FEATURES TYPICAL SPECIFICATIONS

FEATURES TYPICAL SPECIFICATIONS
new
product
Type:
Project/Location:
LH SERIES
Contractor:
Prepared By:
Pictogram Sign, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
FEATURES
Date:
Model No.:
TYPICAL SPECIFICATIONS
∙∙ Includes the addition of Class II Div. 1&2 Groups E, F and G as well as Class III ratings
∙∙ Compliant Class I Division 2, Groups A, B, C and D as per
CSA C22.2 No.137-M1981
∙∙ Temperature Code T6 (maximum + 85°C) as per Canadian Electrical Code,
Part I and CSA C22.2 No.137-M1981
∙∙ High-impact thermoplastic frame with built-in gasket to secure against liquid leaks
∙∙ Sealed, polycarbonate heavy-duty, vandal-resistant face plate(s)
∙∙ Concealed pilot light and test switch with magnetic action
∙∙ Long-life white LED light source
∙∙ Supplied standard with two pictogram films per face, for direction selection
∙∙ Meets or exceeds CSA 22.2 No.141-10 standard for pictogram Exit Signs
∙∙ Universal AC input: two-wire 120 to 347VAC; standard DC input: two-wire
6 to 24VDC
∙∙ Energy efficient – consumes less than 2.5W in AC or DC-remote mode
∙∙ Self-powered models come standard with auto-diagnostic functions
and deliver two hours of back-up legend illumination
∙∙ Suitable for cold-weather: -40°C for AC/DC and -20°C for Self-powered
models (option: -CW)
Supply and install the Lumacell® LH Series of pictogram Exit Signs. The equipment
shall be certified for Hazardous Locations: Class I Division 2 Groups A, B, C and D, Class
II Divison 1&2 Groups E, F and G as well as Class III, with the temperature code T6
(maximum 85ºC). The equipment frame shall be of industrial grade polyvinyl chloride
with a gasket around lenses and canopy. The faceplate(s) shall be constructed of
heavy-duty vandal-resistant polycarbonate and feature an even illuminated pictogram
legend. Each face plate shall come standard with two legend films for pictogram and
direction selection. The light source shall be long-life white light-emitting diodes (LED).
The pictogram Exit Sign shall operate with universal 2-wire AC input voltage of 120 to
347VAC at less than 2.5W and universal 2-wire DC input voltage from 6 to 24VDC at
less than 1W for single and double face signs. The Self-powered model shall include
a concealed pilot light and magnet sensitive test switch, shall use a sealed NickelCadmium battery of 2.4V nominal voltage and shall stay illuminated during emergency
operation for at least two hours upon AC failure. The Self-powered model shall include
auto-test functions: it shall execute automatic tests for 5 minutes every 30 days, 30
minutes every 60 days and two hours annually. When a fault is detected, the bi-colour
pilot light shall turn from green to red and flash following a particular code. The code
description shall be visible on a label next to the pilot light to identify the failure type:
battery, charger circuitry, or LED lamps. The pictogram Exit Sign shall meet or exceed
the CSA 22.2 No.141-10 standard.
The equipment shall be Lumacell® Model: _________________________ .
Made in Canada
HAZARDOUS LOCATION FAMILY CLASS I, II AND III
3LER-HZ Combo
LER-HZ
LHC Combo
RG-HZ Battery
MQM-HZ Remote
POWER CONSUMPTION
MODEL
56
AC SPECS
DC SPECS
AC-only
120 to 347VAC
less than 2.5W
-
-
AC/DC standard
120 to 347VAC
less than 2.5W
6 to 24VDC
less than 1W
AC/Special DC
120 to 347VAC
less than 2.5W
36, 48, 120VDC
less than 2.5W
two-wire 120V AC/DC
120VAC
less than 2.5W
120VDC
less than 2.5W
self-diagnostic
120/347VAC
less than 2.5W
nickel-cadmium battery
min. two hours
www.lumacell.com
new
product
Type:
Project/Location:
LH SERIES
Contractor:
Prepared By:
Pictogram Sign, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
Date:
Model No.:
DIMENSIONS
Dimensions are approximate and subject to change.
4-3/8“ [11.1 cm]
4-1/4” [11.0 cm]
9-1/4” [23.4 cm]
< PICTOGRAM
LEFT FROM HERE
2-1/4” [5.7 cm]
PICTOGRAM
STRAIGHT FROM
HERE
13-1/4” [33.6 cm]
PICTOGRAM >
RIGHT FROM HERE
3-1/2” [8.9 cm]
ORDERING INFORMATION
SERIES
LH= CL.I Div.2
pictogram
FACES*
1= single face
2= double face
HOUSING
COLOUR
G= grey
VOLTAGE
SD= self-powered diagnostic NiCad, 120/347VAC
SD2= self-powered diagnostic NiCad, 120/277VAC
U= universal 120 to 347VAC; 6 to 24VDC
U00= 120 to 347VAC only
U36= 120 to 347VAC; 36VDC
U48= 120 to 347VAC; 48VDC
U120= 120 to 347VAC; 120VDC
2120= 2-wires 120VAC/VDC
NEX= NEXUS® system interface, 120/347VAC
NEX2= NEXUS® system interface, 120/277VAC
NEXRF= NEXUS® system interface, 120/347VAC
NEXRF2= NEXUS® system interface, 120/277VAC
OPTIONS
CW= cold-weather (-20°C for
self-powered and NEXUS®)
]
*Ceiling or wall mount only.
*Not all options available with NEXUS® System.
Please consult your sales representative
*-40oC comes standard with AC/DC
EXAMPLE: LH1GU
www.lumacell.com
57