A 0 8 1

A 0 8 1
6100A
6180A
MODEL
Paperless Graphic Recorders
Specification Sheet
• Colour touchscreen display
• USB ‘plug & play’
• Up to 48 universal Inputs
• Up to 96MB non-volatile flash
memory
• 125ms parallel sampling
• Compact Flash or Secure
Digital card
The 6000 Series offer unrivalled input accuracy with a 125ms total
sample rate for up to 48 input channels. Input channels are freely
configurable to suit your process requirements. Each instrument has an
intuitive, touch screen display to enable operators to clearly view
process data in varying formats. All have onboard Flash data storage
capability, Ethernet communication and choice of Compact Flash or SD
card. Data is stored in a tamper-resistant binary format that can be used
for secure, long term records of your process. The 6000 Series is truly
designed for todays networked world and can be accessed via a Local
Area Network, dial-up connection, Intranet or Internet.
• Modbus RTU
• Ethernet TCP/IP
Available features
• Web server
• EtherNet/IP server
• Multi-language support
(French, Dutch, German,
Italian, Japanese, Korean,
Portuguese, Russian and
Simplified Chinese)
Display
Channels
Relays
Events inputs
Groups
Auditor features
Virtual channels*
Timers
Alarms
Batch
Bridge-remote
viewing software
Screen builder
Security
Configuration software
Review/Quickchart Lite
software
Standard views
6100A
6180A
5.5” 1/4 VGA
12.1” XGA
18
48
12
27
24 (6 per option card)
6 standard (12 optional)
Auditor or audit trail
36, 96, 128
Fitted as standard
4 per channel
Optional
Lite as standard (Full optional)
24 (optional)
Unlimited unique user names with configurable
access permissions and passwords
Standard
Standard
Vertical and horizontal trending,
Vertical and horizontal bargraphs,
Circular trend and numeric values
* Virtual channels can be configured as maths, totalisers, counters or comms
imagine absolute data records forever
Data logging and archiving
Modbus master
The 6000 Series recorders have internal Flash memory for secure
data storage. They are also able to accept various removable media
types (Compact Flash, SD card or USB memory stick). Data stored
within the internal memory can be archived to the removable media
on demand or at preset intervals. The 6000 will give an indication of
how long its internal memory and that of the removable media
installed will last according to the configuration of the recorder.
Allows users to view data from multiple instruments connected either
by a local Network connection using Modbus TCP, or a Serial
connection using Modbus RTU.
ASCII printer output (reports)
Fitted as standard the ASCII text printer option provides the 6000
Series with the ability to generate up to 10 simple reports that can be
directed to a Serial ASCII text printer. Reports, triggered by an
event/job can be configured to contain parameters such as time and
date, batch names, process values and user defined messages.
All 6000s have Ethernet capability. The 6000 can be configured to
archive to the removable media and/or over Ethernet. Archiving files
over Ethernet effectively gives a secure, infinite archiving capacity.
Approximate duration for continuous recording of one group of six
channels, high compression:
Archive Media
Dynamic Host Configuration Protocol (DHCP)
Sample Rate
0.125s
0.5s
1s
5s
10s
30s
Dynamic Host Configuration Protocol, the successor to BootP, allows
a 6000 Series host to obtain Network parameters, such as IP address,
Subnet Mask, default gateway and DNS server address dynamically.
The implementation of DHCP on the 6000 Series significantly
reduces the overhead for maintaining a network of instrumentation.
60s
32Mb Internal
Flash (approx. 4
million samples)
2.83 days 11.3 days 22.6 days 113 days 226 days 1.86 yrs
3.7 yrs
64Mb CF Card
or USB memory
stick (approx. 8
million samples)
5.66 days 22.6 days 45.3 days 226 days
1.2 yrs
3.7 yrs
7.4 yrs
256Mb CF Card
or USB memory
stick (approx, 32
million samples)
22.6 days 90.6 days 181 days
2.4 yrs
4.9 yrs
14.8 yrs
20 yrs
9.6 yrs
19 yrs
58 yrs
116 yrs
Specification
Recorder
1Gb CF Card
or USB memory
stick (approx. 125
million samples)
88 days
354 days
8Gb CF Card
or USB memory
stick (approx. 1000
million samples)
1.9 yrs
7.8 ys
16Gb CF Card
or USB memory
stick (approx. 2000
million samples)
3.8 yrs
15.6 yrs
1.9 yrs
15.2 yrs
152 yrs
464 yrs
928 yrs
30.4 yrs 153.6 yrs 304 yrs
928 yrs
1856 yrs
Ethernet (FTP Server)
76.8 yrs
Environmental performance
Temperature limits Operation:
Storage:
Operation:
Humidity limits
Storage:
Protection Bezel and display:
Sleeve:
6100A Portable case option:
Shock:
Vibration (10 to 150Hz):
Altitude:
0 to +50°C
–20 to 60°C
5% to 80% RH
5% to 90% RH
IP66
IP20
IP21
BS EN61010
BSEN60873, Section 9,18
<2000 metres
Infinite
Approvals
Electromagnetic compatibility CE, cUL (EMC)
UL file number:
e57766
Emissions and immunity:
BS EN61326
Time synchronisation (SNTP)
The 6000 Series support Simple Network Time Protocol which, when
enabled, updates the instrument time every 15 minutes from the
configured SNTP server. The unit can also act as a Unicast SNTP
server on the network, allowing client instruments to synchronise with
the 6000 Series to a resolution of one millisecond.
Electrical safety
(BS EN61010):
Batch recording
POLLUTION DEGREE 2
Normally, only non-conductive pollution occurs. Occasionally, however, a
temporary conductivity caused by condensation shall be expected.
Up to ten user-defined fields can be used to enter batch specific data.
Field Descriptor
Operator entered batch information
– up to 20 characters
– up to 60 characters
Physical
Panel mounting:
Panel mounting angle:
6100A
Bezel size:
Panel cutout dimensions:
Depth behind bezel rear face:
Weight:
6180A
Bezel size:
Panel cutout dimensions:
Depth behind bezel rear face:
Weight:
The user can choose to log any number of the given fields on start
and/or stop of a batch. The information will appear on the chart as a
message and cannot be separated from the process data to which it
relates.
Auditor features
Auditor
Designed to meet the requirements of the FDA Regulation 21 CFR
Part 11 for Electronic Records and Signatures, this software option
provides the 6000 Series with additional security such as password
ageing, electronic signatures and time stamped audit trail.
Operator interface
Type:
DIN43700
±45°
144 x 144mm
138 x 138mm (both –0/+1mm)
246.5mm (284 LTC)
3kg max. (5kg if fitted in portable case)
292 x 292mm
281 x 281mm (both –0/+1mm)
261mm
7kg max.
Colour TFT LCD with cold cathode
backlight, fitted with resistive, analogue,
Touch-Panel
Size and resolution
Model 6100A: 1/4VGA (320 x 240 pixels) 5.5”
Model 6180A: XGA (1024 x 768 pixels) 12.1”
Audit trail
A sub-set of the Auditor which provides the 6000XIO with a time
stamped audit trail. It does not include password ageing and
electronic signatures.
Power requirements
Supply voltage
Standard: 100 to 230V ac ±15%; 47 to 63Hz or
110 to 370V dc
Power (Max):
60VA (Inrush current 36A)
Fuse type:
None
Interrupt protectionStandard: Holdup >200msec, at 240V ac, with full load
Mircosoft® Active Directory® directory service
A utility intended for User Access Administration of PCs. It is a tool used
by the IT administrators to manage user access across the company
wide network. It allows users to be given access according to their
functions by allocating them to a group with defined privileges. It also
includes the necessary features such as password expiry, auto-logout,
minimum length password, etc. It allows the users to manage their
password from any node on the system.
Eurotherm Part No. HA029073 Issue 7 June 11
Installation cat. II; Pollution degree 2
INSTALLATION CATEGORY II
The rate impulse voltage for equipment on nominal 230V mains is 2500V.
2
6100A, 6180A Specification Sheet
Back-up battery
Type:
Support time (RTC):
Replacement period:
Stored data:
Update/archive rates
Input/Relay-output sample rate:
Trend update:
Archive sample-value:
Display value:
Poly-carbonmonofluoride/lithium
(BR2330) Part No. PA261095
1 year min. with recorder unpowered
3 years
Time; date; values for totalisers, counters
and timers; batch data; Fvalue,
Rolling average, Stopwatch etc.
DC Input ranges
Shunt:
Additional error due to shunt:
Additional error due to
attenuator:
Performance:
Ethernet communications
Type:
10/100baseT Ethernet.
(IEEE802.3)
Protocols:
TCP/IP, FTP, DHCP, BOOTP, SNTP, Modbus,
SMTP,
ICMP, EtherNet/IP server
Cable
Type: CAT5
Maximum length: 100 metres
Termination: RJ45
Terminals to ground:
Transmission standard:
Input board
General
Input types:
dc Volts, dc millivolts,
dc milliamps (with shunt),
Thermocouple, 2/3-wire RTD
Contact closure (not Channels 1, 7, 13, 19,
25, 31, 37, 43) >60 ms
Input type mix:
Freely configurable.
Maximum number of inputs: 6 per board
A/D conversion method:
>16 bits, 2nd order delta sigma
Input ranges:
See Table1 and Table 2 below
Termination:
Edge connector / terminal block
Noise rejection (48 to 62Hz): Common mode: >140dB (channel to
channel and channel to ground)
Series mode: >60dB.
Max. common mode voltage: 250 Volts continuous
Max. series mode voltage:
45mV at lowest range;
23.74 Volts peak at highest range
Isolation
Channel to channel: 300V RMS or dc (double insulation)
Channel to common
electronics: 300V RMS or dc (double insulation)
Channel to ground: 300V RMS or dc (basic insulation)
Dielectric strength
(BS EN61010)
(1 minute type tests)
Channel to channel: 2500V ac
Channel to ground: 1500V ac
Insulation resistance:
>10MΩ at 500 V dc
Input impedance:
38mV, 150 mV, 1 V ranges: >10MΩ;
20V range: 65.3kΩ
Over voltage protection:
50 Volts peak (150V with attenuator)
Open circuit detection:
± 57nA max.
Recognition time:
500msec
Minimum break resistance:
10MΩ
Maximum error
(instrument
at 20°C)
Range
High
Range Resolution
-38mV
38mV
1.4µV
0.013% I/P + 0.031% 0.030% I/P + 0.052%
25ppm
-150mV 150mV
25ppm
5.5µV
0.013% I/P + 0.028% 0.029% I/P + 0.039%
-1V
1V
37µV
0.013% I/P + 0.024% 0.029% I/P + 0.029%
25ppm
-20V
20V
720µV
0.075% I/P + 0.027% 0.393% I/P + 0.033%
388ppm
T/C Type
Overall range
(°C)
Standard
B
0 to +1820
IEC 584.1
C
D
E
G2
J
K
L
N
R
S
T
U
NiMo/NiCo
Ni/NiMo
Platinel
Pt20%Rh/
Pt40%Rh
0 to +2300
0 to +2495
–270 to +1000
0 to +2315
–210 to +1200
–270 to +1372
–200 to +900
–270 to +1300
–50 to +1768
–50 to +1768
–270 to +400
–200 to +600
–50 to +1410
0 to +1406
0 to +1370
0 to +1888
Max linearisation
error
0to400°C=1.7°C
400to1820°C=0.03°C
Hoskins
0.12°C
Hoskins
0.08°C
IEC 584.1
0.03°C
Hoskins
0.07°C
IEC 584.1
0.02°C
IEC 584.1
0.04°C
DIN43710:1985 (To IPTS68)
0.02°C
IEC 584.1
0.04°C
IEC 584.1
0.04°C
IEC 584.1
0.04°C
IEC 584.1
0.02°C
DIN43710:1985
0.08°C
ASTM E1751-95
0.06°C
Ipsen
0.14°C
Engelhard
0.02°C
ASTM E1751-95
0.07°C
Table 3 Thermocouple types and ranges
Resistance inputs
Ranges (including lead resistance):
Influence of lead resistance Error:
Mismatch:
Temperature scale:
Accuracy and resolution:
RTD types and ranges:
RTD Type Overall range
(°C)
Cu10
Cu53
JPT100
Ni100
Ni120
Pt100
Pt100A
Pt1000
Worst case
temp
Performance
Input per °C
Low
Range
ITS 90
0.05 nA
Off, internal, external, remote
1°C max with inst. at 25°C
50:1 minimum
High, low or none selectable for
each thermocouple channel
0.01°C (typ.) if high or low selected
See Table 3
Additional error:
Types and ranges:
Installation category II;
Pollution degree 2
50V RMS or dc (basic insulation)
EIA232 or EIA485 (software selectable)
Typical error
(instrument
at 20°C)
Range
0.2% of input
See Table 1
Temperature scale:
Bias current:
Cold junction types:
CJ error:
CJ rejection ratio:
Upscale/downscale drive
2
ASCII (typical applications: Input of ASCII
string inputs from Barcode readers, Credit
card readers etc.)
ASCII printer support
Modbus RTU Master and Slave
Isolation (dc to 65Hz
BS EN61010):
Externally mounted resistor modules
0.1% of input
Thermocouple data
Serial communications option
No of ports:
Protocol:
8Hz
8Hz maximum
Latest value at archive time
Latest value at display update time
(8Hz)
–20 to +400
–70 to ± 200
–220 to +630
–60 to +250
–50 to +170
–200 to +850
–200 to +600
–200 to +850
0 to 150Ω, 0 to 600Ω, 0 to 5kΩ
Negligible
1Ω/Ω
ITS90
See Table 2
See Table 4
Standard
Max linearisation
error
General Electric Co.
RC21-4-1966
JIS C1604:1989
DIN43760:1987
DIN43760:1987
IEC 751
Eurotherm Recorders SA
IEC 751
0.02 °C
<0.01°C
0.01 °C
0.01 °C
0.01 °C
0.01 °C
0.09 °C
0.01 °C
Table 4 RTD types and ranges
Table 1 Voltage ranges - accuracy and resolution
Low
Range
High
Range Resolution
Typical error
(instrument
at 20°C)
Range
Maximum error
(instrument
at 20°C)
Range
Worst case
temp
Performance
Input per °C
0Ω
150Ω
5mΩ
0.027% I/P +0.034%
0.037% I/P + 0.077%
30ppm
0Ω
600Ω
22mΩ
0.027% I/P +0.035%
0.037% I/P + 0.057%
30ppm
0Ω
5KΩ
148mΩ
0.030% I/P + 0.034% 0.040% I/P + 0.041%
30ppm
Table 2 Resistance ranges - accuracy and resolution
Eurotherm Part No. HA029073 Issue 7 June 11
3
6100A, 6180A Specification Sheet
Transmitter PSU
Portable
Isolated, 6100A recorder only
Number of outputs:
Three
25V nominal
Output voltage:
20mA per output
Maximum current:
Installation category II;
Isolation
(dc to 65Hz; BS61010):
Pollution degree 2
Channel to channel: 100V RMS or dc (double insulation)
Channel to ground: 100V RMS or dc (basic insulation)
Fuse (20mm Type T)
Supply voltage: 110/120V ac: 100mA
220/240V ac: 63mA
Portable option
6100A is available as a portable
unit with either Thermocouple
(TC), General or HTM2010
connections
Relay output board
General
Max. number of
relay boards
6100A:
6180A:
No. of relays per board:
Estimated mechanical life:
Update rate:
4 (max. no of relay outputs = 12)
9 (max. no of relay outputs = 27)
3 per C/O
30,000,000 operations
See ‘Update rates’ in ‘Recorder
Specification’ above
6180A is available with optional
carry handle and feet for
portability
AC load ratings
Derating
The figures give below are for resistive loads. for reactive or inductive
loads, de-rate in accordance with Graph 1, in which:
F1 = Actually measured results on
representative samples
F2 = Typical values according to experience
Contact life = Resistive contact life x reduction factor
Max. switching power:
500VA
250V providing this does not cause the
Max. contact voltage:
maximum switching power (above) to be
exceeded
Max. contact current:
2 Amps providing this does not cause the
maximum switching power (above) to be
exceeded
DC Voltage (Volts)
Reduction Factor F
F2
F1
0.5
0.4
1
0.8
Relays
Serial
Comms
Transmitter
PSU
Event
I/P
General
18
4
Yes*
Yes
Yes*
Yes*
PORTUTC
15
0
No
Yes
No
No**
6100A
Installation category II;
Pollution degree 2
300V RMS or dc (double insulation)
300V RMS or dc (basic insulation)
0.6
0.3
Option
Slots**
Portable mechanical details
See Graph 2 for operating volt/amp
envelope
Max. contact voltage/current: See Graph 2 for examples
F
1
0.9
0.8
0.7
Max. No
of I/Ps**
** Mutually exclusive
* Requires one option slot
DC load ratings
Max. switching power:
Safety isolation
Isolation
(dc to 65Hz; BS EN61010):
Relay to relay:
Relay to ground:
6100A
0.6
0.4
Power factor (cos f)
0.2
Graph 1
Derating curves for ac loads
Max. DC load breaking capacity
300
200
resistive load
100
50
40
30
20
inductive
load (L/R
= 20msec)
10
0.1 0.2 0.5 1 2
5
DC current (Amps)
20
Graph 2
DC load switching curves
Event input
Number of inputs:
Max. number of boards
6100A:
6180A:
Isolation
Event input to ground:
Event input to Event input:
Recognition levels ‘Active’:
‘Inactive’:
Maximum frequency:
Minimum pulse width:
Contact resistance Event:
Current sink (voltage I/P):
6 discrete inputs
6180A
4
4
50V RMS or dc (double insulation)
0V
–30V to +0.8V
+2 to +30V
8Hz
62.5ms
Active if resistance <35KΩ
Inactive if resistance >200KΩ
Status not defined if 35KΩ < resistance
<200KΩ between input terminal and ‘C’
terminal
10mA
Eurotherm Part No. HA029073 Issue 7 June 11
4
6100A, 6180A Specification Sheet
Mechanical details
6100A
6180A
Isolated transmitter power supply wiring (6100A only)
Long Terminal Cover
Recorder rear terminal panel
Channel input
Input board wiring
Transmitter Power Supply PCB
V+
V–
I
Channels
Red
Black
Red
Black
Red
Black
Black
Red
R
User Terminal Block
–
+
–
+
–
Relay board wiring
+
Three changeover relays
–
+
Other transmitters
1
2 Option
boards
0mA
4mA
20mA
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
nc c no nc c no nc c no
Transmitter
Voltages generated by
various currents for
R=100W and R=250W
(R minimum spec)
= 1.4W ±1%
2
Relay
1
2
3
nc c no nc c no nc c no
1
2
3
Only one channel shown for clarity
c
100W 250W
0V
0V
0.4V
1.0V
2.0V
5.0V
Eurotherm Part No. HA029073 Issue 7 June 11
5
6100A, 6180A Specification Sheet
Input board signal wiring
V+ V-
I
V+ V-
I
V+ V-
I
V+ V-
I
V+ V-
I
V+ V-
I
I
V+ V-
I
nc
Shunt
com
+
+
–
–20 to +20V dc
Thermocouples
dc mV
–
RTD
RTD
–
Attenuator
Assembly
+
Potentiometer
no
Minimum
contact = 60 ms
3-wire resistance
thermometer
DC millamps
–200 to + 200V dc
Shunt assembly
100W = LA246779UK10
250W = LA246779UK25
Attenuator assembly
LA244180
2-wire resistance
thermometer
Contact closure
(Not Chs 1,7,13 etc.)
Potentiometer
Event input board wiring
1
2
3
4
5
6
7
1
2
3
4
5
6
C
1
2
3
4
5
6
C
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
2 Option boards
Event input number
1
2
3
4
5
6
C
1
2
3
4
5
6
C
Behaviour undefined
for +0.8 < Vin < +2
Input 6 shown
inputs 1-5 identical
2 to 30V
0.8 to –30V
User 0V
Contact closure inputs
Voltage inputs
Rear terminal connections
6100A
Low supply voltage option
Serial communication port pinout
Pin
1
2
3
4
5
6
7
8
9
EIA485 (5-wire) EIA485 (3-wire)
Link to pin 7
RxA
Not connected Not connected
Not connected Not connected
Not connected Not connected
Signal ground
Link to pin 8
RxB
Not Connected
TxA/RxB
TxA
Not Connected
TxB/RxA
TxB
Not Connected
5.0V via 1500W
EIA232
Not connected
Rx
Tx
DTR
USB 1
USB 2
1 2 3 4 5
1 2 3 4 5
6 7 8 9
Serial 1
6 7 8 9
Serial 2
Ethernet
connector
(option)
1
2
3
4
1
Supply voltage
Connector
+V or ac
Earth
22
22
1
7 - 12
0V or ac
Option board
Input channels
22
1
1-6
1
Option
boards
22
Channels 13-18
(if fitted) occupy
option board
slots 3 and 4
6180A
1
2
3
4
5
6
7
8
Option
boards
9
43 - 48
1
22
37 - 42
1
Input
channels
1
25 - 30
1
1
1
22
Input
channels
22
7 - 12
1
1-6
Eurotherm Part No. HA029073 Issue 7 June 11
22
19 - 24
22
13 - 18
1
31 - 36
22
22
22
6
6100A, 6180A Specification Sheet
Order codes
1
2
3
4
5
6
7
8
9
10
11
12
13
22
23
24
25
26
27
VH
14
15
16
17
18
19
00
28
29
30
31
32
20
00
33
Basic Product
6100A
6180A
1
100mm TFT 1/4 VGA Display Paperless Graphic Recorder
180mm TFT XGA Display Paperless Graphic Recorder
00
34
11 Memory Card
22 Quantity of Shunts
NOMC
002G
004G
008G
__
Not fitted
2GB Card CF only*
4GB Card CF only*
8GB Card CF only*
Number of Channels
U00
U06
U12
U18
U24
U30
U36
U42
U48
0 Input channels
6 Input channels
12 Input channels
18 Input channels
24 Input channels (6180A only)
30 Input channels (6180A only)
36 Input channels (6180A only)
42 Input channels (6180A only)
48 Input channels (6180A only)
12 USB Memory Stick Size
NOMS
002GMS
004GMS
008GMS
2
Not fitted
2GB*
4GB*
8GB*
13 Rear USB
0RUSB
2RUSB
XXX
3
21
No rear USB ports
2 USB ports at rear
14 Serial Communications Ports
Case Options
PANEL
PORTGEN
PORTUTC
PORTVTC
CH
PMHD
PMTN
Panel mounting
General Portable (6100A only)
Universal Thermocouple Portable (6100A only)
Voltage Input only Portable (6100A only)
Carry handle (Bezel Colour Silver)
Panel mounting with Heavy Duty Case Clamps
Panel mounting with Thin panel mounting kit
0SRL
2SRL
Not fitted
2EIA 232/422/485
15 EtherNet Communications
Protocol
NONE
ESERV
Not fitted
EtherNet/IP server
16 Calibration Certificates
4
Lock
NOLCK
LOCK
Media lock not fitted
Electronic lock fitted
NOCAL
CAL
Not required
Calibration certificate
Bezel Colour
SLV
GRN
BLK
6
Power Supply
VH
7
90-264V ac (110-370V dc) 47-63Hz
24V Isolated Transmitter Power Supply
NONE
115TPS
230TPS
8
Silver including portable options
Eurotherm Green
Black
Not fitted
110-120V 3 channel TPS (6100A only)
220-240V 3 channel TPS (6100A only)
Non Standard
XXXXXX
23 Shunt Value
NOS
100
250
Not required
100 ohm shunts
250 ohm shunts
24 Qty of 100:1 Attenuators
__
Enter qty required
25 Warranty
XXXXX
WL005
Standard warranty
Extended warranty
26 Bridge
BLITE
BFULL
Lite (supplied as standard)
Full
27 Review & Quickchart
RLITE
RFULL
Lite (supplied as standard)
Full
28 Auditor
NOADT
ALITE
AFULL
Not required
Audit Trail
Auditor Full
29 Security Manager
17 Changeover Relays
5
Enter qty required
00
03
06
09
12
15
18
21
24
27
Not fitted
3 (1 option brd)
6 (2 option brds)
9 (3 option brds)
12 (4 option brds)
15 (5 option brds) †
18 (6 option brds) †
21 (7 option brds) †
24 (8 option brds) †
27 (9 option brds) †
† (6180A only)
18 Normally Closed Relays
00
Not fitted
NOSM
Not required
SECMAN Security Manager
(inc. Active Directory)
30 Groups
06GROUP 6 (supplied as standard)
12GROUP 12
31 Maths, Totalisers & Counters
MTC00
MTC36
MTC96
MTC128
19 Normally Open Relays
32 Batch
00
NOBTCH
BATCH
Not fitted
Non standard option
Not required
36 Virtual Channels
96 Virtual Channels
128 Virtual Channels
Not required
Batch
20 Event Inputs
9
Internal Memory
096M
96MB for history – approx. 12 million samples
00
06
12
18
24
Not fitted
06 (1 brd)
12 (2 brds)
18 (3 brds)
24 (4 brds)
10 Removable Media
CF
SD
Compact Flash and Front USB port
Secure Digital and Front USB port
21 Analogue Outputs
00
None
33 Screen Builder
NOSB
ADSB
Not required
Advanced
34 Master Communications
NOMSTR Not required
MSTR16 16 Slaves
MSTR32 32 Slaves
* Please consult Eurotherm for this option
Eurotherm Part No. HA029073 Issue 7 June 11
7
6100A, 6180A Specification Sheet
Eurotherm:
AUSTRALIA Melbourne
T (+61 0) 8562 9800
E [email protected]
AUSTRIA Vienna
T (+43 1) 7987601
E [email protected]
BELGIUM & LUXEMBOURG Moha
T (+32) 85 274080
E [email protected]
BRAZIL Campinas-SP
T (+5519) 3707 5333
E [email protected]
CHINA
T (+86 21) 61451188
E [email protected]
International sales and service
Beijing Office
T (+86 10) 5909 5700
E [email protected]
FRANCE Lyon
T (+33 478) 664500
E [email protected]
GERMANY Limburg
T (+49 6431) 2980
E [email protected]
INDIA Mumbai
T (+91 22) 67579800
E [email protected]
IRELAND Dublin
T (+353 1) 4691800
E [email protected]
www.eurotherm.com
ITALY Como
T (+39 031) 975111
E [email protected]
KOREA Seoul
T (+82 2) 2090 0900
E [email protected]
NETHERLANDS Alphen a/d Rijn
T (+31 172) 411752
E [email protected]
POLAND Katowice
T (+48 32) 78395000
E [email protected]
SPAIN Madrid
T (+34 91) 6616001
E [email protected]
SWEDEN Malmo
T (+46 40) 384500
E [email protected]
SWITZERLAND Wollerau
T (+41 44) 7871040
E [email protected]
UNITED KINGDOM Worthing
T (+44 1903) 268500
E [email protected]
U.S.A. Ashburn VA
T (+1 703) 724 7300
E [email protected]
ED63
© Copyright Eurotherm Limited 2011
Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris, EPower nanodac and Wonderware are trademarks of
Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners.
All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be
stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates, without the prior
written permission of Eurotherm limited.
Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be
changed without notice. The information in this document is given in good faith, but is intended for guidance only.
Eurotherm Limited will accept no responsibility for any losses arising from errors in this document.
Eurotherm Part No. HA029073 Issue 7 June 11
8
6100A, 6180A Specification Sheet
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement