Specification Sheet Compact Fluorescent Program Start Series Lamp Operation escent Ballast Project:

Specification Sheet Compact Fluorescent Program Start Series Lamp Operation escent Ballast Project:
Specification Sheet
EP2/42CF/MV/2
Electronic Fluorescent Ballast
7/21/2014
Project:
2 Lamp
Standard Ballast Factor
Multi-volt
Catalog#:
Approved by:
Compact Fluorescent Program Start Series Lamp Operation
Lamp Type
No. Of
Lamps
Lamp
Watts
Line
Voltage
Ballast
Factor
Input
Watts
Input
Current
(amps)
Power
Factor
THD
Ballast
Efficacy
Factor
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
1
1
1
1
1
1
2
2
1
1
2
2
1+1
1+1
2
2
1
1
2
2
1
1
42
42
42
42
32
32
32
32
26
26
26
26
26
26
26
26
36
36
36
36
28
28
57
57
70
70
40
40
40
40
22
22
22/40
22/40
24
24
24
24
36
36
36
36
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
1.00
1.00
1.00
1.00
0.95
0.95
0.96
0.96
0.90
0.90
1.00
1.00
0.90
0.90
1.00
1.00
0.78
0.79
0.80
0.80
1.00
1.00
1.00
1.00
1.00
1.00
0.80
0.81
0.84
0.84
1.10
1.10
0.90
0.90
1.00
1.00
0.92
0.92
0.80
0.80
0.88
0.88
94
93
47
47
63
63
42
42
54
54
32
32
54
54
32
32
63
62
33
33
34
34
58
58
73
73
70
70
37
37
52
52
67
67
54
54
26
27
66
65
37
37
0.77
0.38
0.40
0.18
0.53
0.23
0.35
0.13
0.45
0.21
0.27
0.13
0.45
0.21
0.27
0.13
0.52
0.53
0.22
0.27
0.29
0.14
0.49
0.22
0.61
0.27
0.59
0.26
0.31
0.14
0.44
0.19
0.55
0.25
0.45
0.20
0.22
0.10
0.55
0.24
0.31
0.14
0.99
0.98
0.99
0.96
0.99
0.98
0.99
0.96
0.99
0.97
0.99
0.95
0.99
0.97
0.99
0.95
0.99
0.98
0.99
0.94
0.99
0.93
0.99
0.97
0.99
0.97
0.99
0.98
0.99
0.95
0.99
0.97
0.99
0.98
0.99
0.97
0.99
0.92
0.99
0.98
0.99
0.95
<10%
<10%
<10%
<10%
<10%
<12%
<10%
<12%
<10%
<12%
<10%
<12%
<10%
<12%
<10%
<12%
<10%
<10%
<10%
<15%
<10%
<10%
<10%
<12%
<10%
<12%
<10%
<10%
<10%
<15%
<10%
<12%
<10%
<10%
<10%
<10%
<10%
<15%
<10%
<10%
<10%
<12%
1.14
1.08
2.13
2.13
1.51
1.51
2.29
2.29
1.67
1.67
3.12
3.12
1.67
1.67
3.12
3.12
1.25
1.27
2.45
2.44
2.94
2.94
1.72
1.72
1.37
1.37
1.13
1.15
2.24
2.24
2.11
2.11
1.34
1.34
1.85
1.85
3.56
3.48
1.21
1.21
2.38
2.38
CF42TE*
CF32TE
CF26TE
CF26DE
CFM36W/2G10
CFS28W/GR10q
CFTR57/GX24q
CFTR70W/GX24q
FC12T5
FC9T5
FC9T5 + FC12T5
FT24W/2G11
FT36W/2G11
* Primary Lamp Design
• Specifications are subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652
www.HowardLightingProducts.com
EP2/42CF/MV/2
Electronic Fluorescent Ballast
Specification Sheet
Project:
2 Lamp
Standard Ballast Factor
Multi-volt
Catalog#:
Approved by:
Compact Fluorescent Program Start Series Lamp Operation
Lamp Type
FT39W/2G11
FT40W/2G11
FT55W/2G11
No. Of
Lamps
Lamp
Watts
Line
Voltage
Ballast
Factor
Input
Watts
Input
Current
(amps)
Power
Factor
THD
Ballast
Efficacy
Factor
2
2
1
1
2
2
1
1
1
1
39
39
39
39
40
40
40
40
55
55
120
277
120
277
120
277
120
277
120
277
0.95
0.95
1.00
1.00
0.95
0.95
1.00
1.00
0.71
0.72
82
82
45
45
82
82
45
45
43
44
0.69
0.30
0.37
0.17
0.63
0.30
0.37
0.17
0.36
0.16
0.99
0.98
0.99
0.96
0.99
0.98
0.99
0.96
0.99
0.96
<10%
<10%
<10%
<12%
<10%
<10%
<10%
<12%
<10%
<12%
1.16
1.16
2.22
2.22
1.16
1.16
2.22
2.22
1.65
1.66
Ballast Specifications
• Ballast shall have a five-year warranty with maximum case temperature of
70ºC or three-year warranty with maximum case temperature of 90ºC.
• Ballast shall be UL certified.
• Ballast shall be sound rated Class A.
• Ballast shall be Class P Type 1 Outdoor.
• Ballast shall have a Lamp Current Crest Factor of <1.7.
• Ballast shall withstand line transients as specified in ANSI C62.41.
• Ballast shall comply with the limits of FCC Part 18 Class B (Consumer).
• Ballast shall have a lamp operating frequency greater than 40KHz.
• Ballast shall have color-coded, dual entry poke-in connectors.
• Ballast shall ignite lamps within 900ms.
• Ballast shall have a 0ºF minimum lamp starting temperature for primary lamp(s).
• Ballast shall be Program Start.
• Ballast shall be Series Lamp Operation.
• Ballast shall have a minimum Power Factor of 97% for primary lamp operation.
• Ballast shall operate within a +/- 10% of the ballast specified line voltage at an
input frequency of 50Hz or 60Hz.
• Ballast shall have a maximum case hot spot temperature of 90ºC.
• Ballast shall have end of lamp life protection.
• Ballast shall have auto restart.
Dimensions
This ballast will operation the following lamps:
TOP VIEW
SIDE VIEW
4.2
4.5
1.38
TWIN (CFSE), 4 PIN
27-27/36/40W 36TUV
DOUBLE (CFDE),
4 PIN 26W
TRIPLE (CFTE),
4 PIN 26/32/42W
2D28/38W
3.00
HOTSPOT
2.5
TRIPLE (CFTE),
4 PIN 57/70W
CIRCLINE (CFTE),
22W 40W
GPH793T5L
Wiring Diagram
1 Lamp Operation
2 Lamp Operation
BLUE
BLUE
BLACK
WHITE
GROUND
BALLAST
YELLOW
YELLOW
RED
RED
• Specifications are subject to change without notice.
Howard Lighting Products | 580 Eastview Drive | Laurel, MS 39443
(toll free) 800.956.3456 | (direct) 601.422.0033 | (fax) 601.422.1652