Technical Data Manual
Model Nos. and pricing: see Price List
Vitocell 300-B
EVB Series
Dual-coil, indirect-fired domestic hot water storage tank
79 USG and 119 USG (300 L and 450 L) capacity
Product may not be exactly as shown
Vertical indirect-fired domestic hot water storage tank of high-grade stainless steel with two coils.
One heat exchanger coil facilitates heat transfer from the solar collectors to domestic hot water, a second heat exchanger coil allows reheating of the water content by the hot water heating boiler.
CAUTION
This tank version is not suitable for steam heating applications.
5672 343 - 02 10/2015
2
Product Information
Benefits
Domestic hot water storage tank of high-grade stainless steel highly effective all-around thermal insulation.
Fully hygienic, efficient and economical domestic hot water production by solar collectors and a hot water heating boiler. Heat from the solar collectors is transferred to the domestic hot water via the lower tank coil.
Benefits at a glance:
Corrosion-resistant tank of high-grade SA 240-316
Ti stainless steel offers a long service life.
Fully hygienic due to high quality homogeneous stainless steel surfaces.
The high-alloy material is immune to cracking or peeling. The tank stays hygienic and requires only
Does not require a consumable anode for corrosion
protection.
The entire water content is heated by a 1a in. (34 mm)
diameter stainless steel heat exchanger surface which extends to the bottom of the tank.
Large heat exchanger surfaces allow fast and even heating of the entire water content, guaranteeing a high level of domestic hot water comfort.
Standby losses minimized by highly effective HCFC-
free
79 USG (300 L) version comes equipped with hard foam.
119 USG (450 L) version is supplied with removable soft PET insulation for easier handling.
Two thermometers to show the DHW temperature at the top of the tank, and at the midpoint of the
tank.
Tank design is accepted in the State of
Massachusetts as being ASME equivalent.
Certified to CSA Low Lead Content Certification
Program; including US Safe Drinking Water Act, NSF/ANSI
372 as well as other applicable US State
requirements.
Vitocell 300-B, EVB Series Technical Data
Vitocell 300-B, EVB Series Technical Data
Cross Section
Product Information
3
Technical Data
Technical Data
Vitocell 300-B, EVB Series Technical Data
For DHW production in conjunction with solar systems, heating boilers and heating systems, without low limit for dual coil operation.
Suitable for heating systems with:
max. working pressure on heat exchanger side up to 220 psig at 392°F (200°C)
max. working pressure on DHW water side of up to 150 psig at 210°F (99°C)
max. testing pressure on DHW side of 300 psig
Storage capacity
Coil
Recovery rates*3
with a DHW temperature increase from 50 to 113ºF
(10 to 45ºC) and a supply water temperature of......
Recovery rates*3
with a DHW temperature increase from 50 to 140ºF
(10 to 60ºC) and a supply water temperature of......
Supply flow rate
for the recovery rates stated
Insulation
Standby losses*4
Dimensions*5
Tank length without insulation
Overall length with insulation
Tank width without insulation
Overall width with insulation
Tank height without insulation
Overall height with insulation*6
Tilt height without insulation
Tilt height with insulation
Weight
Tank with insulation
Heat exchanger coil
Heat exchanger surface area
Connections
Coils
Domestic cold/hot water
Recirculation
USG (L)
GPM m 3/h
MBH/24 h in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm)
∅ in. (male NPT thread)
∅ in. (male NPT thread)
∅ in. (male NPT thread)
79 (300)
upper*1 lower*2
273 (80)
519 (1965)
218 (64)
415 (1572)
318 (93)
604 (2285)
246 (72)
467 (1769)
154 (45)
292 (1106)
96 (28)
182 (688)
51 (15)
97 (368)
253 (74)
336 (1273)
178 (52)
337 (1277)
102 (30)
195 (737)
51 (15)
97 (368)
280 (82)
372 (1410)
184 (54)
245 (929)
120 (35)
159 (602)
22.0
5.0
202 (59)
268 (1014)
140 (41)
186 (705)
22.0
5.0
PUR Foam
7.2
--
25 (633)
--
27c (704)
--
70 (1779)
--
71f (1821)
119 (450)
upper*1 lower*2
273 (80)
519 (1965)
218 (64)
415 (1572)
154 (45)
292 (1106)
96 (28)
182 (688)
51 (15)
97 (368)
253 (74)
336 (1273)
184 (54)
245 (929)
120 (35)
159 (602)
22.0
5.0
328 (96)
623 (2358)
249 (73)
474 (1793)
191 (56)
364 (1376)
126 (37)
240 (909)
61 (18)
117 (442)
276 (81)
368 (1393)
212 (62)
282 (1066)
147 (43)
195 (739)
22.0
5.0
Soft PET insulation
9.2
28 (715)
36b (925)
36 (914)
38e (975)
65b (1667)
68b (1738)
66b (1690)
-lbs (kg) 251 (114)
USG (L) 2.9 (11) 2.9 (11)
275 (125)
2.9 (11) 3.9 (15) ft.
2 (m 2 ) 16.1 (1.5) 16.1 (1.5) 15.6 (1.45) 20.5 (1.9)
1
1
1
1a
1a
1a
*1 The upper coil is designated for connection to a hot water heating boiler or a heat pump.
*2 The lower coil is designated for connection to solar collector panels or heat pumps.
*3 When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump.
The stated recovery rate is only achieved when the rated output of the boiler is equal to or greater than that stated under “Recovery rate”.
*4 Measured values are based on a room temperature of 68°F (20ºC) and a domestic hot water temperature of
149°F (65ºC) and can vary by ± 5%.
*5 For other dimensions, see illustrations and tables on pages 5 and 6.
*6 Adjustable feet can be adjusted up to 2 in. (50 mm).
4
For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product.
Vitocell 300-B, EVB Series Technical Data
79 USG (300 L) Tank
Dimensions
79 USG (300 L) Tank
DHW tank temperature sensor in solar heating applications 79 USG (300 L).
Technical Data
Dimensions
Storage capacity
a k m d e b c f g h n
USG (L)
in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm)
79 (300)
3b (87)
12 (301)
29b (751)
37b (951)
33g (1101)
54 (1369)
64b (1640)
14 (357)
4 (100)
29b (751)
54 (1369)
Legend
IO Inspection and clean-out opening
D Drain
BWR Boiler water return (upper coil)
SCR Solar collector return (lower coil) or boiler return
BWS Boiler water supply (upper coil)
SCS Solar collector supply (lower coil) or boiler supply
DCW Domestic cold water
SW1 Sensor well opening for DHW tank temperature sensor or boiler controller aquastat (located at the same height as BWS [79 USG (300 L) only],
rotated
SW2 Sensor well for lower thermometer at SCS level
DHW Domestic hot water
RT Recirculation tapping
TPV Temperature and pressure relief valve
*
1
For solar heating systems Viessmann recommends placement of the DHW tank temperature sensor in
the solar collector return (SCR). This requires a
brass elbow with sensor well (see price list, Vitosol
accessory).
The DHW tank temperature sensor of the boiler control is placed in SW1.
Legend
A DHW tank temperature sensor for solar application
(included with solar control unit)
B
Brass elbow with sensor well
C Solar collector return connection.
5
Technical Data
119 USG (450 L) Tank
Dimensions
119 USG (450 L) Tank
DHW tank temperature sensor in solar heating applications 119 USG (450 L).
Vitocell 300-B, EVB Series Technical Data
Dimensions
Storage capacity
a d e b c f g h k m n
USG (L)
in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm)
119 (450)
3b (102.5)
17c (453)
31b (802)
35c (912)
39c (1012)
47c (1216)
63 (1601)
20 (508)
4 (100)
32 (802)
46 (1170)
Legend
IO Inspection and clean-out opening
D Drain
BWR Boiler water return (upper coil)
SCR Solar collector return (lower coil) or boiler return
BWS Boiler water supply (upper coil)
SCS Solar collector supply (lower coil) or boiler supply
DCW Domestic cold water
SW1 Sensor well opening for DHW tank temperature sensor or boiler controller aquastat.
SW2 Sensor well for lower thermometer at SCS level
DHW Domestic hot water
RT Recirculation tapping
TPV Temperature and pressure relief valve
*
1
For solar heating systems Viessmann recommends placement of the DHW tank temperature sensor in
the solar collector return (SCR). This requires a
brass elbow with sensor well (see price list, Vitosol
accessory).
The DHW tank temperature sensor of the boiler control is placed in SW1.
6
Legend
A DHW tank temperature sensor for solar application
(included with solar control unit)
B
Brass elbow with sensor well
C
Solar collector return connection.
Vitocell 300-B, EVB Series Technical Data
Water Flow
Pressure drop on heating water side of a single coil Domestic hot water pressure drop
Technical Data
Legend
A
Lower indirect coil, 119 USG (450 L) capacity
B Lower indirect coil, 79 USG (300 L) capacity
C Upper indirect coil, 79 USG (300 L) and
119 USG (450 L) capacity
Domestic hot water draw rate
Storage tank contents heated to 140ºF (60ºC), boiler not reheating
Storage capacity
Domestic hot water draw
Water with t = 140ºF (60ºC) (constant)
Percentage tank volume
USG (L)
USG (L)
%
79 (300)
34 (128)
42
119 (450)
62 (233)
52
7
Product Installation
Standard Equipment
79 USG (300 L) capacity DHW Tank
DHW tank made from high-alloy stainless steel with fitted PUR hard foam thermal insulation.
– 2 thermometers °F / °C
– adjustable levelling bolts
The following is packed separately and attached to the crate:
– installation fittings package: with the necessary brass adaptors, other necessary hardware.
– sensor well with insulation
– temperature and pressure relief valve.
Must be ordered separately:
– 1 brass elbow with sensor well for solar collector return, (see price list, Vitosol accessory).
Vitocell 300-B, EVB Series Technical Data
119 USG (450 L) capacity DHW Tank
DHW tank made from high alloy stainless steel and separately packed soft PET thermal insulation.
– 2 thermometers °F / °C
– adjustable levelling bolts
The following is packed separately and attached to the crate:
– installation fittings package: with the necessary brass adaptors, other necessary hardware.
– sensor well with insulation
– temperature and pressure relief valve.
Must be ordered separately:
– 1 brass elbow with sensor well for solar collector return, (see price list, Vitosol accessory).
Domestic hot water connection
8
Legend
A
Domestic hot water supply
B
DHW recirculation line
C
DHW recirculation pump
D Spring-loaded flow check valve
E Discharge pipe
F
Pressure and temperature relief valve
G
Shut-off valve
H
Drain
K Domestic cold water supply lines
L Backflow preventer
M
Domestic cold water inlet
M
Precharged expansion tank
(required where backflow preventer is installed; check local plumbing codes and requirements)
O Thermostatic mixing valve/anti-scald valve for solar applications (field supplied)
WARNING
Due to the potentially high DHW temperatures generated by the solar heating system, the domestic hot water temperature must be limited to a maximum of 140°F
(60°C) by installing a mixing device, e.g. a thermostatic mixing valve. The mixing device does not completely eliminate the risk of scalding at the tap. The installation of a mixing tap is required.
Vitocell 300-B, EVB Series Technical Data
System Design Guidelines
Installation Example
Product Installation
Legend
A Solar collector
B
Vitocell 300-B
C
Filling valve
D
Solar-Divicon (pumping station)
E Recirculation pump
F Anti-scald tempering valve
HC Heating circuit
B Oil/Gas-fired boiler
DCW Domestic cold water
DHW Domestic hot water
T&P Temperature and pressure relief valve
9
10
Product Installation
System Design Guidelines
(continued)
Vitocell 300-B, EVB Series Technical Data
Sensor well
The supplied stainless steel sensor wells are to be used for control sensors to ensure maximum operational safety. The top sensor well is used for the DHW sensor connected to the boiler control.
Should the supplied sensors not fit into the sensor wells, other stainless steel sensor wells must be used.
For solar heating systems, Viessmann recommends placement of the DHW tank temperature sensor in the solar collector return. This requires a brass elbow with sensor well included in the accessory pack (see page 8).
Storage capacity
a b
WARNING
USG (L) 79 (300)
in. (mm) in. (mm)
8.7 (220)
7.9 (200)
119 (450)
13 (330)
12a (310)
To ensure optimum, safe operation, the supplied stainless steel well must be installed. The well diameter is large enough to accommodate a wide variety of sensing bulbs.
Always use spring clip to ensure proper contact of capillary bulb against the stainless steel well for proper sensing/heat transfer!
Heating water supply temperature over 230ºF (110ºC)
These operating conditions require the installation of an additional safety high limit into the DHW storage tank, preventing the temperature from rising above 203ºF
(95ºC). A domestic hot water tempering valve must be used.
Temperature and pressure relief valve
A 150 psi temperature and pressure relief valve (T&P relief valve) is supplied with the tank. The heating contractor must install the valve on each tank in a method meeting code requirements. If local codes require a different relief valve, substitute the manufacturer’s supplied valve. The tank is approved for 100 psig where a Canadian Registration Number (CRN) is required.
Maximum operating pressure is 150 psig.
The T&P relief valve supplied with the tank is tested under ANSI Z21.22 Code for Relief Valves and Automatic
Gas Shut-off Devices for Hot Water Supply Systems.
Backflow preventers
Where backflow preventers are required, a domestic water expansion tank installation is recommended in the cold water inlet piping before the cold water enters the Vitocell. For the backflow device, observe local plumbing codes and regulations.
T&P Valve
ASME pressure steam rating
CSA temperature steam rating
Relief temperature
Inlet thread
Outlet thread
100 psig (where
CRN is required)
150 psig
see ratings marked on T&P valve
205 MBH
210°F (99°C) c c
” male
” female
205 MBH
210°F (99°C) c c
” male
” female
Recirculation tapping
The recirculation tapping is on a separate tapping (see page 5). Cap this opening if the tank is not installed with recirculation.
Warranty consideration
Viessmann DHW tanks require that the water to be heated must be of drinking (potable) water quality and that any water treatment equipment in use must function correctly.
Viessmann accepts no responsibility for damage howsoever caused and reserves the right to withdraw the product warranty if the product has been improperly installed or misapplied by the installer, contractor or final user. In order to qualify for product warranty, strict adherence to the installation and service manuals must be assured.
In the event that Viessmann non-approved components are utilized, Viessmann reserves the right to withdraw all expressed or implied warranties without written notice.
The water to be heated with the Vitocell must be drinking
(potable) water quality. If the tank is used to heat other media, the warranty will be null and void.
Damage resulting from excessive pressure or temperature is clearly not the responsibility of Viessmann.
The amount of chloride and sulfate acceptable to the tank is limited. In areas where high concentrations of chloride and sulfate are present in drinking water, please consult
Viessmann for directions.
For full warranty details, please read the product warranty sheet.
Vitocell 300-B, EVB Series Technical Data
11
Vitocell 300-B, EVB Series Technical Data
Printed on environmentally friendly (recycled and recyclable) paper.