DS DALI PS2 standby en
luxCONTROL lighting control system
DALI control units
DALI PS2 standby
DALI power supply for installation in switchgear cabinets
and standby function
Product description
T
•For supplying 240 mA for DALI devices or control modules
without their own power supplies
•For installation in switching cabinets
U
•Automatic monitoring of the connected luminaires
•The built-in relay isolates the connected equipment
from the power supply via an external contactor
if all the luminaires are switched off
•The ballasts are switched on and set to the required
O
status via DALI commands
220 – 240 V
Mains frequency
50 / 60 Hz
Power
5W
Max. output current, DALI
240 mA
Output voltage
16 V ±5 %
Operating temperature
0 ... +50 °C
Storage temperature
0 ... +70 °C
Type of protection
IP20
AS
E
Rated supply voltage
D
Technical data
Ordering data
Type
Article number
Packaging, carton
DALI PS2 Standby
86458560
25 pc(s).
Specific technical data
Type
Max. switching current
250 V
1A
PH
DALI PS2 Standby
Output, relay
Max. switching voltage AC
Data sheet 07/13-CO033-0
Subject to change without notice.
www.tridonic.com
DC switching capability
at 100-250 VDC
at 50-100 VDC
at 0-50 VDC
0.3 A
0.5 A
1.0 A
1
luxCONTROL lighting control system
DALI control units
*
L
DALI PS2
Standby
DA
Standards
EN 55015
EN 61547
EN 61000-3-2
EN 61000-3-3
EN 61347-2-11
EN 62386-101
L
PCA EXCEL
one4all
PCA EXCEL
one4all
R1
R2
DA
DALI
GC
Glow-wire test
according to
EN 60598-1 passed.
DALI
SC
* the inrush currents of the ECGs must be taken into account when dimensioning the contactor
DALI
Limitation
The DALI PS2 Standby is not compatible with the following DALI devices because
of a flashing of the lamp on return to supply voltage:
TALEXXconverter 0025 K210 24 V
TALEXXconverter 0025 K211 24 V
TALEXXconverter 0018 K350 DALI RGB
TE-0105 one4all
DALI 3 RM-C
DALI DSI II
O
Functional description
The DALI PS2 Standby monitors the connected units in the DALI circuit. As soon
as it detects that all the DALI units have been switched off it changes to standby
mode after a user-definable delay and switches a built-in relay contact. With the
aid of this relay contact the connected units can be disconnected from the power
supply via a contactor. Only the DALI control modules are then still in the DALI
circuit.
As soon as a DALI control module sends a “Light ON” command the DALI PS2
Standby reverts to normal operating mode, connects the units back to the power
supply and puts them in the required status.
U
circuit diagram
T
N
R1 R2 N
N
L
L’
N
L
The DALI PS2 Standby is not compatible with DALI devices which do not support
the DALI command “Query Lamp Power ON”, e. g. the PCI FOX B011.
D
The parameters of the DALI PS2 Standby, such as delay, monitoring interval
etc. can be set using the masterCONFIGURATOR (from V1.22) configuration
software. The software tools can be downloaded free of charge from the Tridonic
homepage.
AS
E
LEDs status
LED DA: Lights up if the power supply is ready for operation. The LED goes out briefly when there is communication on the DALI bus (factory default)
LED Stdby: Lights up when standby mode is active (factory default)
The function of the two status LEDs can be inverted with the
masterCONFIGURATOR or configTOOL configuration software.
The DALI PS2 Standby is conditionally compatible with the following DALI control
devices:
x-touchBOX / x-touchPANEL (on return to supply voltage commands can get
lost)
DALI MSensor with firmware version before V1.4
DALI Somfy animeo Interface with firmware version before V1.9
The DALI PS2 Standby is not suitable in conjunction with units that have to be
supplied with power at all times, such as emergency lighting systems
To initialise / adress the DALI service the DALI PS2 Standby must be "active".
PH
DALI units “ON“
DALI units “OFF“
1
2
3
4
5
t
standby mode “ON“
standby mode “OFF“
Power-State-Request
Waiting time
t
Switch OFF
delay
Data sheet 07/13-CO033-0
Subject to change without notice.
Status request for the units from the DALI PS2 Standby
Power Supply detects all units off
Switch-off delay expires (parameter: Switch off delay)
Power Supply switches to standby mode (relay is opened)
“ON” command from a control module; Power Supply leaves standby mode
(relay closes)
www.tridonic.com
2
luxCONTROL lighting control system
DALI control units
Description of parameters
Parameter
Range
Description
Factory default
“Power-State-Request-
1 min – 23 h
in this interval the DALI devices are polled about their state of operation
5 min
Waiting-Time”
Switch-Off delay
EVG-Startup delay
1 min – 2 d
0.01 – 1 s
delay between detection that all the DALI units have been switched off and changeover to standby mode
in the startup process (leaving the standby mode) all the commands are buffered during the “ECG Startup Delay”
1 h
0.51 s
(maximum of 10 commands). At the end of this time the commands are sent by the Power Supply to the ECGs.
LED DA inverted
0, 1
This ensures that none of the commands is lost during the startup process
0... the standby function is activated
1... the standby function is deactivated
0... the relay output is open if all the units have been switched off
0, 1
1... the relay output is closed, if all the units have been switched off
0... lights if the Power Supply is ready for operation. The LED goes out briefly when there is communication
0, 1
buffering size
0, 1
1 – 10
1... lights only if there is communication on the DALI bus
0... lights when standby mode is active
1... lights when standby mode is not active
number of commands which will be max. buffered
wire preparation:
0.25 – 2.5 mm²
AS
E
9 mm
Relay
Insulation to IEC 60664-1
Installation
•DALI signals are not SELV. Therefore the same procedures should be applied
as working with mains voltage
•The relay contacts R1 and R2 are not SELV
•Loads must not be connected directly to the relay (R1, R2). The load must
always be switched via an external contactor.
•When selecting the correct contactor please check the inrush currents of the
switched loads. Electronic ballasts may have very high inrush currents. Check
with the contactor manufacturer.
•Individual DALI circuits must not exceed 240 mA
•The maximum cable length of the DALI signal wires must not exceed 300 m or
drop more than 2 V on the signal line voltage
tc control point
tc: max. 80 °C
12 mm
tc
15 mm
Data sheet 07/13-CO033-0
Subject to change without notice.
10
basic
functional
250 V
3
230 / 400 V
III
PH
Type of insulation
coil-contact circuit
open-contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
0
D
Wiring type and cross section
The wiring can be solid wire, stranded wire or stranded wire with end sleeve with a cross-section of
0.25 mm² to 2.5 mm².
1
O
LED Stdby inverted
0
U
on the DALI bus
0
T
standby mode
deactivated
relay state inverted
www.tridonic.com
tc
3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement