Omron SYSMAC CXONE-AL**C-E Setup Manual

Add to my manuals
51 Pages

advertisement

Omron SYSMAC CXONE-AL**C-E Setup Manual | Manualzz

Cat. No. W444-E1-02

SYSMAC

CXONE-AL@

@C-E

CX-One Ver. 1.1

FA Integrated Tool Package

SETUP MANUAL

CXONE-AL

@@C-E

CX-One Ver. 1.1

FA Integrated Tool Package

Setup Manual

Revised November 2005

iv

Notice:

OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.

The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property.

!DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Additionally, there may be severe property damage.

!WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Additionally, there may be severe property damage.

!Caution

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury, or property damage.

OMRON Product References

All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product.

The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means

“word” and is abbreviated “Wd” in documentation in this sense.

The abbreviation “PLC” means Programmable Controller. “PC” is used, however, in some Programming Device displays to mean Programmable Controller.

Visual Aids

The following headings appear in the left column of the manual to help you locate different types of information.

Note Indicates information of particular interest for efficient and convenient operation of the product.

1,2,3...

1.

Indicates lists of one sort or another, such as procedures, checklists, etc.

OMRON, 2005

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of

OMRON.

No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.

v

vi

TABLE OF CONTENTS

PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xv

1 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xvi

2 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xvi

SECTION 1

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1-1 Overview of CX-One. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1-2 Confirmation of CX-One Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-3 Support Software in CX-One. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-4 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

5

8

SECTION 2

Installation and Uninstallation . . . . . . . . . . . . . . . . . . . . . . .

11

2-1 Installing the CX-One . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

2-2 CX-One Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

vii

viii

TABLE OF CONTENTS

About this Manual:

This manual describes the installation and operation of the CX-One FA Integrated Tool Package and includes the sections described below.

Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the CX-One. Be sure to read the precautions provided in the following section.

Precautions provides general precautions for using the CX-One.

Section 1 provides an overview of the CX-One FA Integrated Tool Package, its contents, and system requirements.

Section 2 describes how to install and uninstall the software provided in the CX-One.

!WARNING

Failure to read and understand the information provided in this manual may result in personal injury or death, damage to the product, or product failure. Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given.

ix

x

Version Upgrade Information:

The following have been changed in upgrading the CX-One from version 1.0 to version 1.1.

Item

Hardware space required to install all of the CX-One software

Number of setup disks (CD-ROM)

Software installed for the CX-One

New software added to the CX-One

Ver. 1.0

Approx. 1.6 GB Approx. 1.8 GB

2 disks

CX-Programmer Ver. 6.0

CX-Integrator Ver. 1.0

CX-Simulator

NS-Designer

Ver. 1.5

Ver. 6.2

CX-Motion Ver. 2.2

CX-Motion-NCF Ver. 1.2

CX-Position

CX-Thermo

Ver. 2.1

Ver. 2.0

CX-Protocol Ver. 1.6

CX-Process Tool Ver. 4.1

CX-Server Ver. 2.3

SwitchBox Utility Ver. 1.6

CX-Motion-MCH ---

CX-Drive

CX-FLnet

CX-Profibus

---

---

---

3 disks

Ver. 1.1

Ver. 6.1

Ver. 1.1

Ver. 1.6

CX-Designer Ver. 1.0

Ver. 2.22

Ver. 1.3

Ver. 2.2

Ver. 2.01

Ver. 1.61

Ver. 5.0

Ver. 2.4

Ver. 1.61

Ver. 1.0

Ver. 1.1

Ver. 1.0

Ver. 1.0

Refer to 1-3-1 Support Soft-

ware in CX-One and Refer-

ence Manuals for details.

Read and Understand this Manual

Please read and understand this manual before using the product. Please consult your OMRON representative if you have any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-

INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE

PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS

DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR

INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT

LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS

REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS

WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO

CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

xi

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this manual.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR

PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO

ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

xii

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and

Limitations of Liability.

ERRORS AND OMISSIONS

The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.

xiii

xiv

PRECAUTIONS

This section provides general precautions for using the CX-One FA Integrated Tool Package.

The information contained in this section is important for the safe and reliable application of the CX-One FA

Integrated Tool Package. You must read this section and understand the information contained before attempting to set up or operate the CX-One FA Integrated Tool Package.

1

2

Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi xvi

xv

Intended Audience

1

2

1

Intended Audience

This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent).

• Personnel in charge of installing FA systems.

• Personnel in charge of designing FA systems.

• Personnel in charge of managing FA systems and facilities.

Safety Precautions

!Caution When performing any of the following operations, always check the network address and node address of the other node (PLC) and the node address and unit number of the mounted Unit (PLC CPU Bus Unit or Special I/O Unit) or the node address of the Component (DeviceNet Master/Slave or Compo-

Way/F Slave), and be sure that these operations can be performed safely for the current status of the node (Unit or Component):

• Transferring parameter or program data to the other node

• Changing the operating mode of the other node

Unexpected operation may result if parameter or program data is transferred to the wrong node (DeviceNet Master/Slave or CompoWay/F Slave), the operating mode of the wrong node is changed, or the other node is not in a suitable status to receive the program or parameter data or the operating mode change.

!Caution Particularly when changing the target PLC to any PLC other than the relay

PLC, check the node address and node number of the target PLC carefully before executing the change.) Unexpected operation and injury may result if the wrong PLC is set as the target PLC.

Note

• Changing the operating mode

• Transferring or verifying user-set data link tables

• Transferring or verifying routing tables

• Performing I/O table operations (including transferring CPU Bus Unit or

Special I/O Unit parameters)

Operations performed from the CX-Integrator are performed for the target

PLC, which is not necessarily the same as the relay PLC.

!Caution When transferring parameters that have been created or edited on the computer to actual Units (PLC CPU Bus Units or PLC Special I/O Units) or to actual components (DeviceNet Masters/Slaves or CompoWay/F Slaves), or when resetting Units mounted on other PLC nodes or components (DeviceNet

Masters/Slaves or CompoWay/F Slaves) connected via communications with other PLC nodes, always check the identifying numbers of the actual Units or

Components (i.e., the unit numbers and unit addresses or node addresses) before executing the transfer or reset. Unexpected operation and injury may result if parameters are transferred to the wrong Unit or components, or the wrong Unit or component is reset.

xvi

Safety Precautions

2

Observe the following precautions when using the CX-One.

• When saving or opening a project file, always confirm the location of the folder and the file name before executing the save or open. The CX-One automatically switches the folder when saving and opening.

• Before changing the operating mode, always confirm that doing so will not adversely affect system operation.

• Always check the operation of programs and parameters sufficiently before using them for actual system operation.

• Confirm that resetting CPU Bus Units, Special I/O Units, and DeviceNet

Master/Slave Units will not adversely affect system operation before resetting these Units.

xvii

Safety Precautions

2 xviii

SECTION 1

Overview

This section provides an overview of the CX-One FA Integrated Tool Package, its contents, and system requirements.

1-1 Overview of CX-One . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-1-1 The CX-One FA Integrated Tool Package . . . . . . . . . . . . . . . . . . . .

1-1-2 CX-One Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-2 Confirmation of CX-One Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . .

1-2-1 Confirmation of CX-One Package Contents . . . . . . . . . . . . . . . . . .

1-2-2 User Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-3 Support Software in CX-One . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-3-1 Support Software in CX-One and Reference Manuals. . . . . . . . . . .

1-3-2 Starting Support Software in CX-One . . . . . . . . . . . . . . . . . . . . . . .

1-4 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-4-1 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1-4-2 Hard Disk Space Requirements for Support Software in CX-One. .

2

2

2

3

3

4

5

5

7

8

8

9

1

Overview of CX-One

Section 1-1

1-1 Overview of CX-One

1-1-1 The CX-One FA Integrated Tool Package

The CX-One FA Integrated Tool Package integrates all of the Support Software for OMRON PLCs and Components. Although previously it was necessary to purchase, install, run, and connect online to the PLC separately for the

Support Software for each Unit, the CX-One now provides an integrated development environment based on the CPS (Component and Network Profile Sheet) for each OMRON Unit or Component. If the CX-One is installed in a single computer, an integrated operating environment can be used all the way from setting OMRON PLC Units through system startup and monitoring to greatly increase system setup efficiency.

1-1-2 CX-One Features

Integrated Software

Management for OMRON

PLCs and Components

Support Software for CPU

Bus Units and Special I/O

Units can be started from the I/O tables.

• One computer with the CX-One installed provides the Support Software required to handle any OMRON product.

• All of the Support Software can be installed with a single license.

• Files saved from the various Support Software can be centrally managed in one location.

When Support Software is started from the I/O tables (i.e., the Unit Configuration Table registered in the PLC), PLC and Unit settings can be inherited so that they do not have to be re-entered every time Support Software is started.

Component and Network

Profile Sheets (CPS)

Note

• CPU Bus Units and Special I/O Units can be set without concern for memory addresses and without relying on operation manuals. Parameter names, selections, and setting ranges are automatically displayed.

• Online, settings for virtual Units on the computer can be compared to the settings in the actual Units, with any differences displayed in orange in the comparison results.

• The Unit configuration in I/O tables is displayed using Unit model numbers.

• Model and unit version checks can be performed when transferring data to actual Units.

• Device types on the network can be confirmed using Unit models.

Component and Network Profile Sheet (CPS) files contain CS/CJ-series Unit definitions or Component definitions within the CX-One. CPS files are provided in XML format. The CX-One uses CPS files to recognize CS/CJ-series

Units. Settings for CPU Bus Units and Special I/O Units are also created based on CPS files.

2

Confirmation of CX-One Package Contents

Section 1-2

1-2 Confirmation of CX-One Package Contents

1-2-1 Confirmation of CX-One Package Contents

CX-One Model Number and Contents

Name

CX-One FA Integrated

Tool Package

Ver. 1.1

(CX-One Ver. 1.1)

Model Installable Support Software

CXONE-AL

@@C-E CX-Programmer

CX-Integrator

CX-Simulator

CX-Designer

Ver. 6.1

Ver. 1.1

Ver. 1.6

Ver. 1.0

Other included data

• OMRON Function Blocks (FB)

• Smart Active Parts (Smart Active Parts)

• CPS files

• Manual (PDF)

CX-Motion

CX-Motion-NCF

Ver. 2.2

Ver. 1.3

CX-Motion-MCH

CX-Position

CX-Drive

CX-Protocol

Ver. 1.0

Ver. 2.2

Ver. 1.1

Ver. 1.6

CX-Process Tool

CX-Profibus

Ver. 5.0

Ver. 1.0

Faceplate Auto-Builder for NS Ver. 2.0

CX-Thermo Ver. 2.0

CX-FLnet

CX-Server

SwitchBox Utility

Ver. 1.0

Ver. 2.4

Ver. 1.6

CX-One Contents

The contents of CX-One are listed in the following table. Please confirm that you have received everything.

CXONE-AL @@C-E CX-One FA Integrated Tool Package

Installation Disks (CD-ROM)

CX-One Introduction Guide (Cat. No. R135)

CX-Programmer Introduction Guide (Cat. No. R132)

CX-Designer Introduction Guide (Cat. No. V089)

Function Block Introduction Guide (Cat. No. R133)

CX-One Setup Manual (Cat. No. W444) (this manual)

CX-Programmer Operation Manual (Cat. No. W446)

CX-Programmer Operation Manual: Function Blocks (Cat. No. W447)

CX-Integrator Operation Manual (Cat. No. W445)

CX-Simulator Operation Manual (Cat. No. W366)

CX-Designer User’s Manual (Cat. No. V088)

CX-Motion-NCF Operation Manual (Cat. No. W436)

CX-Motion-MCH Operation Manual (Cat. No. W448)

CX-Position Operation Manual (Cat. No. W433)

CX-Drive Operation Manual (Cat. No. W453)

CX-Protocol Operation Manual (Cat. No. W344)

CX-Profibus Operation Manual (Cat. No. W05E-EN)

CX-Process Tool Software Operation Manual (Cat. No. W372)

Faceplate Auto-Builder for NS Operation Manual (Cat. No. W418)

Smart Function Blocks Reference Manual (Cat. No. W442)

Smart Active Parts Reference Manual (See note. )

CX-Thermo Operation Manual

Software License Agreement/User Registration Card

3 disks

Printed manuals and PDF manuals in the CD-ROM

PDF manuals in the CD-ROM

(Only the main manuals are listed.)

Online help only

1

Note

PDF manuals are provided for each Unit.

3

Confirmation of CX-One Package Contents

FA Integrated Tool Package

CX-One Introduction Guide

Section 1-2

Software License Agreement

User Registration Card

The license number is printed on the cover.

Model number, license number, and number of licenses are printed on the card.

Note

The license number required for installation is printed on the Software License

Agreement/User Registration Card. Place this card in a safe place and be sure not to loose the license number.

1-2-2 User Registration

Always perform user registration before using the CX-One.

Online User Registration (Internet Connection Required)

Registering from the Online Registration Dialog Box

1,2,3...

1.

The following Online Registration Dialog Box will be displayed after when computer is restarted upon completion of CX-One installation.

Note

2.

Click the Register Button. A wizard will connect you to the OMRON CX-

One website. (See note.)

Note

If the Exit Button is clicked to cancel online registration, the Online

Registration Dialog Box will be displayed every time Support Software in CX-One is started.

3.

Enter the information required for user registration according to the site windows. Use the product key and license number given on the Software

License Agreement/User Registration Card provided with the CX-One.

4.

After completion of registration, registration confirmation will be sent to the email address input during the registration procedure.

The Online Registration Dialog Box will be displayed even if online registration has already been completed. If this happen, select the Do not display this dia-

log again option and click the Exit Button. Also use this procedure in the following cases.

• The Windows login name is different from the registered name.

• User registration was performed using the User Registration Postcard.

4

Support Software in CX-One

Online Registration from the CX-Programmer or other Support Software in

CX-One

Using the User

Note

Registration Postcard

Note

Section 1-3

OMRON's CX-One website will be displayed if Help - Online Registration is selected from the menu bar of CX-Programmer or other Support Software in

CX-One. Enter the information required for user registration according to the site windows. Use the product key and license number given on the Software

License Agreement/User Registration Card provided with the CX-One.

Do not register more than once. For example, if you're returned the card, do not register online.

Enter the required information on the User Registration Postcard provided with the CX-One and send the card.

Approximately two weeks will be required from the time the User Registration

Postcard is posted until confirmation of registration is returned to you. Downloading OMRON Standard Libraries and other operations allowed only for registered users will not be possible during this period.

1-3 Support Software in CX-One

1-3-1 Support Software in CX-One and Reference Manuals

The following tables lists the Support Software that can be installed from CX-

One along with the startup methods and the reference manuals for each.

Support Software in CX-One

CX-Programmer

CX-Integrator

Switch Box Utility

CX-Protocol

CX-Simulator

CX-Position

CX-Motion-NCF

Outline

Application software to create and debug programs for SYSMAC CS/CJ/CP-series,

C-series, and CVM1/C-series CPU Units.

Startup method within

CX-One

Started from a PLC in the

CX-Integrator Network

Configuration Window.

Documentation

(PDF manuals provided in CD-ROM)

CX-Programmer Operation Manual (Cat. No.

W446)

CX-Programmer Operation Manual: Function

Blocks (Cat. No. W447)

CX-Integrator Operation

Manual (Cat. No. W445)

Application software to build and set up FA networks, such as Controller Link,

DeviceNet, and CompoWay/F networks.

The Routing Table Component and Data

Link Component can be started from here.

DeviceNet Configuration functionality is also included.

Started by selecting

Tools - Network Set-

tings from the CX-Programmer menu bar or from a CPU Unit in the

CX-Programmer I/O tables.

Started from the CX-Programmer Tools Menu.

Utility software that helps you to debug

PLCs. It helps you to monitor the I/O status and to monitor/change present values within the PLC you specify.

Application software to create protocols

(communications sequences) between

SYSMAC CS/CJ-series or C200HX/HG/HE

Serial Communications Boards/Units and general-purpose external devices.

Application software to simulate SYSMAC

CS/CJ/CP-series CPU Unit operation on the computer to debug PLC programs without a CPU Unit.

Started from a Serial

Communications Board or Unit in the CX-Programmer I/O tables.

---

Online Help

CX-Protocol Operation

Manual (Cat. No. W344)

CX-Simulator Operation

Manual (Cat. No. W366)

Application software to create and monitor data for SYSMAC CS/CJ-series Position

Control Units.

Application software to monitor and set parameters for SYSMAC CJ-series Position Control Units and Servo Drivers that support MECHATROLINK-II communications.

Started from a Position

Control Unit in the CX-

Programmer I/O tables.

Started from an NCF

Position Control Unit in the CX-Programmer I/O tables.

CX-Position Operation

Manual (Cat. No. W433)

CX-Motion-NCF Operation Manual (Cat. No.

W436)

5

Support Software in CX-One

Section 1-3

Support Software in CX-One

CX-Motion-MCH

CX-Motion

CX-Drive

CX-Process Tool

Faceplate Auto-

Builder for NS

CX-Designer

CX-Profibus

CX-Thermo

CX-FLnet

CX-Server

PLC Tools (Installed automatically.)

Outline

Application software to create data for SYS-

MAC CS/CJ-series MCH Units, create motion programs, and perform monitoring.

Application software to create data for SYS-

MAC CS/CJ-series, C200HX/HG/HE, and

CVM1/CV-series Motion Control Units, and to create and monitor motion control programs.

Application software to set and control data for Inverters and Servos.

Startup method within

CX-One

Started from a Motion

Control (MCH) Unit in the

CX-Programmer I/O tables.

Started from a Motion

Control Unit in the CX-

Programmer I/O tables.

Documentation

(PDF manuals provided in CD-ROM)

CX-Motion-MCH Operation Manual (Cat. No.

W448)

---

CX-Drive Operation Manual (Cat. No. W453)

Started from an Inverter or Servo in the CX-Integrator Network Configuration Window.

Started from a Loop Controller in the CX-Programmer I/O tables.

CX-Process Tool Operation Manual (Cat. No.

W372)

Application software to create and debug function block programs for SYSMAC

CS/CJ-series Loop Controllers (Loop Control Units/Boards, Process Control CPU

Units, and Loop Control CPU Units).

Application software that automatically outputs screen data as project files for NSseries PTs from tag information in function block programs created with the CX-Process Tool.

Faceplate Auto-Builder for NS Operation Manual

(Cat. No. W418)

Application software to create screen data for NS-series PTs.

Application software for setting the PROFI-

BUS master.

Application software to set and control parameters in components such as Temperature Control Units.

Application software for system setting and monitoring of SYSMAC CS/CJ-series FLnet

Units

Middleware necessary for CX-One applications to communicate with OMRON components, such, such as PLCs, Display

Devices, and Temperature Control Units.

A group of components used with CX-One applications, such as the CX-Programmer and CX-Integrator. Includes the following:

I/O tables, PLC memory, PLC Setup, Data

Tracing/Time Chart Monitoring, PLC Error

Logs, File Memory, PLC clock, Routing

Tables, and Data Link Tables.

Started by selecting Exe-

cute - Create Tag File -

Start NSFP from the CX-

Process Tool menu bar

(starts automatically after execution of the CSV tag compiler).

Started from a NS-series

PT in the CX-Integrator

Network Configuration

Window.

Started from a PROFI-

BUS-DP Unit in the CX-

Programmer I/O tables

Started from a E5

@R,

E5

@N, or E5ZN Temperature Control Unit in the

CX-Integrator Network

Configuration Window.

Started from a FLnet Unit in the CX-Programmer

I/O tables.

---

Components are started from the various Support

Software.

CX-Designer User’s Manual (V088)

CX-Profibus Operation

Manual (Cat. No. W05E-

EN)

Online Help

---

---

Refer to documentation of individual Support

Software.

6

Support Software in CX-One

Section 1-3

1-3-2 Starting Support Software in CX-One

Support Software in CX-One can be started from the I/O tables in the CX-Programmer, from the Network Configuration Window in the CX-Integrator, or from the Tools Menus as shown in the following diagram. This is called the

Specialized Support Tool startup function and it is enabled when the CX-Programmer and other Support Software is installed from the CX-One.

CX-Protocol

CX-Position

CX-Motion-NCF

CX-Motion

CX-Process Tool

Faceplate Auto-

Builder for NS

CX-Profibus

CX-FLnet

Switch Box Utility

CX-One Startup Diagram

CX-Programmer

I/O Table Window

CS/CJ-series CPU Unit

CPU Rack

Ethernet Unit

(CS1W/CJ1W-ETN @@)

Controller Link Unit

(CS1W/CJ1W-CLK @@)

SYSMAC LINK Unit

(CS1W-SLK @@)

DeviceNet Unit

(CS1W/CJ1W-DRM @@)

Start with Settings

Inherited

Start with Settings

Inherited

Start with Settings

Inherited

CX-Integrator

Network Configuration Window

CS/CJ-series CPU Unit

Ethernet, Controller Link, or SYSMAC LINK

Started with Settings

Inherited

CX-Drive

DeviceNet

Start with Settings

Inherited

Select CX-Protocol.

Serial Communications

Board/Unit

(CS1W-SCB @@)

(CS1W/CJ1W-SCU @@)

Start with Settings

Inherited Position Control Unit

(CS1W/CJ1W-NC @@@)

Start with Settings

Inherited

Position Control Unit with MECHA-

TROLINK-II Communications

(CJ1W-NCF @@)

Start with Settings

Inherited

Motion Control Unit

(CS1W-MC @@@)

Start with Settings

Inherited

Loop Control Unit/Board

(CS1W-LC001/LCB @@)

Loop Control CPU Unit

(CJ1G-CPU @@P)

Process Control CPU Unit

(CS1D-CPU @@P)

Start with Settings

Inherited PROFIBUS-DP

Master Unit

(CJ1W-PRM @@)

Start with Settings

Inherited

FL-net Unit

(CS1W/CJ1W-FLN

@@)

Start with Settings

Inherited

Select CX-Integrator.

Select Tools - Network Settings.

Select Tools - Switch Box Utility.

NS-series PC (-V1)

NT Link

E5 @@ Temperature

Controller

CompoWay/F

Start with Settings

Inherited

Start with Settings

Inherited

CX-Designer

CX-Thermo

Select Tools - Start Routing Table from the menu bar or right-click Network Communications Unit in Online

Connection Information Window and select Start Rout-

ing Table from the pop-up menu.

Select Tools - Start Data Link from the menu bar or right-click Controller Link or SYSMAC LINK Unit in Online Connection Information Window and select Start

Data Link from the pop-up menu.

Routing Table

Component

Data Link

Component

7

System Requirements

Starting while Inheriting

Settings

Starting with or without

Inheriting Settings

Section 1-4

• Setting the device type is not required every time different Support Software is started.

• The online connection is also inherited by the newly opened Support Software.

• New project files are automatically created for the newly opened Support

Software.

If Open - Save As is selected after starting Support Software, the save to folder will be the same as the one used with the CX-Programmer.

1-4 System Requirements

1-4-1 System Requirements

The system requirements for the CX-One are given in the following table.

Item

Operating system (OS)

(See note 1.)

Japanese or English system

Computer

Memory

Hard disk

Display

Disk drive

Communications ports

Other

Microsoft Windows

98SE

Requirement

Microsoft Windows

NT (Service Pack 6a)

Microsoft Windows

2000 (Service Pack 3 or higher) or Microsoft

Windows Me

IBM PC/AT or compatible with a Pentium II 333 MHz or faster processor

(Pentium III 1 GHz or faster recommended.)

Microsoft Windows

XP

256 MB minimum (See note 2.)

Approx. 1.8 GB or more available space is required to install the complete CX-One package.

SVGA (800

× 600) or better high-resolution display with 256 colors min.

CD-ROM drive

One RS-232C port min. (See note 3.)

Internet access is required for online user registration, including a modem or other hardware connection method.

Note

(1) CX-One Operating System Precaution

The CX-One will not run on Microsoft Windows 95 or any other OS not listed above. If such an OS is being used on the client computer, the OS must be upgraded before installing the CX-One. System requirements and hard disk space may vary with the system environment.

(2) The amount of memory required varies with the Support Software used in CX-One. Refer to user documentation for individual Support Software for details.

(3) An RS-232C port is required to connect the Support Software in CX-One to a PLC. If the computer provides only a USB port, use a CS1W-CIF31

USB-to-RS-232C Conversion Cable. For connecting to the CP Series, however, an over-the-counter USB cable (type A-B) can be used.

8

System Requirements

Section 1-4

1-4-2 Hard Disk Space Requirements for Support Software in CX-One

Support Software in CX-One

CX-Programmer

CX-Integrator

CX-Position

CX-Motion

CX-Motion-NCF

CX-Motion-MCH

CX-Drive

CX-Designer

CX-Process Tool

Faceplate Auto-Builder for NS

CX-Protocol

CX-Profibus

CX-Simulator

CX-Thermo

CX-FLnet

Switch Box

CX-Server and PLC Tools

Approx. hard disk space required.

Approx. 250 MB

Approx. 100 MB

Approx. 15 MB

Approx. 40 MB

Approx. 100 MB

Approx. 100 MB

Approx. 100 MB

Approx. 500 MB

Approx. 65 MB

Approx. 50 MB

Approx. 20 MB

Approx. 10 MB

Approx. 40 MB

Approx. 20 MB

Approx. 1 MB

Approx. 5 MB

Approx. 300 MB

Remarks

Options can be selected or cleared to install or not install individual Support

Software.

Always installed.

Note

If the complete CX-One package is installed, approximately 1.8 GB of hard disk space will be required (including workspace required for installation).

Check available space on your hard disk before installing software.

9

System Requirements

Section 1-4

10

SECTION 2

Installation and Uninstallation

This section describes how to install and uninstall the software provided in the CX-One.

2-1 Installing the CX-One . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1-1 Confirmations before Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1-2 Installing the CX-One. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2 CX-One Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2-1 Modifying the Installed Support Software in the CX-One . . . . . . . .

2-2-2 Re-installing the Support Software in the CX-One . . . . . . . . . . . . .

2-2-3 Removing all the Support Software in the CX-One . . . . . . . . . . . . .

2-2-4 Uninstalling the CX-Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

21

24

26

28

12

12

12

11

Installing the CX-One

Section 2-1

2-1 Installing the CX-One

2-1-1 Confirmations before Installation

Time Requirements

Precautions for

Installation

The CX-One FA Integrated Tool Package integrates all of the Support Software for OMRON PLCs and Components. If the complete CX-One package is installed, between approximately 15 and 40 minutes will be required for installation depending on the performance of the computer.

Example: The complete CX-One package can be installed in approximately

10 minutes with an Intel Celeron 2.2-GHz processor, 512 MB or

RAM, and a 48X CD-ROM drive.

• Close all programs running on Windows before starting the installation procedure.

• The CX-One cannot be installed from a network drive, such as a CD drive or hard disk drive shared on a network. Always install the CX-One from a

CD drive on the computer onto which the software is being installed.

• Do not install onto a compressing drive. Recovery will not be possible if file corruption occurs.

• Do not stop the setup process in the middle. Copied files may remain in the installation directory.

• Do not turn OFF or reset the computer in the middle of the installation process. Computer data may become corrupted.

• The CX-One cannot be installed on Windows 95.

• For Windows 98, always use Windows 98 Second Edition.

• For Windows 2000, Service Pack 3 or later must be installed. The service pack can be confirmed by selecting Start - Settings - Control Panel -

System. The service pack will be displayed under System on the General

Tab Page of the System Properties Dialog Box. If a service pack is not displayed, no service pack has been installed. Refer to Microsoft's website for service pack installation methods.

• On Windows NT 4.0, 2000, or XP, the administrator or a user with administrator rights must perform the installation. Other users will not have sufficient write permissions and access errors will occur.

• It may be necessary to restart Windows after finishing the installation. If required, restart Windows according to the messages displayed by the

Installer.

Note

Internet Explorer version 5.0 or higher must be installed in advance to use the

CX-Server Installer. Install Internet Explorer version 5.0 in advance if it is not already installed.

2-1-2 Installing the CX-One

The following procedure is for installing the CX-One when none of the Support Software in the CX-One has been previously installed.

Note

If the complete CX-One package is installed, approximately 1.8 GB of hard disk space will be required (including workspace required for installation).

Check available space on your hard disk before installing software.

1,2,3...

1.

Insert disk 1 of the CX-One installation disks (CD-ROM) into the CD-ROM drive.

12

Installing the CX-One

Section 2-1

2.

The setup program will start automatically and the Choose Setup Language Dialog Box will be displayed.

The language of the operating system running on the computer will be selected automatically.

If the above dialog box is not displayed, double-click the CD-ROM driver from the Explorer to display it.

Select the language to be installed and then click the OK Button.

Note

Only the CX-Programmer supports languages other than English and Japanese (including Italian, Spanish, German, French, and

Chinese). If any language other than English or Japanese is selected, the CX-Programmer will be installed in the selected language and all other software will be installed in English (United States).

When the OK Button is clicked, a splash window for the CX-One will be displayed, followed by the Setup Wizard.

3.

If the CX-Server is already installed on the computer, the following dialog box will be displayed as a prompt to delete the older version of the CX-

Server.

Click the OK Button and uninstall the CX-Server. If the Cancel Button is clicked, CX-One installation will be exited.

If an earlier version of any of the Support Software is already installed in the computer, one of the following dialog boxes will be displayed.

13

Installing the CX-One

Section 2-1

Dialog Box When an Earlier Version of the CX-Programmer Is Installed

Click the OK Button and uninstall the earlier version of the CX-Programmer. If the Cancel Button is clicked, CX-One installation will continue without uninstalling the earlier version of the CX-Programmer. This would result in there being two versions of the CX-Programmer installed at the same time, so we recommend always clicking the OK Button.

Dialog Box When an Earlier Version of Other Support Software Is

Installed

Click the OK Button and uninstall the earlier version of the Support Software. If the Cancel Button is clicked, CX-One installation will be canceled.

4.

The CX-One Setup Wizard will be started. Click the Next Button.

14

Installing the CX-One

5.

The License Agreement Dialog Box will be displayed.

Section 2-1

Read the license agreement completely and if you accept all of the terms, select the I accept the terms of the license agreement Option and click the

Next Button.

6.

The User Information Dialog Box will be displayed.

The default names registered in the computer will be entered for the user name and company name. Enter the license number and click the Next

Button. The license number is given on the Software License/Registration

Card provided with the product.

15

Installing the CX-One

Section 2-1

7.

The Choose Destination Location Dialog Box will be displayed.

Select the destination location and click the Next Button. By default, the

CX-One will be installed in C:\Program Files\OMRON\CX-One\.

8.

The Setup Type Dialog Box will be displayed.

16

Note

Select the Complete or Custom Option and click the Next Button.

(1) CX-One installation will require approximately the same amount of time

(approximately 15 to 40 minutes) regardless of whether Complete or

Custom is selected. As a rule, select Complete and install the entire package at the same time provided that there is sufficient disk space available.

Installing the CX-One

Section 2-1

(2) CX-Profibus will normally not be installed. Select Custom and then select

CX-Profibus to install it.

The Select Features Dialog Box will be displayed if Custom was selected.

Note

The above dialog box will not be displayed if Complete is selected.

Proceed to step 9.

Select the features to be installed and click the Next Button.

Options

@ CX-Programmer

@ CX-Integrator

@ CX-Designer

@ CX-Position

@ CX-Motion

@ CX-Motion-NCF

@ CX-Drive

@ CX-Motion-MCH

@ CX-Process

@ Face Plate Auto-Builder for NS

@ CX-Protocol

@ CX-Thermo

@ CX-Simulator

@ SwitchBox

@ CX-Profibus

@ CX-FLnet

@ CX-Server (Selected and grayed out.)

@ PLC Tools (Selected and grayed out.)

17

Installing the CX-One

Section 2-1

9.

If Complete was selected or if Custom was selected and the Smart FB Library feature was selected, the Choose Destination Location of the

OMRON FB Library Dialog Box will be displayed.

Check the destination location and click the Next Button. By default, the

Smart FB Library will be install in C:\Program Files\OMRON\CX-One\FBL\.

10. The Select Program Folder Dialog Box will be displayed.

Specify the location to add a shortcut in the program folder of the Windows

Start Menu and click the Next Button.

18

Installing the CX-One

Section 2-1

11. The Ready to Install the Program Dialog Box will be displayed.

Click the Install Button. The Installer will start the installation.

To check the installation settings, click the Back Button. To cancel installation, click the Cancel Button.

12. The following dialog box will be displayed. Replace the installation disk

(CD-ROM) as instructed by the message and click the OK Button.

Alternatively:

19

Installing the CX-One

Section 2-1

13. The following dialog box will be displayed when the Installer completes the installation.

20

Click the Finish Button. The Readme file will be displayed.

The following dialog box will be displayed if restarting the computer is required.

Select to restart the computer immediately (default).

Select to restart the computer manually at a later time.

Select the desired option and click the Finish Button. If the Yes, I want to

restart my computer now Option is selected, the computer will be restarted and then the Readme file will be displayed.

Note (a) It may be necessary to restart Windows after finishing the installation. If required, restart Windows according to the messages displayed by the Installer.

(b) Always read the Readme.txt file before using the CX-One.

CX-One Maintenance

Section 2-2

14. The Online Registration Dialog Box will be displayed when the Readme file is closed.

Note

A wizard will be started and will connect to the OMRON CX-One website if the Register Button is clicked. (See notes a and b.)

Note (a) If the Exit Button is clicked to cancel registration, the Online Registration Dialog Box will be displayed every time CX-One Support

Software is started.

(b) Online installation will not be possible if the computer is not connected to the Internet. Enter the required information on the registration card and mail it in.

This completes installation of the CX-One.

(1) Even if the previous versions for Support Software in the CX-One are uninstalled, the folders for the previous versions will remain in C:\Program

Files\OMRON. By default, the project files and other files that were created by the Support Software (e.g., .cxp project files for CX-Programmer) will be in this directory. If this data is to be used by the CX-One, we recommended moving the files to suitable folders after installing CX-One.

(2) Any OMRON Support Software or Communications Middleware that is not included in CX-One will remain installed on the hard disk even after the CX-One is installed. This will not create any particular problems.

Examples:

• DeviceNet Configurator (Support Software)

• FinsGateway (Communications Middleware)

2-2 CX-One Maintenance

The following maintenance can be performed once the CX-One has been installed.

1,2,3...

1.

Modifying the installed Support Software in the CX-One

2.

Re-installing the Support Software in the CX-One that was previously installed

3.

Removing all the Support Software in the CX-One

2-2-1 Modifying the Installed Support Software in the CX-One

The CX-One Support Software that is installed can be modified using the following procedure.

Note

Whenever installing from an individual Support Software CD-ROM any Support Software that has previously been installed from the CX-One Package, always uninstall the previous Support Software first. Use the following procedure and clear the selection for only the individual Support Software to be reinstalled. When the installation procedure has been completed, then install the Support Software from the individual Support Software CD-ROM. The

21

CX-One Maintenance

1,2,3...

Section 2-2

Support Software will not operate properly if it is installed without first uninstalling it.

If the version of the CX-Server on the individual Support Software CD-ROM is lower than the version of the CX-Server bundled with the CX-One, install only the CX-Position and NOT the CX-Server. (A message will be displayed if the version is lower.) If a version of CX-Server that is lower than the version with the CX-One is installed, the CX-One will not operate properly.

1.

Insert disk 1 of the CX-One installation disks (CD-ROM) into the CD-ROM drive.

2.

The Choose Setup Language Dialog Box will be displayed and the language of the operating system running on the computer will be selected automatically.

(If the following dialog box is not displayed, double-click the CD-ROM driver from the Explorer to display it.)

Select the language to be installed and then click the OK Button.

3.

A splash window for the CX-One will be displayed, and the installation modification process will start.

4.

The CX-One Maintenance Wizard will be displayed.

Select the Modify Option and click the Next Button.

22

CX-One Maintenance

Section 2-2

5.

The Select Features Dialog Box will be displayed.

The features that are selected will change depending on the CX-One Support Software already installed in the computer. The CX-One installation will be modified according to the features selected here.

Select the features that are to be added or those that are not to be deleted.

Clear the selections for features that are to be deleted.

Note

• Select the features to be added.

• Be sure that all features that are not to be deleted are selected.

• Clear the selections for features to be removed.

Any Support Software feature that is not selected here will be deleted from the compute. Check the selections carefully.

Click the Next Button.

The CX-One installation will be modified according to the feature selections. Continue with the installation procedure according to the messages displayed by the Installation Wizard.

6.

If either of the following dialog boxes is displayed, replace the installation disk (CD-ROM) as instructed by the message and click the OK Button.

Alternatively:

23

CX-One Maintenance

Section 2-2

7.

The following dialog box will be displayed when the Installer completes modifying the installation. Click the Finish Button.

2-2-2 Re-installing the Support Software in the CX-One

The previously installed Support Software can be re-installed using the following procedure. This procedure should be used to restore a previous installation, e.g., if previously installed CX-One Support Software has been deleted by accident.

1,2,3...

1.

Insert disk 1 of the CX-One installation disks (CD-ROM) into the CD-ROM drive.

2.

The Choose Setup Language Dialog Box will be displayed and the language of the operating system running on the computer will be selected automatically.

(If the following dialog box is not displayed, double-click the CD-ROM driver from the Explorer to display it.)

Select the language to be installed and then click the OK Button.

24

CX-One Maintenance

Section 2-2

3.

A splash window for the CX-One will be displayed, and the re-installation process will start. The CX-One Installation Wizard will be displayed.

Select the Repair Option and click the Next Button.

The previously installed CX-One Support Software will be re-installed.

Continue with the installation procedure according to the messages displayed by the Installation Wizard.

4.

The following dialog box will be displayed when the Installer completes reinstalling the software. Click the Finish Button.

25

CX-One Maintenance

Section 2-2

2-2-3 Removing all the Support Software in the CX-One

Use the following procedure to delete all of the Support Software in the CX-

One from the computer.

Note

The CX-Server will not be deleted from the computer even if all CX-One Support Software is deleted. The CX-Server must be uninstalled separately to delete it.

1,2,3...

1.

Select Start - Settings - Control Panel - Add/Remove Programs. The

Add/Remove Programs Dialog box will be displayed.

2.

Select CX-One from the dialog box.

3.

Click the Change/Remove Button.

26

CX-One Maintenance

Section 2-2

4.

The CX-One Installation Wizard will be displayed. Select the Remove Option and click the Next Button.

5.

The following dialog box will be displayed to confirm that all CX-One software is to be removed. Click the Yes Button to start the Uninstaller that will delete the CX-One and then follow the messages in the dialog boxes to delete the CX-One.

6.

When the uninstallation has been completed, the following dialog box will be displayed. Click the Finish Button.

27

CX-One Maintenance

Section 2-2

2-2-4 Uninstalling the CX-Server

Always uninstall the CX-Server Diver Management Tools before uninstalling the CX-Server.

Note

1,2,3...

(1) Do not uninstall the CX-Server if there are other programs on the computer that use it as the communications driver, e.g., the CX-Programmer.

If the CX-Server is uninstalled, it will no longer be possible to use these other programs.

(2) Do not uninstall the CX-Server while other programs that use it as the communications driver are running on the computer, e.g., the CX-Programmer. The CX-Server may not uninstall properly if other programs are using it.

(3) When uninstalling all of the CX-Server software, always uninstall the CX-

Server Driver Management Tool before uninstalling the CX-Server. If the

CX-Server is uninstalled first, it may no longer be possible to uninstall the

CX-Server Driver Management Tool properly.

1.

Select Start - Settings - Control Panel - Add/Remove Programs. The

Add/Remove Programs Dialog Box will be displayed.

28

Select CX-Server Driver Management Tool from the dialog box and click the Change/Remove Button.

2.

A file deletion confirmation dialog box will be displayed. Click the Yes Button.

The CX-Server Driver Management Tool will be uninstalled.

CX-One Maintenance

Section 2-2

3.

An uninstall confirmation dialog box will be displayed. Click the Yes Button.

4.

The CX-Server will be uninstalled.

When the uninstallation has been completed, the following dialog box will be displayed. Click the Finish Button. The Add/Remove Programs Dialog

Box will be displayed again.

5.

In the same way, select CX-Server from the Add/Remove Programs Dialog Box, click the Change/Remove Button, and uninstall the CX-Server by repeating steps 2 though 4.

6.

Restart the computer when all programs have been uninstalled.

29

CX-One Maintenance

Section 2-2

30

Revision History

A manual revision code appears as a suffix to the catalog number on the front cover of the manual.

Cat. No. W444-E1-02

Revision code

The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version.

Revision code

01

02

Date

February 2005

November 2005

Revised content

Original production

Revisions for upgrading from CX-One Ver. 1.0 to Ver. 1.1.

31

32

Revision History

OMRON Corporation

Control Devices Division H.Q.

Shiokoji Horikawa, Shimogyo-ku,

Kyoto, 600-8530 Japan

Tel: (81)75-344-7109/Fax: (81)75-344-7149

Regional Headquarters

OMRON EUROPE B.V.

Wegalaan 67-69, NL-2132 JD Hoofddorp

The Netherlands

Tel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ELECTRONICS LLC

1 East Commerce Drive, Schaumburg, IL 60173

U.S.A.

Tel: (1)847-843-7900/Fax: (1)847-843-8568

OMRON ASIA PACIFIC PTE. LTD.

83 Clemenceau Avenue,

#11-01, UE Square,

Singapore 239920

Tel: (65)6835-3011/Fax: (65)6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road,

PuDong New Area, Shanghai, 200120 China

Tel: (86)21-5037-2222/Fax: (86)21-5037-2200

Authorized Distributor:

Cat. No. W444-E1-02 Note: Specifications subject to change without notice

This manual is printed on 100% recycled paper.

Printed in Japan

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals