VQZ/1000/2000/3000 Series - 3/5 Port Solenoid Valve Metal/Rubber Seal

Add to My manuals
31 Pages

advertisement

VQZ/1000/2000/3000 Series - 3/5 Port Solenoid Valve Metal/Rubber Seal | Manualzz

VQZ Series 3/9/99 4:20 PM Page 29

3/5 Port Solenoid Valve

Metal Seal/Rubber Seal

Base Mounted

VQZ1000/2000/3000

Compact design with large flow capacity

Body Width

Cv

10mm 0.2

15mm

18mm

0.6

0.9

High speed and Long life

Response time

VQZ1000 10ms

Life

VQZ2000 12ms 2 million cycles

VQZ3000 15ms

Dispersion accuracy

±

2ms

Metal seal, single solenoid with light and

surge voltage suppressor

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

DIN rail mounting is available.

Both 3 and 5 port valves can be mounted on the same manifold.

3 port valve

5 port valve

VQ

VQ4

VQZ

Built-in One-touch fittings for easier piping.

lntegral One-touch fittings save on installation time and labor and can be easily removed if necessary.

Clip port plug

VQD

VZS

VFS

VS

VS7

Fitting ass'y

Choice of metal or rubber seal main valve construction

Piping direction can be changed on VQZ100.

Fitting ass'y

It's possible to change from side to top porting and vice versa.

Clip

Optional IP65 rated model is available with DIN connector.

Possible to have all solenoids on same side of manifold

Optional latching coil valve operates the same as a 2 position/ double solenoid valve but uses only one solenoid. This saves space and wiring costs.

Port plug

All solenoids on one side

(Latching solenoid style)

Manual override

1.12-29

VQZ Series 3/11/99 6:04 PM Page 30

Series

VQZ

Base Mounted

Model Selection

VQZ1000

VQZ2000

VQZ3000

VQZ1000

VQZ2000

Cv

Metal/ Rubber

Function

0.2

0.35

0.6

0.9

0.7

1.2

2 Position single

(A)

4

(B)

2

5 1

(R1) (P)

3

2 Position double

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

3 Position closed center

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

3 Position exhaust center

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

3 Position pressure center

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

0.2

0.35

Voltage

Electrical entry

Grommet (G)

Light and surge voltage suppressor

Manual override

(standard)

12V DC

24V DC

(Option)

100V AC

200V AC

110V AC

220V AC

L plug connector (L)

Indicator light and surge voltage suppressor

M plug connector (M)

L plug connector (L)

M plug connector (M)

Non-locking push style

(Flush)

0.6

0.7

(A)

4

5 1

N.C.

(A)

4

5 1

N.O.

DIN connector

(Y)

Except for

VQZ 1000

DIN connector

(YZ)

Except for

VQZ 1000

Locking style

(Slotted)

VQZ3000

0.9

1.2

Base mounted

(With sub-plate)

Cv

Cylinder speed

(mm/s)

Series CJ2

Bore size (mm)

Series CM2 Series CA1

ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100

VQZ1000

Body width 10

VQZ2000

Body width 15

0.35

0.7

150

300

450

600

750

150

300

450

600

750

150

V

V

V V

V V

V V

V V

300

VQZ3000

Body width 18

1.2

450

V

V V

600

V V

750

Cylinder speed marked with “

V

” can be controlled by speed controller. (Pressure: 0.5 MPs, Load rate: 50%)

1.12-30

∗∗

VQZ Series 3/11/99 6:05 PM Page 31

VQZ1000/2000/3000

Base Mounted

Precautions

Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety lnstructions and common precautions.

Warning

Manual Override

Without an electric signal for the solenoid valve the manual override is used for switching the main valve.

Non-locking push style (Flush)

Locking style (Slotted)

Push down on the manual override button with a small screwdriver until it stops.

Release the screwdriver and the manual override will return.

Push down on the manual override button with a small screwdriver until it stops. While down, turn clockwise by 90

° to lock it. Turn it counterclockwise to release it.

Caution

How to Use L and M Plug Connector

Insertion/Removal of connector

M plug connector

Cover

Pin

Insertion:

Push the connector straight onto the pins of the solenoid, making sure the lip of the lever securely

“locks” into the groove of the solenoid cover.

L plug connector

Cover

Groove

Pin

Removal:

Press the lever against the connector housing and pull it outward from the solenoid.

Connector

AXT661-12

Lead wire

0.2 to 0.33mm

2

(Max.O.D. ø1.7mm)

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

Lever

Groove

Hook

Socket

DXT170-71-1

VQ

Refer to p.1.12-59 for part no. of plug connector ass'y.

VQ4

VQZ

VQD

Connection and Electrical Circuit

The VQZ series features non-polar solenoids.

Black(DC)

Blue

Red

100V AC

110V AC

200V AC

220V AC

Red (DC)

Blue

Red

100V AC

110V AC

200V AC

220V AC

VZS

VFS

VS

VS7

Indicator light

∗∗

With light and surge voltage suppressor

Circuit for DC

A(–)

[+]

C(+)

[–]

Light

ZNR

SOL

A

Circuit for AC

Light

SOL

C

Due to the use of non-polar light, the VQZ series has no polarity.

Refer to p.1.12-57 for latching style.

1.12-31

VQZ Series 3/11/99 6:06 PM Page 32

Series

VQZ

Base Mounted

Precautions

Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety lnstructions and common precautions.

Connection of Lead Wire

(Not necessary if ordering the lead wire pre-connected model.)

Crimping connection of lead wire and socket

Strip 3.2 to 3.7mm of the lead wire ends, insert each stripped wire into a socket and crimp contact it using special crimping tool. Be careful that the outer insulation of the lead wires does not interfere with the socket contact part.

Crimping area

Core wire contact area

Core wire

0.2 to 0.33mm

2

Max. cover diameter

: ø1.7mm

Socket

Lead wire

Insulation

Hook

Tool for crimping: Model No. DXT170-75-1

Connection/Disconnection of socket with lead wire

Connection

Insert lead wire and crimped socket into square holes (indicated as A, B,

COM) of connector. Press the socket in fully until the hook of the socket locks into the groove of the connector housing. Confirm the locked position by lightly pulling on the lead wire.

Disconnection

To remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screw driver (or similar). If the socket is to be re-used, reposition the hook again.

Connector

How to Wire the DIN Connector

Conforming to ISO#: DIN 43650 C (8mm between pins)

Cut the power and air supply before mounting/removing the connector.

q

Loosen the top screw and remove the connector housing from the

terminal spades on the solenoid.

w

Remove the housing screw and insert a screwdriver into the slot area

on the underside of the DIN cap and carefully separate block and

housing.

e

Loosen the terminal screws of the block and insert stripped lead wires in

accordance with the wiring diagram. Secure each wire by retightening

the terminal screw.

r

Tighten the housing grommet nut to secure the cable wire.

Change of electrical entry (orientation)

Once the housing is separated from the terminal block, it can be rotated in any direction to change the orientation of the electrical entry.

lead wire connections.

Precaution

Pull connector out vertically, never at an angle.

Applicable cable

Cord O.D.: ø3.5 to ø7

(Reference) 0.5mm

2

2-core and 3-core wires equivalent to JISC3306.

Fix screw Ground nut

Washer

Grommet

(Rubber)

(Voltage symbol)

Refer to below table.

Socket

Lead wire

Housing

(Position for light mounting)

Terminal block

Shaved part

Hook

Terminal thread

(3 positon)

Part No. of DIN Connector (Based on DIN)

Without light

With light

Rated voltage

24V DC

12V DC

100V AC

200V AC

110V AC

220V AC

Voltage symbol

24V

12V

100V

200V

110V

220V

AXT100-20-1

Part No.

AXT100-20-2-05

AXT100-20-2-06

AXT100-20-2-01

AXT100-20-2-02

AXT100-20-2-03

AXT100-20-2-04

Circuit with light

AC circuit DC circuit

1

2

1

2

NL

R

NL: Neon light

R: Resister

LED

R

LED: Emitting diode

R: Resister

∗∗

1.12-32

VQZ Series 3/11/99 6:06 PM Page 33

VQZ1000/2000/3000

Base Mounted

Caution

Mounting 3 Port Valves on 5 Port Manifolds

1

2

3

0

1

1

2

3

0

(VQZ 85 , N.C./ VQZ 95 , N.O.)

Valve Mounting

When a 3 port valve is mounted on a 5 port manifold, the

“A” port is the working port. The “B” port can either be plugged or unplugged.

3 port valve 5 port valve

After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.

Model Suitable tightening torque

VQZ1000

VQZ2000

VQZ3000

0.18 to 0.25Nm

0.25 to 0.35Nm

0.5 to 0.7Nm

SY

When port plug is used on B port, indicate “CM” in manifold part no. and port size, and supecify the port plug location in manifold specification form.

SYJ

SX

Port plug

Changing the One-touch Fittings

The built-in fittings on the manifold can be changed easily. Simply remove the corresponding valve and take out the fitting clip underneath. Then remove the affected fitting and replace with a new one. Finally, replace the fitting clip and remount the valve.

Screw

VK

VZ

VF

VFR

VP7

VP4

Clip

Precaution

When pulling the fitting ass'y away from the manifold base, remove the clip, then connect a tube or plug (KQP– ll

) with the One-touch fitting and pull out it holding the tube or plug. Do not hold the release bushing to avoid damage.

DIN Rail Removal/Mounting

One-touch Ass'y

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

To remove manifold from DIN rail:

1) Loosen the clamp screw on the

“A” side of both ends of the

manifold.

2) Lift the “A” side of the

manifold off the DIN rail

and side it in the direction

of the “B” side.

Clamp screw

Mounting manifold to DIN rail:

1) Catch the hook of the DIN rail

bracket on the “B” side on the

DIN rail.

2) Push side “A” onto the DIN rail

and tighten the clamp screw.

(Tighening torque of 0.3 to 0.4

Nm{3 to 4kgf/cm})

A

B

∗∗

1.12-33

VQZ Series 3/11/99 6:07 PM Page 34

Base Mounted

Plug Lead Unit

5 Port Solenoid Valve

VQZ1000/2000/3000

Single Unit

How to Order Valve

VQZ 1 1 5 1

Series

1

2

3

VQZ1000 Body width 10mm

VQZ2000 Body width 15mm

VQZ3000 Body width 18mm

Configuration

2 position single

(A)

4

(B)

2

1

5

(R1)

1

(P)

3

(R2)

2 position double

(A)

4

(B)

2

(A)

4

(B)

2

2

5

(R1)

1

(P)

3

(R2)

Metal

5

(R1)

1

(P)

3

(R2)

Rubber

3 position closed center

(A)

4

(B)

2

3

5

(R1)

1

(P)

3

(R2)

3 position exhaust center

(A)

4

(B)

2

4

5

(R1)

1

(P)

3

(R2)

Note)

5

3 position pressure center

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

Note) Except VQZ1000 and

metal seal style.

5 M 01

Port size [4(A), 2(B) port]

Symbol

01

02

03

Port size

Without sub-plate

Rc(PT)1/8

Rc(PT)1/4

Rc(PT)3/8

VQZ1000 VQZ2000 VQZ3000 v v

— v v v

— v

— v v

Manual override

—:

Non-locking push style

(Flush)

B: Locking style

(Slotted)

Electrical entry

G: Grommet

(DC specification)

L: L plug connector with lead wire

With light and surge voltage suppressor

LO: L plug terminal without connector

With light and surge voltage suppressor

M: M plug connector with lead wire

With light and surge voltage suppressor

MO: M plug terminal without connector

With light and surge voltage suppressor

Body

5

Base mounted

Y: DIN

(1) connector

YO: DIN

(1) terminal without connector

YZ: DIN

(1) connector

YOS: DIN

(1) terminal without connector

With light and surge voltage suppressor

With surge voltage suppressor

Seal

0

1

Metal seal

Rubber seal

Note 1) DIN is applicable to VQZ2000 and 3000.

Note 2) Standard lead wire length: 300mm

Function

Symbol

K

(1)

Y

(1)

R

(3)

Specification

Standard

DC

(1.0W) v

AC v

(3)

High pressure

(Metal seal)

Low wattage

(1.0W) v

(0.5W) v v

External pilot v

Note 1) Option

Note 2) Refer to p.1.12-58 for details about

external pilot specification except VQZ1000.

Note 3) Refer to p.1.12-35 for power

consumption of AC type.

Note 4) When specifying more than one option,

indicate them alphabetically.

1

Coil voltage

100V AC (50/60Hz)

2

3

4

200V AC (50/60Hz)

110V AC (50/60Hz)

220V AC (50/60Hz)

5

6

9

24V DC

12V DC

Others

grommet style and/or special voltage,

consult SMC.

Note) Refer to p.1.12-59 for

sub-plate part no.

1.12-34

∗∗

VQZ Series 3/11/99 6:08 PM Page 35

VQZ1000/2000/3000

Base Mounted

Standard Specifications

Model

Seal

Fluid

Max. operationg pressure

Min.

operating pressure

2 position

Single

Double

3 position

Ambient and fluid temperature

Max.

operating frequency

2 position

3 position

Single

Double

Pilot valve EXH

Lubrication

Manual override

Shock/Vibration resistance

(2)

Enclosure

Coil rated voltage

Allowable voltage

Coil insurance

Power consumption

(Current value)

24V DC

12V DC

100V AC

110V AC

200V AC

220V AC

Metal seal

Air, lnert gas

Rubber seal

Air, lnert gas

0.7MPa (High pressure type: 1.0MPa)

0.1MPa only for VQZ3000, 3 position

0.15MPa

–10 to 50

°

C

20Hz

10Hz

(1)

0.15MPa

0.1MPa

0.2MPa

–10 to 50

°

C

(1)

5Hz

3Hz

Individual EXH

Not required

Non-locking push Locking slotted styles

150/30 m/s

2

Dust-proof

12V, 24V DC and 100V, 110V, 200V, 220V AC

±

10% of rated voltage

Class B

1W DC (42mA), 1.5W DC (63mA), 0.5W DC (21mA)

1W DC (83mA), 1.5W DC (125mA), 0.5W DC (42mA)

Inrush 1.2VA (12mA), Holding 1.2VA (12mA)

Inrush 1.3VA (11.7mA), Holding 1.3VA (11.7mA)

Inrush 2.4VA (12mA), Holding 2.4VA (12mA)

Inrush 2.6VA (11.7mA), Holding 2.6VA (11.7mA)

Note 1) Use dry air to prevent condensation when operating at low temperatures.

test was performed on the axis and right angle direction of the main valve and armature, for both energized and de-energized states. (Value in the initial stage.)

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

was performed at both energize and de-energized states to the axis and right angle direction of the main valve and armature. (Value in the initial stage.)

VQ

Weight (g)

(3)

37

VQ4

VQZ

Series

VQZ1000

Configuration

2 position

3 position

Single

Double

Closed center

Exhaust center

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Model

VQZ1150

VQZ1151

VQZ1250

VQZ1251

VQZ1350

VQZ1351

VQZ1450

VQZ1451

(1)

Effective area (mm

2

)(Cv)

3.6 (0.2)

6.3 (0.35)

3.6 (0.2)

6.3 (0.35)

2.2 (0.12)

3.6 (0.2)

3.6 (0.2)

6.3 (0.35)

Response time (ms)

(2)

Standard: 1W

High pressure: 1.5W

High pressure: 1W

Low wattage and AC

12 or less

12 or less

15 or less

15 or less

10 or less

10 or less

20 or less

25 or less

20 or less

25 or less

13 or less

13 or less

26 or less

33 or less

26 or less

33 or less

VQZ2000

VQZ3000

2 position

3 position

2 position

3 position

Pressure center

Single

Double

Closed center

Exhaust center

Pressure center

Single

Double

Closed center

Exhaust center

Pressure center

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

Metal seal

Rubber seal

VQZ1551

VQZ2150

VQZ2151

VQZ2250

VQZ2251

VQZ2350

VQZ2351

VQZ2450

VQZ2451

VQZ2550

VQZ2551

VQZ3150

VQZ3151

VQZ3250

VQZ3251

VQZ3350

VQZ3351

VQZ3450

VQZ3451

VQZ3550

VQZ3551

3.6 (0.2)

10.8 (0.6)

12.6 (0.7)

10.8 (0.6)

12.6 (0.7)

7.2 (0.4)

9.0 (0.5)

10.0 (0.55)

12.6 (0.7)

7.2 (0.4)

9.0 (0.5)

16.2 (0.9)

21.6 (1.2)

16.2 (0.9)

21.6 (1.2)

14.4 (0.8)

16.2 (0.9)

15.3 (0.85)

21.6 (1.2)

14.4 (0.8)

16.2 (0.9)

25 or less

14 or less

15 or less

10 or less

12 or less

23 or less

25 or less

23 or less

25 or less

23 or less

25 or less

17 or less

25 or less

10 or less

15 or less

25 or less

30 or less

25 or less

30 or less

25 or less

30 or less

33 or less

18 or less

20 or less

13 or less

15 or less

30 or less

33 or less

30 or less

33 or less

30 or less

33 or less

22 or less

33 or less

13 or less

20 or less

33 or less

39 or less

33 or less

39 or less

33 or less

39 or less

Note 1) Value for sub-plate and maximum diameter

Note 2) As per JISB8375-1981 (Supply pressure; 0.5MPa; with indicator light and surge voltage suppressor; clean air)

The response time is subject to the pressure and the air quality. The values at the time of ON are given for double styles.

Note 3) Weight without sub-plate

56

60

84

94

119

1.12-35

VQD

VZS

VFS

VS

VS7

∗∗

VQZ Series 3/11/99 6:09 PM Page 36

VQZ1000/2000/3000

Base Mounted

Construction: VQZ1000/2000/3000

Metal seal Rubber seal

4

3 2 1

4

3 2

1

4 3

2 1

2 position single

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

4

3

2 1

2 position single

(A) (B)

4 2

5

(R1)

1

(P)

3

(R2)

4

3

2 1

2 position double

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

4

3 2 1

2 position double

(A) (B)

4 2

5

(R1)

1

(P)

3

(R2)

3 position closed center

(A)

4

(B)

2

3 position exhaust center

(A)

4

(B)

2

(1)

3 position pressure center

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

5

(R1)

1

(P)

3

(R2)

5

(R1)

1

(P)

3

(R2)

Note 1) Except for VQZ1000

and metal seal

3 position closed center

(A)

4

(B)

2

3 position exhaust center

(A)

4

(B)

2

3 position pressure center

(A)

4

(B)

2

5

(R1)

1

(P)

3

(R2)

5

(R1)

1

(P)

3

(R2)

5

(R1)

1

(P)

3

(R2)

Component Parts

No.

q

Description

Body w e r

Spool/Sleeve

Spool valve

Piston

Pilot valve

Meterial

Alminum die cast

Stainless steel

Aluminum/NBR

Resin

Note

Metal seal

Rubber seal

1.12-36

VQZ Series 3/11/99 6:10 PM Page 37

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ1000

2 position single

0

Grommet(G): VQZ115 (R)–

l

G

l

–01

300

(Lead wire length)

68.5

47.5

R3

7.2

4 2

18

7.2

2-ø3.4Mounting holes

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

5 1

36

42

3

3

69.5 (Metal seal)

67 (Rubber seal)

(47.5)

1.1

M5 X 0.8 External pilot port

(Only external pilot style(R))

PE port

R1 R2

P

13.4

13.4

5-Rc(PT)1/8

(P, A, B, R

1

, R

2

port)

SMC

A, B port

M5 X 0.8

(Not applicable to standard model.)

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

L plug connector (L): VQZ115 (R)–

1

l

L

l

–01

300

(Lead wire length)

Indicator light

82 (Metal seal)<83>

80 (Rubber seal)<81>

60<61>

0

M plug connector (M): VQZ115 (R)–

l

M

l

–01

Cover diameter ø1.5

Cross section 0.23mm

2

76 (Metal seal)<77>

73.5 (Rubber seal)<74.5>

54 <55>

Indicator light

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

∗∗

R1

81<82>

P

R2

Cover diameter ø1.5

Cross section 0.23mm

2

R1

75<76>

P

R2

< >: AC < >: AC

1.12-37

VQZ Series 3/11/99 6:10 PM Page 38

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ1000

2 position double

0

Grommet(G): VQZ125 (R)–

l

G

l

–01

300

(Lead wire length)

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

47.5

7.2

R3

4

95

2

18

7.2

5 1

36

42

3

3

2- ø3.4Mounting holes

M5 X 0.8 External pilot port

(Only external pilot style(R))

1.1

(47.5)

2-PE port

R1 R2

P

13.4

13.4

5-Rc(PT)1/8

(P, A, B, R

1

, R

2

port)

A, B port

M5 X 0.8

(Not applicable to standard model.)

∗∗

L plug connector (L): VQZ125 (R)–

l

L

l

–01

0

M plug connector (M): VQZ125 (R)–

l

M

l

–01

Indicator light

300

(Lead wire length)

60<61>

120.5<122.5>

R1

P

R2

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

108<110>

54<55>

R1

P

R2

Cover diameter ø1.5

Cross section 0.23mm

2

< >: AC < >: AC

1.12-38

VQZ Series 3/11/99 6:11 PM Page 39

VQZ1000/2000/3000

Base Mounted

VQZ1000

3 position closed center/exhaust center/pressure center

3

4

0

Grommet(G): VQZ1 5 (R)–

l

G

l

–01

5

300

(Lead wire length)

2- ø3.4Mounting holes

M5 X 0.8 External pilot port

(Only external pilot style(R))

3

4

0

L plug connector (L): VQZ1 5 (R)–

l

L

l

–01

5

Indicator light

300

(Lead wire length)

1.1

Cover diameter ø1.6

Cross section 0.34mm

2 Manual override

2-PE port

129<131>

(47.5)

R1 R2

P

13.4

13.4

5-Rc(PT)1/8

(P, A, B, R

1

, R

2

port)

Cover diameter ø1.5

Cross section 0.23mm

2

117<119>

54<55>

A, B port

M5 X 0.8

(Not applicable to standard model.)

3

4

5

0

M plug connector (M): VQZ1 5 (R)–

l

M

l

–01

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

Indicator light

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

60<61>

R3

47.5

7.2

4

103.5

2

18

7.2

5 1

36

42

3

3

∗∗

Cover diameter ø1.5

Cross section 0.23mm

2

R1

P

R2 R1

P

R2

< >: AC < >: AC

1.12-39

VQZ Series 3/11/99 6:11 PM Page 40

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ2000

2 position single

0

Grommet(G): VQZ215 (R)–

l

G

l

01

02

300

(Lead wire length)

R4

54.5

84.5

9

A 4

9

24

B 2

2-ø4.5Mounting holes

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

5 R1 1 P

48

56

3 R2

4

(54.5)

A, B port

2.1

M5 X 0.8 External pilot port

(Only external pilot style(R))

PE port

18 18

28

5-Rc(PT)1/8,1/4

(P, A, B, R

1

, R

2

port)

2.1

SMC

M5 X 0.8

(Not applicable to standard.)

0

L plug connector (L): VQZ215 (R)–

l

L

l

01

02

300

(Lead wire length)

Indicator light

97.5<98.5>

67.5<68.5>

DIN connector (Y): VQZ215 (R)–

1

l

Y

l

01

02

Pg.7

Applicable cord O.D.

ø3.5 to ø7

MAX.10

101.5

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

< >: AC

0

M plug connector (M): VQZ215 (R)–

l

M

l

01

02

Cover diameter ø1.5

Cross section 0.23mm

2

Indicator light

91.5<92.5>

61.5<62.5>

73.5

103.5

∗∗

< >: AC

1.12-40

VQZ Series 3/11/99 6:11 PM Page 41

VQZ1000/2000/3000

Base Mounted

VQZ2000

2 position double

0

Grommet(G): VQZ225 (R)–

l

G

l

01

02

300

(Lead wire length)

A, B port

2.1

54.5

R4

A 4

109

9 9

24

B 2

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

5 R1 1 P

48

56

3 R2

4

(54.5)

2-PE port

M5 X 0.8 External pilot port

(Only external pilot style(R))

2- ø4.5Mounting holes

18 18

28

5-Rc(PT)1/8,1/4

(P, A, B, R

1

, R

2

port)

2.1

SMC

M5 X 0.8

(Not applicable to standard.)

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

0

L plug connector (L): VQZ225 (R)–

l

L

l

01

02

Indicator light

300

(Lead wire length)

67.5<68.5>

135<137>

DIN connector (Y): VQZ225 (R)–

l

Y

l

01

02

Pg.7

MAX.10

142.5

71.5

Indicator light

Applicable cord O.D.

ø3.5 to ø7

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

Cover diameter ø1.5

Cross section 0.23mm

2

< >: AC

0

M plug connector (M): VQZ225 (R)–

l

M

l

01

02

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

122.5<124.5>

61.5<62.5>

73.5

147

< >: AC

1.12-41

VQZ Series 3/11/99 6:12 PM Page 42

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ2000

3 position closed center/exhaust center/pressure center

3

4

0

Grommet(G): VQZ2 5 (R)–

l

G

l

01

02

5

300

(Lead wire length)

54.5

R4

A 4

122

9 9

B 2

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

(54.5)

5 R1 1 P

48

56

3 R2

4

2- ø4.5Mounting holes

A, B port

2.1

2-PE port

M5 X 0.8 External pilot port

(Only external pilot style(R))

18 18

28

5-Rc(PT)1/8,1/4

(P, A, B, R

1

, R

2

port)

3

4

5

0

L plug connector (L): VQZ2 5 (R)–

l

L

l

01

02

Indicator light

300

(Lead wire length)

67.5<68.5>

148<150>

3

2.1

SMC

M5 X 0.8

(Not applicable to standard.)

DIN connector (Y): VQZ2 5 (R)–

5

0

1

l

Y

l

01

02

Pg.7

MAX.10

71.5

155.5

Applicable cord O.D.

ø3.5 to ø7

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

3

4

0

M plug connector (M): VQZ2 5 (R)–

l

M

l

01

02

5

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

61.5<62.5>

135.5<137.5>

< >: AC

73.5

160

∗∗

< >: AC

1.12-42

VQZ Series 3/11/99 6:12 PM Page 43

VQZ1000/2000/3000

Base Mounted

VQZ3000

2 position single

0

Grommet(G): VQZ315 (R)–

l

G

l

02

03

300

(Lead wire length)

R5

95

58

10.5

(Rc(PT)3/8)

9

(Rc(PT)1/4)

A 4 B

28

10.5

(Rc(PT)3/8)

9

(Rc(PT)1/4)

2

2- ø4.5Mounting holes

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

(58)

5 R1 1 P

56

66

3 R2

5

SMC

A, B port

M5 X 0.8 External pilot port

(Only external pilot style(R))

PE port Rc(PT)1/4,3/8

P port

18 18

(Rc(PT)1/4) (Rc(PT)1/4)

21 21

(Rc(PT)3/8) (Rc(PT)3/8)

33

2-Rc(PT)1/4, 3/8

R

1

, R

2

port

0

L plug connector (L): VQZ315 (R)–

l

L

l

02

03

Indicator light

300

(Lead wire length)

107.5<108.5>

71<72>

SMC

M5 X 0.8

(Not applicable to standard.)

DIN connector (Y): VQZ315 (R)–

l

Y

l

02

03

Pg.7

MAX.10

Applicable cord O.D.

ø3.5 to ø7

111.5

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

0

M plug connector (M): VQZ315 (R)–

l

M

l

02

03

Cover diameter ø1.5

Cross section 0.23mm

2

101.5<102.5>

65<66>

Indicator light

< >: AC

77

114

< >: AC

1.12-43

VQZ Series 3/11/99 6:12 PM Page 44

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ3000

2 position double

Grommet(G): VQZ325 (R)–

1

l

G

l

02

03

300

(Lead wire length)

58

10.5(Rc(PT)3/8)

9(Rc(PT)1/4)

R5

116.5

28

10.5(Rc(PT)3/8)

9(Rc(PT)1/4)

A 4 B 2

2- ø4.5Mounting holes

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

(58)

5 R1 1 P

56

66

3 R2

5

A, B port

M5 X 0.8 External pilot port

(Only external pilot style(R))

2-PE port

Rc(PT)1/4, 3/8

P port

18 18

(Rc(PT)1/4) (Rc(PT)1/4)

21 21

(Rc(PT)3/8) (Rc(PT)3/8)

33

2-Rc(PT)1/4, 3/8

R

1

, R

2

port

SMC

M5 X 0.8

(Not applicable to standard.)

DIN connector (Y): VQZ325 (R)–

l

Y

l

02

03

0

L plug connector (L): VQZ325 (R)–

l

L

l

02

03

Indicator light

300

(Lead wire length)

71<72>

142<144>

Cover diameter ø1.5

Cross section 0.23mm

2

0

M plug connector (M): VQZ325 (R)–

l

M

l

02

03

Cover diameter ø1.5

Cross section 0.23mm

2

130<132>

65<66>

Indicator light

< >: AC

Pg.7

MAX.10

Applicable cord O.D.

ø3.5 to ø7

75

77

150

Indicator light

154.5

< >: AC

1.12-44

VQZ Series 3/11/99 6:13 PM Page 45

VQZ1000/2000/3000

Base Mounted

VQZ3000

3 position closed center/exhaust center/pressure center

3

4

0

Grommet(G): VQZ3 5 (R)–

l

G

l

02

5

300

03

(Lead wire length)

130

58 28

10.5(Rc(PT)3/8) 10.5(Rc(PT)3/8)

9(Rc(PT)1/4)

R5

9(Rc(PT)1/4)

A 4 B 2

2- ø4.5Mounting holes

A, B port

Cover diameter ø1.6

Cross section 0.34mm

2

Manual override

(58)

5 R1 1 P 3 R2

56

66

5

M5 X 0.8 External pilot port

(Only external pilot style(R))

2-PE port

18 18

(Rc(PT)1/4) (Rc(PT)1/4)

21 21

(Rc(PT)3/8) (Rc(PT)3/8)

33

2-Rc(PT)1/4, 3/8

R

1

, R

2

port

Rc(PT)1/4, 3/8

P port

SMC

M5 X 0.8

(Not applicable to standard.)

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

3

4

0

L plug connector (L): VQZ3 5 (R)–

l

L

l

02

03

5

Indicator light

300

(Lead wire length)

71<72>

155.5<157.5>

Cover diameter ø1.5

Cross section 0.23mm

2

3

4

0

DIN connector (Y): VQZ3 5 (R)–

l

Y

l

02

03

5

Pg.7

MAX.10

Applicable cord O.D.

ø3.5 to ø7

75

163.5

Indicator light

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

3

4

0

M plug connector (M): VQZ3 5 (R)–

l

M

l

02

03

5

Cover diameter ø1.5

Cross section 0.23mm

2

143.5<145.5>

65<66>

Indicator light

< >: AC

77

168

∗∗

< >: AC

1.12-45

VQZ Series 2/18/99 3:48 PM Page 46

Base Mounted

Plug Lead Unit

5 Port Solenoid Valve

VQZ1000/2000/3000

Manifold

Connector Kit

How to Order Manifold

VV5QZ 1 5 08 C6 C

Series

1

2

3

VQZ1000

VQZ2000

VQZ3000

5

Manifold

Base mounted

Stations

02

2 stations

20

20 stations

Port size {4(A), 2(B) port}

Symbol

C3

C4

C6

C8

C10

M5

01

02

CM

(1)

Port size

One-touch fitting for ø3.2

One-touch fitting for ø4

One-touch fitting for ø6

One-touch fitting for ø8

One-touch fitting for ø10

M5 thread

Rc(PT)1/8

Rc(PT)1/4

Mixture of port sizes

VQZ1000 VQZ2000 VQZ3000 v v v

– v v v

– v v v v

– v

– v

– v

– v v

Kit

C

Note 1) When ordering port mixture and/or with port plug, suffix it in manifold specifications.

Port mixture and port plug are avaiable only for One-touch type.

Note 2) Refer to p.1.12-58 for inch size and One-touch fitting.

N

Connector

Options

None

D

DO

(1)

N

(2)

R

DIN rail mounting (DIN rail standard length)

DIN rail mounting (Without DIN rail )

With name plate

External pilot

Note 1)Order DIN rail separately.

Refer to p.1.12-52 for DIN raile model no.

Note 2)Applicable to VQZ2000 and 3000.

How to Order Valve

VQZ 1 1 5 1

Series

1

2

3

VQZ1000 Body width 10mm

VQZ2000 Body width 15mm

VQZ3000 Body width 18mm

0

1

Seal

Metal seal

Rubber seal

Configuration

8

9

1

2

3

4

5

(1)

2 position single

2 position double

3 position closed center

3 position exhaust center

3 position pressure center

3 port for mixture mounting N.C.

3 port for mixture mounting N.O.

Note 1) Except VQZ1000 and

metal seal type.

5

Body

Base mounted

1.12-46

Function

Symbol

K

(1)

Specification

Standard

High pressure

DC AC

(1.0W) v v

(3)

(1.0W) v

Y

Low wattage

(0.5W) v

R

(2)

External pilot v

Note 1) Option

Note 2) Refer to p.1.12-58 for details about

external pilot specification

Note 3) Refer to p.1.12-35 for power

consumption of AC type.

Note 4) When specifying more than one option,

indicate them alphabetically.

5 M

Manual override

B

Non-locking push style (Flush)

Locking style (Slotted)

Electrical entry

Symbol

G

L

LO

M

Electrical entry

Light and

surge voltage supressor

Without

Grommet (DC specification)

L plug connector with lead wire

L plug terminal w/o connector

M plug connector with lead wire

With

MO

Y

(1)

YO

(1)

YZ

(1)

YOS

(1)

M plug terminal w/o connector

DIN connector

DIN terminal without connector

DIN connector

Without

With

DIN terminal without connector

With

(w/o light)

Note 1) Applicable to VQZ2000 and 3000.

Note 2) Standerd lead wire length: 300mm

Coil voltage

1

2

3

4

100V AC (50/60Hz)

200V AC (50/60Hz)

110V AC (50/60Hz)

220V AC (50/60Hz)

5

24V DC

6

9

12V DC

Others

When requiring AC specification of grommet style and/or special voltage, consult SMC.

∗∗

VQZ Series 3/11/99 6:13 PM Page 47

VQZ1000/2000/3000

Base Mounted

Manifold Specifications

Series Base model

VQZ1000 VV5QZ15–

lll

Piping specifications

Piping

Port size

1(P), 3/5(R) 4(A), 2(B)

In-line

Rc(PT)

1/8

C3(ø3.2)

C4(ø4)

C6(ø6)

M5(M5 thread)

Applicable

valve

Applicable

stations

(1)

Manifold base weight

(g) l l

2 to 20 stations

2 stations: 105

Addition per/ station: 27

VQZ2000 VV5QZ25–

lll

In-line

Rc(PT)

1/4

C4(ø4)

C6(ø6)

C8(ø8)

Rc(PT)1/8

VQZ2 50

l

2 to 20 stations

2 stations: 193

Addition per/ station: 54

SY

SYJ

SX

VQZ3000 VV5QZ35–

lll

In-line

1(P)port

Rc(PT)3/8

3·5(R)port

Rc(PT)1/4

C6(ø6)

C8(ø8)

C10(ø10)

Rc(PT)1/4

VQZ3 50

l

2 to 20 stations

2 stations: 398

Addition per/ station: 102

VK

VZ

Note 1) Threaded port.

VF

How to Order Valve Manifold Assembly (Example)

VFR

VP7

VP4

VQZ2150-5L

VQZ2250-5L

VQZ2350-5L

D side

1

2

3

4

5

U side

VV5QZ25–05C6C……1 set (C kit 5 stations manifold base)

VVQZ2000–10A-5…1 set (Blank plate assembly)

VQZ2150–5L ………1 set (Valve P/N – single solenoid)

VQZ2250–5L ………2 set (Valve P/N – double solenoid)

VQZ2350–5L ………1 set (Valve P/N – 3 position)

Write sequentially from the 1st station on the D side.

Add valve suffix and option numbers to the manifold base number.

When part numbers written collectively are complicated, specify by using a manifold specification form.

VQ

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

VVQZ2000-10A-5

C6: One-touch fitting for ø6

∗∗

1.12-47

VQZ Series 3/11/99 6:13 PM Page 48

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ1000

Grommet (G)

4- ø4.5 Mounting holes

DIN rail clamp screw

Manual override

(35)

(5.5)

(4.5)

U side

n

5

4

3

2

1

Stations

D side

2n-M5

36

28.5

14

(11)

(7.5)

6.5

2n-C3, C4, C6

C3: One-touch fitting for ø3.2

C4: One-touch fitting for ø4

C6: One-touch fitting for ø6

A 4 B 2

A 4 B 2

300

(Lead wire length)

8 8

44 30.5

67 (Single, rubber)

69.5 (Single, metal)

95 (Double)

103.5 (3 Position)

Cover diameter ø1.6

Cross section 0.34mm

2

14

6.5

M5

R1

5

1 P

3 R2

R1

5

X

1 P

3

R2

PE port

2-Rc(PT)1/8

P(SUP) port

L plug connector (L)

15.5

15.5

(30.5)

54

4-Rc(PT)1/8

R1, R2(EXH) port

2-M5 X 0.8 External pilot port

6.5

15 16.5

16.5

57

33

External pilot port

7

The broken line indicate DIN rail mounted style [-D].

M plug connector (M)

300

(Lead wire length)

Indicator light

129 (3 Position)<131>

120.5 (Double)<122.5>

82 (Single, metal)<83>

80 (Single, rubber)<81>

57<58>

Indicator light

117 (3 Position)<119>

108 (Double)<110>

76 (Single, metal)<77>

73.5 (Single, rubber)<74.5>

50.5<51.5>

Cover diameter ø1.5

Cross section 0.23mm

2

Cover diameter ø1.5

Cross section 0.23mm

2

R1 5

1 P

3 R2 R1 5

1 P

3 R2

< >: AC < >: AC

Dimensions

L n

2 3

L1

L2

30.5

38.5

41

49

L3

62.5

75

L4

73 85.5

1.12-48

Equation L1=10.5n+9.5 L2=10.5n+17.5

4

51.5

59.5

87.5

98

5

62

70

100

110.5

6

72.5

80.5

100

110.5

7

83

91

112.5

123

8

93.5

101.5

125

135.5

9

104

112

137.5

148

10

114.5

122.5

150

160.5

11

125

133

162.5

173

12

135.5

143.5

175

185.5

13

146

154

175

185.5

14

156.5

164.5

187.5

198

15

167

175

200

210.5

16

177.5

185.5

212.5

223 n: Station (Max. 20 stations)

17

188

196

225

235.5

18

198.5

206.5

237.5

248

19

209

217

237.5

248

20

219.5

227.5

250

260.5

∗∗

VQZ Series 3/11/99 6:14 PM Page 49

VQZ1000/2000/3000

Base Mounted

VQZ2000

Grommet (G)

4- ø4.5 Mounting holes

DIN rail clamp screw

Manual override

300

(Lead wire length)

10 10

53 38

84.5 (Singles)

109 (Double)

122 (3 Position)

Cover diameter ø1.6

Cross section 0.34mm

2

PE port

2-Rc(PT)1/4

P(SUP) port

(35)

(5.5)

(2)

R1 5

1 P 3 R2

20

67

20

(38)

L plug connector (L)

300

(Lead wire length)

Indicator light

148 (3 Position)<150>

135 (Double)<137>

97.5 (Single)<98.5>

65.5<66.5>

Cover diameter ø1.5

Cross section 0.23mm

2

R1 5

1 P

3 R2

41

33

15

(12)

(7.5)

7.7

2n-C4, C6, C8

C4: One-touch fitting for ø4

C6: One-touch fitting for ø6

C8: One-touch fitting for ø8

4-Rc(PT)1/4

R1, R2(EXH) port

11

U side

n

5

4

3

2

1

Stations

D side

< >: AC

2n-Rc(PT)1/8

15

7.7

Rc(PT)1/8

R1 5

X

1 P 3 R2

2-M5 X 0.8

External pilot port

Pg.7

Applicable cord O.D.

ø3.5 to ø7

16 20

20 37.4

66.5

External pilot port

11

DIN connector (Y)

MAX.10

155.5 (3 Position)

142.5 (Double)

101.5 (Single)

69.5

Indicator light

VQ

The broken line indicate

DIN rail mounted style [-D].

VQ4

VQZ

VQD

VZS

VFS

VS

VS7

R1 5

1 P

3 R2

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

M plug connector (M)

135.5 (3 Position)<137.5>

122.5 (Double)<124.5>

91.5 (Single)<92.5>

59.5<60.5>

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

72

∗∗

R1 5

1 P

3 R2

< >: AC

Dimensions

n

L

2 3

L1

42 58

L2

L3

L4

52

75

85.5

68

87.5

98

Equation L1=16n+10 L2=16n+20

4

74

84

112.5

123

5

90

100

125

135.5

6

106

116

137.5

148

7

122

132

162.5

173

8

138

148

175

185.5

9

154

164

187.5

198

10

170

180

200

210.5

11

186

196

225

235.5

12

202

212

237.5

248

13

218

228

250

260.5

14

234

244

275

285.5

15

250

260

287.5

298

16

266

276

300

310.5

n: Station (Max. 20 stations)

17

282

292

312.5

323

18

298

308

337.5

348

19

314

324

350

360.5

20

330

340

362.5

373

1.12-49

VQZ Series 3/11/99 6:14 PM Page 50

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ3000

Grommet (G)

4- ø4.5 Mounting holes

DIN rail clamp screw

(35)

(5.5)

300

(Lead wire length)

Cover diameter ø1.6

Cross section 0.34mm

2

PE port

Manual override

U side

n

5

4

3

2

1

Stations

D side

11.5

11.5

57.5

42

95 (Singles)

116.5 (Double)

130 (3 Position)

2-M5 X 0.8 External pilot port

(Only external pilot port (R))

2n-Rc(PT)1/4

49

41

19.5

(12)

(7.5)

9.4

19.5

Rc(PT)1/4

9.4

R1 5

1 P

3

R2

2n-C6, C8, C10

C6: One-touch fitting for ø6

C8: One-touch fitting for ø8

C10: One-touch fitting for ø10

2-Rc(PT)3/8

P(SUP) port

21 21

26

(42)

73

4-Rc(PT)1/4

R1, R2(EXH) port

11

DIN connector (Y)

The broken line indicate DIN rail mounted style[-D].

L plug connector (L)

300

(Lead wire length)

Indicator light

155.5 (3 Position)<157.5>

142 (Double)<144>

107.5 (Single)<108.5>

70.5<71.5>

MAX.10

Pg.7

Applicable cord O.D.

ø3.5 to ø7

163.5 (3 Position)

150 (Double)

111.5 (Single)

74.5

Indicator light

Cover diameter ø1.5

Cross section 0.23mm

2

R1 5

1 P

3

R2

< >: AC

R1 5

1 P

3 R2

M plug connector (M)

Indicator light

143.5 (3 Position)<145.5>

130 (Double)<132>

101.5 (Single)<102.5>

64.5<65.5>

Cover diameter ø1.5

Cross section 0.23mm

2

76.5

R1 5

1 P

3 R2

< >: AC

Dimensions

n

L

2

L1

50

3

70

L2

L3

L4

72

100

110.5

92

112.5

123

1.12-50

Equation L1=20n+10 L2=20n+32

4

90

112

137.5

148

5

110

132

162.5

173

6

130

152

175

185.5

7

150

172

200

210.5

8

170

192

212.5

223

9

190

212

237.5

248

10

210

232

262.5

273

11

230

252

275

285.5

12

250

272

300

310.5

13

270

292

312.5

323

14

290

312

337.5

348

15

310

332

362.5

373

16

330

352

375

385.5

n: Station (Max. 20 stations)

17

350

372

400

410.5

18

370

392

412.5

423

19

390

412

437.5

448

20

410

432

462.5

473

∗∗

VQZ Series 3/11/99 6:14 PM Page 51

Manifold Option

Blank plate assembly

VVQZ1000-10A-5

VVQZ2000-10A-5

VVQZ3000-10A-5

This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.

VQZ1000/2000/3000

Base Mounted

Interface speed control

(For VQZ2000 only)

VVQZ2000-20A-5

Actuator speed is controlled by throttling exhaust air flow.

Individual SUP spacer

VVQZ1000-P-5-M5

VVQZ2000-P-5-01

VVQZ3000-P-5-02

Used to form a separate supply port for an interior manifold station or stations.

Individual EXH spacer

VVQZ1000-R-5-M5

VVQZ2000-R-5-01

VVQZ3000-R-5-02

Used to form a separate exhaust port for an interior manifold station or stations.

M5: VQZ1000

Rc(PT)1/8: VQZ2000

Rc(PT)1/4: VQZ3000

VQ

VQ4

Dimensions

VQZ1000

VQZ2000

VQZ3000

A B

35 67

43

52

81

93

VQZ

VQD

VZS

VFS

M5: VQZ1000

Rc(PT)1/8: VQZ2000

Rc(PT)1/4: VQZ3000

VS

VS7

Dimensions

A B

VQZ1000

VQZ2000

VQZ3000

35

43

52

67

81

93

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

VP4

Port plug

VVQZ1000-CP

VVQZ2000-CP

VVQZ3000-CP

Used to block an unused cylinder port when using a 4 way valve as a 3 way valve.

∗∗

1.12-51

VQZ Series 3/11/99 6:15 PM Page 52

VQZ1000/2000/3000

Base Mounted

Manifold Option

Name plate [–N] (For VQZ2000 and 3000 only)

VVQZ2000-N5-

Station

VVQZ3000-N5-

Station

Transparent plastic plate to paste stickers on to identify the functions of each valve station.

· To order a manifold with nameplate already attached, insert "N" at

the end the manifold part number.

4 clips are attached for name plate mounting.

DIN rail

AXT100-DR-

l

Suffix the number from DIN rail dimensions table below.

Refer to manifold dimension drawings for L dimension.

To order a manifold with DIN rail already attached, insert “D” at the end of the manifold part number.

The DIN rail is approximately 30mm longer than the length of manifold.

L

12.5

(Pitch)

5.25

7.5

L dimension

No.

L

1

23

2

35.5

3

48

4

60.5

5

73

6

85.5

1.25

7

98

8

110.5

9

123

10

135.5

11

148

12 13

160.5

173

14

185.5

15

198

16 17

210.5

223

L=12.5n+10.5

18

235.5

19

248

20

260.5

No.

L

21

273

22

285.5

23

298

24

310.5

25

323

26

335.5

27

348

28

360.5

29

373

30

385.5

31

398

32 33

410.5

423

34

435.5

35

448

36 37

460.5

473

38

485.5

39

498

40

510.5

Fitting blank plug

KQP-23-X19

KQP-04-X19

KQP-06-X19

KQP-08-X19

KQP-10-X19

Color: White

L

A

Dimensions

Applicable fitting ød

3.2

4

6

8

10

Part number

KQP-23-X19

KQP-04-X19

KQP-06-X19

KQP-08-X19

KQP-10-X19

A L

(mm)

D

16

16

18

20.5

22

31.5

32

35

39

43

3.2

6

8

10

12

EXH port silencer

Silencer is installed in the EXH port.

38

63

AN110-01 AN200-02

Model

VQZ1000

VQZ2000

VQZ3000

Silencer P/N

AN110-01

AN200-02

AN200-02

∗∗

1.12-52

VQZ Series 3/11/99 6:15 PM Page 53

Specifications

Max. operating pressure

Min. operating pressure

Ambient and fluid temp.

Effective area (Cv)

(1)

Max. operating frequency

Dimensions

Valve

Mounting hole for

2-M3 3

Mounting hole for

2-M2.5

0.8MPa

0.15MPa

–5 to 50

°

C

2.7mm

2

(0.15)

180 c.p.m

VQZ1000/2000/3000

Base Mounted

Manifold Option

Double check block (Externally placed downstream): For VQZ1000 only

Using a 3 position exhaust center valve, this check block can stop and hold a cylinder in mid-stroke. The combination of a 2 position single or double solenoid with a double check block will prevent the cylinder from “dropping” at stroke end when residual supply pressure is released.

Note 1) As per JISB8375-1981

(Supply pressure: 0.5MPa)

2n-C4, C6

C6: One-touch fitting ass'y for ø4

C8: One-touch fitting ass'y for ø6

Manifold

l

Check Valve

Operational Principles

Cylinder side pressure (P2)

(P

2

)

L

IN

IN

OUT

OUT

To CYL port

SUP side pressure (P1)

SY

SYJ

SX

VK

15.5

L

3

L

2

L

1

P=11

2n-C4, C6

C4: One-touch fitting ass'y for ø4

C6: One-touch fitting ass'y for ø6

VZ

VF

VFR

VP7

VP4

29.5

38

(43) 2.5

Residual pressure release manual override

11

(17.5)

(22.5)

0.5

2n-C3, C4, C6, M5

C3: One-touch fitting ass'y for ø3

C4: One-touch fitting ass'y for ø4

C6: One-touch fitting ass'y for ø6

M5: M5 thread

Residual pressure release manual override

D side Stations

1 2

2n-C3, C4, C6, M5

C3: One-touch fitting ass'y for ø3

C4: One-touch fitting ass'y for ø4

C6: One-touch fitting ass'y for ø6

M5: M5 thread

3

DIN rail clamp screw n

U side

VQ

VQ4

VQZ

VQD

L

Dimensions

Equation L1=11n+20 n: Staion ( Max. 24 stations) n

1 2

3 4 5 6 7 8 9 10 11 12

L1

L2

L3

31

50

60.5

42

62.5

73

53

75

85.5

64

87.5

98

75

100

110.5

86

112.5

123

97

125

135.5

108

125

135.5

119

137.5

148

130

150

160.5

141

162.5

173

152

175

185.5

L

L1 n

L2

L3

13

163

187.5

198

14

174

187.5

198

15

185

200

210.5

16

196

212.5

223

17

207

225

235.5

18

218

237.5

248

19

229

250

260.5

20

240

250

260.5

21

251

262.5

273

22

262

275

285.5

23

273

287.5

298

24

284

300

310.5

VZS

VFS

VS

VS7

How to Order

Double check block

VQ1000–FPG– C4 M5 F

R1

P

R2

2 position

<Examples>

R1

P

R2

3 position/exhaust center

R1

P

R2

R1

P

R2

Option

IN side port size

C4

C6

One-touch fitting for ø4

One-touch fitting for ø6

Manifold

VVQ1000–FPG– 06

Stations

01

16

None

OUT side port size

M5

C3

C4

C6

DIN rail mounted

M5 therad

D

(for manifold)

One-touch fitting for ø3.2

F

With bracket

One-touch fitting for ø4

One-touch fitting for ø6

N

With name plate

Note)When specifying more than

one symbol, indicate them

Drop prevention

Stop in the middle

Caution

alphabetically.

Ex.) -DN

B A B A

P

Since air leakage from the pipe between the valve and cylinder or the fittings will prevent the cylinder from

stopping for a long time. Check for air leakage using neutral household detergent, such as dish washing

1 stations

16 stations

<Example>

VVQ1000–FPG–06 …6 stations of manifold

VQ1000–FPG–C4M5-D, 3 sets

VQ1000–FPG–C6M5-D, 3 sets

Double check block

soap. Also check the cylinder's tube gasket, piston seal and rod seal for leakage.

P

Since slight air leakage from One-touch fittings is allowed, use of a piping screw (with M5 thread) is

recommended when stopping the cylinder in the middle for a long time.

P

Combining double check block with 3 position closed center or pressure center solenoid valve will not work.

P

A M5 fitting assembly is attached, without being incorporated in the double check block. After screwing in

the fittings, mount the ass'y on the double check block. (Tightening torque: 0.8 to 1.2 Nm)

P

If exhaust side of double check block is narrowed down so much, this decreases the

intermediate stop accuracy.

1.12-53

∗∗

VQZ Series 3/11/99 6:15 PM Page 54

VQZ1000/2000/3000

Base Mounted

Manifold Option

Double check block (Externally placed downstream): For VQZ2000 only

Using a 3 position exhaust center valve, this check block can stop and hold a cylinder in mid-stroke. The combination of a 2 position single or double solenoid with a double check block will prevent the cylinder from “dropping” at stroke end when residual supply pressure is released. l

Check Valve

Operational Principles

Cylinder side pressure

(P

2

)

IN

IN

Specifications

Max. operating pressure

Min. operatingpressure

Ambient and fluid temp.

Effective area (Cv)

(1)

Max. operating frequency

Dimensions

Valve

0.8MPa

0.15MPa

–5 to 50

°

C

18mm

2

(1.0)

180 c.p.m

Note 1) As per JISB8375-1981

(Supply pressure: 0.5MPa)

To CYL port

SUP side pressure (P1)

Mounting hole for 2-M4

4.5

Mounting hole for 2-M6

B

A

2

4

2-Rc(PT)1/8, 1/4, C6, C8

C6: One-touch fitting ass'y for ø6

C8: One-touch fitting ass'y for ø8

Manifold

DIN rail clamp screw

B

A

4

2

A

B

4

2

A

B

2

4

2-Rc(PT)1/8, 1/4, C6, C8

C6: One-touch fitting ass'y for ø6

C8: One-touch fitting ass'y for ø8

L3

L2

L1

23 P=22

IN IN IN

IN

L

Residual pressure release manual override

D side Stations

1

2-Rc(PT)1/8, 1/4, C6, C8

C6: One-touch fitting ass'y for ø6

C8: One-touch fitting ass'y for ø8

2 3 n

U side

7 20.5

58

(59.5)

Residual pressure release manual override

22

(33)

(41.5) 1.5

2-Rc(PT)1/8, 1/4, C6, C8

C6: One-touch fitting ass'y for ø6

C8: One-touch fitting ass'y for ø8

2

4

B

A

2

4

B

A

2

4

B

A

B

2

A

4

L

Dimensions

n

1 2 3

L1

46

68 90

4

112

L2

75 87.5

112.5

137.5

L3

85.5

98

123 148

5

134

162.5

173

6

156

175

185.5

7

178

200

210.5

8

200

225

235.5

9

222

250

260.5

Equation L1=22n+24 n: Station

10

244

262.5

273

11

266

287.5

298

12

288

312.5

323

13

310

337.5

348

14

332

362.5

373

15

354

375

385.5

16

376

400

410.5

How to Order

Double check block

<Examples>

R1

2 position

3 position/exhaust center

R1 R1 R1

VQ2000–FPG– 01 01 F

R2 R2 R2 R2

Option

IN side port size

01

02

C6

C8

Rc(PT)1/8

Rc(PT)1/4

One-touch fitting for ø6

One-touch fitting for ø8

Manifold

VVQ2000–FPG– 06

1.12-54

OUT side port size

Stations

01

1 stations

16

16 stations

<Example>

VVQ2000-FPG-06 …6 stations of manifold

01

02

C6

C8

Rc(PT)1/8

Rc(PT)1/4

One-touch fitting for ø6

One-touch fitting for ø8

Double check block

F

D

None

With bracket

DIN rail mounted

(for manifold)

With name plate

N

Note)When specifying more than

Drop Stop

Caution

one symbol, indicate them

alphabetically.

prevention in the middle

Ex.) –DN

B A

A B

P

Since air Ieakage from the pipe between the valve and cylinder or the fittings will prevent the cylinder from stopping for a long time. Check for air leakage using neutral household detergent, such as dish washing soap.

Also check the cylinder’s tube gasket, piston seal and rod seal for leakage.

P

Since slight air leakage from One-touch fittings is allowed, use of a piping screw (with M5 thread) is recommended when stopping the cylinder in the middle for a long time.

P

Combining perfect block with 3 position closed center or pressure center solenoid valve will not work.

P

When screwing the fittings in the double check block, applied torque is as shown below:

Thread

Rc(PT)1/8

Rc(PT)1/4

Torque Nm

7 to 9

12 to 14

P

Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.

P

If exhaust side of double check block is narrowed down so much, this decreases of the intermediate stop accuracy.

∗∗

VQZ Series 3/11/99 6:15 PM Page 55

VQZ1000/2000/3000

Base Mounted

Compact Body Style with Built–in Speed Controller: For VQZ2000 Only

· Speed controllers are built-in to the valve body, making it easier

to adjust cylinder speed.

· Needle valve is equipped with a retainer to prevent accidental

needle loss.

symbol

(Single)

Flow rate

200

100

1 2 3 4 5 6 7 8 9

0.7MPa

0.5MPa

0.3MPa

0.15MPa

10

Fully open

Number of needle rotations (turns)

Specifications

Number of

Note 1) Valve with built-in speed controls is avaiable on rubber seal models only.

Note 2) Compact body valves and standard valves are not interchangeable.

Compact valves cannot be mounted on a standard manifolds and vice versa.

Note 3) Tightening torque of needle valve lock nut shoud not exceed 0.3Nm.

solenoids

Single

Double

Closed center

Exhaust center

Pressure center

Model

Metal

Rubber

Rubber w/ sp.controller

Metal

Rubber

Rubber w/ sp.controller

Metal

Rubber

Rubber w/ sp.controller

Metal

Rubber

Rubber w/ sp.controller

Rubber

Rubber w/ sp.controller

VQZ2150– l

–C

VQZ2151– l

–C

VQZ2151S– l

–C

VQZ2250– l

–C

VQZ2251– l

–C

VQZ2251S– l

–C

VQZ2350– l

–C

VQZ2351– l

–C

VQZ2351S– l

–C

VQZ2450– l

–C

VQZ2451– l

–C

VQZ2451S– l

–C

VQZ2551– l

–C

VQZ2551S– l

–C mm 2 (Cv)

(2)

(1) Response time (ms)

Effective area

Standard:

1W

(3)

High pressure

: 1.0W

Low wattage

AC

Weight

(g)

2.7(0.15) 12 or less 15 or less

40

3.6(0.2) 15 or less 20 or less

2.2(0.12)

2.7(0.15)

3.6(0.2)

2.2(0.12)

2.0(0.11)

2.7(0.15)

2.2(0.12)

2.0(0.11)

2.7(0.15)

2.2(0.12)

2.7(0.15)

2.2(0.12)

15 or less

10 or less

15 or less

15 or less

20 or less

25 or less

25 or less

20 or less

25 or less

25 or less

25 or less

25 or less

20 or less

13 or less

20 or less

20 or less

26 or less

33 or less

33 or less

26 or less

33 or less

33 or less

33 or less

33 or less

44

54

58

54

58

54

58

54

58

Note 1) Valve for sub-plate and maximum diameter.

Note 2) As per JISB8375-1981 (Supply pressure: 0.5MPa; with indicator

light and surge voltage suppressor; clean air)

The response time is subject to the pressure and the air quality.

The values at the time of ON are given for double styles.

Note 3) Weight without sub-plate

SY

SYJ

SX

VK

VZ

VF

VFR

VP7

How to Order Manifold

VP4

VV5QZ25C 05 C4 C

Series

2 VQZ2000

Manifold

5

Base mounted style

Compact body

Stations

02

2 stations

20

20 stations

Port size {4(A), 2(B) port}

C3

C4

C6

01

One-touch fitting for ø3.2

One-touch fitting for ø4

One-touch fitting for ø6

Rc(PT)1/8

The One-touch fittings on the compact manifold are pressed in and therefore cannot be changed out.

VQ

VQ4

VQZ

How to Order Valve

VQD

5 M C

VZS

VQZ2 1

1

2

3

4

5

(1)

Symbol

2 position single

2 position double

3 position closed center

3 position exhaust center

3 position pressure center

Note 1) Except for metal seals.

5 1

Compact body

Port size {4(A), 2(B) port}

Symbol

01

Port size

Without sub-plate

Rc (PT) 1/8

Manual override

B

Non-locking push style (Flush)

Locking style (Slotted)

VFS

VS

VS7

Body

5

Base mounted

0

1

Seal

Metal seal

Rubber seal

Speed controller

S

(1)

Without

With

Note 1)

Available with rubber seal

valve only.

Pilot valve specifications

Symbol

Specification

Standard

DC AC

(1.0W) v v

(2)

K

(1)

Y

High pressure

(1.0W) v

Low wattage

(0.5W) v

Note 1) Option

Note 2) Refer to p.1.12-35 for power

consumptionof AC type.

Note 3) When specifying more than one

option, indicate them alphabetically.

G

L

LO

M

MO

Coil voltage

1

2

3

4

100V AC (50/60Hz)

200V AC (50/60Hz)

110V AC (50/60Hz)

220V AC (50/60Hz)

5

6

9

24V DC

12V DC

Others

Contact SMC when requiring

Grommet AC specification and other voltages .

Electrical entry

Grommet (DC specificatiopn)

L plug connector with lead wire

L plug terminal without connector

M plug connector with lead wire

M plug terminal without connector

With light and surge suppressor for L, LO, M, MO

1.12-55

∗∗

VQZ Series 3/11/99 6:16 PM Page 56

VQZ1000/2000/3000

Base Mounted

Dimensions: VQZ2000

Grommet(G)

(5.5)

(35)

11

2- ø5.5 Mounting holes

Manual override

U Side

n

3

2

5

4

1

Station

D Side

13

72 (Single)

0.5

107 (Double)

116 (3 Position)

Cross section 0.34mm

2

33

25

11.8

(11)

(7.5)

7.4

2n-01, C4, C6

01: Rc(PT)1/8

C4: One-touch fitting for ø4

C6: One-touch fitting for ø6

3 R

1 P

2-Rc(PT)1/8

R(EXH)port

2-Rc(PT)1/8

P(SUP)port

14.6

45.5

23.4

4

L type plug connector (L)

120.5 (3 Position) <127.5>

111 (Double) <118>

74.5 (Single) <78>

Indicator light Cross section 0.23mm

2

10.3

7.4

Rc(PT)1/8

The broken line indicate DIN rail mounted style [-D]

M type plug connector (M)

300

(Lead wire length)

131 (3 Position) <141>

121.5 (Double) <131.5 >

79.5 (Single) <84.5>

Indicator light

1 P

Cross section 0.23mm

2

3 R

1 P

3 R

< >: AC < >: AC

Dimensions

L n

2

L1

43

L2

L3

L4

52

75

85.5

3

59

68

87.5

98

Equation L1=16n r

11 L2=16n r

20

4

75

5

91

6

107

7

123

8

139

84

112.5

123

100

125

135.5

116

137.5

148

132

162.5

173

148

175

185.5

1.12-56

9

155

164

187.5

198

10

171

180

200

210.5

11

187

196

225

235.5

12

203

212

237.5

248

13

219

228

250

260.5

14

235

244

275

285.5

15

251

260

287.5

298

16

267

276

300

310.5

17

283

292

312.5

323 n: Station (Max.20 stations)

18

299

308

337.5

348

19

315

324

350

360.5

20

331

340

362.5

373

∗∗

VQZ Series 3/11/99 6:16 PM Page 57

VQZ1000/2000/3000

Base Mounted

One Side Solenoid (Latching Solenoid)

The standard 2 position double solenoid valve has two solenoids, one on each end of the valve body.

The latching solenoid option(with self holding mechanism)functions in the same manner as a

2 position double solenoid but uses only one solenoid to do the job.

Manual override

One side solenoid

(Latching solenoid)

Latching solenoid

SY

SYJ

Existing model

How to Order Latching Solenoid Valve

VQZ 1 2 5 0 L 5 M

SX

VK

Series

1

2

3

VQZ1000

VQZ2000

VQZ3000

Port size

Electrical entry(L, M)

Coil voltage

Combination symbol

Body

Seal

Function

(2)

L

Latcing double

Wiring

Lead wires are connected to the valve as shown below. Connect them with the power supply.

Note 1) Specifications are same as standard except for

the function.

Note 2) K(High pressure style) and Y(Low wattage style)

are not available.

Electrical Circuit

Positive COM specification

Lead wire

24V DC 200V AC

Negative COM specification

Lead wire

24V DC

SOL.A

(–)

Black (Yellow) [Yellow]

SOL.A

(+)

Red

COM

(+)

SOL.B

(–)

Red (Blue)

White (Gray)

[Red]

[Gray]

COM

(–)

SOL.B

(+)

Black

White

Double solenoid Note ) ( ): 100V, 110V AC

[ ]: 200V, 220V AC

Black, (Yellow), [Yellow]:

A side solenoid (–)

3-core cable X 24AWG

Red, (Blue), [Red]

: COM (+)

3-core cable X 24AWG

White, (Gray), [Gray]

: B side solenoid (–)

Caution

Cautions for Latching Use

Double solenoid

Red: A side solenoid (+)

Black: COM (–)

White: B side solenoid (+)

Manual Override

The manual override is on the pilot valve for latching solenoid valves.

VZ

VF

VFR

VP7

VP4

VQ

Latching solenoid (DC)

VQ4

A–(Set)

VQZ

C+(COM)

SOL.

VQD

B–(Reset)

VZS

Latching solenoid (AC)

A Set

VFS

B COM

SOL.

VS

C Reset

Note 1) ·Set side in energized state: Lighting (Orange)

·Reset side in energized state: Lighting (Green)

·With miss-wiring preventing function (Stop diode)

·With surge absorption function (ZNR/Surge

absorption diode)

Note 2) Flow direction: P

R

A {A (set) side in energized state}

Flow direction: P

R

R {B (reset) side in energized state}

Note 3) Negative COM specification available.

VS7

1. Use a circuit in which the ON and OFF signals are not simultaneously

energized.

2. Minimum energization time for self holding is 20ms.

3. Avoid using the latching solenoid valves in environments where

impact or collisions with the valve might occur. Also, do not use in

places where a strong magnetic fields are present.

4. The armature in the solenoid is set in the B side ON position (Reset)

at the factory. However, shifting of the armature might occur during

shipping so please confirm the position by energizing the solenoid.

5. Please consult SMC for extended energization applications.

Blanking

Manual override

·To lock in set position (Flow path: P

R

A):

Turn the manual override clockwise by

180

°

to mark A press down. Valve is now

locked in the set condition.(Flow path: P

R

A)

·To reset (Flow path: P

R

B):

Turn manual override counterclockwise

to mark B and press down. Valve will

then be in the reset condition. (Flow

path: P

R

B).

1.12-57

∗∗

VQZ Series 3/11/99 6:16 PM Page 58

Series

VQZ

Options

Base Mounted

External Pilot Specifications

The external pilot specification must be used when the operating pressure is below the minimum operating pressure 0.1 to 0.2 MPa or when valve is being used for a vacuum application.

For the external pilot valve, an “R” should be attached to the valve and the manifold part number.(See the below.)

Example/Valve

VQZ2150R

5M

02

External pilot specification

Example/Manifold

VV5QZ25

06C6C

R

External pilot specification.

External pilot port

M5x0.8

Pressure Specifictions

Series

VQZ1000, 2000, 3000

2 position single 2 position double 3 position

Metal seal

0.1 to 0.7 MPa

Only VQZ3000, 3 position

0.15 to 0.7MPa

External pilot pressure range

Rubber seal

0.15 to 0.7MPa

0.1 to 0.7MPa

0.2 to 0.7MPa

Vacuum to 0.7MPa

and external pilot pressure range is 1MPa

.

Inch Size One–touch Fittings and Option Thread

Manifolds are available with inch size and One-touch fittings for the cylinder ports.

Sub-bases and manifolds with NPT, NPTF or PF threads are available.

How to Order Manifold

VV5QZ15

08 N7

T

C

N

Thread

(Cylinder ports and

P, R ports)

N

T

F

Rc(PT)

NPT

NPTF

G(PF)

Cylinder ports

Symbol

N1 N3 N7 N9 N11

Applicable tube O.D.(Inch) ø

1

/

8

” ø

5

/

32

” ø

1

/

4

” ø

5

/

16

” ø

3

/

8

V

V

NM

(1)

Mix

M5 01 02

M5 1/8 1/4

V V

— —

VQZ1000

Cylinder port

VQZ2000

VQZ3000

V

V

V

V

V

V

V

V

V

V

V

Note 1) Mixing One-touch fittings and thread types is impossible.

Note 2) Millimeter sizes of One-touch fittings (C ) are also available.

How to Order Valve with Sub-plate

VQZ2151 5M 02 T

Thread

(Cylinder ports and P, R ports)

N

T

F

Rc(PT)

NPT

NPTF

G(PF)

Dust Tight/Jet Proof (IP65)

Optional IP65 model is available on valves with DIN connector electrical entry.

How to Order Valve

(Applicable to VQZ2000/3000 rubber seal)

VQZ3151 5YZB W 03

IP65 rated

W

(1)

No (Standard)

IP65 reted

Note 1)

The pilot exhaust of the

IP65 valves is common with main valve exhaust.

(The standard valve has an individual exhaust for the pilot valve.)

1.12-58

∗∗

VQZ Series 3/11/99 6:17 PM Page 59

Series

VQZ

Base Mounted

Replacement Parts

One-touch Fitting Assembly (For cylinder port)

Fitting Size

C3 C4

Series

VQZ1000

VVQ1000-50A-C3 VVQ1000-50A-C4

VVQ1000-51A-C4

VQZ2000

VQZ3000

Note) Order is accepted in 10 units.

<Plug connector assembly>

DC (+COM)

· Single

· Latching

AXT661–14A–

AXT661–13A–

DC (-COM)

· Latching

AXT661–13AN–

100V, 110V AC

· Single

AXT661–31A–

· Latching

AXT661–32A–

200V,220V AC

· Single

AXT661–34A–

· Latching

AXT661–35A–

Only connector and

sockets (3 pcs.)

AXT661–12A

6

10

20

30

Lead wire length

300mm

600mm

1000mm

2000mm

3000mm

Standard wire length of valve with plug connector is 300mm.

When requiring valve with 600mm length lead wire specify the model number of valve without plug connector and plug connector assembly.

C6

VVQ1000-50A-C6

VVQ1000-51A-C6

VVQ2000-51A-C6

C8

VVQ1000-51A-C8

VVQ2000-51A-C8

C10

VVQ2000-51A-C10

SY

SYJ

<Gasket and screw assembly>

VQZ1000

VQZ2000

VQZ3000

Part No.

VQZ1000-GS-5

VQZ2000-GS-5

VQZ3000-GS-5

SX

VK

Note ) Above part number consists of 10 units.

Each unit has one gasket and two screws.

Orders are accepted in 10 units.

VZ

VF

VFR

VP7

VP4

VQ

<Pilot valve assembly>

VQ4

VQZ

VQ11 1

– –

VQD

VZS

VFS

Series Applicable model

1

VQZ1000, 2000, 3000

4

VQZ2000, 3000

A and B side of VQZ1000 single double solenoid type

A side of VQZ1000 3 position

Function

Symbol Specification DC

Standard

(1.0W) v

K

(1) High pressure

(Metal seal)

(1.0W) v

Y

L

(3)

Low wattage

Latching

(0.5W) v

(1.0W) v

AC v v

Note 1) Option

Note 2) When specifying more than one option,

please indicate them alphabetically.

Note 3) K (High pressure) and

Y (Low wattage) are not available.

Electrical entry: L/ M plug connector only.

1

2

3

4

5

6

9

Coil voltage

100V AC (50/60Hz)

200V AC (50/60Hz)

110V AC (50/60Hz)

220V AC (50/60Hz)

24V DC

12V DC

Others

Consult SMC when requiring grommet style, AC specification and others.

5

B side of VQZ1000 3 position

G

L

(1)

LO

(1)

M

(1)

MO

(1)

Y

(2)

YO

(2)

YZ

(2)

YOS

(2)

Electrical entry

Grommet (DC specification)

L plug connector with lead wire

L plug terminal without connector

M plug connector with lead wire

M plug terminal without connector

DIN connector

DIN terminal without connector

DIN connector

DIN terminal without connector

Note 1) L, LO, M and MO types are attached with light

and surge voltage suppressors as standard.

Note 2) DIN style is applicable to VQZ2000, 3000.

<Sub-plate>

Model

VQZ1000

VQZ2000

VQZ3000

Sub-plate part No.

VQZ1000-S-01

VQZ2000-S-

01 [Rc1/8]

02 [Rc1/4]

VQZ3000-S-

02 [Rc1/4]

03 [Rc3/8]

VS

VS7

1.12-59

∗∗

advertisement

Related manuals