General catalogue Panasonic AQUAREA 2012 EN

General catalogue Panasonic AQUAREA 2012 EN
AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS
NEW
2012
2012
‘ECO IDEAS’ FOR LIFESTYLES: WE WILL PROMOTE
LIFESTYLES WITH VIRTUALLY ZERO CO2 EMISSIONS
THROUGHOUT THE WORLD. SPECIFICALLY:
· 30% of total sales will be achieved through “eco
labeled” products. This includes both external labels
such as EU eco flower, Blue Angel or Nordic Swan,
and our internal ‘eco ideas’ label, which is given to
products which achieve industry-leading environmental
performance. 1)
· 3,500,000t of contribution in reducing CO2 emissions
with energy solution products (such as Solar Panels,
Fuel Cells, Heat Pumps, Energy Recovering Ventilation,
LED and Energy Saving Lamps). 2)
· Educate 100,000 children on eco related topics through
the ‘kids school – eco learning’ programme.
‘ECO IDEAS’ FOR BUSINESS-STYLES: WE WILL CREATE
AND PURSUE BUSINESS-STYLES THAT MAKE THE BEST
USE OF RESOURCES AND ENERGY:
· 99% of waste materials generated in European
production will be recycled 3), meaning less than 1%
will be allowed to go to landfill.
· 1,000t of reduction in CO2 emissions from Panasonic’s
offices across Europe. 4)
· 7,000t of contribution in reducing CO2 emissions from
production activities. 5)
1) Products awarded the ‘eco ideas’ label include those whose environmental performance is greater
than the industry’s No.2 model by 10% or more at the time of release, and those which achieve
the highest rank in the market by external environmental labels in accordance to environmental
performance.
2) An amount of CO2 reduction compared to the estimated figure assuming no improvement.
Measures were taken after March 31, 2006.
3) Includes all Panasonic Group’s European factories with the exception of IPS-Alpha and Panasonic
4) Based on offices with 100 employees or more; based on FY 2009.
5) An amount of CO2 reduction compared to the estimated figure assuming no improvement.
Measures were taken after March 31, 2006.
2
PANASONIC GLOBAL VISION
The Panasonic Group strives to be a green innovation company with a global perspective. Its
aim is to be the leading green company in the electronics sector by 2018 - the year that
Panasonic celebrates its centenary.
HEATING & COOLING
Panasonic Home Appliances is the European leader in heating and cooling solutions for the
home. When it comes to market share, Panasonic is the No. 1 company for home solutions in
Europe, the No. 1 company for domestic cooling & heating solutions in Spain, and the No. 1
company for heating systems in the Nordic countries.
Panasonic invests significantly in Research & Development, with a strong network of design,
manufacturing and training centres throughout Europe. As part of Panasonic’s continued
programme of growth, a new R&D facility is open in Langen, Germany. The centre is focused on
developing products to meet the needs of European customers, as well as European legislation.
ECO IDEAS FOR LIFESTYLES
Panasonic is making the environment central to all of its business activities. It will become the
No 1 green innovation company in the electronics sector through its eco ideas initiative: eco
ideas for lifestyles to change people’s lives and eco ideas for business to bring forth green
innovation in Panasonic’s own global business operations.
Panasonic always strives to offer better living, with a sense of joy, security and comfort, as well
as with virtually zero CO2 emissions in the entire house or building.
ECO IDEAS FOR BUSINESS
Panasonic will create and pursue a business-style which makes the best use of resources and
energy. As well as making eco-conscious products and delivering them to customers,
Panasonic aims to reduce waste of energy and resources during the manufacturing process. As
well as tackling its own business, Panasonic will take a leading role for sharing and working
on environmental challenges in entire societies.
SUMMARY
PANASONIC – LEADING THE WAY IN HEATING & COOLING .................................................................. 4
IDEAS FOR A CLEANER FUTURE ........................................................................................................ 6
REALISING ECO-CONSCIOUS SOLUTIONS IN ENTIRE TOWNS............................................................... 8
PANASONIC PROFESSIONAL ........................................................................................................... 10
AQUAREA’S NEW AIR-TO-WATER HEAT PUMP .................................................................................. 12
"GREEN" HIGH-EFFICIENCY ............................................................................................................ 14
NEW LINE-UP ................................................................................................................................ 16
NEW AQUAREA 3 AND 5 KW BI-BLOC AND 6 AND 9 KW MONO-BLOC AIR TO WATER HEAT .................. 18
HEAT PUMP + PHOTOVOLTAIC ......................................................................................................... 20
INVERTER+ COMPRESSOR FOR EVEN GREATER EFFICIENCY ............................................................. 22
WHAT MAKES THE AIR-TO-WATER HEAT PUMP WORK ...................................................................... 24
CONTROL YOUR HEAT PUMP WITH YOUR SMART DEVICE -SMARTPHONE & INTERNET- ...................... 26
CONNECTIVITY ............................................................................................................................... 28
HP BI-BLOC AND MONO-BLOC APPLICATION EXAMPLES .................................................................. 30
AQUAREA LINE-UP ......................................................................................................................... 32
BI-BLOC // HIGH CONNECTIVITY // 3 AND 5 KW AQUAREA // HEATING ONLY - SDF //
HEATING AND COOLING - SDC......................................................................................................... 34
AQUAREA MDF & MDC // MONO-BLOC // HIGH CONNECTIVITY // 6 AND 9 KW AQUAREA //
HEATING AND COOLING // SINGLE-PHASE ....................................................................................... 36
AQUAREA SDF // BI-BLOC // HIGH CONNECTIVITY // HEATING ONLY SINGLE-PHASE // THREE-PHASE....... 38
AQUAREA SDC // BI-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING SINGLE-PHASE //
THREE-PHASE ............................................................................................................................... 40
AQUAREA MDF // MONO-BLOC // HIGH CONNECTIVITY // HEATING ONLY SINGLE-PHASE //
THREE-PHASE ............................................................................................................................... 42
AQUAREA MDC // MONO-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING
SINGLE-PHASE // THREE-PHASE..................................................................................................... 44
AQUAREA SXF // BI-BLOC // T-CAP // HEATING ONLY SINGLE-PHASE // THREE-PHASE ....................... 46
AQUAREA SXC // BI-BLOC // T-CAP // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE.......... 48
AQUAREA MXF // MONO-BLOC // T-CAP // HEATING ONLY SINGLE-PHASE // THREE-PHASE ................ 50
AQUAREA MXC // MONO-BLOC // T-CAP // HEATING AND COOLING SINGLE-PHASE // THREE-PHASE... 52
AQUAREA SHF // BI-BLOC // HT // HEATING ONLY SINGLE-PHASE // THREE-PHASE ............................ 54
AQUAREA MHF // MONO-BLOC // HT // HEATING ONLY SINGLE-PHASE // THREE-PHASE..................... 56
AQUAREA PRO // THE NEW PANASONIC SOLUTION FOR CHILLED AND HOT WATER PRODUCTION! ...... 58
AQUAREA PRO // NEW ECOI 2-WAY 6 SERIES WITH WATER HEAT EXCHANGER .................................. 60
AQUAREA PRO // NEW GAS VRF ECO G WITH WATER HEAT EXCHANGER ............................................ 62
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE ............... 64
ACCESSORIES ................................................................................................................................ 66
3
PANASONIC – LEADING THE WAY
IN HEATING & COOLING
With more than 30 years of experience, selling to more than
120 countries around the world, Panasonic is unquestionably
one of the leaders in the heating and cooling sector.
HISTORY OF AIR
CONDITIONING
GROUP
Panasonic starts with a
desire to create things
of value. As hard work
and dedication results
in one innovative
product after another,
the fledgling company
takes its first steps
towards becoming the
electronics giant of
today.
4
1936
1958
1973
1975
First electric Fan with
Automatic Oscillation (36 cm
table top model).
First room air conditioner launched
for domestic installation.
Prior to this date, air conditioners
were large and only for commercial
use. Panasonic developed the
first compact air conditioner for
windows; it was lightweight and
easy to install, improving the
quality of life in Japanese homes.
1,100 units were sold in Japan in
the first year, and just two years
later, in 1960, this figure rose to
230,000.
Panasonic launches the first
highly efficient air-to-water
heat pump in Japan.
Panasonic becomes
the first Japanese air
conditioner
manufacturer in Europe.
EDITORIAL
The company is also a world leader in innovation as it has filed more than
91539 patents to improve its customers’ lives. Moreover, Panasonic is
determined to remain at the forefront of its market. In all, the company has
produced more than 200 million compressors and its products are
manufactured in 294 plants which are located all over the world. You can be
assured of the extremely high quality of Panasonic’s heat pumps.
This wish to excel has made Panasonic the international leader in heating
and air conditioning solutions of turnkey for homes, medium-sized buildings
such as offices and restaurants, and large-scale buildings. These offer
maximum effectiveness, comply with the strictest environmental standards
and meet the most avant-garde construction requirements of our time.
At Panasonic we know what a great responsibility it is to install heating and
cooling systems. Because offering you the best solutions in heating and
cooling matters.
PANASONIC EUROPE
Panasonic is committed to offering our
customers innovative products in the heating
and cooling market across Europe, which not
only meet but exceed their requirements. Key
to success is Panasonic’s investment in R&D,
manufacture and training to ensure innovative,
cutting edge products and investment in our
distribution channels and partners so that
these products are accessible in Europe.
Panasonic has developed a comprehensive
network across Europe of training centers and
training academies for installers, design offices
and service teams in all major countries.
PANASONIC FACTORIES
AND R&D DEPARTMENT
There is a close relationship between R&D
innovation and good manufacturing
processes, and so Panasonic has placed its
R&D facilities very close to its
manufacturing bases. This ensures good
integration between all divisions to deliver
high quality and reliable solutions to our
markets.
2002
2008
2010
2011
2012
The Ion and Oxygen
Generator — two of the
most important contributions
to air conditioning systems.
Etherea new concept of
air conditioning systems:
high efficiency and high
performances with a great
design. Etherea also includes a
very innovative air quality sensor
and air purifier in order to enjoy
healthy air at home at all times.
New Aquarea
Panasonic has created Aquarea,
an innovative new, low-energy
system, designed to help you
enjoy ideal temperatures and
hot water in your home, even with
extreme outdoor temperatures.
Aquarea cools or heats to ensure
maximum comfort.
Aquarea is far cleaner, safer,
cheaper and environmentally
friendly than alternatives
using gas, oil and other electrical
systems.
New Eco i VRF solution
The new Panasonic VRF solution
for big buildings is the most
efficient in the industry in more
than 74% of combinations. ECO
i satisfies the most demanding
standards required by design
offices, architects, owners and
installers.
New GHP units
Pansonic’s gas-driven VRF
systems are ideal for projects
where power restrictions apply.
In 2012, Panasonic extends the
Gas Heat Pump range with a new
GHP line-up, new GHP G Power
(electricity production) and the
new Chiller Units.
5
LIVING ECO-FRIENDLY
Panasonic is globally committed to developing environmentally-conscious products in the following three aspects: global warming prevention,
effective resources utilisation and chemical substances management. In particular, we have been striving to increase a rate of products with industry-leading
energy efficiency and phase out those with low performance, with the aim of contributing to the prevention of global warming. In the ‘eco ideas’ House, which
embodies a lifestyle with virtually zero CO 2 emissions and that will be realised in three to fi ve years into the future, we are proposing wide-ranging ideas that create
comfortable lifestyles with minimum energy consumption, as well as presenting products and services that make full use of our original environmental technologies. Furthermore, to face the challenge of stepping up to the new field from the enhancement of products’ energy efficiency, Panasonic is promoting the development of energy-saving equipment such as heat pumps, fuel cells and solar power generators as well as energy-storing devices.
6
EDITORIAL
Ideas for a Cleaner Future
Panasonic is committed to developing environmentally-conscious products from
three aspects, such as prevention of global warming, effective utilisation of
resources and chemical substances management.
ENERGY MANAGEMENT
CREATE ENERGY
The SEG (Smart Energy Gateway) connects
residential energy sources with smart appliances
with a wireless network and a server.
Solar Cells and Fuel Cells to create energy more
cleanly and efficiently
PHOTOVOLTAIC
LED LAMP
AIR-CONDITIONER
WASHING
MACHINE
REFRIGERATOR
ENERGY
MANAGEMENT
SYSTEM
VENTILATION
SYSTEM
FUEL
CELL
STORAGE
BATTERY
HEAT PUMP
STORE ENERGY
SAVE ENERGY
Residential lithium-ion batteries for a stable energy
supply
From top resource savings to efficient heating –
Panasonic offers many eco-friendly appliances: LED/
ESL, ERV, Air Conditioner, Washing Machine, Fridge,
Heat Pump
In an era when the world is tackling the reduction of CO 2 emissions, Panasonic proposes a lifestyle with virtually zero CO 2 emissions throughout the entire
home. CO 2 emissions are thoroughly reduced by enhancing energy-saving performance of home appliances and utilising building materials with high insulation
performance. And energy required will be supplied by creating and storing energy by a combination of solar power generators, fuel cells and storage batteries.
The Panasonic energy management system realises a lifestyle with virtually zero CO2 emissions by linking these benefits together and smartly controlling all
energy use. Meanwhile, intelligent use will also be made of natural elements such as air, light, water and heat to realise a more comfortable lifestyle. Experience an ecological and comfortable lifestyle that only Panasonic can present.
7
REALISING ECO-CONSCIOUS
SOLUTIONS IN ENTIRE TOWNS
8
TIANJIN ECO-CITY
Panasonic is taking part in a pioneering project by China and
Singapore to create the Tianjin Eco-City, some 40 km from
Tianjin city centre and 150 km from Beijing. Designed to be
practical, replicable and scalable, the Tianjin Eco-city will
demonstrate the determination of both countries in tackling
environmental protection, resource and energy conservation,
and sustainable development, and serve as a model for
sustainable development for other cities in China. By 2020,
there will be around 30 square kilometres of city capable of
accommodating a population of around 400,000.
EDITORIAL
HOME ENERGY MANAGEMENT SYSTEM
Panasonic is supplying each of the houses built in Tianjin Eco-City with a
mini-VRF air conditioning system with Home Energy Management System
(HEMS). The HEMS will be central to saving energy in homes. By linking a
whole range of domestic appliances, solar power generation equipment,
electric vehicle chargers, storage batteries and other devices, the HEMS
shows the amount of energy being used in the home. The system will
indicate whether or not energy-saving goals are being achieved and will
display advice on where further savings could be made.
By using easily-read displays on all screens throughout the home,
homeowners will become more conscious of energy-saving activities and
adopt a more natural and eco-friendly lifestyle.
FUJISAWA SUSTAINABLE SMART TOWN
Panasonic is converting its former factory site in Fujisawa City in Japan,
50 km west of Tokyo, into a smart town deploying services and energy
systems based on Panasonic’s eco ideas for green lifestyles. Panasonic
is working in partnership with eight other companies and Fujisawa City
to build an innovative smart town. The developers, manufacturers and
service providers will work closely together throughout every phase of the
project, from the master planning stage to actual operation of the town
that will have about 1,000 households spread over 19 hectares.
Homes will employ the full range of Panasonic’s most advanced systems
for energy production, storage and management. Houses will be fully selfsufficient by generating power from efficient solar modules and fuel cell
systems, with energy stored in powerful lithium-ion batteries. Low energy
lighting, air conditioning and household appliances will be interconnected
via a computer system, and televisions and PCs will be used to display
energy consumption and tips on savings.
9
PANASONIC PROFESSIONAL
Panasonic has an impressive range of support services for
designers, specifiers, engineers and distributors working in
the heating and cooling markets.
SOFTWARE
Panasonic provides bespoke software helping system designers, installers
and dealers to very quickly design and size systems, create wiring
diagrams and issue bills of quantities at the push of a button.
ECOI VRF DESIGNER
The VRF Designer Software is very easy to use. By using
it, engineers can develop projects quickly, by either using
the drag and drop icons or the project wizard. It comes
fully loaded with all appropriate Panasonic product
details and is designed with flexibility in mind so that several different
system designs can be created within one project.
The program will check system designs and correction factors are
automatically applied to indoor unit capacities, depending on height
differences, piping lengths, indoor/outdoor capacity ratio and design
conditions. VRF Designer will also calculate any additional amounts
of refrigerant that may be required, based on configuration and piping
lengths.
Existing projects can easily be modified or even extended at a later stage.
Reports can be exported and printed showing piping and wiring diagrams,
power supply diagrams as well as bill of quantities.
10
AQUAREA DESIGNER
This program allows HVAC designers, installers and
distributors to identify the correct heat pump for a particular
application from Panasonic’s Aquarea range, calculate
the savings compared to other heat sources and very quickly calculate CO2
emissions.
Using Panasonic’s Aquarea Designer, projects can be developed simply and
easily, by either using the Quick Design or Expert Design options. Each allows
the user to build up the project data in a simple step-by-step process and
choose to output reports (in either Quick or Large formats) as HTML files or
as print outs.
Aquarea Designer will calculate the project’s energy costs in terms of hot
water, heating and pumping. It will show the equipment running times and
calculate the COP (coefficient of performance). It then allows the designer to
show clients a comparison with other equipment options such as heating by
conventional gas-fired boilers, oil systems, wood, standard electric heating
and electric night storage heaters. This compares running costs, initial
investment costs and maintenance costs. The comparison can also be made
for CO2 emissions and savings.
iPAD APP
For a quick and easy introduction to the
Aquarea Heat Pump range, the iPad app
can be used to show clients the benefits of
this energy-efficient heating and hot water
system.
EDITORIAL
NEW
PRO CLUB
PRO Club
PANASONIC PRO CLUB
THE PANASONIC PRO-ACADEMY OPENS ITS DOORS
Panasonic announces a new initiative for all professionals involved in the heating
and cooling business - the Panasonic PRO Club (www.panasonicproclub.com).
This exciting new portal provides distributors, installers, engineers and specifiers
with a direct communication channel with one of the industry’s major
manufacturers.
The website contains a wealth of information from the latest versions of
Panasonic’s Aquarea and Etherea Design Software, to Technical Documentation,
Catalogues and Images for the company’s wide range of heating and cooling
systems - all in an easy to navigate and use website.
Also, registered users will be able to access news regarding special promotions
and take advantage of these offers, as well as access helpful business advice
such as ideas and guidelines for showroom decoration or van livery featuring
Panasonic logos and display material.
Panasonic takes its responsibility to its distributors, specifiers and installers
seriously and has developed a comprehensive Training Programme. The
Panasonic Pro-Academy encompasses the traditional hands-on approach, as
well as embracing today’s technology to offer an eLearning facility available
24 hours, 7 days a week!
www.panasonicproclub.com
or connect simply with your smartphone to the proclub using this QR:
NEW TRAINING COURSES COVER THREE LEVELS
Design, installation, and commissioning & trouble-shooting
Training courses include:
· VRF ECOi
· Aquarea air source heat pumps (MCS accredited)
· GHP (2012)
The courses are offered on site at Panasonic’s premises across Europe as well
as via the Panasonic ProClub eLearning site. The Training Centres display
Panasonic’s latest product range and give delegates an opportunity to get
hands-on experience with the latest controllers, indoor and outdoor units from
the VRF ECOi, Etherea, GHP and Aquarea ranges.
11
NEW
2012
AQUAREA’S NEW AIR-TO-WATER HEAT PUMP FOR
RESIDENTIAL APPLICATIONS
Offering capacities from 3kW to 16kW, the Aquarea Heat Pump Range is
the biggest line-up on the market, designed to meet all your heating and
cooling demands. Cost-effective and environmentally friendly.
AQUAREA’S NEW AIR-TO-WATER HEAT PUMP
FOR RESIDENTIAL COMMERCIAL, AND CHILLER
APPLICATIONS
Up to 80 kW capacity from an easy-to-install system providing impressive
efficiency, even at outdoor temperatures as low as -20°C.
*
O
*
*
European Quality Label
for Heat Pumps
ehpa
* Not all products certified. As the certification process is on-going and the list of certified products constantly changing, please check for latest
details on the official websites.
12
AQUAREA
PANASONIC’S NEW AQUAREA AIR-TO-WATER SYSTEM PROVIDES MAXIMUM
EFFICIENCY AND CAPACITY EVEN AT -15 °C
Panasonic’s new Aquarea system, based on high-efficiency heat pump technology, not only heats your home and hot water,
but also cools your home in summer with incredible operating performance. This creates perfect comfort whatever the
weather conditions, even at outdoor temperatures as low as -15°C.
Panasonic new heat pumps are designed in response to the new demand for low consumption housing, with high
efficiency and low running cost's.
high
efficiency
heating
environmentally
friendly
refrigerant
R410A
INVERTER+ SYSTEM
The A Inverter+
system provides
energy savings of up
to 30% compared to
non inverter models.
Both you, and nature,
wins!
REFRIGERANT R410A
/ R407C
R410A / R407C offers
optimal performance
and involves no
environmental cost
since it does not harm
the ozone layer.
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
UP TO -20°C IN
HEATING MODE
The air conditioner
works in heat
pump mode with an
outdoor temperature
as low as -20ºC.
solar
panels
connection
domestic
hot
water
RETROFIT
SOLAR KIT
DHW
RENOVATION
Our Aquarea heat
pumps can be
connected to an
existing or new boiler
for optimum comfort
even at very low
outdoor temperatures.
SOLAR KIT
For even greater
efficiency, our
Aquarea heat pumps
can be connected
to photovoltaic
solar panels with an
optional kit.
DHW
With Aquarea you
can also heat your
domestic hot water
at a very low cost
with the optional hot
water cyclinder.
5 year
compressor
warranty
5 YEARS WARRANTY
We guarantee the
compressors in the
entire range for five
years.
13
"GREEN" HIGH-EFFICIENCY HEATING
WITH PANASONIC'S NEW AIR-TO-WATER
HEAT PUMP SYSTEMS
At the forefront of energy innovation, Aquarea is resolutely
positioned as a “green” heating and air-conditioning system.
Aquarea is part of a new generation of heating and air-conditioning
systems that use a renewable, free energy source – the air – to heat or
cool the home and to produce hot water. The Aquarea heat pump is a much
more flexible and cost-effective alternative to a traditional fossil fuel
boiler.
We are surrounded by an endless supply of free energy: supplied by the
sun and present in all spheres of our environment, the air, the ground, the
groundwater...
An ideal heating solution for both new and old properties:
· A wide range from 3 to 16 kW, single and three phase, mono-bloc and bi-bloc
· 3 Versions:
- The Standard Heat Pump
- The High Temperature Heat Pump (output water temperature of 65°C)
- The Total Capacity Heat Pump even at -15ºC
· The High-efficiency Heat Pump which operates at outside temperatures as
low as –20ºC
· Reduces energy costs with its COP of 4.74*
· Reduces energy consumption and CO2 emissions
· Provides cooling in summer
· Highly flexible:
- Connects to an existing heating system
- Connects to photovoltaic solar panels
Thus, Panasonic’s Aquarea system is an air/water heat pump system that
uses energy from the outdoor air and transmits them via a heat exchanger
to the water used to heat your home in winter, in addition, some Aquarea
models can even be used to cool your house in summer time and produce
hot water all year round.
Heat pumps enable us to recover this free, inexhaustible energy and
to harness its power to heat our homes. These systems have the huge
advantage, apart from reducing your electricity bill, of saving fossil fuels
and at the same time limiting greenhouse gas emissions*.
* We note that ADEME (French environmental and energy management agency) encourages consumers to choose heating and cooling
systems that use heat pump systems.
* COP: energy efficiency in heating mode. COP of 4.74 for the 9kW WH-MDF09C9E8 or WH-UD09CE8 models at an outside temperature of 7 ºC, and for water. input and output temperatures of 30 °C and 35 °C (according to EN 14511-2)
We note that ADEME (French environmental and energy management agency) encourages consumers to choose heating and cooling systems that use heat pump systems.
14
AQUAREA
UUPP TO
TO
78%
eenergy
ener
ene
nerg
nerg
rgy
gyy ssavings
av
avin
ingss1
ing
NEW
3 & 5 kW
UP TO 78% ENERGY SAVINGS*
Panasonic’s Aquarea heat pump provides savings of up to 78% on heating
expenses compared with electrical heaters. For example, the Aquarea
9kW system has a COP of 4.74. This is 3.74kW more than a conventional
electrical heating system which has a maximum COP of 1. This is equivalent
to a 78% saving.
Consumption can be further reduced by connecting photovoltaic solar
panels to the Aquarea system.
AQUAREA
UP TO 78%
ENERGY SAVINGS*
GAS
BOILER
ELECTRICAL
HEATING
OIL
BOILER
0,78
kW
1kW
0,9kW
1kW
0,9kW
1kW
1kW
GAS
HEAT
OIL
HEAT
ELECTRICITY
HEAT
RENEWABLE
ENERGY
0,22kW
ELECTRICITY
78%
OUTDOOR
ENERGY
1kW
HEAT
22%
ELECTRICITY
OTHER HEATING SYSTEMS
POWER INPUT / ENERGY CONSUMPTION
POWER OUTPUT / HEATING CAPACITY (KW)
* Up to 78% of the heat produced by a heat pump is free, since it comes from the outdoor air. Rating conditions: Heating: Inside air temperature: 20°C Dry Bulb /
Outside air temperature: 7°C Dry Bulb / 6°C Wet Bulb. Conditions : Water input temperature: 30 °C Water output temperature: 35 °C
15
PANASONIC HAS DESIGNED A COMPLETELY NEW LINE-UP TO
GIVE THE BEST TO OUR CUSTOMERS
THERE ARE SEVERAL TYPES OF HEAT PUMP AVAILABLE:
The mono-bloc system
The bi-bloc system
This only has an outdoor unit. The installation doesn’t require a
refrigerated connection and is only connected to the heating
system.
This system is made up of an outdoor unit and a hydraulic module,
normally located in the utility room or garage.
*
*
*
*
* Tank Optional
16
* Tank Optional
AQUAREA
AQUAREA INCREASE LINE-UP!
· New 3 and 5 KW Bi-bloc for low energy homes
· New 6 and 9 KW Mono-bloc Heat Pumps for low energy homes
· New line-up of high temperature Heat Pumps (output water temperature of 65°C)
WHICH PRODUCT FOR WHICH APPLICATION?
4.74* COP
100%
output
water
high
efficiency
AQUAREA
HIGH CONNECTIVITY
65ºC
capacity
at -15°C
HIGH TEMP
HEAT PUMP
AQUAREA T-CAP
AQUAREA HIGH CONNECTIVITY
AQUAREA HT
AQUAREA T-CAP
For a house with low temperature radiators or
under-floor heating, our high connectivity Aquarea
heat pump is a good solution. This solution can
work as a stand-alone unit or can be combined
with a gas- or oil-fired depending on requirements.
For a house with high temperature radiators (for
example, cast iron radiators), the Aquarea High
Temperature Solution is the most appropriate as
the Aquarea HT provides output water temperatures
of 65°C even at -15°C.
Aquarea HT is able to deliver hot water to 65°C
with the Heat Pump alone.
If the most important aspect is to keep nominal
heating capacities even at temperatures as low
as -7°C or -15, select the Aquarea T-CAP. This
ensures that there is always enough capacity to
heat the house without help from an external
boiler – even at extremely low temperatures.
Aquarea T-CAP always has high efficiency and
high heating capacity even at extremely low
temperatures. With Aquarea T-CAP, you can
always enjoy high savings.
AQUAREA T-CAP AND HIGH CONNECTIVITY COMPARISON
AQUAREA T-CAP MAINTAINS THE NOMINAL CAPACITY
TILL -15°C (EXAMPLE FOR 12KW)
AQUAREA T-CAP AND HIGH CONNECTIVITY HAVE EXTREMELY
HIGH EFFICIENCY EVEN AT -15°C
5
4,5
4
3,5
12
3
10
2,5
8
2
6
2,5
4
1
2
0,5
Aquarea T-CAP
COP is displayed
Aquarea High
connectivity
COP is displayed
0
0
+7ºC
-7ºC
-15ºC
+7ºC
-7ºC
-15ºC
* Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C; outside temperature: +7°C.
17
NEW AQUAREA 3 AND 5 KW BI-BLOC AND 6
AND 9 KW MONO-BLOC AIR TO WATER HEAT
PUMP MAXIMUM SAVINGS, MAXIMUM EFFICIENCY,
MINIMUM CO2 EMISSIONS, MINIMUM OF SPACE
NEW
2012
18
Panasonic has designed the new Aquarea Bi-bloc and Monobloc heat pumps for homes which have high performance
requirements.
Whatever the weather, Aquarea will always give you maximum
efficiency, even at -20°C! The New Aquarea is easy to install on
new or existing installations, in all types of properties.
AQUAREA
W
k
9
6/
,
5
/
W OMES
3
O
L
NEW FUOMRPTION H
S
CON
down to
-20ºC in
heating mode
OUTDOOR
TEMPERATURE
BI-BLOC APPLICATION
EXAMPLE LOW CONSUMPTION HOMES + SANITARY HOT WATER
COP COMPARISON (ELECTRICAL HEATER WITH
PANASONIC HEAT PUMP)
OUTSIDE
1kW
1kW
1kW
INSIDE HOUSE
4,41kW
MONO-BLOC APPLICATION
ELECTRICAL HEATER
PANASONIC HEAT PUMPS
EXAMPLE HEATING + SANITARY HOT WATER
POWER INPUT / ENERGY CONSUMPTION
POWER OUTPUT / HEATING CAPACITY (KW)
Sanitary tank
(200 l or 300 l)
* The comparison is made on nominal manufacturer values based on the following conditions. Rating
conditions: Heating: Inside air temperature: 20°C Dry Buld / Outside air temperature: 7°C Dry Bulb / 6°C Wet
Bulb. Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TECHNICAL BENEFITS
· Plug and play heating system
· No indoor box needed ( for 6 and 9 KW Monobloc)
· Extremely compact system
· 3 kW heater included
· High efficiency even at -20°C
OUTSIDE
TECHNICAL AREA
INSIDE HOUSE
EXAMPLE HEATING PLUG AND PLAY SYSTEM
TECHNICAL ELEMENTS
· Mono-bloc unit includes:
- Heat exchanger
- 3 speed hot water circulator
- 6-litre vessel
- Safety valve
- Pressure gauge
- 3 kW electrical heater
OUTSIDE
INSIDE HOUSE
19
+
HIT Photovoltaic solar panel
from Panasonic
20
HEAT PUMP + PHOTOVOLTAIC
PHOTOVOLTAIC SOLAR PANELS: THE
BEST SOLUTION FOR BIG SAVINGS
Panasonic Aquarea heat pumps can easily be
integrated with photovoltaic solar panels in order to
achieve maximum energy savings, cut fuel bills, and to
reduce C02 emissions.
AQUAREA
NEW
2012
Fan coil
(heating and cooling)
Radiator (heating)
Photovoltaic
solar panel
Floor heating,
panel heating
Hydraulic module
(water heat exchanger)
Outdoor unit
Hot water
Hot water storage tank
HOW DOES THE AQUAREA SYSTEM WORK ?
PHOTOVOLTAIC SOLAR PANELS FOR EVEN MORE SAVINGS
An air to water heat pump system uses heat energy present in the outdoor air
to heat the house, cool it and also to produce hot water. The Aquarea system
therefore uses free energy to heat or cool your home. It only consumes electricity
to operate the compressor, the electronics, the pumps and in the event of very
low temperatures, the electric elements. The result is very high efficiency and real
energy savings.
Combining photovoltaic solar panels with your heat pump can help to further
reduce your electrical consumption and CO2 emissions. Additionally, with
the unique HIT photovoltaic solar panel technology from Panasonic, you can
produce more electricity per square meter, helping you to increase your energy
savings still further.
SOLAR
Refrigerant
Reversible
heat pump
Example : with split-system
HWC
Water
Environmentally-Friendly Solar Cell
More Clean Energy. HIT can generate more clean Energy than other conventional
crystalline solar cells.
HWC
Hydraulic
module
HIT cell technology
The Panasonic HIT (Heterojunction with Intrinsic Thin layer) solar cell is made
of a thin mono crystalline silicon wafer surrounded by ultra-thin amorphous
silicon layers. This product provides the industry's leading performance and
value using state-of-the-art manufacturing techniques.
Radiators
Radiant floor
21
high
INVERTER+ COMPRESSOR FOR EVEN GREATER EFFICIENCY
efficiency
heating
Panasonic has clearly demonstrated it status as lead in this field with over 100 million compressors
supplied and the excellent quality and reliability of its heat pumps. With a Panasonic Inverter+ compressor,
you can save up to 30% energy compared to a traditional system with no inverter. With a Panasonic Inverter
compressor, the heat pump is always producing heat with the maximum of efficiency and adapting the
capacity to the element.
THE ADVANTAGES OF INVERTER AIR CONDITIONERS
Comparing Inverter and non-Inverter air conditioners.
HEAT IN THE
LIVING ROOM
(UNCOMFORTABLE)
COMFORT THE
LIVING ROOM
(COMFORTABLE)
COLD IN THE
LIVING ROOM
(UNCOMFORTABLE)
NO INVERTER
Slow to start. Takes longer to
reach the temperature set point.
22
INVERTER
Rapidly reaches the
desired temperature.
NO INVERTER
The temperature oscillates between the
two extremes and never stabilises. The
temperature falls and then rises
quickly, leading to a consumption peak.
INVERTER
Adjusts the temperature: more
comfort and greater savings.
Keeps the temperature
comfortable all the time.
AQUAREA
COP
4,74
COMFORT, SAVINGS AND POWER
EVEN AT VERY LOW TEMPERATURES
HEAT PUMPS: MORE EFFICIENT THAN OTHER HEATING
SYSTEMS
Panasonic’s inverter+ system
After quickly reaching the selected temperature, the Inverter+ system will gradually adjust
the power in order to maintain a constant temperature. Thus, there will not be any sudden
changes in temperature and the capacity of the power also guarantees a constant and
pleasant temperature, even when the outside temperature changes.
Maximum efficiency even at extremely low temperatures
The Aquarea range has been specially designed to provide maximum efficiency even at
extreme temperatures when compared with electrical heaters or gas boilers.
BEST EFFICIENCY COMPARED TO OTHER HEATING
EFFICIENCY SYSTEMS
SDF/SDC/MDF/MDC
Heating Capacity at +7°C (kW)
COP at +7°C with heating water temperature at 35°C
Heating Capacity at +2°C
COP at +2°C with heating water temperature at 35°C
Heating Capacity at -7°C (kW)
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C (kW)
COP at -15°C with heating water temperature at 35°C
SXF/SXC/MXF/MXC
Heating Capacity at +7°C (kW)
COP at +7°C with heating water temperature at 35°C
Heating Capacity at +2°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C (kW)
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C (kW)
COP at -15°C with heating water temperature at 35°C
7 kW
7
4,4
6,55
3,31
5,15
2,65
4,6
2,3
9 kW
9
4,74
9
3,53
9
2,81
9
2,54
9 kW
9
4,74
9
3,53
9
2,81
8,3
2,55
12kW
12
4,67
11,4
3,4
10
2,7
8,9
2,43
14 kW
14
4,5
12,4
3,32
10,7
2,62
9,5
2,35
Pan
Panasonic
heat pumps have a maximum COP of 4.74 at + 7°C which
makes them much more efficient than fossil fuel fired boilers, gas
mak
boilers
boil
l and electrical heaters.
16 kW
16
4,23
13
3,25
11,4
2,55
10,3
2,33
4,74
12 kW
12
4,67
12
3,4
12
2,7
12
2,4
Fuel fired boiler
Gas boiler
Aquarea
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C.
AQUAREA DESIGNER
Using Panasonic’s Aquarea Designer, projects can be developed simply and easily, by
either using the Quick Design or Expert Design options. Each allows the engineer to build
up the project data in a simple step-by-step process and choose to output reports (in
either Quick or Large formats) as HTML files or as print outs. To create the useful reports,
project data is input, including:
· Heated area
· Heating requirement
· Heating flow and return temperatures
· Climate data (from a simple drop-down menu) including outdoor design temperature
· Type of hot water tank, storage capacity and hot water target temperature.
Aquarea Designer will calculate the project’s energy costs in terms of hot water, heating
and pumping. It will show the equipment running times and calculate the Annual COP
(coefficient of performance). It then allows the designer to show clients a comparison with
other equipment options such as heating by conventional gas-fired boilers, oil systems,
wood, standard electric heating and electric night storage heaters. This compares running
costs, initial investment costs and maintenance costs. The comparison can also be made
for CO2 emissions and savings.
Available to download from www.panasonicproclub.com
23
WHAT MAKES THE AIR-TO-WATER HEAT
PUMP WORK
· The outdoor unit: this captures the free energy from the outdoor air and
brings it into the house by means of the hydraulic module. This free energy
are transported to the hydraulic module using an environmentally-friendly
refrigerant gas with a high thermal exchange coefficient (R407C).
· Via the hydraulic module, with control panel, the temperature inside the
house can be controlled and efficiency maximised. It has a heat exchanger
which transmits the energy contained in the refrigerant coming from the
outdoor unit to the water used for the home's heating and hot water.
The hydraulic module manages priorities in terms of heating and hot water
production.
This hydraulic module is situated inside the property in the case of the bibloc system or in the outdoor unit in the case of the mono-bloc system.
· The hot water cylinder heats the hot water. It is made of stainless steel, which
guarantees it a very long life. It is also fitted with a 3 kW element to ensure
maximum comfort when outdoor temperatures are very low. The heater, situated
at the top of the cylinder, guarantees maximum efficiency and faster heat-up.
24
A 3-way valve for the hot water cylinder connection is supplied with the hot
water cylinder.
· Other necessary or optional features (not provided by Panasonic):
- Room temperature thermostat, which can be connected to the Aquarea
system to ensure optimum room temperature conditions.
- Solar kit, to connect photovoltaic solar panels for even greater efficiency.
· A 3kW immersion heater is included within the hot water tank to ensure:
- Maximum comfort
- Maximum efficiency and more for ensure protection against the legionella
virus
TWO OR THREE EARTH LEAKAGE CUT-OUTS
The Aquarea hydraulic module has differential cut-off ensuring maximum safety
in the event of a short circuit:
- 2 differential cut-outs: 3 and 5 and 6 and 9 kW
- 3 differential cut-outs: 12, 14 and 16 kW
AQUAREA
THE CONTROL PANEL
EASY PROGRAMMING OF THE CONTROL PANEL
The control panel allows accurate temperature control based on the outdoor
temperature, providing maximum efficiency and comfort.
The control panel controls the heating temperature and the hot water cylinder
temperature very simply.
The primary circuit temperature is controlled based on the outdoor
temperature.
Who will adjust the control parameters through the remote control during the
commissioning of the system as is shown in the diagram below.
Your heating specialist must also select the type of operation you need:
heating priority or hot water cylinder priority.
THE HYDRAULIC MODULE
Heating feed R1 1/4
Water Temp.
OD(LO) = Setting Of Low Outdoor Ambient Temperature
OD(HI) = Setting Of High Outdoor Ambient Temperature
Heating return R1 1/4
Drainage
W(LO) = Setting Of High Water Temperature at Low outdoor air temperature
Wire inlet
W(HI) = Setting Of Low Water Temperature at High outdoor air temperature
Gas refrigerant
connection 5/8
Liquid refrigerant
connection 1/4 -3/8
W(HI)
W(LO)
OD(LO)
OD(HI)
Outdoor Temp.
Safety valve
Condenser
Interface card
EASY READING OF CONTROL OF WATER PRESSURE
10l Expansion tank
Overload protection
Flow controler
Pressure gauge
Connection plate
3-speed hot water
circulator
3 kW / 9 kW* Electric
element
Pressure gauge
The water pressure must be between 0.055
and 0.29 MPa
Refrigerated Links
connection with
outdoor unit
Water connection
* 3 kW for 7 and 9 kW, 6 kW for 12, 14, 16 kW single-phase
9 kW for 12, 14, 16 kW three-phase
25
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
By Intesis (www.intesis.com)
CONTROL YOUR HEAT PUMP WITH YOUR SMART
DEVICE -SMARTPHONE & INTERNETPanasonic has always offered its customers the most efficient Heat Pumps
and Air Conditioners. Now it has taken a step forward and presents with and
presents, in partnership with Intesis, the IntesisHome - the most advanced,
the most advanced service taking advantage of the latest Cloud Technology
to manage your climate system from anywhere in the world.
Control your environment from your iPad, iPhone, any Android device or from a PC with Internet
access using IntesisHome®. Offering the same functions as if you were at home: start/stop, Mode
Operation, Set Temperature, Room Temperature etc. Experience the new, advanced functionality
provided by IntesisHome® to achieve the best comfort and efficiency with the lowest energy
consumption.
26
SMART DEVICE
VIA SMARTPHONES &
INTERNET
INTE
IN
TERN
RNET
ET
VIA
VI
A SM
SMAR
ARTP
TPHO
HONE
NES
S&
SMAR
SM
ART
AR
T DE
DEVI
VICE
VI
CE
PUMP
PU
MP WIT
ITH
H TH
THE
E
CONT
CO
NTRO
NT
ROL
RO
L YO
YOUR
UR HEA
EAT
T
READY
iPHONE & ANDROID
NEW
AQUAREA
TAKE CONTROL FROM WHEREVER YOU ARE!
PC
iPhone
ANDROID
INTERNET
SERVICE IN THE CLOUD
STREET
OFFICE
INTERFACE
WIFI
WORK
GYM
AQUAREA
ROUTER WIFI
ADVANCED SERVICE HOSTED IN THE CLOUD THAT PROVIDES ACCESS FROM ANYWHERE TO YOUR AC SYSTEM.
FUNCTIONALITY
INSTALLATION
· Remote control: On/Off, Mode, Temp. Setting, etc.
· Scheduler calendar, Energy Saving functions, Preset configuration features
· Maintenance functions:
· Dirty Air Filter alerts
· Technical Service network
· Error list
· ECO advices.
· Multi-lingual application
· Easy installation.
· Videos and Manuals from www.intesishome.com
· Helpline (Phone & Internet).
· Automatic updates.
REFERENCE
· CZ-HI-Aquarea. IntesisHome for Aquarea
27
CONNECTIVITY
GREAT FLEXIBILITY FOR INTEGRATION INTO YOUR
KNX / ENOCEAN / MODBUS PROJECTS ALLOWS FULLY
BI-DIRECTIONAL MONITORING AND CONTROL
OF ALL THE FUNCTIONING PARAMETERS
The Intesis interface has been designed specifically for Panasonic and provides
complete monitoring, control and full functionality of the entire Aquarea line-up
from KNX, EnOcean and Modbus installations.
Interfaces must purchased at Intesis.
More information on www.intesis.com
To know more about compatibility of Panasonic Heat pumps with Intesis interfaces,
please visit: http://www.intesis.com/pdf/IntesisBox_PA-AC-xxx-1_AC_Compatibility.pdf
28
AQUAREA
INTERFACE TO CONNECT AQUAREA TO KNX
INTESIS PART Nº: PA-AW-KNX-1i
Intesis new Aquarea-KNX interface allows monitoring and control, fully
bi-directionally, all the functioning parameters of Aquarea control from KNX
installations.
· Small dimensions.
· Quick installation and possibility of hidden installation.
· External power not required.
· Direct connection to the unit.
· Fully KNX interoperable. Control and monitoring, from sensors or gateways, of
the internal variables of the indoor unit and error codes and indication.
· Aquarea unit can be controlled simultaneously by the remote control of the
Aquarea unit and by KNX devices.
· 4 Binary inputs, they work as standard KNX Binary Inputs (On/Off, Send value,
Lights, Blinds, etc) as well as being used to control the Aquarea unit directly.
· Manual of installation: www.intesis.com
4 x binary inputs
PA-AC-KNX-1i
Any standar KNX
device
INTERFACE TO CONNECT AQUAREA TO ENOCEAN
INTESIS PART Nº: PA-AW-ENO-1i / PA-AW-ENO-1iC
Intesis new Aquarea-EnOcean PA-AW-ENO-1i interface allows monitoring and
control, fully bi-directionally, all the functioning parameters of the Aquarea
control from EnOcean installations.
· Small dimensions.
· Quick installation.
· External power not required.
· Direct connection to the Aquarea unit using the same parameters as on the
control.
· Fully EnOcean interoperable. Control and monitoring, from sensors or
gateways, of the internal variables of the indoor unit and error codes and
indication.
· Aquarea unit can be controlled simultaneously by the remote control of the
Aquarea unit and by EnOcean devices.
· 4 binary inputs. They work as standard EnOcean binary inputs as well as
being used to control the Aquarea unit directly.
·Manual of installation: www.intesis.com
4 x binary inputs
PA-AC-ENO-1i
PA-AC-ENO-1iC
EnOcean
Switch
EnOcean
RC
Keycard
Movement
sensor
INTERFACE TO CONNECT AQUAREA TO MODBUS
INTESIS PART Nº: PA-AW-MBS-1
Intesis new Aquarea-Modbus RTU Slave interface allows monitoring and control,
fully bi-directionally, all the functioning parameters of Aquarea control from
Modbus installations.
· Small dimensions.
· Quick installation and possibility of hidden installation.
· External power not required.
· Direct connection to the unit.
· Fully Modbus interoperable. Control and monitoring, from any BMS or PLC
Modbus Master, of internal variables of the indoor unit and error codes and
indication.
· Aquarea unit can be controlled simultaneously by the remote control of the
Aquarea unit and by Modbus Master device.
·Manual of installation: www.intesis.com
PA-AW-MBS-1
MODBUS
Building Management System
29
HP BI-BLOC APPLICATION EXAMPLES
HP BI-BLOC + RADIATORS
HP BI-BLOC + BOILER + RADIATORS + FAN COILS + SOLAR KIT
HP BI-BLOC + ACS + BOILER + RADIATORS
HP BI-BLOC + ACS+ BUFFER TANK + RADIATORS + FLOOR HEATING +
SOLAR KIT
HP BI-BLOC + ACS+ RADIATORS
HP BI-BLOC + RADIATORS + BUFFER TANK + FLOOR HEATING
HP BIBLOC + ACS + BUFFER TANK +FAN COIL + FLOOR HEATING +
RADIATORS
HP BI-BLOC 3 AND 5 KW .LOW CONSUMPTION + SANITARY HOT WATER
+ BUFFER TANK + RADIATORS + FLOOR HEATING
30
AQUAREA
HP MONO-BLOC APPLICATION EXAMPLES
HP MONO-BLOC + BUFFER TANK + BOILER + RADIATORS +
SWIMMING POOL
HP MONO-BLOC + BI-BLOC + ACS + RADIATORS + FLOOR HEATING
HP MONO-BLOC + BUFFER TANK + ACS +BOILER + RADIATORS +
SWIMMING POOL
HP MONO-BLOC 6 AND 9 KW .EASY TO INSTALL, WITHOUT ANY BOX
INSIDE THE HOUSE + BUFFER TANK + ACS + FLOOR HEATING
HP MONO BLOC + BUFFER TANK + ACS +
BOILER + RADIATORS
HP MONO-BLOC 6 AND 9 KW .EASY TO INSTALL, WITHOUT ANY BOX
INSIDE THE HOUSE + RADIATORS + FLOOR HEATING
31
AQUAREA LINE-UP!
NEW
2012
FIGURE 1 (F1)
FIGURE 3 (F3)
FIGURE 2 (F2)
NEW
2012
FIGURE 4 (F4)
FIGURE 5 (F5)
LINE UP
Aquarea High Connectivity
Bi-Bloc
Single phase
Heating only
Heating and cooling
Three phase
3KW
5KW
WH-SDF03E3E5* (F1)
WH-UD03EE5
WH-SDF05E3E5* (F1)
W
WH-UD05EE5
W
WH-SDC03E3E5*
WH-UD03EE5
NEW
2012
(F1)
N W
NEW
2012
WH-SDC05E3E5*
W
WH-UD05EE5
W
6KW
7KW
WH-SDF07C3E5
WH-UD07CE5-A (F2)
NEW
2012
(F1)
WH-SDC07C3E5
WH-UD07CE5-A (F2)
N W
NEW
2012
Heating only
Heating and cooling
Mono-Bloc
Single phase
Heating only
WH-MDF06D3E5 (F5)
Heating and cooling
WH-MDC06E3E5 ** (F5) NEW
NEW
2012
2012
Three phase
Heating only
Heating and cooling
Aquarea T-CAP
Bi-Bloc
Single phase
Heating only
Heating and cooling
Three phase
Heating only
Heating and cooling
Mono-Bloc
Single phase
Heating only
Heating and cooling
Three phase
Heating only
Heating and cooling
Aquarea High temperature
Bi-Bloc
Single phase
Heating only
Three phase
Heating only
Single phase
Heating only
Three phase
Heating only
VRF ECOi + Water
Heat Exchanger
Three phase
Heating and cooling
GAS VRF ECOg +
Water Heat
Exchanger
Three phase
Gas. Heating and
cooling
Mono-Bloc
AQUAREA PRO
Low connectivity : control of 3 way valve, tank heater On/Off signal, tank thermostat signal reception, On/Off from external control, weekly timer
High connectivity : Low connectivity + solar pannels connection, room thermostat connection
32
AQUAREA
NEW
NEW
2012
2012
FIGURE 6 (F6)
9KW
12KW
14KW
16KW
WH-SDF09C3E5
WH-UD09CE5-A (F2)
WH-SDF12C6E5
WH-UD12CE5-A (F3)
WH-SDF14C6E5
WH-UD14CE5-A (F3)
WH-SDF16C6E5
WH-UD16CE5-A (F3)
WH-SDC09C3E5
WH-UD09CE5-A (F2)
WH-SDC12C6E5
WH-UD12CE5-A (F3)
WH-SDC14C6E5
WH-UD14CE5-A (F3)
WH-SDC16C6E5
WH-UD16CE5-A (F3)
WH-SDF09C3E8
WH-UD09CE8 (F3)
WH-SDF12C9E8
WH-UD12CE8 (F3)
WH-SDF14C9E8
WH-UD14CE8 (F3)
WH-SDF16C9E8
WH-UD16CE8 (F3)
WH-SDC09C3E8
WH-UD09CE8 (F3)
WH-SDC12C9E8
WH-UD12CE8 (F3)
WH-SDC14C9E8
WH-UD14CE8 (F3)
WH-SDC16C9E8
WH-UD16CE8 (F3)
WH-MDF12C6E5 (F4)
WH-MDF14C6E5 (F4)
WH-MDF16C6E5 (F4)
WH-MDC09C3E5 (F4) NEW
WH-MDC09E3E5** (F5) 2012
WH-MDC12C6E5 (F4)
WH-MDC14C6E5 (F4)
WH-MDC16C6E5 (F4)
WH-MDF09C3E8 (F4)
WH-MDF12C9E8 (F4)
WH-MDF14C9E8 (F4)
WH-MDF16C9E8 (F4)
WH-MDC09C3E8 (F4)
WH-MDC12C9E8 (F4)
WH-MDC14C9E8 (F4)
WH-MDC16C9E8 (F4)
WH-MDF09C3E5 (F4)
WH-MDF09D3E5 (F5)
WH-SXF09D3E5
WH-UX09DE5 (F2)
NEW
WH-SXF12D6E5
WH-UX12DE5 (F3)
NEW
WH-SXC09D3E5
WH-UX09DE5 (F2)
WH-SXC12D6E5
WH-UX12DE5 (F3)
N W
NEW
WH-SXF09D3E8
WH-UX09DE8 (F3)
WH-SXF12D9E8
WH-UX12DE8 (F3)
NEW
WH-SXC12D9E8
WH-UX12DE8 (F3)
N W
NEW
2012
NEW
2012
N W
NEW
2012
WH-MXF09D3E5 (F4)
NEW
2012
2012
WH-MXF12D6E5 (F4)4) NEW
N W
NEW
2012
WH-MXC12D6E5 (F4)4) NEW
N W
NEW
2012
WH-MXF12D9E8 (F4)4) NEW
2012
WH-MXC09D3E8
(F4)
NEW
2012
WH-MXC12D9E8 (F4)4)
2012
WH-SHF09D3E5
WH-UH09DE5 (F3)
N W
NEW
2012
WH-SHF09D3E8
WH-UH09DE8 (F3)
N W
NEW
2012
WH-MHF09D3E5
(F4)
WH-MHF09D3E8
(F4)
71 kW
2012
2012
WH-MXF09D3E8 (F4)
50KW
2012
2012
WH-MXC09D3E5 (F4)
28KW
2012
NEW
WH-SXC09D3E8
WH-UX09DE8 (F3)
FIGURE 7 (F7)
NEW
2012
WH-SHF12D6E5
WH-UH12DE5 (F3)
N W
NEW
2012
WH-SHF12D9E8
WH-UH12DE8 (F3)
N W
NEW
2012
WH-MHF12D6E5
(F4)
4)
WH-MHF12D9E8
(F4)
4)
NEW
2012
NEW
2012
NEW
2012
NEW
2012
S-250WX2E5 (F6) NEW
S-500WX2E5 (F6)
2012
S-250WX2E5
(F6)
NEW
2012
NEW
2012
S-500WX2E5
(F6)
NEW
2012
S-710WX2E5 (F7)
NEW
2012
** Avaiable in November 2012
33
4.62 COP
high
efficiency
AQUAREA
HIGH CONNECTIVITY
HIGH
H CON
CON
CO
NNECT
CTIVIT
CTIVIT
IVITY
Y
AQUA
AQUA
QUAREA
REA
RE
EA
A
efficiency
high
4.62 COP
BI-BLOC // HIGH CONNECTIVITY // 3 AND 5 KW AQUAREA //
HEATING ONLY - SDF // HEATING AND COOLING - SDC
The new 3 kW and 5 kW Aquarea heat pump from Panasonic is specially design specially designed for low
energy homes.
Thanks to the system's high degree of technology and advanced control, they are able to maintain a high
capacity and efficiency event at -7°C and -15°C.
The very compact outdoor unit makes the installation very easy.
Whatever the weather, Aquarea will always give you maximum efficiency, even at -20 ºC.
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
heating mode
5 year
compressor
warranty
OUTDOOR
TEMPERATURE
OPTIONAL
BI-BLOC // MINI T-CAP // HEATING ONLY // HEATING AND COOLING // SDC
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35°C
Cooling capacity at 35°C
EER at 35°C with cooling water temperature at 7/12°C
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
kW
kW
kW
mm
kg
No. of Speed
Input Power(max)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Liquid
Gas
Refrigerant (R410A)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R410A)
I/D&O/D Hight Difference
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
SINGLE-PHASE HEATING AND COOLING
WH-SDC03D3E5*
WH-SDC05D3E5*
3
4,62
3
2,7
-
5
4,5
5
2,8
4,5
2,90
892 x 502 x 353
50
5
4,5
4,2
2,5
-
-
892 x 502 x 353
50
892 x 502 x 353
50
3
4,62
3
2,7
3
2,97
892 x 502 x 353
50
WH-UD03EE5
47
WH-UD05EE5
WH-UD03EE5
WH-UD05EE5
48
47
48
618 x 833 x 301
38
12,70 (1/2")
6,35 (1/4")
618 x 833 x 301
38
12,70 (1/2")
6,35 (1/4")
618 x 833 x 301
38
12,70 (1/2")
6,35 (1/4")
618 x 833 x 301
38
12,70 (1/2")
6,35 (1/4")
5 – 15
5 – 15
5 – 15
5 – 15
5
–20 to 35
25 – 55 / 5 – 20
5
–20 to 35
25 – 55 / 5 – 20
5
–20 to 35
25 – 55 / 5 – 20
5
–20 to 35
25 – 55 / 5 – 20
W
l/min
kW
kW
Running and starting Current
Maximum Current
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
SINGLE-PHASE HEATING ONLY
WH-SDF03D3E5*
WH-SDF05D3E5*
A
A
dB(A)
dB
mm
kg
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
* Available in September, Preliminary specifications
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
34
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
AQUAREA
NEW
2011-2012
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH
INTENSISHOME® DEVICE
· NEW! RANGE FROM 3 AND 5 KW, SINGLE-PHASE, HEATING ONLY
AND HEATING AND COOLING
· MAXIMUM OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· EASY AND FAST TO INSTALL
ENERGY AND ENVIRONMENTAL EFFICIENCY
· Super efficient even at outdoor temperatures as low as -15°C
· Maximum COP of 4,62
· Environmentally-friendly refrigerant gas R410A
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Wired control panel for installation in the house
· Easy programming on the control panel
· Ipad/Android ready with the IntesisHome box (optional)
EASY INSTALLATION AND MAINTENANCE
· Outdoor unit easy to open for maintenance
. Expansion vessel included
WH-UD03EE5
WH-UD05EE5
WH-TD20E3E5
WH-TD30E3E5
35
4.41* COP
high
efficiency
AQUAREA
HIGH CONNECTIVITY
HI
HIGH
CON
NNECT
N
IVITY
AQ
A
AQUAR
AQUA
QUA
UAREA
REA
A
efficiency
high
4.74* COP
AQUAREA MDF & MDC // MONO-BLOC // HIGH CONNECTIVITY // 6 AND 9 KW
AQUAREA // HEATING AND COOLING // SINGLE-PHASE
Panasonic has designed the new Aquarea Mono-bloc heat pump for houses which have high performance
requirements but limited space to install the outdoor unit.
Whatever the weather, Aquarea will always give you maximum efficiency, even at -20 ºC. The Mono-bloc is easy
to install on new or existing installations, in all type of houses.
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
heating mode
5 year
compressor
warranty
OUTDOOR
TEMPERATURE
OPTIONAL
MONO-BLOC // 6 AND 9 KW AQUAREA // HEATING // MDF & MDC
SINGLE-PHASE
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at +2°C
COP at +2°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Cooling capacity at 35°C
EER at 35°C with cooling water temperature at 7/12°C
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
kW
kW
kW
kW
kW
dB(A)
dB
mm
kg
No. of Speed
Water Flow (ΔT=5 K. 35°C)
Input Power
Capacity of integrated electric heater
Input Power at +7°C
Running and starting Current at +7°C
Maximum Current
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15)
l/min
W
kW
kW
A
A
°C
°C
WH-MDF06D3E5
WH-MDF09D3E5
WH-MDC06E3E5*
WH-MDC09E3E5*
6
4.41
5
3.4
5.15
2.65
5.9
2.2
47
65
865 x 1283 x 320
112
R 1-3/16
3
17.2
75
3.0
1.36
6.2
20.5
-20 to 35
25 – 55
9
4.10
7
3
7.45
3.10
7.6
2.0
49
67
865 x 1283 x 320
112
R 1-3/16
3
25.8
75
3.0
2.2
10.1
22.9
-20 to 35
25 – 55
6
4.41
5
3.4
5.15
2.65
5.9
2.2
5.5
2.71
47
65
865 x 1283 x 320
112
R 1-3/16
3
17.2
75
3.0
1.36
6.2
20.5
-20 to 35
25 – 55
9
4.10
7
3
7.45
3.10
7.6
2.0
7.0
2.41
49
67
865 x 1283 x 320
112
R 1-3/16
3
25.8
75
3.0
2.2
10.1
22.9
-20 to 35
25 – 55
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
* Preliminary specifications
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
36
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
AQUAREA
NEW
2011-2012
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· NEW! RANGE FROM 6 AND 9 KW, SINGLE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· PLUG AND PLAY SYSTEM
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4,41
· Environmentally-friendly refrigerant gas R410A
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Single-unit range, with no refrigerant connections
· Wired control panel for installation in the house
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Outdoor unit easy to open for maintenance
WH-MDF06D3E5
WH-MDF09D3E5
WH-MDF06E3E5
WH-MDF09E3E5
WH-TD20E3E5
WH-TD30E3E5
37
4.74* COP
high
efficiency
AQUAREA
HIGH CONNECTIVITY
HI
HIGH
CON
NNECT
N
IVITY
AQ
A
AQUAR
AQUA
QUA
UAREA
REA
A
efficiency
high
4.74* COP
AQUAREA SDF // BI-BLOC // HIGH CONNECTIVITY // HEATING ONLY
SINGLE-PHASE // THREE-PHASE
The Aquarea SDF range adapts equally well to an existing installation such as a boiler backup or to a new
installation with underfloor heating, low-temperature radiators or even fan-coil heaters. This range can also be
connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is
possible to connect a thermostat for even better heating control and management.
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
down to
friendly
efficiency
heating
-20ºC in
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
R410A
domestic
solar
hot
panels
connection
RETROFIT
water
SOLAR KIT
5 year
compressor
warranty
DHW
OPTIONAL
BI-BLOC // HIGH-CONNECTIVITY // HEATING ONLY // SDF
SINGLE-PHASE
THREE-PHASE
WH-SDF07C3E5 WH-SDF09C3E5 WH-SDF12C6E5 WH-SDF14C6E5 WH-SDF16C6E5 WH-SDF09C3E8 WH-SDF12C9E8 WH-SDF14C9E8 WH-SDF16C9E8
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35 °C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Running and starting Current
Maximum Current
kW
W
l/min
kW
kW
A
A
7
4,4
5,15
2,65
4,6
2,3
892 x 502 x 353
43
R1 1/4
3
100
20,1
3
1,59
7,3
21
WH-UD07CE5-A WH-UD09CE5-A WH-UD12CE5-A WH-UD14CE5-A WH-UD16CE5-A WH-UD09CE8
WH-UD12CE8
WH-UD14CE8
WH-UD16CE8
dB(A)
dB
mm
KG
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
48
66
795 x 900 x 320
66
6,35 (1/4")
15,88 (5/8")
1,45
3 – 30
7
10
30
20
–20 to 35
25 – 55
50
67
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55
51
68
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55
53
70
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,95
3 – 40
7
30
50
30
–20 to 35
25 – 55
kW
kW
mm
kg
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
Liquid
Gas
Refrigerant (R410A)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R410A)
I/D&O/D Hight Difference
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
9
4,10
5,9
2,5
5,9
2,2
892 x 502 x 353
43
R1 1/4
3
100
25,8
3
2,2
10,1
22,9
49
67
795 x 900 x 320
66
6,35 (1/4")
15,88 (5/8")
1,45
3 – 30
7
10
30
20
–20 to 35
25 – 55
12
4,67
10
2,7
8,9
2,43
892 x 502 x 353
49
R1 1/4
3
190
34,4
6
2,57
11,7
24
50
67
1340 x 900 x 320
106
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55
14
4,5
10,7
2,62
9,5
2,35
892 x 502 x 353
49
R1 1/4
3
190
40,1
6
3,11
14,1
25
51
68
1340 x 900 x 320
106
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55
16
4,23
11,4
2,55
10,3
2,33
892 x 502 x 353
49
R1 1/4
3
190
45,9
6
3,78
17,1
26
53
70
1340 x 900 x 320
106
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55
9
4,74
9
2,81
8,3
2,55
892 x 502 x 353
50
R1 1/4
3
190
25,8
3
1,9
2,9
7,5
12
4,67
10
2,7
8,9
2,43
892 x 502 x 353
51
R1 1/4
3
190
34,4
9
2,57
3,9
8,8
14
4,5
10,7
2,62
9,5
2,35
892 x 502 x 353
51
R1 1/4
3
190
40,1
9
3,11
4,7
9,4
16
4,23
11,4
2,55
10,3
2,33
892 x 502 x 353
51
R1 1/4
3
190
45,9
9
3,78
5,7
9,9
49
66
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
38
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
AQUAREA
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 7 TO 16 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· MAXIMUM 40 m RISE BETWEEN THE OUTDOOR UNIT AND THE
HYDRAULIC MODULE
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
· Environmentally-friendly refrigerant gas R410A
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Control on the hydraulic module
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Easy-to-access pressure gauge for easy control of the water pressure
· Easy-to-open hydraulic module and outdoor unit
WH-UD07CE5-A
WH-UD09CE5-A
WH-UD09CE8
WH-UD12CE5-A
WH-UD14CE5-A
WH-UD16CE5-A
WH-UD12CE8
WH-UD14CE8
WH-UD16CE8
WH-TD20E3E5
WH-TD30E3E5
39
4.74* COP
high
efficiency
AQUAREA
HIGH CONNECTIVITY
HI
HIGH
CON
NNECT
N
IVITY
AQ
A
AQUAR
AQUA
QUA
UAREA
REA
A
efficiency
high
4.74* COP
AQUAREA SDC // BI-BLOC // HIGH CONNECTIVITY // HEATING AND COOLING
SINGLE-PHASE // THREE-PHASE
The Aquarea SDC range adapts equally well to an existing installation such as a boiler backup or to a new
installation with underfloor heating, low-temperature radiators or even fan-coil heaters. This range can also be
connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is
possible to connect a thermostat for even better heating and cooling control and management.
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
down to
friendly
efficiency
heating
-20ºC in
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
R410A
RETROFIT
domestic
solar
hot
panels
connection
water
SOLAR KIT
5 year
compressor
warranty
DHW
OPTIONAL
BI-BLOC // HIGH-CONNECTIVITY // HEATING AND COOLING // SDC
SINGLE-PHASE
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Cooling capacity at 35°C
EER at 35°C with cooling water temperature at 7/12°C
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power (Input power H/C)
Running and starting Current
Maximum Current
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
Liquid
Gas
Refrigerant (R410A)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R410A)
I/D&O/D Hight Difference
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
WH-SDC07C3E5
kW
7
4,4
kW
5,15
2,65
kW
4,6
2,3
6
2,2
mm
892 x 502 x 353
kg
45
R1 1/4
3
W
75
l/min
20,1
kW
3
kW
1,59 / 2,30
A
7,30 / 10,40
A
21
WH-UD07CE5-A
dB(A)
48
dB
66
mm
795 x 900 x 320
KG
66
mm (Inch) 6,35 (1/4")
mm (Inch) 15,88 (5/8")
kg
1,45
m
3 – 30
m
7
m
10
g/m
30
m
20
°C
–20 to 35
°C
25 – 55 / 5 – 20
THREE-PHASE
WH-SDC09C3E5
9
4,09
5,9
2,5
5,9
2,2
7
2,1
892 x 502 x 353
45
R1 1/4
3
75
25,8
3
2,2 / 2,9
10,1 / 13,1
22,9
WH-UD09CE5-A
49
67
795 x 900 x 320
66
6,35 (1/4")
15,88 (5/8")
1,45
3 – 30
7
10
30
20
–20 to 35
25 – 55 / 5 – 20
WH-SDC12C6E5
12
4,67
10
2,7
8,9
2,43
10
2,39
892 x 502 x 353
51
R1 1/4
3
190
34,4
6
2,57 / 3,6
11,7 / 16,1
24
WH-UD12CE5-A
50
67
1340 x 900 x 320
106
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
WH-SDC14C6E5
14
4,5
10,7
2,62
9,5
2,35
11,5
2,24
892 x 502 x 353
51
R1 1/4
3
190
40,1
6
3,11 / 4,4
14,1 / 19,7
25
WH-UD14CE5-A
51
68
1340 x 900 x 320
106
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
WH-SDC16C6E5
16
4,23
11,4
2,55
10,3
2,33
12,2
2,19
892 x 502 x 353
51
R1 1/4
3
190
45,9
6
3,78 / 4,8
17,1 / 21,5
26
WH-UD16CE5-A
53
70
1340 x 900 x 320
106
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
WH-SDC09C9E8
9
4,74
9
2,81
8,3
2,55
7
2,68
892 x 502 x 353
51
R1 1/4
3
190
25,8
3
1,9 / 2,25
2,9 / 3,4
7,5
WH-UD09CE8
49
66
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
WH-SDC12C9E8
12
4,67
10
2,7
8,9
2,43
10
2,42
892 x 502 x 353
52
R1 1/4
3
190
34,4
9
2,57 / 3,55
3,9 / 5,3
8,8
WH-UD12CE8
50
67
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
WH-SDC14C9E8
14
4,5
10,7
2,62
9,5
2,35
11,5
2,25
892 x 502 x 353
52
R1 1/4
3
190
40,1
9
3,11 / 4,4
4,7 / 6,6
9,4
WH-UD14CE8
51
68
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,75
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
WH-SDC16C9E8
16
4,23
11,4
2,55
10,3
2,33
12,2
2,19
892 x 502 x 353
52
R1 1/4
3
190
45,9
9
3,78 /4,8
5,7 / 7,2
9,9
WH-UD16CE8
53
70
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
2,95
3 – 40
7
30
50
30
–20 to 35
25 – 55 / 5 – 20
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
40
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
AQUAREA
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 7 TO 16 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· MAXIMUM 40 m RISE BETWEEN THE OUTDOOR UNIT AND THE
HYDRAULIC MODULE
· COOLING TEMPERATURE RANGE 5–20 °C
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
· Environmentally-friendly refrigerant gas R410A
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Control on the hydraulic module
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Easy-to-access pressure gauge for easy control of the water pressure
· Easy-to-open hydraulic module and outdoor unit
WH-UD07CE5-A
WH-UD09CE5-A
WH-UD09CE8
WH-UD12CE5-A
WH-UD14CE5-A
WH-UD16CE5-A
WH-UD12CE8
WH-UD14CE8
WH-UD16CE8
WH-TD20E3E5
WH-TD30E3E5
41
4.74* COP
high
efficiency
AQUAREA
HIGH CONNECTIVITY
HI
HIGH
CON
NNECT
N
IVITY
AQ
A
AQUAR
AQUA
QUA
UAREA
REA
A
efficiency
high
4.74* COP
AQUAREA MDF // MONO-BLOC // HIGH CONNECTIVITY // HEATING ONLY
SINGLE-PHASE // THREE-PHASE
The Aquarea MDF range adapts equally well to an existing installation such as a boiler backup or to a
new installation with underfloor heating, low-temperature radiators or even fan-coil heaters. This range
can also be connected to a solar kit in order to increase efficiency and minimize the impact on the
ecosystem. Finally, it is possible to connect a thermostat for even better heating control and
management.
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
solar
domestic
panels
connection
SOLAR KIT
hot
water
5 year
compressor
warranty
DHW
OPTIONAL
MONO-BLOC // HIGH-CONNECTIVITY // HEATING ONLY // MDF
SINGLE-PHASE
OUTDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35 °C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (^aT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
WH-MDF09C3E5
kW
9
4,74
kW
9
2,81
kW
8,3
2,55
dB(A) 49
dB
66
mm 1410 x 1283 x 320
kg
153
R1¼
3
W
190
l/min 25,8
kW
3
kW
1,9
A
8,7
A
22,9
°C
–20 to 35
°C
25 – 55
THREE-PHASE
WH-MDF12C6E5
12
4,67
10
2,7
8,9
2,43
50
67
1410 x 1283 x 320
153
R1¼
3
190
34,4
6
2,57
11,6
24
–20 to 35
25 – 55
WH-MDF14C6E5
14
4,5
10,7
2,62
9,5
2,35
51
68
1410 x 1283 x 320
153
R1¼
3
190
40,1
6
3,11
14,1
25
–20 to 35
25 – 55
WH-MDF16C6E5
16
4,23
11,4
2,55
10,3
2,33
53
70
1410 x 1283 x 320
153
R1¼
3
190
45,9
6
3,78
17,1
26
–20 to 35
25 – 55
WH-MDF09C3E8
9
4,74
9
2,81
8,3
2,55
49
66
1410 x 1283 x 320
157
R1¼
3
190
25,8
3
1,9
2,9
7,5
–20 to 35
25 – 55
WH-MDF12C9E8
12
4,67
10
2,7
8,9
2,43
50
67
1410 x 1283 x 320
157
R1¼
3
190
34,4
9
2,57
3,9
8,8
–20 to 35
25 – 55
WH-MDF14C9E8
14
4,5
10,7
2,62
9,5
2,35
51
68
1410 x 1283 x 320
157
R1¼
3
190
40,1
9
3,11
4,7
9,4
–20 to 35
25 – 55
WH-MDF16C9E8
16
4,23
11,4
2,55
10,3
2,33
53
70
1410 x 1283 x 320
157
R1¼
3
190
45,9
9
3,78
5,7
9,9
–20 to 35
25 – 55
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
* Tentative specifications
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
42
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
AQUAREA
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 16 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised according to the return water temperature
· Autonomous management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Single-unit range, with no refrigerant connections
· Wired control panel for installation in the house
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Outdoor unit easy to open for maintenance
WH-TD20E3E5
WH-TD30E3E5
43
4.74* COP
high
efficiency
AQUAREA
HIGH CONNECTIVITY
HI
HIGH
CON
NNECT
N
IVITY
AQ
A
AQUAR
AQUA
QUA
UAREA
REA
A
efficiency
high
4.74* COP
AQUAREA MDC // MONO-BLOC // HIGH CONNECTIVITY //
HEATING AND COOLING SINGLE-PHASE // THREE-PHASE
The Aquarea MDC range adapts equally well to an existing installation such as a boiler backup or to a new
installation with floor heating, low-temperature radiators or even fan-coil heaters. This range can also be
connected to a solar kit in order to increase efficiency and minimize the impact on the ecosystem. Finally, it is
possible to connect a thermostat for even better heating and cooling control and management.
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
solar
domestic
panels
connection
SOLAR KIT
hot
water
5 year
compressor
warranty
DHW
OPTIONAL
MONO-BLOC // HIGH-CONNECTIVITY // HEATING AND COOLING // MDC
SINGLE-PHASE
OUTDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Cooling capacity at 35°C
EER at 35°C with cooling water temperature at 7/12°C
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (^aT=5 K. 35°C)
Capacity of integrated electric heater
Input Power (Input Power H/C)
Starting Current (Input Power H/C)
Maximum Current
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
kW
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
°C
°C
WH-MDC09C3E5
9
4,74
9
2,81
8,3
2,55
7
2,68
49
66
1410 x 1283 x 320
153
R1¼
3
190
25,8
3
1,9 / 2,25
8,7 / 10,2
22,9
–20 to 35
22 - 55 / 5 - 20
THREE-PHASE
WH-MDC12C6E5
12
4,67
10
2,7
8,9
2,43
10
2,39
50
67
1410 x 1283 x 320
153
R1¼
3
190
34,4
6
2,57 / 3,6
11,6 / 16,1
24
–20 to 35
22 - 55 / 5 - 20
WH-MDC14C6E5
14
4,5
10,7
2,62
9,5
2,35
11,5
2,25
51
68
1410 x 1283 x 320
153
R1¼
3
190
40,1
6
3,11 / 4,4
14,1 / 19,7
25
–20 to 35
22 - 55 / 5 - 20
WH-MDC16C6E5
16
4,23
11,4
2,55
10,3
2,33
12,2
2,19
53
70
1410 x 1283 x 320
153
R1¼
3
190
45,9
6
3,78 / 4,8
17,1 / 21,5
26
–20 to 35
22 - 55 / 5 - 20
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
44
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
WH-MDC09C3E8
9
4,74
9
2,81
8,3
2,55
7
2,68
49
66
1410 x 1283 x 320
157
R1¼
3
190
25,8
3
1,9 / 2,25
2,9 / 3,4
7,5
–20 to 35
22 - 55 / 5 - 20
WH-MDC12C9E8
12
4,67
10
2,7
8,9
2,43
10
2,39
50
67
1410 x 1283 x 320
157
R1¼
3
190
34,4
9
2,57 / 3,6
3,9 / 5,3
8,8
–20 to 35
22 - 55 / 5 - 20
WH-MDC14C9E8
14
4,5
10,7
2,62
9,5
2,35
11,5
2,25
51
68
1410 x 1283 x 320
157
R1¼
3
190
40,1
9
3,11 / 4,4
4,7 / 6,6
9,4
–20 to 35
22 - 55 / 5 - 20
WH-MDC16C9E8
16
4,23
11,4
2,55
10,3
2,33
12,2
2,19
53
70
1410 x 1283 x 320
157
R1¼
3
190
45,9
9
3,78 / 4,8
5,7 / 7,2
9,9
–20 to 35
22 - 55 / 5 - 20
AQUAREA
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 16 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· COOLING TEMPERATURE RANGE 5–20 °C
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised according to the return water temperature
· Autonomous management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Single-unit range, with no refrigerant connections
· Wired control panel for installation in the house
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Outdoor unit easy to open for maintenance
WH-TD20E3E5
WH-TD30E3E5
45
100%
capacity
at -15°C
AQUAREA T-CAP
AQUA
QUAREA T
T-CA
CAP
CA
at -15°C
capacity
100%
NEW
iPHONE & ANDROID
READY
AQUAREA SXF // BI-BLOC // T-CAP // HEATING ONLY
SINGLE-PHASE // THREE-PHASE
The Aquarea SXF is the new Aquarea product from Panasonic for central heating. T-CAP stands for Total capacity as
this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster
heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water
temperature.
The new SXF is ideal for houses where maintaining the same capacity is important such as new houses or
houses without support from an external boiler.
The SXF can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating,
low-temperature radiators or even fan-coil heaters. This Range can also be connected to a solar kit in order to
increase efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even
better heating control and management.
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
solar
panels
connection
SOLAR KIT
domestic
hot
water
5 year
compressor
warranty
DHW
OPTIONAL
BI-BLOC // AQUAREA T-CAP // HEATING ONLY // SXF
SINGLE-PHASE
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35 °C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
Liquid
Gas
Refrigerant (R410A)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R410A)
I/D&O/D Hight Difference
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
kW
kW
kW
mm
kg
W
l/min
kW
kW
A
A
dB(A)
dB
mm
KG
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
WH-SXF09D3E5
9
4,74
9
2,81
9
2,54
892 x 502 x 353
47
R1¼
3
190
25,8
3
1,9
8,8
25
WH-UX09DE5
49
66
1340 x 900 x 320
107
9,52 (3/8")
15,88 (5/8")
3,10
3 – 30
7
15
50
20
–20 to 35
25 – 55
THREE-PHASE
WH-SXF12D6E5
12
4,67
12
2,7
12
2,4
892 x 502 x 353
49
R1¼
3
190
34,4
3
2,57
11,9
29
WH-UX12DE5
49
66
1340 x 900 x 320
107
9,52 (3/8")
15,88 (5/8")
3,10
3 – 30
7
15
50
20
–20 to 35
25 – 55
WH-SXF09D3E8
9
4,74
9
2,81
9
2,54
892 x 502 x 353
50
R1¼
3
190
25,8
3
1,9
2,9
10,4
WH-UX09DE8
49
66
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
3,10
3 – 30
7
15
50
20
–20 to 35
25 – 55
WH-SXF12D9E8
12
4,67
12
2,7
12
2,4
892 x 502 x 353
51
R1¼
3
190
34,4
9
2,57
3,9
11,9
WH-UX12DE8
49
66
1340 x 900 x 320
109
9,52 (3/8")
15,88 (5/8")
3,10
3 – 30
7
15
50
20
–20 to 35
25 – 55
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
46
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
AQUAREA
NEW
2011
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· MAXIMUM 30 m RISE BETWEEN THE OUTDOOR UNIT AND THE
HYDRAULIC MODULE
· CONSTANT CAPACITY AT OUTDOOR TEMPERATURES DOWN TO -15 °C
(AT A HEATING WATER TEMPERATURE OF 35 °C)
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
· Environmentally-friendly refrigerant gas R410A
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Control on the hydraulic module
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Easy-to-access pressure gauge for easy control of the water pressure
· Easy-to-open hydraulic module and outdoor unit
WH-UX09DE5
WH-UX12DE5
WH-UX09DE8
WH-UX12DE8
WH-TD20E3E5
WH-TD30E3E5
47
100%
capacity
at -15°C
AQUAREA T-CAP
AQUA
QUAREA T
T-CA
CAP
CA
at -15°C
capacity
100%
NEW
iPHONE & ANDROID
READY
AQUAREA SXC // BI-BLOC // T-CAP // HEATING AND COOLING
SINGLE-PHASE // THREE-PHASE
The Aquarea SXC is the new Aquarea product from Panasonic for heating and cooling. T-CAP stands for Total capacity
as this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical
booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water
temperature.
The new SXC is ideal for houses where maintaining the same capacity is important such as new houses or
houses without support from an external boiler.
The SXC can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating,
low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase
efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better
heating or cooling control and management.
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
solar
panels
connection
SOLAR KIT
domestic
hot
water
5 year
compressor
warranty
DHW
OPTIONAL
BI-BLOC // AQUAREA T-CAP // HEATING AND COOLING // SXC
SINGLE-PHASE
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Cooling capacity at 35°C
EER at 35°C with cooling water temperature at 7/12°C
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
Liquid
Gas
Refrigerant (R410A)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R410A)
I/D&O/D Hight Difference
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
kW
kW
kW
mm
kg
W
l/min
kW
kW
A
A
dB(A)
dB
mm
kg
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
WH-SXC09D3E5
9
4,74
9
2,81
9
2,54
7
3,11
892 x 502 x 353
48
R1¼
3
180
25,8
3
1,9
10,4
25
WH-UX09DE5
49
66
1340 x 900 x 320
107
9,52 (3/8")
15,88 (5/8")
3,10
3 – 30
7
15
50
20
–20 to 35
25 – 55
THREE-PHASE
WH-SXC12D6E5
12
4,67
12
2,7
12
2,4
10
2,78
892 x 502 x 353
51
R1¼
3
180
34,4
6
2,57
16,7
29
WH-UX12DE5
50
67
1340 x 900 x 320
107
9,52 (3/8")
15,88 (5/8")
2,75
3 – 30
7
15
50
20
–20 to 35
25 – 55
WH-SXC09D3E8
9
4,74
9
2,81
9
2,54
7
3,11
892 x 502 x 353
51
R1¼
3
180
25,8
3
1,9
3,5
10,4
WH-UX09DE8
49
66
1340 x 900 x 320
110
9,52 (3/8")
15,88 (5/8")
2,75
3 – 30
7
15
50
20
–20 to 35
25 – 55
WH-SXC12D9E8
12
4,67
12
2,7
12
2,4
10
2,78
892 x 502 x 353
52
R1¼
3
180
34,4
9
2,57
5,6
11,9
WH-UX12DE8
50
67
1340 x 900 x 320
110
9,52 (3/8")
15,88 (5/8")
2,75
3 – 30
7
15
50
20
–20 to 35
25 – 55
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
48
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
AQUAREA
NEW
2011
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· MAXIMUM 20 m RISE BETWEEN THE OUTDOOR UNIT AND THE
HYDRAULIC MODULE
· CONSTANT CAPACITY AT OUTDOOR TEMPERATURES DOWN TO -15 °C
(AT A HEATING WATER TEMPERATURE OF 35 °C)
· COOLING TEMPERATURE RANGE 5–20 °C
WH-UX09DE5
WH-UX12DE5
WH-UX09DE8
WH-UX12DE8
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
· Environmentally-friendly refrigerant gas R410A
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Control on the hydraulic module
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Easy-to-access pressure gauge for easy control of the water pressure
· Easy-to-open hydraulic module and outdoor unit
WH-TD20E3E5
WH-TD30E3E5
49
100%
capacity
at -15°C
AQUAREA T-CAP
AQUA
QUAREA T
T-CA
CAP
CA
at -15°C
capacity
100%
NEW
iPHONE & ANDROID
AQUAREA MXF // MONO-BLOC // T-CAP // HEATING ONLY
SINGLE-PHASE // THREE-PHASE
The Aquarea MXF is the new Aquarea product from Panasonic for central heating. T-CAP stands for Total capacity as
this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical booster
heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water
temperature.
The new MXF is ideal for houses where maintaining the same capacity is important such as new houses or houses
without support from an external boiler.
The MXF can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating,
low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase
efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better
heating control and management.
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
down to
-20ºC in
connection
heating mode
OUTDOOR
TEMPERATURE
R410A
boiler
solar
panels
connection
RETROFIT
SOLAR KIT
domestic
hot
water
5 year
compressor
warranty
DHW
OPTIONAL
MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MXF
SINGLE-PHASE
OUTDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35 °C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (^aT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
°C
°C
WH-MXF09D3E5
9
4,74
9
2,81
9
2,54
49
66
1410 x 1283 x 320
155
R1¼
3
190
25,8
3
1,9
8,8
25
–20 to 35
25 – 55
THREE-PHASE
WH-MXF12D6E5
12
4,67
12
2,7
12
2,4
50
67
1410 x 1283 x 320
155
R1¼
3
190
34,4
6
2,57
11,9
29
–20 to 35
25 – 55
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
50
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
WH-MXF09D3E8
9
4,74
9
2,81
9
2,54
49
66
1410 x 1283 x 320
158
R1¼
3
190
25,8
3
1,9
2,9
10,4
–20 to 35
25 – 55
WH-MXF12D9E8
12
4,67
12
2,7
12
2,4
50
67
1410 x 1283 x 320
158
R1¼
3
190
34,4
9
2,57
3,9
11,9
–20 to 35
25 – 55
AQUAREA
NEW
2012
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised according to the return water temperature
· Autonomous management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Single-unit range, with no refrigerant connections
· Wired control panel for installation in the house
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Outdoor unit easy to open for maintenance
WH-TD20E3E5
WH-TD30E3E5
51
100%
capacity
at -15°C
AQUAREA T-CAP
AQUA
QUAREA T
T-CA
CAP
CA
at -15°C
capacity
100%
NEW
iPHONE & ANDROID
AQUAREA MXC // MONO-BLOC // T-CAP //
HEATING AND COOLING SINGLE-PHASE // THREE-PHASE
The Aquarea MXC is the new Aquarea product from Panasonic for heating and cooling. T-CAP stands for Total capacity
as this new line-up is able to maintain the same nominal capacity even at -15°C without the help of an electrical
booster heater. T-CAP is also able to provide extremely high efficiency, whatever the outside temperature or the water
temperature.
The new MXC is ideal for houses where maintaining the same capacity is important such as new houses or houses
without support from an external boiler.
The MXC can be adapted to an existing installation such as a boiler backup or to a new installation with floor heating,
low-temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase
efficiency and minimize the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better
heating or cooling control and management.
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R410A
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
solar
panels
connection
SOLAR KIT
domestic
hot
water
5 year
compressor
warranty
DHW
OPTIONAL
MONO-BLOC // AQUAREA T-CAP // HEATING AND COOLING// MXC
SINGLE-PHASE
OUTDOOR UNIT
Heating Capacity at +7°C
COP at +7°C with heating water temperature at 35°C
Heating Capacity at -7°C
COP at -7°C with heating water temperature at 35°C
Heating Capacity at -15°C
COP at -15°C with heating water temperature at 35°C
Cooling capacity at 35°C
EER at 35°C with cooling water temperature at 7/12°C
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
No. of Speed
Input power(max)
Heating water flow (^aT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
kW
kW
kW
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
°C
°C
WH-MXC09D3E5
9
4,74
9
2,81
9
2,54
7
3,11
49
66
1410 x 1283 x 320
155
R1¼
3
190
25,8
3
1,9
10,4
25
–20 to 35
22 - 55 / 5 - 20
THREE-PHASE
WH-MXC12D6E5
12
4,67
12
2,7
12
2,4
10
2,78
50
67
1410 x 1283 x 320
155
R1¼
3
190
34,4
6
2,57
16,7
29
–20 to 35
22 - 55 / 5 - 20
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
52
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
WH-MXC09D3E8
9
4,74
9
2,81
9
2,54
7
3,11
49
66
1410 x 1283 x 320
158
R1¼
3
190
25,8
3
1,9
2,9
10,4
–20 to 35
22 - 55 / 5 - 20
WH-MXC12D9E8
12
4,67
12
2,7
12
2,4
10
2,78
50
67
1410 x 1283 x 320
158
R1¼
3
190
34,4
9
2,57
3,9
11,9
–20 to 35
22 - 55 / 5 - 20
AQUAREA
NEW
2012
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 55 °C
· WORKS DOWN TO –20 °C
· COOLING TEMPERATURE RANGE 5–20 °C
ENERGY AND ENVIRONMENTAL EFFICIENCY
· 78% more efficient than an electrical convection system
· Maximum COP of 4.74 for the 9 kW model
COMFORT
· Optimum control possible with a room temperature thermostat (not supplied)
· Maximum hydraulic module output temperature: 55 °C
· Power optimised according to the return water temperature
· Autonomous management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Single-unit range, with no refrigerant connections
· Wired control panel for installation in the house
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Outdoor unit easy to open for maintenance
WH-TD20E3E5
WH-TD30E3E5
53
AQUAREA SHF // BI-BLOC // HT // HEATING ONLY
SINGLE-PHASE // THREE-PHASE
output
water
65ºC
For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution
is probably the most adequate as Aquarea HT provides output water temperatures of 65°C even at -15°C.
Aquarea HT is able to deliver 65°C with the Heat Pump alone.
HIGH TEMP
HEAT PUMP
H
HEAT
PU
UMP
HIGH TEMP
HIGH
TEM
MP
65ºC
water
output
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R407C
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
domestic
solar
hot
panels
connection
water
SOLAR KIT
5 year
compressor
warranty
DHW
OPTIONAL
BI-BLOC // AQUAREA HT // HEATING ONLY // SHF
SINGLE-PHASE
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C
Heating Capacity at -7°C
COP at -7°C
Heating Capacity at -15°C
COP at -15°C
Heating Capacity at +7°C
COP at +7°C
Heating Capacity at -7°C
COP at -7°C
Heating Capacity at -15°C
COP at -15°C
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
kW
With heating water
temperature at 35°C
kW
kW
kW
With heating water
temperature at 65°C
No. of Speed
Input power(max)
Heating water flow (ΔT=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
Liquid
Gas
Refrigerant (R407C)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R407C)
I/D&O/D Hight Difference
Operation
Outdoor Ambient
Range
Water Outlet (at-2/-7/-15) 2)
kW
kW
mm
kg
W
l/min
kW
kW
A
A
dB(A)
dB
mm
kg
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
THREE-PHASE
WH-SHF09D3E5*
9
4,55
9
2,7
9
2,4
9
2,25
8,9
1,64
7,8
1,32
892 x 502 x 353
WH-SHF12D6E5*
12
4,4
12
2,5
12
2,15
12
2,2
9,6
1,61
8
1,3
892 x 502 x 353
WH-SHF09D3E8*
9
4,55
9
2,7
9
2,4
9
2,25
8,9
1,64
7,8
1,32
892 x 502 x 353
WH-SHF12D9E8*
12
4,4
12
2,5
12
2,15
12
2,2
9,6
1,61
8
1,3
892 x 502 x 353
3
6
3
9
WH-UH09DE5
49
66
1340 x 900 x 320
WH-UH12DE5
50
67
1340 x 900 x 320
WH-UH09DE8
49
66
1340 x 900 x 320
WH-UH12DE8
50
67
1340 x 900 x 320
9,52 (3/8")
15,88 (5/8")
2,95
3 – 30
7
15
70
20
–20 to 35
25 – 65
9,52 (3/8")
15,88 (5/8")
2,95
3 – 30
7
15
70
20
–20 to 35
25 – 65
9,52 (3/8")
15,88 (5/8")
2,95
3 – 30
7
15
70
20
–20 to 35
25 – 65
9,52 (3/8")
15,88 (5/8")
2,95
3 – 30
7
15
70
20
–20 to 35
25 – 65
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
* Tentative specifications.
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
54
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
AQUAREA
NEW
2012
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 65 °C
· WORKS DOWN TO –20 °C
· MAXIMUM 30 M RISE BETWEEN THE OUTDOOR UNIT AND THE
HYDRAULIC MODULE
ENERGY AND ENVIRONMENTAL EFFICIENCY
· Maximum COP of 4.55
· Environmentally-friendly refrigerant gas R407C
COMFORT
· Maximum hydraulic module output temperature: 65 °C
· Optimum control possible with an outside thermometer (not supplied)
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Control on the hydraulic module
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Easy-to-access pressure gauge for easy control of the water pressure
· Easy-to-open hydraulic module and outdoor unit
WH-UH09DE5
WH-UH12DE5
WH-UH09DE8
WH-UH12DE8
WH-TD20E3E5
WH-TD30E3E5
55
AQUAREA MHF // MONO-BLOC // HT // HEATING ONLY
SINGLE-PHASE // THREE-PHASE
output
water
65ºC
For a house with high temperature radiators (for example, cast iron radiators), the Aquarea High Temperature Solution
is probably the most adequate as Aquarea HT provides output water temperatures of 65°C even at -15°C.
Aquarea HT is able to deliver 65°C with the Heat Pump alone.
HIGH TEMP
HEAT PUMP
H
HEAT
PU
UMP
HIGH TEMP
HIGH
TEM
MP
65ºC
water
output
NEW
iPHONE & ANDROID
READY
CONTROL YOUR HEAT
PUMP WITH THE
environmentally
high
friendly
efficiency
heating
refrigerant
SMART DEVICE
VIA SMARTPHONES &
INTERNET
R407C
down to
-20ºC in
boiler
connection
heating mode
OUTDOOR
TEMPERATURE
RETROFIT
domestic
solar
hot
panels
connection
water
SOLAR KIT
5 year
compressor
warranty
DHW
OPTIONAL
MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MHF
SINGLE-PHASE
INDOOR UNIT
Heating Capacity at +7°C
COP at +7°C
Heating Capacity at -7°C
COP at -7°C
Heating Capacity at -15°C
COP at -15°C
Heating Capacity at +7°C
COP at +7°C
Heating Capacity at -7°C
COP at -7°C
Heating Capacity at -15°C
COP at -15°C
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Water pipe connector
Pump
kW
kW
With heating water
temperature at 35°C
kW
kW
kW
With heating water
temperature at 65°C
No. of Speed
Input Power(max)
Heating water flow (T=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Running and starting Current
Maximum Current
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
kW
dB(A)
dB
mm
kg
W
l/min
kW
kW
A
A
°C
°C
THREE-PHASE
WH-MHF09D3E5*
9
4,55
9
2,7
9
2,4
9
2,25
8,9
1,64
7,8
1,32
49
66
1410 x 1283 x 320
WH-MHF12D6E5*
12
4,4
12
2,5
12
2,15
12
2,2
9,6
1,61
8
1,3
50
67
1410 x 1283 x 320
WH-MHF09D3E8*
9
4,55
9
2,7
9
2,4
9
2,25
8,9
1,64
7,8
1,32
49
66
1410 x 1283 x 320
WH-MHF12D9E8*
12
4,4
12
2,5
12
2,15
12
2,2
9,6
1,61
8
1,3
50
67
1410 x 1283 x 320
3
6
3
9
-20 to 35
25 – 65
-20 to 35
25 – 65
-20 to 35
25 – 65
-20 to 35
25 – 65
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
TANKS (MORE TANK ON THE ACCESSORIES PART)
OPTIONAL STANDARD SANITARY TANK
Water volume
Max. water temperature
Dimension
Hight / Diameter
Weight
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C (insulated tested under EN12897)
3 Way valve included
56
L
°C
mm
kg
m2
kWh/24h
WH-TD20E3E5
200
85
1230 / 580
42
230V
Inox
1,4
1,7
YES
WH-TD30E3E5
300
85
1700 / 580
54
230V
Inox
1,8
2
YES
AQUAREA
NEW
2012
TECHNICAL FOCUS
· NEW! OPTIONAL SMARTPHONE CONTROL WITH INTENSISHOME®
DEVICE
· RANGE FROM 9 TO 12 KW, SINGLE AND THREE-PHASE
· MAXIMUM HYDRAULIC MODULE OUTPUT TEMPERATURE: 65 °C
· WORKS DOWN TO –20 °C
ENERGY AND ENVIRONMENTAL EFFICIENCY
· Maximum COP of 4.55
· Environmentally-friendly refrigerant gas R407C
COMFORT
· Maximum hydraulic module output temperature: 65 °C
· Optimum control possible with an outside thermometer (not supplied)
· Power optimised based on the return water temperature
· Built-in management of the hot water cylinder and heating
EASY TO USE
· NEW! Optional Smartphone control with IntensisHome® device
· Easy programming on the control panel
EASY INSTALLATION AND MAINTENANCE
· Easy-to-access pressure gauge for easy control of the water pressure
· Easy-to-open outdoor unit
WH-TD20E3E5
WH-TD30E3E5
57
AQUAREA PRO
THE NEW PANASONIC SOLUTION FOR CHILLED
AND HOT WATER PRODUCTION!
FROM 28 kW to 80 kW
58
AQUAREA
NEW
2012
KEY BENEFITS:
- No cascade installation up to 80 kW with GHP outdoor unit and 51,3 kW with ECOi
- No Glycol needed when WHE is located on the heated part of the building
- Full line-up of outdoor units which can cover up to 80 kW heat demand
- Large choice-remote controls and interfaces
- 3.25 COP with water at 45°C and outdoor temperature of +7°C
With ECOi outdoor units:
With GHP outdoor units:
· Maximum hot water outlet temperature: 45 °C
· Minimum chilled water outlet temperature: 7 °C
· Outdoor temperature range in cooling mode: +5 °C to +43 °C
· Outdoor temperature range in heating mode: -20 °C to +15 °C
· Hot water outlet temperatures from 35 °C to 55 °C
· Chilled water outlet temperatures from 5 °C to 15 °C
· Outdoor temperature range in cooling mode: -10 °C to +43 °C
· Minimum outdoor temperature in heating mode: -21 °C
ECOi Water Heat Exchanger
ECO G Water Heat Exchanger
Electrical VRF with water heat exchanger
· With this easy to install Aquarea Pro system, you can now cover projects up to
51 kW hot water demand or 44 kW on chilled application on a efficient way
and cost effective.
Mixed System Application
· Combined with a water heat exchanger unit, the Panasonic GHP can create
a flexible system--the ideal replacement for existing chiller and boiler
systems.
· The GHP Multi System can have an indoor unit plus a GHP chiller. When
the two systems are operated independently, an outdoor unit with 130%
capacity can be connected.
SYSTEM EXAMPLE
SYSTEM EXAMPLE
Floor Heating
Floor Heating
Fan Coil Unit
ECO G Chiller
Water Heat Exchanger Buffer Tank
Fan Coil Unit
ECOi Chiller
Water Heat Exchanger
Buffer Tank
Duct*
Refrigerant
piping
Duct*
Refrigerant
piping
Outdoor unit
Water Piping
Water Piping
Air Handling Unit
Outdoor unit
Air Handling Unit
* Standard DX type indoor unit system
control wiring
* Standard DX type indoor unit system
Note: The mode of running of outdoor unit depends on the water heat exchanger’s mode. The water pump is not
included in the water heat exchanger unit. For simultaneous operation, however, the maximum capacity is 130%.
Please inquire details of this system design of Panasonic.
Note: The mode of running of outdoor unit depends on the water heat exchanger’s mode. The water pump is not
included in the water heat exchanger unit. For simultaneous operation, however, the maximum capacity is 130%.
Please inquire details of this system design of Panasonic.
59
high
efficiency
heating
AQUAREA PRO // NEW ECOi 2-WAY 6 SERIES WITH WATER HEAT EXCHANGER
DESIGNED FOR CHILLED AND HOT WATER PRODUCTION
With this easy to install Aquarea Pro system, you can now cover projects up to 51 kW hot water demand or 44 kW on
chilled application on a efficient way and cost effective.
heating
efficiency
f
high
g
environmentally
friendly
refrigerant
R410A
down to
-20ºC in
heating mode
5 year
compressor
warranty
OUTDOOR
TEMPERATURE
AQUAREA PRO // GAS VRF ECOi + WATER HEAT EXCHANGER
Water heat exchanger
Nominal Heating Capacity
kW
kW
Nomimal Cooling Capacity
Heating Capacity at +7°C, heating water temperature at 35°C kW
COP at +7°C with heating water temperature at 35°C
Heating Capacity at +7°C, heating water temperature at 45°C kW
COP at +7°C with heating water temperature at 45°C
Heating Capacity at -7°C, heating water temperature at 35°C kW
COP at -7°C, heating water temperature at 35°C
Heating Capacity at -15°C, heating water temperature at 35°C
COP at -15°C with heating water temperature at 35°C
kW
Heating capacity at +32°C, outlet tp 6°C, inlet tp 12°C
kW
COP at +32°C, outlet tp 6°C, inlet tp 12°C
Heating capacity at +35°C, outlet tp 7°C, inlet tp 12°C
kW
COP at +32°C, outlet tp 6°C, inlet tp 12°C
Dimensions (H x W x D)
mm
Weight
kg
Water pipe connector
Pump
No. of Speed
Input Power(max)
W
Heating water flow (∆T=5 K. 35°C)
l/min
Capacity of integrated electric heater
kW
Input Power
kW
Starting Current
A
Maximum Current
A
Outdoor unit
Sound pressure level
dB(A)
Sound power level
dB
Dimensions (H x W x D)
mm
Weight
kg
Pipe Diameter
Liquid
mm (Inch)
Gas
mm (Inch)
Refrigerant (R410A)
kg
Pipe Length Range
m
Pipe Length for nominal capacity
m
Pipe Length for additional gas
m
Additional Gas Amount (R410A)
g/m
I/D&O/D Hight Difference
m
Operation Range
Outdoor Ambient
°C
Water Outlet (at-2/-7/-15) 2) °C
Eco-i
S-250WX2E5
28
S-500WX2E5
25
51,3
50
28
25
28,0
3,25
23,4
2,52
20,7
2,34
51,3
50
51,3
3,10
44,9
2,42
39,3
2,24
1000x395x965
165
Rp2 Nut thread (50A)
(Field supply)
--4,3
(Not equipped)
0,01
--0,07
U-10ME1E81
59
73,5
1758x770x930
281
22,22
9,52
"6.3 (Need Additional charge at site)
max. 170
7,5
0<
Reffer to Manual
50 (OD above) 35 (OD below)
-20 ~ 15
35 ~ 45
1000x395x965
190
Rp2 Nut thread (50A)
(Field supply)
--8,6
(Not equipped)
0,01
--0,07
U-20ME1E81
63
77,5
1758x1540x930
423
28,58
15,88
"9.0 (Need Additional charge at site)
max. 170
7,5
0<
Reffer to Manual
"50 (OD above) 35 (OD below)"
-20 ~ 15
35 ~ 45
In ECOi 2-way systems, the water heat exchanger can only be used as a one-to-one solution for ECOi 2-way systems. A combination with other indoor or outdoor units is not allowed.
* Max. piping lengths for 100 % one-to-one combination ratio.
* All values shown as tentative data.
Rating conditions:
Cooling: outdoor 35 °C; water outlet/inlet: 7/12 °C.
Heating: outdoor 7 °C DB / 6 °C WB, water outlet/inlet: 45/40 °C
60
AQUAREA
NEW
2012
OPTIONAL CONTROLLER
Timer remote controller
CZ-RTC2
TECHNICAL FOCUS
- UP TO 51 kW ON ONLY 1 OUTDOOR UNIT
- PRODUCE HOT WATER AT 45°C WITH HIGH EFFICIENCY
· CHILLED WATER OUTLET TEMPERATURES FROM 5 °C TO 15 °C
- LARGE LINE-UP OF REMOTE CONTROLS FROM ECOI LINE-UP
- HIGH EFFICIENCY UP TO -20°C ON HEATING MODE
- HIGH EFFICIENCY UP TO +5 °C ON COOLING MODE (CHILLER
APPLICATION)
DESCRIPTION
· New water heat exchanger for GHP and ECOi 6 series, dimensions reduced by 45 %
· Operation and control by wired remote control CZ-RTC2
· Energy-efficient capacity control
· Stainless steel plate heat exchanger with anti-freeze protection control
· Change-over between heating and cooling operation
· Maximum distance between outdoor unit and water heat exchanger: 170 m
· Maximum hot water outlet temperature: 45 °C
· Minimum chilled water outlet temperature: 7 °C
· Outdoor temperature range in cooling mode: +5 °C to +43 °C
· Outdoor temperature range in heating mode: -20 °C to +15 °C
61
AQUAREA PRO // NEW GAS VRF ECO G WITH WATER HEAT EXCHANGER
high
efficiency
heating
DESIGNED CHILLED AND HOT WATER PRODUCTION
NEW Aquarea Pro GHP+WHE system, based of Gas Heat Pump technology, for Hot water production and Chilled
application even where electricity is not available!
heating
efficiency
f
high
g
environmentally
friendly
refrigerant
down to
-20ºC in
heating mode
OUTDOOR
TEMPERATURE
R410A
WATER HEAT EXCHANGER
Nominal Heating Capacity
kW
kW
Nomimal Cooling Capacity
Heating Capacity at +7°C, heating water temperature at 35°C kW
COP at +7°C with heating water temperature at 35°C
Heating Capacity at +7°C, heating water temperature at 45°C kW
COP at +7°C with heating water temperature at 45°C
Heating Capacity at -7°C, heating water temperature at 35°C kW
COP at -7°C, heating water temperature at 35°C
Heating Capacity at -15°C, heating water temperature at 35°C
COP at -15°C with heating water temperature at 35°C
Cooling capacity at +32°C, outlet tp 6°C, inlet tp 12°C
kW
EER at +32°C, outlet tp 6°C, inlet tp 12°C
Cooling capacity at +35°C, outlet tp 7°C, inlet tp 12°C
kW
EER at +32°C, outlet tp 6°C, inlet tp 12°C
Dimensions (H x W x D)
mm
Weight
kg
Water pipe connector
Pump
No. of Speed
Input Power(max)
Heating water flow (∆T=5 K. 35°C)
Capacity of integrated electric heater
Input Power
Starting Current
Maximum Current
Outdoor unit
OUTDOOR UNIT
Sound pressure level
Sound power level
Dimensions (H x W x D)
Weight
Pipe Diameter
Liquid
Gas
Refrigerant (R410A)
Pipe Length Range
Pipe Length for nominal capacity
Pipe Length for additional gas
Additional Gas Amount (R410A)
I/D&O/D Hight Difference
Operation Range
Outdoor Ambient
Water Outlet (at-2/-7/-15) 2)
W
l/min
KW
kW
A
A
dB(A)
dB
mm
kg
mm (Inch)
mm (Inch)
kg
m
m
m
g/m
m
°C
°C
S-250WX2E5
30
25
S-500WX2E5
60
50
S-710WX2E5
80
67
30
60
1,49
59,2
0,75
59,2
0,75
80
1,34
77,4
0,76
77,4
0,76
1000x395x965
110
Rp2 Nut thread (50A)
(Field supply)
--4,3
(NOT EQUIPPED)
0,01
--0,07
-
1000x395x965
130
Rp2 Nut thread (50A)
(Field supply)
--8,6
(NOT EQUIPPED)
0,01
--0,07
U-20GE2E5
U-20GE2E5
58
83
2228x1650x1000
770
28,58
15,88
"11.5 *Need additional chatge at site"
max. 170
7
0<
Refer to Manual
"50 (OD above) / 35 (OD below)"
-21 ~ 15.5
35 ~ 55
1000x395x965
150
Rp2 Nut thread (50A)
(Field supply)
--12,2
(NOT EQUIPPED)
0,01
--0,07
U-30GE2E5
U-30GE2E5
63
86
2228x2026x1000
830
31,75
19,05
"11.5 *Need additional chatge at site"
max. 170
7
0<
Refer to Manual
"50 (OD above) / 35 (OD below)"
-21 ~ 15.5
35 ~ 55
COP classification is at 230 V only in accordance with EU directive 2003/32/EC. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height.
Not valid in case of mixed systems, combination ratio in case of mixed systems: 50 to 130 %, combination ratio in case of one-to-one-systems: 100 %.
Water circulating pump. Power supply: 230 V / 1 Ph / 50 Hz; power input: 0.75 kW; external pressure head: 6 m
Performance calculation in agreement with EN14511.
Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height
Conditions : Water input temperature: 30 °C. Water output temperature: 35 °C
62
AQUAREA
NEW
2012
OPTIONAL CONTROLLER
Timer remote controller
CZ-RTC2
TECHNICAL FOCUS
· UP TO 80 kW ON ONLY 1 OUTDOOR UNIT, WE CAN PROVIDE A 25 OR
30HP GHP FOR THIS WHE
· HOT WATER OUTLET TEMPERATURES FROM 35 °C TO 55 °C
· CHILLED WATER OUTLET TEMPERATURES FROM 5 °C TO 15 °C
- LARGE LINE-UP OF REMOTE CONTROLS FROM ECOI LINE-UP
- HIGH EFFICIENCY UP TO -20°C ON HEATING MODE
- HIGH EFFICIENCY UP TO +5 °C ON COOLING MODE (CHILLER
APPLICATION)
DESCRIPTION
· Hot water outlet temperatures from 35 °C to 55 °C
· Chilled water outlet temperatures from 5 °C to 15 °C
· Operation and control by wired remote control CZ-RTC2
· Energy-efficient capacity control
· Stainless steel plate heat exchanger with anti-freeze protection control
· Change-over between heating and cooling operation
· Maximum distance between outdoor unit and water heat exchanger: 170 m
· Possibility to mix DX and water heat exchanger systems
· No cooling tower necessary
· Hot water outlet temperatures from 35 °C to 55 °C
· Chilled water outlet temperatures from 5 °C to 15 °C
· Outdoor temperature range in cooling mode: -10 °C to +43 °C
· Minimum outdoor temperature in heating mode: -21 °C
HOT WATER SUPPLY FUNCTION
SYSTEM ADVANTAGE
The engine waste heat, which is normally exhausted into the atmosphere, is
recovered via the heat exchanger and effectively used as hot water, so the
GHP Chiller acts as a sub system that alleviates the load on the client’s
main hot water system, and therefore offers ‘free’ hot water.
CAPACITY AT COOLING STANDARD POINT
OUTLET TEMP 75ºC
Outdoor unit
kW
U-16GE2E5
Hot water
16.00
U-20GE2E5
20.00
U-20GEG2E5
22.00
U-25GE2E5
25.00
Hot water piping allowable pressure
GHP
PANASONIC
0.7
Hot water circulation rate
MPa
3.9
Hot water tube size
m³/h
Rp 3/4
Manometer
Water tank
Expansion tank
Boiler
Pump
Valve
Cold water
63
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE
MONO-BLOC // 6 AND 9 KW AQUAREA // HEATING ONLY // MDF
WH-MDF06D3E5
Tamb
HC
LWC
30
6,15
-15
5,18
-7
5,00
2
6,00
7
7,30
25
IP
30
2,52
1,70
1,25
1,15
0,80
COP
30
2,44
3,05
4,02
5,24
9,18
HC
35
5,90
5,15
5,00
6,00
7,10
IP
35
2,68
1,94
1,47
1,37
0,95
COP
35
2,20
2,65
3,40
4,38
7,47
HC
40
5,65
5,13
5,00
6,00
6,90
IP
40
2,84
2,19
1,70
1,60
1,11
COP
40
1,99
2,35
2,95
3,76
6,24
HC
45
5,40
5,10
5,00
6,00
6,70
IP
45
3,00
2,43
1,92
1,82
1,26
COP
45
1,80
2,10
2,60
3,30
5,32
HC
50
5,20
5,45
5,00
6,00
6,50
IP
50
3,17
2,83
2,21
2,11
1,43
COP
50
1,64
1,93
2,26
2,84
4,55
HC
55
5,00
5,80
5,00
6,00
6,30
IP
55
3,34
3,22
2,50
2,40
1,60
COP
55
1,50
1,80
2,00
2,50
3,94
WH-MDF09D3E5
Tamb
HC
LWC
30
7,90
-15
7,80
-7
7,00
2
9,00
7
9,00
25
IP
30
3,65
3,41
2,04
1,90
1,02
COP
30
2,17
2,29
3,44
4,75
8,82
HC
35
7,60
7,70
7,00
9,00
9,00
IP
35
3,80
3,66
2,33
2,20
1,34
COP
35
2,00
2,10
3,00
4,09
6,72
HC
40
7,30
7,60
7,00
9,00
9,00
IP
40
3,96
3,91
2,63
2,51
1,66
COP
40
1,85
1,94
2,67
3,59
5,42
HC
45
7,00
7,50
7,00
9,00
9,00
IP
45
4,11
4,16
2,92
2,81
1,98
COP
45
1,70
1,80
2,40
3,20
4,55
HC
50
6,45
7,55
7,00
8,95
9,00
IP
50
4,09
4,62
3,40
3,34
2,23
COP
50
1,58
1,63
2,06
2,68
4,04
HC
55
5,90
7,60
7,00
8,90
9,00
IP
55
4,06
5,08
3,88
3,87
2,48
COP
55
1,45
1,50
1,80
2,30
3,63
BI-BLOC // HIGH-CONNECTIVITY // HEATING MODE // SDF
WH-SDF07C3E5
Tamb
HC
LWC
30
4,60
-15
5,15
-7
6,70
2
7,00
7
7,00
25
IP
30
1,87
1,80
1,83
1,43
0,79
COP
30
2,46
2,86
3,66
4,90
8,86
HC
35
4,60
5,15
6,55
7,00
7,00
IP
35
2,00
1,94
1,98
1,59
0,93
COP
35
2,30
2,65
3,31
4,40
7,53
HC
40
4,60
5,08
6,58
7,00
6,40
IP
40
2,19
2,14
2,29
1,77
1,03
COP
40
2,10
2,37
2,87
3,95
6,21
HC
45
4,60
5,00
6,60
7,00
6,10
IP
45
2,42
2,38
2,64
2,12
1,17
COP
45
1,90
2,10
2,50
3,30
5,21
HC
50
4,55
4,90
6,30
6,90
5,90
IP
50
2,68
2,47
2,90
2,30
1,33
COP
50
1,70
1,98
2,17
3,00
4,44
HC
55
4,50
4,80
6,00
6,80
5,70
IP
55
3,00
2,67
3,16
2,72
1,49
COP
55
1,50
1,80
1,90
2,50
3,83
WH-SDF09C3E5
Tamb
HC
LWC
30
6,00
-15
6,10
-7
6,80
2
9,00
7
9,00
25
IP
30
2,55
2,16
1,87
1,93
1,07
COP
30
2,35
2,82
3,64
4,66
8,41
HC
35
5,90
5,90
6,70
9,00
9,00
IP
35
2,68
2,36
2,16
2,20
1,27
COP
35
2,20
2,50
3,10
4,09
7,09
HC
40
5,50
5,85
6,70
9,00
8,40
IP
40
2,82
2,63
2,38
2,45
1,40
COP
40
1,95
2,22
2,82
3,67
6,00
HC
45
5,40
5,80
6,60
9,00
8,00
IP
45
3,00
2,90
2,64
2,81
1,59
COP
45
1,80
2,00
2,50
3,20
5,03
HC
50
5,20
5,80
6,30
8,95
7,80
IP
50
3,14
3,06
2,90
3,23
1,81
COP
50
1,66
1,90
2,17
2,77
4,31
HC
55
5,00
5,80
6,00
8,90
7,50
IP
55
3,33
3,22
3,16
3,87
2,03
COP
55
1,50
1,80
1,90
2,30
3,69
WH-SDF12C6E5
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,50
3,41
3,14
2,14
1,42
COP
30
2,66
3,05
3,76
5,61
8,45
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,66
3,70
3,35
2,57
1,70
COP
35
2,43
2,70
3,40
4,67
7,06
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,83
3,99
3,57
3,00
1,98
COP
40
2,22
2,41
3,08
4,00
5,96
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,99
4,28
3,78
3,43
2,27
COP
45
2,03
2,15
2,80
3,50
5,15
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,09
4,30
3,98
3,82
2,53
COP
50
1,83
2,02
2,46
3,14
4,55
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,20
4,31
4,18
4,20
2,78
COP
55
1,67
1,90
2,18
2,86
4,10
HYDRAULIC PUMP PERFORMANCE
( 09D3 // 09C3 // 12C6 // 14C6 // 16C9 )
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1
EXTERNAL STATIC PRESSURE (kPa)
EXTERNAL STATIC PRESSURE (kPa)
( 06D3 // 07C3 )
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1
WATER FLOW RATE (L/min)
WATER FLOW RATE (L/min)
This data is measured by Panasonic in accordance with EN14511-2 standard.
This data is for reference purpose only, and does not guarantee the performance.
64
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
AQUAREA
WH-SDF14C6E5
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,91
3,73
3,51
2,60
1,75
COP
30
2,53
2,98
3,68
5,38
8,00
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,05
4,08
3,73
3,11
2,10
COP
35
2,35
2,62
3,32
4,50
6,67
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,19
4,43
3,95
3,63
2,45
COP
40
2,15
2,30
3,01
3,86
5,71
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,33
4,78
4,17
4,14
2,80
COP
45
1,99
2,05
2,73
3,38
5,00
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,45
4,76
4,29
4,61
3,05
COP
50
1,78
1,91
2,42
2,95
4,59
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,56
4,74
4,40
5,08
3,44
COP
55
1,60
1,79
2,16
2,62
4,07
WH-SDF16C6E5
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,13
4,07
3,78
3,25
2,35
COP
30
2,57
2,92
3,57
4,92
6,81
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,42
4,47
4,00
3,78
2,73
COP
35
2,33
2,55
3,25
4,23
5,86
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,71
4,87
4,22
4,31
3,11
COP
40
2,12
2,22
2,94
3,71
5,14
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
5,00
5,26
4,44
4,84
3,49
COP
45
1,94
1,96
2,68
3,31
4,58
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,98
5,13
4,50
5,15
3,71
COP
50
1,77
1,87
2,40
2,95
4,31
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,95
4,99
4,55
5,45
3,93
COP
55
1,60
1,80
2,15
2,66
4,05
WH-SDF09C9E8
Tamb
HC
LWC
30
8,65
-15
9,35
-7
9,31
2
9,00
7
9,00
25
IP
30
3,10
2,95
2,39
1,58
1,09
COP
30
2,79
3,17
3,90
5,70
8,26
HC
35
8,30
9,00
9,00
9,00
9,00
IP
35
3,25
3,20
2,55
1,90
1,28
COP
35
2,55
2,81
3,53
4,74
7,03
HC
40
7,95
8,85
9,00
9,00
8,73
IP
40
3,45
3,58
2,82
2,20
1,48
COP
40
2,30
2,47
3,19
4,09
5,90
HC
45
7,60
8,70
9,00
9,00
8,46
IP
45
3,65
3,96
3,09
2,50
1,68
COP
45
2,08
2,20
2,91
3,60
5,04
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,75
3,93
3,53
2,80
1,86
COP
50
1,91
2,11
2,52
3,21
4,45
HC
55
6,70
7,90
8,80
9,00
8,10
IP
55
3,85
3,90
3,98
3,10
2,04
COP
55
1,74
2,03
2,21
2,90
3,97
WH-SDF12C9E8
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,50
3,41
3,14
2,14
1,42
COP
30
2,66
3,05
3,76
5,61
8,45
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,66
3,70
3,35
2,57
1,70
COP
35
2,43
2,70
3,40
4,67
7,06
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,83
3,99
3,57
3,00
1,98
COP
40
2,22
2,41
3,08
4,00
5,96
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,99
4,28
3,78
3,43
2,27
COP
45
2,03
2,15
2,80
3,50
5,15
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,09
4,30
3,98
3,82
2,53
COP
50
1,83
2,02
2,46
3,14
4,55
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,20
4,31
4,18
4,20
2,78
COP
55
1,67
1,90
2,18
2,86
4,10
WH-SDF14C9E8
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,91
3,73
3,51
2,60
1,75
COP
30
2,53
2,98
3,68
5,38
8,00
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,05
4,08
3,73
3,11
2,10
COP
35
2,35
2,62
3,32
4,50
6,67
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,19
4,43
3,95
3,63
2,45
COP
40
2,15
2,30
3,01
3,86
5,71
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,33
4,78
4,17
4,14
2,80
COP
45
1,99
2,05
2,73
3,38
5,00
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,45
4,76
4,29
4,61
3,05
COP
50
1,78
1,91
2,42
2,95
4,59
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,56
4,74
4,40
5,08
3,44
COP
55
1,60
1,79
2,16
2,62
4,07
WH-SDF16C9E8
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,13
4,07
3,78
3,25
2,35
COP
30
2,57
2,92
3,57
4,92
6,81
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,42
4,47
4,00
3,78
2,73
COP
35
2,33
2,55
3,25
4,23
5,86
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,71
4,87
4,22
4,31
3,11
COP
40
2,12
2,22
2,94
3,71
5,14
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
5,00
5,26
4,44
4,84
3,49
COP
45
1,94
1,96
2,68
3,31
4,58
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,98
5,13
4,50
5,15
3,71
COP
50
1,77
1,87
2,40
2,95
4,31
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,95
4,99
4,55
5,45
3,93
COP
55
1,60
1,80
2,15
2,66
4,05
65
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE
BI-BLOC // HIGH-CONNECTIVITY // ON COOLING MODE // SDC
SDC
MODELS
Tamb
16
25
35
43
HC
5,90
7,45
7,00
5,80
WH-SDC09
IP
1,01
1,59
2,25
2,59
COP
5,84
4,69
3,11
2,24
WH-SDC12
IP
1,30
2,30
3,55
3,95
HC
7,65
9,20
10,00
7,60
COP
5,88
4,00
2,82
1,92
WH-SDC14
IP
1,50
2,68
4,40
5,01
HC
8,85
10,00
11,50
9,05
COP
5,90
3,73
2,61
1,81
HC
9,62
10,51
12,20
10,08
WH-SDC16
IP
1,63
2,85
4,80
5,47
COP
5,90
3,69
2,54
1,84
MONO-BLOC // HIGH-CONNECTIVITY // HEATING MODE // MDF
WH-MDF09C3E5
Tamb
HC
LWC
30
8,65
-15
9,35
-7
9,31
2
9,00
7
9,00
25
IP
30
3,10
2,95
2,39
1,58
1,09
COP
30
2,79
3,17
3,90
5,70
8,26
HC
35
8,30
9,00
9,00
9,00
9,00
IP
35
3,25
3,20
2,55
1,90
1,28
COP
35
2,55
2,81
3,53
4,74
7,03
HC
40
7,95
8,85
9,00
9,00
8,73
IP
40
3,45
3,50
2,82
2,20
1,48
COP
40
2,30
2,53
3,19
4,09
5,90
HC
45
7,60
8,70
9,00
9,00
8,46
IP
45
3,65
3,80
3,09
2,50
1,68
COP
45
2,08
2,29
2,91
3,60
5,04
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,75
3,85
3,53
2,80
1,86
COP
50
1,91
2,16
2,52
3,21
4,45
HC
55
6,70
7,90
8,80
9,00
8,10
IP
55
3,85
3,90
3,98
3,10
2,04
COP
55
1,74
2,03
2,21
2,90
3,97
WH-MDF12C6E5
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,50
3,41
3,14
2,14
1,42
COP
30
2,66
3,05
3,76
5,61
8,45
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,66
3,70
3,34
2,57
1,70
COP
35
2,43
2,70
3,41
4,67
7,06
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,83
3,90
3,57
3,00
1,98
COP
40
2,22
2,46
3,08
4,00
5,96
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,99
4,10
3,78
3,43
2,27
COP
45
2,03
2,24
2,80
3,50
5,15
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,09
4,20
3,98
3,82
2,53
COP
50
1,83
2,07
2,46
3,14
4,55
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,20
4,31
4,18
4,20
2,78
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MDF14C6E5
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,91
3,73
3,51
2,60
1,75
COP
30
2,53
2,98
3,68
5,38
8,00
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,05
4,00
3,73
3,11
2,10
COP
35
2,35
2,68
3,32
4,50
6,67
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,19
4,20
3,95
3,63
2,45
COP
40
2,15
2,43
3,01
3,86
5,71
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,33
4,40
4,17
4,14
2,80
COP
45
1,99
2,23
2,73
3,38
5,00
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,45
4,57
4,29
4,61
3,05
COP
50
1,78
1,99
2,42
2,95
4,59
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,56
4,74
4,40
5,08
3,44
COP
55
1,60
1,79
2,16
2,62
4,07
WH-MDF16C6E5
Tamb
HC
LWC
30
-15
10,60
-7
11,90
2
13,50
7
16,00
25
16,00
IP
30
4,13
4,07
3,78
3,25
2,35
COP
30
2,57
2,92
3,57
4,92
6,81
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,42
4,30
4,00
3,78
2,73
COP
35
2,33
2,65
3,25
4,23
5,86
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,71
4,50
4,22
4,31
3,11
COP
40
2,12
2,40
2,94
3,71
5,14
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
5,00
4,70
4,44
4,84
3,49
COP
45
1,94
2,19
2,68
3,31
4,58
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,98
4,85
4,50
5,15
3,71
COP
50
1,77
1,98
2,40
2,95
4,31
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,95
4,99
4,55
5,45
3,93
COP
55
1,60
1,80
2,15
2,66
4,05
HYDRAULIC PUMP PERFORMANCE
EXTERNAL STATIC PRESSURE (kPa)
( 09C3 // 1266 // 14C6 // 16C6 )
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1
WATER FLOW RATE (L/min)
This data is measured by Panasonic in accordance with EN14511-2 standard.
This data is for reference purpose only, and does not guarantee the performance.
66
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
AQUAREA
WH-MDF09C3E8
Tamb
HC
LWC
30
8,65
-15
9,35
-7
9,31
2
9,00
7
9,00
25
IP
30
3,10
2,95
2,39
1,58
1,09
COP
30
2,79
3,17
3,90
5,70
8,26
HC
35
8,30
9,00
9,00
9,00
9,00
IP
35
3,25
3,20
2,55
1,90
1,28
COP
35
2,55
2,81
3,53
4,74
7,03
HC
40
7,95
8,85
9,00
9,00
8,73
IP
40
3,45
3,50
2,82
2,20
1,48
COP
40
2,30
2,53
3,19
4,09
5,90
HC
45
7,95
8,85
9,00
9,00
8,73
IP
45
3,45
3,50
2,82
2,20
1,48
COP
45
2,30
2,53
3,19
4,09
5,90
HC
50
7,15
8,30
8,90
9,00
8,28
IP
50
3,75
3,85
3,53
2,80
1,86
COP
50
1,91
2,16
2,52
3,21
4,45
HC
55
7,15
8,30
8,90
9,00
8,28
IP
55
3,75
3,85
3,53
2,80
1,86
COP
55
1,91
2,16
2,52
3,21
4,45
WH-MDF12C9E8
Tamb
HC
LWC
30
9,30
-15
10,40
-7
11,80
2
12,00
7
12,00
25
IP
30
3,50
3,41
3,14
2,14
1,42
COP
30
2,66
3,05
3,76
5,61
8,45
HC
35
8,90
10,00
11,40
12,00
12,00
IP
35
3,66
3,70
3,34
2,57
1,70
COP
35
2,43
2,70
3,41
4,67
7,06
HC
40
8,50
9,60
11,00
12,00
11,80
IP
40
3,83
3,90
3,57
3,00
1,98
COP
40
2,22
2,46
3,08
4,00
5,96
HC
45
8,10
9,20
10,60
12,00
11,70
IP
45
3,99
4,10
3,78
3,43
2,27
COP
45
2,03
2,24
2,80
3,50
5,15
HC
50
7,50
8,70
9,80
12,00
11,50
IP
50
4,09
4,20
3,98
3,82
2,53
COP
50
1,83
2,07
2,46
3,14
4,55
HC
55
7,00
8,20
9,10
12,00
11,40
IP
55
4,20
4,31
4,18
4,20
2,78
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MDF14C9E8
Tamb
HC
LWC
30
9,90
-15
11,10
-7
12,90
2
14,00
7
14,00
25
IP
30
3,91
3,73
3,51
2,60
1,75
COP
30
2,53
2,98
3,68
5,38
8,00
HC
35
9,50
10,70
12,40
14,00
14,00
IP
35
4,05
4,00
3,73
3,11
2,10
COP
35
2,35
2,68
3,32
4,50
6,67
HC
40
9,00
10,20
11,90
14,00
14,00
IP
40
4,19
4,20
3,95
3,63
2,45
COP
40
2,15
2,43
3,01
3,86
5,71
HC
45
8,60
9,80
11,40
14,00
14,00
IP
45
4,33
4,40
4,17
4,14
2,80
COP
45
1,99
2,23
2,73
3,38
5,00
HC
50
7,90
9,10
10,40
13,60
14,00
IP
50
4,45
4,57
4,29
4,61
3,05
COP
50
1,78
1,99
2,42
2,95
4,59
HC
55
7,30
8,50
9,50
13,30
14,00
IP
55
4,56
4,74
4,40
5,08
3,44
COP
55
1,60
1,79
2,16
2,62
4,07
WH-MDF16C9E8
Tamb
HC
LWC
30
10,60
-15
11,90
-7
13,50
2
16,00
7
16,00
25
IP
30
4,13
4,07
3,78
3,25
2,35
COP
30
2,57
2,92
3,57
4,92
6,81
HC
35
10,30
11,40
13,00
16,00
16,00
IP
35
4,42
4,30
4,00
3,78
2,73
COP
35
2,33
2,65
3,25
4,23
5,86
HC
40
10,00
10,80
12,40
16,00
16,00
IP
40
4,71
4,50
4,22
4,31
3,11
COP
40
2,12
2,40
2,94
3,71
5,14
HC
45
9,70
10,30
11,90
16,00
16,00
IP
45
5,00
4,70
4,44
4,84
3,49
COP
45
1,94
2,19
2,68
3,31
4,58
HC
50
8,80
9,60
10,80
15,20
16,00
IP
50
4,98
4,85
4,50
5,15
3,71
COP
50
1,77
1,98
2,40
2,95
4,31
HC
55
7,90
9,00
9,80
14,50
15,90
IP
55
4,95
4,99
4,55
5,45
3,93
COP
55
1,60
1,80
2,15
2,66
4,05
MONO-BLOC // HIGH-CONNECTIVITY // ON COOLING MODE // MDC
MDC
MODELS
Tamb
16
25
35
43
HC
5,90
7,45
7,00
5,80
WH-MDC09
IP
1,01
1,59
2,25
2,59
COP
5,84
4,69
3,11
2,24
HC
7,65
9,20
10,00
7,60
WH-MDC12
IP
1,30
2,30
3,60
3,95
COP
5,88
4,00
2,78
1,92
HC
8,85
10,00
11,50
9,05
WH-MDC14
IP
1,50
2,68
4,40
5,01
COP
5,90
3,73
2,61
1,81
HC
9,62
10,51
12,20
10,08
WH-MDC16
IP
1,63
2,85
4,80
5,47
COP
5,90
3,69
2,54
1,84
67
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE
MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MXF
WH-MXF09D3E5
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,88
2,45
COP
50
1,89
2,09
2,50
3,13
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-MXF12D6E5
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
11,50
12,00
12,00
12,00
13,40
IP
40
5,21
5,02
3,91
3,00
2,14
COP
40
2,21
2,39
3,07
4,00
6,26
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,42
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
10,70
12,00
12,00
12,00
12,60
IP
50
5,86
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,30
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MXF09D3E8
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,88
2,45
COP
50
1,89
2,09
2,50
3,13
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-MXF12D9E8
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
12,00
12,00
12,00
12,00
13,40
IP
40
5,45
5,02
3,91
3,00
2,14
COP
40
2,20
2,39
3,07
4,00
6,26
HC
45
12,00
12,00
12,00
12,00
13,20
IP
45
5,90
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
11,50
12,00
12,00
12,00
12,60
IP
50
6,28
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
11,10
12,00
12,00
12,00
12,00
IP
55
6,66
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
BI-BLOC // AQUAREA T-CAP // ON COOLING MODE // SXC
SXC
MODELS
Tamb
16
25
35
43
WH-SXC09 E8
HC
7,00
7,65
7,00
6,25
WH-SXC12 E8
IP
1,40
1,95
2,25
2,70
COP
5,00
3,92
3,11
2,31
HC
7,50
8,90
10,00
8,00
IP
1,45
2,20
3,60
3,05
HYDRAULIC PUMP PERFORMANCE
EXTERNAL STATIC PRESSURE (kPa)
( 09D3 // 12D6 // 12D9 // 12D3 )
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1
WATER FLOW RATE (L/min)
This data is measured by Panasonic in accordance with EN14511-2 standard.
This data is for reference purpose only, and does not guarantee the performance.
68
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
COP
5,17
4,05
2,78
2,62
AQUAREA
BI-BLOC // AQUAREA T-CAP // HEATING ONLY // SXF
WH-SXF09D3E5
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,80
2,45
COP
50
1,89
2,09
2,50
3,21
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-SXF12D3E5
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
11,50
12,00
12,00
12,00
13,40
IP
40
5,21
5,02
3,91
3,00
2,14
COP
40
2,21
2,39
3,07
4,00
6,26
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,42
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
10,70
12,00
12,00
12,00
12,60
IP
50
5,86
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,30
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
WH-SXF09D3E8
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,80
2,45
COP
50
1,89
2,09
2,50
3,21
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-SXF12D3E8
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
12,00
12,00
12,00
12,00
13,40
IP
40
5,45
5,02
3,91
3,00
2,14
COP
40
2,20
2,39
3,07
4,00
6,26
HC
45
12,00
12,00
12,00
12,00
13,20
IP
45
5,90
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
11,80
12,00
12,00
12,00
12,60
IP
50
6,28
5,94
4,90
3,82
2,70
COP
50
1,88
2,02
2,45
3,14
4,67
HC
55
11,60
12,00
12,00
12,00
12,00
IP
55
6,66
6,30
5,51
4,20
2,93
COP
55
1,74
1,90
2,18
2,86
4,10
69
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE
MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MXF
WH-MXF09D3E5
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,80
2,45
COP
50
1,89
2,09
2,50
3,21
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-MXF12D6E5
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
11,50
12,00
12,00
12,00
13,40
IP
40
5,21
5,02
3,91
3,00
2,14
COP
40
2,21
2,39
3,07
4,00
6,26
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,42
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
10,70
12,00
12,00
12,00
12,60
IP
50
5,86
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,30
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
WH-MXF09D3E8
Tamb
HC
LWC
30
9,00
-15
9,00
-7
9,00
2
9,00
7
13,60
25
IP
30
3,28
2,75
2,40
1,68
1,54
COP
30
2,74
3,27
3,75
5,36
8,83
HC
35
9,00
9,00
9,00
9,00
13,60
IP
35
3,55
3,20
2,55
1,90
1,75
COP
35
2,54
2,81
3,53
4,74
7,77
HC
40
9,00
9,00
9,00
9,00
13,20
IP
40
3,95
3,66
2,82
2,20
1,97
COP
40
2,28
2,46
3,19
4,09
6,70
HC
45
9,00
9,00
9,00
9,00
12,80
IP
45
4,34
4,11
3,09
2,50
2,18
COP
45
2,07
2,19
2,91
3,60
5,87
HC
50
9,00
9,00
9,00
9,00
12,00
IP
50
4,77
4,31
3,60
2,80
2,45
COP
50
1,89
2,09
2,50
3,21
4,90
HC
55
9,00
9,00
9,00
9,00
11,20
IP
55
5,20
4,50
4,11
3,10
2,71
COP
55
1,73
2,00
2,19
2,90
4,13
WH-MXF12D9E8
Tamb
HC
LWC
30
12,00
-15
12,00
-7
12,00
2
12,00
7
13,60
25
IP
30
4,79
3,89
3,23
2,22
1,59
COP
30
2,51
3,08
3,72
5,41
8,55
HC
35
12,00
12,00
12,00
12,00
13,60
IP
35
5,00
4,45
3,53
2,57
1,80
COP
35
2,40
2,70
3,40
4,67
7,56
HC
40
11,50
12,00
12,00
12,00
13,40
IP
40
5,21
5,02
3,91
3,00
2,14
COP
40
2,21
2,39
3,07
4,00
6,26
HC
45
11,00
12,00
12,00
12,00
13,20
IP
45
5,42
5,58
4,29
3,43
2,47
COP
45
2,03
2,15
2,80
3,50
5,34
HC
50
10,70
12,00
12,00
12,00
12,60
IP
50
5,86
5,94
4,90
3,82
2,70
COP
50
1,83
2,02
2,45
3,14
4,67
HC
55
10,50
12,00
12,00
12,00
12,00
IP
55
6,30
6,30
5,51
4,20
2,93
COP
55
1,67
1,90
2,18
2,86
4,10
MONO-BLOC // AQUAREA T-CAP // ON COOLING MODE // MXC
MXC
MODELS
Tamb
16
25
35
43
HC
7,00
7,65
7,00
6,25
WH-MXC09
IP
1,40
1,95
2,25
2,70
COP
5,00
3,92
3,11
2,31
HC
7,50
8,90
10,00
8,00
WH-MXC12
IP
1,45
2,20
3,60
3,05
HYDRAULIC PUMP PERFORMANCE
EXTERNAL STATIC PRESSURE (kPa)
( 09D3 // 12D6 // 12D3 // 12D9 )
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1
WATER FLOW RATE (L/min)
This data is measured by Panasonic in accordance with EN14511-2 standard.
This data is for reference purpose only, and does not guarantee the performance.
70
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
COP
5,17
4,05
2,78
2,62
AQUAREA
BI-BLOC // AQUAREA HT // HEATING ONLY // SHF
WH-SHF09D3E5
Tamb
LWC
-15
-7
2
7
HC
35
9
9
9
9
IP
35
3,75
3,33
2,65
1,98
COP
35
2,40
2,70
3,40
4,55
HC
45,00
8,80
8,90
9,00
9,00
IP
45,00
4,29
3,87
3,25
2,50
COP
45,00
2,05
2,30
2,77
3,60
HC
55,00
8,50
8,90
9,00
9,00
IP
55,00
4,94
4,49
3,91
3,16
COP
55,00
1,72
1,98
2,30
2,85
HC
65,00
7,80
8,90
9,00
9,00
IP
65,00
5,91
5,43
4,79
4,00
COP
65,00
1,32
1,64
1,88
2,25
WH-SHF12D6E5
Tamb
LWC
-15
-7
2
7
HC
30
9
9
9
9
IP
30
3,75
3,33
2,65
1,98
COP
30
2,40
2,70
3,40
4,55
HC
35
8,80
8,90
9,00
9,00
IP
35
4,29
3,87
3,25
2,50
COP
35
2,05
2,30
2,77
3,60
HC
40
8,50
8,90
9,00
9,00
IP
40
4,94
4,49
3,91
3,16
COP
40
1,72
1,98
2,30
2,85
HC
45
7,80
8,90
9,00
9,00
IP
45
5,91
5,43
4,79
4,00
COP
45
1,32
1,64
1,88
2,25
WH-SHF09D3E8
Tamb
LWC
-15
-7
2
7
HC
35
9
9
9
9
IP
35
3,75
3,33
2,65
1,98
COP
35
2,40
2,70
3,40
4,55
HC
45,00
8,80
8,90
9,00
9,00
IP
45,00
4,29
3,87
3,25
2,50
COP
45,00
2,05
2,30
2,77
3,60
HC
55,00
8,50
8,90
9,00
9,00
IP
55,00
4,94
4,49
3,91
3,16
COP
55,00
1,72
1,98
2,30
2,85
HC
65,00
7,80
8,90
9,00
9,00
IP
65,00
5,91
5,43
4,79
4,00
COP
65,00
1,32
1,64
1,88
2,25
WH-SHF12D9E8
Tamb
LWC
-15
-7
2
7
HC
30
9
9
9
9
IP
30
3,75
3,33
2,65
1,98
COP
30
2,40
2,70
3,40
4,55
HC
35
8,80
8,90
9,00
9,00
IP
35
4,29
3,87
3,25
2,50
COP
35
2,05
2,30
2,77
3,60
HC
40
8,50
8,90
9,00
9,00
IP
40
4,94
4,49
3,91
3,16
COP
40
1,72
1,98
2,30
2,85
HC
45
7,80
8,90
9,00
9,00
IP
45
5,91
5,43
4,79
4,00
COP
45
1,32
1,64
1,88
2,25
71
HEATING CAPACITY TABLE BASED ON OUTLET TEMPERATURE AND OUTSIDE TEMPERATURE
MONO-BLOC // AQUAREA T-CAP // HEATING ONLY // MHF
WH-MHF09D3E5
Tamb
LWC
-15
-7
2
7
HC
35
9
9
9
9
IP
35
3,75
3,33
2,65
1,98
COP
35
2,40
2,70
3,40
4,55
HC
45,00
8,80
8,90
9,00
9,00
IP
45,00
4,29
3,87
3,25
2,50
COP
45,00
2,05
2,30
2,77
3,60
HC
55,00
8,50
8,90
9,00
9,00
IP
55,00
4,94
4,49
3,91
3,16
COP
55,00
1,72
1,98
2,30
2,85
HC
65,00
7,80
8,90
9,00
9,00
IP
65,00
5,91
5,43
4,79
4,00
COP
65,00
1,32
1,64
1,88
2,25
WH-MHF12D6E5
Tamb
LWC
-15
-7
2
7
HC
35
12
12
12
12
IP
35
5,58
4,80
3,72
2,73
COP
35
2,15
2,50
3,23
4,40
HC
45,00
10,80
11,20
11,30
12,00
IP
45,00
5,54
5,09
4,19
3,48
COP
45,00
1,95
2,20
2,70
3,45
HC
55,00
9,70
10,10
10,80
12,00
IP
55,00
5,81
5,32
4,91
4,32
COP
55,00
1,67
1,90
2,20
2,78
HC
65,00
8,00
9,60
10,30
12,00
IP
65,00
6,15
5,96
5,63
5,45
COP
65,00
1,30
1,61
1,83
2,20
WH-MHF09D3E8
Tamb
LWC
-15
-7
2
7
HC
35
9
9
9
9
IP
35
3,75
3,33
2,65
1,98
COP
35
2,40
2,70
3,40
4,55
HC
45,00
8,80
8,90
9,00
9,00
IP
45,00
4,29
3,87
3,25
2,50
COP
45,00
2,05
2,30
2,77
3,60
HC
55,00
8,50
8,90
9,00
9,00
IP
55,00
4,94
4,49
3,91
3,16
COP
55,00
1,72
1,98
2,30
2,85
HC
65,00
7,80
8,90
9,00
9,00
IP
65,00
5,91
5,43
4,79
4,00
COP
65,00
1,32
1,64
1,88
2,25
WH-MHF12D9E8
Tamb
LWC
-15
-7
2
7
HC
35
12
12
12
12
IP
35
5,58
4,80
3,72
2,73
COP
35
2,15
2,50
3,23
4,40
HC
45,00
10,80
11,20
11,30
12,00
IP
45,00
5,54
5,09
4,19
3,48
COP
45,00
1,95
2,20
2,70
3,45
HC
55,00
9,70
10,10
10,80
12,00
IP
55,00
5,81
5,32
4,91
4,32
COP
55,00
1,67
1,90
2,20
2,78
HC
65,00
8,00
9,60
10,30
12,00
IP
65,00
6,15
5,96
5,63
5,45
COP
65,00
1,30
1,61
1,83
2,20
HYDRAULIC PUMP PERFORMANCE
EXTERNAL STATIC PRESSURE (kPa)
( 09D3 // 12D6 // 12D9 )
PUMP SPEED 3
PUMP SPEED 2
PUMP SPEED 1
WATER FLOW RATE (L/min)
This data is measured by Panasonic in accordance with EN14511-2 standard.
This data is for reference purpose only, and does not guarantee the performance.
72
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
AQUAREA
AQUAREA PRO // ECOi + U-250WX2E5 // HEATING
MDC
Tamb
LWC
-15
-7
2
7
25
HC
30
IP
30
COP
30
HC
35
IP
35
COP
35
HC
40
22,90
25,80
31,40
31,50
31,50
IP
40
9,76
10,3
11,0
9,75
6,83
COP
40
2,34
2,50
2,85
3,23
4,61
HC
45
20,70
23,40
28,00
28,00
28,00
IP
45
8,83
9,26
9,64
8,61
6,06
COP
45
2,34
2,52
2,90
3,25
4,62
HC
50
IP
50
COP
50
HC
55
IP
55
COP
55
HC
40
42,40
48,00
56,00
56,00
56,00
IP
40
19,4
20,5
21,0
18,1
12,8
COP
40
2,18
2,34
2,66
3,09
4,37
HC
45
39,30
44,90
51,30
51,30
51,30
IP
45
17,5
18,5
18,4
16,5
11,5
COP
45
2,24
2,42
2,78
3,10
4,46
HC
50
IP
50
COP
50
HC
55
IP
55
COP
55
AQUAREA PRO // ECOi + U-500WX2E5 // HEATING
MDC
Tamb
LWC
-15
-7
2
7
25
HC
30
IP
30
COP
30
HC
35
IP
35
COP
35
73
ACCESSORIES
THIRD PARTY TANKS
FIELD PROCURED OPTIONAL PARTS
High Efficiency Tank
Water volume
Max. water temperature
Dimension. High
Diameter
Weight
Electric heater
Power supply
Material inside tank
Exchange surface
Energy loss at 65°C insulated
tested under EN12897
3 Way valve included
HR 200*
200
95
1340
600
108
3
230V
enamelled
1,80
m2
kWh/24h 1,8
L
°C
mm
mm
kg
kW
YES
Super High Efficiency Tank
HR 300*
300
95
1797
600
140
3
230V
enamelled
2,60
2,2
HRS 300*
300
95
1435
680
170
3
230V
enamelled
3,50
2,2
HRS 500*
500
95
1806
760
254
3
230V
enamelled
6,00
2,7
YES
YES
YES
SOLAR KIT
Brand
Model No.
RESOL
FlowConS_DeltaSol_BS_Plus
Oventrop
Regusol X-25
3 WAY-VALVE
Brand
Model No.
Siemens
SFA21/18 / VXI46/25
2 WAY VALVE
Brand
Model No.
Honeywell
V4043C1007
Siemens
SFA21/18 // VVI46/25
ROOM THERMOSTAT ON / OFF
Brand
Model No.
Siemens
RAA20
Siemens
REV200
THERMAL VALVE
Brand
Model No.
Taconova
RA57
Danfoss
AVB-NC
Feature
Remote Control
Remote Control
Feature
Spring return
Feature
Spring return
Spring return
Feature
Dial type
Programme
Feature
NC
NC
PANASONIC ACCESSORIES
SOLAR KIT ACCESSORIES
CZ-NS1P
Solar connection PCB (for Bi-split type)
CZ-NS3P
Solar connection PCB (for Mono-bloc type)
CZ-NS2P
Solar connection PCB (for Mono-bloc)
SANITARY TANK ACCESSORIES
CZ-TK1
Temperature sensor kit for third party tank
CZ-TK3
Temperature sensor kit for third party tank for mini Monobloc
DEICE ACCESSORIES
CZ-NE1P
Base pan heater kit
RESOL
FlowConS_DeltaSol_
BS_Plus
HR200*
HRS300*
Danfoss
AVB-NC
HR300*
HRS500*
* Panasonic’s term of warranty is based on the warranty conditions provided by the tank supplier being met. Please ensure the maintenance
programme is carried out as instructed in the tank manufacturer’s manual.
74
Oventrop
REGSOL UNO X-15
Siemens
REV200
Taconova
RA57
SIEMENS. 2-way valve
Morter : SFA21/18
Valve body : VVI46/25
Siemens
RAA20
SIEMENS. 3-way valve
Morter : SFA21/18
valve body : VXI46/25
AQUAREA
THE OPERATION LED BLINKS AND AN ERROR CODE APPEARS ON THE
CONTROL PANEL DISPLAY.
FORCE HEATER MODE BUTTON
· The backup heater also serves as backup in case of malfunctioning of the
outdoor unit.
· Turn the unit off and inform the authorised dealer of the error
· Press
to stop the force heater operation.
code.
· During Force Heater mode, all other operations are not allowed.
· The timer operation is cancelled when an error code occurs.
ERROR CODES TABLE
Diagnosis display
H00
H12
Abnormality / Protection control
No abnormality detected
Indoor/Outdoor capacity unmatched
Abnormality Judgement
—
90s after power supply
H15
H23
H38
H42
Outdoor compressor temperature sensor abnormality
Indoor refrigerant liquid temperature sensor abnormality
Indoor/Outdoor mismatch
Compressor low pressure abnormality
Continue for 5 sec.
Continue for 5 sec.
—
—
H62
H64
H70
H72
H76
H90
Water flow switch abnormality
Refrigerant high pressure abnormality
Back-up heater OLP abnormality
Tank sensor abnormal
Indoor - control panel communication abnormality
Indoor / outdoor abnormal communication
Continue for 1 min.
Continue for 5 sec.
Continue for 60 sec.
Continue for 5 sec.
—
> 1 min after starting operation
H91
H95
H98
Tank heater OLP abnormality
Indoor/Outdoor wrong connection
Outdoor high pressure overload protection
Continue for 60 sec.
—
—
H99
Indoor heat exchanger freeze prevention
—
F12
F14
F15
Pressure switch activate
Outdoor compressor abnormal revolution
Outdoor fan motor lock abnormality
4 times occurrence within 20 minutes
4 times occurrence within 20 minutes
2 times occurrence within 30 minutes
F16
Total running current protection
3 times occurrence within 20 minutes
F20
Outdoor compressor overheating protection
4 times occurrence within 30 minutes
F22
IPM (power transistor) overheating protection
3 times occurrence within 30 minutes
F23
Outdoor Direct Current (DC) peak detection
7 times occurrence continuously
F24
Refrigeration cycle abnormality
2 times occurrence within 20 minutes
F25
Cooling / Heating cycle changeover abnormality
4 times occurrence within 30 minutes
F27
F36
F37
F40
F41
F42
F43
F45
F46
Pressure switch abnormality
Outdoor air temperature sensor abnormality
Indoor water inlet temperature sensor abnormality
Outdoor discharge pipe temperature sensor abnormality
PFC control
Outdoor heat exchanger temperature sensor abnormality
Outdoor defrost sensor abnormality
Indoor water outlet temperature sensor abnormality
Outdoor Current Transformer open circuit
Continue for 1 min.
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
4 times occurrence within 10 minutes
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
—
F95
Cooling high pressure overload protection
—
Primary location to verify
—
· Indoor/outdoor connection wire
· Indoor/outdoor PCB
· Specification and combination table in catalogue
· Compressor temperature sensor (defective or disconnected)
· Refrigerant liquid temperature sensor (defective or disconnected)
· Indoor/Outdoor PCB
· Outdoor pipe temperature sensor
· Clogged expansion valve or strainer
· Insufficient refrigerant
· Outdoor PCB
· Compressor
· Water flow switch
· Outdoor high pressure sensor (defective or disconnected)
· Back-up heater OLP (Disconnection or activated)
· Tank sensor
· Indoor - control panel (defective or disconnected)
· Internal / external cable connections
· Indoor / Outdoor PCB
· Tank heater OLP (Disconnection or activated)
· Indoor/Outdoor supply voltage
· Outdoor high pressure sensor
· Water pump or water leakage
· Clogged expansion valve or strainer
· Excess refrigerant
· Outdoor PCB
· Indoor heat exchanger
· Refrigerant shortage
· Pressure switch
· Outdoor compressor
· Outdoor PCB
· Outdoor fan motor
· Excess refrigerant
· Outdoor PCB
· Compressor tank temperature sensor
· Clogged expansion valve or strainer
· Insufficient refrigerant
· Outdoor PCB
· Compressor
· Improper heat exchange
· IPM (Power transistor)
· Outdoor PCB
· Compressor
· Insufficient refrigerant
· Outdoor PCB
· Compressor low compression
· 4-way valve
· V-coil
· Pressure switch
· Outdoor air temperature sensor (defective or disconnected)
· Water inlet temperature sensor (defective or disconnected)
· Outdoor discharge pipe temperature sensor (defective or disconnected)
· Voltage at PFC
· Outdoor heat exchanger temperature sensor (defective or disconnected)
· Outdoor defrost sensor (defective or disconnected)
· Water outlet temperature sensor (defective or disconnected)
· Insufficient refrigerant
· Outdoor PCB
· Compressor low
· Outdoor high pressure sensor
· Water pump or water leakage
· Clogged expansion valve or strainer
· Excess refrigerant
· Outdoor PCB
75
www.panasonic.eu
To find out how Panasonic cares for you,
log on to: www.panasonic.eu
Contact Details:
Telephone: 01344 853182
www.panasonic.co.uk/aircon
Address: Panasonic Air Conditioning
Panasonic House
Willoughby Road
Bracknell
Berkshire
RG12 8FP
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer
without prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd.
www.eggeassociats.net
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement