User manual | Daikin VRV II Series, VRV K Series Air Conditioner Catalog

Show HTML Add to My manuals
22 Pages

advertisement

Daikin VRV II Series & VRV K Series Catalog | Manualzz
Warning
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
PCG0558
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an
outdoor unit with anti-corrosion treatment.
The air conditioners manufactured
by Daikin Industries have
received ISO 9001 certification for
quality assurance.
Certificate Number. JMI-0107
JQA-0495
JQA-1452
All Daikin Industries locations
and subsidiaries in Japan have
received environmental
management system standard
ISO 14001 certification.
Daikin Industries, Ltd.
Domestic Group
Certificate Number. EC99J2044
Dealer
About ISO 14001
ISO 14001 is the standard defined by the
International Organization for Standardization (ISO)
relating to environmental management systems.
Our group has been acknowledged by an
internationally accredited compliance organisation
as having an appropriate programme of
environmental protection procedures and activities
to meet the requirements of ISO 14001.
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global/
c All rights reserved
Printed in Japan 10/05/003 Y.K.
The specifications, designs, and information in this brochure are subject to change without notice.
AIR CONDITIONERS
LINE UP
Split
SkyAir
VRV
Packaged Air Conditioners
DAIKIN AS A GLOBAL CORPORATE CITIZEN
Examples of installation
Ministry of Agriculture &
Fisheries Laboratory
Oman
April 2002
7 VRV Plus
Contents
3
Al Nokhba Tower
(Elite Residential Suites)
Kuwait
June 2003
11 VRV Plus
S P L I T T y pe A i r C o n di t i o n e r s
7
Sanabel Tower Hotel
Saudi Arabia
January 2001
75 VRV Plus
Air Cooled Split Type Air Conditioners
Osaka Head Office
Awqaf Tower
Qatar
June 2004
8 VRV Plus
Tokyo Head Office
Osaka Head Office
Production Site
Tokyo Head Office
Overseas Affiliate
Production Site
Sales Agent
Overseas Affiliate
21
The Intelligent Air Conditioning System
Sales Agent
28.....HRV
29.....Control Systems
ASIA/OCEANIA
CHINA
EUROPE
33
Reliability derived from 80 years of achievement
Daikin Europe N.V.
Daikin Industries
Czech Republic
Daikin Airconditioning
UK
Shanghai Daikin Airconditioning
X'ian Daikin Qing'an
Compressor
Huizhou Daikin Suns
Airconditioning
Since it's foundation in 1924, Daikin Industries, Ltd. has constantly been
developing to become a global leader in an array of fields, such as air
conditioning systems, refrigerants, fluorochemicals, electronics and hydraulic
machineries. In particular, Daikin holds the largest market share of both
residential- and commercial-use air conditioning systems in Japan. It is
the world's sole manufacturer that combines research, development and
manufacturing of air conditioning systems, refrigerants and compressors.
Daikin Industries (Thailand)
Daikin Airconditioning
Singapore
PACKAGED
AIR CONDITIONERS
42.....Water Chillers
Daikin Australia
JAPAN
U.S.A.
Daikin Airconditioning
France
Daikin Airconditioning
Spain
1
Daikin Airconditioning
Germany
Daikin Airconditioning
Italy
Daikin Fluoro Coatings
(Shanghai)
Daikin (China) Investment
Kanaoka Factory,
Sakai Plant
Shiga Plant
Yodogawa Plant
Rinkai Factory,
Sakai Plant
Kashima Factory
Daikin (China) Investment Daikin (China) Investment
Shanghai Branch
Guangzhou Branch
Daikin America
Daikin Industries Head Office
2
SPLIT Type Air Conditioners
Note: Availability of the products shown in this catalog varies by country.
Line up
Type
Split type air conditioners
Wall-mounted type...............................5
The Split System is the ideal air conditioning solution for one room or
an area of your home. Daikin air conditioners lead the industry with
their energy savings. Each indoor unit features silent operation
function, bringing comfort in your living room or bedroom.
Daikin now has a new D series. The simple and stylish design softly
harmonizes with your living space.
RT
Btu
kcal
kW
Model Name
Wallmounted
type
FT-D
C/O 60 Hz
FT-GA
C/O 60 Hz
FT-GA
C/O 50 Hz
Capacity class
1.42
17,100
4,300
5.0
1.72
20,500
5,160
6.0
FTY-GA H/P 60 Hz
Function list
Function
Wall-mounted type
FT60D
FT50/60GA FTY50/60GA
Power-airflow dual flaps
Power airflow flap
Comfortable
airflow
W I DE
ANGLE
Wide-angle louvers
Vertical auto-swing
Horizontal auto-swing
AUT O
Comfort
control
operation
Auto fan speed
Program dry function
Automatic operation
Lifestyle
convenience
N EW
New powerful operation
Indoor unit On/Off switch
Air-purifying filter
Air-purifying filter with photocatalytic deodorizing function
Wipe-Clean flat panel
Healthy &
clean
Mold-proof air filter
Washable grille
C L E AN Filter cleaning indicator
24
24-hour On/Off timer
Timer
Night set mode
Auto-restart after power failure
Worry free
SELF
Self-diagnosis digital display
Anticorrosion treatment of outdoor heat exchanger fin
3
4
SPLIT Type Air Conditioners
Wall-mounted type
FT-D Series
FT(Y)-GA Series
5.0·6.0 kW
Affordable Comfort You deserve
5.0·6.0 kW
Comfortable
Brand-New Sleek Flat Panel Design
Unique features such as our Vertical auto-swing and Horizontal auto-swing
will keep your home wrapped in a cloud of air-conditioned comfort.
Compact and Stylish Design
Compact and quiet
The rounded contours of the compact, lightweight indoor unit allow it to
harmonize smoothly with your interior decor, and an improved fan design
makes operating noise hardly noticeable.
Energy-saving
Using your air conditioner for extended periods of time is now a completely
affordable luxury thanks to Daikin’s advanced energy-saving technology.
The compact and stylish design of Daikin units
harmonizes with any interior decor. The innovative
flat panel of the new D series enhances this effect
and also ensures optimum operation.
Heating
Cooling
The flap descends to blow
warm air directly down
to the floor to quickly warm
the whole room.
The flap flattens out so that
cool air slides off to reach
the farthest corners of the
room.
Outdoor Unit
Indoor Unit
Wireless
remote controller
Wipe-Clean
Flat Panel
FT(Y)50/60GA
High Energy Savings
Daikin air conditioners’ advanced technology allows them
to achieve significant energy savings with a COP of 2.55
even during periods of extended use.
Air-Purifying Filter with Photocatalytic Deodorizing Function is
able to remove both bacteria and viruses, in addition to
eliminating mold and odors. It can be used for approximately
3 years with appropriate maintenance.
Outdoor Unit
Indoor Unit
Indoor unit
FT50GAVEA
Outdoor unit
R50GV1K
Cooling capacity
*1 (1)/(2)
Power comsumption (220-240 V) *1 (1)/(2)
COP (220-240 V) *1 (2)
Operation range(Outdoor unit)
FT60D
FT60GAVEA
R60GV1K
R60D
Cooling Only (60 Hz)
Indoor unit
FT60DVMK
Outdoor unit
R60DVLK
Power comsumption *1 (1)/(2)
COP *1 (1)
Operation range (Outdoor unit)
•
°CDB
5
Cooling capacity
*1 (2)/(3)
1 phase, 220 V, 60 Hz
1.96/1.59
23,500/19,100
5,900/4,800
6.9/5.6
2.71/3.10
2.55
19.4 to 54
Notes : *1:Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
1.83/1.82
22,000/21,800
5,540/5,500
6.44/6.40
2.42/2.41-2.51/2.50
2.66-2.56
°CDB
19.4 to 54
Cooling Only (60 Hz)
Model
*1 (1)/(2)
1.52/1.51
18,200/18,100
4,590/4,560
5.34/5.30
2.01/2.00-2.19/2.18
2.65-2.43
RT
Btu/h
kcal/h
kW
kW
Heat Pump (60 Hz)
Indoor unit
FT50GAVAL
FT60GAVAL
FTY50GAVAL
FTY60GAVAL
Outdoor unit
R50GVAL
R60GVAL
RY50GVAL
RY60GVAL
Power Supply
RT
Btu/h
kcal/h
kW
kW
RY60G
1 phase, 220-240 V, 50 Hz
Power Supply
Cooling capacity
RY50G
Cooling Only (50 Hz)
Model
Power Supply
R60G
Wireless
remote controller
FT50/60GA
Model
R50G
Healthy and Clean
Heating capacity
*2(1)/(2)
Conversion rates
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
1.59/1.28
19,100/15,400
4,800/3,900
5.6/4.5
—
—
—
—
2.18/2.50
—
2.57
—
1 phase, 220 V, 60 Hz
1.93/1.59
23,200/19,100
5,850/4,800
6.8/5.6
—
—
—
—
2.68/3.06
—
2.54
—
1.65/1.42
19,800/17,100
4,990/4,300
5.8/5.0
1.79/1.71
21,500/20,500
5,420/5,200
6.3/6.0
2.00/2.30
1.87/1.85
2.90
3.37
Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling *1 (2)
COP
Heating *2 (2)
19.4 to 54
19.4 to 54
Operation range Cooling
°CDB
(Outdoor unit)
—
-10 to 15
Heating
°CWB
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2:Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB. Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Power comsumption
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
1 phase, 220 V, 60 Hz
1.85/1.59
22,200/19,100
5,590/4,800
6.5/5.6
2.04/2.02
24,500/24,200
6,180/6,100
7.19/7.10
2.61/2.97
2.44/2.46
2.49
2.95
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
6
Air Cooled Split Type Air Conditioners
Note: Availability of the products shown in this catalog varies by country.
Type
Capacity
Line Up
Model Name
RT
1.6
1.9
2.3
3.2
4.1
4.5
6.8
8.3
13.6
16.6
Btu
19100
23200
27600
38900
48800
53900
81900
99600
163400
199300
kW
5.6
6.8
8.1
11.4
14.3
15.8
24.0
29.2
47.9
58.4
2
2.5
3
4
5
6
8
10
15
20
HP
FHC
Ceiling
mounted
cassette type
Indoor units.....................................10
60 Hz
FHYC
H/P
FH
C/O
FHY
H/P
60 Hz
FHK
C/O
50 Hz
Ceiling
mounted
built-in type
FHB
C/O
50 Hz
FHYB
H/P
60 Hz
Wall mounted
type
FA
C/O
FAY
H/P
FV
C/O
FVY
H/P
Ceiling
suspended type
Ceiling mounted
cassette corner
type
Floor standing
type
Packaged air conditioners
Stores often feature the latest in designed decor. This refined beauty attracts
people.
Meanwhile, offices have a functional beauty. This encourages those within to
work hard and apply intelligence and passion to their tasks.
In either situation, a certain elegance should fill the space because thinking
minds require high quality air conditioning. SkyAir by Daikin ensures a
comfortable indoor environment. All over the world, stores, offices, and homes
prefer the low operating noise, attractive design, complete comfort control,
and other benefits brought by SkyAir.
C/O
FH(Y)C
Specifications..................................11
Simultaneous operation system......16
50 Hz
FDBG
Duct
connection
low static
pressure
type
FDB
FDYB
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
60 Hz
50 Hz
60 Hz
60 Hz
50 Hz
C/O
60 Hz
H/P
60 Hz
50 Hz
FDMG
Duct
connection
middle static
pressure
type
50 Hz
C/O
60 Hz
FD(Y)M
50 Hz
H/P
Duct
connection
high static
pressure
type
FD
C/O
FDY
H/P
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
Operation system
Applicable Models
Capacity
Simultaneous operation system
RT
4.5
6.3
7.6
Btu
53900
75700
90800
kW
15.8
22.2
26.6
6
8
10
HP
50 Hz
C/O
Indoor unit
Indoor unit
60 Hz
Twin
50 Hz
Outdoor
unit
H/P
50 Hz
Indoor unit
Triple
60 Hz
*1
C/O
60 Hz
Indoor unit
Indoor unit
Outdoor
unit
*2
50 Hz
H/P
60 Hz
*2
50 Hz
Indoor unit
Double
Twin
C/O
60 Hz
Indoor unit
Indoor unit
Indoor unit
Outdoor
unit
50 Hz
H/P
*1
60 Hz
Notes: •Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
7
•The values given for 2 HP to 6 HP are for the FHY(C) model and 8 HP to 20 HP are for the FD model. The values given for simultaneous operation system are for the FHYC model.
•*1:FDYB and FDYM model operate for 20·25 (kW) class.
•*2:FDYB and FDYM model operate for 20 (kW) class.
8
Air Cooled Split Type Air Conditioners
Indoor units
Ceiling Mounted Built-in Type
Ceiling Mounted Cassette Type
Quiet,decor-blending form and easy
installation in new or old buildings.
Multiple unit installations maintain a
physical uniformity that is
aesthetically pleasing and make it
easier to plan ceiling lighting
systems and to design interiors.
With the use of simple ducts,
discharge outlets can be located
in a multitude of ways. Top priority
given to interior decor, built-in
type units realize ideal air current
distribution.
FH(Y)B
FH(Y)C
Ceiling Suspended Type
Wall Mounted Type
Wall mounted type units feature
the lowest sound levels in the
industry and greatly upgraded
comfort, thanks to the high fan
speed mode.
On-ceiling installation leaves floor
space unhindered. Extremely
quiet operation enhances the
store's customer service.
FH(Y)
FA(Y)
Ceiling Mounted Cassette Corner Type
Uni-directional discharge outlet is
perfect for corner installation.
A thin, 21.5 cm main body
enables installation even in a
small ceiling overhead space.
Floor Standing Type
Floor standing type units are easy to
install and maintain; their slimness is
suitable for installation in high-ceiling
stores and offices.
FHK
FV(Y)
Packaged Air Conditioners Duct Connection Series
Low static pressure
Middle static pressure
High static pressure
FDMG
FDB(G)
FDYB
FD(Y)M
FD(Y)
For details, please refer to P33-P40.
Outdoor Unit
R emote C ontroller
LCD Wireless
LCD Wired
Remote Controller Remote Controller
9
10
Air Cooled Split Type Air Conditioners—Specifications
(For specifications of duct connection series, please refer to P35-P40.)
C ooling Only (50 Hz)
Ceiling mounted cassette type
Indoor unit
Model
Outdoor unit
Wall mounted type
50
60
71
100
125
FHC50KVE
FHC60KVE
FHC71KVE
FHC100KVE
FHC125KVE
R71FUV1
R100FUV1
R71FUY1
R100FUY1
R60GV1K
R50GV1
Power supply
R125FUY1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V,50 Hz/Y1: 3 phase, 380-415 V,50 Hz
kW
RT
1.5/1.5
1.8/1.8
2.2/2.2
3.0/3.0
Cooling capacity
Btu/h
18,200/18,100
22,000/21,800
26,600/26,300
36,200/35,800
44,400/43,700
*1 (1)/(2)
kcal/h
4,590/4,560
5,540/5,500
6,700/6,600
9,100/9,000
11,200/11,000
Power comsumption *1 (1)/(2)
7.80/7.7
10.6/10.5
2.55/2.53
10.6/10.5
13.0/12.8
3.69/3.65
4.39/4.35
Power comsumption *1 (1)/(2)
2.87/2.88
2.96/2.94
COP *1 (1)/(2)
3.6/3.56
3.06/3.04
2.94/2.95
°CDB
Operation range (Outdoor temp.)
21 to 52
Floor standing type
50
60
71
100
125
FH50BVE
FH60BVE
FH71BVE
FH100BVE
FH125BVE
R71FUV1
R100FUV1
R71FUY1
R100FUY1
R50GV1
R60GV1K
R125FUY1
RT
1.5/1.4
1.9/1.8
2.2/2.2
3.0/3.0
Btu/h
17,700/17,400
22,500/22,200
26,600/26,300
36,200/35,800
44,400/43,700
kcal/h
4,460/4,400
5,690/5,600
6,700/6,600
9,100/9,000
11,200/11,000
Power comsumption *1 (1)/(2)
3.7/3.6
36,200/35,800
44,400/43,700
6,700/6,600
9,100/9,000
11,200/11,000
kW
7.8/7.7
10.6/10.5
13.0/12.8
2.58/2.56
3.79/3.75
4.67/4.63
Power comsumption *1 (1)/(2)
3.02/3.01
2.80/2.80
2.78/2.76
COP *1
7.80/7.7
kW
10.6/10.5
2.67/2.65
13.0/12.8
3.76/3.74
2.92/2.91
(1)/(2)
Operation range (Outdoor temp.)
4.49/4.45
2.82/2.81
°CDB
2.9/2.88
21 to 52
•
Notes : *1:Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
45
60
Indoor unit
FHK45FV1
FHK60FV1
Outdoor unit
R50GV1
R60GV1K
Power supply
C ooling Only (60 Hz)
1 phase, 220-240 V, 50 Hz
RT
1.5/1.4
1.9/1.8
Cooling capacity
Btu/h
17,700/17,400
22,500/22,200
*1 (1)/(2)
kcal/h
4,460/4,400
5,690/5,600
kW
5.19/5.1
6.6/6.5
kW
2.25/2.24
2.76/2.74
2.31/2.28
°CDB
Ceiling mounted cassette type
Model
2.39/2.37
45
60
Indoor unit
FHB45FV1
FHB60FV1
Outdoor unit
R50GV1
R60GV1K
Power supply
60
FHC60KVE
71
FHC71KVE
100
FHC100KVE
125
FHC125KVE
125
FHYC125KVE
140
FHYC140KVE
Outdoor unit
R50GVAL
R60GVAL
R71FUVAL
R100FUVAL
R125FUTAL
R125KUYALK
R140KUTALK
R140KUYALK
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
Cooling capacity
Btu/h
17,700/17,400
22,500/22,200
*1 (1)/(2)
kcal/h
4,500/4,400
5,700/5,600
kW
5.19/5.1
6.6/6.5
kW
2.33/2.32
2.78/2.76
2.23/2.20
2.37/2.36
RT
1.6/1.3
1.9/1.6
2.3/1.9
3.2/2.6
Cooling capacity
Btu/h
19,100/15,400
23,200/19,100
27,600/22,900
38,900/30,700
48,800/42,700
48,800/42,700
53,900/47,800
*1 (1)/(2)
kcal/h
4,800/3,900
5,800/4,800
7,000/5,800
9,800/7,700
12,300/10,800
12,300/10,800
13,600/12,000
Power comsumption *1 (1)/(2)
Operation range (Outdoor temp.)
1.9/1.8
4.1/3.6
4.1/3.6
kW
5.6/4.5
6.8/5.6
8.1/6.7
11.4/9.0
14.3/12.5
14.3/12.5
15.8/14.0
kW
2.21/2.5
2.73/3.14
3.34/4.2
4.54/5.80
6.08/7.00
5.50/6.80
5.70/
2.53
2.49
2.43
2.51
2.35
2.60
°CDB
19.4 to 54
2.77
21 to 54
Ceiling suspended type
50
Model
71
100
125
FH50BVE
FH60BVE
FH71BVE
FH100BVE
FH125BVE
R50GVAL
R60GVAL
R71FUVAL
R100FUVAL
R125FUTAL
Power supply
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
1.5/1.3
1.8/1.6
2.3/1.9
3.2/2.6
4.1/3.6
Cooling capacity
Btu/h
17,900/15,400
22,200/19,100
27,600/22,900
38,900/30,700
48,800/42,700
*1 (1)/(2)
kcal/h
4,500/3,900
5,600/4,800
7,000/5,800
9,800/7,700
12,300/10,800
kW
5.25/4.5
6.5/5.6
8.1/6.7
11.4/9.0
14.3/12.5
kW
2.3/2.5
2.84/3.2
3.44/4.2
4.67/5.80
6.25/7.00
2.28
2.29
2.35
2.44
2.29
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
60
Indoor unit
Outdoor unit
Power comsumption *1 (1)/(2)
COP *1 (1)
Operation range (Outdoor temp.)
•
°CDB
19.4 to 54
21 to 54
Notes : *1:Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
11
4.5/4.0
KUTALK.....6.80, KUYALK.....7.10
19.4 to 54
Notes : *1:Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
50
FHC50KVE
COP *1 (1)
1 phase, 220-240 V, 50 Hz
1.5/1.4
Indoor unit
Power supply
19.4 to 54
Ceiling mounted built-in type
°CDB
3.0/3.0
26,600/26,300
6.6/6.5
COP *1 (1)/(2)
2.2/2.2
Btu/h
2.8/2.78
RT
R125FUY1
kcal/h
2.36/2.34
COP *1 (1)/(2)
R100FUY1
*1 (1)/(2)
5.19/5.1
Ceiling mounted cassette corner type
Power comsumption *1 (1)/(2)
R71FUY1
Cooling capacity
2.40/2.37
21 to 52
125
FV125LAVE
R100FUV1
RT
3.7/3.6
2.16/2.15
19.4 to 54
100
FV100LAVE
R71FUV1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
kW
°CDB
71
FV71LAVE
Outdoor unit
Power supply
kW
COP *1 (1)/(2)
Operation range (Outdoor temp.)
Indoor unit
Model
*1 (1)/(2)
•
kW
kW
7.8/7.7
3.00/2.98
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
Operation range (Outdoor temp.)
9,100/9,000
2.60/2.58
Outdoor unit
Power comsumption *1 (1)/(2)
36,200/35,800
6,700/6,600
6.44/6.4
Cooling capacity
Model
26,600/26,300
kcal/h
2.63/2.62
Power supply
Operation range (Outdoor temp.)
3.0/3.0
Btu/h
*1 (1)/(2)
2.45/2.44
Indoor unit
Model
R100FUY1
Cooling capacity
5.34/5.3
Ceiling suspended type
Model
R71FUY1
2.2/2.2
2.64/2.64
21 to 52
R100FUV1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
2.02/2.01
19.4 to 54
100
FA100FVEK
R71FUV1
RT
3.7/3.6
kW
°CDB
71
FA71FVEK
Outdoor unit
Power supply
kW
COP *1 (1)/(2)
Operation range (Outdoor temp.)
Indoor unit
Model
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
12
Air Cooled Split Type Air Conditioners—Specifications
(For specifications of duct connection series, please refer to P35-P40.)
Heat Pump (60 Hz)
Wall mounted type
Ceiling mounted cassette type
71
Model
100
Indoor unit
FA71FVEK
FA100FVEK
Outdoor unit
R71FUVAL
R100FUVAL
Power supply
Model
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz
2.3/1.9
3.2/2.7
Cooling capacity
Btu/h
27,600/22,900
38,900/32,400
*1 (1)/(2)
kcal/h
7,000/5,800
9,800/8,200
kW
8.1/6.7
11.4/9.5
kW
3.27/4.1
4.41/5.70
2.48
2.59
COP *1 (1)
Operation range (Outdoor temp.)
°CDB
Outdoor unit
21 to 54
71
100
125
FV71LAVE
FV100LAVE
FV125LAVE
R71FUVAL
Power supply
R100FUVAL
R125FUTAL
2.3/1.9
3.2/2.6
4.1/3.6
Cooling capacity
27,600/22,900
38,900/30,700
48,800/42,700
*1 (1)/(2)
kcal/h
7,000/5,800
Operation range (Outdoor temp.)
9,800/7,700
12,300/10,800
kW
8.1/6.7
11.4/9.0
14.3/12.5
kW
3.40/4.3
4.62/5.90
6.20/7.10
2.47
2.31
2.38
•
°CDB
125
FHYC125KVE
Outdoor unit
RY50GVAL
RY60GVAL
RY71FUVAL
RY100FUVAL
RY125FUTAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
Btu/h
1.6/1.4
1.8/1.6
2.3/1.9
3.2/2.6
4.1/3.6
4.5/4.0
19,800/17,100
22,200/19,100
27,600/22,900
38,900/30,700
48,800/42,700
53,900/47,800
4,990/4,300
5,590/4,800
7,000/5,800
9,800/7,700
12,300/10,800
13,500/12,000
RT
1.8/1.7
2.0/2.0
2.6/2.4
3.6/3.4
4.6/4.3
5.1/4.8
Heating capacity
Btu/h
21,500/20,500
24,500/24,200
30,700/29,000
43,700/40,300
55,300/51,200
61,800/58,000
*2 (1)/(2)
kcal/h
5,420/5,200
6,180/6,100
11,000/10,100
12.8/11.8
13,900/12,900
16.2/15.0
15,600/14,600
18.1/17.0
Operation range
(Outdoor temp.)
Cooling *1 (1)/(2)
Heating *2 (1)/(2)
Cooling
*1 (1)
Heating
*2 (1)
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
5.8/5.0
Heating
8.1/6.7
6.5/5.6
11.4/9.0
14.3/12.5
15.8/14.0
kW
6.3/6.0
7.19/7.1
7,700/7,300
9.0/8.5
kW
kW
2.03/2.34
2.66/3.06
3.72/4.30
4.69/5.90
5.88/6.60
5.70/7.30
1.87/1.85
7.19/7.1
9.0/8.5
12.8/11.8
16.2/15.0
18.1/17.0
2.86
3.37
2.44
2.92
2.18
2.43
2.43
2.77
2.59
2.90
°CDB
°CWB
Cooling
19.4 to 54
3.23
3.01
-5 to 54
-10 to 15
-10 to 15
-10 to 15.5
Ceiling suspended type
Model
50
FHY50BVE
RY50GVAL
Indoor unit
Outdoor unit
Power supply
60
FHY60BVE
RY60GVAL
71
FHY71BVE
RY71FUVAL
100
FHY100BVE
RY100FUVAL
125
FHY125BVE
RY125FUTAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
RT
1.6/1.4
1.8/1.6
2.3/1.9
3.2/2.6
4.1/3.6
Cooling capacity
Btu/h
19,800/17,100
22,200/19,100
27,600/22,900
38,900/30,700
48,800/42,700
*1 (1)/(2)
kcal/h
4,990/4,300
5,590/4,800
7,000/5,800
9,800/7,700
12,300/10,800
RT
1.8/1.7
2.0/2.0
2.6/2.4
3.6/3.4
4.6/4.3
Heating capacity
Btu/h
21,500/20,500
24,500/24,200
30,700/29,000
43,700/40,300
55,300/51,200
*2 (1)/(2)
kcal/h
5,420/5,200
6,180/6,100
7,700/7,300
11,000/10,100
13,900/12,900
21 to 54
Notes : *1:Nominal cooling capacities are based on the following conditions:
(1) Return air temperature:27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature:29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
140
FHYC140KVE
RY140KUTALK
RY140KUYALK
kcal/h
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
COP *1 (1)
100
FHYC100KVE
Cooling capacity
COP
Btu/h
Power comsumption *1 (1)/(2)
71
FHYC71KVE
*1 (1)/(2)
Power comsumption
Indoor unit
60
FHYC60KVE
kW
Floor standing type
Model
50
FHYC50KVE
Power supply
RT
Power comsumption *1 (1)/(2)
Indoor unit
kW
Power comsumption
COP
Operation range
(Outdoor temp.)
Cooling *1 (1)/(2)
Heating *2 (1)/(2)
Cooling *1 (1)
Heating *2 (1)
Cooling
Heating
5.8/5.0
6.5/5.6
8.1/6.7
11.4/9.0
14.3/12.5
kW
6.3/6.0
7.19/7.1
9.0/8.5
12.8/11.8
16.2/15.0
kW
kW
2.14/2.34
2.77/3.06
3.82/4.30
4.82/5.90
6.05/6.60
1.98/1.86
2.57/2.44
3.60/3.80
4.57/5.00
5.58/5.42
2.35
2.12
2.37
2.36
2.80
2.50
2.80
2.90
2.71
3.18
°CDB
°CWB
19.4 to 54
-5 to 54
-10 to 15
-10 to 15.5
Ceiling mounted built-in type
Model
71
100
125
Indoor unit
FHYB71FVAL
FHYB100FVAL
FHYB125FVAL
Outdoor unit
RY71FUVAL
RY100FUVAL
RY125FUTAL
Power supply
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
RT
2.3/1.9
3.2/2.6
4.1/3.6
Cooling capacity
Btu/h
27,600/22,900
38,900/30,700
48,800/42,700
*1 (1)/(2)
kcal/h
7,000/5,800
9,800/7,700
12,300/10,800
kW
8.1/6.7
11.4/9.0
14.3/12.5
RT
2.6/2.4
3.6/3.4
4.6/4.3
Heating capacity
Btu/h
30,700/29,000
43,700/40,300
55,300/51,200
*2 (1)/(2)
kcal/h
7,700/7,300
11,000/10,100
13,900/12,900
Power comsumption
COP
Operation range
(Outdoor temp.)
•
Cooling *1 (1)/(2)
Heating *2 (1)/(2)
kW
9.0/8.5
12.8/11.8
16.2/15.0
kW
kW
3.82/4.30
4.76/5.90
6.05/6.70
3.57/3.80
4.49/5.00
5.56/5.60
Cooling
*1 (1)
2.12
2.39
2.36
Heating
*2 (1)
2.52
2.85
2.91
Cooling
°CDB
-5 to 54
Heating
°CWB
-10 to 15.5
Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•
13
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
14
Air Cooled Split Type Air Conditioners—Specifications
Simultaneous Operation System—Twin & Triple & Double Twin Multi Application Operation
(For specifications of duct connection series, please refer to P35-P40.)
Simultaneously operates 2 to 4 indoor units using
a single outdoor unit.
Wall mounted type
71
Model
100
Indoor unit
FAY71FVE
FAY100FVE
Outdoor unit
RY71FUVAL
RY100FUVAL
Power supply
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz
RT
2.3/1.9
3.2/2.6
Cooling capacity
Btu/h
27,600/22,900
38,900/30,700
*1 (1)/(2)
kcal/h
7,000/5,800
9,800/7,700
kW
8.1/6.7
11.4/9.0
RT
2.6/2.4
3.6/3.4
Heating capacity
Btu/h
30,700/29,000
43,700/40,300
*2 (1)/(2)
kcal/h
7,700/7,300
11,000/10,100
kW
9.0/8.5
12.8/11.8
kW
kW
3.67/4.20
4.61/5.80
3.44/3.70
4.36/4.90
2.21
2.47
Power comsumption
In large interior spaces a single indoor unit may not be able
to provide uniform comfort. Installation of 2 to 4 units,
distributed to consider sun light and human gathering
patterns, can provide an effective solution.
Cooling *1 (1)/(2)
Heating *2 (1)/(2)
COP
Cooling
Heating
Operation range
(Outdoor temp.)
Cooling
Heating
*1 (1)
2.62
*2 (1)
Installing multiple units is
economical and ensures comfort
Lower cost of installation than for individual pair type
Less space needed for outdoor units
Enhanced comfort from distributed indoor units
2.94
-5 to 54
°CDB
°CWB
-10 to 15.5
In a single-floor restaurant, for example, positioning 4 units
at strategic locations achieves comfortable air flow that
reaches every inch of the room.
Floor standing type
Note: This type of system does not allow individual control or independent operation of
indoor units. It is not the best choice for large rooms with partitions.
71
Model
100
125
Indoor unit
FVY71LAVE
FVY100LAVE
FVY125LAVE
Outdoor unit
RY71FUVAL
RY100FUVAL
RY125FUTAL
Power supply
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
Cooling capacity
*1 (1)/(2)
2.3/1.9
3.2/2.6
4.1/3.6
Btu/h
27,600/22,900
38,900/30,700
48,800/42,700
Refrigerant piping uses terminal branching to facilitate installation
12,300/10,800
•Branch piping kit is optionally available.
kcal/h
7,000/5,800
9,800/7,700
kW
8.1/6.7
11.4/9.0
14.3/12.5
RT
2.6/2.4
3.6/3.4
4.6/4.3
Heating capacity
Btu/h
30,700/29,000
43,700/40,300
55,300/51,200
*2 (1)/(2)
kcal/h
7,700/7,300
11,000/10,100
13,900/12,900
kW
9.0/8.5
12.8/11.8
16.2/15.0
kW
kW
3.78/4.40
4.77/6.00
6.00/6.70
3.55/3.90
4.52/5.15
5.53/5.60
2.14
2.39
2.38
2.83
2.93
Power comsumption
Cooling *1 (1)/(2)
Heating *2 (1)/(2)
COP
Cooling
Heating
Operation range
(Outdoor temp.)
Cooling
Heating
•
*1 (1)
2.54
*2 (1)
°CDB
°CWB
(Indoor units are limited to same capacity and type combination.)
Precautions when selecting optional remote controller
•An optional remote controller is required for one of the combination indoor units.
•Optional remote controllers are a single item, and cannot operate the air conditioning individually. Indoor units should not therefore be installed in separate rooms.
•If operating with optional wireless remote controllers, set one as the main unit and install a light receptor.
Twin Multi Application
-5 to 54
-10 to 15.5
Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•
Indoor units include the super cassette type, duct connection low and middle static pressure type and ceiling suspended type.
RT
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
Branch piping kit
Branch piping kit
Triple Multi Application
Branch piping kit
Double Twin Multi Application
Branch piping kit
Branch piping kit
*Typical combination
15
16
Simultaneous Operation System—Twin & Triple & Double Twin Multi Application Operation
(For specifications of duct connection series, please refer to P35-P40.)
C ooling Only (50 Hz)
Ceiling mounted cassette type
Model
Indoor unit
Ceiling suspended type
200
250
200
250
FHYC100KVEX 2
FHYC125KVEX 2
FHY100BVEX 2
FHY125BVEX 2
FHYC71KVEX 3
Outdoor unit
Power supply
RT
FHYC50KVEX 4
FHYC60KVEX 4
R200KUY1
R250KUY1
Model
Indoor unit
FHY71BVEX 3
Outdoor unit
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
7.7/7.6
Power supply
RT
FHY50BVEX 4
FHY60BVEX 4
RY200KUY1
RY250KUY1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
7.7/7.6
Cooling capacity
Btu/h
76,800/75,700
92,500/90,800
Cooling capacity
Btu/h
76,800/75,700
92,500/90,800
*1 (1)/(2)
kcal/h
19,400/19,100
23,300/22,900
*1 (1)/(2)
kcal/h
19,400/19,100
23,300/22,900
kW
22.5/22.2
27.1/26.6
kW
22.5/22.2
27.1/26.6
7.7/7.6
9.7/9.7
RT
6.4
8.1
2.92/2.92
2.79/2.74
Heating capacity
Btu/h
77,500
96,900
*2 (1)
kcal/h
19,500
24,400
Power comsumption *1 (1)/(2)
COP *1
kW
(1)/(2)
Operation range (Outdoor temp.)
°CDB
-5 to 52
Ceiling suspended type
Power comsumption
Indoor unit
200
250
FHY100BVEX 2
FHY125BVEX 2
FHY71BVEX 3
Model
Outdoor unit
Power supply
RT
FHY50BVEX 4
FHY60BVEX 4
R200KUY1
R250KUY1
Btu/h
76,800/75,700
92,500/90,800
*1 (1)/(2)
kcal/h
19,400/19,100
23,300/22,900
kW
22.5/22.2
27.1/26.6
Power comsumption *1 (1)/(2)
kW
7.7/7.6
Operation range (Outdoor temp.)
°CDB
Cooling
*1 (1)/(2)
Heating
*2 (1)
22.7
kW
kW
7.7/7.6
•
28.4
9.7/9.7
6.5
9.2
2.92/2.92
2.79/2.74
3.49
3.09
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
9.7/9.7
2.92/2.92
(1)/(2)
•
Heating *2 (1)
kW
Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
7.7/7.6
Cooling capacity
COP *1
COP
Cooling *1 (1)/(2)
2.79/2.74
-5 to 52
Heat Pump (50 Hz)
Ceiling mounted cassette type
Model
Indoor unit
200
250
FHYC100KVEX 2
FHYC125KVEX 2
FHYC71KVEX 3
Outdoor unit
Power supply
RT
FHYC50KVEX 4
FHYC60KVEX 4
RY200KUY1
RY250KUY1
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
7.7/7.6
Cooling capacity
Btu/h
76,800/75,700
92,500/90,800
*1 (1)/(2)
kcal/h
19,400/19,100
23,300/22,900
kW
22.5/22.2
27.1/26.6
RT
6.4
8.1
Btu/h
77,500
96,900
Heating capacity
*2 (1)
kcal/h
Power comsumption
Cooling *1 (1)/(2)
Heating *2 (1)
Cooling *1 (1)/(2)
COP
Heating
•
*2 (1)
19,500
22.7
kW
kW
7.7/7.6
9.7/9.7
6.5
9.2
2.92/2.92
2.79/2.74
3.49
3.09
Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
•
17
24,400
kW
28.4
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
18
Simultaneous Operation System—Twin & Triple & Double Twin Multi Application Operation
(For specifications of duct connection series, please refer to P35-P40.)
C ooling Only (60 Hz)
Heat Pump (60 Hz)
Ceiling mounted cassette type
Ceiling mounted cassette type
140
200
250
140
FHYC71KVEX 2
FHYC100KVEX 2
FHYC125KVEX 2
FHYC71KVEX 2
Indoor unit
FHYC71KVEX 3
FHYC50KVEX 3
Model
Outdoor unit
R140KUTALK
Power supply
FHYC60KVEX 4
FHYC50KVEX 4
R200KUTAL
R250KUTAL
R200KUYAL
R250KUYAL
Model
4.5/4.0
6.3/5.7
7.6/6.8
Cooling capacity
Btu/h
53,900/47,800
75,700/68,200
90,800/82,200
*1 (1)/(2)
kcal/h
13,500/12,000
19,100/17,200
22,900/20,700
kW
15.8/14.0
22.2/20.0
26.6/24.1
kW
5.70/6.80
8.20/10.0
10.20/12.5
2.77
2.71
2.61
Power comsumption *1 (1)/(2)
COP *1 (1)
Operation range (Outdoor temp.)
°CDB
21 to 54
Heating capacity
*2 (1)/(2)
COP
Operation range
(Outdoor temp.)
140
FHY71BVEX 2
Indoor unit
200
FHY100BVEX 2
FHY50BVEX 3
Outdoor unit
R140KUTALK
Power supply
RY250KUTAL
RY250KUYAL
Cooling *1 (1)/(2)
kW
Heating *2 (1)/(2)
kW
Cooling *1 (1)
Heating *2 (1)
Cooling
°CDB
Heating
°CWB
4.5/4.0
53,900/47,800
13,500/12,000
15.8/14.0
5.1/4.8
61,900/58,000
15,600/14,600
18.1/17.0
5.7/6.9
5.6/5.7
2.77
3.23
-5 to 54
6.3/5.7
75,800/68,300
19,100/17,200
22.2/20.0
6.4/6.4
77,500/76,500
19,500/19,300
22.7/22.4
8.2/10.0
7.0/7.1
2.71
3.24
7.6/6.8
90,800/82,300
22,900/20,700
26.6/24.1
8.1/8.0
97,000/95,600
24,400/24,100
28.4/28.0
10.2/12.5
9.7/9.9
2.61
2.93
0 to 54
-10 to 15
250
FHY125BVEX 2
RT
FHY50BVEX 4
FHY60BVEX 4
R200KUTAL
R250KUTAL
R200KUYAL
R250KUYAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
6.3/5.7
7.6/6.8
Cooling capacity
Btu/h
4.5/4.0
53,900/47,800
75,700/68,200
90,800/82,200
*1 (1)/(2)
kcal/h
13,500/12,000
19,100/17,200
22,900/20,700
kW
15.8/14.0
22.2/20.0
26.6/24.1
kW
5.70/6.90
5.7/6.9
8.20/10.0
8.2/10.0
10.20/12.5
10.2/12.5
2.77
2.71
2.61
COP *1 (1)
Operation range (Outdoor temp.)
FHYC60KVEX 4
FHY71BVEX 3
Model
Power comsumption *1 (1)/(2)
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
*1 (1)/(2)
Power comsumption
250
FHYC125KVEX 2
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
Cooling capacity
-5 to 54
Ceiling suspended type
FHYC50KVEX 3
RY140KUTALK
Power supply
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
•
Indoor unit
Outdoor unit
200
FHYC100KVEX 2
FHYC50KVEX 4
FHYC71KVEX 3
RY200KUTAL
RY200KUYAL
°CDB
-5 to 54
Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Ceiling suspended type
140
Model
Outdoor unit
Power supply
RT
Cooling capacity
Btu/h
*1 (1)/(2)
kcal/h
kW
RT
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
Heating capacity
Btu/h
*2 (1)/(2)
kcal/h
kW
Power comsumption
COP
Operation range
(Outdoor temp.)
•
Cooling *1 (1)/(2)
200
250
FHY100BVEX 2
FHY125BVEX 2
X
FHY71BVE 3
FHY50BVEX 3
FHY60BVEX 4
FHY50BVEX 4
RY200KUTAL
RY250KUTAL
RY140KUTALK
RY200KUYAL
RY250KUYAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
4.5/4.0
6.3/5.7
7.6/6.8
53,900/47,800
75,700/68,200
90,800/82,200
13,500/12,000
19,100/17,200
22,900/20,700
15.8/14.0
22.2/20.0
26.6/24.1
5.1/4.8
6.4/6.4
8.1/8.0
61,800/58,000
77,500/76,400
96,900/95,500
15,600/14,600
19,500/19,300
24,400/24,100
18.1/17.0
22.7/22.4
28.4/28.0
8.2/10.0
6.0/7.2
10.2/12.5
5.9/6.0
7.0/7.1
9.7/9.9
2.63
2.71
2.61
3.07
3.24
2.93
0 to 54
-5 to 54
-10 to 15
FHY71BVEX 2
Indoor unit
kW
Heating *2 (1)/(2) kW
Cooling *1 (1)
Heating *2 (1)
Cooling
°CDB
Heating
°CWB
Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•
19
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
20
The Intelligent Air Conditioning System
Note: Availability of the products shown in this catalogue varies by country.
Indoor Units.................................24
VRV II Series...............................25
VRV K Series...............................27
VRV II Series
Rising energy and general building services running costs have led end users to
expect a truly complete and acceptable air conditioning system. It must be energy
efficient, economic to run, easy to install, flexible, reliable and user friendly.
Featuring inverter technology and individual control, the VRV system
revolutionised building air conditioning the world over by meeting all these
requirements, and has been installed in various buildings throughout the world for
the last 20 years.
RT
6.4
8.0
12.7
14.3
15.9
19.1
20.7
22.3
23.9
Btu
76400
95500
152900
172000
191100
229300
248400
267500
286600
kW
22.4
28.0
44.8
50.4
56.0
67.2
72.8
78.4
84.0
8
10
16
18
20
24
26
28
30
HP
HRV (Heat Reclaim Ventilation)..28
Control Systems..........................29
Capacity
Line Up
R410A
Series
Heat pump
Type
50 Hz
Heat pump
Type
60 Hz
Note: • Specifications for RT, Btu and kW are based on the following conditions;
Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Capacity Range (HP)
8
VRV K series
Air Treatment Equipment
Air flow rate (m3/h)
HRV
(Heat Reclaim Ventilation)
VAM150
21
VAM250
VAM350
VAM500
VAM650
VAM800
VAM1000
VAM1500
VAM 2000
22
Indoor Units
The
series comprises a wide range of indoor units designed
to meet virtually any installation site requirement.
Indoor units
Ceiling Mounted
Cassette Corner Type
Ceiling Mounted Cassette
<Multi flow> Type
Ceiling Mounted Cassette
<Double flow> Type
Thin, lightweight, and easy to
install in narrow ceiling space
FXCQ-MVE
FXFQ-MVE
FXSQ-MVE
Concealed
Floor Standing Type
Floor Standing Type
Perfect unit for perimeter
zone air conditioning
Sophisticated design and
compact casing harmonized in
any interior décor
Perfect unit to be concealed in
the skirting-wall of perimeter
FXLQ-MVE
FXAQ-MVE
FXHQ-MVE
FXMQ-MVE
FXDQ-NVE(T)*
Wall Mounted Type
Slim body with quieter
and wider air flow
High static pressure allows
flexible duct design
Highly flexible for various
application
Slim design, quietness and
static pressure switching
FXKQ-MVE
Ceiling Suspended Type
Ceiling Mounted Duct Type
Ceiling Mounted
Built-in Type
Slim Ceiling Mounted
Duct Type
Slim design for flexible
installation
New super cassette type
is compact, quiet and
easy to install
FXNQ-MVE
Capacity
*FXDQ-NVE: with a drain-up pump (750 mm lift) as a standard accessory
FXDQ-NVET: without a drain-up pump
Model
name
Type
RT 0.6 ton 0.8 ton
Btu 7500
9600
Index
20
25
HP
0.8 HP 1 HP
1.0 ton 1.3 ton 1.6 ton 2.0 ton 2.6 ton 3.2 ton 4.0 ton 6.4 ton 8.0 ton
12300 15400 19100 24200 30700 38200 47800 76400 95500
31.25
40
50
62.5
80
100
125
200
250
1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP
5 HP
8 HP 10 HP
Ceiling Mounted Cassette (Double flow)
FXCQ-MVE
Ceiling Mounted Cassette (Multi flow) Super Cassette
FXFQ-MVE
Ceiling Mounted Cassette Corner
FXKQ-MVE
Slim Ceiling Mounted Duct
FXDQ-NVE with
drain-up pump
FXDQ-NVET without
drain-up pump
Ceiling Mounted Built-in
FXSQ-MVE
Ceiling Mounted Duct
FXMQ-MVE
Ceiling Suspended
FXHQ-MVE
Wall Mounted
FXAQ-MVE
Floor Standing
FXLQ-MVE
Concealed Floor Standing
FXNQ-MVE
Note: • Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Connection unit series (50 Hz only)
Wall Mounted
New C eiling S us pended
C as s ette
Floor S tanding
FXAQ-MHV1
C onnec tion unit for indoor unit
FXUQ-MV1
FXLQ-MHV1
BEVQ-MVE
Capacity
H/P: Heat Pump Type
Model
name
Type
RT
0.6 ton
Btu
7500
Index
20
HP
0.8 HP
Wall Mounted
FXAQ-MHV1
Floor Standing
FXLQ-MHV1
New Ceiling Suspended Cassette
FXUQ-MV1
Notes: • Specifications for RT and Btu are based on the following conditions;
0.8 ton
9600
25
1 HP
1.0 ton
12300
31.25
1.25 HP
1.3 ton
15400
40
1.6 HP
1.6 ton
19100
50
2 HP
2.3 ton
27300
71
3 HP
3.2 ton
38200
100
4 HP
4.0 ton
47800
125
5 HP
Connectable
Outdoor
Unit
H/P
H/P
H/P
• Indoor units in the 63 class are not available for the above models.
• Connection unit BEVQ-M is necessary for each indoor unit.
Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Cooling Only & Heat Pump
Model
Indoor unit
20
Power supply
Cooling capacity (1)/(2)
Heating capacity
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
0.7/0.6
7,800/7,500
2,000/1,900
2.3/2.2
0.7
8,500
2,200
2.5
25
Notes: • Cooling capacity is based on indoor temp.
(1)27°CDB, 19.5°CWB, and outdoor temp. 35°CDB.
(2)27°CDB, 19.0°CWB, and outdoor temp. 35°CDB.
23
32
40
50
63
71
80
100
125
200
250
1 phase, 220-240 V/220 V, 50/60 Hz
0.8/0.8
1.1/1.0
1.3/1.3
1.6/1.6
2.1/2.0
2.4/2.3
2.6/2.6
3.3/3.2
4.1/4.0
6.5/6.4
8.2/8.0
9,900/9,600 12,600/12,300 16,000/15,400 19,800/19,100 24,900/24,200 28,300/27,300 31,700/30,700 39,600/38,200 49,500/47,800 78,500/76.400 98,300/95,500
2,500/2,400 3,200/3,100 4,000/3,900 5,000/4,800 6,300/6,100 7,100/6,900 8,000/7,700 10,000/9,600 12,500/12,000 19,800/19,300 24,800/24,100
2.9/2.8
3.7/3.6
4.7/4.5
5.8/5.6
7.3/7.1
8.3/8.0
9.3/9.0
11.6/11.2 14.5/14.0 23.0/22.4 28.8/28.0
0.9
1.1
1.4
1.8
2.3
2.6
2.8
3.6
4.5
7.1
8.9
10,900
13,600
17,000
21,500
27,300
30,700
34,100
42,700
54,600
85,300
107,500
2,800
3,400
4,300
5,400
6,900
7,700
8,600
10,800
13,800
21,500
27,100
3.2
4.0
5.0
6.3
8.0
9.0
10.0
12.5
16.0
25.0
31.5
• Heating : Indoor temp. of 20°CDB, of 7°CDB, 6°CWB.
• Equivalent piping length : 7.5 m.
• Level difference : 0 m.
24
Outdoor units (50Hz)
Outdoor units (60Hz)
HEAT PUMP TYPE
HEAT PUMP TYPE
RT
6.4
8.0 12.7 14.3 15.9 19.1 20.7 22.3 23.9
Btu 76400 95500 152900 172000 191100 229300 248400 267500 286600
Series
kW 22.4 28.0 44.8 50.4 56.0 67.2 72.8 78.4 84.0
HP
8
10
16
18
20
24
26
28
30
Heat pump type
8, 10 HP
16, 18, 20 HP
RXYQ8MY1K(E)
RXYQ10MY1K(E)
(50 Hz)
Note: • Specifications for RT, Btu and kW are based on the following conditions;
Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
RXYQ16MY1K(E)
RXYQ18MY1K(E)
RXYQ20MY1K(E)
24, 26, 28, 30 HP
RXYQ24MY1K(E)
RXYQ26MY1K(E)
RXYQ28MY1K(E)
RXYQ30MY1K(E)
Heat Pump Type (50 Hz)
RXYQ8MY1K(E)
Constituent
Units
—
RXYQ10MY1K(E)
RXYQ16MY1K(E)
RXYQ18MY1K(E)
RXYQ20MY1K(E)
—
RXYQ8MY1K(E)
RXYQ8MY1K(E)
RXYQ8MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)
Power supply
Heating capacity
(*5)
MODE
RXYQ8MYLK(E)
RXYQ10MYLK(E)
RXYQ16MYLK(E)
RXYQ18MYLK(E)
RXYQ20MYLK(E)
—
—
RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)
RT
6.6/6.5
8.0/6.8
13.1/13.0
14.6/13.3
16.0/13.7
Btu/h
78,800/77,800
96,200/82,200
157,600/155,600
175,000/160,000
192,400/164,500
Constituent
Units
3 phase, 380 V, 60Hz
13.1/13.0
14.6/13.3
16.0/13.7
Btu/h
78,800/77,800
96,200/82,200
157,600/155,600
175,000/160,000
192,400/164,500
kcal/h
19,900/19,600
24,300/20,700
39,700/39,200
44,100/40,300
48,500/41,500
kcal/h
19,900/19,600
24,300/20,700
39,700/39,200
44,100/40,300
48,500/41,500
kW
23.1/22.8
28.2/24.1
46.2/45.6
51.3/46.9
56.4/48.2
kW
23.1/22.8
28.2/24.1
46.2/45.6
51.3/46.9
56.4/48.2
RT
6.4/6.4
8.0/6.8
12.7/12.7
14.3/13.2
15.9/13.7
RT
6.4/6.4
8.0/6.8
12.7/12.7
14.3/13.2
15.9/13.7
Btu/h
76,400/76,400
95,500/82,200
152,900/152,900
172,000/158,700
191,100/164,500
Btu/h
76,400/76,400
95,500/82,200
152,900/152,900
172,000/158,700
191,100/164,500
kcal/h
19,300/19,300
24,100/20,700
38,500/38,500
43,300/40,000
48,200/41,500
kcal/h
19,300/19,300
24,100/20,700
38,500/38,500
43,300/40,000
48,200/41,500
kW
22.4/22.4
28.0/24.1
44.8/44.8
50.4/46.5
56.0/48.2
kW
22.4/22.4
28.0/24.1
44.8/44.8
50.4/46.5
56.0/48.2
RT
7.1
8.9
14.2
16.0
17.9
RT
7.1
8.9
14.2
16.0
17.9
Btu/h
85,300
107,500
170,600
192,800
215,000
Btu/h
85,300
107,500
170,600
192,800
215,000
Power consumption Cooling (*3)/(*4) kW
Heating (*5)
COP (Cooling) (*1)/(*2)
COP (Cooling) (*3)/(*4)
COP (Heating) (*5)
Cooling
21,500
27,100
43,000
54,200
31.5
50.0
56.5
63.0
7.60/9.58
12.6/18.8
13.9/19.0
15.2/19.2
6.01/9.16
7.58/9.56
12.0/18.3
13.6/18.7
15.2/19.1
Power consumption Cooling (*3)/(*4) kW
Heating (*5)
11.6
13.2
14.8
3.69/2.47
3.71/2.52
COP (Cooling) (*1)/(*2)
3.73/2.45
3.69/2.52
3.73/2.45
3.71/2.48
3.69/2.52
COP (Cooling) (*3)/(*4)
4.30
4.26
4.30
4.27
4.26
-5 to 50
-20 to 16
RXYQ28MY1K(E)
RXYQ30MY1K(E)
RXYQ8MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)
RT
19.7/19.4
21.1/19.8
22.6/20.2
24.0/20.5
Power supply
3 phase, 380–415V, 50Hz
27,100
43,000
50.0
56.5
63.0
12.6/18.8
13.9/19.0
15.2/19.2
6.01/9.16
7.58/9.56
12.0/18.3
13.6/18.7
15.2/19.1
5.82
7.40
11.6
13.2
14.8
3.66/2.42
3.71/2.52
3.66/2.42
3.69/2.47
3.71/2.52
3.73/2.45
3.69/2.52
3.73/2.45
3.71/2.48
3.69/2.52
4.30
4.26
4.30
4.27
4.26
-5 to 50
Heating °CWB
-20 to 16
RXYQ24MYLK(E)
RXYQ26MYLK(E)
RXYQ28MYLK(E)
RXYQ30MYLK(E)
Constituent
Units
RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ10MYLK(E)
RXYQ8MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)
RT
19.7/19.4
21.1/19.8
3 phase, 380 V, 60Hz
22.6/20.2
24.0/20.5
Btu/h
236,500/233,400
253,900/237,800
271,300/242,300
288,700/246,700
59,600/58,800
64,000/59,900
68,400/61,100
72,800/62,200
84.6/72.3
kW
69.3/68.4
74.4/69.7
79.5/71.0
84.6/72.3
23.9/20.5
RT
19.1/19.1
20.7/19.6
22.3/20.1
23.9/20.5
Btu/h
229,300/229,300
248,400/235,100
267,500/240,900
286,600/246,700
kcal/h
57,800/57,800
62,600/59,300
67,400/60,700
72,200/62,200
kW
67.2/67.2
72.8/68.9
78.4/70.6
84.0/72.3
RT
21.3
23.1
25.0
26.8
Btu/h
255,900
278,100
300,300
322,400
236,500/233,400
253,900/237,800
271,300/242,300
288,700/246,700
59,600/58,800
64,000/59,900
68,400/61,100
72,800/62,200
kW
69.3/68.4
74.4/69.7
79.5/71.0
RT
19.1/19.1
20.7/19.6
22.3/20.1
Btu/h
229,300/229,300
248,400/235,100
267,500/240,900
286,600/246,700
kcal/h
57,800/57,800
62,600/59,300
67,400/60,700
72,200/62,200
kW
67.2/67.2
72.8/68.9
78.4/70.6
84.0/72.3
RT
21.3
23.1
25.0
26.8
Btu/h
255,900
278,100
300,300
322,400
75,700
54,200
31.5
7.60/9.58
°CDB
MODE
48,600
25.0
kcal/h
Btu/h
70,100
Cooling
21,500
6.31/9.41
Power supply
kcal/h
64,500
COP (Heating) (*5)
Operation range
RXYQ8MY1K(E)
RXYQ8MY1K(E)
RXYQ10MY1K(E)
Heating (*5)
kW
3.66/2.42
RXYQ26MY1K(E)
Power consumption Cooling (*3)/(*4) kW
kcal/h
Cooling (*1)/(*2)
7.40
RXYQ8MY1K(E)
RXYQ8MY1K(E)
RXYQ8MY1K(E)
kW
Heating capacity
(*5)
3.71/2.52
RXYQ24MY1K(E)
kcal/h
Cooling capacity
(*3)/(*4)
5.82
Constituent
Units
Cooling (*1)/(*2)
Cooling capacity
(*1)/(*2)
3.66/2.42
°CDB
MODEL
48,600
25.0
6.31/9.41
Heating °CWB
Heating capacity
(*5)
RXYQ24MYLK(E)
RXYQ26MYLK(E)
RXYQ28MYLK(E)
RXYQ30MYLK(E)
8.0/6.8
kW
Cooling capacity
(*3)/(*4)
Note: • Specifications for RT, Btu and kW are based on the following conditions;
Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
24, 26, 28, 30 HP
6.6/6.5
kcal/h
Cooling capacity
(*1)/(*2)
16, 18, 20 HP
RXYQ16MYLK(E)
RXYQ18MYLK(E)
RXYQ20MYLK(E)
RT
Cooling (*1)/(*2)
Operation range
8, 10 HP
RXYQ8MYLK(E)
RXYQ10MYLK(E)
(60 Hz)
Power supply
3 phase, 380–415V, 50Hz
Cooling capacity
(*3)/(*4)
RT
6.4
8.0 12.7 14.3 15.9 19.1 20.7 22.3 23.9
Btu 76400 95500 152900 172000 191100 229300 248400 267500 286600
kW 22.4 28.0 44.8 50.4 56.0 67.2 72.8 78.4 84.0
HP
8
10
16
18
20
24
26
28
30
Heat pump type
Series
Heat Pump Type (60 Hz)
MODEL
Cooling capacity
(*1)/(*2)
Capacity
Line Up
Capacity
Line Up
81,300
75.0
81.5
88.0
94.5
18.9/28.2
20.2/28.4
21.5/28.6
22.8/28.7
18.0/27.5
19.6/27.9
21.2/28.3
22.7/28.7
Cooling capacity
(*1)/(*2)
Cooling capacity
(*3)/(*4)
Heating capacity
(*5)
kcal/h
kW
Cooling (*1)/(*2)
Power consumption Cooling (*3)/(*4) kW
64,500
70,100
75,700
81,300
75.0
81.5
88.0
94.5
18.9/28.2
20.2/28.4
21.5/28.6
22.8/28.7
18.0/27.5
19.6/27.9
21.2/28.3
22.7/28.7
17.5
19.0
20.6
22.2
17.5
19.0
20.6
22.2
COP (Cooling) (*1)/(*2)
3.66/2.42
3.68/2.45
3.70/2.49
3.71/2.52
COP (Cooling) (*1)/(*2)
3.66/2.42
3.68/2.45
3.70/2.49
3.71/2.52
COP (Cooling) (*3)/(*4)
3.73/2.45
3.71/2.47
3.70/2.50
3.69/2.52
COP (Cooling) (*3)/(*4)
3.73/2.45
3.71/2.47
3.70/2.50
3.69/2.52
4.30
4.28
4.27
4.26
4.30
4.28
4.27
4.26
COP (Heating) (*5)
Operation range
Cooling
°CDB
Heating °CWB
-5 to 50
-20 to 16
Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins of
the heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;
•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.
(*2) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 46°CDB.
Conversion rates
(*3) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.
(*4) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 46°CDB.
kcal/h = kW x 860
•Heating : (*5) Indoor temp. of 20°CDB, and outdoor temp. 7°CDB/6°CWB.
Btu/h
= kW x 3412
•Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,
RT = kW x 0.284
these values are normally somewhat higher as a result of ambient conditions.
25
Heating (*5)
COP (Heating) (*5)
Operation range
Cooling
°CDB
Heating °CWB
-5 to 50
-20 to 16
Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins of
the heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;
•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.
(*2) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 46°CDB.
Conversion rates
(*3) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.
(*4) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 46°CDB.
kcal/h = kW x 860
• Heating : (*5) Indoor temp. of 20°CDB, and outdoor temp. 7°CDB/6°CWB.
Btu/h = kW x 3412
• Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,
RT = kW x 0.284
these values are normally somewhat higher as a result of ambient conditions.
26
VRV K Series—Outdoor Units
Heat Reclaim Ventilation
The individual control of the air conditioning system for 4–5 rooms can be realized
by more simple and lesser installation work.
The HRV creates a high-quality environment
by interlocking with the air conditioner
Daikin air conditioner
Shops
• Coffee shop and restaurant • Dressmaking
Office
• Super market • Other variety shops
• Office
• Small and medium size office building
• Large house
• Amusement center
• ON/OFF signal
• Cooling/Heating mode signal
• Set temperature signal
• Ventilation signal
• Humidifier ON/OFF signal
Housing
Others
Type
Model
name
Ceiling Mounted Cassette (Double flow)
Ceiling Mounted Cassette (Multi flow) Super Cassette
Ceiling Mounted Cassette Corner
Ceiling Mounted Duct
Ceiling Mounted Built-in
Ceiling Mounted Duct
Ceiling Suspended
Wall Mounted
Floor Standing
Concealed Floor Standing
Capacity
shop
Indoor unit
• Operating mode signal
• Filter cleaning signal
• Failure detection signal
RT
1.0 ton
Btu
12300
Index 31.25
HP
1.25 HP
1.3 ton
15400
40
1.6 HP
1.6 ton
19100
50
2 HP
2.0 ton
24200
62.5
2.5 HP
2.6 ton
30700
80
3.2 HP
3.2 ton
38200
100
4 HP
4.0 ton
47800
125
5 HP
6.4 ton
76500
200
8 HP
FXC-LVE
FXFL-LVE
FXK-LVE
FXYD-KAVE
FXS-LVE
FXM-LVE
FXH-LVE
FXA-LVE
FXL-LVE
FXN-LVE
Daikin's HRV recovers heat energy lost through ventilation and holds
down room temperature changes caused by ventilation, thereby
maintaining a comfortable and clean environment.
The HRV is interlocked to Daikin's
system, SkyAir and other air
conditioning systems and automatically switches over ventilation mode,
further increasing the effects of energy conservation.
Cooling Only & Heat Pump
Indoor unit
31.25
40
Power supply
Cooling capacity (1)/(2)
Heating capacity
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
1.1/1.0
12,600/12,300
3,200/3,100
3.7/3.6
1.1
13,600
3,400
4.0
1.3/1.3
16,000/15,400
4,000/3,900
4.7/4.5
1.4
17,100
4,300
5.0
Notes: Specifications are based on the following conditions;
(1)Cooling : 27°CDB, 19.5°CWB, and outdoor temp. 35°CDB.
(2)Cooling : 27°CDB, 19.0°CWB, and outdoor temp. 35°CDB.
50
62.5
80
100
VE: 1 phase, 220-240/220 V, 50/60 Hz
1.6/1.6
2.1/2.0
2.6/2.6
3.3/3.2
19,800/19,100 24,900/24,200 31,700/30,700 39,600/38,200
5,000/4,800
6,300/6,100
8,000/7,700
10,000/9,600
5.8/5.6
7.3/7.1
9.3/9.0
11.6/11.2
1.8
2.3
2.8
3.6
21,500
27,300
34,100
42,700
5,400
6,900
8,600
10,800
6.3
8.0
10.0
12.5
125
200
4.1/4.0
49,500/47,800
12,500/12,000
14.5/14.0
4.5
54,600
13,800
16.0
6.5/6.4
78,500/76,400
19,800/19,300
23.0/22.4
7.1
85,300
21,500
25.0
• Heating : Indoor temp. of 20°CDB, of 7°CDB, 6°CWB.
• Equivalent piping length : 7.5 m.
• Level difference : 0 m.
Cooling capacity (*1)/(*2)
Heating capacity (*3)
Power comsumption
COP
RSNY8KTAL
22.4kw(8HP)
27
Cooling (*1)/(*2)
Heating
Cooling (*1)/(*2)
Heating
VAM350FAVE
VAM500FAVE
VAM1000FAVE
R emote C ontroller
VAM1500FAVE
VAM2000FAVE
HRV Remote Controller
(50 Hz/60 Hz)
Model
RSNY8KTAL
Power supply
Different capacity and different type
of indoor unit can be connected at
the capacity ratio of 50 to 100% of
the outdoor unit, and up to 6 indoor
units can be connected with
individual control.
First-Class Energy Conservation in the Industry
A total of 28% reduction of air conditioning load has been achieved
through a combined use of total heat exchange mode, linked operation
with an air conditioner, and pre-heat/pre-cool control.
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
Cooling Only & Heat Pump
Outdoor Unit
VAM150FAVE
First-Class Compactness in the Industry has been achieved by employing
a originally developed High Efficiency Paper (HEP) element, and using an
optimized fan and airflow passage design.
Note:• Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Model
HRV
LCD remote controller
for indoor unit
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
3 phase, 220 V, 60 Hz
6.4/7.1
76,400/85,300
19,300/21,500
22.4/25.0
7.1
85,300
21,500
25.0
8.9/8.5
11
2.52/2.94
2.27
Notes: 1. Optional models (-E type) feature components treated for heat and rust corrosion
resistance, such as external panels, fan motor, and electric component box, in
addition to the fins of the heat exchanger. Please contact Daikin for more
information.
2. Specifications are based on the following conditions;
•Cooling: (*1) Indoor temp.: 27.0°CDB, 19.0°CWB, Outdoor temp.: 35.0°CDB
(*2) Indoor temp.: 29.0°CDB, 19.0°CWB, Outdoor temp.: 46.0°CDB
•Heating: (*3) Indoor temp.: 20.0°CDB, Outdoor temp.: 7.0°CDB/6.0°CWB.
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
Model
VAM150FAVE VAM250FAVE VAM350FAVE VAM500FAVE VAM650FAVE VAM800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE
Power supply
Air Flow Rate (m3/h)
[50 Hz/60 Hz]
External Static
Pressure (Pa)
[50 Hz/60 Hz]
Temp. exchange
efficiency (H/L)
Enthalpy exchange
efficiency (H/L)
1 phase, 220-240 V/220 V, 50 Hz/60 Hz
Ultra-High
150/150
250/250
350/350
500/500
650/650
800/800
1,000/1,000
1,500/1,500
2,000/2,000
High
150/150
250/250
350/350
500/500
650/650
800/800
1,000/1,000
1,500/1,500
2,000/2,000
Low
110/110
155/145
230/210
350/300
500/440
670/660
870/800
1,200/1,200
1,400/1,400
Ultra-High
69/98
64/98
98/142
98/147
93/162
137/225
157/196
137/206
137/196
High
39/54
39/54
70/85
54/54
39/69
98/118
98/108
98/118
78/88
Low
20/24
20/20
25/15
25/20
25/34
49/69
78/69
49/69
% 50 Hz (60 Hz) 74/79(74/80)
59/69
72/77(72/77)
75/80(75/81) 74/77(74/78.5) 74/77(74/78)
74/76(74/76) 75/76.5(75/78) 75/78(75/78)
75/78(75/78)
% For heating
50 Hz (60 Hz)
64/69(64/71)
64/68(64/69)
65/70(65/71) 62/67(62/68.5) 63/66(63/68)
65/67(65/68)
66/68(66/71)
66/68(66/68)
66/70(66/70)
% For cooling
50 Hz (60 Hz)
58/64(58/66)
58/62(58/63)
61/67(61/68) 58/63(58/65.5) 58/63(58/65)
60/62(60/63)
61/63(61/66)
61/64(61/64)
61/66(61/66)
28
Control Systems
Control Systems
Individual Control Systems
Centralized Control Systems
Central remote controller (Optional)
Wired remote controller (Optional)
Large liquid crystal screen displays
complete operating status.
Digital display lets you set
temperature in 1°C units.
Lets you individually program by
timer the respective times for
operation start and stop within a
maximum of 72 hours.
Equipped with a thermostat sensor in
the remote controller that makes
possible more comfortable room
temperature control.
Wired remote controller
Constantly monitors malfunctions in
the system for 80 items, and is
equipped with a "self-diagnosis
function" that lets you know by
message immediately when a
malfunction occurs.
Lets you carry out various field
settings by remote controller.
64 groups (zones) of indoor units can be
controlled individually same as LCD Remote controller.
Max.64 groups (128 indoor units controllable)
Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers,
which can control from 2 different places.
Zone control
Malfunction code display
Max. wiring length 1,000 m (Total : 2,000 m)
DCS302C61
Combination with Unified ON/OFF controller, schedule timer and BMS system
Airflow volume and direction can be controlled individually for indoor units in each group operation.
Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (HRV).
Enables you to select cool/heat/fan
operation mode with the indoor
remote controller of your choice
without using the cool/heat selector.
Up to 4 Operation/Stop pairs can be set per day by connecting a schedule timer.
Set back time clock (Optional)
Unified ON/OFF controller (Optional)
Connected to LCD wired remote controller(BRC type), this time clock can set 2 sets
of on/off times in an increment of 30 minutes within a day. For each on/off setting a
16 groups of indoor units can be operated
simultaneously/individually.
temperature setting is also possible.
Max. 16 groups (128 indoor units) controllable
2 remote controllers can be used to control from 2 different places.
Operating status indication (Normal operation, Alarm)
Centralized control indication
Max. wiring length 1,000 m (Total : 2,000 m)
Compact size casing (Thickness : 16 mm)
Combination with Central Remote controller, Schedule timer and BMS system
DCS301B61
Schedule timer (Optional)
Set back time clock
Wireless remote controller (Optional)
Max.128 indoor units can be operated as
programed schedule.
The same operation modes and settings as with wired remote controllers are
possible.
Max. 128 indoor units controllable
When used in combination with a central remote controller, a maximum of 8 weekly schedule
patterns can be set, while the central controller can be used to select desired zones. Up to 4
Operation/Stop pairs can be set per day.
Max. 48 hours back up power supply
Max. wiring length 1,000 m (Total : 2,000 m)
Compact size casing (Thickness : 16 mm)
Combination with Central Remote controller, Unified ON/OFF controller and BMS system
• A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow) type,
ceiling-suspended type and wall-mounted type is mounted into the indoor unit.
Signal receiving unit can be
installed on the panel
ex. Ceiling mounted cassette (multi-flow) type
DST301B61
Signal receiver unit
(Separate type)
Signal receiver unit
Wireless remote
controller
(Installed type)
Part name
Model No.
Simple remote controller (Optional)
Unification adaptor for computerized control
The remote controller has
centralized its frequently used
operation selectors and
switches (on/off, operation
mode, temperature setting and
airflow volume), making itself
suitable for use in hotel rooms
or conference rooms.
DCS302A52
DTA102A52
Interface adaptor for SkyAir series
For SkyAir, FD(Y)M-FA, FDYB-KA, FDY-KA
FVY(P)J-A, FXUQ-MH, FXLQ-MH
DTA107A55
Central control adaptor kit
For UAT(Y)-K(A), FD-K
Concealed type
Exposed type
29
Adaptors required to connect products other than those of
the VRV System to the high-speed DIII-NET
communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be
installed on the product unit to be controlled.
DTA103A51
Wiring adaptor for other air-conditioner
(For hotel use)
Function
Interface between the central monitoring board and central
control units. Combined with the central remote controller,
this adaptor enables the central monitoring board to
centralize such functions as the on/off control, operation
status monitoring, and normal/malfunction monitoring.(*1)
For air conditioners other than mentioned above.
Note : 1. Installation box for
adaptor must be procured on site.
The concealed-type remote controller smartly fits into a
night table or console panel in a hotel room.
30
Control Systems
Daikin's advanced air-conditioning control systems
New
New
Function 4
Air Conditioning
Network Service System
modem for connections
Unification adaptor
for computerized control
[DCS302A52]
Unified ON/OFF and
status monitoring from
the central monitoring panel
Forced OFF contact input
Public phone line
ACC center
• Air Conditioning Network Service System
• CSV output of power
proportional distribution
results (Optional)
Forced OFF from the fire alarm
Dio Unit
PCMCIA
Flash
Memory
New
Function 2
Pi Port
DCS601C51
RS-232C
New
Function 5
D -NET
New
Function 3
Remote monitoring and control
Trouble reports
Trouble reports
Mobile Phone
New
Function 3
DIII-NET
Plus Adapter
(option)
Indoor Unit
Via
internet
e
rad
Upg New
Wiring adaptor required for connection with
other equipment not compatible with D -NET
*
Ai unit
D -NET
Dio unit
DAM602A51/52/53
New
Contact signal
Remote PC
Light/Fan
Daikin Central
Air Conditioning
System
Fire alarm Security
Ethernet
D -NET
VRV System
Local
monitoring
& control
Sub PC
Color LCD touch panel icon display
Small manageable size
Simplified engineering
Multi language (English, French, Italian, German, Spanish and Chinese)
Yearly schedule
P.P.D. (Power Proportinal Distribution function) (Optional)
Auto heat/cool change-over
Temperature limitation
History of 500 actions
Air Conditioning Network Service System (Optional Maintenance Service)
Simple Interlock Function
HRV
New
Function 2
Doubling of number of control points
by adding a D -NET Plus Adapter (Optional)
Support for centralized control from elsewhere
using a PC with a Web browser (Optional)
New
Function 3
Sending of e-mail alerts to a specified address
when malfunctions occur (Optional)
New
Function 4
Built-in modem for connecting to
Airnet Service System (Optional)
New
Function 5
Built-in Ethernet port for connecting to
the Internet or an intranet
Management of facilities / equipment
other than A/C units(Compatible with Dio unit and Di unit)
New
Function 1
New
Function 6
e
rad
Upg New
Function 7
Simple Interlock Function
Centralized control system for easy provision of effective control and
monitoring of VRV system functions
Floor visual navigation
Graphical report
New
D -NET
Multi-PC
New
Function 6
Simple Interlock Function
Function 7
Air Conditioning
1
Network Service System
(Optional Maintenance Service)
D -NET
*2
Monitoring of room
enter/exit sign
Di Unit
HRV
Number of indoor unit expanded from 64 to 128.
WatchDOG
Remote
Control pump,
lighting
New
Function 1
• Connection to power consumption
meter when using power proportional
distribution function. (Optional)
New communication functions in the user-friendly icon-based multilingual
controller simplify centralized control of the VRV system.
N e w F u n c t io n s
Remote intelligent manager
Multi-PC access
Watch dog function for remote error monitoring
Power limit control
Sliding temperature <optional (DAM101A51) unit required>
Automatic heat/cool change-over
ECO mode
Temperature limitation
N e w F u n c t io n s
• Features control and monitoring functions for central
A/C products and an Air Conditioning Network
Service function.
• Using an external contact via DIII-NET, monitors and
controls equipment such as lighting, fans, or
building security systems.
Air Conditioning Network Service System (Optional Maintenance Service)
Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.
Interface for
BACnet ® and LONWORKS®
Integrated control systems that recognize the trend of open control systems
Ethernet
BMS
Compatibility with BMS enhanced by utilizing the international communication standards,
BACnet ® or LONWORKS®.
VRV System
Fire alarm
Security
Elevator
Pump
Lighting
...etc
Power supply facility
HRV
DMS502A51
DMS504B51
®
(Interface for use in BACnet ®) (Interface for use in LONWORKS )
Local Controller
DMS504B51 Interface for use in LONWORKS®
XIF file for confirming of specifications of the units.
Connectable up to 10 outdoor units and 64 indoor unit groups.
Please contact Daikin for compatibility with BMS system
DMS502A51 Interface for use in BACnet ®
Air Conditioning
Network Service System
*5
I/F unit
Maintenance services that boost profits
and customer satisfaction
24 hour on-line diagnostic system
Energy saving and extention of aircon operating life
Maintenance management via A/C network service system reports
Reliable service at shortest lead time
Conformance class 3 (ASHRAE 135–1995)
Standard BACnet ® Device B-ASC (ASHRAE 135–2001)
Automatic data transfer
BACnet ® OPC server compatibility
BACnet ®/IP over Ethernet
INTERNET
ACC center
Mainfunction information
by E-mail
Up to 40 outdoor units and 256 indoor uit groups on one gateway. (optional adapter)
Local dealers
are restrictions in applicable areas and release times, therefore please consult us separately for details.
*1.2. There
name varies upon the system size.
*3. Model
trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
* BACnet is aisregistered
a registered trade mark of Echelon Corporation.
*4.5. LForONWanORKS
one of the following can be selected: L oc al C ontroller, intelligent touch Controller, or intelligent Manager II.
*6. EthernetI/Fisunit,
a registered trademark of Xerox Corporation.
*
®
®
31
32
PACKAGEDAIR CONDITIONERS
Note: Availability of the products shown in this catalogue varies by country.
Packaged air conditioners
Air Cooled Packaged Air Conditioners
Duct Connection Series....................................... 35
Air Cooled Single Packaged Air Conditioners...... 41
Air Cooled Packaged Water Chillers....................42
Line Up
Daikin’s duct connection type packaged air conditioners are the best choice
for stores and offices. By placing the air conditioner in the ceiling, the design
and finish of all areas remain attractive and unblemished. With minimal
operating sound, people nearby are almost unaware of the unit’s presence.
And simultaneous operation of 2 to 4 indoor units with a single outdoor unit is
possible. When indoor units are distributed taking sunlight and human
occupation patterns into consideration, a comfortable air flow is effectively
spread throughout the room.
Air cooled packaged water chillers are also available.
Such systems can easily meet all the air-conditioning requirements of
factories and other large areas.
Type
Model Name
Air cooled
packaged
duct connection
series
Low static
pressure type
FDBG
Air cooled
packaged
duct connection
series
Middle static
pressure type
FDMG
Air cooled
packaged
duct connection
series
High static
pressure type
Air cooled
single packaged
air conditioners
Roof top type
FDB
Capacity
PACKAGEDAIR CONDITIONERS
RT
Btu
kW
HP
1.6
1.8
2.3
3.2
4.1
4.5
6.8
8.3
13.6 16.6 27.5
19100 22200 27600 38900 48800 53900 81900 99600 163400 199300 331000
5.6
6.5
8.1
11.4 14.3 15.8 24.0 29.2 47.9 58.4 97.1
2
2.5
3
4
5
6
8
10
15
20
30
50 Hz
C/O
60 Hz
50 Hz
FDYB
FD(Y)M
H/P
60 Hz
50 Hz
C/O
Simultaneous
operation
system
60 Hz
50 Hz
FDM
H/P
FD
C/O
FDY
H/P
UAT
C/O 50 Hz
60 Hz
UATY
H/P 50 Hz
60 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
Note: •Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
•The values given for 2 HP to 3 HP are for the FDB model, 4 HP to 6 HP are for the FDM model and 8 HP to 20 HP are for the FD model.
The values given for 30 HP are for the UAT model and based on the following conditions; Power supply: 50 Hz; Cooling: Indoor temp. of 27°C DB, 19.5°C WB, and outdoor temp. of 35.0°C DB.
WATER CHILLERS
Type
Air cooled
packaged
water chillers
33
HP
kW
Model Name
2
50
2.5
100
3
150
4
200
5
250
6
300
7.5
400
10
500
15
600
20
700
30
800
50 Hz
UWA
C/O
60 Hz
34
PACKAGEDAIR CONDITIONERS
Air Cooled Packaged Air Conditioners—FD(Y)B(G) Series
Air Cooled Packaged Air Conditioners—FD(Y)M Series
Duct Connection Series Low Static Pressure Type
Duct Connection Series Middle Static Pressure Type
Perfect for quiet, beautiful, living spaces
like condominiums and apartments,
houses and hotels, and similar living areas
Main unit can be mounted
in the ceiling, and air can be
delivered freely by duct.
Whisper Quiet
Durable
Indoor unit with the industry's lowest level of sound
Handy
FDBG60/71AVE
FDB60/71KVE
FDBG50AVE
FDB50KVE
Small, lightweight and easy-to-install outdoor unit
FDMG71AV1
Durable
The special acryl precoated fin (PE fin) for anti-corrosion
treatment on the outdoor unit heat exchanger ensures
greater resistance against salt damage and atmospheric
pollution than ever.
Easy to read LCD wired remote
controller. (Optional accessory)
(FDYM only)
FDYB50KAVE
R emote C ontroller
For FDMG models
Outdoor Unit
For FD(Y)M models
Central control
FDYB60/71KAVE
Many options are available for use with
large-scale and advanced-function
centrally controlled systems.
(FDYM only)
Easy to read LCD wired remote controller (Optional
accessory for heat pump type) (FDYB only)
R emote C ontroller
FD(Y)M04FAVAL
FDYM05/06FAVAL
FD(Y)M03FAVAL
Easy to Use
Easy to Use
FDMG100/125AV1
The special acryl precoated fin (PE fin)
for anti-corrosion treatment on the
outdoor unit heat exchanger ensures
greater resistance against salt damage
and atmospheric pollution than ever.
LCD wired
remote
controller
Digital Remote
Controller
Signal
Receiver
Unit
Outdoor Unit
For Cooling Only Type
Remote
Controller
For Heat Pump Type
Wireless Remote
Controller
Cooling Only (50 Hz)
Digital Remote
Controller
Remote
Controller
LCD Wired
Remote
Controller
Signal
Receiver
Unit
Indoor unit
Model
Wireless Remote Controller
(Only for Heat Pump)
Cooling Only (50 Hz)
50
60
71
Indoor unit
FDBG50AVE
FDBG60AVE
FDBG71AVE
Outdoor unit
R50GV1
R60GV1K
Cooling capacity
*1 (1)/(2)
Power comsumption *1 (1)/(2)
COP *1 (1)/(2)
Operation range (Outdoor temp.)
°CDB
Cooling Only (60 Hz)
Model
Outdoor unit
Power Supply
*1 (2)/(3)
Heating capacity
*2 (1)/(2)
Power comsumption
COP
Operation range
(Outdoor temp.)
Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling*1 (2)
Heating *2 (1)
Cooling
Heating
R71FUV1
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
°CDB
°CWB
Model
R100FUV1
R125FUV1
R71AY1
R100FUY1
2.5/2.5
30,000/29,700
7,600/7,500
8.80/8.7
3.15/3.13
2.79/2.78
V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
3.0/3.0
36,200/35,800
9,100/9,000
10.6/10.5
4.08/4.04
2.60/2.60
21 to 52
°CDB
3.7/3.7
44,700/44,000
11,200/11,000
13.1/12.9
4.89/4.85
2.68/2.66
71
100
125
140
Indoor unit
FDM03FAVAL
FDM04FAVAL
FDM05FAVAL
FDYM06FAVAL
Outdoor unit
R71FUVAL
R100FUVAL
R125FUTAL
R140KUTALK
Power Supply
Cooling capacity
*1 (2)/(3)
Power comsumption *1 (2)/(3)
COP *1 (2)
Operation range (Outdoor temp.)
50
60
71
50
60
71
FDB60KVE
FDB71KVE
FDYB50KAVE
FDYB60KAVE
FDYB71KAVE
R50GVAL
R60GVAL
R71FUVAL
RY50GVAL
RY60GVAL
RY71FUVAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz
1.6/1.5
1.8/1.6
2.3/2.0
19,800/17,400
21,800/19,500
27,600/24,600
4,990/4,390
5,500/4,910
7,000/6,200
5.80/5.11
6.40/5.71
8.10/7.20
1.8/1.8
2.0/2.0
2.6/2.6
21,500/21,300
24,500/24,300
30,700/30,700
5,420/5,370
6,180/6,140
7,700/7,700
6.30/6.25
7.19/7.13
9.00/9.00
2.20/2.50
2.70/3.30
3.50/4.20
2.00/2.02
2.44/2.50
3.30/3.30
2.64
2.37
2.31
3.15
2.95
2.73
19.4 to 54
-5 to 54
-10 to 15
-10 to 15.5
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
• Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.
35
R71AV1
Cooling Only (60 Hz)
FDB50KVE
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz
1.8/1.6
2.3/1.9
1.6/1.4
19,100/17,100
22,200/19,100
27,600/22,900
4,820/4,300
5,590/4,800
7,000/5,800
5.60/5.0
6.50/5.6
8.10/6.7
—
—
—
—
—
—
—
—
—
—
—
—
2.10/2.41
2.70/3.29
3.30/3.78
—
—
—
2.67
2.41
2.45
—
—
—
19.4 to 54
21 to 54
—
—
—
RT
Btu/h
kcal/h
kW
kW
R71FUY1
Heat Pump (60 Hz)
Indoor unit
Cooling capacity
Power comsumption *1 (1)/(2)
COP *1 (1)/(2)
Operation range (Outdoor temp.)
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
1.5/1.5
2.0/2.0
2.2/2.2
18,200/18,100
24,000/23,800
26,600/26,300
4,590/4,560
6,050/6,000
6,700/6,600
5.34/5.30
7.03/6.97
7.80/7.70
2.06/2.05
2.76/2.75
2.82/2.8
2.59/2.59
2.55/2.53
2.77/2.75
19.4 to 54
21 to 52
RT
Btu/h
kcal/h
kW
kW
125
FDMG125AV1
Outdoor unit
*1 (1)/(2)
Power Supply
100
FDMG100AV1
Power Supply
Cooling capacity
Model
71
FDMG71AV1
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
RT
Btu/h
kcal/h
kW
kW
2.3/1.9
27,600/22,900
7,000/5,800
8.10/6.7
3.44/3.92
2.35
°CDB
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
3.2/2.6
4.1/3.6
38,900/30,700
48,800/42,700
9,800/7,700
12,300/10,800
11.40/9.0
14.3/12.5
4.61/5.27
6.25/7.10
2.47
2.29
21 to 54
4.5/4.0
53,900/47,800
13,500/12,000
15.8/14.0
5.80/7.00
2.72
Heat Pump (60 Hz)
Model
71
100
125
140
Indoor unit
FDYM03FAVAL
FDYM04FAVAL
FDYM05FAVAL
FDYM06FAVAL
Outdoor unit
RY71FUVAL
RY100FUVAL
RY125FUTAL
RY140KUTALK
Power Supply
Cooling capacity
*1 (2)/(3)
Heating capacity
*2(1)/(2)
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
2.3/1.9
27,600/22,900
7,000/5,800
8.1/6.7
2.6/2.4
30,700/29,000
7,700/7,300
9.00/8.50
3.82/4.37
3.57/3.59
2.12
2.52
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
3.2/2.6
4.1/3.6
38,900/30,700
48,800/42,700
9,800/7,700
12,300/10,800
11.4/9.0
14.3/12.5
3.6/3.4
4.6/4.3
43,700/40,300
55,300/51,200
11,000/10,100
13,900/12,900
12.80/11.80
16.20/15.00
4.76/5.25
6.05/6.71
4.49/4.51
5.56/5.60
2.39
2.36
2.85
2.91
-5 to 54
-10 to 15.5
Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling *1 (2)
COP
Heating *2 (1)
Operation range Cooling
°CDB
(Outdoor temp.) Heating
°CWB
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2:Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
• Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.
• For FDMG models, capacities show gross capacities which do not include a deduction for evaporator fan motor heat.
Power comsumption
4.5/4.0
53,900/47,800
13,500/12,000
15.8/14.0
5.1/4.8
61,800/58,000
15,600/14,600
18.10/17.00
5.80/7.00
5.80/5.90
2.72
3.12
-10 to 15
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
36
PACKAGEDAIR CONDITIONERS
Air Cooled Packaged Air Conditioners—FD(Y) Series
Duct Connection Series High Static Pressure Type
Heat Pump (50 Hz)
Recommended for spacious and large-volume areas because of
its flexible installation. Suitable for large stores, factories, and
other large areas, and for use with housing ducts in homes.
Model
200
250
Indoor unit
FDY08KAY1
FDY10KAY1
FDY15KAY1
FDY20KAY1
Outdoor unit
RY200KUY1
RY250KUY1
RY200KUY1X 2
RY250KUY1X 2
76,800/75,700
6.4/6.3
76,800/75,700
19,300/19,100
22.5/22.2
23.2
6.6
79,200
20,000
23.2
7.2/7.1
76,800/75,700
6.1
19,300/19,100
3.13/3.13
23.2
3.8
Y1: 3 phase, 380-415 V (4 wires), 50 Hz
94,200/92,500
7.8/7.7
150,000/148,000
12.5/12.4
94,200/92,500
150,000/148,000
150,100/148,400
23,700/23,300
37,800/37,400
27.6/27.1
44.0/43.5
29.5
8.4
44.8
12.7
100,700
153,000
152,900
25,400
38,500
29.5
44.8
9.3/9.2
14.4/14.2
94,200/92,500
8.8
150,000/148,000
12.2
23,700/23,300
2.97/2.95
37,800/37,400
3.06/3.06
29.5
3.35
44.8
3.67
184,000/181,000
15.3/15.1
184,000/181,000
183,900/180,800
46,400/45,600
53.9/53.0
56.8
16.1
194,000
193,800
48,800
56.8
18.5/18.3
184,000/181,000
17.6
46,400/45,600
2.91/2.90
56.8
3.23
Power Supply
Highly Adaptable Installation
Cooling capacity
High static pressure and long piping enable flexible
installation and use wherever the unit is placed.
*1 (1)/(2)
Compact
FD03KY1
FD03KVAL
Space-saving outdoor unit also enables lateral
connection.
FD04KY1
FD04KVAL
FD05KY1
FD05KTAL
Heating capacity
*2(1)
Durable
Power comsumption
Highly durable outdoor unit employs PE fins, resists
salt damage and atmospheric pollution.
COP
Cooling*1 (2)/(3)
Heating*2 (1)
Cooling*1 (1)/(2)
Heating *2 (1)/(2)
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
400
500
Super Quiet
Indoor unit with the industry's lowest level of sound.
FD06KY1
FD06KTAL
Central control
FD(Y)08K(A)Y1
FD(Y)08K(A)TAL·YAL
FD(Y)10K(A)Y1
FD(Y)10K(A)TAL·YAL
Heat Pump (60 Hz)
Many options are available for use with large-scale
and advanced-function centrally controlled
systems.
Indoor unit
Model
Outdoor unit
200
250
FDY08KATAL
FDY10KATAL
FDY15KATAL
FDY20KATAL
FDY08KAYAL
FDY10KAYAL
FDY15KAYAL
FDY20KAYAL
RY200KUTAL
RY200KUYAL
Power Supply
FD(Y)15KAY1
FD(Y)15KATAL·YAL
R emote C ontroller
Cooling capacity
FD(Y)20KAY1
FD(Y)20KATAL·YAL
*1 (2)/(3)
Outdoor Unit
Heating capacity
*2(1)/(2)
Power comsumption
Signal
Receiver
Unit
COP
LCD wired
remote controller
(Only for Heat Pump)
Wireless Remote Controller
(Only for Heat Pump)
Operation range
(Outdoor temp.)
Remote
Controller
(Only for Cooling Only)
Cooling Only (50 Hz)
Model
71
100
125
140
200
250
400
500
Indoor unit
FD03KY1
FD04KY1
FD05KY1
FD06KY1
FD08KY1
FD10KY1
FD15KY1
FD20KY1
Outdoor unit
R71FUY1
R100FUY1
R125FUY1
RU06KY1
RU08K(U)Y1
RU10K(U)Y1
RU08K(U)Y1X 2 RU10K(U)Y1X 2
2.3/2.2
27,600/27,000
7,000/6,800
8.1/7.9
2.5/2.48
3.24/3.19
3.1/3.1
37,500/36,800
9,500/9,300
11.0/10.8
3.52/3.48
3.13/3.10
4.0/3.9
47,800/47,100
12,000/11,800
14.0/13.8
4.19/4.15
3.34/3.33
8.4/8.3
101,300/99,600
25,500/25,100
29.7/29.2
9.9/9.8
3.00/2.98
13.8/13.6
16.8/16.6
165,800/163,400 202,300/199,300
41,800/41,200
51,000/50,200
48.6/47.9
59.3/58.4
15.0/14.8
19.8/19.6
3.24/3.24
2.99/2.98
Power Supply
Cooling capacity
*1 (1)/(2)
Power comsumption *1 (1)/(2)
COP *1 (1)/(2)
Operation range (Outdoor temp.)
RT
Btu/h
kcal/h
kW
kW
°CDB
Y1: 3 phase, 380-415 V, 50 Hz
4.9/4.9
6.9/6.8
59,400/58,700
82,900/81,900
15,000/14,800
20,900/20,600
17.4/17.2
24.3/24.0
5.7/5.7
7.5/7.4
3.05/3.02
3.24/3.24
21 to 52
Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling*1 (2)
Heating *2 (1)
Cooling
Heating
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
°CDB
°CWB
6.3/5.6
75,700/67,600
19,100/17,000
22.2/19.8
6.6/6.5
79,200/78,100
20,000/19,700
23.2/22.9
7.7/9.4
6.6/6.7
2.88
3.52
400
500
RY250KUTAL
RY200KUTALX 2
RY250KUTALX 2
RY250KUYAL
RY200KUYALX 2
RY250KUYALX 2
TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
7.7/6.9
12.4/11.0
92,500/82,900
148,400/132,000
23,300/20,900
37,400/33,300
27.1/24.3
43.5/38.7
8.4/8.3
12.7/12.7
100,700/99,300
152,900/152,200
25,400/25,000
38,500/38,400
29.5/29.1
44.8/44.6
9.7/11.9
15.3/18.8
9.3/9.5
13.2/13.4
2.79
2.84
3.17
3.39
0 to 54
-10 to 15
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
15.1/13.4
180,800/161,400
45,600/40,700
53.0/47.3
16.1/16.1
193,800/193,100
48,800/48,700
56.8/56.6
19.4/23.8
18.6/19.0
2.73
3.05
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
Cooling Only (60 Hz)
71
Model
100
125
140
200
Indoor unit
FD03KVAL
FD04KVAL
FD05KTAL
FD06KTAL
FD08KTAL
Outdoor unit
R71FUVAL
R100FUVAL
R125FUTAL
RU06KTAL
RU08K(U)TAL
2.4/2.0
29,000/24,200
7,300/6,100
8.5/7.1
3.22/3.70
2.64
3.4/2.6
40,600/30,700
10,200/7,700
11.9/9.0
4.37/5.02
2.72
21 to 54
Power Supply
Cooling capacity
*1 (2)/(3)
Power comsumption *1 (2)/(3)
COP *1 (2)
Operation range (Outdoor temp.)
RT
Btu/h
kcal/h
kW
kW
°CDB
250
400
500
FD10KTAL
FD15KTAL
FD20KTAL
RU10K(U)TAL RU08K(U)TALX 2 RU10K(U)TALX 2
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
4.3/4.0
4.9/4.5
6.8/6.2
8.3/7.6
51,900/48,100
59,000/53,600
81,900/74,700
99,600/91,100
13,100/12,100
14,900/13,500
20,600/18,800
25,100/23,000
15.2/14.1
17.3/15.7
24.0/21.9
29.2/26.7
5.88/6.73
6.50/7.90
8.30/10.10
10.30/12.60
2.59
2.66
2.89
2.83
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
37
13.6/12.4
16.6/15.1
163,400/149,400 199,300/181,900
41,200/37,700
50,200/45,800
47.9/43.8
58.4/53.3
16.60/20.20
20.60/25.30
2.89
2.83
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
38
PACKAGEDAIR CONDITIONERS
Simultaneous Operation System—Twin, Triple & Double Twin Multi Application Operation
Simultaneously operates 2 to 4 indoor units using
a single outdoor unit.
Heat Pump (50 Hz)
Model
Indoor unit
FDYM04FAV1X 2
FDYM05FAV1X 2
FDYM03FAV1X 3
Outdoor unit
RY200KUY1
RY250KUY1
RY200KUY1
Power Supply
In large interior spaces a single indoor unit may not be able to provide uniform comfort. Installation of 2 to 4 units, distributed to
consider sun light and human gathering patterns, can provide an effective solution.
Installing multiple units is economical and ensures comfort
Cooling capacity
*1(1)/(2)
Heating capacity
In a single-floor restaurant, for example, positioning 4 units at strategic locations achieves comfortable air flow that reaches
every inch of the room.
Lower cost of installation than for individual pair type
*2(1)
Power comsumption
COP
Less space needed for outdoor units
Cooling*1 (1)/(2)
Heating*2 (1)
Cooling*1 (1)/(2)
Heating *2 (1)
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
7.7/7.6
6.4/6.3
76,800/75,700
92,500/90,800
76,800/75,700
19,400/19,100
23,300/22,900
19,400/19,100
22.5/22.2
27.1/26.6
22.5/22.2
6.4
8.1
6.4
77,500
96,900
77.500
19,500
24,400
19,500
22.7
28.4
22.7
7.7/7.6
9.9/9.9
8.0/7.9
6.5
9.4
6.8
2.92/2.92
2.69/2.74
2.81/2.81
3.49
3.02
3.34
Enhanced comfort from distributed indoor units
Cooling Only (60 Hz)
Note: This type of system does not allow individual control or independent operation of indoor units. It is not the best choice for large rooms with partitions.
Indoor unit
Model
Twin Multi Application
Triple Multi Application
Double Twin Multi Application
Outdoor unit
*1(2)/(3)
Branch piping kit
Branch piping kit
250
200
FDYM05FAVALX 2
FDYM03FAVALX 3
R200KUTAL
R250KUTAL
R200KUTAL
R200KUYAL
R250KUYAL
R200KUYAL
6.3/5.7
75,700/68,200
19,100/17,200
22.0/20.0
8.2/10.0
2.71
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
7.6/6.8
90,800/82,200
22,900/20,700
26.6/24.1
10.4/12.7
2.56
-5 to 54
6.3/5.7
75,700/68,200
19,100/17,200
22.2/20.0
8.5/10.3
2.61
Power Supply
Cooling capacity
Power comsumption *1 (2)/(3)
COP *1 (2)
Operation range (Outdoor temp.)
Branch piping kit
200
FDYM04FAVALX 2
RT
Btu/h
kcal/h
kW
kW
°CDB
Branch piping kit
Heat Pump (60 Hz)
200
Model
FDYB60KAVEX 4
FDYB71KAVEX 3
RY250KUTAL·YAL
RY200KUTAL·YAL
Cooling capacity
Model
*1(2)/(3)
200
250
200
Indoor unit
FDYM04FAV1X 2
FDYM05FAV1X 2
FDYM03FAV1X 3
Outdoor unit
R200KUY1
R250KUY1
R200KUY1
6.4/6.3
76,800/75,700
19,400/19,100
22.5/22.2
7.7/7.6
2.92/2.92
V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
7.7/7.6
92,500/90,800
23,300/22,900
27.1/26.6
9.9/9.9
2.74/2.69
-5 to 52
6.4/6.3
76,800/75,700
19,400/19,100
22.5/22.2
8.0/7.9
2.81/2.81
Power Supply
RT
Btu/h
kcal/h
kW
kW
Cooling capacity
*1(1)/(2)
Power comsumption *1 (1)/(2)
COP *1 (1)/(2)
Operation range (Outdoor temp.) °CDB
200
FDYB50KAVEX 4
RY200KUTAL·YAL
Power Supply
Cooling Only (50 Hz)
250
Indoor unit
Outdoor unit
Heating capacity
*2(1)/(2)
Power comsumption Cooling*1 (2)/(3)
Heating*2 (1)/(2)
COP
Cooling*1 (2)
Heating *2 (1)
Operation range Cooling
(Outdoor temp.) Heating
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
°CDB
°CWB
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
6.3/5.7
7.6/6.8
6.3/5.7
75,700/68,200
90,800/82,200
75,700/68,200
19,100/17,200
22,900/20,700
19,100/17,200
22.2/20.0
26.6/24.1
22.2/20.0
6.4/6.4
8.1/8.0
6.4/6.4
77,500/76,400
96,900/95,500
77,500/76,400
19,500/19,300
24,400/24,100
19,500/19,300
22.7/22.4
28.4/28.0
22.7/22.4
8.2/10.0
10.2/12.6
8.20/10.00
7.0/7.1
9.7/10.0
7.0/7.1
2.71
2.61
2.71
3.24
2.93
3.24
0 to 54
-10 to 15
Heat Pump (60 Hz)
Heat Pump (50 Hz)
Model
Indoor unit
FDYB50KAVEX 4
FDYB71KAVEX 3
FDYB60KAVEX 4
Outdoor unit
RY200KUY1
RY200KUY1
RY250KUY1
Power Supply
Cooling capacity
*1(1)/(2)
Heating capacity
*2(1)
Power comsumption
COP
Cooling*1 (1)/(2)
Heating*2 (1)
Cooling*1 (1)/(2)
Heating *2 (1)
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
6.4/6.3
7.7/7.6
76,800/75,700
76,800/75,700
92,500/90,800
19,400/19,100
19,400/19,100
23,300/22,900
22.5/22.2
22.5/22.2
27.1/26.6
6.4
6.4
8.1
77,500
77,500
96,900
19,500
19,500
24,400
22.7
22.7
28.4
7.7/7.6
7.7/7.6
9.7/9.7
6.5
6.5
9.2
2.92/2.92
2.92/2.92
2.79/2.74
3.49
3.49
3.09
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
39
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
Model
200
250
200
Indoor unit
FDYM04FAVALX 2
FDYM05FAVALX 2
FDYM03FAVALX 3
Outdoor unit
RY200KUTAL·YAL
RY250KUTAL·YAL
RY200KUTAL·YAL
Power Supply
Cooling capacity
*1(2)/(3)
Heating capacity
*2(1)/(2)
RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW
Power comsumption Cooling*1 (2)/(3)
Heating*2 (1)/(2)
COP
Cooling*1 (2)
Heating *2 (1)
Operation range Cooling
°CDB
(Outdoor temp.) Heating
°CWB
6.3/5.7
75,700/68,200
19,100/17,200
22.2/20.0
6.4/6.4
77,500/76,400
19,500/19,300
22.7/22.4
8.2/10.0
7.0/7.1
2.71
3.24
VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
7.6/6.8
90,800/82,200
22,900/20,700
26.6/24.1
8.1/8.0
96,900/95,500
24,400/24,100
28.4/28.0
10.4/12.5
9.9/10.1
2.56
2.87
0 to 54
-10 to 15
Notes: •*1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
6.3/5.7
75,700/68,200
19,100/17,200
22.2/20.0
6.4/6.4
77,500/76,400
19,500/19,300
22.7/22.4
8.5/10.3
7.3/7.4
2.61
3.11
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284
40
PACKAGEDAIR CONDITIONERS
WATER CHILLERS
Air Cooled Single Packaged Air Conditioners—UAT(Y) Series
Air Cooled Packaged Water Chillers—UWA Series
Roof Top Type
Easy to install on rooftop or veranda, requiring only ducting,
power line and drain piping.
In addition to its high efficiency, the scroll compressor is 10%
lighter and 30% more compact than conventional
reciprocating compressors. This makes this series among the
industry's most lightweight and compact than previous models.
Also, since the scroll compressor generates less vibration, this
series has greatly improved its durability and achieved the
industry's lowest operation sound. (UAT(Y)-K Series)
UAT08 ·09 ·10·12KA
UATY08 ·09 ·10·12K
UAT06KA
UATY06K
Efficient cross fin coils are used: the unique waffle louver
fins*1 maximize heat exchange efficiency, while the Hi-XA
copper tube*2, featuring an inner spiral groove, fully exploits
refrigerant turbulence to help increase heat exchange
efficiency. The result is substantial energy savings.
UWA55JAY1
UWA138JY1
Wide Operation Range:
UWA80JATJ
Energy saving.
U.S. PAT. *1; No.4,434,844 *2; No.4,480,684
R emote C ontroller
Digital Remote Controller
UAT30H
UAT15 ·18·21KA
UATY15 ·18·21K
Remote Controller
(Only for Cooling Only)
Cooling Only (50 Hz/60 Hz)
UAT06KAY1 UAT08KAY1 UAT09KAY1
UAT06KATAL UAT08KATAL UAT09KATAL
UAT06KAYAL UAT08KAYAL UAT09KAYAL
Model
UAT12KATAL UAT15KAY1 UAT18KAY1 UAT21KAY1
UAT10KAY1
UAT12KAYAL UAT15KATAL UAT18KATAL UAT21KATAL
(50 Hz Only)
(60 Hz Only) UAT15KAYAL UAT18KAYAL UAT21KAYAL
UAT30HY1
UAT30HTO
Power Supply
Y1: 3 phase, 380-415 V, 50 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz/TO: 3 phase, 200/200-220 V, 50/60 Hz
RT
5
6
7.5
9
10
12.5
15
17.5
27.5/30
Cooling capacity *1
Btu/h
60,300
75,000
90,000
107,200
120,000
150,000
180,000
210,400
331,000/368,000
(50/60 Hz)
kcal/h
15,200
18,900
22,700
27,000
30,200
37,800
45,300
53,000
83,500/92,600
kW
17.7
22.0
26.4
31.4
35.1
43.9
52.7
61.6
97.1/107.7
Btu/h
52,900
67,600
81,200
96,600
107,800
135,200
162,100
189,400
284,000/330,700
Cooling capacity *2
(50/60 Hz)
kW
15.5
19.8
23.8
28.3
31.6
39.6
47.5
55.5
83.1/96.9
TAL
8.26
9.74
9.18
—
8.86
9.52
8.64
8.98
—
EER *3
(Cooling)
YAL
8.28
9.78
9.21
—
8.94
9.52
8.64
9.00
—
Operation range (Outdoor temp.)
°CDB
21 to 52 (UAT06KAY1/TAL/YAL–UAT21KAY1/TAL/YAL, UAT30HY1)
Notes: 1. The above data marked with *1 are rated in accordance with JIS C-9612. 27°CDB (80°FDB)/ 19.5°CWB (67°FWB) indoor temp. And 35°CDB (95°FDB) outdoor temp.
2. The above data marked with *2 are rated in accordance with SSA-385/386, 29°CDB (84°FDB)/ 19°CWB (66°FWB) indoor temp. And 46°CDB (115°FDB) outdoor temp.
3. The figures of *2 are reference value.
Net capacity (Btu/h)
4. Capacity (*1, 2) is gross capacity which does not include a deduction for evaporator fan motor heat.
EER =
5. *3: EER conditions: 27°CDB (80°FDB) and 19.5°CWB (67°FWB) for indoor temp. 35°CDB (95°FDB) for outdoor temp.
Unit power comsumption (W)
(Compressor + Outdoor fan motor)
UATY06KY1
UATY06KTAL
UATY06KYAL
Model
Power Supply
Cooling capacity *2
(50/60 Hz)
Heating capacity *3
(50/60 Hz)
EER *3
(Cooling)
EER *4
(Heating)
Power comsumption *1
(Cooling)
Power comsumption
(Heating)
RT
Btu/h
kcal/h
kW
Btu/h
kW
Btu/h
kcal/h
kW
TAL
YAL
TAL
YAL
Y1
kW
TAL
YAL
Y1
TAL
YAL
kW
5
60,300
15,200
17.7
52,900
15.5
62,000
15,600
18.1
8.26
8.28
9.45
9.47
5.8
6.8
6.8
5.3
6.2
6.2
UATY08KY1
UATY08KTAL
UATY08KYAL
UATY09KY1
UATY09KTAL
UATY09KYAL
UATY10KY1
(50 Hz Only)
UATY12KTAL
UATY12KYAL
(60 Hz Only)
UATY15KY1
UATY15KTAL
UATY15KYAL
UATY18KY1
UATY18KTAL
UATY18KYAL
Y1: 3 phase, 380-415 V, 50 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
6
7.5
9
10
12.5
15
75,000
90,000
107,200
120,000
150,000
180,000
18,900
22,700
27,000
30,200
37,800
45,300
22.0
26.4
31.4
35.1
43.9
52.7
67,600
81,200
96,600
107,800
135,200
162,100
19.8
23.8
28.3
31.6
39.6
47.5
78,600
91,700
109,600
123,000
157,200
185,000
19,800
23,100
27,600
31,000
39,600
46,600
23.0
26.9
32.1
36.1
46.1
54.2
9.74
9.18
—
8.86
9.52
8.64
9.78
9.21
—
8.94
9.52
8.64
11.44
10.22
—
9.81
11.23
9.74
11.49
10.25
—
9.87
11.24
9.74
6.3
8.2
9.9
—
13.0
17.1
6.8
8.9
—
11.8
13.6
18.6
6.8
8.9
—
11.8
13.6
18.6
5.7
7.7
9.4
—
11.8
15.8
5.7
8.3
—
11.3
12.4
17.4
5.7
8.3
—
11.3
12.4
17.4
UATY21KY1
UATY21KTAL
UATY21KYAL
Two independent refrigerant circuit.
(UWA63JAY1–109JAY1, UWA70JATJ–122JATJ, UWA120JY1–270JY1)
The selector switch makes it possible to operate only one refrigerant circuit
while one need repairing.
Cooling Only (50 Hz)
Model
UWA37JAY1
UWA47JAY1
Power supply
Cooling capacity *1
Cooling capacity *2
kW
Btu/h
USRT
kW
Btu/h
USRT
Model
UWA75JAY1
UWA80JAY1
Power supply
Cooling capacity *1
Cooling capacity *2
kW
Btu/h
USRT
kW
Btu/h
USRT
17.5
210,400
53,000
61.6
189,400
55.5
214,400
54,000
62.8
8.98
9.00
9.99
10.01
19.8
20.6
20.6
18.5
19.4
19.4
2. Cooling capacities marked with *2 are based on 29°CDB (84°FDB) 19.0°CWB (66°FWB) indoor temp. and 46°CDB (115°FDB) outdoor temp.
3. Heating capacities are based on 21°CDB for indoor temp. 7°CDB/6°CWB for outdoor temp.
Net capacity (Btu/h)
4. The figures of *2 is reference value.
EER =
5. *3: EER Cooling conditions: 27°CDB (80°FDB) and 19.5°CWB (67°FWB) for indoor temp. 35°CDB (95°FDB) for outdoor temp.
Unit power comsumption (W)
6. *4: EER Heating conditions: 20°CDB for indoor temp. 7°CDB/6°CWB for outdoor temp.
(Compressor + Outdoor fan motor)
UWA55JAY1
UWA63JAY1
3 phase, 380-415 V, 50 Hz
137.2
161.3
468,200
550,400
39.0
45.8
124.8
149.9
425,800
511,500
35.4
42.6
108.4
369,800
30.8
97.4
332,500
27.7
186.0
634,900
52.9
167.4
571,400
47.6
UWA93JAY1
UWA109JAY1
3 phase, 380-415 V, 50 Hz
250.6
272.7
855,100
930,500
71.2
77.5
225.5
250.8
769,400
855,900
64.1
71.3
219.1
747,600
62.3
197.1
672,600
56.0
319.2
1,089,200
90.7
290.5
991,200
82.6
Cooling Only (50 Hz)
Model
UWA120JY1
UWA138JY1
Power supply
Operation range
5 to 52
Cooling °CDB
(Outdoor temp.)
Heating °CWB
-10 to 15.5
Notes: 1. Cooling capacities marked with *1 are based on 27°CDB (80°FDB) 19.5°CWB (67°FWB) indoor temp. and 35°CDB (95°FDB) outdoor temp.
41
Capacity can be controlled in multiple steps from 3 to 7 steps to save
energy.
Equipped with a compact and
powerful semi-hermetically sealed
reciprocating compressor.
Heat Pump (50 Hz/60 Hz)
Cooling capacity *1
(50/60 Hz)
(UWA37JAY1–109JAY1, UWA43JATJ–122JATJ, UWA120JY1–270JY1)
Operative high outdoor temperature.
UWA37JAY1–109JAY1: 5 to 52°C
UWA27JATJ, 37JATJ: 15 to 49°C
UWA43JATJ–122JATJ: 5 to 49°C
UWA120JY1–270JY1: 5 to 49°C
Cooling capacity *1
kW
Btu/h
USRT
351.6
1,201,500
99.9
404.4
1,380,800
115.0
UWA162JY1
UWA192JY1
3 phase, 380-415 V, 50 Hz
474.7
562.8
1,620,600
1,921,500
135.0
160.0
UWA228JY1
UWA270JY1
667.9
2,280,400
189.9
791.0
2,700,800
224.7
Cooling Only (60 Hz)
Model
UWA27JATJ
UWA32JATJ
UWA43JATJ
UWA53JATJ
UWA62JATJ
79.0
269,800
22.4
71.0
242,000
20.1
94.3
320,600
26.7
82.0
280,900
23.4
3 phase, 208-230 V, 60 Hz
125.0
426,600
35.5
111.0
378,900
31.5
162.0
553,500
46.1
145.0
494,000
41.0
185.0
632,100
52.6
171.0
584,100
48.6
UWA70JATJ
UWA80JATJ
UWA90JATJ
UWA108JATJ
UWA122JATJ
253.0
865,000
72.0
219.0
746,400
62.1
3 phase, 208-230 V, 60 Hz
274.0
936,400
78.0
248.0
845,200
70.4
324.0
1,107,000
92.2
285.0
972,200
81.0
370.0
1,262,000
105.0
335.0
1,145,000
95.3
Power supply
Cooling capacity *1
Cooling capacity *2
kW
Btu/h
USRT
kW
Btu/h
USRT
Model
Power supply
Cooling capacity *1
Cooling capacity *2
kW
Btu/h
USRT
kW
Btu/h
USRT
212.0
722,200
60.0
191.0
653,100
54.2
Notes : *1 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7°C (44°F), entering water temp. 12.2°C (54°F) outdoor temp. 35°C (95°FDB).
*2 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7°C (44°F), entering water temp. 12.2°C (54°F) outdoor temp. 46.0°C (115°FDB).
42

advertisement

Key Features

  • Split type
  • SkyAir type
  • VRV type
  • Packaged Air Conditioners type

Related manuals

Frequently Answers and Questions

What are the different types of air conditioners offered by Daikin?
Daikin offers a variety of air conditioning solutions, including split systems, SkyAir systems, VRV systems, and packaged air conditioners. Each type has its own advantages and disadvantages, so it is important to choose the right type of system for your needs.
What is a split system air conditioner?
A split system air conditioner has two main components: an indoor unit and an outdoor unit. The indoor unit is typically mounted on a wall or ceiling, and the outdoor unit is installed outside. Split systems are ideal for cooling and heating individual rooms or small spaces.
What is a SkyAir system?
SkyAir is a type of split system air conditioner that offers advanced features and capabilities, such as energy efficiency, quiet operation, and flexible installation options.
What is a VRV system?
VRV stands for Variable Refrigerant Flow. VRV systems use a single outdoor unit to connect multiple indoor units. This makes VRV systems ideal for cooling and heating larger areas, like offices and commercial buildings.
What are packaged air conditioners?
Packaged air conditioners are self-contained units that combine the indoor and outdoor components in a single housing. They are typically used for cooling and heating larger spaces, such as retail stores, restaurants, and industrial buildings.
Download PDF