51PS V
V SERIES
High Reliability Switchers
Single & Quad Outputs
120-600 Watts
FEATURES
Single and quad output, 120-600 watts
Ultra-low cost open frame switchers
Dual loop regulation system
Fast stock delivery
200K - 1 million hours MTBF
80% typical efficiency
SINGLE OUTPUT
Max Power
120W
120W
120W
120W
180W
180W
180W
180W
250W
250W
250W
250W
270W
270W
270W
270W
360W
360W
360W
360W
500W
500W
500W
500W
600W
600W
600W
600W
Output
5V @ 25A
12V @ 10A
15V @ 8A
24V @ 5A
5V @ 36A
12V @ 15A
15V @ 12A
24V @ 7.5A
5V @ 50A
12V @ 21A
15V @ 17A
24V @ 11A
5V @ 54A
12V @ 22A
15V @ 18A
24V @ 12A
5V @ 72A
12V @ 30A
15V @ 24A
24V @ 15A
5V @ 100A
12V @ 42A
15V @ 33A
24V @ 21A
5V @ 120A
12V @ 50A
15V @ 40A
24V @ 25A
Model
V120AXX
V120BXX
V120CXX
V120DXX
V180AXX
V180BXX
V180CXX
V180DXX
V250AXX
V250BXX
V250CXX
V250DXX
V270AXX
V270BXX
V270CXX
V270DXX
V360AXX
V360BXX
V360CXX
V360DXX
V501AXX
V501BXX
V501CXX
V501DXX
V601AXX
V601BXX
V601CXX
V601DXX
DESCRIPTION
V Series World Class switching power supplies are a family of single and quad
output models designed for a wide variety of commerical and industrial
applications. These industrial workhorses have demonstrated MTBF ratings
greater than 500,000 hours. A proprietary proportional drive circuit prevents
excess switch saturation and permits higher switching frequency operation.
This makes possible increased reliability and a compact size.
One of the unique features of the V Series is a dual loop regulation system.
This system provides a tightly regulated main output and eliminates cross
regulation in the auxiliaries.
QUAD OUTPUT
Max
Power
225W
225W
225W
225W
225W
325W
325W
325W
325W
325W
Output 1
Output 2
Output 3
Output 4
Model
5V @ 30A
5V @ 30A
5V @ 30A
5V @ 30A
5V @ 30A
5V @ 45A
5V @ 45A
5V @ 45A
5V @ 45A
5V @ 45A
+12V @ 6(12)A
+12V @ 6A
+15V @ 6(12)A
+15V @ 6A
+12V @ 6(12)A
+12V @ 8(16)A
+12V @ 8A
+15V @ 8(16)A
+15V @ 8A
+12V @ 8(16)A
-12V @ 4A
-12V @ 4A
-15V @ 4A
-15V @ 4A
-12V @ 4A
-12V @ 6A
-12V @ 6A
-15V @ 6A
-15V @ 6A
-12V @ 6A
-5V @ 4A
+24V @ 4(8)A
-5V @ 4A
+24V @ 4(8)A
+12V @ 4A
-5V @ 4A
+24V @ 4(8) A
-5V @ 4A
+24V @ 4(8)A
+12V @ 4A
V225AXX
V225BXX
V225CXX
V225DXX
V225EXX
V325AXX
V325BXX
V325CXX
V325DXX
V325EXX
Important Notes:
1. Numbers in parentheses are peak ratings for a short duration service such as motor starting.
Replace the "XX" with the sum of the Option Codes.
2. Output 1 is floating and can be either polarity.
Other voltages, e.g. 2V, 3.3V, 28V and 48V
available on special order.
3. Quads require 10% of maximum power distributed among auxiliary outputs for optimum performance.
4. Outputs can operate to no load with slight increase in specifications.
5. For agency certifications, units must be purchased with 04 Option.
OPTIONS
Option Code
00
01
02
04
08
16
Function
None
OVP protects all auxiliaries
Power Fail Monitor
Thermal Shutdown
Cover
Logic Inhibit
Replace the "XX" with the sum of the Option Codes.
Deltron Inc.
290 Wissahickon Avenue, North Wales, PA 19454
Phone: 800.523.2332
Fax: 215.699.2310
Email: [email protected]
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
V SERIES SPECIFICATIONS
INPUT
90-132 VAC or 180-264 VAC, 47-440 Hz.
operation.
Consult factory for 400 Hz.
EMISSIONS
FCC 2070 Part 15, Class A/EN 55022, Class A Conducted. EN 60 5553/EN 61000-3-3, Voltage Fluctuations.
IMMUNITY
EN 61000-4-2, Electrostatic Discharge.
IEC 1000-4-3, Radiated Field.
IEC 1000-4-4, Electrical Fast Transients.
EN 61000-4-5, Level 3 Surge.
IEC 1000-4-6, Conducted Field.
INPUT SURGE
17 amps peak from cold start for models up to 250 watts or less, 68 amps
for other models, from nominal 110 or 220 VAC.
EFFICIENCY
80% typical.
DYNAMIC RESPONSE
Peak transient less than ±2% or ±200 mV for step load change from 75%
to 50% or 100% max. ratings.
RECOVERY TIME
Less than 400 microseconds on main/singles output.
Less than 50 microseconds on post regulated auxiliaries.
SAFETY
Units meet UL 1950/60950, CSA 22.2 No. 60950-00, EN 60 950, IEC 950.
DIELECTRIC WITHSTAND
3750 VRMS input to ground.
3750 VRMS input to output.
700 VDC output to ground.
SPACING
8 mm primary to secondary. 4 mm primary to grounded circuits.
LEAKAGE CURRENT
0.75 mA at 115 VAC, 60 Hz. input.
HOLDUP TIME
20 milliseconds after loss of nominal AC power.
AC INPUT UNDERVOLTAGE
Proprietary proportional drive and low voltage lockout protects against
damage for undervoltage operation.
OUTPUTS
See table of models.
SOFT START
Units have soft start feature to protect critical components.
LINE REGULATION
±0.1% for line change from nominal to min. or max. rating with 20% min.
load on the measured output. Singles to no load.
OVERVOLTAGE PROTECTION
Standard on main output/singles. Optional on auxiliaries.
LOAD REGULATION
5V main/singles ±0.2%
-5V aux. ±3%
±12V aux. ±2%
±15V aux. ±2%
+24V aux. ±1.5%
for load change from 60% to 20% or 100% max. rating. Singles to no load.
CROSS REGULATION
±0.2% for load change on the main 5V output from 75% to 50% or 100%
max. rating with 20% min. load on the measured output. Not applicable to
singles.
CENTERING
5V main/singles ±5% trim adj.
1st and 2nd aux. ±5% trim adj. tracking
3rd aux.: -5V ±3%, +12V ±2%, +24V ±1%
with all outputs loaded to 50% max. ratings and output #2 set precisely at
its rated value.
RIPPLE & NOISE
1% or 100 mV, pk.-pk., 20 MHz bandwidth.
OPERATING TEMPERATURE
0-70°C. Derate 2.5%/°C above 50°C.
COOLING
Models
Forced Air
V120, V180, V225,
V250, V270, V360
30 CFM
V325, V501, V601
60 CFM
TEMPERATURE COEFFICIENT
5V main/singles ±0.02%/°C
Auxiliaries ±0.05%/°C
REVERSE VOLTAGE PROTECTION
All outputs are protected up to load ratings.
OVERLOAD
Outputs short circuit protected by current foldback with automatic
recovery. Post regulators have individual current foldback protection.
REMOTE SENSING
On 5V main/singles which are fully isolated from all auxiliaries.
SHOCK
MIL-STD 810-E Method 516.4, Procedure I.
VIBRATION
MIL-STD 810-E Method 514.4, Category 1, Procedure I.
OPTIONS
POWER FAIL MONITOR (CODE 02)
Optional monitor provides a TTL signal 2 ms. min. prior to loss of output
power with outputs fully loaded from 100VAC/200VAC line loss.
THERMAL SHUTDOWN (CODE 04)
Optional circuit cuts off supply in case of local over temperature. Unit
resets automatically when temperature returns to normal.
COVER (CODE 08)
Option cover for safety and EMI.
uncovered units.
Place fan for comparable flow as in
INHIBIT (CODE 16)
Optional TTL logic inhibit input.
AUTO RANGER
Model AR-1 accessory provides automatic operation at specified input
ranges without strapping.
Specifications subject to change without notice.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
V SERIES DIMENSIONS
DIMENSIONS INCHES
MM
SERIES V120, V180, V250.
0.75
19.1
6-32
CLINCH NUT
(4 PLACES)
SERIES V270, V360, V501, V601.
8-32/M4
CLINCH NUT
1.05
26.7
(3 PLACES)
8-32/M4
CLINCH NUT
6-32
CLINCH NUT
0.75
19.1
INPUT
1.05
26.7
(3 PLACES)
(6 PLACES)
INPUT
4.50
8.50
215.9
7.00
177.8
7.00
177.8
9.00
228.6
3.90
10.3
99.1
228.6
OUTPUT
END
1.31
33.3
0.41
3.90
10.3
99.1
4.75
1.31
33.3
4.75
* 120.6
* 120.6
1/4-20 STUD
(2 PLACES)
9.00
10.50
266.7
OUTPUT
END
0.41
4.50
114.3
114.3
4.50
114.3
5.00
2.50
63.5
5/16-18 STUD
* 127.0
(2 PLACES)
WITH
OPTIONAL
COVER
5.00
* 127.0
2.50
63.5
WITH
OPTIONAL
COVER
SERIES V225, V325.
0.75
19.1
6-32
CLINCH NUT
8-32/M4
CLINCH NUT
(6 PLACES)
1.05
26.7
(3 PLACES)
INPUT
4.50
4.50
114.3
114.3
10.50
266.7
9.00
228.6
9.00
228.6
OUTPUTS
AUX
MAIN
0.55
14.0
TERMINAL
BLOCK
3.90
99.1
5.00
127.0
1.31
33.3
#10-32 STUD
(2 PLACES)
2.50
63.5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement