datasheet for M9505A by Agilent

datasheet for M9505A by Agilent
Agilent M9502A
and M9505A
Data Sheet
2 and 5-Slot
AXIe Chassis
Challenge the Boundaries of Test
Challeng
Agilent Modular Products
INT ROD UC T ION
Pr o du c t d e s c ri p t i o n
The M9502A and M9505A AXIe chassis are fully compatible with the AXIe 1.0 specification. They provide 2 or 5
slots for AXIe instrument modules, and have an embedded
system module that does not take up an instrument slot.
The embedded system module (ESM) provides Gigabit LAN
and Gen 2 x8 PCIe interfaces for connecting the chassis to
an external controller. To minimize rack space, the instrument module slots are arranged horizontally. In addition,
the chassis are designed to be easily maintained. Both the
power supply and fan tray can be removed with modules
installed while the chassis remains in the rack.
F eatures
• AXIe 1.0 compliant
• Embedded system module with Gen 2 PCIe x8 and
Gigabit LAN interfaces for connecting to host computer
• Agilent-exclusive, built-in inter-chassis synchronization
for multi-chassis systems
• 62 differential local bus lines provide very large data
path between adjacent modules
• High power with 200W cooling per slot
• Front-removable fan tray
Applic a tio n s
• Aerospace and defense
• Computation
C us to mer val ues
• Communications
• AXIe chassis provide a high-performance platform to
compliment PXI-based systems
• Electronics test
• Semiconductor testing
• The compact, 2-slot chassis is ideal for transportable
applications, but is also rack-mountable
• High-energy physics
• The 5-slot chassis provides a cost-effective solution
when more AXIe slots are required
• The embedded AXIe system module and horizontal
module placement save rack space, requiring only 2U or
4U, depending on model
• With the innovative cooling design, no additional rack
space is required to meet cooling specifications
2
EASY SET UP ... T ES T ... A N D M A I N T E N A N C E
H a r d w ar e p l a t f o rm
Bac k plane c onfiguration
Compliance
The AXIe backplane in the Agilent M9502A and M9505A
chassis include all of the following AXIe backplane lines:
The M9502A and M9505A chassis are fully compliant
with the AXIe 1.0 specification. In addition, the chassis
complies with AdvancedTCA (ATCA) PICMG 3.0 R2.0
specifications, and is electrically compatible with standard
ATCA modules.
• Timing and triggering signals including: 100 MHz clock,
100 MHz PCIe clock (FCLK), point-to-point star trigger
from ESM (SYNC), bi-directional point-to-point star
trigger (STRIG), and 12 signal parallel trigger bus (TRIG)
• Distributed PCIe Gen 2 data fabric from ESM (x4 to each
slot) plus a secondary PCIe data fabric
• Distributed gigabit Ethernet LAN to each slot
• 62-pair local bus for adjacent module signaling or data
transfer (AXIe only requires 18 pairs)
• DC power rail (normally 45-53 VDC)
• Intelligent Platform Management Bus (IPMB) for chassis
control, including module power-up
An additional half-height slot is built into the chassis and
reserved for the embedded system module. This slot is not
compatible with AXIe instrument modules or embedded
computers. Embedded controllers must be installed in one
of the instrument module slots.
Figure 1. 5-slot AXIe backplane
3
EASY SET UP ... T ES T ... A N D M A I N T E N A N C E
Figure 2. M9505A backplane block diagram
E m b e d d e d sy st e m m o d ul e ( ESM)
In addition to the required functions, the system module
also provides:
Both the M9502A and M9505A chassis contain an embedded system module that does not take up an instrument
slot. This module performs the chassis management functions contained in the AXIe specification, including:
• Ability to synchronize multiple chassis with trigger and
clocking signals (Mini D In/Out connectors)
• SMA connectors for external clock in/out and trigger
in/out
• Managing trigger and clock busses
• Managing clocks, including internal or external
reference sources
• Gen 2 x8 PCIe cable connector for connecting the chassis to an external computer
• Gigabit LAN switching with a front panel RJ45 LAN connection (see module documentation to determine if it is
supported for LAN communications)
• USB 2.0 option provides USB connectivity for some AXIe
modules. Only supported on a limited set of Agilent
modules. See module documentation to determine if it
supported for USB control.
• AXIe Fabric 1 switching (Gen 2 x4 lanes to each module
slot)
• Monitoring the health of the chassis subsystems and
modules
• Controlling the chassis cooling fans, and managing the
chassis power-up sequence
4
EASY SET UP ... T ES T ... A N D M A I N T E N A N C E
S of t w ar e p lat f or m
I n n o v a t i v e co o l i ng
The AXIe chassis utilize a cooling design that does not
require additional rack space to cool the modules. This
allows the chassis to fit into 2U or 4U of rack space.
Drivers
The M9502A and M9505A chassis come complete with IVICOM, IVI-C, and LabVIEW drivers. Windows XP®, Windows
Vista®, and Windows 7® operating systems are supported
and applications can be completed using many different
software tools including LabVEW, LabWindows/CVI,
MATLAB, VEE, VisualStudio.NET® (C/C++, C#, VB.NET).
The cooling design uses auto-speed fans to pull in cool
air. Air flows from right-to-left within the chassis. The ESM
provides intelligent control of the power supplies and fans
and ensures there is sufficient power/cooling for each
module.
Chass is Web server
L o we r m a i nt e nance co st s
Both AXIe chassis include a built-in Web server for configuration, control, and monitoring of the chassis.
This Web server can be accessed by either LAN or PCIe.
The chassis were designed to reduce maintenance costs.
The innovative air-flow design does not require air filters
to replace. In addition, the power supply and fans can be
removed while the chassis is mounted in a rack, allowing
the chassis to be serviced while keeping DUT cabling in
place.
The following functions are provided:
• Chassis information
• Chassis LAN configuration
• Instrument module inventory
• Trigger routing setup
• Chassis health (temperature, fan, power supply)
Soft front panel
A soft front panel interface is also provided to monitor and
control the AXIe chassis. It has some of the basic functionality of the chassis Web page and communicates to the
chassis using the IVI drivers. The soft front panel has two
screens: trigger routing and chassis monitor.
Figure 3. Chassis Web page
Figure 4. Chassis soft front panel interface
5
T ECHNIC A L S P EC IFIC A T I O N S A N D CH A R A CT E R I S T I CS
Chassis characteristics
Standards compliance
AXIe 1.0 Base Architecture specification
AdvancedTCA PICMG 3.0 R2.0 specification
Backplane
M9502A
M9505A
Total slots
2
5
Instrument module slots
2
5
Embedded
Embedded
M9502A
M9505A
100-240 VAC
100-240 VAC
50-60 Hz
50-60 Hz
System module
Power supply characteristics
AC input
Operating voltage range
Input frequency range
Input power consumption
Overcurrent protection
Efficiency (typical)
800 VA
1280 VA
Auto-recovery
Auto-recovery
85-90%
85-93%
DC supply
Model
DC output
Total DC
module power
Total max
module current
Load
regulation
Maximum ripple and
noise (20 MHz BW)
M9502A
50 V
400 W
8A
2%
1% pk-pk
M9505A
52 V
1000 W
19.2 A
2%
500 mV pk-pk
Chassis cooling and power dissipation
Slot airflow direction
Right to left
Chassis cooling intake
Right side of chassis
Chassis cooling exhaust
Left side of chassis
Chassis cooling fans
M9502A
M9505A
Three 90.0 cfm fans on fan tray with HIGH/AUTO speed selector
Six 90.0 cfm fans on fan tray with HIGH/AUTO speed selector
Power dissipation, instrument slot
200 W max
6
T E CHNICA L S P EC IFIC A T I O N S A N D CH A R A CT E R I S T I CS
Clocks and triggers
100 MHz system clock (CLK100)
Accuracy
± 20 ppm
Duty cycle
45/55%
Maximum slot-to-slot skew
100 ps
External clock in (SMA)
Input frequency
10 MHz ± 100 ppm
Input level
± 5 V, AC coupled
Minimum swing
250 mV
External clock out (SMA)
Output frequency
10 MHz
Output level
3.3 V CMOS
Output load
50 ohm
AXIe differential star trigger (STRIG)
Maximum slot-to-slot skew
100 ps
External trigger out (SMA)
Output level
3.3 V CMOS
Output load
50 ohm
External trigger in (SMA)
Input level
± 5 V, adjustable threshold
Input impedance
4 kohm (pulled up to 2.5 V)
Minimum swing
250 mV
Environmental characteristics 1, 2
Operating and storage conditions
Operating
Temperature
Storage
0˚C to 50˚C
-25˚C to 60˚C
Humidity
Type tested at 95%, +40˚C
(non-condensing)
Type tested at 95%, +40˚C
(non-condensing)
Altitude
up to 3000 meters
up to 4600 meters
Shock and vibration
Operating random vibration: type tested at 5 to 500 Hz, 0.21 g rms
Survival random vibration: type tested at 5 to 500 Hz, 2.09 g rms
Acoustical sound power (LWA dB, ref 1pW)
Worst case
Normal operation
(25˚C air intake)
M9502A
74.3
55.2
M9505A
77.6
62.8
1. Samples of this product have been type tested in accordance with the Agilent Environmental Test Manual and verified to be robust
against the environmental stresses of storage, transportation, and end-use; those stresses include but are not limited to temperature,
humidity, shock, vibration, altitude, and power line conditions.
2. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3
7
T E CHNIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S
Regulatory characteristics
Safety
Complies with European Low Voltage Directive 2006/95/EC
IEC/EN 61010-1, 2nd Edition
Canada: CSA C22.2 No. 61010-1-04
USA: UL std no. 61010-1, 2nd Edition
German Acoustic statement
Geraeuschemission
LpA < 70 dB
Am Arbeitsplatz
Normaler Betrieb
Nach DIN 45635 t.19
Acoustic noise emission
LpA < 70 dB
Operator position
Normal position
Per ISO 7779
EMC
Complies with European EMC Directive 2004/108/EC
IEC/EN 61326-1
Canada: CSA C22.2 No. 61010-1-04
CISPR Pub 11 Group 1, Class A
AS/NZS CISPR 11
ICES/NMB-001
This ISM device complies with Canadian ICES-001; cet appareil ISM est conforme a la norme NMB-001 du Canada
General characteristics
Mechanical
Weight (nom)1
Size with bumpers
Size without bumpers
M9502A
7.7 kg
(17 lbs)
462mm W x 102mm H x 414mm D
432mm W x 87mm H x 414mm D
M9505A
13.3 kg
(29.3 lbs)
462mm W x 193mm H x 436mm D
432mm W x 177mm H x 436mm D
1. Without modules
8
T E CHNIC A L S P EC IFIC A T I O N S A N D C H A R A C T E R I S T I C S
ESM front panel connectors
Multiframe
Clock
Synchronizes timing signals with
External clock connections
In Out
multiple daisy-chained chassis
Input
Output
LAN
Trigger
USB (Option U20)
Connects the host
Connects a host to the
External trigger
PC to the chassis, via
chassis via USB 2.0*
connections
10/100/1000 Ethernet
Out
In
PCIe
Status light
Connects a host PC to
Chassis status
the chassis via PCIe
indicator light
* USB port is only supported for a very limited set of Agilent AXIe modules. Check module documentation or go to:
www.agilent.com/find/axie-chassisusb for compatibility information.
System requirements
Operating
systems
Windows® XP,
Service Pack 3 or later (32-bit)
Windows Vista, SP1 and SP2
(32-bit and 64-bit), Business,
Ultimate, Enterprise, Home
Basic, and Home Premium
Windows 7 (32-bit and 64-bit)
Starter, Home Basic, Home
Premium, Professional,
Ultimate, Enterprise
Processor speed
600MHz or higher
required 800MHz
recommended
1Ghz 32-bit (x86), 1GHz 64-bit
(x64),no support for Itanium 64
1GHz 32-bit (x86), 1GHz 64-bit
(x64), no support for Itanium 64
Available memory 256 MB minimum (1 GB or
greater recommended)
1 GB minimum
1 GB minimum
Available disk
space 1
1.5 GB available hard disk
space, includes:
· 1GB available for Microsoft
.NET Framework 3.5 SP1 2
· 100MB for Agilent IO
Libraries Suite
1.5 GB available hard disk
space, includes:
· 1GB available for Microsoft
.NET Framework 3.5 SP12
· 100MB for Agilent IO Libraries
Suite
1.5 GB available hard disk
space, includes:
· 1GB available for Microsoft
.NET Framework 3.5 SP12
· 100MB for Agilent IO Libraries
Suite
Video
Super VGA (800x600)
256 colors or more
Support for DirectX 9 graphics
with 128MB graphics memory
recommended (Super VGA
graphics is supported)
Support for DirectX 9 graphics
with 128MB graphics memory
recommended (Super VGA
graphics is supported)
Browser
Microsoft® Internet Explorer
6.0 or greater
Microsoft Internet Explorer 7 or
greater
Microsoft Internet Explorer 7 or
greater
1. Because of the installation procedure, less memory may required for operation than is required for installation.
2. NET Framework Runtime Components are installed by default with Windows Vista and Windows 7. Therefore, you may not need this
amount of available disk space.
9
CONF IGURA T ION
H a r d w ar e
A c c es s o ri es
Model
Description
Model
Description
M9502A
2-slot AXIe chassis with embedded
system module
Y1225A
Rack mount kit for M9502A
Y1226A
Rack mount kit for M9505A
M9505A
5-slot AXIe chassis with embedded
system module
Y1223A
AXIe multi-frame cable: 0.5m
Includes:
AXIe filler modules, getting started guide,
drivers, and Agilent I/O libraries
Y1224A
AXIe multi-frame cable: 3m
Y1232A
Soft carry bag for M9502A
N5650-00080 Single slot AXIe filler module
R el ated p ro d uc ts
Y1200B:
x1 to x8
bles
PCIe cables
Y1202A:
x8 PCIe
cables
M9536A embeddedd
AXIe controller
M9045B PCIe
PC
ExpressCard
M9048A PCIe
adapter
Model
Description
M9536A
Embedded AXIe PC controller
M9045B
PCIe ExpressCard adaptor: Gen 1
Y1200B
PCIe cable: x1 to x8, 2.0 m (used with
M9045B)
M9048A
PCIe desktop PC adapter: Gen 2, x8
Y1202A
PCIe cable: x8, 2.0 m (used with
M9048A)
So ftw are
Laptop PC
Desktop or
rack mount PC
Figure 5. Configuration
R ec om m e n d e d c o n f i g u ra t i o n
Configure the Agilent M9502A and M9505A AXIe chassis,
as follows:
1. Configure the chassis connection to the host:
• If you are using PCIe to connect an external
computer, select an appropriate PC interface
card; the Agilent M9048A is recommended
• If the AXIe modules support USB (see
www.agilent.com/find/axie-chassisusb)
then you can use a USB cable to connect the
AXIe chassis to the host. A PCIe interface
card/cable is not required
2. If the M9536A embedded AXIe controller is used, it must
go into slot one (it does not replace the ESM)
3. Select an appropriate cable to connect the computer
interface board to the system module; the Y1202A is
recommended to connect the M9048A to the M9502A or
M9505A
4. Select rack mount and multi-chassis cables as required
10
Model
Description
Supported
operating
systems
Microsoft Windows® XP (32-bit),
Microsoft Windows® Vista (32/64-bit),
Microsoft Windows® 7 (32/64-bit)
Standard
compliant
drivers
IVI-COM, IVI-C, LabVIEW
Supported
application
development
environments
(ADE)
VisualStudio® (VB.NET, C#, C/C++),
LabVIEW, LabWindows/CVI, VEE
Agilent IO
Libraries
Includes: VISA Libraries, Agilent
Connection Expert, IO Monitor
WARRANTY AND CALIBRATION
ORD E RING
Model
Description
Advantage Services: Calibration and Warranty
M9502A
AXIe chassis: 2-slot with embedded
system module
Agilent Advantage Services is committed to your success throughout your equipment’s lifetime.
M9505A
AXIe chassis: 5-slot with embedded
system module
Opt 900-932
Optional power cords
Opt U20
ESM USB 2.0 1
Includes USB cable
Warranty 1
Standard warranty is 1 year
1. USB port is only supported for a very limited set of Agilent AXIe
modules. Check module documentation or go to: www.agilent.com/find/
axie-chassisusb for compatibility information
R-51B-001-3C
1 year return-to-Agilent warranty
extended to 3 years
R-51B-001-5C
1 year return-to-Agilent warranty
extended to 5 years
1. Options not available in all countries.
Defin itio n s f o r s p e c i f i c a t i o ns
Specifications describe the warranted performance of calibrated instruments that have been stored for a minimum of
2 hours within the operating temperature range of 0 °C
to 50 °C, unless otherwise stated, and after a 45 minute
warm-up period. Data represented in this document are
specifications unless otherwise noted.
Characteristics describe product performance that is useful
in the application of the product, but that is not covered by
the product warranty. Characteristics are often referred to
as Typical or Nominal values.
• Typical describes characteristic performance, which 80%
of instruments will meet when operated over a 20 °C
to 30 °C temperature range. Typical performance is not
warranted.
• Nominal describes representative performance that is
useful in the application of the product when operated
over a 20 °C to 30 °C temperature range. Nominal performance is not warranted.
Note: All graphs contain measured data from several units
at room temperature unless otherwise noted.
11
T h e M o d u l ar Tang r am
The four-sided geometric symbol that appears in this document is
called a tangram. The goal of this seven-piece puzzle is to create
identifiable shapes—from simple to complex. As with a tangram,
the possibilities may seem infinite as you begin to create a new
test system. With a set of clearly defined elements—hardware,
software—Agilent can help you create the system you need,
from simple to complex.
Challenge the Boundaries of Testt
dular Products
Agilent Modular
myAgilent
www.agilent.com/find/myagilent
A personalized view into the information most relevant to you.
TM
www.pxisa.org
www.axiestandard.org
Agilent Solutions Partners
www.agilent.com/find/solutionspartners
Agilent Advantage Services is committed to your
success throughout your equipment’s lifetime.
www.agilent.com/find/advantageservices
www.agilent.com
www.agilent.com/find/modular
www.agilent.com/find/axie-chassis
For more information on Agilent Technologies’ products,
applications or services, please contact your local Agilent office.
The complete list is available at: www.agilent.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
(11) 4197 3500
01800 5064 800
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 375 8100
Europe & Middle East
Belgium
Denmark
Finland
France
Germany
Ireland
Israel
Italy
Netherlands
Spain
Sweden
United Kingdom
32 (0) 2 404 93 40
45 70 13 15 15
358 (0) 10 855 2100
0825 010 700*
*0.125 €/minute
49 (0) 7031 464 6333
1890 924 204
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
44 (0) 118 9276201
For other unlisted Countries: www.agilent.com/find/contactus
Revised: October 14, 2010
PICMG and the PICMG logo, CompactPCI and the CompactPCI logo, AdvancedTCA
and the AdvancedTCA logo are US registered trademarks of the PCI Industrial
Computers Manufacturers Group.“PCIe” and “PCI EXPRESS” are registered trademarks and/or service marks of PC-SIG. Microsoft, Windows, Visual Studio, Visual
C++, Visual C#, and Visual Basic are either registered trademark or trademarks of
Microsoft Corporation in the United States and/or other countries.
Product specifications and descriptions in this document subject
to change without notice.
© Agilent Technologies, Inc. 2012
Printed in USA, December 13, 2012
5990-6584EN
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising