Brocade Communications Systems BROCADE 4424 BLADE SERVER 53-1000571-01 Technical data

Add to my manuals
48 Pages

advertisement

Brocade Communications Systems BROCADE 4424 BLADE SERVER 53-1000571-01 Technical data | Manualzz

November 2007

Brocade 4424 Blade Server

SAN I/O Module

Hardware Reference Manual

Copyright © 2007 Brocade Communications Systems, Inc. All Rights Reserved.

Brocade, the Brocade B weave logo, Fabric OS, File Lifecycle Manager, MyView, Secure Fabric OS, SilkWorm, and StorageX are registered trademarks and the Brocade B wing logo, SAN Health, and Tapestry are trademarks of Brocade Communications

Systems, Inc., in the United States and/or in other countries. FICON is a registered trademark of IBM Corporation in the U.S. and other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.

Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.

Export of technical data contained in this document may require an export license from the United States government.

The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.

The product described by this document may contain “open source” software covered by the GNU General Public License or other open source license agreements. To find-out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit

http://www.brocade.com/support/oscd.

Brocade Communications Systems, Incorporated

Corporate Headquarters

Brocade Communications Systems, Inc.

1745 Technology Drive

San Jose, CA 95110

Tel: 1-408-333-8000

Fax: 1-408-333-8101

Email: [email protected]

Asia-Pacific Headquarters

Brocade Communications Singapore Pte. Ltd.

9 Raffles Place

#59-02 Republic Plaza 1

Singapore 048619

Tel: +65-6538-4700

Fax: +65-6538-0302

Email: [email protected]

European and Latin American Headquarters

Brocade Communications Switzerland Sàrl

Centre Swissair

Tour A - 2ème étage

29, Route de l'Aéroport

Case Postale 105

CH-1215 Genève 15

Switzerland

Tel: +41 22 799 56 40

Fax: +41 22 799 56 41

Email: [email protected]

Document History

Title

Hardware Reference Manual

Publication Number

53-1000571-01

Summary of Changes

New document

Date

November 2007

Contents

About this document

How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . v

What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi

Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii

Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix

Chapter 1

Chapter 2

Introducing the SAN I/O Module

Dual function and access gateway configurations . . . . . . . . . . . . . . . 1

Determining module configuration . . . . . . . . . . . . . . . . . . . . . . . . 1

Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Full Fabric Switch mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Access Gateway mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Ports on Demand (POD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Port side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Nonport side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

SFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

ISL trunking groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Optional features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Unpacking and installing the SAN I/O Module . . . . . . . . . . . . . . . . . . 7

Cabling guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Configuring the SAN I/O Module

Items required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Modify the SAN I/O Module IP address . . . . . . . . . . . . . . . . . . . . . . . 10

Using the SAN I/O Module CLI to set the IP address. . . . . . . . . 10

Using the CMC CLI to set the IP address . . . . . . . . . . . . . . . . . . 11

Using the CMC GUI to set the IP address . . . . . . . . . . . . . . . . . .12

Connecting the SAN I/O Module to the Ethernet network . . . . . . . . 13

Connecting the SAN I/O Module to the fabric. . . . . . . . . . . . . . . . . . 13

Changing from Fabric Switch mode to Access Gateway mode . . . . 15

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-1000571-01 Rev. A iii

iv

Chapter 3

Appendix A

Changing from Access Gateway Mode to Fabric Switch Mode . . . . 17

Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Activating Ports on Demand (POD) . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Activating ports with a POD license . . . . . . . . . . . . . . . . . . . . . . 18

Connecting to the SAN I/O Module Using Web Tools . . . . . . . . . . . . 18

Operating the SAN I/O Module

Interoperability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Port negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Operating system support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Accessing the SAN I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Interpreting POST results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Interpreting LED activity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Locating the serial number . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Removing and replacing the SAN I/O Module. . . . . . . . . . . . . . . . . .23

SAN I/O Module specifications

Access Gateway Mode default port mapping . . . . . . . . . . . . . . . . . .25

Processor and memory specifications. . . . . . . . . . . . . . . . . . . . . . . .25

Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Facility requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Architectural specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Supported HBAs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Fibre Channel standards compliance . . . . . . . . . . . . . . . . . . . . . . . . 27

Regulatory compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

FCC warning (US only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

MIC Statement (Republic of Korea) . . . . . . . . . . . . . . . . . . . . . .28

VCCI statement (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

BSMI statement (Republic of Taiwan) . . . . . . . . . . . . . . . . . . . .29

CE statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Canadian requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Laser compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Environmental regulation compliance . . . . . . . . . . . . . . . . . . . . . . . . 31

China RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Regulatory certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

Index

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-1000571-01 Rev. A

About this document

This document is a hardware reference manual, written for SAN administrators who are using any

Blade Server that supports the Brocade 4424 Blade Server Fibre Channel SAN I/O Module. It provides the information needed to understand the installation, configuration, and maintenance of the Brocade 4424 SAN I/O Module.

NOTE

Through this document, the Brocade 4424 SAN I/O Module is referred to as the SAN I/O Module.

How this document is organized

This document is organized to help you find information that you need as quickly as possible. The document contains the following components:

Chapter 1, “Introducing the SAN I/O Module,”

describes the SAN I/O Module and explains its basic concepts and features. This chapter also provides instructions for unpacking the SAN I/O

Module from its shipping container, references to the appropriate publication for installing the module into the Blade Server Enclosure, and Fibre Channel port cabling guidelines.

Chapter 2, “Configuring the SAN I/O Module” describes how to change the SAN I/O Module’s IP

address, connect the module to the Ethernet network and fabric, change between Access

Gateway and fabric switch modes, activate Ports on Demand (POD), and connect to the SAN

I/O Module using Web Tools.

Chapter 3, “Operating the SAN I/O Module,” provides details about operating and replacing a

4424 Module.

Appendix A, “SAN I/O Module specifications,”

is a product specification reference.

Supported hardware and software

This document includes information specific to the Brocade 4424 SAN I/O Module running

Brocade Fabric OS. For more information about the Fabric OS supported by this product, refer to the related publications on the Brocade Family Documentation CD-ROM shipped with the SAN I/O

Module.

What’s new in this document

This is a new document. For further information, see the Brocade release notes for the Fabric OS released with this product.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01 v

vi

Document conventions

This section describes text formatting conventions and important notices formats.

Text formatting

The narrative-text formatting conventions that are used in this document are as follows: bold text Identifies command names

Identifies GUI elements

Identifies keywords and operands

Identifies text to enter at the GUI or CLI

italic text code

text

Provides emphasis

Identifies variables

Identifies paths and Internet addresses

Identifies document titles

Identifies CLI output

Identifies syntax examples

For readability, command names in the narrative portions of this guide are presented in mixed letter case: for example, switchShow. In actual examples, command letter case is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive.

Notes, attention, caution, and danger

The following notices appear in this document.

NOTE

A note provides a tip, emphasizes important information, or provides a reference to related information.

ATTENTION

An attention alerts you to potential damage to hardware, firmware, software or data.

CAUTION

A caution alerts you to potential injury to personnel.

DANGER

A danger alerts you to potential lethal injury to personnel.

For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Additional information

This section lists additional Brocade and industry-specific documentation that you might find helpful.

Brocade resources

The following related documentation is provided on the Brocade Family Documentation and

Brocade 4424 Documentation CD-ROMs packaged with the SAN I/O Module and on the Brocade

Web site, through Brocade Connect.

NOTE

Go to http://www.brocade.com and click Brocade Connect to register at no cost for a user ID and password.

Fabric OS

• Fabric OS Administrator’s Guide

• Fabric OS Command Reference Manual

• Fabric OS MIB Reference Manual

• Fabric OS System Error Message Reference Manual

• Access Gateway Administrator’s Guide

• SAN TECH NOTE - Preparing to Install the Brocade Access Gateway

Fabric OS Optional Features

• Web Tools Administrator’s Guide

• Fabric Watch Administrator’s Guide

Brocade 4424 Blade Server Fibre Channel SAN I/O Module

• Brocade 4424 Blade Server Fibre Channel SAN I/O Module Hardware Reference Manual (this document).

• Brocade 4424 QuickStart Guide.

• Brocade release notes for Fabric OS version supported by the Brocade 4424.

For practical discussions about SAN design, implementation, and maintenance, you can obtain

Building SANs with Brocade Fabric Switches through: http://www.amazon.com

For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource

Library location: http://www.brocade.com

Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric

OS firmware.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01 vii

Optional brocade features

Optional Brocade features include:

Advanced Performance Monitoring

Enables more effective end-to-end SAN performance analysis to enhance performance tuning, increase productivity, optimize resource utilization, and reduce costs.

Extended Fabrics

Supports the reliable, high-speed connectivity of Brocade switches over dark fiber or Dense

Wave Division Multiplexing (DWDM) equipment at distances up to 500 kilometers to enhance business continuance operations.

Fabric Watch

Continuously monitors SAN fabrics for potential faults based on thresholds set for a variety of

SAN fabric elements and events—automatically alerting administrators to potential problems before they become costly failures.

ISL Trunking

Optimizes the performance and availability of SAN fabrics while simplifying ISL management.

Two 4 Gbit/sec Brocade switches can automatically group up to eight ISLs into a single logical

“trunk,” with a total throughput of up to 32 Gbit/sec.

Other industry resources

For additional resource information, visit the Technical Committee T11 Web site. This Web site provides interface standards for high-performance and mass storage applications for Fibre

Channel, storage management, as well as other applications: http://www.t11.org

For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.org

Getting technical help

Contact your SAN I/O Module support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available:

1. General Information

• Technical Support contract number, if applicable

• SAN I/O Module model

• SAN I/O Module operating system version

• Error numbers and messages received

• supportSave command output

• Detailed description of the problem and specific questions viii 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

• Description of any troubleshooting steps already performed and results

• Serial console and Telnet session logs

• syslog message logs

2. SAN I/O Module Serial Number

The SAN I/O Module serial number and corresponding bar code are provided on the serial number label attached to the module. Following is an example of a serial number and barcode:

FT00X0054E9

FT00X0054E9

3. World Wide Name (WWN). Use the CLI wwn or switchShow commands to display the WWN.

4. Software licenses. Use the CLI licenseIdShow command to display the list of licenses and corresponding license IDs available on the unit.

Document feedback

Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: [email protected]

Provide the title and version number and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01 ix

x 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Introducing the SAN I/O Module

Chapter

1

The Brocade 4424 is a 24-port Fibre Channel module with 8 external ports and 16 internal ports designed for installation in a Dell PowerEdge M1000e Blade Server Enclosure. The product ships with 12 ports enabled and can be upgraded to 24 ports through Ports on Demand (POD) licensing.

These ports support link speeds up to 4Gbit/sec.

Dual function and access gateway configurations

The SAN I/O Module ships in one of two configurations:

• Dual Function configuration. In this configuration, the SAN I/O Module operates in Standard

Full Fabric Switch mode by default. The module can also operate in Access Gateway mode.

• Access Gateway configuration. In this configuration the SAN I/O Module operates exclusively in

Access Gateway mode. Access Gateway simplifies SAN deployment by using NPIV. NPIV provides Fibre Channel switch functions that improve SAN I/O Module scalability, manageability, and interoperability. For more information on Access Gateway, refer to the following:

For a list of SAN I/O Module F_Ports mapped to N_Ports in the SAN I/O Module as shipped

from the factory, refer to “Access Gateway Mode default port mapping” on page 25.

For general information and details on using Access Gateway, refer to the Brocade Access

Gateway Administrator’s Guide.

Since Access Gateway relies on NPIV technology for its connection to the edge fabric you may have to prepare the edge fabric before connecting it to Access Gateway. Please refer to the SAN TECH NOTE – Preparing to Install the Brocade Access Gateway for specific instructions.

NOTE

When shipped in Access Gateway configuration, a Switch (Fabric) license is required to operate the module in Standard Full Fabric Switch mode.

NOTE

Access Gateway cannot be connected directly into an array; it requires a fabric to support NPIV.

Determining module configuration

The factory configuration type is identified by the part number on a label attached to the module.

Refer to Figure 3 on page 5 for label location.

• If the part number is DL-4424-0001, then the SAN I/O Module is configured in Standard Full

Fabric Switch mode. Note that Full Fabric Switch mode is the default setting when shipped from the factory. Access Gateway mode can also be enabled on this module.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

1

2

1

Features

• If the part number is DL-4424-0002, then the SAN I/O Module is configured to run exclusively in Access Gateway mode. To operate in Full Fabric Switch mode, you must have a Switch license.

You may also use the CLI licenseshow command to determine whether the module is Dual Function

(Switch/Access Gateway), or single-function Access Gateway. This command displays current license keys, along with a list of licensed products enabled by these keys. A Dual Function

(Switch/Access Gateway) module should have a “Fabric license” in the command output.

Features

Features available on the SAN I/O Module depend on whether the module is configured in Access

Gateway or Standard Full Fabric Switch mode.

Full Fabric Switch mode

The SAN I/O Module has the following features:

• Up to 8 external autosensing (1, 2, and 4 Gbit/sec) Fibre Channel ports. These are universal and self-configuring ports are capable of becoming one of the following port types:

F_Port (fabric enabled)

FL_Port (fabric loop enabled)

E_Port (expansion port)

These ports are capable of Brocade ISL Trunking with appropriate licensing.

• Up to 16 internal backplane F_Ports. Each port is capable of automatic negotiation to the highest common speed of all connected devices at 4 Gbit/sec.

• Dynamic ports on demand, which allows any port to be activated as needed based on available licenses.

• Frame filtering that augments the hardware zoning capabilities of the Brocade ASIC, which implements hardware zoning at the port level of the SAN I/O Module.

• Brocade ASIC expanded capabilities, including World Wide Name (WWN) and device-level zoning.

• Hardware zoning, implemented by means of a firmware-accessible table per output port.

• Extensive diagnostics and monitoring capabilities.

• Unicast and broadcast data traffic support.

• Up to eight SWL small form-factor pluggable (SFP) optical transceivers.

NOTE

The SAN I/O Module ships with four 4 Gbit/sec SFPs. If you purchase a POD license, you will receive an additional four SFPs.

• One serial console port on the front panel (RJ45 connector).

• The following light-emitting diodes (LEDs) for each external port.

One green/amber LED to indicate status for each port.

One green/amber LED to indicate link speed for each port.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Features

1

If dark, the port is unlicensed.

• The following system LEDs:

One green power LED to indicate module power-on.

One green/amber LED to indicate module status.

One blue, identify module and flash blue to locate module.

See

“Interpreting LED activity” on page 22 for details about the SAN I/O Module LEDs.

Access Gateway mode

• Up to 8 autosensing (1, 2, and 4 Gbit/sec) Fibre Channel ports. These are universal and self-configuring ports capable of becoming:

F_Port (fabric enabled)

N_Port (fabric enabled)

• Up to 16 internal backplane F_Ports. Each port is capable of automatic negotiation to the highest common speed.of all connected devices at 4 Gbit/sec.

• Dynamic ports on demand, which allows any port to be activated as needed based on available licenses.

• Up to eight SWL small-form-factor pluggable (SFP) optical transceivers.

NOTE

The SAN I/O Module ships with four 4 Gbit/sec SFPs. If you purchase a POD license, you will receive an additional four SFPs.

• One serial console port on the front panel (RJ45 connector).

• The following light-emitting diodes (LEDs) for each external port:

One green/amber LED to indicate status for each port.

One green/amber LED to indicate link speed for each port

If dark, the port is unlicensed.

• The following system light-emitting diodes (LEDs):

One green power LED to indicate module power-on.

One green/amber LED to indicate module status.

One blue, identify module and flash blue to locate module.

See

“Interpreting LED activity” on page 22 for details about the SAN I/O Module LEDs.

Ports on Demand (POD)

The SAN I/O Module ships with 12 active ports. You can allocate a POD license to activate 12 additional ports. The SAN I/O Module supports two licensing methods: static and dynamic (module default).

• For Dynamic POD, 12 licenses are available for the first 12 active ports. Ports 17 and 18 are licensed at the factory. The remaining 10 licenses are assigned to active ports as required.

Once licenses are issued, they can be moved from one port to another, making port licensing more flexible.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

3

4

1

Hardware Description

For static POD, Table 1

shows the base internal and external ports that are licensed, as well as the additional 12 ports that can be activated with a POD license. For details about activating and deactivating additional ports when you have POD licensing, refer to

“Activating Ports on

Demand (POD)” on page 17.

TABLE 1

Port Licensing

Ports available

External Ports Internal Ports

Base 17, 18, 19, and 20

POD 0, 21, 22, and 23

1, 2, 3, 4, 5, 6, 7, and

8

9, 10, 11, 12, 13, 14,

15, and 16

Hardware Description

This section describes the physical SAN I/O Module as shipped from the factory. For specifications, such as installed memory, weight and physical dimensions, facility requirements, architectural

specifications, and regulatory compliance, refer to Appendix A, “SAN I/O Module specifications”

Port side

Externally accessible ports and LEDs are on the port side of the SAN I/O Module. The port side faces out when the SAN I/O Module is inserted into the I/O bay of the Blade Server enclosure.

Figure 1 details the port side. For a complete description of the locations and interpretations of

these LEDs, see “Interpreting LED activity” on page 22.

Access the I/O module handle at the front of the port side of the SAN I/O Module. By lifting the handle’s release latch, you can open the handle to remove and insert the unit from the Blade

Server Enclosure.

FIGURE 1 Port Side View

5 6

1

1. Ports with port status and port speed LEDs

2. RJ45 console port

3. SAN I/O Module status LED

4. Power status LED

5. Server management LED

6. SAN I/O Module handle

2 3 4

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Hardware Description

1

The nonport (SAN I/O Module status) LEDs, shown as item 3 of Figure 1

, display SAN I/O

Module-level information as shown in Figure 2

.

FIGURE 2 Other Status LEDs

3

1 2

1 SAN I/O Module status LED

2 Power status LED

3 Server Management LED

Nonport side

The nonport side of the SAN I/O Module (shown in Figure 3 ) is seated into the enclosure. You do

not need to line up the SAN I/O Module as it will seat correctly when the insertion arm is closed.

When the SAN I/O Module is inserted, the backplane connectors activate a connection port, allowing the SAN I/O Module to be configured in the Blade Server Enclosure.

FIGURE 3 Nonport Side, Viewed from Top

1 2 3

1. I/O module handle. Lifting the handle’s release latch opens the handle to install and remove the module from the Blade Server Enclosure.

2. Product label including serial number.

3. Connectors

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

5

6

1

ISL trunking groups

Labeling

Figures 3 shows the labels appearing on the SAN I/O Module. A second serial label is located

beneath the insertion arm on the enclosure (visible only when the arm is extended).

To extend the insertion arm, gently squeeze the release tab (top-to-bottom) and pull outward.

SFPs

The SAN I/O Module was designed to work with small form-factor pluggable (SFP) optical modules and ships with up to eight SWL SFPs.

NOTE

The SAN I/O Module ships with four 4 Gbit/sec SFPs. If you purchase a POD license, you will receive an additional four SFPs.

SFPs provide optical connections to external devices for both SWL and LWL connections. Replace

SFPs with a new pluggable unit rather than replacing the SAN I/O Module. Refer to the manufacturer’s instructions when installing SFPs.

“Removing and replacing the SAN I/O Module” on page 23 provides details about removing SFPs

from the SAN I/O Module.

For a complete list of SFPs and other interoperable hardware, visit the Brocade Connect Web site at: http://www.brocadeconnect.com and follow the links to the latest compatibility matrix. From the main page, select Technical Resource Center, then Documentation Library. Finally, choose

Compatibility and Scalability Information.

ISL trunking groups

Brocade ISL Trunking is optional software that allows you to create trunking groups of ISLs between adjacent switches.

If your SAN I/O Module has a Brocade ISL Trunking license, external ports can be used as a trunking group. Ports that can be used within the same trunking group are color-coded on the SAN

I/O Module’s port side for easy identification.

The external ports are divided into two equal groups:

1. Ports 17, 18, 19, and 20

2. Ports 21, 22, 23, and 0

NOTE

Only the external ports are available for trunking.

The external ports can form 2-port trunks, 3-port trunks, or a 4-port trunk. For details about

Brocade ISL Trunking, see the Brocade Fabric OS Procedures Guide.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Optional features

1

Optional features

The SAN I/O Module supports the following optional software, which is activated with the purchase of the corresponding license key. Applicable options depend on whether the SAN I/O Module operates in Switch or Access Gateway mode.

Full Fabric Switch Mode

• Brocade Advanced Web Tools 1

• Brocade Advanced Zoning 1

• Brocade ISL Trunking

• Brocade Advanced Performance

Monitoring

1.

included with the SAN I/O Module

• Brocade Fabric Watch

• Brocade Secure Fabric OS

• Port on Demand (POD) licensing

• Support for Brocade Fabric Access API and API

Scripting Toolkit

Access Gateway Mode

• Fabric/Switch License

• Brocade ISL Trunking (check for availability)

For detailed information on any of these features, refer to the Brocade Fabric OS Administrator’s

Guide.

Unpacking and installing the SAN I/O Module

If the SAN I/O Module is installed in the Blade Server Enclosure that is shipped to you, skip this section. This section applies when installing a new module in an empty bay or replacing an existing

SAN I/O Module.

NOTE

The SAN I/O Module is designed to work only in I/O bays B1/B2 and C1/C2 of the Dell M1000e

Blade Server Enclosure. Make sure to comply with installation requirements in the Blade Server

Enclosure Hardware Owner’s Manual.

Perform the following steps to remove the SAN I/O Module from its shipping package.

1. Open the shipping box and inspect the contents, making sure that nothing is missing or damaged.

Do not insert a damaged SAN I/O Module into the Blade Server Enclosure. If the SAN I/O

Module appears to be damaged, contact your sales representative before proceeding.

2. Remove the cardboard accessory tray from on top of the SAN I/O Module.

This tray contains the documentation, regulatory statements, product information guide, and

Documentation CD.

3. Remove the SAN I/O Module from the box.

The protective foam ends will slide out with the SAN I/O Module.

4. Remove the foam ends from the SAN I/O Module.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

7

1

Cabling guidelines

5. Be sure that you have taken the necessary precautions for electrostatic sensitivity; then break the seal warning.

6. Slide the SAN I/O Module out of the antistatic sleeve and inspect it carefully for any obvious defects or shipping damage.

7. Locate the label that specifies the part number for the SAN I/O Module. Make a note of the part number because the part number indicates whether the SAN I/O Module was configured at the factory in Access Gateway or Standard Full Fabric Switch mode. (More information on

Access Gateway and Full-Fabric Switch mode is provided in

Chapter 2, “Configuring the SAN I/O

Module”

.)

• If the part number is DL-4424-0003, then the SAN I/O Module is configured in Access

Gateway mode.

• If the part number is DL-4424-0001, then the SAN I/O Module is configured in Full Fabric

Switch mode. Note that Full Fabric Switch mode is the default factory setting when the module is licensed for Dual Function mode. With Dual Function mode, you can enable the module for Access Gateway or Full Fabric Switch mode.

8. For complete instructions to install the SAN I/O Module into the Blade Server Enclosure, refer to the section on installing an I/O module in the Blade Server Enclosure Hardware Owner’s

Manual.

Cabling guidelines

After modifying the SAN I/O Module’s IP address and domain name (if Module is in Fabric Switch mode), we recommend that you cable all external ports to fabric connections before bringing the

SAN I/O Module online. Refer to

Chapter 2, “Configuring the SAN I/O Module,” for steps on

modifying the IP address.

Begin by cabling ports 17, 18, 19, 20, 21, 22, 23, and 0. Ports 17 and 18 are licensed at the factory as part of Dynamic Ports On Demand (DPOD). By cabling these ports first, you will not need to move licenses to other ports you may have cabled.

8 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Configuring the SAN I/O Module

Chapter

2

Use procedures in this chapter to configure the SAN I/O Module to operate on a network and fabric.

Also provided are steps to change the Module’s operating mode (Full Fabric Switch and Access

Gateway modes), activating Ports on Demand (POD), and connecting to the SAN I/O Module using

Web Tools.

NOTE

The SAN I/O Module is configured at the factory for either Access Gateway mode or Dual Function mode. Dual Function mode allows you to configure the module for either Access Gateway or

Standard Full-Fabric Switch mode. For more information, refer to “Dual function and access gateway configurations” on page 1.

This chapter provides configuration procedures that use SAN I/O Module Command Line Interface

(CLI) and the Web Tools application. For details refer to the Web Tools Administrator’s Guide,

Access Gateway Administrator’s Guide, and Fabric OS Command Reference Manual. If the same operation can be performed using the Blade Server Enclosure’s Chassis Management Controller

(CMC) application, use that application instead.

Items required

The following items are required for configuring and connecting the SAN I/O Module for use in a network and fabric:

• The SAN I/O Module installed in a Blade Server Enclosure. For instructions, refer to the steps on installing an I/O module in the Hardware Owner’s Manual for the Blade Server Enclosure.

• If required, management workstation (computer) that has a terminal emulator (such as

HyperTerminal) or a keyboard, video, and mouse (KVM) device. Note that this is only required if not changing the SAN I/O Module IP address through the Blade Server Enclosure GUI or CLI management programs.

• An unused IP address and corresponding subnet mask and gateway address unless DHCP is used.

• If required, a serial cable to connect to the SAN I/O Module serial console port. Note that this is only required if not changing the SAN I/O Module IP address through the Blade Server

Enclosure GUI or CLI management programs.

• SFP transceivers and compatible fibre cables, as required.

• Access to an FTP server for backing up the SAN I/O Module configuration.

• Access to these publications:

• Blade Server Enclosure Hardware Owner’s Manual

• Blade Server Enclosure Configuration Guide

• Fabric OS Command Reference Manual

SAN TECH NOTE – Preparing to Install the Brocade Access Gateway

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

9

2

Modify the SAN I/O Module IP address

• Access Gateway Administrator’s Guide

• Web Tools Administrator’s Guide

Modify the SAN I/O Module IP address

By default, the IP address for the SAN I/O Module is configured as 10.77.77.77 with a default

Ethernet subnetmask of 255.255.255.0.

Reset the IP address using three methods. If the IP values are set using either of these methods, the IP values are stored on the SAN I/O Module.

• SAN I/O Module Command Line Interface (CLI).

• Blade Server Enclosure CMC CLI.

• Blade Server Enclosure CMC graphical user interface (GUI).

ATTENTION

Do not connect the SAN I/O Module to the internal network until the IP address is correctly set for your Ethernet network requirements.

NOTE

It is recommended that you set the IP address using the Blade Server Enclosure CMC GUI application because this enables centralized management of the SAN I/O Module.

Using the SAN I/O Module CLI to set the IP address

Use the following tasks to change the IP address on the SAN I/O Module using the Module’s CLI.

Task 1: Establish a terminal session with the SAN I/O Module

Use these steps to establish a terminal emulation session between the SAN I/O Module and a

Blade Server Enclosure management workstation used for managing the I/O Module. Once this session is established, you can log into the Module and use its CLI commands to manage the module.

1. Connect a serial cable between the serial console port on the SAN I/O Module and a Blade

Server Enclosure management workstation that can establish a terminal emulation session with the SAN I/O Module. For instructions, refer to Configuration Guide for your Blade Server enclosure.

2. Disable any serial communication programs that are running on the workstation.

3. Using a terminal emulator application (such as HyperTerminal on a PC or TERM in a LINUX or

UNIX environment), establish a terminal session to the SAN I/O Module from the management workstation. You will use this connection if you want to reset the module’s IP address using CLI commands and perform other configuration tasks.

For Windows 95, 98, 2000, XP or NT a. Click Start and select Programs -> Accessories -> Communications.

b. Select Hyperterminal and enter a name for the connection.

10 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Modify the SAN I/O Module IP address

2 c. From the Hyperterminal window, click the Connect drop-down menu and select an available COM port.

d. Click OK.

e. From the COM Port Properties window, select the following configuration values:

Bits per second: 9600

Databits: 8

Parity: None

Stop bits: 1

Flow Control: None

For LINUX or UNIX a. Enter the following at the command prompt: tip /dev/ttyb -9600 b. When the terminal application stops reporting information, press Enter to display the login prompt.

c. Log in using the default administrative account

Login: admin

Password: password d. When prompted either change the administrative password, or press Ctrl-C to bypass.

Task 2: Changing the IP address

1. Verify that the SAN I/O Module has completed POST. When POST is complete, the port status and SAN I/O Module power and status LEDs return to a standard healthy state.

2. Enter the CLI ipAddrSet command.

Follow on-screen instructions and supply the correct information, as shown in the following example.

switch:admin> ipaddrset

Ethernet IP Address [10.77.77.77]:10.32.53.47

Ethernet Subnetmask [255.255.255.0]:255.255.240.0

Fibre Channel IP Addresss [none]:

Fibre Channel Subnetmask [none]:

Gateway IP Address [0.0.0.0]:10.32.48.1

DHCP [Off]:

IP address is being changed...Done.

3. Enter ipAddrShow at the prompt to verify that the address was correctly set.

Using the CMC CLI to set the IP address

Use the following steps to connect modify the SAN I/O Module IP address through the CMC CLI.

1. Establish a Telnet session to the CMC CLI.

2. At the command prompt, type connect switch-x where x is the bay where the SAN I/O Module is installed. For example, switch-x can be:

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

11

2

Modify the SAN I/O Module IP address

• Switch-3 for SAN I/O Module installed in bay B1.

• Switch-4 for SAN I/O Module installed in bay B2.

• Switch-5 for SAN I/O Module installed in bay C1.

• Switch-6 for SAN I/O module installed in bay C2.

3. At the login prompt, log in to the SAN I/O Module. The default user name is “admin” and the password is “password”.

4. Use the appropriate CLI commands to change the IP address of the selected SAN I/O module.

Refer to your Blade Server Enclosure CLI documentation.

Using the CMC GUI to set the IP address

To change the IP address, use the following steps:

1. Open the CMC application’s Setup tab.

2. Enter the new information in the IP Address, Subnet Mask, and Gateway fields as appropriate and click Apply.

3. To enable DHCP, select DHCP Enabled and click Apply.

FIGURE 4 CMC Setup Tab

12

NOTE

Refer to the documentation for the CMC GUI application for additional detail.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Connecting the SAN I/O Module to the Ethernet network

2

Connecting the SAN I/O Module to the Ethernet network

Once you have successfully set the appropriate IP address of the SAN I/O Module, you can establish an Ethernet connection through the Chassis Management Controller (CMC) to a remote management workstation for any additional configuration. The management workstation must be on the same Ethernet subnet as the CMC.

NOTE

Ensure that the SAN I/O Module is not being modified from any other connection until configuration is complete.

Connecting the SAN I/O Module to the fabric

NOTE

Refer to “Cabling guidelines” on page 8 before beginning the following procedure.

Before beginning the following steps, determine whether the SAN I/O Module is in Access Gateway or Full Fabric Switch mode. This affects the configuration process. Using the SAN I/O Module CLI, you can enter the ag ––modeShow command to determine the current operating mode.

1. If the SAN I/O Module is in Full Fabric Switch mode, continue with step 2

and

step 3

. If the

Module is in Access Gateway Mode, go on to

step 4

.

2. Log onto the SAN I/O Module through a Telnet connection, using the admin account.

3. Modify the domain ID if required using SAN I/O Module CLI commands.

The default domain ID is 1. If the SAN I/O Module is not powered on until after it is connected to the fabric and the default domain ID is already in use, the domain ID for the new SAN I/O

Module is automatically reset to a unique value. If the SAN I/O Module is connected to the fabric after it has been powered on and the default domain ID is already in use, the fabric segments.

To find the domain IDs that are currently in use, run the fabricShow command on another SAN

I/O Module in the fabric. Identify an unused domain ID: a. Disable the SAN I/O Module being configured using the switchDisable command.

b. Enter the configure command.

The command prompts display sequentially. Enter a new value or press Enter to accept each default value. The SAN I/O Module now has a unique domain ID and can join the fabric. Following is an example of command output.

SW48000_155:root> configure

Data field size: (256..2112) [2112]

Sequence Level Switching: (0..1) [0]

Disable Device Probing: (0..1) [0]

Suppress Class F Traffic: (0..1) [0]

Switch PID Format: (1..2) [1]Configure...

Fabric parameters (yes, y, no, n): [no] y

Domain: (1..239) [1] 155

R_A_TOV: (4000..120000) [10000]

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

13

14

2

Connecting the SAN I/O Module to the fabric

E_D_TOV: (1000..5000) [2000]

WAN_TOV: (0..30000) [0]

MAX_HOPS: (7..19) [7]

Per-frame Route Priority: (0..1) [0]

Long Distance Fabric: (0..1) [0]

BB credit: (1..27) [16]

Insistent Domain ID Mode (yes, y, no, n): [no]

Virtual Channel parameters (yes, y, no, n): [no]

F-Port login parameters (yes, y, no, n): [no]

Zoning Operation parameters (yes, y, no, n): [no]

RSCN Transmission Mode (yes, y, no, n): [no]

Arbitrated Loop parameters (yes, y, no, n): [no]

System services (yes, y, no, n): [no]

Portlog events enable (yes, y, no, n): [no]

ssl attributes (yes, y, no, n): [no]

http attributes (yes, y, no, n): [no]

snmp attributes (yes, y, no, n): [no]

rpcd attributes (yes, y, no, n): [no]

cfgload attributes (yes, y, no, n): [no]

webtools attributes (yes, y, no, n): [no]

System (yes, y, no, n): [no]

WARNING: The domain ID will be changed. The port level zoning may be affected c. Re-enable the SAN I/O Module by entering the switchEnable command.

NOTE

It could take a short time (typically a few seconds, but sometimes a little longer) for the newly added SAN I/O Module to appear in the fabric display with its newly assigned domain ID.

4. If you need to install SFP transceivers, install them in the external Fibre Channel ports as required.

a. Remove the dust plugs from the ports to be used.

b. If necessary, remove the end caps from the SFP.

c. Orient the transceiver correctly and insert it into a port until it is firmly seated and the latching mechanism clicks.

For instructions specific to the type of transceiver, refer to the transceiver manufacturer’s documentation.

d. Repeat substeps a, b, and c for the remaining ports, as required.

5. Connect the cables to the transceivers.

The transceivers are keyed to ensure correct orientation. If a transceiver does not install easily, ensure that it is correctly oriented and that the end caps have been removed. The cables used in trunking groups must meet specific requirements. For a list of these requirements, see the

Fabric OS Administrator’s Guide.

ATTENTION

A cable should not be bent to a radius less than 5.08 cm (2 inches) under full tensile load and 3.048 cm (1.2 inches) with no tensile load.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Changing from Fabric Switch mode to Access Gateway mode

2

Tie wraps are not recommended for optical cables because they are easily overtightened.

a. Orient a cable connector so that the key (the ridge on one side of connector) aligns with the slot in the transceiver. b. Insert the cable into the transceiver until the latching mechanism clicks. For instructions specific to cable type, refer to the cable manufacturer’s documentation.

c. Repeat for the remaining transceivers as required.

6. Check the LEDs to verify that all components are functional.

For information about LED patterns, see the “Interpreting LED activity” on page 22.

7. Verify the correct operation of the SAN I/O Module by typing the switchShow command from the workstation.

This command provides information about SAN I/O Module and port status.

8. Verify the correct operation of the SAN I/O Module in the fabric by typing the fabricShow CLI command from the workstation.

9. Back up the SAN I/O Module configuration to an FTP server by typing the configUpload command and following the prompts.

This command uploads the SAN I/O Module configuration to the server, making it available for downloading to a replacement SAN I/O Module if necessary. Brocade recommends backing up the configuration on a regular basis to ensure that a complete configuration is available for downloading to a replacement SAN I/O Module.

For specific instructions about how to back up the configuration, see the Fabric OS

Administrator’s Guide. The switchShow, fabricShow, and configUpload commands are described in detail in the Fabric OS Command Reference Manual.

Changing from Fabric Switch mode to Access Gateway mode

If your SAN I/O Module can run in Dual Function mode and is currently configured in Standard Full

Fabric Switch mode you can enable Access Gateway mode using the following instructions. You can log into the SAN I/O Module and enable Access Gateway mode using either Web Tools or the SAN

I/O Module command line interface (CLI).

Notes

• The module ships from the factory in either Access Gateway or Dual Function mode. In Dual

Function mode, you can configure the module for either Access Gateway Mode or Full Fabric

Switch mode without an additional license. The module is enabled for Full Fabric Switch mode as the default. If the module comes configured in Access Gateway mode, you will need an upgrade license to change to Dual Function mode.

• Enabling Access Gateway mode is a disruptive process because the switch is disabled and rebooted.Once you enable the SAN I/O Module in Access Gateway mode, only a limited subset of Fabric OS commands are available and all fabric-related service requests are forwarded to the fabric switches. See the Access Gateway Administrator’s Guide for more information.

• When you enable Access Gateway mode some fabric information is erased, such as the zone and security databases. To recover the information save the switch configuration before enabling Access Gateway mode.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

15

16

2

Changing from Fabric Switch mode to Access Gateway mode

Web Tools

Complete the following steps to enable Access Gateway mode using Web Tools.

1. From the management console, open a Web browser.

2. Enter the IP address of the SAN I/O Module into the Address field of the Web browser.

See the Web Tools Administrator’s Guide for more information on using Web Tools.

3. Log into Web Tools using the default administrative account.

Login: admin

Password: password

4. From the Fabric Tree, select the SAN I/O Module.

The selected SAN I/O Module appears in the Switch View.

5. Click the Switch Admin button in the WebTools Manage taskbox.

The Switch Administration window opens.

NOTE

You should save the configuration file if you are converting an SAN I/O Module to Access Gateway mode. To save your current configuration, click the Show Advanced Mode button in the top right-hand corner of the Switch Administration window. Select the Configure tab, then select the

Upload/Download tab. Enter the relevant information to upload the configuration file.

6. From the Switch Status section, click Disable.

7. From the Access Gateway Mode section, click Enable.

8. Click Apply.

9. When prompted, click Yes to restart the SAN I/O Module in Access Gateway mode.

The current Web Tools session closes; relaunch Web Tools after the SAN I/O Module reboots.

Command Line Interface

Complete the following steps to enable Access Gateway mode using the CLI.

1. Log in using the default administrative account.

Login: admin

Password: password

2. Enter the following command to disable Full Fabric Switch mode.

switchDisable

3. Enter the following command to save the current configuration on the SAN I/O Module.

This command is optional and is only required if you are converting an existing SAN I/O Module to Access Gateway mode.

configUpload Save

4. Enter the following command to enable Access Gateway mode: ag ––modeEnable

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Changing from Access Gateway Mode to Fabric Switch Mode

2

The SAN I/O Module automatically reboots and comes back online in Access Gateway mode using a factory default F_Port to N_Port mapping. You can enter the ag ––modeShow command to ensure that the module is in Access Gateway mode. See the Access Gateway

Administrator’s Guide for more detailed configuration information.

You can also enter the ag ––mapshow command to display the F_Port to N_Port mapping.

Enter ag ––help command to display a list of all Access Gateway actions.

Changing from Access Gateway Mode to Fabric Switch Mode

If your SAN I/O Module can run in Dual Function mode and is currently configured in Access

Gateway mode, you can enable the module for Standard Full Fabric Switch mode by disabling

Access Gateway mode. When you do this, the module automatically reboots in Fabric Switch mode.

For complete instructions on disabling Access Gateway Mode using the CLI and joining the switch to the fabric, refer to the “Disabling Access Gateway Mode” section in the Access Gateway

Administrator’s Guide.

Notes

• A license is required for Dual Function Mode, which allows you to switch between Access

Gateway and Standard Full Fabric Switch Mode. If your SAN I/O Module was shipped in Access

Gateway Mode, you cannot switch to Fabric Switch Mode without this license.

You can also use the CLI licenseshow command to determine whether the module is Dual

Function (Switch), or Access Gateway. This command displays current license keys, along with a list of licensed products enabled by these keys. A Dual Function (Switch) module should have a “Fabric license” in the command output

• Disabling Access Gateway mode is disruptive because the switch is disabled and rebooted.

Always back up the current configuration before enabling or disabling Access Gateway mode.

Enabling Access Gateway mode clears the security and zone databases. Disabling Access

Gateway mode clears the F_Port to N_Port mapping.

Activating Ports on Demand (POD)

Ports on Demand (POD) licensing allows you to enable up to 24 ports from the initial 12 ports. Add optional POD licenses using either Brocade Web Tools or a Telnet connection; do not use the Blade

Server Enclosure CMC software.

Ports on Demand is ready to be unlocked in the SAN I/O Module firmware. A POD license might be supplied with SAN I/O Module software, or you can purchase the license separately from your SAN

I/O Module vendor, who will provide you with a key to unlock it.

Once you have installed the license keys, you must enable the ports. You can do so without disrupting SAN I/O Module operation, or alternatively, you can disable and re-enable the SAN I/O

Module to activate all ports.

If you remove a POD License, ports that were enabled by that license are disabled.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

17

2

Connecting to the SAN I/O Module Using Web Tools

Activating ports with a POD license

You can activate ports with a POD license while the SAN I/O Module is connected to existing SANs or before connecting to an existing SAN.

For SAN I/O Modules already connected to existing storage networks:

1. Add the POD license using Web Tools or CLI.

2. Enable each newly licensed port using Web Tools or CLI.

NOTE

This method is non-disruptive to existing servers and storage connecting to SAN I/O Module.

For new SAN I/O Module installations, perform the following before connecting to an existing SAN.

ATTENTION

Do not use this method if the SAN I/O Module is operating in an existing SAN because traffic will be disrupted.

1. Disable the SAN I/O Module.

NOTE

If Secure Fabric OS (Secure FOS) is enabled, you cannot use Telnet or SSH to disable the module. For details about using Web Tools, refer to the Web Tools Administrator’s Guide. For details about the CLI, see the Fabric OS Command Reference Manual.

2. Add the POD license using Web Tools or the CLI.

3. Enable the SAN I/O Module using Web Tools or CLI. When the SAN I/O Module is enabled, the newly-added POD ports are also enabled.

Connecting to the SAN I/O Module Using Web Tools

Complete the following steps to connect to the SAN I/O Module using Web Tools.

1. On the management console, open a Web browser such as Internet Explorer.

The Web browser must be connected to the same network as the SAN I/O Module.

2. Enter the IP address of the SAN I/O Module in the address field and press Enter.

For more information about using Web Tools, see the Web Tools Administrator’s Guide.

18 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Operating the SAN I/O Module

Chapter

3

This chapter describes the operation and interoperability of the SAN I/O Module.

Interoperability

The SAN I/O Module supports interoperability for the following functions:

• link initialization

• principal SAN I/O Module selection

• soft WWN zoning

• SNMP facilities

• routing (FSPF)

• Simple Name Service

• state change notification

• translative mode (private target support on fabrics)

• trunking (between two Brocade switches)

• Advanced Performance Monitoring

Port negotiation

The SAN I/O Module has been designed to be highly interoperable. It supports 1 Gbit/sec, 2

Gbit/sec, and 4 Gbit/sec transmit and receive rates with autonegotiation. The actual data signaling rate used on a port is automatically sensed and set to the rate supported by the device or devices attached to the port.

If the SAN I/O Module is connected to a device, but is unable to negotiate the signaling rate, the operator can manually set the speed of each port through the management interfaces.

The SAN I/O Module is compliant with current Fibre Channel standards, including most current-generation switch N_Ports, NL_Ports, and E_Ports as well as host adapters, Redundant

Array of Independent Disks (RAID) storage devices, hubs, Fibre-SCSI bridge devices, and older switch families.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

19

3

Accessing the SAN I/O Module

Operating system support

Brocade Fabric OS has no specific host OS dependencies. The Fabric OS in the switches allows for any Fibre Channel-compliant device to attach to switches as long as it conforms to the standards for device login, name service, and related Fibre Channel features. The operating systems listed in

Table 2

are for the host machine running Brocade management applications outside the Fabric OS, such as Fabric Manager and Enterprise Fabric Connectivity Manager (EFCM). For the latest information on operating system support for these applications, refer to the latest released versions of Fabric Manager and EFCM documentation.

TABLE 2 Supported Operating Systems - Fabric Manager

Operating System Version

Windows 2000

Windows 2003

Windows XP

Solaris

Linux Red Hat Enterprise

N/A

N/A

N/A

8, 9, 10

AS 3.0, AS 4.0

TABLE 3 Supported Operating Systems - EFCM

Operating System Version

Windows 2000

Windows 2003

Windows XP

Solaris

Linux Red Hat

Linux Red Hat Enterprise

SuSe Linux Professional Edition version 9.2

SP4

SP1

XP2

9, 10

9.0

ES 3.0, ES 4.0

9.2, 9.3

Accessing the SAN I/O Module

The SAN I/O Module is managed as a single element. It has a single IP address and appears as a separate entity to the Telnet protocol and the Simple Network Management Protocol (SNMP).

When SNMP devices send SNMP messages to a management console running SAN management software, the information is stored in a Management Information Base (MIB). The Brocade 4424

Fabric OS 4.4.1 supports the FibreAlliance Fibre Channel Management (FCMGMT) MIBs, allowing the provision of needed information to a SAN administrator.

In addition, the Brocade Fabric Access Layer (API) and the Storage Management Initiative (SMI) provide facilities for the discovery and management of physical and logical elements in a SAN.

Using the Fabric Access interface to the Fabric OS, a client application can retrieve information and modify the configuration of Brocade switches in the fabric.

20 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Interpreting POST results

3

Secure Telnet access is available using Secure Shell (SSH), a network security protocol for secure remote login and other secure network services over an insecure network.

Brocade Web Tools management is available through a secure browser using Secure Sockets Layer

(SSL). The SSL security protocol provides data encryption, server authentication, message integrity, and optional client authentication for a TCP/IP connection. Because SSL is built into all major browsers and Web servers, installing a digital certificate enables the SSL capabilities.

Interpreting POST results

The power-on self test (POST) system check is performed each time the SAN I/O Module is powered on, rebooted, or reset.

Example POST Output

POST1: Started running Tue Nov 9 20:27:57 GMT 2004

POST1: Test #1 - Running turboramtest

POST1: Test #2 - Running centralmemorytest

POST1: Test #3 - Running cmitest

POST2: Running diagshow

POST1: Script PASSED with exit status of 0 Tue Nov 9 20:28:10 GMT 2004 took

(0:

0:13)

POST2: Started running Tue Nov 9 20:28:12 GMT 2004

POST2: Test #1 - Running camtest

POST2: Test #2 - Running txdpath

POST2: Test #3 - Running spinsilk (SERDES)

POST2: Running diagshow

POST2: Script PASSED with exit status of 0 Tue Nov 9 20:29:11 GMT 2006 took

(0:

0:59)

Initializing Ports ....

Port Initialization Completed

Enabling switch...

During POST, the LEDs are activated in various indicator patterns.

Perform the following steps to determine POST completion status.

1. Verify that the LEDs on the SAN I/O Module indicate a healthy SAN I/O Module. LED patterns are described in

“Interpreting LED activity,” next.

If one or more LEDs do not display a healthy state, verify that the LEDs are not set to beacon.

Use the SAN I/O Module CLI switchShow command or Web Tools to verify the LED state. For information about how to turn beaconing on and off, see the Fabric OS Administrator’s Guide or the Web Tools Administrator’s Guide.

2. Use the Blade Server Enclosure’s Chassis Management Controller (CMC) GUI to verify that the

SAN I/O Module is working correctly.

For details, refer to the Hardware Owner’s Manual for the Blade Server Enclosure.

3. Review the system log for errors.

Any errors detected during POST are written to the system log. Access this log through the

Module’s CLI errShow command. For information about this command, see the Fabric OS

Command Reference Manual. For information about error messages, see the Fabric OS

System Error Message Reference Manual.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

21

3

Interpreting LED activity

Interpreting LED activity

Each SAN I/O Module uses LEDs to indicate status. These LEDs are shown in Figure 5 .

FIGURE 5 LED Locations

1 2

7 8

22

3 4 5 6

TABLE 4

Location

1

Key to Figure 5

Indicator

FC (external) port status

Color green/amber

2 FC port x speed

3 (status icon) and 4 (LED) module status green/amber green/amber

Operation

Note: LED meanings are not valid during boot, diagnostics, or POST.

Green:

Off (dark): No signal carrier or unlicensed.

Steady: Online normal active port but no port activity.

Flickering: normal active port (I/O activity).

Slow blink: Online but segmented.

Fast blink: Internal loopback.

Amber

Steady: Signal present but not online.

Slow blink or flash: Disabled port (less than two second interval).

Fast (rapid) blink or flash: Error or fault with port (less than

1/2 second interval).

Amber on: 4 Gbit/sec FC

Green on: 2 Gbit/sec FC

Both off (dark): 1 Gbit/sec FC

Off:

SAN I/O Module is off or power supplies for the Blade Server or onboard DCC have failed.

Green:

No errors and all ports are ready for use.

Amber:

Steady: Boot-up state, port(s) offline, or in reset state.

Blinking (green/amber): One or more environmental ranges are exceeded, or error log contains diagnostic error messages.

Note: The LED might blink during testing.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Removing and replacing the SAN I/O Module

3

TABLE 4

Location

5 (LED) and 6

(icon)

7 (LED) and 8

(icon)

Key to Figure 5 (Continued)

Indicator module power

Color (Continued) Operation (Continued) green server management blue/amber

Off:

SAN I/O Module is off or power supplies for the Blade Server

Enclosure or onboard DCC have failed.

Green: Normal operation and power supply is functioning. properly. Power is supplied by the Blade Server Enclosure.

Controlled by the Blade Server Enclosure's CMC. For details, refer to the Hardware Owner’s Manual for Blade Server

Enclosure.

Locating the serial number

Before contacting service support, be sure to obtain the module’s serial number. Use one of these methods to locate the number:

• Use the CLI and enter the ChassisShow command. The SAN I/O Module serial number is displayed along with other data.

Locate the serial number on the label attached to the SAN I/O Module. Refer to Figure 3 on page 5 for location.

Removing and replacing the SAN I/O Module

Complete the following steps to remove and replace a failed SAN I/O Module.

NOTE

Before beginning this procedure, ensure that you have a replacement SAN I/O Module or filler panel available because you do not want to leave the slot on the Blade Server Enclosure open for an extended period of time. The slot must be filled with either a replacement SAN I/O Module or a filler panel to maintain proper airflow.

1. Back up the SAN I/O Module configuration to an FTP server by using the Module’s configUpload CLI command and following the prompts.

This command uploads the SAN I/O Module configuration to the server, making it available for downloading to a replacement SAN I/O Module if necessary. It is recommended to back up the configuration on a regular basis to ensure that a complete configuration is available for downloading to a replacement SAN I/O Module.

2. Stop all SAN activity requiring the ports used by the SAN I/O Module.

For details about port management, refer to your Blade Server Enclosure Hardware Owner’s

Manual. Verify that there is no activity by viewing the SAN I/O Module LEDs. For details about

LED activity on the SAN I/O Module, see

“Interpreting LED activity” on page 22.

3. Remove all cables from the SFP modules.

4. Remove the SFP modules according to the manufacturer’s instructions.

Figure 6 on page 24 details the generic process for removing an SFP from a port.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

23

3

Removing and replacing the SAN I/O Module

FIGURE 6 Removing an SFP from a Port

Cable

Release

1

SFP

Bale

SFP

3

4

2

5. Refer to the Hardware Owner’s Manual for the Blade Server Enclosure to remove and replace the SAN I/O module from the enclosure.

.

ATTENTION

If you are not replacing the SAN I/O Module, use a filler panel to fill the empty slot to maintain proper air flow. Do not leave the slot empty.

24 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

SAN I/O Module specifications

Appendix

A

This appendix provides product specifications and regulatory compliance as a handy reference.

Access Gateway Mode default port mapping

The 4424 SAN I/O Module can contain 24 total ports. Of these, F_Ports are ports 1-16 and N_Ports are ports 0 and 17-23.

In Access Gateway mode, the SAN I/O Module F_Ports are mapped to N_Ports. This following lists the factory-default F_Port to N_Port mapping for Access Gateway mode. Since the SAN I/O Module is shipped with Dynamic Ports on Demand (DPOD) enabled, any out of the 24 ports can be enabled. Therefore this mapping applies for 12 active ports or, if POD licensing is enabled, for 24 ports. For more information on changing port mapping and managing ports in Access Gateway

Mode, refer to the Access Gateway Administrator’s Guide.

• 17-20 as N_Port with failover enabled, failback enabled

• 0, 21-23 as N_Port with failover enabled, failback enabled

• 1, 2 mapped to 17

• 3, 4 mapped to 18

• 5, 6 mapped to 19·

• 7, 8 mapped to 20

• 9, 10 mapped to 21·

• 11, 12 mapped to 22·

• 13, 14 mapped to 23·

• 15, 16 mapped to 0

Processor and memory specifications

The processor and memory installed in the SAN I/O Module are shown in Table 5

.

TABLE 5

Memory Type

Memory Specifications

Value

PowerPC 440GP processor

SDRAM

Boot flash

Compact flash

333 MHz

256 MB - for system memory at 64 bits wide with

8 ECC bits

4 MB

256 MB

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

25

A

Weight and physical dimensions

Weight and physical dimensions

Table 6

lists the weight and physical dimensions of the SAN I/O Module.

TABLE 6

Dimension

SAN I/O Module Specifications

Measurements

Height

Width

Depth

Weight

1.24 in (31.45 mm)

10.74 in (272.75 mm)

12.08 in (306.74 mm)

3.84 (1.74 kg) — without media

Facility requirements

The information in

Table 7

shows the operating and non-operating limitations of the Brocade 4424

SAN I/O Module.

TABLE 7

Condition

Environmental Requirements

Operating Non-operating

Temperature

Humidity

Altitude

Shock

Vibration

Air flow

32°F to 122°F (0°C to 50°C)

10% to 95%, non-condensing at

84.2°F (29°C)

Up to 10,000 ft (3,048 m)

20G for 11ms

Sine sweep: 1.0G at 5-500-5 Hz for 15 minutes

Random: 0.5G at 5-500 Hz for 60 minutes

86 °F (30°C) Ambient: Approx. 3CFM

104°F (40°C) Ambient: Approx.

9CFM

-45.4°F to 163.4°F (-43°C to 73°C)

5% to 95%, non-condensing at

100.4 °F (38°C)

40,000 ft (12,192m)

33G for 11ms

Sine sweep; 2.4G at 5-500-5 Hz for 15 minutes

Random: 1.12G at 5-500 Hz for 30 minutes

None required

26 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Architectural specification

A

Architectural specification

The SAN I/O Module meets the specifications shown in Table 8 .

TABLE 8 Architecture

Feature

Scalability

Certified maximum

Performance

Description

Full-fabric architecture with maximum of 239 switches

32 switches, 7 hops

1.063 Gbit/sec line speed, full duplex

2.125 Gbit/sec line speed, full duplex

<2.1 µsec with no contention Fabric latency

(Fabric Switch Mode only)

Maximum frame size

Class of service

Port types

Fabric services

(Fabric Switch Mode only)

2112-byte payload

Class 2

Class 3

Class F (interswitch frames)

FL_Port

F_Port

E_Port

N_Port

Simple Name Server, Registered State Change Notification

Supported HBAs

For a complete list of interoperable hardware, visit the Brocade Connect Web site at: http://www.brocadeconnect.com

and follow the links to the latest compatibility matrix. From the main page, select Technical

Resource Center, then Documentation Library. Finally, choose Compatibility and Scalability

Information.

For more information and a list of supported HBAs, refer to your Dell PowerEdge documentation.

Fibre Channel standards compliance

The SAN I/O Module switch meets or exceeds the Fibre Channel standards for compliance, performance, and feature capabilities as defined in the Brocade standards compliance list. This information is available at: http://www.brocade.com/products/interop/standards_compliance.jsp

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

27

A

Regulatory compliance

Regulatory compliance

This section describes the regulatory compliance requirements for the Brocade 4424.

FCC warning (US only)

This equipment has been tested and complies with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.

MIC Statement (Republic of Korea)

VCCI statement (Japan)

This is a Class A product based on the standard of the Voluntary Control Council for Interference by

Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance might arise. When such trouble occurs, the user might be required to take corrective actions.

28 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

BSMI statement (Republic of Taiwan)

Regulatory compliance

A

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

29

30

A

Regulatory compliance

CE statement

ATTENTION

This is a Class A product. In a domestic environment, this product might cause radio interference, and the user might be required to take corrective measures.

The standards compliance label on the Switch contains the CE mark which indicates that this system conforms to the provisions of the following European Council directives, laws, and standards:

• Electromagnetic Compatibility (EMC) Directive 89/336/EEC and the Complementary Directives

92/31/EEC and 93/68/EEC

• Low Voltage Directive (LVD) 73/23/EEC and the Complementary Directive 93/68/EEC

• EN50082-2/EN55024:1998 (European Immunity Requirements)

• EN61000-3-2/JEIDA (European and Japanese Harmonics Spec)

• EN61000-3-3

Canadian requirements

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing

Equipment Regulations, ICES-003 Class A.

Laser compliance

This equipment contains Class 1 laser products and complies with FDA Radiation Performance

Standards, 21 CFR Subchapter I and the international laser safety standard IEC 825-2.

CAUTION

Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter

I, and with IEC 825-2. Optical products that do not comply with these standards might emit light that is hazardous to the eyes.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Environmental regulation compliance

A

Environmental regulation compliance

This section describes the China ROHS environmental regulatory compliance requirements for the

SAN I/O Module.

China RoHS

The contents included in this section are per the requirements of the People's Republic of China-

Management Methods for Controlling Pollution by Electronic Information products.

䙉ᅜ⦃๗⊩㾘

Ё೑

RoHS ᴀ㡖Ёࣙ৿ⱘݙᆍ䛑䙉ᅜњЁढҎ⇥݅੠೑lj⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩NJⱘ

㽕∖DŽ

Environmental Protection Use Period (EPUP) Disclaimer

In no event do the EPUP logos shown on the product and FRU's alter or expand that warranty that

Brocade provides with respect to its products as set forth in the applicable contract between

Brocade and its customer. Brocade hereby disclaims all other warranties and representations with respect to the information contained on this CD including the implied warranties of merchantability, fitness for a particular purposes and non-infringement.

The EPUP assumes that the product will be used under normal conditions in accordance with the operating manual of the product.

⦃ֱՓ⫼ᳳ䰤 (EPUP) ܡ䋷ໄᯢ˖

EPUP ᷛᖫϡӮߎ⦄೼ѻક੠ FRU ⱘᬍ㺙ѻકЁˈгϡӮᇍ Brocade

᠔ᦤկⱘⳌ݇ѻકֱׂᴵℒ˄䆹ֱׂᴵℒ೼ Brocade

ঞ݊ᅶ᠋䯈䖒៤ⱘ䗖⫼ড়ৠЁ߫ߎ˅䖯㸠๲㸹DŽᇍѢℸ CD

Ϟࣙ৿ⱘⳌֵ݇ᙃˈབ䗖䫔ᗻǃ䩜ᇍ⡍ᅮ⫼䗨ⱘ䗖⫼ᗻ੠䴲։ᴗᗻⱘᱫ⼎ֱ䆕ˈBr ocade ೼ℸ䚥䞡ໄᯢᴀ݀ৌᇍѢϢϞ䗄ֵᙃⳌ݇ⱘ᠔᳝݊Ҫֱ䆕੠䰜䗄ὖϡ䋳䋷DŽ

EPUP ؛䆒೼Āѻક᪡԰᠟ݠāЁ⊼ᯢⱘᐌ㾘ᴵӊϟՓ⫼䆹ѻકDŽ

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

31

32

A

Environmental regulation compliance

TS/HS Dual Language Sheet

In accordance with China's Management Measures on the Control of Pollution caused by Electronic

Information products (Decree No. 39 by the Ministry of Information Industry), the following information is provided regarding the names and concentration level of Hazardous substances (HS) which may be contained in this product.

China ROHS Hazardous Substances/Toxic Substances (HS/TS) Concentration Chart

Name of the

Component

Hazardous/Toxic Substance/Elements

Lead (PB) Mercury

(Hg)

Cadium

(CD)

O O

Hexavalent

Chromium

(CR6+)

O

Polybrominated

Biphenyl (PBB)

O

Polybrominated

Diphenyl Ether

(PBDE)

O Fibre Channel

Switch

PCBA cards

SFPs (optical cable connectors)

Sheet Metal

Mechanical brackets and

Slides

Software/

Documentation

CDs

X

X

X

X

X

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

X indicates that the concentration of such hazardous/toxic substance in all the units of homogeneous material of such component is higher than the SJ/T11363-2006 Requirements for

Concentration Limits.

O indicates that no such substances are used or that the concentration is within the aforementioned limits.

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Environmental regulation compliance

A

CHINA ROHS᳝ᆇ⠽䋼/᳝↦⠽䋼(HS/TS)䰤䞣߫㸼

᳝↦Ϣ᳝ᆇ⠽䋼៪ܗ㋴ⱘৡ⿄ঞ৿䞣 ḍ᥂Ё೑ⱘ<<⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩>>

(ֵᙃѻϮ䚼㄀39োҸ)ˈᴀ݀ৌᦤկҹϟ᳝݇ѻકЁৃ㛑৿᳝ⱘ᳝ᆇ⠽䋼(HS)ⱘৡ⿄ঞ৿䞣∈ᑇⱘ

ֵᙃDŽ

Џ㽕䚼ӊৡ⿄

ܝ㑸䗮䘧Ѹᤶᴎ

㒓䏃ᵓ䚼ӊ

SFP˄ܝ㑸᥹

༈˅

䩷䞥ӊ ᴎẄᬃᶊঞ⒥䔼

䕃ӊ/᭛ḷܝⲬ

X

O

˄PB˅

X

X

X

X

X

O

˄ Hg˅

O

O

O

O

O

O

˄

CD˅

O

O

O

O

O

O

᳝ᆇ/᳝↦⠽䋼៪ܗ㋴

݁Ӌ䫀

˄CR6+˅

O

O

O

O

O

O

㸼⼎᳾Փ⫼ℸ㉏⠽䋼៪݊৿䞣ԢѢϞ䗄䰤䞣㽕∖DŽ

໮⒈㘨㣃

˄PBB˅

O

O

O

O

O

O

໮⒈Ѡ㣃䝮

˅ PBDE˅

O

O

O

㸼⼎ℸ㉏䚼ӊݙৠ䋼ᴤ᭭Ёⱘ᳝ᆇ/᳝↦৿䞣催ѢSJ/T11363-2006ⱘ䰤䞣㽕∖DŽ

O

O

O

Regulatory certifications

Table 9

lists the safety and EMC (electromagnetic compatibility) specifications for which the Switch is certified.

TABLE 9

Country

Argentina

EMC certifications

Safety specification

IEC 60950-1:2001

IEC 60825-1:1993+A1+A2

Australia and New Zealand

Canada

China (power supply only)

CSA60950-1-03 1st Ed.

GB4943-1995

EMC specification

European Union

(Austria, Belgium, Cyprus, Czech

Republic, Denmark, Estonia,

Finland, France, Germany,

Greece, Hungary, Ireland, Italy,

Latvia, Lithuania, Luxembourg,

Malta, Poland, Portugal,

Slovakia, Slovenia, Spain,

Sweden, The Netherlands, and

United Kingdom)

EN 60950:92

+A1:93+A2:93+A3:95+A4:96+A11:97

73/23/EEC

EN60825-1:1994/A11, -2

TUV (Germany only)

IEC 60950+A1+A2+A3+A4+A11

(NEMKO CB Report) (Norway only)

International

Japan

IEC 60950+A1+A2+A3+A4+A11

IEC 60950+A1+A2+A3+A4+A11

EN55022:2006 Class A

CSA 108.8 Class A

GB9254-1998

GB17625.1

EN55022:2006 Class A

EN 55024 (Immunity)

EN 61000-4-2 Electrostatic Discharge

EN 61000-4-3 Radiated Fields

EN 61000-4-4 Electrical Fast Transients

EN 61000-4-5 Surge Voltage

EN 61000-4-6 Conducted Emissions

EN 61000-4-8 Magnetic Fields

EN 61000-4-11 Voltage Dips and Interruptions

EN 61000-3-2 Limits for Harmonic Current Emissions

EN 61000-3-3 Flicker

EN55022 Class A

EN55022 Class A

EN 61000-3-2 Harmonics (JEIDA Limits)

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

33

A

Environmental regulation compliance

TABLE 9 EMC certifications (Continued)

Country

Republic of Korea

Safety specification

Russia GOST R IEC 60950-2002

Taiwan (power supply only)

United States UL 60950-1 1st Ed.

EMC specification

KN24

KN22

GOST R 51318.22-99 (Class A)

GOST R 51318.24-99

GOST R 51317.3.2-99

GOST R 51317.3.3-99

CNS13438

EN55022 Class A

FCC Part 15, Subpart B (CFR title 47), Class A

34 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

Index

F

Fibre Channel Association , xi

A

access gateway mode 1

changing from fabric switch mode 15

default port mapping 25

activating POD ports 18

ag --help command 17 ag --mapshow command 17

ag --modeEnable command 16

air flow 26

architectural specifications 27

B

beacon 21

boot flash 25

Brocade applications supported 7

Brocade ISL Trunking 6

BSMI statement (Chinese) 29

C

cabling guidelines 8

Canadian requirements 30

China RoHS 31

commands

ag --help 17 ag --mapshow 17

ag --modeEnable 16

configUpload 15, 16

configure 13

connect 11 connect switch-x 11

errShow 21

fabricShow 15

ipAddrSet 11

licenseshow 2, 17

switchDisable 13, 16

switchShow 15, 21

compact flash 25

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

compatibility matrix 6

configUpload command 15, 16

configure command 13

connect command 11 connect switch-x command 11

console port 2, 3

D

dimensions 26

dual function mode 1

dynamic ports on demand 2

E

E_Ports 2

errShow command 21

F

F_Ports 2

Fabric OS vii, 20

fabric switch mode 1

Fabric Watch 7

fabricShow command 15

facility requirements 26

FCC warning (US only) 28

features 2, 7

Fibre Channel standards compliance 27

FL_Ports 2

flash 25

full fabric switch mode

available features 2

changing from access gateway mode 17

H

host OS 20

I

humidity 26

insertion arm 5, 6

Internet Explorer 18

interoperability 19

interpreting

LED activity 22

POST results 21

35

IP address

modify using CMC CLI 11

modify using CMC GUI 12

modify using module CLI 10 modifying default 10

ipAddrSet command 11

ISL 6

trunking 2, 6

trunking groups 6

K

kernel 25 kernel flash 25

L

labeling 6

laser compliance 30

LED 2, 21, 22

LED activity

interpreting 22

license key 17

licenseshow command 2, 17

LWL 2, 6

M

management tool 21

memory 25

MIC statement (Republic of Korea) 28

module status 3

N

nonport side of SAN I/O Module 5

O

operating requirements 26

operating system support 20

optional features 7 access gateway mode 7 full fabric switch mode 7

OS vii

P

performance monitoring 7

port management 23

port negotiation 19

port side of the SAN I/O Module 4

ports

activating POD ports 18

base ports for POD 4

POD 17

serial console 2

36

ports on demand (POD) 3

activating 17

activating ports 18

base ports 4

licensing 7, 18

POST 2, 21

results 21

processor 25

protective foam 7

R

regulatory certifications 33

regulatory compliance 28

removing and replacing 23

RJ-45 connector 2, 3

S

SAN I/O Module

accessing 20

cabling guidelines 8

characteristics 4

connecting to Ethernet 13 connecting to fabric 13

features 2

hardware description 4

physical dimensions and weight 26

removing and replacing 23 serial number 23

specifications 25

status 22

unpacking and installing 7

SDRAM 25

SEEPROM 25

serial cable 10

serial console port 2, 3

serial number 23

SFPs 2, 6

shipping package 7

shock 26 specifications 26

supported HBAs 27

supported SFP 6

switchDisable command 13, 16

switchShow command 15, 21

SWL 2, 6

T

temperature 26

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

terminal session with I/O module 10

trunking 6

U

unpacking the SAN I/O Module 7

V

VCCI statement 28

vibration 26

W

web browser 18

Web Tools 7, 18

using to connect SAN I/O Module 18

weight 26

Z

zoning 2, 7, 20

4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

37

38 4424 Blade Server SAN I/O Module Hardware Reference Manual

53-0000571-01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents