoor unit WH-UD07CE5-A WH-UD09CE5-A WH-UD09CE8 WH-UD12CE5-A WH-UD14CE5-A WH-UD16CE5-A WH-UD12CE8 WH-UD14CE8 WH-UD16CE8 WH-TD20E3E5 WH-TD30E3E5 41 4.74* COP high efficiency AQUAREA HIGH CONNECTIVITY HI HIGH CON NNECT N IVITY AQ A AQUAR AQUA QUA UAREA REA A efficiency high 4.74* COP AQUAREA MDF // MONO-BLOC // HIGH CONNECTIVITY // HEATING ONLY SINGLE-PHASE // THREE-PHASE The Aquarea MDF range adapts equally well to an existing installation such as a boiler backup or to a new installation with underfloor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating control and management. NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT solar domestic panels connection SOLAR KIT hot water 5 year compressor warranty DHW OPTIONAL MONO-BLOC // HIGH-CONNECTIVITY // HEATING ONLY // MDF SINGLE-PHASE OUTDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35 °C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Sound pressure level Sound power level Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (^aT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) WH-MDF09C3E5 kW 9 4,74 kW 9 2,81 kW 8,3 2,55 dB(A) 49 dB 66 mm 1410 x 1283 x 320 kg 153 R1¼ 3 W 190 l/min 25,8 kW 3 kW 1,9 A 8,7 A 22,9 °C –20 to 35 °C 25 – 55 THREE-PHASE WH-MDF12C6E5 12 4,67 10 2,7 8,9 2,43 50 67 1410 x 1283 x 320 153 R1¼ 3 190 34,4 6 2,57 11,6 24 –20 to 35 25 – 55 WH-MDF14C6E5 14 4,5 10,7 2,62 9,5 2,35 51 68 1410 x 1283 x 320 153 R1¼ 3 190 40,1 6 3,11 14,1 25 –20 to 35 25 – 55 WH-MDF16C6E5 16 4,23 11,4 2,55 10,3 2,33 53 70 1410 x 1283 x 320 153 R1¼ 3 190 45,9 6 3,78 17,1 26 –20 to 35 25 – 55 WH-MDF09C3E8 9 4,74 9 2,81 8,3 2,55 49 66 1410 x 1283 x 320 157 R1¼ 3 190 25,8 3 1,9 2,9 7,5 –20 to 35 25 – 55 WH-MDF12C9E8 12 4,67 10 2,7 8,9 2,43 50 67 1410 x 1283 x 320 157 R1¼ 3 190 34,4 9 2,57 3,9 8,8 –20 to 35 25 – 55 WH-MDF14C9E8 14 4,5 10,7 2,62 9,5 2,35 51 68 1410 x 1283 x 320 157 R1¼ 3 190 40,1 9 3,11 4,7 9,4 –20 to 35 25 – 55 WH-MDF16C9E8 16 4,23 11,4 2,55 10,3 2,33 53 70 1410 x 1283 x 320 157 R1¼ 3 190 45,9 9 3,78 5,7 9,9 –20 to 35 25 – 55 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. * Tentative specifications Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 42 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C AQUAREA TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 16 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised according to the return water temperature · Autonomous management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Single-unit range, with no refrigerant connections · Wired control panel for installation in the house · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Outdoor unit easy to open for maintenance WH-TD20E3E5 WH-TD30E3E5 43 4.74* COP high efficiency AQUAREA HIGH CONNECTIVITY HI HIGH CON NNECT N IVITY AQ A AQUAR AQUA QUA UAREA REA A efficiency high 4.74* COP AQUAREA MDC // MONO-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE The Aquarea MDC range adapts equally well to an existing installation such as a boiler backup or to a new installation with floor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating and cooling control and management. NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT solar domestic panels connection SOLAR KIT hot water 5 year compressor warranty DHW OPTIONAL MONO-BLOC // HIGH-CONNECTIVITY // HEATING AND COOLING // MDC SINGLE-PHASE OUTDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Cooling capacity at 35°C EER at 35°C with cooling water temperature at 7/12°C Sound pressure level Sound power level Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (^aT=5 K. 35°C) Capacity of integrated electric heater Input Power (Input Power H/C) Starting Current (Input Power H/C) Maximum Current Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW kW kW kW dB(A) dB mm kg W l/min kW kW A A °C °C WH-MDC09C3E5 9 4,74 9 2,81 8,3 2,55 7 2,68 49 66 1410 x 1283 x 320 153 R1¼ 3 190 25,8 3 1,9 / 2,25 8,7 / 10,2 22,9 –20 to 35 22 - 55 / 5 - 20 THREE-PHASE WH-MDC12C6E5 12 4,67 10 2,7 8,9 2,43 10 2,39 50 67 1410 x 1283 x 320 153 R1¼ 3 190 34,4 6 2,57 / 3,6 11,6 / 16,1 24 –20 to 35 22 - 55 / 5 - 20 WH-MDC14C6E5 14 4,5 10,7 2,62 9,5 2,35 11,5 2,25 51 68 1410 x 1283 x 320 153 R1¼ 3 190 40,1 6 3,11 / 4,4 14,1 / 19,7 25 –20 to 35 22 - 55 / 5 - 20 WH-MDC16C6E5 16 4,23 11,4 2,55 10,3 2,33 12,2 2,19 53 70 1410 x 1283 x 320 153 R1¼ 3 190 45,9 6 3,78 / 4,8 17,1 / 21,5 26 –20 to 35 22 - 55 / 5 - 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 44 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES WH-MDC09C3E8 9 4,74 9 2,81 8,3 2,55 7 2,68 49 66 1410 x 1283 x 320 157 R1¼ 3 190 25,8 3 1,9 / 2,25 2,9 / 3,4 7,5 –20 to 35 22 - 55 / 5 - 20 WH-MDC12C9E8 12 4,67 10 2,7 8,9 2,43 10 2,39 50 67 1410 x 1283 x 320 157 R1¼ 3 190 34,4 9 2,57 / 3,6 3,9 / 5,3 8,8 –20 to 35 22 - 55 / 5 - 20 WH-MDC14C9E8 14 4,5 10,7 2,62 9,5 2,35 11,5 2,25 51 68 1410 x 1283 x 320 157 R1¼ 3 190 40,1 9 3,11 / 4,4 4,7 / 6,6 9,4 –20 to 35 22 - 55 / 5 - 20 WH-MDC16C9E8 16 4,23 11,4 2,55 10,3 2,33 12,2 2,19 53 70 1410 x 1283 x 320 157 R1¼ 3 190 45,9 9 3,78 / 4,8 5,7 / 7,2 9,9 –20 to 35 22 - 55 / 5 - 20 AQUAREA TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 16 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · COOLING TEMPERATURE RANGE 5–20 °C ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised according to the return water temperature · Autonomous management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Single-unit range, with no refrigerant connections · Wired control panel for installation in the house · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Outdoor unit easy to open for maintenance WH-TD20E3E5 WH-TD30E3E5 45 100% capacity at -15°C AQUAREA T-CAP AQUA QUAREA T T-CA CAP CA at -15°C capacity 100% NEW iPHONE & ANDROID READY AQUAREA SXF // BI-BLOC // T-CAP // HEATING ONLY SINGLE-PHASE // THREE-PHASE The Aquarea SXF is the new Aquarea product from Panasonic for central heating. T-CAP stands for Total capacity as this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water temperature. The new SXF is ideal for houses where maintaining the same capacity is important such as new houses or houses without support from an external boiler. The SXF can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating, low-temperature radiators or even fan-coil heaters. This Range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating control and management. CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT solar panels connection SOLAR KIT domestic hot water 5 year compressor warranty DHW OPTIONAL BI-BLOC // AQUAREA T-CAP // HEATING ONLY // SXF SINGLE-PHASE INDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35 °C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter Liquid Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW kW kW mm kg W l/min kW kW A A dB(A) dB mm KG mm (Inch) mm (Inch) kg m m m g/m m °C °C WH-SXF09D3E5 9 4,74 9 2,81 9 2,54 892 x 502 x 353 47 R1¼ 3 190 25,8 3 1,9 8,8 25 WH-UX09DE5 49 66 1340 x 900 x 320 107 9,52 (3/8") 15,88 (5/8") 3,10 3 – 30 7 15 50 20 –20 to 35 25 – 55 THREE-PHASE WH-SXF12D6E5 12 4,67 12 2,7 12 2,4 892 x 502 x 353 49 R1¼ 3 190 34,4 3 2,57 11,9 29 WH-UX12DE5 49 66 1340 x 900 x 320 107 9,52 (3/8") 15,88 (5/8") 3,10 3 – 30 7 15 50 20 –20 to 35 25 – 55 WH-SXF09D3E8 9 4,74 9 2,81 9 2,54 892 x 502 x 353 50 R1¼ 3 190 25,8 3 1,9 2,9 10,4 WH-UX09DE8 49 66 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 3,10 3 – 30 7 15 50 20 –20 to 35 25 – 55 WH-SXF12D9E8 12 4,67 12 2,7 12 2,4 892 x 502 x 353 51 R1¼ 3 190 34,4 9 2,57 3,9 11,9 WH-UX12DE8 49 66 1340 x 900 x 320 109 9,52 (3/8") 15,88 (5/8") 3,10 3 – 30 7 15 50 20 –20 to 35 25 – 55 WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 46 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES AQUAREA NEW 2011 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · MAXIMUM 30 m RISE BETWEEN THE OUTDOOR UNIT AND THE HYDRAULIC MODULE · CONSTANT CAPACITY AT OUTDOOR TEMPERATURES DOWN TO -15 °C (AT A HEATING WATER TEMPERATURE OF 35 °C) ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 · Environmentally-friendly refrigerant gas R410A COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Control on the hydraulic module · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Easy-to-access pressure gauge for easy control of the water pressure · Easy-to-open hydraulic module and outdoor unit WH-UX09DE5 WH-UX12DE5 WH-UX09DE8 WH-UX12DE8 WH-TD20E3E5 WH-TD30E3E5 47 100% capacity at -15°C AQUAREA T-CAP AQUA QUAREA T T-CA CAP CA at -15°C capacity 100% NEW iPHONE & ANDROID READY AQUAREA SXC // BI-BLOC // T-CAP // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE The Aquarea SXC is the new Aquarea product from Panasonic for heating and cooling. T-CAP stands for Total capacity as this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water temperature. The new SXC is ideal for houses where maintaining the same capacity is important such as new houses or houses without support from an external boiler. The SXC can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management. CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT solar panels connection SOLAR KIT domestic hot water 5 year compressor warranty DHW OPTIONAL BI-BLOC // AQUAREA T-CAP // HEATING AND COOLING // SXC SINGLE-PHASE INDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Cooling capacity at 35°C EER at 35°C with cooling water temperature at 7/12°C Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter Liquid Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW kW kW mm kg W l/min kW kW A A dB(A) dB mm kg mm (Inch) mm (Inch) kg m m m g/m m °C °C WH-SXC09D3E5 9 4,74 9 2,81 9 2,54 7 3,11 892 x 502 x 353 48 R1¼ 3 180 25,8 3 1,9 10,4 25 WH-UX09DE5 49 66 1340 x 900 x 320 107 9,52 (3/8") 15,88 (5/8") 3,10 3 – 30 7 15 50 20 –20 to 35 25 – 55 THREE-PHASE WH-SXC12D6E5 12 4,67 12 2,7 12 2,4 10 2,78 892 x 502 x 353 51 R1¼ 3 180 34,4 6 2,57 16,7 29 WH-UX12DE5 50 67 1340 x 900 x 320 107 9,52 (3/8") 15,88 (5/8") 2,75 3 – 30 7 15 50 20 –20 to 35 25 – 55 WH-SXC09D3E8 9 4,74 9 2,81 9 2,54 7 3,11 892 x 502 x 353 51 R1¼ 3 180 25,8 3 1,9 3,5 10,4 WH-UX09DE8 49 66 1340 x 900 x 320 110 9,52 (3/8") 15,88 (5/8") 2,75 3 – 30 7 15 50 20 –20 to 35 25 – 55 WH-SXC12D9E8 12 4,67 12 2,7 12 2,4 10 2,78 892 x 502 x 353 52 R1¼ 3 180 34,4 9 2,57 5,6 11,9 WH-UX12DE8 50 67 1340 x 900 x 320 110 9,52 (3/8") 15,88 (5/8") 2,75 3 – 30 7 15 50 20 –20 to 35 25 – 55 WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 48 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES AQUAREA NEW 2011 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · MAXIMUM 20 m RISE BETWEEN THE OUTDOOR UNIT AND THE HYDRAULIC MODULE · CONSTANT CAPACITY AT OUTDOOR TEMPERATURES DOWN TO -15 °C (AT A HEATING WATER TEMPERATURE OF 35 °C) · COOLING TEMPERATURE RANGE 5–20 °C WH-UX09DE5 WH-UX12DE5 WH-UX09DE8 WH-UX12DE8 ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 · Environmentally-friendly refrigerant gas R410A COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Control on the hydraulic module · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Easy-to-access pressure gauge for easy control of the water pressure · Easy-to-open hydraulic module and outdoor unit WH-TD20E3E5 WH-TD30E3E5 49 100% capacity at -15°C AQUAREA T-CAP AQUA QUAREA T T-CA CAP CA at -15°C capacity 100% NEW iPHONE & ANDROID AQUAREA MXF // MONO-BLOC // T-CAP // HEATING ONLY SINGLE-PHASE // THREE-PHASE The Aquarea MXF is the new Aquarea product from Panasonic for central heating. T-CAP stands for Total capacity as this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water temperature. The new MXF is ideal for houses where maintaining the same capacity is important such as new houses or houses without support from an external boiler. The MXF can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating control and management. READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET down to -20ºC in connection heating mode OUTDOOR TEMPERATURE R410A boiler solar panels connection RETROFIT SOLAR KIT domestic hot water 5 year compressor warranty DHW OPTIONAL MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MXF SINGLE-PHASE OUTDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35 °C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Sound pressure level Sound power level Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (^aT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW kW kW dB(A) dB mm kg W l/min kW kW A A °C °C WH-MXF09D3E5 9 4,74 9 2,81 9 2,54 49 66 1410 x 1283 x 320 155 R1¼ 3 190 25,8 3 1,9 8,8 25 –20 to 35 25 – 55 THREE-PHASE WH-MXF12D6E5 12 4,67 12 2,7 12 2,4 50 67 1410 x 1283 x 320 155 R1¼ 3 190 34,4 6 2,57 11,9 29 –20 to 35 25 – 55 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 50 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES WH-MXF09D3E8 9 4,74 9 2,81 9 2,54 49 66 1410 x 1283 x 320 158 R1¼ 3 190 25,8 3 1,9 2,9 10,4 –20 to 35 25 – 55 WH-MXF12D9E8 12 4,67 12 2,7 12 2,4 50 67 1410 x 1283 x 320 158 R1¼ 3 190 34,4 9 2,57 3,9 11,9 –20 to 35 25 – 55 AQUAREA NEW 2012 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised according to the return water temperature · Autonomous management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Single-unit range, with no refrigerant connections · Wired control panel for installation in the house · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Outdoor unit easy to open for maintenance WH-TD20E3E5 WH-TD30E3E5 51 100% capacity at -15°C AQUAREA T-CAP AQUA QUAREA T T-CA CAP CA at -15°C capacity 100% NEW iPHONE & ANDROID AQUAREA MXC // MONO-BLOC // T-CAP // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE The Aquarea MXC is the new Aquarea product from Panasonic for heating and cooling. T-CAP stands for Total capacity as this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water temperature. The new MXC is ideal for houses where maintaining the same capacity is important such as new houses or houses without support from an external boiler. The MXC can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating, low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management. READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R410A down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT solar panels connection SOLAR KIT domestic hot water 5 year compressor warranty DHW OPTIONAL MONO-BLOC // AQUAREA T-CAP // HEATING AND COOLING// MXC SINGLE-PHASE OUTDOOR UNIT Heating Capacity at +7°C COP at +7°C with heating water temperature at 35°C Heating Capacity at -7°C COP at -7°C with heating water temperature at 35°C Heating Capacity at -15°C COP at -15°C with heating water temperature at 35°C Cooling capacity at 35°C EER at 35°C with cooling water temperature at 7/12°C Sound pressure level Sound power level Dimensions (H x W x D) Weight Water pipe connector Pump No. of Speed Input power(max) Heating water flow (^aT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW kW kW kW dB(A) dB mm kg W l/min kW kW A A °C °C WH-MXC09D3E5 9 4,74 9 2,81 9 2,54 7 3,11 49 66 1410 x 1283 x 320 155 R1¼ 3 190 25,8 3 1,9 10,4 25 –20 to 35 22 - 55 / 5 - 20 THREE-PHASE WH-MXC12D6E5 12 4,67 12 2,7 12 2,4 10 2,78 50 67 1410 x 1283 x 320 155 R1¼ 3 190 34,4 6 2,57 16,7 29 –20 to 35 22 - 55 / 5 - 20 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 52 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES WH-MXC09D3E8 9 4,74 9 2,81 9 2,54 7 3,11 49 66 1410 x 1283 x 320 158 R1¼ 3 190 25,8 3 1,9 2,9 10,4 –20 to 35 22 - 55 / 5 - 20 WH-MXC12D9E8 12 4,67 12 2,7 12 2,4 10 2,78 50 67 1410 x 1283 x 320 158 R1¼ 3 190 34,4 9 2,57 3,9 11,9 –20 to 35 22 - 55 / 5 - 20 AQUAREA NEW 2012 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C · WORKS DOWN TO –20 °C · COOLING TEMPERATURE RANGE 5–20 °C ENERGY AND ENVIRONMENTAL EFFICIENCY · 78% more efficient than an electrical convection system · Maximum COP of 4.74 for the 9 kW model COMFORT · Optimum control possible with a room temperature thermostat (not supplied) · Maximum hydraulic module output temperature: 55 °C · Power optimised according to the return water temperature · Autonomous management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Single-unit range, with no refrigerant connections · Wired control panel for installation in the house · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Outdoor unit easy to open for maintenance WH-TD20E3E5 WH-TD30E3E5 53 AQUAREA SHF // BI-BLOC // HT // HEATING ONLY SINGLE-PHASE // THREE-PHASE output water 65ºC For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution is probably the most adequate as Aquarea HT provides output water temperatures of 65°C even at -15°C. Aquarea HT is able to deliver 65°C with the Heat Pump alone. HIGH TEMP HEAT PUMP H HEAT PU UMP HIGH TEMP HIGH TEM MP 65ºC water output NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R407C down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT domestic solar hot panels connection water SOLAR KIT 5 year compressor warranty DHW OPTIONAL BI-BLOC // AQUAREA HT // HEATING ONLY // SHF SINGLE-PHASE INDOOR UNIT Heating Capacity at +7°C COP at +7°C Heating Capacity at -7°C COP at -7°C Heating Capacity at -15°C COP at -15°C Heating Capacity at +7°C COP at +7°C Heating Capacity at -7°C COP at -7°C Heating Capacity at -15°C COP at -15°C Dimensions (H x W x D) Weight Water pipe connector Pump kW With heating water temperature at 35°C kW kW kW With heating water temperature at 65°C No. of Speed Input power(max) Heating water flow (ΔT=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter Liquid Gas Refrigerant (R407C) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R407C) I/D&O/D Hight Difference Operation Outdoor Ambient Range Water Outlet (at-2/-7/-15) 2) kW kW mm kg W l/min kW kW A A dB(A) dB mm kg mm (Inch) mm (Inch) kg m m m g/m m °C °C THREE-PHASE WH-SHF09D3E5* 9 4,55 9 2,7 9 2,4 9 2,25 8,9 1,64 7,8 1,32 892 x 502 x 353 WH-SHF12D6E5* 12 4,4 12 2,5 12 2,15 12 2,2 9,6 1,61 8 1,3 892 x 502 x 353 WH-SHF09D3E8* 9 4,55 9 2,7 9 2,4 9 2,25 8,9 1,64 7,8 1,32 892 x 502 x 353 WH-SHF12D9E8* 12 4,4 12 2,5 12 2,15 12 2,2 9,6 1,61 8 1,3 892 x 502 x 353 3 6 3 9 WH-UH09DE5 49 66 1340 x 900 x 320 WH-UH12DE5 50 67 1340 x 900 x 320 WH-UH09DE8 49 66 1340 x 900 x 320 WH-UH12DE8 50 67 1340 x 900 x 320 9,52 (3/8") 15,88 (5/8") 2,95 3 – 30 7 15 70 20 –20 to 35 25 – 65 9,52 (3/8") 15,88 (5/8") 2,95 3 – 30 7 15 70 20 –20 to 35 25 – 65 9,52 (3/8") 15,88 (5/8") 2,95 3 – 30 7 15 70 20 –20 to 35 25 – 65 9,52 (3/8") 15,88 (5/8") 2,95 3 – 30 7 15 70 20 –20 to 35 25 – 65 WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES * Tentative specifications. TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 54 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C AQUAREA NEW 2012 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 65 °C · WORKS DOWN TO –20 °C · MAXIMUM 30 M RISE BETWEEN THE OUTDOOR UNIT AND THE HYDRAULIC MODULE ENERGY AND ENVIRONMENTAL EFFICIENCY · Maximum COP of 4.55 · Environmentally-friendly refrigerant gas R407C COMFORT · Maximum hydraulic module output temperature: 65 °C · Optimum control possible with an outside thermometer (not supplied) · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Control on the hydraulic module · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Easy-to-access pressure gauge for easy control of the water pressure · Easy-to-open hydraulic module and outdoor unit WH-UH09DE5 WH-UH12DE5 WH-UH09DE8 WH-UH12DE8 WH-TD20E3E5 WH-TD30E3E5 55 AQUAREA MHF // MONO-BLOC // HT // HEATING ONLY SINGLE-PHASE // THREE-PHASE output water 65ºC For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution is probably the most adequate as Aquarea HT provides output water temperatures of 65°C even at -15°C. Aquarea HT is able to deliver 65°C with the Heat Pump alone. HIGH TEMP HEAT PUMP H HEAT PU UMP HIGH TEMP HIGH TEM MP 65ºC water output NEW iPHONE & ANDROID READY CONTROL YOUR HEAT PUMP WITH THE environmentally high friendly efficiency heating refrigerant SMART DEVICE VIA SMARTPHONES & INTERNET R407C down to -20ºC in boiler connection heating mode OUTDOOR TEMPERATURE RETROFIT domestic solar hot panels connection water SOLAR KIT 5 year compressor warranty DHW OPTIONAL MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MHF SINGLE-PHASE INDOOR UNIT Heating Capacity at +7°C COP at +7°C Heating Capacity at -7°C COP at -7°C Heating Capacity at -15°C COP at -15°C Heating Capacity at +7°C COP at +7°C Heating Capacity at -7°C COP at -7°C Heating Capacity at -15°C COP at -15°C Sound pressure level Sound power level Dimensions (H x W x D) Weight Water pipe connector Pump kW kW With heating water temperature at 35°C kW kW kW With heating water temperature at 65°C No. of Speed Input Power(max) Heating water flow (T=5 K. 35°C) Capacity of integrated electric heater Input Power Running and starting Current Maximum Current Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW dB(A) dB mm kg W l/min kW kW A A °C °C THREE-PHASE WH-MHF09D3E5* 9 4,55 9 2,7 9 2,4 9 2,25 8,9 1,64 7,8 1,32 49 66 1410 x 1283 x 320 WH-MHF12D6E5* 12 4,4 12 2,5 12 2,15 12 2,2 9,6 1,61 8 1,3 50 67 1410 x 1283 x 320 WH-MHF09D3E8* 9 4,55 9 2,7 9 2,4 9 2,25 8,9 1,64 7,8 1,32 49 66 1410 x 1283 x 320 WH-MHF12D9E8* 12 4,4 12 2,5 12 2,15 12 2,2 9,6 1,61 8 1,3 50 67 1410 x 1283 x 320 3 6 3 9 -20 to 35 25 – 65 -20 to 35 25 – 65 -20 to 35 25 – 65 -20 to 35 25 – 65 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C TANKS (MORE TANK ON THE ACCESSORIES PART) OPTIONAL STANDARD SANITARY TANK Water volume Max. water temperature Dimension Hight / Diameter Weight Power supply Material inside tank Exchange surface Energy loss at 65°C (insulated tested under EN12897) 3 Way valve included 56 L °C mm kg m2 kWh/24h WH-TD20E3E5 200 85 1230 / 580 42 230V Inox 1,4 1,7 YES WH-TD30E3E5 300 85 1700 / 580 54 230V Inox 1,8 2 YES AQUAREA NEW 2012 TECHNICAL FOCUS · NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME® DEVICE · RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE · MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 65 °C · WORKS DOWN TO –20 °C ENERGY AND ENVIRONMENTAL EFFICIENCY · Maximum COP of 4.55 · Environmentally-friendly refrigerant gas R407C COMFORT · Maximum hydraulic module output temperature: 65 °C · Optimum control possible with an outside thermometer (not supplied) · Power optimised based on the return water temperature · Built-in management of the hot water cylinder and heating EASY TO USE · NEW! Optional Smartphone control with IntensisHome® device · Easy programming on the control panel EASY INSTALLATION AND MAINTENANCE · Easy-to-access pressure gauge for easy control of the water pressure · Easy-to-open outdoor unit WH-TD20E3E5 WH-TD30E3E5 57 AQUAREA PRO THE NEW PANASONIC SOLUTION FOR CHILLED AND HOT WATER PRODUCTION! FROM 28 kW to 80 kW 58 AQUAREA NEW 2012 KEY BENEFITS: - No cascade installation up to 80 kW with GHP outdoor unit and 51,3 kW with ECOi - No Glycol needed when WHE is located on the heated part of the building - Full line-up of outdoor units which can cover up to 80 kW heat demand - Large choice-remote controls and interfaces - 3.25 COP with water at 45°C and outdoor temperature of +7°C With ECOi outdoor units: With GHP outdoor units: · Maximum hot water outlet temperature: 45 °C · Minimum chilled water outlet temperature: 7 °C · Outdoor temperature range in cooling mode: +5 °C to +43 °C · Outdoor temperature range in heating mode: -20 °C to +15 °C · Hot water outlet temperatures from 35 °C to 55 °C · Chilled water outlet temperatures from 5 °C to 15 °C · Outdoor temperature range in cooling mode: -10 °C to +43 °C · Minimum outdoor temperature in heating mode: -21 °C ECOi Water Heat Exchanger ECO G Water Heat Exchanger Electrical VRF with water heat exchanger · With this easy to install Aquarea Pro system, you can now cover projects up to 51 kW hot water demand or 44 kW on chilled application on a efficient way and cost effective. Mixed System Application · Combined with a water heat exchanger unit, the Panasonic GHP can create a flexible system--the ideal replacement for existing chiller and boiler systems. · The GHP Multi System can have an indoor unit plus a GHP chiller. When the two systems are operated independently, an outdoor unit with 130% capacity can be connected. SYSTEM EXAMPLE SYSTEM EXAMPLE Floor Heating Floor Heating Fan Coil Unit ECO G Chiller Water Heat Exchanger Buffer Tank Fan Coil Unit ECOi Chiller Water Heat Exchanger Buffer Tank Duct* Refrigerant piping Duct* Refrigerant piping Outdoor unit Water Piping Water Piping Air Handling Unit Outdoor unit Air Handling Unit * Standard DX type indoor unit system control wiring * Standard DX type indoor unit system Note: The mode of running of outdoor unit depends on the water heat exchanger’s mode. The water pump is not included in the water heat exchanger unit. For simultaneous operation, however, the maximum capacity is 130%. Please inquire details of this system design of Panasonic. Note: The mode of running of outdoor unit depends on the water heat exchanger’s mode. The water pump is not included in the water heat exchanger unit. For simultaneous operation, however, the maximum capacity is 130%. Please inquire details of this system design of Panasonic. 59 high efficiency heating AQUAREA PRO // NEW ECOi 2-WAY 6 SERIES WITH WATER HEAT EXCHANGER DESIGNED FOR CHILLED AND HOT WATER PRODUCTION With this easy to install Aquarea Pro system, you can now cover projects up to 51 kW hot water demand or 44 kW on chilled application on a efficient way and cost effective. heating efficiency f high g environmentally friendly refrigerant R410A down to -20ºC in heating mode 5 year compressor warranty OUTDOOR TEMPERATURE AQUAREA PRO // GAS VRF ECOi + WATER HEAT EXCHANGER Water heat exchanger Nominal Heating Capacity kW kW Nomimal Cooling Capacity Heating Capacity at +7°C, heating water temperature at 35°C kW COP at +7°C with heating water temperature at 35°C Heating Capacity at +7°C, heating water temperature at 45°C kW COP at +7°C with heating water temperature at 45°C Heating Capacity at -7°C, heating water temperature at 35°C kW COP at -7°C, heating water temperature at 35°C Heating Capacity at -15°C, heating water temperature at 35°C COP at -15°C with heating water temperature at 35°C kW Heating capacity at +32°C, outlet tp 6°C, inlet tp 12°C kW COP at +32°C, outlet tp 6°C, inlet tp 12°C Heating capacity at +35°C, outlet tp 7°C, inlet tp 12°C kW COP at +32°C, outlet tp 6°C, inlet tp 12°C Dimensions (H x W x D) mm Weight kg Water pipe connector Pump No. of Speed Input Power(max) W Heating water flow (∆T=5 K. 35°C) l/min Capacity of integrated electric heater kW Input Power kW Starting Current A Maximum Current A Outdoor unit Sound pressure level dB(A) Sound power level dB Dimensions (H x W x D) mm Weight kg Pipe Diameter Liquid mm (Inch) Gas mm (Inch) Refrigerant (R410A) kg Pipe Length Range m Pipe Length for nominal capacity m Pipe Length for additional gas m Additional Gas Amount (R410A) g/m I/D&O/D Hight Difference m Operation Range Outdoor Ambient °C Water Outlet (at-2/-7/-15) 2) °C Eco-i S-250WX2E5 28 S-500WX2E5 25 51,3 50 28 25 28,0 3,25 23,4 2,52 20,7 2,34 51,3 50 51,3 3,10 44,9 2,42 39,3 2,24 1000x395x965 165 Rp2 Nut thread (50A) (Field supply) --4,3 (Not equipped) 0,01 --0,07 U-10ME1E81 59 73,5 1758x770x930 281 22,22 9,52 "6.3 (Need Additional charge at site) max. 170 7,5 0< Reffer to Manual 50 (OD above) 35 (OD below) -20 ~ 15 35 ~ 45 1000x395x965 190 Rp2 Nut thread (50A) (Field supply) --8,6 (Not equipped) 0,01 --0,07 U-20ME1E81 63 77,5 1758x1540x930 423 28,58 15,88 "9.0 (Need Additional charge at site) max. 170 7,5 0< Reffer to Manual "50 (OD above) 35 (OD below)" -20 ~ 15 35 ~ 45 In ECOi 2-way systems, the water heat exchanger can only be used as a one-to-one solution for ECOi 2-way systems. A combination with other indoor or outdoor units is not allowed. * Max. piping lengths for 100 % one-to-one combination ratio. * All values shown as tentative data. Rating conditions: Cooling: outdoor 35 °C; water outlet/inlet: 7/12 °C. Heating: outdoor 7 °C DB / 6 °C WB, water outlet/inlet: 45/40 °C 60 AQUAREA NEW 2012 OPTIONAL CONTROLLER Timer remote controller CZ-RTC2 TECHNICAL FOCUS - UP TO 51 kW ON ONLY 1 OUTDOOR UNIT - PRODUCE HOT WATER AT 45°C WITH HIGH EFFICIENCY · CHILLED WATER OUTLET TEMPERATURES FROM 5 °C TO 15 °C - LARGE LINE-UP OF REMOTE CONTROLS FROM ECOI LINE-UP - HIGH EFFICIENCY UP TO -20°C ON HEATING MODE - HIGH EFFICIENCY UP TO +5 °C ON COOLING MODE (CHILLER APPLICATION) DESCRIPTION · New water heat exchanger for GHP and ECOi 6 series, dimensions reduced by 45 % · Operation and control by wired remote control CZ-RTC2 · Energy-efficient capacity control · Stainless steel plate heat exchanger with anti-freeze protection control · Change-over between heating and cooling operation · Maximum distance between outdoor unit and water heat exchanger: 170 m · Maximum hot water outlet temperature: 45 °C · Minimum chilled water outlet temperature: 7 °C · Outdoor temperature range in cooling mode: +5 °C to +43 °C · Outdoor temperature range in heating mode: -20 °C to +15 °C 61 AQUAREA PRO // NEW GAS VRF ECO G WITH WATER HEAT EXCHANGER high efficiency heating DESIGNED CHILLED AND HOT WATER PRODUCTION NEW Aquarea Pro GHP+WHE system, based of Gas Heat Pump technology, for Hot water production and Chilled application even where electricity is not available! heating efficiency f high g environmentally friendly refrigerant down to -20ºC in heating mode OUTDOOR TEMPERATURE R410A WATER HEAT EXCHANGER Nominal Heating Capacity kW kW Nomimal Cooling Capacity Heating Capacity at +7°C, heating water temperature at 35°C kW COP at +7°C with heating water temperature at 35°C Heating Capacity at +7°C, heating water temperature at 45°C kW COP at +7°C with heating water temperature at 45°C Heating Capacity at -7°C, heating water temperature at 35°C kW COP at -7°C, heating water temperature at 35°C Heating Capacity at -15°C, heating water temperature at 35°C COP at -15°C with heating water temperature at 35°C Cooling capacity at +32°C, outlet tp 6°C, inlet tp 12°C kW EER at +32°C, outlet tp 6°C, inlet tp 12°C Cooling capacity at +35°C, outlet tp 7°C, inlet tp 12°C kW EER at +32°C, outlet tp 6°C, inlet tp 12°C Dimensions (H x W x D) mm Weight kg Water pipe connector Pump No. of Speed Input Power(max) Heating water flow (∆T=5 K. 35°C) Capacity of integrated electric heater Input Power Starting Current Maximum Current Outdoor unit OUTDOOR UNIT Sound pressure level Sound power level Dimensions (H x W x D) Weight Pipe Diameter Liquid Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) W l/min KW kW A A dB(A) dB mm kg mm (Inch) mm (Inch) kg m m m g/m m °C °C S-250WX2E5 30 25 S-500WX2E5 60 50 S-710WX2E5 80 67 30 60 1,49 59,2 0,75 59,2 0,75 80 1,34 77,4 0,76 77,4 0,76 1000x395x965 110 Rp2 Nut thread (50A) (Field supply) --4,3 (NOT EQUIPPED) 0,01 --0,07 - 1000x395x965 130 Rp2 Nut thread (50A) (Field supply) --8,6 (NOT EQUIPPED) 0,01 --0,07 U-20GE2E5 U-20GE2E5 58 83 2228x1650x1000 770 28,58 15,88 "11.5 *Need additional chatge at site" max. 170 7 0< Refer to Manual "50 (OD above) / 35 (OD below)" -21 ~ 15.5 35 ~ 55 1000x395x965 150 Rp2 Nut thread (50A) (Field supply) --12,2 (NOT EQUIPPED) 0,01 --0,07 U-30GE2E5 U-30GE2E5 63 86 2228x2026x1000 830 31,75 19,05 "11.5 *Need additional chatge at site" max. 170 7 0< Refer to Manual "50 (OD above) / 35 (OD below)" -21 ~ 15.5 35 ~ 55 COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. Not valid in case of mixed systems, combination ratio in case of mixed systems: 50 to 130 %, combination ratio in case of one-to-one-systems: 100 %. Water circulating pump. Power supply: 230 V / 1 Ph / 50 Hz; power input: 0.75 kW; external pressure head: 6 m Performance calculation in agreement with EN14511. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C 62 AQUAREA NEW 2012 OPTIONAL CONTROLLER Timer remote controller CZ-RTC2 TECHNICAL FOCUS · UP TO 80 kW ON ONLY 1 OUTDOOR UNIT, WE CAN PROVIDE A 25 OR 30HP GHP FOR THIS WHE · HOT WATER OUTLET TEMPERATURES FROM 35 °C TO 55 °C · CHILLED WATER OUTLET TEMPERATURES FROM 5 °C TO 15 °C - LARGE LINE-UP OF REMOTE CONTROLS FROM ECOI LINE-UP - HIGH EFFICIENCY UP TO -20°C ON HEATING MODE - HIGH EFFICIENCY UP TO +5 °C ON COOLING MODE (CHILLER APPLICATION) DESCRIPTION · Hot water outlet temperatures from 35 °C to 55 °C · Chilled water outlet temperatures from 5 °C to 15 °C · Operation and control by wired remote control CZ-RTC2 · Energy-efficient capacity control · Stainless steel plate heat exchanger with anti-freeze protection control · Change-over between heating and cooling operation · Maximum distance between outdoor unit and water heat exchanger: 170 m · Possibility to mix DX and water heat exchanger systems · No cooling tower necessary · Hot water outlet temperatures from 35 °C to 55 °C · Chilled water outlet temperatures from 5 °C to 15 °C · Outdoor temperature range in cooling mode: -10 °C to +43 °C · Minimum outdoor temperature in heating mode: -21 °C HOT WATER SUPPLY FUNCTION SYSTEM ADVANTAGE The engine waste heat, which is normally exhausted into the atmosphere, is recovered via the heat exchanger and effectively used as hot water, so the GHP Chiller acts as a sub system that alleviates the load on the client’s main hot water system, and therefore offers ‘free’ hot water. CAPACITY AT COOLING STANDARD POINT OUTLET TEMP 75ºC Outdoor unit kW U-16GE2E5 Hot water 16.00 U-20GE2E5 20.00 U-20GEG2E5 22.00 U-25GE2E5 25.00 Hot water piping allowable pressure GHP PANASONIC 0.7 Hot water circulation rate MPa 3.9 Hot water tube size m³/h Rp 3/4 Manometer Water tank Expansion tank Boiler Pump Valve Cold water 63 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE MONO-BLOC // 6 AND 9 KW AQUAREA // HEATING ONLY // MDF WH-MDF06D3E5 Tamb HC LWC 30 6,15 -15 5,18 -7 5,00 2 6,00 7 7,30 25 IP 30 2,52 1,70 1,25 1,15 0,80 COP 30 2,44 3,05 4,02 5,24 9,18 HC 35 5,90 5,15 5,00 6,00 7,10 IP 35 2,68 1,94 1,47 1,37 0,95 COP 35 2,20 2,65 3,40 4,38 7,47 HC 40 5,65 5,13 5,00 6,00 6,90 IP 40 2,84 2,19 1,70 1,60 1,11 COP 40 1,99 2,35 2,95 3,76 6,24 HC 45 5,40 5,10 5,00 6,00 6,70 IP 45 3,00 2,43 1,92 1,82 1,26 COP 45 1,80 2,10 2,60 3,30 5,32 HC 50 5,20 5,45 5,00 6,00 6,50 IP 50 3,17 2,83 2,21 2,11 1,43 COP 50 1,64 1,93 2,26 2,84 4,55 HC 55 5,00 5,80 5,00 6,00 6,30 IP 55 3,34 3,22 2,50 2,40 1,60 COP 55 1,50 1,80 2,00 2,50 3,94 WH-MDF09D3E5 Tamb HC LWC 30 7,90 -15 7,80 -7 7,00 2 9,00 7 9,00 25 IP 30 3,65 3,41 2,04 1,90 1,02 COP 30 2,17 2,29 3,44 4,75 8,82 HC 35 7,60 7,70 7,00 9,00 9,00 IP 35 3,80 3,66 2,33 2,20 1,34 COP 35 2,00 2,10 3,00 4,09 6,72 HC 40 7,30 7,60 7,00 9,00 9,00 IP 40 3,96 3,91 2,63 2,51 1,66 COP 40 1,85 1,94 2,67 3,59 5,42 HC 45 7,00 7,50 7,00 9,00 9,00 IP 45 4,11 4,16 2,92 2,81 1,98 COP 45 1,70 1,80 2,40 3,20 4,55 HC 50 6,45 7,55 7,00 8,95 9,00 IP 50 4,09 4,62 3,40 3,34 2,23 COP 50 1,58 1,63 2,06 2,68 4,04 HC 55 5,90 7,60 7,00 8,90 9,00 IP 55 4,06 5,08 3,88 3,87 2,48 COP 55 1,45 1,50 1,80 2,30 3,63 BI-BLOC // HIGH-CONNECTIVITY // HEATING MODE // SDF WH-SDF07C3E5 Tamb HC LWC 30 4,60 -15 5,15 -7 6,70 2 7,00 7 7,00 25 IP 30 1,87 1,80 1,83 1,43 0,79 COP 30 2,46 2,86 3,66 4,90 8,86 HC 35 4,60 5,15 6,55 7,00 7,00 IP 35 2,00 1,94 1,98 1,59 0,93 COP 35 2,30 2,65 3,31 4,40 7,53 HC 40 4,60 5,08 6,58 7,00 6,40 IP 40 2,19 2,14 2,29 1,77 1,03 COP 40 2,10 2,37 2,87 3,95 6,21 HC 45 4,60 5,00 6,60 7,00 6,10 IP 45 2,42 2,38 2,64 2,12 1,17 COP 45 1,90 2,10 2,50 3,30 5,21 HC 50 4,55 4,90 6,30 6,90 5,90 IP 50 2,68 2,47 2,90 2,30 1,33 COP 50 1,70 1,98 2,17 3,00 4,44 HC 55 4,50 4,80 6,00 6,80 5,70 IP 55 3,00 2,67 3,16 2,72 1,49 COP 55 1,50 1,80 1,90 2,50 3,83 WH-SDF09C3E5 Tamb HC LWC 30 6,00 -15 6,10 -7 6,80 2 9,00 7 9,00 25 IP 30 2,55 2,16 1,87 1,93 1,07 COP 30 2,35 2,82 3,64 4,66 8,41 HC 35 5,90 5,90 6,70 9,00 9,00 IP 35 2,68 2,36 2,16 2,20 1,27 COP 35 2,20 2,50 3,10 4,09 7,09 HC 40 5,50 5,85 6,70 9,00 8,40 IP 40 2,82 2,63 2,38 2,45 1,40 COP 40 1,95 2,22 2,82 3,67 6,00 HC 45 5,40 5,80 6,60 9,00 8,00 IP 45 3,00 2,90 2,64 2,81 1,59 COP 45 1,80 2,00 2,50 3,20 5,03 HC 50 5,20 5,80 6,30 8,95 7,80 IP 50 3,14 3,06 2,90 3,23 1,81 COP 50 1,66 1,90 2,17 2,77 4,31 HC 55 5,00 5,80 6,00 8,90 7,50 IP 55 3,33 3,22 3,16 3,87 2,03 COP 55 1,50 1,80 1,90 2,30 3,69 WH-SDF12C6E5 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,50 3,41 3,14 2,14 1,42 COP 30 2,66 3,05 3,76 5,61 8,45 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,66 3,70 3,35 2,57 1,70 COP 35 2,43 2,70 3,40 4,67 7,06 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,83 3,99 3,57 3,00 1,98 COP 40 2,22 2,41 3,08 4,00 5,96 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,99 4,28 3,78 3,43 2,27 COP 45 2,03 2,15 2,80 3,50 5,15 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,09 4,30 3,98 3,82 2,53 COP 50 1,83 2,02 2,46 3,14 4,55 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,20 4,31 4,18 4,20 2,78 COP 55 1,67 1,90 2,18 2,86 4,10 HYDRAULIC PUMP PERFORMANCE ( 09D3 // 09C3 // 12C6 // 14C6 // 16C9 ) PUMP SPEED 3 PUMP SPEED 2 PUMP SPEED 1 EXTERNAL STATIC PRESSURE (kPa) EXTERNAL STATIC PRESSURE (kPa) ( 06D3 // 07C3 ) PUMP SPEED 3 PUMP SPEED 2 PUMP SPEED 1 WATER FLOW RATE (L/min) WATER FLOW RATE (L/min) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 64 HC: Heating Capacity (kW) IP: Power Input (kW) LWC: Leaving Water Condenser Temperature (°C) Tamb: Ambient Temperature (°C) AQUAREA WH-SDF14C6E5 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,91 3,73 3,51 2,60 1,75 COP 30 2,53 2,98 3,68 5,38 8,00 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,05 4,08 3,73 3,11 2,10 COP 35 2,35 2,62 3,32 4,50 6,67 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,19 4,43 3,95 3,63 2,45 COP 40 2,15 2,30 3,01 3,86 5,71 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,33 4,78 4,17 4,14 2,80 COP 45 1,99 2,05 2,73 3,38 5,00 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,45 4,76 4,29 4,61 3,05 COP 50 1,78 1,91 2,42 2,95 4,59 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,56 4,74 4,40 5,08 3,44 COP 55 1,60 1,79 2,16 2,62 4,07 WH-SDF16C6E5 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,13 4,07 3,78 3,25 2,35 COP 30 2,57 2,92 3,57 4,92 6,81 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,42 4,47 4,00 3,78 2,73 COP 35 2,33 2,55 3,25 4,23 5,86 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,71 4,87 4,22 4,31 3,11 COP 40 2,12 2,22 2,94 3,71 5,14 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 5,00 5,26 4,44 4,84 3,49 COP 45 1,94 1,96 2,68 3,31 4,58 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,98 5,13 4,50 5,15 3,71 COP 50 1,77 1,87 2,40 2,95 4,31 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,95 4,99 4,55 5,45 3,93 COP 55 1,60 1,80 2,15 2,66 4,05 WH-SDF09C9E8 Tamb HC LWC 30 8,65 -15 9,35 -7 9,31 2 9,00 7 9,00 25 IP 30 3,10 2,95 2,39 1,58 1,09 COP 30 2,79 3,17 3,90 5,70 8,26 HC 35 8,30 9,00 9,00 9,00 9,00 IP 35 3,25 3,20 2,55 1,90 1,28 COP 35 2,55 2,81 3,53 4,74 7,03 HC 40 7,95 8,85 9,00 9,00 8,73 IP 40 3,45 3,58 2,82 2,20 1,48 COP 40 2,30 2,47 3,19 4,09 5,90 HC 45 7,60 8,70 9,00 9,00 8,46 IP 45 3,65 3,96 3,09 2,50 1,68 COP 45 2,08 2,20 2,91 3,60 5,04 HC 50 7,15 8,30 8,90 9,00 8,28 IP 50 3,75 3,93 3,53 2,80 1,86 COP 50 1,91 2,11 2,52 3,21 4,45 HC 55 6,70 7,90 8,80 9,00 8,10 IP 55 3,85 3,90 3,98 3,10 2,04 COP 55 1,74 2,03 2,21 2,90 3,97 WH-SDF12C9E8 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,50 3,41 3,14 2,14 1,42 COP 30 2,66 3,05 3,76 5,61 8,45 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,66 3,70 3,35 2,57 1,70 COP 35 2,43 2,70 3,40 4,67 7,06 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,83 3,99 3,57 3,00 1,98 COP 40 2,22 2,41 3,08 4,00 5,96 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,99 4,28 3,78 3,43 2,27 COP 45 2,03 2,15 2,80 3,50 5,15 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,09 4,30 3,98 3,82 2,53 COP 50 1,83 2,02 2,46 3,14 4,55 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,20 4,31 4,18 4,20 2,78 COP 55 1,67 1,90 2,18 2,86 4,10 WH-SDF14C9E8 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,91 3,73 3,51 2,60 1,75 COP 30 2,53 2,98 3,68 5,38 8,00 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,05 4,08 3,73 3,11 2,10 COP 35 2,35 2,62 3,32 4,50 6,67 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,19 4,43 3,95 3,63 2,45 COP 40 2,15 2,30 3,01 3,86 5,71 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,33 4,78 4,17 4,14 2,80 COP 45 1,99 2,05 2,73 3,38 5,00 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,45 4,76 4,29 4,61 3,05 COP 50 1,78 1,91 2,42 2,95 4,59 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,56 4,74 4,40 5,08 3,44 COP 55 1,60 1,79 2,16 2,62 4,07 WH-SDF16C9E8 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,13 4,07 3,78 3,25 2,35 COP 30 2,57 2,92 3,57 4,92 6,81 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,42 4,47 4,00 3,78 2,73 COP 35 2,33 2,55 3,25 4,23 5,86 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,71 4,87 4,22 4,31 3,11 COP 40 2,12 2,22 2,94 3,71 5,14 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 5,00 5,26 4,44 4,84 3,49 COP 45 1,94 1,96 2,68 3,31 4,58 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,98 5,13 4,50 5,15 3,71 COP 50 1,77 1,87 2,40 2,95 4,31 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,95 4,99 4,55 5,45 3,93 COP 55 1,60 1,80 2,15 2,66 4,05 65 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE BI-BLOC // HIGH-CONNECTIVITY // ON COOLING MODE // SDC SDC MODELS Tamb 16 25 35 43 HC 5,90 7,45 7,00 5,80 WH-SDC09 IP 1,01 1,59 2,25 2,59 COP 5,84 4,69 3,11 2,24 WH-SDC12 IP 1,30 2,30 3,55 3,95 HC 7,65 9,20 10,00 7,60 COP 5,88 4,00 2,82 1,92 WH-SDC14 IP 1,50 2,68 4,40 5,01 HC 8,85 10,00 11,50 9,05 COP 5,90 3,73 2,61 1,81 HC 9,62 10,51 12,20 10,08 WH-SDC16 IP 1,63 2,85 4,80 5,47 COP 5,90 3,69 2,54 1,84 MONO-BLOC // HIGH-CONNECTIVITY // HEATING MODE // MDF WH-MDF09C3E5 Tamb HC LWC 30 8,65 -15 9,35 -7 9,31 2 9,00 7 9,00 25 IP 30 3,10 2,95 2,39 1,58 1,09 COP 30 2,79 3,17 3,90 5,70 8,26 HC 35 8,30 9,00 9,00 9,00 9,00 IP 35 3,25 3,20 2,55 1,90 1,28 COP 35 2,55 2,81 3,53 4,74 7,03 HC 40 7,95 8,85 9,00 9,00 8,73 IP 40 3,45 3,50 2,82 2,20 1,48 COP 40 2,30 2,53 3,19 4,09 5,90 HC 45 7,60 8,70 9,00 9,00 8,46 IP 45 3,65 3,80 3,09 2,50 1,68 COP 45 2,08 2,29 2,91 3,60 5,04 HC 50 7,15 8,30 8,90 9,00 8,28 IP 50 3,75 3,85 3,53 2,80 1,86 COP 50 1,91 2,16 2,52 3,21 4,45 HC 55 6,70 7,90 8,80 9,00 8,10 IP 55 3,85 3,90 3,98 3,10 2,04 COP 55 1,74 2,03 2,21 2,90 3,97 WH-MDF12C6E5 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,50 3,41 3,14 2,14 1,42 COP 30 2,66 3,05 3,76 5,61 8,45 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,66 3,70 3,34 2,57 1,70 COP 35 2,43 2,70 3,41 4,67 7,06 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,83 3,90 3,57 3,00 1,98 COP 40 2,22 2,46 3,08 4,00 5,96 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,99 4,10 3,78 3,43 2,27 COP 45 2,03 2,24 2,80 3,50 5,15 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,09 4,20 3,98 3,82 2,53 COP 50 1,83 2,07 2,46 3,14 4,55 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,20 4,31 4,18 4,20 2,78 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MDF14C6E5 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,91 3,73 3,51 2,60 1,75 COP 30 2,53 2,98 3,68 5,38 8,00 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,05 4,00 3,73 3,11 2,10 COP 35 2,35 2,68 3,32 4,50 6,67 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,19 4,20 3,95 3,63 2,45 COP 40 2,15 2,43 3,01 3,86 5,71 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,33 4,40 4,17 4,14 2,80 COP 45 1,99 2,23 2,73 3,38 5,00 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,45 4,57 4,29 4,61 3,05 COP 50 1,78 1,99 2,42 2,95 4,59 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,56 4,74 4,40 5,08 3,44 COP 55 1,60 1,79 2,16 2,62 4,07 WH-MDF16C6E5 Tamb HC LWC 30 -15 10,60 -7 11,90 2 13,50 7 16,00 25 16,00 IP 30 4,13 4,07 3,78 3,25 2,35 COP 30 2,57 2,92 3,57 4,92 6,81 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,42 4,30 4,00 3,78 2,73 COP 35 2,33 2,65 3,25 4,23 5,86 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,71 4,50 4,22 4,31 3,11 COP 40 2,12 2,40 2,94 3,71 5,14 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 5,00 4,70 4,44 4,84 3,49 COP 45 1,94 2,19 2,68 3,31 4,58 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,98 4,85 4,50 5,15 3,71 COP 50 1,77 1,98 2,40 2,95 4,31 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,95 4,99 4,55 5,45 3,93 COP 55 1,60 1,80 2,15 2,66 4,05 HYDRAULIC PUMP PERFORMANCE EXTERNAL STATIC PRESSURE (kPa) ( 09C3 // 1266 // 14C6 // 16C6 ) PUMP SPEED 3 PUMP SPEED 2 PUMP SPEED 1 WATER FLOW RATE (L/min) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 66 HC: Heating Capacity (kW) IP: Power Input (kW) LWC: Leaving Water Condenser Temperature (°C) Tamb: Ambient Temperature (°C) AQUAREA WH-MDF09C3E8 Tamb HC LWC 30 8,65 -15 9,35 -7 9,31 2 9,00 7 9,00 25 IP 30 3,10 2,95 2,39 1,58 1,09 COP 30 2,79 3,17 3,90 5,70 8,26 HC 35 8,30 9,00 9,00 9,00 9,00 IP 35 3,25 3,20 2,55 1,90 1,28 COP 35 2,55 2,81 3,53 4,74 7,03 HC 40 7,95 8,85 9,00 9,00 8,73 IP 40 3,45 3,50 2,82 2,20 1,48 COP 40 2,30 2,53 3,19 4,09 5,90 HC 45 7,95 8,85 9,00 9,00 8,73 IP 45 3,45 3,50 2,82 2,20 1,48 COP 45 2,30 2,53 3,19 4,09 5,90 HC 50 7,15 8,30 8,90 9,00 8,28 IP 50 3,75 3,85 3,53 2,80 1,86 COP 50 1,91 2,16 2,52 3,21 4,45 HC 55 7,15 8,30 8,90 9,00 8,28 IP 55 3,75 3,85 3,53 2,80 1,86 COP 55 1,91 2,16 2,52 3,21 4,45 WH-MDF12C9E8 Tamb HC LWC 30 9,30 -15 10,40 -7 11,80 2 12,00 7 12,00 25 IP 30 3,50 3,41 3,14 2,14 1,42 COP 30 2,66 3,05 3,76 5,61 8,45 HC 35 8,90 10,00 11,40 12,00 12,00 IP 35 3,66 3,70 3,34 2,57 1,70 COP 35 2,43 2,70 3,41 4,67 7,06 HC 40 8,50 9,60 11,00 12,00 11,80 IP 40 3,83 3,90 3,57 3,00 1,98 COP 40 2,22 2,46 3,08 4,00 5,96 HC 45 8,10 9,20 10,60 12,00 11,70 IP 45 3,99 4,10 3,78 3,43 2,27 COP 45 2,03 2,24 2,80 3,50 5,15 HC 50 7,50 8,70 9,80 12,00 11,50 IP 50 4,09 4,20 3,98 3,82 2,53 COP 50 1,83 2,07 2,46 3,14 4,55 HC 55 7,00 8,20 9,10 12,00 11,40 IP 55 4,20 4,31 4,18 4,20 2,78 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MDF14C9E8 Tamb HC LWC 30 9,90 -15 11,10 -7 12,90 2 14,00 7 14,00 25 IP 30 3,91 3,73 3,51 2,60 1,75 COP 30 2,53 2,98 3,68 5,38 8,00 HC 35 9,50 10,70 12,40 14,00 14,00 IP 35 4,05 4,00 3,73 3,11 2,10 COP 35 2,35 2,68 3,32 4,50 6,67 HC 40 9,00 10,20 11,90 14,00 14,00 IP 40 4,19 4,20 3,95 3,63 2,45 COP 40 2,15 2,43 3,01 3,86 5,71 HC 45 8,60 9,80 11,40 14,00 14,00 IP 45 4,33 4,40 4,17 4,14 2,80 COP 45 1,99 2,23 2,73 3,38 5,00 HC 50 7,90 9,10 10,40 13,60 14,00 IP 50 4,45 4,57 4,29 4,61 3,05 COP 50 1,78 1,99 2,42 2,95 4,59 HC 55 7,30 8,50 9,50 13,30 14,00 IP 55 4,56 4,74 4,40 5,08 3,44 COP 55 1,60 1,79 2,16 2,62 4,07 WH-MDF16C9E8 Tamb HC LWC 30 10,60 -15 11,90 -7 13,50 2 16,00 7 16,00 25 IP 30 4,13 4,07 3,78 3,25 2,35 COP 30 2,57 2,92 3,57 4,92 6,81 HC 35 10,30 11,40 13,00 16,00 16,00 IP 35 4,42 4,30 4,00 3,78 2,73 COP 35 2,33 2,65 3,25 4,23 5,86 HC 40 10,00 10,80 12,40 16,00 16,00 IP 40 4,71 4,50 4,22 4,31 3,11 COP 40 2,12 2,40 2,94 3,71 5,14 HC 45 9,70 10,30 11,90 16,00 16,00 IP 45 5,00 4,70 4,44 4,84 3,49 COP 45 1,94 2,19 2,68 3,31 4,58 HC 50 8,80 9,60 10,80 15,20 16,00 IP 50 4,98 4,85 4,50 5,15 3,71 COP 50 1,77 1,98 2,40 2,95 4,31 HC 55 7,90 9,00 9,80 14,50 15,90 IP 55 4,95 4,99 4,55 5,45 3,93 COP 55 1,60 1,80 2,15 2,66 4,05 MONO-BLOC // HIGH-CONNECTIVITY // ON COOLING MODE // MDC MDC MODELS Tamb 16 25 35 43 HC 5,90 7,45 7,00 5,80 WH-MDC09 IP 1,01 1,59 2,25 2,59 COP 5,84 4,69 3,11 2,24 HC 7,65 9,20 10,00 7,60 WH-MDC12 IP 1,30 2,30 3,60 3,95 COP 5,88 4,00 2,78 1,92 HC 8,85 10,00 11,50 9,05 WH-MDC14 IP 1,50 2,68 4,40 5,01 COP 5,90 3,73 2,61 1,81 HC 9,62 10,51 12,20 10,08 WH-MDC16 IP 1,63 2,85 4,80 5,47 COP 5,90 3,69 2,54 1,84 67 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MXF WH-MXF09D3E5 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,88 2,45 COP 50 1,89 2,09 2,50 3,13 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-MXF12D6E5 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 11,50 12,00 12,00 12,00 13,40 IP 40 5,21 5,02 3,91 3,00 2,14 COP 40 2,21 2,39 3,07 4,00 6,26 HC 45 11,00 12,00 12,00 12,00 13,20 IP 45 5,42 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 10,70 12,00 12,00 12,00 12,60 IP 50 5,86 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 10,50 12,00 12,00 12,00 12,00 IP 55 6,30 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MXF09D3E8 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,88 2,45 COP 50 1,89 2,09 2,50 3,13 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-MXF12D9E8 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 12,00 12,00 12,00 12,00 13,40 IP 40 5,45 5,02 3,91 3,00 2,14 COP 40 2,20 2,39 3,07 4,00 6,26 HC 45 12,00 12,00 12,00 12,00 13,20 IP 45 5,90 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 11,50 12,00 12,00 12,00 12,60 IP 50 6,28 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 11,10 12,00 12,00 12,00 12,00 IP 55 6,66 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 BI-BLOC // AQUAREA T-CAP // ON COOLING MODE // SXC SXC MODELS Tamb 16 25 35 43 WH-SXC09 E8 HC 7,00 7,65 7,00 6,25 WH-SXC12 E8 IP 1,40 1,95 2,25 2,70 COP 5,00 3,92 3,11 2,31 HC 7,50 8,90 10,00 8,00 IP 1,45 2,20 3,60 3,05 HYDRAULIC PUMP PERFORMANCE EXTERNAL STATIC PRESSURE (kPa) ( 09D3 // 12D6 // 12D9 // 12D3 ) PUMP SPEED 3 PUMP SPEED 2 PUMP SPEED 1 WATER FLOW RATE (L/min) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 68 HC: Heating Capacity (kW) IP: Power Input (kW) LWC: Leaving Water Condenser Temperature (°C) Tamb: Ambient Temperature (°C) COP 5,17 4,05 2,78 2,62 AQUAREA BI-BLOC // AQUAREA T-CAP // HEATING ONLY // SXF WH-SXF09D3E5 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,80 2,45 COP 50 1,89 2,09 2,50 3,21 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-SXF12D3E5 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 11,50 12,00 12,00 12,00 13,40 IP 40 5,21 5,02 3,91 3,00 2,14 COP 40 2,21 2,39 3,07 4,00 6,26 HC 45 11,00 12,00 12,00 12,00 13,20 IP 45 5,42 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 10,70 12,00 12,00 12,00 12,60 IP 50 5,86 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 10,50 12,00 12,00 12,00 12,00 IP 55 6,30 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 WH-SXF09D3E8 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,80 2,45 COP 50 1,89 2,09 2,50 3,21 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-SXF12D3E8 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 12,00 12,00 12,00 12,00 13,40 IP 40 5,45 5,02 3,91 3,00 2,14 COP 40 2,20 2,39 3,07 4,00 6,26 HC 45 12,00 12,00 12,00 12,00 13,20 IP 45 5,90 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 11,80 12,00 12,00 12,00 12,60 IP 50 6,28 5,94 4,90 3,82 2,70 COP 50 1,88 2,02 2,45 3,14 4,67 HC 55 11,60 12,00 12,00 12,00 12,00 IP 55 6,66 6,30 5,51 4,20 2,93 COP 55 1,74 1,90 2,18 2,86 4,10 69 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MXF WH-MXF09D3E5 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,80 2,45 COP 50 1,89 2,09 2,50 3,21 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-MXF12D6E5 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 11,50 12,00 12,00 12,00 13,40 IP 40 5,21 5,02 3,91 3,00 2,14 COP 40 2,21 2,39 3,07 4,00 6,26 HC 45 11,00 12,00 12,00 12,00 13,20 IP 45 5,42 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 10,70 12,00 12,00 12,00 12,60 IP 50 5,86 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 10,50 12,00 12,00 12,00 12,00 IP 55 6,30 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 WH-MXF09D3E8 Tamb HC LWC 30 9,00 -15 9,00 -7 9,00 2 9,00 7 13,60 25 IP 30 3,28 2,75 2,40 1,68 1,54 COP 30 2,74 3,27 3,75 5,36 8,83 HC 35 9,00 9,00 9,00 9,00 13,60 IP 35 3,55 3,20 2,55 1,90 1,75 COP 35 2,54 2,81 3,53 4,74 7,77 HC 40 9,00 9,00 9,00 9,00 13,20 IP 40 3,95 3,66 2,82 2,20 1,97 COP 40 2,28 2,46 3,19 4,09 6,70 HC 45 9,00 9,00 9,00 9,00 12,80 IP 45 4,34 4,11 3,09 2,50 2,18 COP 45 2,07 2,19 2,91 3,60 5,87 HC 50 9,00 9,00 9,00 9,00 12,00 IP 50 4,77 4,31 3,60 2,80 2,45 COP 50 1,89 2,09 2,50 3,21 4,90 HC 55 9,00 9,00 9,00 9,00 11,20 IP 55 5,20 4,50 4,11 3,10 2,71 COP 55 1,73 2,00 2,19 2,90 4,13 WH-MXF12D9E8 Tamb HC LWC 30 12,00 -15 12,00 -7 12,00 2 12,00 7 13,60 25 IP 30 4,79 3,89 3,23 2,22 1,59 COP 30 2,51 3,08 3,72 5,41 8,55 HC 35 12,00 12,00 12,00 12,00 13,60 IP 35 5,00 4,45 3,53 2,57 1,80 COP 35 2,40 2,70 3,40 4,67 7,56 HC 40 11,50 12,00 12,00 12,00 13,40 IP 40 5,21 5,02 3,91 3,00 2,14 COP 40 2,21 2,39 3,07 4,00 6,26 HC 45 11,00 12,00 12,00 12,00 13,20 IP 45 5,42 5,58 4,29 3,43 2,47 COP 45 2,03 2,15 2,80 3,50 5,34 HC 50 10,70 12,00 12,00 12,00 12,60 IP 50 5,86 5,94 4,90 3,82 2,70 COP 50 1,83 2,02 2,45 3,14 4,67 HC 55 10,50 12,00 12,00 12,00 12,00 IP 55 6,30 6,30 5,51 4,20 2,93 COP 55 1,67 1,90 2,18 2,86 4,10 MONO-BLOC // AQUAREA T-CAP // ON COOLING MODE // MXC MXC MODELS Tamb 16 25 35 43 HC 7,00 7,65 7,00 6,25 WH-MXC09 IP 1,40 1,95 2,25 2,70 COP 5,00 3,92 3,11 2,31 HC 7,50 8,90 10,00 8,00 WH-MXC12 IP 1,45 2,20 3,60 3,05 HYDRAULIC PUMP PERFORMANCE EXTERNAL STATIC PRESSURE (kPa) ( 09D3 // 12D6 // 12D3 // 12D9 ) PUMP SPEED 3 PUMP SPEED 2 PUMP SPEED 1 WATER FLOW RATE (L/min) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 70 HC: Heating Capacity (kW) IP: Power Input (kW) LWC: Leaving Water Condenser Temperature (°C) Tamb: Ambient Temperature (°C) COP 5,17 4,05 2,78 2,62 AQUAREA BI-BLOC // AQUAREA HT // HEATING ONLY // SHF WH-SHF09D3E5 Tamb LWC -15 -7 2 7 HC 35 9 9 9 9 IP 35 3,75 3,33 2,65 1,98 COP 35 2,40 2,70 3,40 4,55 HC 45,00 8,80 8,90 9,00 9,00 IP 45,00 4,29 3,87 3,25 2,50 COP 45,00 2,05 2,30 2,77 3,60 HC 55,00 8,50 8,90 9,00 9,00 IP 55,00 4,94 4,49 3,91 3,16 COP 55,00 1,72 1,98 2,30 2,85 HC 65,00 7,80 8,90 9,00 9,00 IP 65,00 5,91 5,43 4,79 4,00 COP 65,00 1,32 1,64 1,88 2,25 WH-SHF12D6E5 Tamb LWC -15 -7 2 7 HC 30 9 9 9 9 IP 30 3,75 3,33 2,65 1,98 COP 30 2,40 2,70 3,40 4,55 HC 35 8,80 8,90 9,00 9,00 IP 35 4,29 3,87 3,25 2,50 COP 35 2,05 2,30 2,77 3,60 HC 40 8,50 8,90 9,00 9,00 IP 40 4,94 4,49 3,91 3,16 COP 40 1,72 1,98 2,30 2,85 HC 45 7,80 8,90 9,00 9,00 IP 45 5,91 5,43 4,79 4,00 COP 45 1,32 1,64 1,88 2,25 WH-SHF09D3E8 Tamb LWC -15 -7 2 7 HC 35 9 9 9 9 IP 35 3,75 3,33 2,65 1,98 COP 35 2,40 2,70 3,40 4,55 HC 45,00 8,80 8,90 9,00 9,00 IP 45,00 4,29 3,87 3,25 2,50 COP 45,00 2,05 2,30 2,77 3,60 HC 55,00 8,50 8,90 9,00 9,00 IP 55,00 4,94 4,49 3,91 3,16 COP 55,00 1,72 1,98 2,30 2,85 HC 65,00 7,80 8,90 9,00 9,00 IP 65,00 5,91 5,43 4,79 4,00 COP 65,00 1,32 1,64 1,88 2,25 WH-SHF12D9E8 Tamb LWC -15 -7 2 7 HC 30 9 9 9 9 IP 30 3,75 3,33 2,65 1,98 COP 30 2,40 2,70 3,40 4,55 HC 35 8,80 8,90 9,00 9,00 IP 35 4,29 3,87 3,25 2,50 COP 35 2,05 2,30 2,77 3,60 HC 40 8,50 8,90 9,00 9,00 IP 40 4,94 4,49 3,91 3,16 COP 40 1,72 1,98 2,30 2,85 HC 45 7,80 8,90 9,00 9,00 IP 45 5,91 5,43 4,79 4,00 COP 45 1,32 1,64 1,88 2,25 71 HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MHF WH-MHF09D3E5 Tamb LWC -15 -7 2 7 HC 35 9 9 9 9 IP 35 3,75 3,33 2,65 1,98 COP 35 2,40 2,70 3,40 4,55 HC 45,00 8,80 8,90 9,00 9,00 IP 45,00 4,29 3,87 3,25 2,50 COP 45,00 2,05 2,30 2,77 3,60 HC 55,00 8,50 8,90 9,00 9,00 IP 55,00 4,94 4,49 3,91 3,16 COP 55,00 1,72 1,98 2,30 2,85 HC 65,00 7,80 8,90 9,00 9,00 IP 65,00 5,91 5,43 4,79 4,00 COP 65,00 1,32 1,64 1,88 2,25 WH-MHF12D6E5 Tamb LWC -15 -7 2 7 HC 35 12 12 12 12 IP 35 5,58 4,80 3,72 2,73 COP 35 2,15 2,50 3,23 4,40 HC 45,00 10,80 11,20 11,30 12,00 IP 45,00 5,54 5,09 4,19 3,48 COP 45,00 1,95 2,20 2,70 3,45 HC 55,00 9,70 10,10 10,80 12,00 IP 55,00 5,81 5,32 4,91 4,32 COP 55,00 1,67 1,90 2,20 2,78 HC 65,00 8,00 9,60 10,30 12,00 IP 65,00 6,15 5,96 5,63 5,45 COP 65,00 1,30 1,61 1,83 2,20 WH-MHF09D3E8 Tamb LWC -15 -7 2 7 HC 35 9 9 9 9 IP 35 3,75 3,33 2,65 1,98 COP 35 2,40 2,70 3,40 4,55 HC 45,00 8,80 8,90 9,00 9,00 IP 45,00 4,29 3,87 3,25 2,50 COP 45,00 2,05 2,30 2,77 3,60 HC 55,00 8,50 8,90 9,00 9,00 IP 55,00 4,94 4,49 3,91 3,16 COP 55,00 1,72 1,98 2,30 2,85 HC 65,00 7,80 8,90 9,00 9,00 IP 65,00 5,91 5,43 4,79 4,00 COP 65,00 1,32 1,64 1,88 2,25 WH-MHF12D9E8 Tamb LWC -15 -7 2 7 HC 35 12 12 12 12 IP 35 5,58 4,80 3,72 2,73 COP 35 2,15 2,50 3,23 4,40 HC 45,00 10,80 11,20 11,30 12,00 IP 45,00 5,54 5,09 4,19 3,48 COP 45,00 1,95 2,20 2,70 3,45 HC 55,00 9,70 10,10 10,80 12,00 IP 55,00 5,81 5,32 4,91 4,32 COP 55,00 1,67 1,90 2,20 2,78 HC 65,00 8,00 9,60 10,30 12,00 IP 65,00 6,15 5,96 5,63 5,45 COP 65,00 1,30 1,61 1,83 2,20 HYDRAULIC PUMP PERFORMANCE EXTERNAL STATIC PRESSURE (kPa) ( 09D3 // 12D6 // 12D9 ) PUMP SPEED 3 PUMP SPEED 2 PUMP SPEED 1 WATER FLOW RATE (L/min) This data is measured by Panasonic in accordance with EN14511-2 standard. This data is for reference purpose only, and does not guarantee the performance. 72 HC: Heating Capacity (kW) IP: Power Input (kW) LWC: Leaving Water Condenser Temperature (°C) Tamb: Ambient Temperature (°C) AQUAREA AQUAREA PRO // ECOi + U-250WX2E5 // HEATING MDC Tamb LWC -15 -7 2 7 25 HC 30 IP 30 COP 30 HC 35 IP 35 COP 35 HC 40 22,90 25,80 31,40 31,50 31,50 IP 40 9,76 10,3 11,0 9,75 6,83 COP 40 2,34 2,50 2,85 3,23 4,61 HC 45 20,70 23,40 28,00 28,00 28,00 IP 45 8,83 9,26 9,64 8,61 6,06 COP 45 2,34 2,52 2,90 3,25 4,62 HC 50 IP 50 COP 50 HC 55 IP 55 COP 55 HC 40 42,40 48,00 56,00 56,00 56,00 IP 40 19,4 20,5 21,0 18,1 12,8 COP 40 2,18 2,34 2,66 3,09 4,37 HC 45 39,30 44,90 51,30 51,30 51,30 IP 45 17,5 18,5 18,4 16,5 11,5 COP 45 2,24 2,42 2,78 3,10 4,46 HC 50 IP 50 COP 50 HC 55 IP 55 COP 55 AQUAREA PRO // ECOi + U-500WX2E5 // HEATING MDC Tamb LWC -15 -7 2 7 25 HC 30 IP 30 COP 30 HC 35 IP 35 COP 35 73 ACCESSORIES THIRD PARTY TANKS FIELD PROCURED OPTIONAL PARTS High Efficiency Tank Water volume Max. water temperature Dimension. High Diameter Weight Electric heater Power supply Material inside tank Exchange surface Energy loss at 65°C insulated tested under EN12897 3 Way valve included HR 200* 200 95 1340 600 108 3 230V enamelled 1,80 m2 kWh/24h 1,8 L °C mm mm kg kW YES Super High Efficiency Tank HR 300* 300 95 1797 600 140 3 230V enamelled 2,60 2,2 HRS 300* 300 95 1435 680 170 3 230V enamelled 3,50 2,2 HRS 500* 500 95 1806 760 254 3 230V enamelled 6,00 2,7 YES YES YES SOLAR KIT Brand Model No. RESOL FlowConS_DeltaSol_BS_Plus Oventrop Regusol X-25 3 WAY-VALVE Brand Model No. Siemens SFA21/18 / VXI46/25 2 WAY VALVE Brand Model No. Honeywell V4043C1007 Siemens SFA21/18 // VVI46/25 ROOM THERMOSTAT ON / OFF Brand Model No. Siemens RAA20 Siemens REV200 THERMAL VALVE Brand Model No. Taconova RA57 Danfoss AVB-NC Feature Remote Control Remote Control Feature Spring return Feature Spring return Spring return Feature Dial type Programme Feature NC NC PANASONIC ACCESSORIES SOLAR KIT ACCESSORIES CZ-NS1P Solar connection PCB (for Bi-split type) CZ-NS3P Solar connection PCB (for Mono-bloc type) CZ-NS2P Solar connection PCB (for Mono-bloc) SANITARY TANK ACCESSORIES CZ-TK1 Temperature sensor kit for third party tank CZ-TK3 Temperature sensor kit for third party tank for mini Monobloc DEICE ACCESSORIES CZ-NE1P Base pan heater kit RESOL FlowConS_DeltaSol_ BS_Plus HR200* HRS300* Danfoss AVB-NC HR300* HRS500* * Panasonic’s term of warranty is based on the warranty conditions provided by the tank supplier being met. Please ensure the maintenance programme is carried out as instructed in the tank manufacturer’s manual. 74 Oventrop REGSOL UNO X-15 Siemens REV200 Taconova RA57 SIEMENS. 2-way valve Morter : SFA21/18 Valve body : VVI46/25 Siemens RAA20 SIEMENS. 3-way valve Morter : SFA21/18 valve body : VXI46/25 AQUAREA THE OPERATION LED BLINKS AND AN ERROR CODE APPEARS ON THE CONTROL PANEL DISPLAY. FORCE HEATER MODE BUTTON · The backup heater also serves as backup in case of malfunctioning of the outdoor unit. · Turn the unit off and inform the authorised dealer of the error · Press to stop the force heater operation. code. · During Force Heater mode, all other operations are not allowed. · The timer operation is cancelled when an error code occurs. ERROR CODES TABLE Diagnosis display H00 H12 Abnormality / Protection control No abnormality detected Indoor/Outdoor capacity unmatched Abnormality Judgement — 90s after power supply H15 H23 H38 H42 Outdoor compressor temperature sensor abnormality Indoor refrigerant liquid temperature sensor abnormality Indoor/Outdoor mismatch Compressor low pressure abnormality Continue for 5 sec. Continue for 5 sec. — — H62 H64 H70 H72 H76 H90 Water flow switch abnormality Refrigerant high pressure abnormality Back-up heater OLP abnormality Tank sensor abnormal Indoor - control panel communication abnormality Indoor / outdoor abnormal communication Continue for 1 min. Continue for 5 sec. Continue for 60 sec. Continue for 5 sec. — > 1 min after starting operation H91 H95 H98 Tank heater OLP abnormality Indoor/Outdoor wrong connection Outdoor high pressure overload protection Continue for 60 sec. — — H99 Indoor heat exchanger freeze prevention — F12 F14 F15 Pressure switch activate Outdoor compressor abnormal revolution Outdoor fan motor lock abnormality 4 times occurrence within 20 minutes 4 times occurrence within 20 minutes 2 times occurrence within 30 minutes F16 Total running current protection 3 times occurrence within 20 minutes F20 Outdoor compressor overheating protection 4 times occurrence within 30 minutes F22 IPM (power transistor) overheating protection 3 times occurrence within 30 minutes F23 Outdoor Direct Current (DC) peak detection 7 times occurrence continuously F24 Refrigeration cycle abnormality 2 times occurrence within 20 minutes F25 Cooling / Heating cycle changeover abnormality 4 times occurrence within 30 minutes F27 F36 F37 F40 F41 F42 F43 F45 F46 Pressure switch abnormality Outdoor air temperature sensor abnormality Indoor water inlet temperature sensor abnormality Outdoor discharge pipe temperature sensor abnormality PFC control Outdoor heat exchanger temperature sensor abnormality Outdoor defrost sensor abnormality Indoor water outlet temperature sensor abnormality Outdoor Current Transformer open circuit Continue for 1 min. Continue for 5 sec. Continue for 5 sec. Continue for 5 sec. 4 times occurrence within 10 minutes Continue for 5 sec. Continue for 5 sec. Continue for 5 sec. — F95 Cooling high pressure overload protection — Primary location to verify — · Indoor/outdoor connection wire · Indoor/outdoor PCB · Specification and combination table in catalogue · Compressor temperature sensor (defective or disconnected) · Refrigerant liquid temperature sensor (defective or disconnected) · Indoor/Outdoor PCB · Outdoor pipe temperature sensor · Clogged expansion valve or strainer · Insufficient refrigerant · Outdoor PCB · Compressor · Water flow switch · Outdoor high pressure sensor (defective or disconnected) · Back-up heater OLP (Disconnection or activated) · Tank sensor · Indoor - control panel (defective or disconnected) · Internal / external cable connections · Indoor / Outdoor PCB · Tank heater OLP (Disconnection or activated) · Indoor/Outdoor supply voltage · Outdoor high pressure sensor · Water pump or water leakage · Clogged expansion valve or strainer · Excess refrigerant · Outdoor PCB · Indoor heat exchanger · Refrigerant shortage · Pressure switch · Outdoor compressor · Outdoor PCB · Outdoor fan motor · Excess refrigerant · Outdoor PCB · Compressor tank temperature sensor · Clogged expansion valve or strainer · Insufficient refrigerant · Outdoor PCB · Compressor · Improper heat exchange · IPM (Power transistor) · Outdoor PCB · Compressor · Insufficient refrigerant · Outdoor PCB · Compressor low compression · 4-way valve · V-coil · Pressure switch · Outdoor air temperature sensor (defective or disconnected) · Water inlet temperature sensor (defective or disconnected) · Outdoor discharge pipe temperature sensor (defective or disconnected) · Voltage at PFC · Outdoor heat exchanger temperature sensor (defective or disconnected) · Outdoor defrost sensor (defective or disconnected) · Water outlet temperature sensor (defective or disconnected) · Insufficient refrigerant · Outdoor PCB · Compressor low · Outdoor high pressure sensor · Water pump or water leakage · Clogged expansion valve or strainer · Excess refrigerant · Outdoor PCB 75 www.panasonic.eu To find out how Panasonic cares for you, log on to: www.panasonic.eu Contact Details: Telephone: 01344 853182 www.panasonic.co.uk/aircon Address: Panasonic Air Conditioning Panasonic House Willoughby Road Bracknell Berkshire RG12 8FP Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd. www.eggeassociats.net
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement