Farmscan 2200 RFM Monitor Installation and Operating Instructions
The 2200 RFM Monitor is a versatile tool designed for monitoring various machinery functions, including speed, area, distance, and custom sensor readings via five dedicated ports. This manual provides comprehensive instructions on installing, operating and calibrating the monitor to ensure optimal functionality.
Advertisement
Advertisement
RFM 2200
2200 RFM Monitor
INSTALLATION AND
OPERATING INSTRUCTIONS
HIGH PRESSURE VERSION 3.0x
LOW PRESSURE VERSION 3.0y
Part No:AM-2200/5
2200 RFM monitor
CONTENTS
STANDARD AND OPTIONAL PART LIST
1.0 INSTALLATION
2
1
REMOTE HOLD
2.0 OPERATION
ON KEY 10
2.7 TOTAL KEY 12
TRIP KEY 14
3.0 CALIBRATION
REMOTE CALIBRATION 32
4.0
TROUBLESHOOTING
5.0
INTERFERENCE AND REMEDIES
SENSOR / PORT COMPATIBILITY CHART
34
37
38
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor
PARTS LIST
REF PART NO. DESCRIPTION
5
6
7
1
2
A-2200/4RFM
A-2403RFM
RFM RICEMASTER MONITOR
RFM RICEMASTER CONTROLLER
3 AC-M6001-I IMPLEMENT
4 AC-M6001-T TRACTOR CABLE RFM RICEMASTER
AA-118
AA-110P
AA-112P
FLAT GREY MAGNET
REED TYPE SENSOR (PACKARD)
COIL TYPE SENSOR (PACKARD)
SECURING KNOB ¼” 8 AH-861
9 AH-406
10 AH-415
11 AC-101F
12
13
AA-105
AM-200
MOUNTING BRACKET – METAL
8m LIGHT DUTY POWER CABLE FUSED
MAGNET (PULLEY MOUNT) 10mm x 15mm
FARMSCAN 2YR WARRANTY CARD
OPTIONS PARTS LIST
PART NO. DESCRIPTION OF KIT
2076
2077
2060
2201
AC-205
AC-210
AC-305
AC-310
AP-105
AP-106
2002
2004
WHEEL SENSOR KIT
RADAR SPEED SENSOR KIT
2004A RADAR KIT
2007 SPEEDO CABLE SENSOR KIT
2008
2009
2030
2050
PROXIMITY SENSOR SHAFT
TAILSHAFT SENSOR KIT
FLOW SENSOR KIT
FLOW SENSOR KIT
2015
2025
2070
2080
2034
PRESSURE SENSOR KIT
PRESSURE SENSOR KIT
ENGINE WATER TEMP SENSOR KIT
AIR PRESSURE SENSOR KIT
PULLEY SENSOR KIT
SHAFT SENSOR KIT
SHAFT SENSOR KIT
BIN / TANK LEVEL SENSOR KIT
10M EXTENDED W/PROOF JUNCTION KIT
2 WAY 5m
2 WAY 10m
3 WAY 5m
3 WAY 10m
12 WAY
12 WAY
(1 - 50 KPH)
(1 - 49 KPH)
(1 - 100 KPH)
(1 - 9999 RPM)
(1 - 1500 RPM)
(8 - 200 L/MIN)
(50 - 500 L/MIN)
(0 - 500 KPA)
(0 - 2500 KPA)
(40 - 120° C)
(0-25 KPA)
(50 - 9999 RPM)
(1 - 1500 RPM)
(50 - 9999 RPM)
SENSOR CABLE EXTENSION
SENSOR CABLE EXTENSION
SENSOR CABLE EXTENSION
SENSOR CABLE EXTENTION
BREAKAWAY PLUG
BREAKAWAY SOCKET
QTY
1
1
2
1
1
1
1
8
1
2
1
1
1
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2
2200 RFM monitor: OPERATION
1.0 INSTALLATION
The RFM MONITOR should be installed in the cab, clearly visible to the operator but not subject to intense heat or moisture.
Keep the unit away from radios or other electronic equipment to minimize any risk of interference.
As a precaution all connection cables should take an alternative route to other cables it the cab; especially antennae cables or clutch, solenoid and engine kill switch cables.
Mount the unit firmly on the bracket using securing knobs supplied. Don't use substitute bolts into the unit.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
3
2200 RFM monitor: OPERATION
4
Do not connect power until all other installation is complete.
The 8 metre power cable must be connected direct to 12 volt DC vehicle battery terminals.
DO NOT join power cable with any other electrical equipment or the vehicle chassis, this may cause interference.
USE cable ties supplied to secure power cable away from risk of damage.
Connection to battery terminals must be clean and tight.
WARNING - Remove green connector plug at rear of monitor if arc welding on machinery.
TYPICAL BATTERY HOOK-UPS
NEG
POS
RED
BLACK
NEG
CONNECTION
DETAIL
NEG
POS
RED
BLACK
POS
RED
BLACK
NEG
VEHICLE
GROUND
NEG
POS 24V
POS 12V
ONE 12 VOLT BATTERY TWO 6 VOLT BATTERIES TWO 12 VOLT BATTERIES
Connect power cable to pins 10 & 11 of green connector plug as shown on next page.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
1.3 SENSOR CONNECTIONS AND WIRING
All Farmscan sensor wires have a common colour code system.
WHITE = SIGNAL
5
Some sensors such as wheel sensors and shaft sensors only have two wires (signal and ground).
Other sensors that require +12 volts as well as signal and ground will have 3 wires, such as flow sensors, bin level sensors and radar speed sensors.
Look at the back panel of the RFM MONITOR you will see that PORTS 1 - 5 and the wheel input connections are marked to accept the white signal wire from the relevant sensor.
The black wires (common) from each sensor can be connected together and shared between pins
7 or 9. e.g. In the drawing the wheel sensor is connected to Pin 6 (white) and Pin7 (black)
2200 RFM
If a flow sensor with 3 wires was connected to Port 5, the connection would be as follows:
WHITE WIRE TO PIN 5 (PORT 5 SIGNAL)
BLACK WIRE
RED WIRE
TO PIN 9 (COMMON)
TO PIN 8 (+12 V OUT)
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
6
Each sensor is supplied with a 5 metre length of 2 way or 3 way cable with weatherproof sealed connector at the sensor end. A bracket and clip is supplied to mount the connector at the rear of a tractor if using the cable as a breakaway implement connection.
If using cables as an implement breakaway, be sure to join the dust plugs when the implement connection is in use.
Extension cables are available in 5 or 10 metre lengths with matching connectors and dust caps.
OPTIONAL EXTENSION CABLES
AC - 205
AC - 210
2 WAY / 5 METRE EXTENSION CABLE
2 WAY / 10 METRE EXTENSION CABLE
AC - 305 3 WAY / 5 METRE EXTENSION CABLE
AC - 310 3 WAY / 10 METRE EXTENSION CABLE
When multiple sensors are used on an implement, the 2201 10 metre “EXTENDED JUNCTION
BOX” is a simple solution that provides all the rear panel connections in a remote weatherproof junction box.
A Breakaway plug and socket should be ordered separately if the junction box is fitted onto an implement.
Order: AP-105
AP-106
12 Way Brylite Plug
12 Way Brylite Socket
Use the 5 metre cables supplied with each sensor to join into the junction box connectors.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
The standard wheel sensor supplied with the surveillance kit, consists of a sensor and magnet to be fitted onto any undriven ground wheel.
Install the wheel sensor on an undriven front tractor wheel or onto a trailed implement wheel using one of the optional 2 way extension cables or the 2201 extended junction kit.
Alternatively, if the wheel sensor is not practical you can choose from any of the optional speed sensing kits explained in section 3.3.
WHEEL SENSOR INSTALLATION PROCEDURE
Bolt the wheel magnet onto the wheel in a position that allows it to sweep directly past the wheel sensor within 15 - 20 mm once every rotation.
The magnet can be mounted anywhere in a radius from centre of the wheel. Near the hub will ensure the best ground clearance.
The sensor must be rigidly bolted to an existing structure, ideally in a protected position.
If mounting the sensor on a steered wheel, make sure the sensor moves with the steering mechanism to maintain equal clearance between the magnet and sensor when turning from lock to lock.
Connect sensor to cable supplied and use cable ties to secure cable away from potential damage.
Allow enough slack for axle movement and steering.
Connect wheel sensor to plug at rear of surveillance monitor.
WHITE WIRE TO WHEEL PIN 6
BLACK WIRE
Snip off unnecessary dust plugs.
TO GROUND PIN 7
NOTES :
Four different magnet mounting ideas.
1) Drill through wheel rim and bolt magnet on.
2) Braze magnet nut onto rim and screw magnet into nut.
3) Cut thread off magnet and araldite magnet to rim.
4) Knock out a wheel stud and make up a piece of flat bar with suitable holes each end.
5) Bolt the magnet to one end and secure the flat bar under the wheel stud adjusted to the required position.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
7
2200 RFM monitor: OPERATION
8
1.6 SPLIT WIDTH LINKING INSTALLATION
The RFM MONITOR is able to accept up to three separate width calibrations for left, centre and right boom operation by making a connection from existing controlling switches to the RFM
MONITOR.
To make the connection work, your existing boom control switch panel must be operating from the same 12 volt DC source as your RFM MONITOR.
Simply run a separate single core wire from signal Ports 1, 2 & 3 (white) of the RFM MONITOR to each of the respective left, centre and right controlling switches on your boom control panel.
Connect the linking wire to the switched terminal that becomes live (+ 12 V) when the boom solenoid is open (operating).
IMPORTANT :
Whichever Ports 1, 2 or 3 are used must be enabled for split width calibration (see Section 3.4).
The solenoid valves must be physically connected to enable ‘SPLIT WIDTH CALIBRATION’. If the solenoid valves become disconnected, then ‘SPLIT WIDTH CALIBRATION’ will not function.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
Issue 1.30
2200 RFM monitor: OPERATION
9
1.7 REMOTE RUN / HOLD INSTALLATION
The RUN / HOLD function may be activated or deactivated by making or breaking an electrical connection from Pin 12 of the RFM MONITOR to any existing 12 - 13.8 V DC electrical device that is switched on or off whenever the machine is engaged (working).
NOTE :
If using split width linking, it is not necessary to connect the remote run / hold function, because the monitor will go on hold when all widths are off.
The wire connected from run / hold Pin 12 must make connection to ground (negative) either when the machine is engaged or when the machine is disengaged.
The switch and monitor must be all on the same 12 Volt source.
Use a multimeter or testlight to find a contact point that is switched to ground when your implement is engaged or disengaged.
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
2.0 OPERATION
10
The 2200 RFM MONITOR is designed to provide a complete range of machinery monitoring functions in one unit.
The basic monitor provides speed, area and distance readouts with connection of a wheel sensor supplied in the kit.
Up to five additional machinery functions can be monitored by connecting appropriate sensors into the five spare ports of the RFM MONITOR (Ports 1 - 5).
Each Port can be set to accept any one of a variety of different sensor functions.
(See “PORT / SENSOR COMPATIBILITY” CHART - Page 4).
This means you can fit different sensors to various machines and simply change the setting of each
Port to suit the type of sensor installed.
When the RFM MONITOR is supplied standard on a new machine, refer to separate instructions to find which sensor options are installed on the machine and which ports will need to be activated
(enabled).
An inbuilt memory backup system will hold all calibration and accumulated totals in memory for at least 1 month after disconnection from the 12 Volt DC power source.
2.3 POWER ON / OFF KEY
Whenever the monitor is switched on the display screen will firstly confirm which software program is installed. e.g.
SURVEILLANCE
The version number immediately follows this: e.g.
VERSION 3.0y
The version number relates to the functions and features programmed into your unit.
If ever an upgraded program is installed, a new version number e.g. “VERSION 3.0y” will be displayed.
The readout will always display the speed readout after switching on. e.g.
SPEED 0.0 KPH
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
11
If any alarm points are active when the monitor is switched on, press the “RUN / HOLD” key to silence the beeper.
2.4 IMPERIAL / METRIC KEY
Press the “IMP / MET” key to change any readout between metric and imperial equivalents. e.g.
SPEED 10.0 MPH
IMPERIAL IS ‘UK IMPERIAL’
SPEED 16.0 KPH
NOTE : “IMP / MET” key is not active during calibration. These must be entered in metric values.
2.5 RUN / HOLD KEY
The “RUN / HOLD” key has dual functions, press it once to place the ‘MONITOR ON HOLD’. e.g.
MONITOR ON HOLD
Press “RUN / HOLD” again to place the ’MONITOR OFF HOLD’ e.g.
MONITOR OFF HOLD
When in ‘HOLD’ mode, all alarms and accumulating readouts such as “AREA”, “DISTANCE” and the “ELAPSED TIMER” are stopped.
The monitor will repeat the monitor on hold warning every 30 seconds to remind the operator everything is on hold.
REMOTE RUN / HOLD
As an alternative to manually activating the “RUN / HOLD” key you can automatically place the monitor on hold by connecting a wire from the rear panel of the surveillance monitor to any electrical device (e.g. clutch switch) that is activated whenever the machine is operational. See
Section 1.7 for connection details.
2.6 SPEED KEY
Press the “SPEED” key once to display ground speed e.g.
SPEED 14.6 KPH
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
Press the “SPEED” key again to display current work rate expressed as “HECTARES PER HOUR”. e.g.
AREA 43.2 HA / H
12
AREA TOTAL
Press “TOTAL” key once to display “TOTAL AREA” worked. e.g.
TOTAL 2750 HA
The area total can be reset at the start of a sowing / harvesting season and left to accumulate daily to keep track of overall areas worked.
To reset “AREA TOTAL” press “RESET” key once to start reset process. e.g.
RESET TOTAL ?
Press “RESET” again to complete reset process or to abort reset process, press any other key to escape.
After reset of “TOTAL” you will have the option to reset all trip memories at the same time e.g.
RESET ALL TRIPS ?
Press “RESET” again to reset all trips or to abort reset process, press any other key to escape.
DISTANCE TOTAL
Press “TOTAL” key again to display “TOTAL DISTANCE”. e.g.
DISTANCE 45.65 KM
To reset “DISTANCE” press “RESET” key once to start reset process. e.g.
RESET DISTANCE ?
Press “RESET” again to complete reset process or to abort reset process, press any other key to escape.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
13
DISTANCE ALARM
Press “TOTAL” key again to display “DISTANCE ALARM” e.g.
DIST ALM 00.000 M
centimetres
metres
100s of metres
kilometers
The distance meter can have an alarm point set to give an audible beep at set distance intervals e.g. For post hole positions or plotting a laser levelling grid map.
NOTE : High accuracy plotting points require small wheel sensor pulse intervals available with speedo cable, tailshaft or radar ground speed sensor options.
1000 METRES = 1 KILOMETRE
Use ‘UP’ or ‘DOWN’ key to set “DISTANCE ALARM” point. e.g.
DISTANCE ALM 0.030M
ie : every 30 metres
To start the distance alarm select “DISTANCE” and press “RESET” to zero “DISTANCE” at starting point. e.g.
DISTANCE 0.000KM
To cancel the distance alarm select “DIST ALM” then press “RESET” key to zero distance alarm. e.g.
DIST ALM 0.000M
To stop or start “TOTAL AREA” and “DISTANCE” meter press “RUN/HOLD” key (this can be remotely activated see Section 2.5).
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
14
2.8 TRIP AREA KEY
The “TRIP AREA” key allows the display of the sub total area for each separate plot of land worked.
The “TRIP AREA” function has 10 resetable memories to keep record of areas worked in different plots.
To display the current trip memory press “TRIP AREA” key. e.g.
TRIP 1 56.2 HA
Trip 1 may be reset to zero at any time or kept as a record by changing to Trip 2, as explained below.
To reset trip memory press “RESET” key to “START” reset process. e.g.
RESET TRIP 1 ?
Press “RESET” key again to complete reset process. e.g.
TRIP 1 0.00 HA
To change current trip memory press ‘UP’ or ‘DOWN’ key to change current trip number on display. e.g.
TRIP 2 0.00 HA
NOTE :
Trip records can be viewed or reactivated by using the ‘UP’ and ‘DOWN’ keys to change the current trip memory. Whichever trip number is displayed will be active when working.
LOAD AREA
Load area is a separate area meter that can be reset after every bin or tank refill to check coverage rates.
Press “TRIP AREA” key again to display “LOAD AREA”. e.g.
LOAD 14.5HA
To reset load area press “RESET” key once to instantly reset load area total. e.g.
LOAD 0.00HA
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
15
LOAD ALARM
A ‘LOAD AREA’ alarm point may be set to alert the operator when a bin should be full or empty after completing a set amount of area. e.g. The seeder box will have one round left at 26.0 HA.
To set load alarm press “TRIP AREA” key again to display “LOAD ALARM”. e.g.
LOAD ALM 0.0 HA
Use ‘UP’ and ‘DOWN’ keys to set the load area alarm point. e.g.
LOAD ALM 26.0 HA
To start load alarm press “TRIP AREA” key to select “LOAD AREA” then reset load area total after refilling bin / tank.
To cancel load alarm press “TRIP AREA” key to select “LOAD ALARM” then reset load alarm to zero.
NOTE :
“RUN / HOLD” key or remote “RUN / HOLD” will start / stop trip area and load area meters to keep the tally right.
2.9 TIMER KEY
The “TIMER” key allows display of the “ELAPSED TIME” of machine operation.
The ‘ELAPSED’ timer can be reset to zero at any point. The “RUN / HOLD” key will stop / start the elapsed timer.
If required the ‘ELAPSED’ timer may be programmed with an elapsed time alarm point which can serve as a warning of a due maintenance interval.
Press the “TIMER” key to display the elapsed timer. eg ELAPSED 00:00
Ð:Ð
To reset elapsed timer press the “RESET” key.
TIMER ALARM
An elapsed time alarm may be set to activate after the “ELAPSED” display counts up to a set point.
To set timer alarm press “TIMER” key again to display “SET TIMER”.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
Use ‘UP’ and ‘DOWN’ key to set duration of time to elapse before alarm will activate. eg SET TIMER 00:00
•••••
16
To start timer press “TIMER” key to display “ELAPSED TIME” then press “RESET” to start timer counting up from zero.
To cancel timer press “TIMER” key to display “SET TIMER” then press “RESET” to zero, timer alarm.
2.10 FUNCTION KEY
The “FUNCTION” key will display in sequence whichever optional functions have been enabled for
“PORTS 1 – 5” in the calibration cycle.
Refer to the “SENSOR COMPATIBILITY CHART” to make sure the correct sensor is connected to the correct port for the required function.
NOTE :
The ports must be enabled before the “FUNCTION” key will operate.
See Section 3.4.
If no ports are enabled, then the “FUNCTION” key has no function when pressed. e.g.
NO PORTS ENABLED
If for example ‘PORT 1’ is enabled for “SHAFT 1”, then the “FUNCTION” key would display the activity for ‘SHAFT 1’ when pressed. e.g.
SHAFT 1 750 RPM
If ‘PORT 2’ was also enabled as ‘SHAFT 2’, then the “FUNCTION” key would display the current status of “SHAFT 2” when pressed a second time. e.g.
SHAFT 2 STOPPED
Some functions such as “FLOW” on ‘PORT 5’ have multiple displays when you press the
“FUNCTION” key in succession. e.g.
RATE 55.0 L / HA
VOL USED 1250 L
FLOW / MIN 22.5 LPM
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
17
Some function displays such as “VOL USED” can be reset when you refill the tank. e.g.
VOL USED 0.0 L
Press “RESET” key to reset “VOL USED” display.
FUNCTION DISPLAYS AND ALARMS EXPLAINED
Before the “FUNCTION” key will operate the required function must be enabled for each port 1 - 5
- see Calibration Section 3.4.
SHAFT MONITORING (PORTS 1-5)
Press the “FUNCTION” key to display the RPM of whichever shafts 1 - 5 have been enabled - see
Calibration Section 3.4.
The working range is 1 - 9999 RPM, depending on sensor type and capability e.g.
SHAFT 1 750 RPM
Below 1 RPM the display would show “SHAFT STOPPED”. e.g.
SHAFT 1 STOPPED
SHAFT ALARMS
There are three possible alarm choices for each of the Shafts 1 - 5
Refer to calibration details Section 2.5 to set your choice.
1. “SHAFT BELOW RPM” - Alarms at 5 second intervals immediately the RPM falls below the
‘LO ALARM POINT’ set for that shaft. e.g.
SHAFT 1 LO 700
2. “SHAFT ABOVE RPM” - Alarms at 5 second intervals immediately the RPM rises above the
RPM ‘HI ALARM POINT’. e.g.
SHAFT 1 HI 800
3. “SHAFT STOPPED ALARM” - activates if any of the shafts 1 - 5 are not active for more than
5 seconds. e.g.
SHAFT 1 STOPPED
NOTE :
If no alarm point has been set for either “HI” or “LO” then the monitor will display whichever shaft has stopped but will not sound an alarm.
For alarm points under 10 RPM the waiting time is extended before the ‘SHAFT
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
18
STOPPED’ alarm is activated.
Press the “RUN / HOLD” key to silence the shaft alarm when the machine has stopped.
BIN / TANK LEVEL MONITORING (PORTS 1 & 2).
The 2060 Bin / Tank sensors can be set to activate a warning for full or empty (low) bin conditions - refer to Calibration Section 3.4 and 3.5.
For full bin operation, the sensor is mounted at a point towards the top of the bin.
For low bin operation the sensor is mounted towards the bottom of the bin.
When the “FUNCTION” key is pressed you can display the current status of each bin sensor. e.g.
BIN 1 FULL
or
BIN 1 OK
or
BIN 2 LOW
Whenever a sensor changes from “OK” to “FULL” or “LOW” the alarm will sound and the relevant warning will be displayed - the alarm will repeat at 45 second intervals to remind the operator.
COUNTER FUNCTION (PORT 3)
The “COUNTER” function allows a tally of events activated by any switch operation.
Refer to Calibration Section 3.4.
For example, this may be the counting of bales expelled from a baler, or shaft rotations of an Auger feeding out grain to livestock.
You can use any sensor or switch that suits the application.
Press the “FUNCTION” key to display the counter operation. e.g.
COUNTER 0
Press the “RESET” key to zero the counter.
If required, a counter alarm point may be set to activate at a set number - refer to calibration
Section 3.5. e.g.
COUNT ALM 60
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
PRESSURE FUNCTION (PORT 4)
The ‘PRESSURE’ function is suitable for spray line pressure measurement or airseeder air pressure.
There are two types of pressure sensor available for sprayline pressure and one for fan pressure measurement.
Sprayline Pressure Measurement
2015 PRESSURE SENSOR
2025 PRESSURE SENSOR
Fan Pressure Measurement
2080 AIR PRESSURE SENSOR
( 0 - 500 KPA )
( 0 - 2500 KPA )
( 0 - 25 KPA )
NOTE : There are two versions of the 2200 RFMMonitor available for higher or lower pressure requirements.
VERSION 3.0x
is used in conjunction with the 2015 and 2025 pressure sensors for higher pressure requirements. e.g.
VERSION 3.0y
is used in conjunction with the 2015 and 2080 pressure sensors for lower pressure requirements.
Refer to calibration section 3.4 to enable the correct type of sensor.
Press the “FUNCTION” key to display the pressure.
PRESSURE 320 KPA
NOTE :
It is normal to have a residual reading of 5 - 10 KPA with no pressure on air pressure sensors. Sprayline pressure sensors have a residual reading of 1 - 2 KPA on airseeder.
If required you may set ‘HI’ or ‘LO’ pressure alarm points. Refer to Calibration Section 3.5. e.g.
PRESSURE HI 450
OR
PRESSURE LO 120
TEMP FUNCTION (PORT 4)
The “2070 ENGINE TEMP SENSOR” is a radiator water / engine temperature sensor that will give a readout of temperature in the range 40
° - 120 ° Centigrade. Refer to Calibration Section 2.5.
A ‘HI TEMP ALARM POINT’ may be set as a warning of increased water temperature.
19
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
NOTE :
Loss of radiator water will not necessarily cause the “HI TEMP ALARM” to activate due to lack of heat contact.
Refer to Calibration Section 3.5 for details.
For temp operation press the “FUNCTION” key to display “TEMPERATURE”. e.g.
TEMPERATURE 90°C
Temp Alarm: The “HI TEMP” warning will activate as a priority alarm regardless of any other function selected if the temperature exceeds the alarm point. e.g.
TEMP HI 108°C
The “RUN / HOLD” will not silence the temperature alarm.
FLOW FUNCTION (PORT 5)
When the ‘FLOW’ function is enabled for Port 5, the application rate, volume used and flow rate will be displayed when the “FUNCTION” key is pressed in succession. Refer to Calibration Section
3.4.
An alarm may be set for low tank and excessive rate variation.
There are two sizes of flow sensor kit available to suit different flow rates and pressures.
1. 2030 1" FLOW SENSOR KIT ( 8 - 200 L / MIN )
MAXIMUM PRESSURE - 1000 PSI (6896 KPA)
2. 2050 2" FLOW SENSOR KIT ( 50 - 500 L / MIN )
MAXIMUM PRESSURE - 145 PSI (1000 KPA)
Alternative flow sensors may also be compatible - refer to Computronics with details.
FLOW OPERATION
To maintain accurate rate and volume readings, the correct width, wheel and flow sensor, calibrations must be set - refer to Section 3.4.
Press the “FUNCTION” key to display “APPLICATION RATE”. e.g.
RATE 75.1 L / HA
Press “IMP / MET” key to convert to “GALLONS PER ACRE”. e.g.
RATE 6.8 G / AC
NOTE :
If using split width calibration, the rate reading will alter when different boom sections are activated. Refer to Section 3.2 for split width calibration.
20
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
21
Press “FUNCTION” key again to display accumulated volume. e.g.
VOL USED 1540 L
Press the reset key to zero volume used after refilling the tank. e.g.
VOL USED 0 L
Press “FUNCTION” key again to display flow rate. e.g.
FLOW/MIN 32.1 LPM
FLOW ALARMS
Based on entering the tank capacity as a calibration factor, the monitor will give an alarm when all but 100 litres of the total has been sprayed. e.g.
TANK 100 L LEFT
For example if the tank holds 2000 litres, then the alarm will activate when the volume used reaches 1900 litres.
Based on entering a target application rate and allowable error percentage as a calibration factor, the monitor will give a “RATE HI” or “LO” alarm.
Refer Calibration Section 3.5.
For example if the target rate is set for “50 L / HA” and the allowable error is set for 10% then the alarm will activate outside these limits. e.g.
RATE HI 58 L / HA
OR
RATE LO 42 L / HA
The alarm may be silenced by pressing “RUN / HOLD” which will also hold the area meter.
If the rate error calibration is set to zero % then the rate of application will be displayed, but there will be no alarm when the rate varies.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
22
FAN MONITORING FUNCTION (PORT 5)
When Port 5 is enabled for “FAN” the “FAN SPEED” is displayed by pressing the “FUNCTION” key.
Refer to calibration Section 3.4. e.g.
If the fan stops then the display will indicate “FAN STOPPED”. e.g.
FAN STOPPED
FAN ALARM
A fan RPM Alarm Point may be set for both over or under RPM - see Calibration Section 3.5.
Fan slow alarm -activates at 5 second intervals immediately the RPM falls below the slow alarm point and repeats at 5 second intervals. e.g.
FAN SLOW 3300
Fan fast alarm - activates at 5 second intervals immediately after the RPM rises above the fast alarm point and repeats at 5 second intervals. e.g.
FAN FAST 3800
NOTE :
Press “RUN / HOLD” to silence the alarm when machinery is not working.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
3.0 CALIBRATION
23
Variable information such as machinery “WIDTH” and “WHEEL” size must be entered into the calibration memory before you can operate the surveillance monitor as a speed / distance / area meter.
If you wish to use any of the various sensor options connected to Ports 1 - 5. You must enable
(activate) each Port for the required function - see Calibration 3.4.
The “CAL” (Calibration) key takes you through a series of set-up questions. Each time you press
“CAL”, the next question will be displayed to the left of the screen. e.g.
Use the ‘UP’ or ‘DOWN’ arrow key to change the calibration factor and press “CAL” again to step onto the next question.
When you use the ‘UP’ / ‘DOWN’ keys, notice the numbers change slowly at first then faster if you continue to hold the key.
The reset key can be used to zero any calibration factors on display.
If you wish to step back to a previous “CAL” option, you must press a function key, eg “SPEED”, to escape the “CAL” routine then start again.
The “WIDTH” calibration is simply a measure of the effective implement width in METRES.
Press “CAL” key to display “WIDTH” and use ‘U’P and ‘DOWN’ keys to set correct width. e.g.
SPLIT WIDTH CALIBRATION (OPTIONAL)
In situtations where the width may be split into two or three sections, for instance a sprayer with left, centre and right boom control you can enter separate left, centre and right widths so that area and rate readouts will be corrected whenever the width of operation changes. This will also act to place the monitor in ‘HOLD’ mode whenever all width switches are turned off.
To enable this possibility (see Installation Section 1.6 Split Width Linking) and (Calibration Section
3.4 Port 1, 2 and 3 left, centre, right widths).
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
24
! IMPORTANT
Split Width calibration procedure will not work unless Ports 1, 2 and / or 3 are enabled for width detection and the appropriate electrical connections are made between the left centre and right controlling switches to Ports 1, 2 & 3.
SPLIT WIDTH CALIBRATION PROCEDURE
1. Turn left, centre and right boom control switches OFF. Turn master boom control switch on.
(Beware of upside down switches on American boom control units.
2. Press “CAL” key to display “WIDTH”. e.g.
WIDTH L 5.40 M
4. Use ‘UP’ / ‘DOWN’ keys to set correct “LEFT WIDTH”.
6. When all widths are set, turn all switches on together to display the overall width e.g.
WIDTH ALL 12.20 M
7. Turn all width switches or master switch off to display “WIDTH OFF”. e.g.
WIDTH OFF 00.00 M
NOTE: split width calibration will not work if sprayer solenoids disconnected from wiring.
The wheel factor is a measurement of distance travelled between pulses from the wheel input sensor.
There are various types of wheel input sensors available, to suit different applications. Choose an appropriate sensor to minimise potential slippage error caused by driven wheels or to get more pulses for slower working speeds.
Suits free rolling tractor or implement wheel with at least one metre rolling circumference or more.
Provides high accuracy, totally independent ground speed monitoring, ideal for 4WD tractors and front assist tractors with linkage implements and slow working speeds.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
3. 2004A RADAR INTERFACE KIT (optional) allows connection to existing tractor ground speed radar sensor.
25
Screws inline with existing speedo drive cable, suits most Japanese 4WD vehicles with
M22 x 1.5 Thread.
Picks up metal objects rotating on shaft e.g. Bolt head or teeth of a sprocket, well suited to high rotation speed or to give multiple pulses on a slow moving shaft.
Suits installation on FIXED tailshaft, utilises magnet on 100mm hoseclamp and switching type sensor. (magnet can be transferred to other size hoseclamps).
Suits installation on drive shaft related to ground wheel drive, provides 32mm hose clamp magnet and switching type sensor.
WHEEL CALCULATION PROCEDURE
1.
2.
If the wheel input sensor is subject to changing tyre load, then half fill tank / bin.
Measurement procedure must be performed in the field, not on a tarmac
(recheck measurement when moving from hard to soft conditions). e.g.
TEST WHEEL 0
4. Creep vehicle forward and watch the counter increment on every sensor pulse.
Stop exactly on a pulse, then press reset key to bring test wheel counter back to zero.
5.
6.
Peg ground at bottom centre of any wheel as a starting reference point for measurement.
Drive forward for approximately 25 metres or more and stop exactly on a pulse update. e.g.
TEST WHEEL 14
7.
8.
Now measure the exact distance travelled and divide the pulses counted into the distance covered. e.g. Distance 25.86 metres
÷ 14 pulses = 1.847 M / PULSE
Now press “CAL” key to display “WHEEL” calibration and use
‘UP’ / ‘DOWN’ keys to enter the correct wheel factor.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
26 e.g.
WHEEL 1.847 M
NOTE: At slow working speeds - under 8 kph additional magnets or another sensing means may be required for optimum response of monitor speed and rate readouts.
Use this formula to check for suitability and if the answer is less than 3 you will require more pulses for a smooth response.
Slowest Working Speed eg
Wheel Factor
4 kph
1.847m
= 2.16
With 2 magnets the result would be acceptable. eg 4 kph
1.847
× ½
= 4.33
3.4 DEFINE PORTS CALIBRATION
After connecting any of the optional sensors to ports 1 - 5 of the MONITOR, you must define (set) which functions are required for each Port.
When you finish defining all the ports continue to press the “CAL” key to display and set any variable information such as alarm points or targets related to the activated functions.
DEFINE PORTS PROCEDURE
1. Press “CAL” key until “DEFINE PORTS” is displayed - the default is always “NO”. e.g.
DEFINE PORTS/NO
(Press CAL key again at the NO prompt to go straight to the alarm Calibrations if you have already enabled the required Ports).
2. Use ‘UP’ key to change from “NO” to “YES”. e.g.
DEFINE PORTS/YES
3. Press “CAL” key again to display “PORT 1” status. e.g.
PORT 1 DISABLED
Use ‘UP’ / ‘DOWN’ keys to select the required function for PORT 1. e.g.
PORT 1 DISABLED
NO FUNCTION
PORT 1 SHAFT 1
SHAFT 1 - 9999 RPM
PORT 1 BIN 1
FULL / EMPTY BIN 1
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
PORT 1 WIDTH L
SPLIT WIDTH (LEFT)
Press “CAL” key to step to “PORT 2” function options.
Use ‘UP’ / ‘DOWN’ keys to select the required function for “PORT 2”.
PORT 2 DISABLED
NO FUNCTION
PORT 2 SHAFT 2
SHAFT 1 - 9999 RPM
PORT 2 BIN 2
FULL / EMPTY BIN 2
PORT 2 WIDTH C
PORT 3 DISABLED
SPLIT WIDTH (CENTRE)
Press “CAL” key to step onto “PORT 3” function options and select the required function.
NO FUNCTION
PORT 3 SHAFT 3
SHAFT 1 - 9999 RPM
PORT 3 COUNTER
EVENTS COUNTER
PORT 3 WIDTH R
PORT 4 DISABLED
SPLIT WIDTH (RIGHT)
Press “CAL” key to step onto “PORT 4” function options and select the required function.
NO FUNCTION
PORT 4 SHAFT 4
SHAFT 1 - 9999 RPM
PORT 4 PRESS 25
PRESSURE SENSOR
0 - 25 KPA (Low Pressure Version 3.0y)
PORT 4 PRESS 500
PRESSURE SENSOR
0 - 500 KPA (Low and High Pressure)
PORT 4 PRESS 2500
PRESSURE SENSOR
0 - 2500 KPA (High Pressure Version 3.0x)
PORT 4 TEMP
TEMP SENSOR 40 - 120
°C
Press “CAL” key to step onto “PORT 5” function options and select the required function.
PORT 5 DISABLED
NO FUNCTION
PORT 5 SHAFT 5
1 - 9999 RPM
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
27
2200 RFM monitor: OPERATION
28
PORT 5 FLOW
FLOW SENSOR
PORT 5 FAN
FAN SPEED
Press “CAL” key again to proceed into “CALIBRATION ALARMS” and “SET POINTS” for the various sensors enabled on Ports 1 - 5.
After defining Ports 1 - 5, continue to press the “CAL” key in succession to step through the various alarm points or calibration settings related to each sensor function.
Use the ‘UP’ / ‘DOWN’ keys to set the required alarm points or leave the alarm point at zero for no
alarm. e.g.
S1 LOALM 650 RPM (SHAFT 1 LOW ALARM)
To cancel an alarm press reset to zero the alarm point. e.g.
S1 LOALM 0 RPM
SHAFT 1 - 5 ALARM CALIBRATION (PORTS 1 - 5)
For each of the enabled Shafts 1 - 5, you may set a LO or HI alarm point.
Press the “CAL” key in succession to select each alarm setting. Use ‘UP’ / ‘DOWN’ key to set each alarm point then press “CAL” to step onto the next selection. e.g.
S1 LOALM 150 RPM
(SHAFT 1 LO ALARM)
e.g.
S1 HIALM 750 RPM
(SHAFT 1 HI ALARM)
Set zero to disable any alarm point.
BIN / TANK 1 & 2 ALARM CALIBRATION (PORTS 1 & 2)
For each of the enabled “BIN / TANK” level sensors you must nominate if the alarm is for ‘FULL’ or
‘LOW’ level. Press the “CAL” key in succession to display BIN ALARM status, then use ‘U’P /
‘DOWN’ keys to toggle between ‘FULL’ or ‘LOW’ bin activation. e.g.
BIN 1 ALARM FULL
Activates when the sensor is completely covered for 3 seconds or more.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
29 e.g.
BIN 1 ALARM LOW
Activates when sensor is completely uncovered for 3 seconds or more.
COUNTER ALARM CALIBRATION (PORT 3)
If the counter function is enabled for Port 3 then a counter total alarm point may be set.
Press the “CAL” key to display “COUNTER ALM” and use ‘UP’ / ‘DOWN’ keys to set desired
counter alarm point. e.g.
COUNTER ALM 520
This will activate the alarm after 520 counts. Set zero for no alarm.
PRESSURE CALIBRATION (PORT 4)
Press “CAL” key to display “PRESSURE LO” or “HI” alarm point, then use ‘UP’ / ‘DOWN’ keys to set required alarm points. e.g.
PRESS LO 150 KPA
PRESS HI 450 KPA
Set zero for no alarm on “HI” or “LO”.
TEMP CALIBRATION (PORT 4)
If the “TEMPERATURE” function is enabled you can set a “HI TEMP” alarm point only.
Press “CAL” key to display “TEMP HI” alarm point, then use ‘UP’ / ‘DOWN’ keys to set required
alarm point. e.g.
TEMP HI 110
° C
Set zero for no alarm.
FLOW CALIBRATION (PORT 5)
When using the flow sensor press the “CAL” key to step through the following options. Then use
‘UP’ / ‘DOWN’ keys to set the data.
1. Set the target application rate. e.g.
SET RATE 75.0 L/HA
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
30
2. If you want an alarm for excessive rate variation you must also set the allowable % error (0% ERROR = NO ALARM). e.g.
ERROR 10%
3.
This means the “HI” or “LO RATE ALARM” will activate if the rate varies outside + / - 10% of the set rate.
To activate the 100 litre low tank alarm, enter the spray tank holding capacity. e.g.
TANK VOL 1500 L
4. The correct flow sensor “PULSE PER LITRE (PPL)” factor must be entered. This is essential for accurate operation. e.g.
FLOW PPL 110.5
All flow sensors output a slightly different number of pulses per litre of liquid throughput. This may vary due to plumbing differences, wear or liquid viscosity.
Each Farmscan flow sensor is factory tested and has a unique PPL factor engraved on the underside of the flow sensor body e.g. PPL 110.5.
The factory PPL factor is true for water and will be accurate to within +/- 2% over the entire operating range of the flow sensor.
More accurate calibration can be achieved using the flow PPL calibration procedure explained on the next page.
FLOW PPL CALCULATION PROCEDURE
If you would like to check or improve the flow sensor accuracy, follow this procedure:
1. Make sure the flow sensor is fully primed with the liquid to be measured.
(A ball valve or solenoid valve shut off system should be installed down stream to stop / start the test).
2. Prepare a container of known quantity to catch the output.
20 LITRES OR MORE FOR 1" FLOWSENSOR
100 LITRES OR MORE FOR 2" FLOWSENSOR display. e.g.
TEST FLOW 0
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
4.
31
Open the valve until the required test batch quantity is obtained and take note of the total
“TEST FLOW” pulses counted. e.g.
TEST FLOW 2344
5. Check the liquid quantity with a graduated jug, then divide the pulses by the number of litres.
2344
÷ 21.4 =
6.
109.5 ppl
Now press “CAL” key until “FLOW PPL” is displayed and set the correct flow PPL factor using the ‘UP’ / ‘DOWN’ keys.
7. e.g.
FLOW PPL 109.5
Recheck the calibration a couple of times to be sure.
FAN CALIBRATION (PORT 5)
If the “FAN” function is enabled for Port 5, then you may set a slow or fast fan RPM alarm point.
Press “CAL” key in succession until fan alarm point is displayed. e.g.
FAN SLOW 0 RPM
Use ‘UP’ / ‘DOWN’ keys to set the required slow RPM alarm point.
Press “CAL” key again to step to “FAN FAST” alarm point. e.g.
FAN FAST 0RPM
Use ‘UP’ / ‘DOWN’ keys to set the required fast RPM alarm point.
NOTE :
Set zero RPM for either fast or slow if no alarm point is required.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
32
3.6 REMOTE RUN / HOLD CALIBRATION
If the “RUN / HOLD” facility is being activated remotely, the connection may be either to an existing switch that turns power on to run the machine, e.g. electric over hydraulic control.
Alternatively, power may be off when the machine is operating, e.g. an electric clutch that is normally engaged without power and disengages with power on.
Press the “CAL” key in succession to display the “RUN / HOLD” calibration.
When the remote “RUN / HOLD” calibration is set to “DISABLED”, then only the front panel “RUN
/ HOLD” key is able to be used. e.g.
RUN/HOLD DISABLED
To activate the remote “RUN / HOLD” function for power on to run, use ‘UP’ / ‘DOWN’ keys to set
“RUN / HOLD ACTIVE ON”. e.g.
R / HLD ACTIVE ON
To activate the remote “RUN / HOLD FUNCTION” for power off to run, set “RUN / HOLD ACTIVE
OFF”. e.g.
R / HLD ACTIVE OFF
Whenever the monitor is in “RUN MODE” (active), the front key panel “RUN / HOLD” can still be used to place the monitor in “HOLD” mode.
3.7 CALIBRATION WARNING
The RFM MONITOR has a unique protection system that compares and checks all your calibration settings to warn if any calibration factor becomes corrupted (changes value without your knowledge).
This is not a regular occurrence, but could be caused in a 'noisy' electrical environment e.g. An old petrol truck with wire ignition leads or faulty alternator.
When a corruption is detected, the monitor will beep continuously and the readout will display
“CHECK CAL” warning. e.g.
CHECK CAL
Press the “CAL” key and check all calibration factors.
See the next page for the total reset procedure to be performed if “CHECK CAL” is displayed.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
33
TOTAL RESET PROCEDURE
It is recommended that if the “CHECK CAL” warning is displayed, a total reset should be performed. See below.
1.) Switch unit off
2.) Hold finger on reset key
3.) Switch unit on leaving your finger on the reset key.
4.) After startup sequence has been completed remove your finger from the reset key and go into the calibration mode and re-enter all figures.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: OPERATION
34
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: TROUBLESHOOTING
4.0 TROUBLESHOOTING 2200 RFM
PROBLEM POSSIBLE CAUSE / REMEDY
a) Remove power from rear of surveillance for 60 seconds to reset internal fuse. Reconnect power and test. MONITOR WHEN ON /
OFF KEY PRESSED b) Test voltage is 12 - 13.8V dc from battery.
OUT OR GREY
SQUARES APPEAR ON
HALF THE READOUT.
DISPLAY - INDICATES
CALIBRATION FACTORS
LOST FROM MEMORY. a) b) ve Pin 10. d) Check that no other electrical device is connected to the same power cable. e) Unable to locate fault - contact nearest dealer or authorised service agent.
If display rectifies when engine running this indicates battery in poor condition.
If problem persists when engine running, then voltage supply is low or low current is problem due to poor connection at battery, corroded inline fuse holder in power cable, or other equipment connected to power cable. c) Clean battery terminals and power cable connections. d) Make sure power cable is direct to battery terminals. a) b)
See calibration warning instructions Section 3.8 in this manual.
If problem occurs regularly, then it is probably caused by outside interference. See "Interference Causes and
Remedies" troubleshooting section 19
35
FAST OR TOO SLOW memory backup chip. In this case all calibrations will be lost from memory whenever the power switch is turned
"OFF". See section 2.2 this manual. a) Re check "WHEEL" calibration is measured correctly and measured in metres eg 2.445 metres.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: TROUBLESHOOTING
TROUBLESHOOTING 2200 RFM
PROBLEM POSSIBLE CAUSE / REMEDY
5. SPEED READOUT JUMPY a) Make sure magnet is facing sensor correctly as shown in section
2.4 "WHEEL SENSOR INSTALLATION". (Use of an alternative magnet may cause problems due to wrong orientation.) b) Check that wheel magnet is 15 - 20 mm away from wheel sensor as they pass. Magnet too close can cause jumpy speed. c) If readout is jumpy, it indicates that the impulses from the sensor are inconsistent. Check for poor or intermittent connection to sensors.
If speedo sensor, check that drive cable is not binding.
Is the wheel loose? d) If fault can not be found, press “TEST” key on monitor until
“TEST WHEEL” is displayed. Drive slowly forward and listen to the beeps. The sound should be consistent and steady at a fixed speed. If the sound is jumpy, wiring is OK, then replace sensor. e) If the beeps can be heard whilst stationary, then interference could be the cause. See Troubleshooting Section 19
"interference Causes and Remedies".
AT ZERO
STAYS a) b)
Check wheel calibration is set correctly - not zero.
Check clearance between wheel magnet and sensor is 15 -
20mm. c) Press “TEST” key to display “TEST WHEEL” then disconnect sensor at furthest point from monitor d) Use a short piece of wire or long nose pliers to make a short circuit across the pins corresponding to black and white wires of sensor cable connected to the monitor. e) If the monitor beeps with short circuit then monitor and wiring okay- replace sensor. f) If no response repeat short circuit test at draw bar connection back to monitor. If beep ok, then cable to sensor at fault. g) If still no response, short circuit across pins 6 and 7 of green connector plug into monitor. If beep ok, then cable to draw bar at fault. h) If no response, return monitor to your nearest Farmscan dealer or authorised Farmscan service agent.
36
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor: TROUBLESHOOTING
TROUBLESHOOTING 2200 RFM
PROBLEM POSSIBLE CAUSE / REMEDY
PROCEDURE
8. TOTAL AND TRIP AREA
INCORRECT
9. TOTAL AND TRIP AREA
WON'T RECORD
MULTIMETER ONLY. a) Disconnect wheel sensor from cable. b) Switch multimeter "ON" and select "OHMS" scale. c) Touch test probes together and meter needle should swing to right of scale indicating "0" OHMS resistance. (If digital meter display - should read zero). d) Move wheel sensor magnet away from sensor and connect test probes to wheel sensor pins. If meter goes to zero, then sensor is short circuit (faulty). If the meter stays to the left of scale, hold wheel magnet in front of sensor, meter should go straight to zero. If meter fails to change, then sensor is open circuit. (faulty) a) Check “SPEED” readout is correct and steady - if not, this will affect the area totals.
See Troubleshooting Section 4 b) Recheck width calibration is set correctly in metres. c) Is the machine overlapping or overcounting headlands. a) Check that “SPEED” readout is working. If not see Trouble shooting Section 4. b) Press “RUN/HOLD” key to make certain monitor is "OFF
HOLD". c) If remote ‘RUN / HOLD’ not used then switch to “CAL” and check that Remote Run / Hold option is “DISABLED”. d) If remote ‘RUN / HOLD’ is used, then switch implement on and monitor should go "OFF HOLD". If reverse occurs, then switch to “CAL” mode and reverse run / hold active off / on calibration.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
37
2200 RFM monitor: TROUBLESHOOTING
5.0 INTERFERENCE CAUSES AND REMEDIES
CAUSES
Noisy wire ignition leads on petrol engine or pump motor.
Faulty Alternator
Other electrical equipment running off monitor power cable
Calibrations get corrupted when solenoids / clutch switched off.
REMEDIES
Replace with carbon leads. Fit suppressors to coil and distributor.
Exchange it
Run separate power cable direct to 12V battery for monitor.
Make sure monitor has its own separate power cable direct to 12V battery. Fit diode across solenoid coil / clutch to clamp spike. Run power cable physically away from solenoid / clutch wiring.
NEED MORE HELP? a) b)
Contact nearest Farmscan Dealer.
Contact Computronics International P/L
Sarich Park
Bentley Australia
Phone: +61 8 9470 1177 (all hours)
Fax:
Email:
Web:
+61 8 9470 2855 [email protected] www.farmscan.com
38
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
2200 RFM monitor PORT/ SENSOR COMPATIBILITY CHART
39
PORT/SENSOR COMPATIBILITY CHART
SENSOR
OPTION
2002
WHEEL
SENSOR
2004
RADAR
SPEED
SENSOR
2007
SPEEDO
SENSOR
PORT FUNCTION
RANGE
1 - 50
KPH
0.5-50
KPH
0 - 100
KPH
PORT 1 SHAFT 1
PORT 2 SHAFT 2
PORT 3 SHAFT 3
COUNTER
TONNAGE
2008
PROXIMITY
SENSOR
1-9999 RPM
2009
TAILSHAFT
SENSOR
1-1500 RPM
2030
FLOW
SENSOR
8-200
L/MIN
2050
FLOW
SENSOR
50-500
L/MIN
2015
PRESSURE
SENSOR
0-500 KPA
2025
PRESSURE
SENSOR
0-2500 KPA
2070
ENGINE
TEMP
SENSOR
40-120•C
2080
AIR
PRESSURE
SENSOR
0-25 KPA
2034
PULLEY
SENSOR
50-9999
RPM
2076
SHAFT
SENSOR
1-1500
RPM
2077
SHAFT
SENSOR
50-9999
RPM
2060
BIN / TANK
SENSOR
FULL /
EMPTY
OTHER
• • •
•
REF
3.6
• • •
•
REF
3.6
• • •
REF
3.6
• • •
• • •
PORT 4 SHAFT 4
PRESSURE
0-500
PRESSURE
0-2500/0-25
TEMP
• • •
•
• •
PORT 5 SHAFT 5
•
• •
•
FLOW
FAN
• • •
WHEEL
INPUT
SPEED
SENSOR
NOTE: * Version 3.0y Software must be installed to enable the ‘LOW AIR PRESSURE’ function.
Issue 1.30
Part No:AM-2200/5
Last Update 1//302
![](http://s1.manualzz.com/store/data/010124170_1-3dcda118a625b99da1ccb641638f3e6b-210x147.png)
Advertisement
Key features
- Speed, area, and distance measurement
- Five ports for custom sensors
- Split width calibration
- Memory backup for settings and totals
- Alarm functions for various parameters
- Imperial/Metric switching