Get Data from an EtherNet/IP Scanner into your Ethernet
TCP/IP Devices
 Perfect for Devices that
The 460ESTCP allows you to move ASCII data inside TCP/IP packets to an EtherNet/IP PLC.
It’s a simple solution that allows you to pass TCP socket connections data to an EtherNet/IP
PLC. It allows you to interrupt the ASCII data strings into meaningful data types for use in your
PLC.
Output Ethernet TCP/IP
Data
 Support for up to 10
Ethernet TCP/IP
Devices
Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.
How Do You Map the Data?
 Support for Up to 10
EtherNet/IP Listening
Scanners and 1 Scanner
Capable of Reading and
Writing I/O
 Automatically add or
remove delimiters from
your ASCII messages
 Parse your Ethernet
TCP/IP data in up to 50
segments by delimiter or
offset
 Effortless Browser
Based Configuration, no
programming software is
required
 Simple data translation
allows you to manipulate
data as it passes
between protocols
Up to 480 bytes of data can be mapped in each direction between EtherNet/IP and up to 10
Ethernet TCP/IP devices. Data coming from the TCP/IP device(s) can be parsed into up to 50
segments. Each segment can be assigned a data type and delivered to a userdfined data
location on EtherNet/IP. Data location on EtherNet/IP can be concatenated into a single string
of data and deliver to your TCP/IP device.
It’s really that simple. Need to modify your data as it passes from one protocol to the other?
No problem. Each data mapping you apply can be modified with up to 3 mathematic functions.
Add 4 to a value, multiply by 4 and divide by 10 with ease.
Why use Real Time Automation as a Gateway Supplier?
The 460ESTCP provides an option to access Ethernet TCP/IP devices with our EtherNet/IP
PLC. While there are certainly a number of other companies offering stand alone gateways,
there is no one who provides the level of support and service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get honest
answers and recommendations even if that means recommending someone else's solution.
When you get support, it is from an engineer who had a hand in the product’s development,
and support doesn't require a ticket or 24 hour wait. We are unashamed of the fact that we are
a smaller company because that means you mean a lot more to us.
Try the RTA difference today and give us a call at 1-800-249-1612 or check out more
information on us and our other solutions at www.rtaautomation.com.
A Word from our Founder
“It’s likely that your business isn’t industrial networking and it shouldn’t be. You make products, design systems, or manage some process. Whatever it
is that you make, monitor or install the process inevitably creates data. If you’re a control engineer and your plant has been around for a few years your
line is probably littered with devices that send out all kinds of data over many different protocols. If you’re an automation device developer you probably
have customers that need to move your data into some other network. Either way, you’ve got a device conversion problem. You have devices that generate ASCII, Modbus TCP/IP, Modbus TCP, BACnet, Profinet, Profibus, Ethernet TCP/IP, Ethernet/IP, DeviceNet or some other completely proprietary
data and now you’re the person that has to move that data to some other network!
I feel your pain… and rather than just my sympathy, I have a solution for you. You see, while your business may not be moving data around a factory
floor mine is. In fact, it’s all that we have done for over twenty years now. Our 460 series of Device Converters is the culmination of those twenty years.
You can now move all of your data, where you want, when you want and how you want. Try us on your next project, I guarantee you won’t regret it.
John Rinaldi
460ESTCP
www.rtaautomation.com
ETHERNET/IP FEATURES
Operation Modes
Class 1 I/O Adapter
Message Support
Implicit Class 1 Cyclic I/O, Explicit Class 3 and UCMM Supported
Data Types
BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double
Maximum EtherNet/IP Scanner Devices
Up to 10 can listen, only 1 can write I/O
Maximum Data Supported
Up to 480 bytes in each direction
ETHERNET TCP/IP DEVICE FEATURES
Operation Modes
Client or Server
Maximum Number of Devices Supported
10
Maximum Number of Characters Transferred
1024
Delimiter Processing
Incoming delimiters can be automatically removed; Outgoing delimiters automatically added if configured
Parsing
Parse String of ASCII Data in up to 50 Segments by Delimiter or Offset
Concatenation
Concatenate up to 50 segments/strings of ASCII data with optional delimiter
INCLUDED WITH GATEWAY
120 volt AC wall wart power supply
Manual
6’ power cable with flying leads
5 year hardware warranty
IPSetup software — automatically locates RTA gateway on the network
Unlimited firmware feature upgrades for life
CAT5 crossover cable for direct connection to PC during programming
Complete, unlimited access to our industry leading support staff
ELECTRICAL/ENVIRONMENTAL
DC Input Voltage
8 VDC @ 230 mA to 28 VDC @ 80 mA
Maximum Baud Rate
115K baud
Operating Temperature
-40 C to 85 C
Certification
RoHS-Compliant, UL, CUL, CE Approvals, Class I Div 2
DIMENSIONS
ENCLOSURE / HARDWARE
Size
4.2” x 3.25” x 1”
Weight
5 oz.
Enclosure Type
Anodized aluminum
Mounting
Din rail or panel mount
LEDs
Ethernet link/data LED, Ethernet speed LED, power LED, &
2 general purpose LEDS on side.
GATWAY FEATURES & FUNCTIONS
Gateway Security
You can configure up to 9 different users access to
diagnostic and configuration screens.
Alarming
Set <, <=, >=, >, ==, !=, and change-of-state rules on
any data moving through the gateway. If alarm rule is
triggered an email notification can be sent.
Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur
in the gateway.
Status and
Counters
Protocol specific status, counters and error messages
are accessible within the gateways diagnostics page.
They can also be delivered to a connected device.
Diagnostic Logging
Page
Allows users to see and log start up sequences, protocol specific messages & error messages.
NOT EXACTLY WHAT YOU WERE LOOKING FOR?
Real Time Automation offers a full line of gateway products. If this isn’t the one
you were looking for give us a call at1-800-249-1612 or check out a listing at
www.rtaautomation.com/products. We also offer custom gateways to help customers dealing with unique needs or proprietary protocols.
CATALOG #
DESCRIPTION
460ESTCP
EtherNet/IP Scanner to Ethernet TCP/IP Device Gateway
For More Information:
1-800-249-1612
[email protected]
.
www.rtaautomation.com
2014 Copyright Real Time Automation. All rights reserved. The Real Time Automation logo is a registered trademark of Real Time Automation Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement