Benefits of Mixed Flow Fans
Twin City Fan Model QSL Mixed Flow Fan combines
the benefits of axial flow and centrifugal flow fans. The
QSL has the advantage of the compact design and
straight-through airflow as well as the preferred acoustic
characteristics and high pressure capability. QSL fans
offer superior air and sound performance and the AMCA
certified rating seal for air and sound.
Energy Savings
Mixed flow fans offer the economy of operation with a
higher and broader efficiency range. The lower operating speed for a given performance provides longer and
more reliable operation.
Ultra Quiet
The AMCA Certified Ratings for Air and Sound applies
to both inlet and outlet sound power levels. The table
below displays sound and static efficiency differences
between performance points for a comparable tubular
centrifugal fan and a vane axial fan.
QSL Mixed Flow
Fan, Outlet View
Static Efficiency (%)
Sound LwA (dB)
Performance
Size
QSL
TSL
TCVA
QSL
TSL
TCVA
2.35 m3/sec @ 250 Pa
QSL 245
70
55
61
72
77
79
82
4.72 m /sec @ 250 Pa
QSL 330
70
63
63
72
81
11.80 m3/sec @ 750 Pa
QSL 402
72
68
65
86
92
98
23.60 m3/sec @ 1500 Pa
QSL 490
71
69
64
95
102
112
3
Mixed Flow Models
QSL – Available in both direct drive and belt driven.
The QSL mounts both vertically and horizontally,
allowing for numerous applications with multiple
mounting arrangements. Sizes range from 150 - 730
and performance ranges from 0.6 to 75 m3/sec. Model
QSL is UL/CUL 705 listed.
QSLR – Model QSLR is similar to the QSL but is
specifically designed for exhausting grease-laden air
from kitchens, restaurants and cooking and dishwasher
hoods. Model QSLR is UL/CUL 762 listed for the
exhaust of grease-laden air.
QSLSH – Model QSLSH is specifically designed for
Application
Mixed flow fans are becoming a popular choice on many
air supply, return, general and grease-laden exhaust and
laboratory exhaust applications in the HVAC industry
for both constant or variable air volume systems. The
efficiency and sound characteristics of the mixed flow
fans are often desired in buildings such as hospitals,
libraries, theaters, and general offices. The Twin City
Fan heavy-duty construction of QSL fans also make
them suitable for many industrial applications handling
ambient air. Applications involving fumes, spray booth
exhaust, particulate, heavy moisture content, or high
temperature should be discussed with the factory for
possible product modifications.
smoke control applications. UL/CUL listed for smoke
control systems for 250°C for 4 hours or 525°C for 15
minutes.
Twin City Fan & Blower certifies that the Models
QSL, QSLR and QSLSH Mixed Flow Fans
shown herein are licensed to bear the AMCA
Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA
Certified Ratings Program. See Catalogue 1061
for sound ratings.
2
TWIN CITY FAN - CATALOGUE M1060
Model QSL is available with the UL/CUL 705 listing for electrical, File No. E158680.
Model QSLR is UL/CUL 762 listed for the
exhaust of grease-laden air as standard, File No.
MH-25478.
Model QSLSH is UL/CUL listed for Smoke Control
Systems as standard, File No. MH-29313, 250°C
for 4 hours and 525°C for 15 minutes.
CONSTRUCTION FEATURES
Housings
All fans are constructed of heavy-gauge steel and
continuously welded for strength and rigidity. All QSL
fans are provided with punched inlet and outlet flanges
as standard.
Impeller
The QSL impeller is designed with true aerofoil (double
surface - hollow) die-formed, continuously-welded blades
for a stable air performance throughout the operating
range. The impeller is statically and dynamically
balanced prior to assembly and rechecked for balance
after assembly by Twin City Fan & Blower.
QSL Impeller
Belt Guard
Totally enclosed, sealed belt guard is standard on
Model QSL. Totally enclosed, non-sealed belt guard is
standard on Models QSLR and QSLSH.
Inner Cylinder
The inner tube is rigidly constructed to support the shaft
and bearings. The removable discharge cone provides
full access to the shaft, bearings, and fan sheave. It is
strongly recommended that an access door be provided
in the ductwork adjacent to the discharge end of the
fan for such service.
Bearings
Standard bearings are selected to exceed the L-10 life
of 40,000 hours at the maximum operating speed.
Drives
V-belt drives or direct drive fans with motors and drives
mounted by Twin City Fan Companies are test run as a
complete assembly and rechecked for balance.
Straightening Vanes
Straightening vanes convert tangential velocity pressure
into useful static pressure, reducing turbulence and
increasing efficiency. Extensive testing of various
shapes and locations has resulted in the most efficient
aerodynamic design of the straightening vanes.
Extended Lube Lines
Allow for ease of lubrication on all sizes.
Motor Mounting Platform
A heavy-duty motor mounting platform pivots to offer
easy and positive adjustment of belt tension. The motor
mounting platform is offered in eight standard locations
to allow for motor accessibility and space requirements.
Shaft
Shaft diameter sized so that maximum operating speed
does not exceed 70% of first critical speed.
EASY ACCESS DESIGNS
Clamshell Design
Two clamshell style doors swing open wide to provide
complete access to the interior of the fan for maintenance
or cleaning without removal of ductwork. Heavy duty
hinges, positive locking latches, and a full gasket
provides a complete seal when doors are closed. An
access door provides access to the bearings. Available
on all fan sizes, typically vertical mount.
Swing-out Design
Provides full access to the impeller and inner casing.
The entire impeller/shaft/bearing assembly is mounted
on a large swing-out door. Ideal for systems requiring
frequent cleaning without removal of ductwork. Swingout construction is available for vertical mounting only.
Available on sizes 182 and larger.
WWW.TCF.COM
3
MOUNTING CONFIGURATIONS
Horizontal Construction
Vertical Construction
Horizontal construction is available in sizes 150 to 730.
Vertical construction is available in sizes 150 to 542.
Consult factory for larger sizes.
Horizontal Base Mounted (HBM) — Support legs are
provided at each end of the fan for floor mounting.
Floor or Ceiling Mounted (VUI/VUO/VDI/VDO) — Four
vertical brackets are welded to either end of the fan
housing. Bracket location is determined by airflow
direction and support details (see drawing below).
Horizontal Ceiling Hung (HCH) — For duct mounted
fans, four suspension clips are welded to the fan casing
to allow ceiling suspension using rod hangers.
Roof Mounted (VRM) — A curb cap provides weathertight seal for roof curb mounted fans. A discharge cap
and weather cover are also available for the up-blast
style roof ventilator.
Horizontal (HOR) — For mounting configurations where
support legs and suspension clips are not required.
Vertical (VUN/VDN) — For mounting configurations
where support brackets are not required.
Discharge Arrangements
A
H
HCH
Horizontal
Ceiling Hung
A
B
G
C
HBM
Horizontal Base
Mounted
H
G
D
F
B
C
HOR
Horizontal
No Mounting
Brackets
E
NOTE: Horizontal motor positions shown from oulet end.
↑
AIRFLOW
↑
VRM
Vertical Roof
Mounted
↑
AIRFLOW
AIRFLOW
AIRFLOW
↓
AIRFLOW
VUI
Vertical Discharge
Up, Floor Mount
Support Brackets
On Inlet
VUO
Vertical Discharge
Up,Ceiling Hung
Support Brackets
On Outlet
VDI
Vertical Discharge
Down, Ceiling Hung
Support Brackets
On Inlet
VDO
Vertical Discharge
Down, Floor Mount
Support Brackets
On Outlet
↓
Available Discharges by Model
↑
AIRFLOW
AIRFLOW
↓
VUN
Vertical Up
No Brackets
4
VDN
Vertical Down
No Brackets
TWIN CITY FAN - CATALOGUE M1060
QSL
QSLSH
QSLR
HBM
HBM
HBM
HCH
HCH
HCH
HOR
HOR
HOR
VDI
N/A
N/A
VDN
N/A
N/A
VDO
N/A
N/A
VUI
VUI
VUI
VUN
VUN
VUN
VUO
VUO
VUO
VRM
VRM
VRM
OPTIONS/ACCESSORIES
Belt Tube
A belt tube encloses the belts and drive components,
protecting them from the airstream.
Support Legs — Horizontal Flow
For horizontal flow with floor mounting, support legs
are welded to the fan flange with bolt holes aligned for
connection of ductwork.
Support Legs — Vertical Flow
For vertical flow with either floor or ceiling mounting,
support legs are welded to the fan housing for four-point
support.
Suspension Clips
Support Legs, Horizontal
Support Legs, Vertical
Suspension Clips,
Horizontal
Discharge Cap
Curb Cap
Shaft Seal
Inlet/Outlet Screens
Companion Flange
For horizontal flow with ceiling mounting, four clips of
formed angle are welded to the fan housing for suspension
via tie rods to the ceiling support structure.
Inlet and Outlet Screens
Safety screening can be provided for installation in the fan
inlet or fan outlet.
Discharge Cap
Discharge caps are designed for vertical, rooftop discharge
with butterfly type dampers to seal out the weather when
the fan is shut off.
Curb Cap
Attached to the fan’s flange for curb mounting.
Shaft Seal
To limit the air entering the inner cylinder and avoid
contact of airstream contaminants with the bearings and
V-belt drive. Consists of a Teflon wear pad/plate and a
rubber check-seal at the impeller end of the inner cylinder.
Please note that a shaft seal does not make the inner
cylinder gas tight.
Weather Cover
For outdoor installations, the weather cover completely
encloses the motor and V-belt drive from the elements.
Provided with slots for ventilation. Weather covers are
available for either horizontal or vertical flow fans.
Companion Flanges
Flanges are rolled angle rings, drilled to match the fan’s
inlet or outlet flange.
Spark-Resistant Construction
Various grades of spark resistance are as dictated by
AMCA: Types A, B, and C (for ATEX, please enquire).
Spark resistant construction requires the addition of a
sealed belt tube.
Vibration Isolation
Spring or rubber-in-shear isolators as an option. Spring
isolators can be provided for floor mount or ceiling hung
orientation.
Seismic Certification
Models QSL, QSLR and QSLSH have been seismically
tested and certified with the California Office of Statewide
Health, Planning and Development (OSHPD) per OSP0271-10. Seismic certification is limited to certain product
options and configurations.
WWW.TCF.COM
5
QSLR/QSLSH FANS
QSLR Restaurant Fans
QSLSH Smoke & Heat Fans
Model QSLR is CULUS 762 listed for exhaust of greaseladen air. QSLR is licensed to bear the AMCA certified
ratings seal for sound and air performance.
Model QSLSH is CULUS 705 listed and CULUS listed for
smoke control systems for 250°C for 4 hours or 525°C
for 15 minutes. Vertical roof mounted configuration,
with discharge cap, meets UL 793 Snow Load Test
requirements for butterfly dampers. QSLSH is licensed
to bear the AMCA certified ratings seal for sound and
air performance.
Twin City Fan Companies offers a specially modified
version of the QSL fan designated as "QSLR" (Mixed
Flow Restaurant Exhaust) for exhausting grease-laden
air from kitchens, restaurants, cooking and dishwasher
hoods. QSLR is available in sizes 150 to 730.
The QSLR fan is available in all configurations with the
exception of vertical down (VDN, VDO and VDI).
Standard Product Features
• Belt guard, totally enclosed, ventilated (weather cover
for VRM)
• Belt tube, sealed
• Two cleanout doors located 180° apart (90° from
motor)
• 50 mm drain located 180° from motor (lowest point
for horizontal) vertical at the funnel
• Cooling fins on impeller
• Housing sealed with Hi-Temp caulk
Twin City Fan Companies offers a specially modified
version of the QSL fan designated as "QSLSH" (Mixed
Flow Smoke and Heat Exhaust) for smoke control
applications where temperatures can reach 525°C.
QSLSH is available in sizes 150 to 730.
The QSLSH fan is available in all configurations with
the exception of vertical down (VDN, VDO and VDI).
Standard Product Features
•
•
•
•
•
•
Belt guard, ventilated (weather cover for VRM)
Belt tube, sealed
Two-groove drive minimum w/2.0 SF
Cooling fins on impeller
Stack cap with fusible link (for VRM)
Continuously welded housing
DISCHARGE
CAP (OPTIONAL)
AIR
FLOW
(2) CLEANOUT DOORS
90 FROM MOTOR
180 FROM EACH OTHER
(STANDARD ON QSLR ONLY)
O
O
2“ GREASE DRAIN
180 FROM MOTOR
(STANDARD ON QSLR ONLY)
WEATHER
COVER
(STANDARD)
O
GREASE BOX
(OPTIONAL ON QSLR ONLY)
6
TWIN CITY FAN - CATALOGUE M1060
CURB CAP
(OPTIONAL)
CURB BASE
(OPTIONAL)
OPTIONS & ARRANGEMENTS
Insulated Enclosure
To further reduce case radiated sound and motor
noise, an optional Insulated Enclosure is available. The
enclosure consists of a box with 50 mm thick, dual
density fiberglass. Consult the factory for dimensions
and sound reduction values.
AIR FLOW
Arrangement 4 (Direct Drive)
Where space constraints require the use of a complete
"in line" fan or the desire is for a simple, dependable
fan with minimum maintenance requirements, the direct
drive Arrangement 4 QSL is available. Constructed
with the fan impeller mounted directly on the motor
shaft, this fan provides premium efficiency with minimal
obstructions in the airstream. The use of a variable
frequency drive (VFD) may be necessary for some
applications.
AIR FLOW
FAN
SIZE
Arrangement 3
Where space is a premium, the QSL arrangement 3 is
available to shorten the overall fan length. The table on
the right shows the overall savings in length versus an
arrangement 9 fan.
182
200
222
245
270
300
330
365
402
445
490
542
ARR. 3
OVERALL
LENGTH
(TA)
679
732
784
862
927
1038
1141
1256
1379
1500
1627
1813
LENGTH
SAVINGS
(mm)
181
213
235
264
313
348
379
430
475
556
633
695
AIR FLOW
WWW.TCF.COM
7
ENGINEERING DATA
Table 1. Maximum RPM, Impeller Weights, and WR2
(moment of inertia in kg-m2)
FAN
SIZE
150
165
182
200
222
245
270
300
330
365
402
445
490
542
600
660
730
MAX.
RPM
2721
2483
2232
2027
1839
1655
1505
1360
1234
1116
1013
915
828
752
680
615
558
CLASS I
WEIGHT
kg
10.9
14.5
17.3
21.8
25.9
31.4
37.3
63.6
75.9
106
147
179
217
269
325
394
484
WR2
(kg-m2)
0.23
0.34
0.51
0.84
1.22
1.90
2.78
5.61
8.30
13.5
24.8
37.2
55.7
81.5
122
183
270
MAX.
RPM
3558
3247
2918
2650
2405
2165
1968
1779
1613
1459
1325
1197
1082
984
890
804
730
CLASS II
WEIGHT
kg
12.7
16.4
20.0
23.6
28.2
34.1
40.9
68.2
81.4
112
147
179
217
269
325
394
484
Table 2. Bare Fan Weights (kg)
WR2
(kg-m2)
0.30
0.43
0.63
0.97
1.43
2.19
3.20
6.11
9.06
14.6
24.8
37.2
55.7
81.5
122
183
270
ARRANGEMENT 9
FAN
SIZE
CLASS I
CLASS II
150
165
182
200
222
245
270
300
330
365
402
445
490
542
600
660
730
76
92
98
117
138
167
197
300
365
463
606
725
906
1138
1366
1764
2145
80
96
103
121
143
171
205
314
373
476
617
740
913
1153
1379
1809
2163
2400
2800
3500
4500
75.62
0.939
0.864
0.772
0.746
0.699
0.647
0.587
71.91
0.893
0.822
0.735
0.71
0.664
0.615
0.558
65.76
0.816
0.752
0.672
0.649
0.608
0.563
0.51
57.73
0.717
0.66
0.59
0.57
0.533
0.494
0.448
Table 3. Temperature and Altitude Density Ratios
AIR
TEMP
°C
-40
-20
10
20
40
65
100
0
300
600
900
101.32
1.258
1.158
1.035
1
0.936
0.867
0.786
97.77
1.214
1.117
0.999
0.965
0.903
0.837
0.758
94.32
1.171
1.078
0.963
0.931
0.871
0.807
0.732
90.97
1.129
1.04
0.929
0.898
0.84
0.778
0.706
ALTITUDE IN METRES ABOVE SEA LEVEL
1200
1500
1750
2000
BAROMETRIC PRESSURE IN kPa
87.71
84.55
81.99
79.49
1.089
1.05
1.018
0.987
1.002
0.966
0.937
0.909
0.896
0.864
0.838
0.812
0.866
0.835
0.809
0.785
0.81
0.781
0.757
0.734
0.751
0.724
0.702
0.68
0.68
0.656
0.636
0.617
Table 5. Minimum m3/sec
Required to Open
Discharge Cap
Table 4. Bearing Specifications
FAN
SIZE
150
165
182
200
222
245
270
300
330
365
402
445
490
542
600
660
730
CLASS I
SHAFT
DIA. mm.)
25
25
25
30
30
38
38
38
42
50
50
50
55
60
70
75
75
CLASS II
HORIZ.
VERT.
SDB
SDB
SDB
SDB
SDB
SDB
SDB
HDB
HDB
HDB
HDB
HDB
HDB
HDB
HDB
HDB
HDB
SDB
SDB
SDB
SDB
SDB
SDB
SDB
HDB
HDB
HDB
RB
RB
RB
RB
—
—
—
SHAFT
DIA. (mm.)
30
38
38
38
38
42
42
50
55
55
55
65
65
70
75
90
100
HORIZ.
VERT.
SDB
SDB
HDB
HDB
HDB
HDB
HDB
HDB
HDB
RB
RB
RB
RB
RB
RB
RB
RB
SDB
SDB
HDB
HDB
HDB
HDB
RB
RB
RB
RB
RB
RB
RB
RB
—
—
—
NOTES:
1. BEARINGS CODES:
SDB — Standard-Duty Ball such as Dodge SCAH or SKF SY Series
HDB — Heavy-Duty Ball such as Dodge SCMAH or SKF SYM Series
RB — Roller Bearing such as Dodge S2000 or SKF SYR Series
2. Standard bearings are selected to exceed L-10 life of 40,000 hours at the maximum
operating speed.
8
TWIN CITY FAN - CATALOGUE M1060
FAN
SIZE
150
165
182
200
222
245
270
300
330
365
402
445
490
542
m3/sec
0.5
0.8
1.2
1.7
1.7
2.2
3.1
3.6
4.1
5.3
7.5
7.5
9.9
12.6
PERFORMANCE CURVES
QSL 150
10
3500 RPM
90
2,000
A
Lw
7
2850 RPM
1,500
85
5
A
Lw
2500 RPM
1,000
A
Lw
2000 RPM
1450 RPM
2.2kW
A
Lw
1.5kW
1.1kW
200
Lw
0.75kW
A
0.7
400
70
1
3kW
A
Lw
1.5
4kW
75
2
PF - Fan Total Pressure (Pa)
600
65
960 RPM
150
0.55kW
60
A
Lw
0.5
100
0.25kW
%
A
Eff
.
Lw
ff.
.E
0.18kW
Pk
0.3
80
0.37kW
55
720 RPM
64
%
60
68
Eff
.
0.2
%
40
56
PF - Fan Total Pressure (in W.G.)
5.5kW
80
800
3
0.2
0.4
0.7
0.5
1
2
0.7
0.6
3
1
5
0.8
1
qv - Flow (m³ / sec)
7
10
20
1.5
30
Pd - Fan Velocity Pressure (Pa)
1.5
2
3
qv - Flow (CFM) (in Thousands)
2
50
4
70
5
100
200
7
Fan Efficiency Grade = FEG 71
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
9
PERFORMANCE CURVES
QSL 165
2,000
2850 RPM
7
1,500
90
2500 RPM
A
Lw
5
85
A
Lw
1,000
2000 RPM
800
3
80
A
Lw
A
Lw
2.2kW
A
Lw
960 RPM
200
1.1kW
A
60
A
Lw
0.55kW
720 RPM
.
0.37kW
.E
ff.
64
%
Eff
100
Pk
80
%
0.25kW
68
0.3
1.5kW
0.75kW
150
0.5
3kW
Lw
0.7
400
70
1
4kW
1450 RPM
75
1.5
PF - Fan Total Pressure (Pa)
2
65
PF - Fan Total Pressure (in W.G.)
600
0.18kW
Eff
.
60
56
%
0.2
40
0.4
0.6
2
3
1
0.8
5
1.5
1
1.5
2
qv - Flow (m³ / sec)
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
2
3
qv - Flow (CFM) (in Thousands)
4
50
5
70
100
7
Fan Efficiency Grade = FEG 71
Notes:
1.
2.
3.
4.
5.
6.
7.
10
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 182
10
2850 RPM
2,000
90
2500 RPM
7
A
Lw
1,500
5
2000 RPM
85
1,000
A
Lw
800
3
1.5kW
200
1.1kW
A
Lw
PF - Fan Total Pressure (Pa)
2.2kW
A
Lw
960 RPM
150
720 RPM
0.75kW
Lw
0.55kW
A
55
100
0.37kW
A
Lw
0.25kW
%
Pk
0.2
0.18kW
ff.
%
Eff
.
60
.E
0.3
80
500 RPM
64
40
56
%
Eff
.
68
PF - Fan Total Pressure (in W.G.)
A
Lw
3kW
60
0.5
4kW
65
0.7
400
70
1
5.5kW
75
1.5
1450 RPM
A
Lw
2
7.5kW
80
600
0.1
20
0.4
0.6
1
2
1
0.8
3
1.5
1
5
1.5
2
4
qv - Flow (m³ / sec)
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
2
3
5
qv - Flow (CFM) (in Thousands)
50
70
7
6
100
200
10
Fan Efficiency Grade = FEG 71
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
11
PERFORMANCE CURVES
QSL 200
10
2500 RPM
2,000
7
90
2000 RPM
5
A
Lw
800
3
1450 RPM
80
4kW
960 RPM
3kW
A
Lw
2.2kW
200
720 RPM
1.5kW
A
PF - Fan Total Pressure (Pa)
A
Lw
400
Lw
0.7
5.5kW
70
1
1.1kW
150
60
0.75kW
A
Lw
0.5
0.55kW
100
500 RPM
80
55
Lw
0.37kW
.E
0.25kW
68
%
Pk
60
ff.
64
%
Eff
.
A
0.3
7.5kW
75
1.5
A
Lw
600
65
PF - Fan Total Pressure (in W.G.)
85
1,000
2
A
Lw
1,500
0.2
0.18kW
56
%
Eff
.
40
0.6
0.8
2
1.5
1
3
1.5
2
4
qv - Flow (m³ / sec)
5
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
2
3
5
qv - Flow (CFM) (in Thousands)
50
7
70
6
100
10
Fan Efficiency Grade = FEG 71
Notes:
1.
2.
3.
4.
5.
6.
7.
12
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 222
2,000
7
2000 RPM
1,500
5
85
A
Lw
1,000
7.5kW
1450 RPM
800
80
3
A
Lw
5.5kW
A
Lw
960 RPM
4kW
3kW
A
Lw
2.2kW
720 RPM
1.5kW
200
Lw
1.1kW
A
0.7
400
70
1
75
1.5
PF - Fan Total Pressure (Pa)
2
65
150
0.75kW
60
A
Lw
0.5
0.55kW
Eff
.
500 RPM
100
%
0.37kW
.
Eff
0.25kW
Pk
.
0.3
80
69
60
74
%
0.18kW
%
Eff
.
0.2
40
66
PF - Fan Total Pressure (in W.G.)
600
0.8
1
2
1.5
1.5
3
2
5
2
4
qv - Flow (m³ / sec)
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
3
5
7
qv - Flow (CFM) (in Thousands)
6
50
70
100
10
Fan Efficiency Grade = FEG 75
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
13
PERFORMANCE CURVES
QSL 245
10
2000 RPM
2,000
7
90
A
Lw
1,500
5
85
1450 RPM
A
Lw
960 RPM
A
Lw
400
4kW
3kW
A
720 RPM
2.2kW
200
1.5kW
A
Lw
0.7
1.1kW
60
150
500 RPM
A
Lw
0.75kW
Eff
.
0.5
5.5kW
Lw
PF - Fan Total Pressure (Pa)
80
7.5kW
70
1
600
75
1.5
11kW
65
PF - Fan Total Pressure (in W.G.)
800
3
2
A
Lw
1,000
%
100
Pk
80
%
0.37kW
75
0.3
.E
ff.
69
0.55kW
0.25kW
1
2
67
%
Eff
.
60
1.5
3
2
2
5
3
7
qv - Flow (m³ / sec)
10
20
4
6
30
50
Pd - Fan Velocity Pressure (Pa)
5
7
qv - Flow (CFM) (in Thousands)
10
70
8
100
15
Fan Efficiency Grade = FEG 75
Notes:
1.
2.
3.
4.
5.
6.
7.
14
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 270
1,500
1450 RPM
5
1,000
85
A
Lw
800
3
7.5kW
80
960 RPM
A
Lw
5.5kW
A
Lw
720 RPM
4kW
3kW
70
A
Lw
1
400
75
1.5
PF - Fan Total Pressure (Pa)
2
2.2kW
200
65
Lw
0.7
A
1.5kW
500 RPM
1.1kW
Eff
.
150
%
0.5
ff.
69
.E
0.75kW
Pk
100
75
%
0.55kW
%
Eff
.
0.3
80
60
66
PF - Fan Total Pressure (in W.G.)
600
1
1.5
2
3
3
2
5
0.37kW
qv - Flow (m³ / sec)
7
10
4
6
20
Pd - Fan Velocity Pressure (Pa)
5
7
qv - Flow (CFM) (in Thousands)
30
10
50
8
70
100
15
Fan Efficiency Grade = FEG 75
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
15
PERFORMANCE CURVES
QSL 300
2,000
7
1450 RPM
90
1,500
A
Lw
5
1,000
85
A
Lw
800
3
960 RPM
80
600
500 RPM
3kW
A
Lw
2.2kW
150
1.5kW
1.1kW
A
Lw
PF - Fan Total Pressure (Pa)
A
Lw
200
100
0.75kW
55
PF - Fan Total Pressure (in W.G.)
A
Lw
4kW
60
0.5
5.5kW
65
0.7
7.5kW
70
1
720 RPM
400
75
1.5
Lw
80
A
0.3
11kW
A
Lw
2
0.55kW
300 RPM
.
60
%
Eff
0.37kW
.E
ff.
69
0.2
Pk
0.25kW
75
%
40
66
%
Eff
.
0.18kW
0.1
20
1
1.5
1
2
3
2
3
4
qv - Flow (m³ / sec)
5
7
10
20
6
8
30
50
Pd - Fan Velocity Pressure (Pa)
5
7
10
qv - Flow (CFM) (in Thousands)
15
10
70
20
15
100
30
Fan Efficiency Grade = FEG 75
Notes:
1.
2.
3.
4.
5.
6.
7.
16
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 330
2,000
1450 RPM
7
1,500
90
A
Lw
5
1,000
A
Lw
3
75
400
A
Lw
7.5kW
5.5kW
70
Lw
200
4kW
A
500 RPM
3kW
A
Lw
PF - Fan Total Pressure (Pa)
11kW
2.2kW
150
60
0.5
1.5kW
A
Lw
1.1kW
100
55
0.75kW
Eff
.
A
Lw
0.55kW
%
0.3
300 RPM
80
69
Pk
.
Eff
.
60
0.2
0.37kW
75
%
40
%
Eff
.
0.25kW
66
PF - Fan Total Pressure (in W.G.)
720 RPM
65
0.7
15kW
A
Lw
2
1
18.5kW
80
600
1.5
85
960 RPM
800
1
1.5
0.7
1
2
2
3
4
6
8
qv - Flow (m³ / sec)
3
5
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
5
7
10
15
qv - Flow (CFM) (in Thousands)
10
50
20
15
70
100
20
200
30
Fan Efficiency Grade = FEG 75
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
17
PERFORMANCE CURVES
QSL 365
10
1450 RPM
2,000
95
7
A
Lw
1,500
37kW
90
5
A
Lw
A
Lw
A
Lw
11kW
500 RPM
7.5kW
Lw
A
5.5kW
200
4kW
A
3kW
150
2.2kW
60
0.5
A
Lw
300 RPM
100
1.1kW
Pk
.E
ff.
72
A
%
80
Lw
Eff
.
1.5kW
55
0.3
80
15kW
400
Lw
0.7
22kW
18.5kW
70
1
720 RPM
75
1.5
PF - Fan Total Pressure (Pa)
600
30kW
65
PF - Fan Total Pressure (in W.G.)
85
800
3
2
A
Lw
960 RPM
1,000
0.75kW
76
%
60
0.2
Eff
.
0.55kW
65
%
40
2
0.37kW
4
2
3
5
5
7
6
8
10
15
qv - Flow (m³ / sec)
7
10
20
30
50
Pd - Fan Velocity Pressure (Pa)
10
15
20
qv - Flow (CFM) (in Thousands)
70
30
100
20
200
300
50
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
18
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 402
1,500
960 RPM
5
1,000
85
800
A
Lw
3
720 RPM
600
80
A
Lw
2
A
Lw
7.5kW
5.5kW
200
4kW
A
PF - Fan Total Pressure (Pa)
A
Lw
11kW
Lw
0.7
500 RPM
70
1
400
75
1.5
65
150
3kW
300 RPM
60
Lw
0.5
Eff
.
A
2.2kW
%
100
.E
ff.
72
Pk
1.5kW
%
0.3
80
76
1.1kW
Eff
.
60
0.75kW
65
%
PF - Fan Total Pressure (in W.G.)
15kW
0.2
0.55kW
40
4
3
7
6
5
7
10
8
qv - Flow (m³ / sec)
10
20
10
15
30
Pd - Fan Velocity Pressure (Pa)
15
20
qv - Flow (CFM) (in Thousands)
50
20
70
100
30
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
19
PERFORMANCE CURVES
QSL 445
2,000
7
960 RPM
1,500
5
90
A
Lw
1,000
720 RPM
A
Lw
3
85
800
600
80
Lw
A
300 RPM
150
4kW
3kW
A
100
2.2kW
Lw
80
A
1.5kW
200 RPM
1.1kW
%
Eff
.
60
72
0.2
ff.
PF - Fan Total Pressure (Pa)
5.5kW
Lw
PF - Fan Total Pressure (in W.G.)
A
Lw
A
Lw
7.5kW
200
55
0.3
11kW
60
0.5
15kW
65
0.7
18.5kW
70
1
22kW
500 RPM
400
75
1.5
A
Lw
2
Pk
.E
0.75kW
%
40
Eff
.
76
0.55kW
65
%
0.37kW
0.1
0.25kW
20
2
4
1
2
5
7
3
6
8
10
15
qv - Flow (m³ / sec)
5
7
10
20
30
50
Pd - Fan Velocity Pressure (Pa)
10
15
20
qv - Flow (CFM) (in Thousands)
20
30
70
100
50
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
20
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 490
2,000
7
960 RPM
95
A
Lw
1,500
5
90
720 RPM
A
Lw
1,000
45kW
85
800
A
Lw
3
600
11kW
A
Lw
200
7.5kW
300 RPM
5.5kW
A
PF - Fan Total Pressure (Pa)
A
Lw
A
Lw
15kW
Lw
150
4kW
60
0.5
Lw
200 RPM
2.2kW
55
Eff
.
A
Lw
1.5kW
%
0.3
80
3kW
A
100
Pk
.E
60
ff.
72
1.1kW
%
0.2
76
0.75kW
Eff
.
40
%
0.55kW
65
PF - Fan Total Pressure (in W.G.)
80
22kW
18.5kW
65
0.7
400
70
1
30kW
75
1.5
37kW
500 RPM
2
4
6
2
7
3
10
8
5
7
10
15
20
qv - Flow (m³ / sec)
10
20
30
Pd - Fan Velocity Pressure (Pa)
15
20
30
qv - Flow (CFM) (in Thousands)
50
70
100
50
70
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
21
PERFORMANCE CURVES
QSL 542
10
960 RPM
2,000
7
95
A
Lw
1,500
720 RPM
5
75kW
90
A
Lw
1,000
800
15kW
300 RPM
A
11kW
200
7.5kW
Lw
PF - Fan Total Pressure (Pa)
A
Lw
A
Lw
22kW
18.5kW
Lw
0.7
30kW
400
70
1
45kW
37kW
75
1.5
A
150
5.5kW
0.5
60
4kW
Lw
A
100 200 RPM
Eff
.
3kW
%
80
2.2kW
Pk
.E
ff.
72
0.3
55kW
80
2
A
Lw
500 RPM
600
65
PF - Fan Total Pressure (in W.G.)
85
3
%
60
76
1.5kW
0.2
Eff
.
1.1kW
65
%
40
4
2
6
8
3
5
10
15
0.75kW
10
7
15
qv - Flow (m³ / sec)
10
20
20
30
Pd - Fan Velocity Pressure (Pa)
20
30
qv - Flow (CFM) (in Thousands)
40
50
50
70
100
70
200
100
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
22
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 600
2,000
7
720 RPM
1,500
5
90
800
500 RPM
85
3
A
Lw
600
A
Lw
200
11kW
Lw
150
A
7.5kW
200 RPM
5.5kW
A
PF - Fan Total Pressure (Pa)
A
Lw
15kW
Lw
100
4kW
80
3kW
Lw
A
150 RPM
2.2kW
%
Eff
.
60
1.5kW
Pk
.E
0.2
ff.
72
1.1kW
%
40
76
Eff
.
0.75kW
65
%
PF - Fan Total Pressure (in W.G.)
A
Lw
75
18.5kW
55
0.3
22kW
300 RPM
60
0.5
30kW
65
0.7
37kW
400
70
1
45kW
80
2
1.5
55kW
A
Lw
1,000
0.1
20
4
6
1
8
2
10
3
15
0.55kW
10
5
15
qv - Flow (m³ / sec)
7
10
20
40
20
Pd - Fan Velocity Pressure (Pa)
20
30
qv - Flow (CFM) (in Thousands)
30
50
50
70
70
100
100
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
23
PERFORMANCE CURVES
QSL 660
2,000
720 RPM
7
95
1,500
A
Lw
5
90kW
90
1,000
A
Lw
500 RPM
800
3
85
A
Lw
600
75
300 RPM
A
Lw
30kW
22kW
18.5kW
A
Lw
0.7
37kW
70
1
200
200 RPM
11kW
A
150
15kW
Lw
PF - Fan Total Pressure (Pa)
A
Lw
1.5
45kW
400
65
PF - Fan Total Pressure (in W.G.)
55kW
80
2
75kW
7.5kW
0.5
60
A
150 RPM
80
.E
ff.
72
%
A
60
3kW
Lw
Eff
.
4kW
55
0.3
5.5kW
Lw
100
%
Pk
2.2kW
76
0.2
1.5kW
Eff
.
40
65
%
1.1kW
6
8
2
10
3
15
20
15
20
40
qv - Flow (m³ / sec)
5
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
30
50
70
qv - Flow (CFM) (in Thousands)
50
60
70
100
100
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
24
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES
QSL 730
10
720 RPM
2,000
7
95
1,500
A
Lw
5
500 RPM
132kW
90
1,000
A
Lw
800
3
A
Lw
55kW
45kW
37kW
Lw
A
30kW
22kW
70
18.5kW
Lw
200
A
0.7
300 RPM
400
75
1
A
Lw
1.5
90kW
75kW
80
2
PF - Fan Total Pressure (Pa)
600
200 RPM
15kW
150
65
11kW
A
Lw
0.5
7.5kW
60
A
Lw
100 150 RPM
Eff
.
5.5kW
80
%
.E
ff.
4kW
Pk
0.3
72
3kW
%
60
76
0.2
Eff
.
2.2kW
%
40
65
PF - Fan Total Pressure (in W.G.)
85
110kW
8
10
2
15
20
1.5kW
15
3
5
30
20
40
qv - Flow (m³ / sec)
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
50
70
qv - Flow (CFM) (in Thousands)
60
50
100
70
80
100
150
Fan Efficiency Grade = FEG 80
Notes:
1.
2.
3.
4.
5.
6.
7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet.
Power rating (kW) does not include transmission losses.
Performance ratings do not include the effects of appurtenances (accessories).
The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301.
Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet.
Ratings do not include the effects of duct end correction.
The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
25
DIMENSIONAL DATA
Horizontal
MOTOR
"FR"
MAX. FRAME
CB
INSIDE
DIA.
CA
FLOW
"TH"
HSG. GAGE
LOC.
A
MC
MAX
FLANGE
ROTATION
CC
O.D.
AIR
B.C.
DUCT
SEALED BELT GUARD
STD EXCEPT FOR
SPARK RESISTANT
CONSTRUCTION
"NH" NUMBER OF
"DH" DIA. HOLES
ON "CB" DIA. B.C.
EQUALLY SPACED
STRADDLING
CENTER LINE
"SD"
DIA. SHAFT
TA
OUTLET END
TYPE "QSL" HORIZONTAL DISCHARGE
A
BB
D
BD
BN
BE
F
38.1
M
BF
M
HCH
HORIZONTAL BASE MOUNTED
D
E
SUSPENSION
CLIPS
FOUR "BM" DIA.
CLIP HOLES
G
HBM
C
G
SUPPORT
LEGS
FOUR "BH"
DIA. MTG. HOLES
B
H
MOTOR LOCATION
VIEWED FROM
OUTLET END
HORIZONTAL CEILING HUNG
SIZE
BB
BD
BE
BF
BH
BM
BN
BT
CA
CB
CC
D
DH
FR
G
M
MC
NH
150
165
182
200
222
245
270
300
330
365
405
445
490
542
600
660
730
25
25
38
38
38
38
38
38
38
51
51
51
51
51
64
64
64
655
727
785
868
945
1049
1164
1309
1445
1584
1753
1954
2159
2406
2635
2924
3244
27
27
27
27
33
33
33
33
33
40
43
43
43
62
62
62
62
652
724
807
890
954
1059
1173
1318
1455
1607
1769
1970
2175
2384
2638
2927
3247
11
11
11
14
14
14
14
14
14
21
21
21
21
21
21
27
27
14
14
14
14
14
21
21
21
21
21
21
21
21
27
27
27
27
597
657
705
765
842
921
1007
1111
1216
1335
1462
1610
1764
1945
2169
2376
2615
165
165
165
184
203
227
248
278
305
337
375
413
457
505
562
616
683
514
567
627
687
764
842
927
1030
1134
1254
1381
1529
1683
1864
2062
2268
2508
562
619
679
740
816
892
978
1096
1200
1321
1461
1607
1762
1956
2153
2359
2651
594
654
711
770
848
924
1010
1140
1245
1365
1518
1664
1819
2026
2223
2429
2721
356
381
406
457
508
533
584
635
686
737
838
914
991
1092
1194
1321
1448
14
18
18
21
21
21
21
21
21
21
21
21
21
21
21
21
21
132M
132M
160L
160L
160L
180L
180L
200L
200L
225M
225M
250M
250M
280M
280M
280M
280M
594
654
711
770
848
924
1010
1140
1245
1365
1518
1664
1819
2026
2223
2429
2721
259
286
318
347
386
424
467
532
584
645
721
794
871
975
1073
1178
1322
654
706
875
919
956
960
1071
1146
1183
1308
1518
1580
1719
1818
1993
2102
2229
8
8
12
12
12
12
12
16
16
16
16
16
24
24
24
24
24
SD
CL I CL II
25
30
25
35
25
35
30
35
30
35
35
42
35
42
35
50
42
55
50
55
50
55
50
65
55
65
65
70
70
75
75
90
75
100
TA
TH
706
778
861
944
1021
1125
1240
1385
1521
1686
1854
2055
2260
2507
2762
3051
3372
10
10
12
12
12
12
12
10
10
10
10
10
10
10
10
10
10
QSL-AC1000023E
QSLR-AC1001672A
QSLSH-AC1001666B
DIMENSIONS ARE SUBJECT TO CHANGE. CERTIFIED DRAWINGS AVAILABLE ON REQUEST.
26
TWIN CITY FAN - CATALOGUE M1060
DIMENSIONAL DATA
Vertical
O.D.
CC
CB
DIA.
INSIDE
CA
FLANGE
B.C.
“BT”
BELT TUBE WIDTH
DUCT
38.1
(4) 14.224 DIA.
MTG. HOLES
NOTE 1
BL
101.6 45ø
50.8
"SD"
DIA. SHAFT
TA
NOTE 1
ROTATION
MOTOR
"FR"
MAX. FRAME
"TH"
HOUSING
GAGE
SUPPORT
LEGS
FOUR PLACES
(NOTE 2)
45ø
"NH" NUMBER OF
"DH" DIA. HOLES
ON "CB" DIA. B.C.
EQUALLY SPACED
STRADDLING
CENTER LINE
AIR
FLOW
MC
MAX
VIEWED FROM OUTLET END
TYPE "QSL" VERTICAL UP DISCHARGE WITH FLOOR MOUNT SUPPORT LEGS
AIR
FLOW
AIR
FLOW
VUI
AIR
FLOW
NOTES:
1. One locking collar and impeller hub cap included
to prevent shifting of components.
2. Support legs shown are provided as an accessory.
AIR
FLOW
DISCHARGE UP
FLOOR MOUNT
UP
VUO DISCHARGE
CEILING HUNG
VDI
DISCH. DOWN
CEILING HUNG
DOWN
VDO DISCH.
FLOOR MOUNT
SIZE
BL
BT
CA
CB
CC
DH
FR
MC
NH
150
165
182
200
222
245
270
300
330
365
402
445
490
542
645
710
838
899
965
1051
1137
1267
1372
1492
1645
1791
1946
2153
165
165
165
184
203
227
248
278
305
337
375
413
457
505
514
567
627
687
764
842
927
1030
1134
1254
1381
1529
1683
1864
562
619
679
740
816
892
978
1096
1200
1321
1461
1607
1762
1956
594
654
711
770
848
924
1010
1140
1245
1365
1518
1664
1819
2026
14
18
18
21
21
21
21
21
21
21
21
21
21
21
132M
132M
160L
160L
160L
180L
180L
200L
200L
225M
225M
250M
250M
280M
654
704
875
919
956
962
1071
1146
1183
1308
1518
1580
1719
1816
8
8
12
12
12
12
12
16
16
16
16
16
24
24
SD
CLI
25
25
25
30
30
35
35
35
42
50
50
50
55
65
CLII
30
35
35
35
35
42
42
50
55
55
55
65
65
70
TA
TH
705
771
861
945
1021
1125
1240
1386
1521
1686
1854
2056
2235
2507
10
10
12
12
12
12
12
10
10
10
10
10
10
10
QSL-AC1000024F
QSLR-AC1001675B
QSLSH-AC1001667C
DIMENSIONS ARE SUBJECT TO CHANGE. CERTIFIED DRAWINGS AVAILABLE ON REQUEST.
WWW.TCF.COM
27
DIMENSIONAL DATA
Vertical Roof
"NH" NUMBER OF
"DH" DIA. HOLES
ON "CB" DIA. B.C.
EQUALLY SPACED
STRADDLING
CENTER LINE
O.D. DISCH. CAP
CG
"A"
DISCHARGE CAP
O.D.
AIR
FLOW
DUCT
"SD" DIA. SHAFT
"BT" BELT TUBE WIDTH
CA
NOTE 1
CH
INSIDE
FLANGE
CK
CC
"A"
TA
NOTE 1
25.4
MC
MAX
"TH"
HOUSING
GAGE
VIEW "A" - "A"
W/O DISCHARGE CAP
MOTOR
"FR" MAX. FRAME
CJ
CURB CAP
69.85
CD
50.8
O.D. HSG
CE
INSIDE SQ.
TYPE "QSL" VERTICAL DISCHARGE WITH DISCHARGE CAP AND CURB CAP
NOTES:
1. One locking collar and impeller hub cap included to prevent shifting of components.
2. Discharge cap and curb cap are optional accessories.
SIZE
BL
BT
CA
CB
CC
CD
CE
CG
CH
CJ
CK
DH
FR
MC
NH
150
165
182
200
222
245
270
300
330
365
402
445
490
542
645
710
838
899
965
1051
1137
1267
1372
1492
1645
1791
1946
2153
165
165
165
184
203
227
248
278
305
337
375
413
457
505
514
567
627
687
764
842
927
1030
1134
1254
1381
1529
1683
1864
562
619
679
740
816
892
978
1096
1200
1321
1461
1607
1762
1956
594
654
711
770
848
924
1010
1140
1245
1365
1518
1664
1819
2026
521
573
632
692
768
846
932
1037
1140
1261
1388
1535
1689
1870
695
784
886
949
1026
1102
1187
1295
1400
1521
1648
1769
1981
2254
762
813
864
1016
1016
1168
1168
1346
1499
1524
1702
1854
2032
2197
1238
1395
1486
1649
1726
1913
2034
2268
2480
2645
2896
3186
3505
4002
152
160
168
171
171
178
184
197
197
197
203
216
229
235
381
457
457
533
533
610
610
686
762
762
838
914
1016
1261
14
18
18
21
21
21
21
21
21
21
21
21
21
21
132M
132M
160L
160L
160L
180L
180L
200L
200L
225M
225M
250M
250M
280M
654
704
875
919
956
962
1071
1146
1183
1308
1518
1580
1719
1816
8
8
12
12
12
12
12
16
16
16
16
16
24
24
SD
CLI
25
25
25
30
30
35
35
35
42
50
50
50
55
65
CLII
30
35
35
35
35
42
42
50
55
55
55
65
65
70
TA
TH
705
771
861
945
1021
1125
1240
1386
1521
1686
1854
2056
2235
2507
10
10
12
12
12
12
12
10
10
10
10
10
10
10
QSL-AC1000567B
QSLR-AC1001673B
QSLSH-AC1001674B
DIMENSIONS ARE SUBJECT TO CHANGE. CERTIFIED DRAWINGS AVAILABLE ON REQUEST.
28
TWIN CITY FAN - CATALOGUE M1060
TYPICAL SPECIFICATIONS
Model
QSL
Fans shall be Type QSL (standard mixed flow) of the non-overloading design, as manufactured by Twin City Fan
Companies.
PERFORMANCE — Performance ratings shall conform to AMCA Standard 205 (fan efficiency grade), 211 (air performance)
and 311 (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 210 (air performance) and
300 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings
seal for both sound and air, and fan efficiency grade (FEG). Sound certification shall apply to both inlet and outlet
sound power levels.
Fans shall be designed for maximum efficiency. Fans shall have a sharply rising pressure characteristic extending
through the operating range and continuing to rise well beyond the efficiency peak to assure quiet and stable operation
under all conditions. Power characteristics shall be truly self-limiting and shall reach a peak in the normal selection area.
Model QSL shall be available UL 705 listed. Fans shall bear a permanently attached nameplate displaying model and
serial number of the unit for future identification.
HOUSING — Housings shall be cylindrical and welded steel throughout. Inlets shall be fully streamlined. Housings shall
be suitably braced to prevent vibration or pulsation. Totally enclosed belt guard shall enclose motor sheave and V-belt
drives. Punched inlet and outlet flanges shall be equipped for duct mounting. Extended lube lines shall be provided for
ease of lubrication. Model QSL shall include bolted access door for inspection and maintenance of impeller.
IMPELLER — Fan impellers shall have die-formed hollow aerofoil blades designed for maximum efficiency, and quiet
and stable operation. Blades shall be continuously welded to the back plate and impeller cone. Impellers shall be
statically and dynamically balanced and the complete fan assembly including motor and drive shall be test balanced at
or near the operating speed at the factory prior to shipment.
SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for
accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed.
BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type
and selected for a minimum L-10 life of 40,000 hours at the maximum fan RPM. Bearings shall be equipped with
extended lubrication lines with grease fittings outside of the fan housing.
DRIVE — Motor sheaves shall be cast iron, variable pitch on applications 7.5 kW and smaller, and fixed pitch on 11
kW and larger.
INLET VANES — Inlet vanes, where specified, shall be of the nested design. Inlet vanes shall be designed for
economical, stable, and efficient air volume control at partial load conditions.
FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and de-burred
before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall
be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum
components shall be unpainted.
FACTORY RUN TEST — All fans with motors and drives mounted by Twin City Fan & Blower shall be completely
assembled and test run as a unit at the specified operating speed prior to shipment. Each impeller shall be statically
and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan
Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment
in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy
shall be available upon request.
GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its QSL Mixed Flow Fans for at
least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.
WWW.TCF.COM
29
TYPICAL SPECIFICATIONS
Model
QSLR
Fans shall be Type QSLR (restaurant) of the non-overloading design, as manufactured by Twin City Fan Companies.
PERFORMANCE — Performance ratings shall conform to AMCA Standard 205 (fan efficiency grade), 211 (air performance)
and 311 (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 210 (air performance) and
300 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings
seal for both sound and air, and fan efficiency grade (FEG). Sound certification shall apply to both inlet and outlet
sound power levels.
Fans shall be designed for maximum efficiency. Fans shall have a sharply rising pressure characteristic extending
through the operating range and continuing to rise well beyond the efficiency peak to assure quiet and stable operation
under all conditions. Power characteristics shall be truly self-limiting and shall reach a peak in the normal selection area.
Model QSLR shall be UL 762 listed for the exhaust of grease-laden air. Fans shall bear a permanently attached
nameplate displaying model and serial number of the unit for future identification.
HOUSING — Housings shall be cylindrical and welded steel throughout. Inlets shall be fully streamlined. Housings shall
be suitably braced to prevent vibration or pulsation. Totally enclosed belt guard shall enclose motor sheave and V-belt
drives. Punched inlet and outlet flanges shall be equipped for duct mounting. Extended lube lines shall be provided for
ease of lubrication. Model QSLR shall include a belt tube, 2 impeller cleanout doors (located 180° apart) for inspection
and maintenance of the impeller and a 2" drain.
IMPELLER — Fan impellers shall have die-formed hollow aerofoil blades designed for maximum efficiency, and quiet
and stable operation. Blades shall be continuously welded to the back plate and impeller cone. Impellers shall be
statically and dynamically balanced and the complete fan assembly including motor and drive shall be test balanced at
or near the operating speed at the factory prior to shipment. Impellers on model QSLR shall have cooling fins to draw
cool air over shaft and bearings.
SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for
accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed.
BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type
and selected for a minimum L-10 life of 40,000 hours at the maximum fan RPM. Bearings shall be equipped with
extended lubrication lines with grease fittings outside of the fan housing.
DRIVE — Motor sheaves shall be cast iron, variable pitch on applications 7.5 kW and smaller, and fixed pitch on 11
kW and larger.
INLET VANES — Inlet vanes, where specified, shall be of the nested design. Inlet vanes shall be designed for
economical, stable, and efficient air volume control at partial load conditions.
FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and de-burred
before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall
be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum
components shall be unpainted.
FACTORY RUN TEST — All fans with motors and drives mounted by Twin City Fan & Blower shall be completely
assembled and test run as a unit at the specified operating speed prior to shipment. Each impeller shall be statically
and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan
Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment
in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy
shall be available upon request.
GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its QSLR Mixed Flow Fans for at
least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.
30
TWIN CITY FAN - CATALOGUE M1060
TYPICAL SPECIFICATIONS
Model
QSLSH
Fans shall be Type QSLSH (smoke and heat) of the non-overloading design, as manufactured by Twin City Fan
Companies.
PERFORMANCE — Performance ratings shall conform to AMCA Standard 205 (fan efficiency grade), 211 (air performance)
and 311 (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 210 (air performance) and
300 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings
seal for both sound and air, and fan efficiency grade (FEG). Sound certification shall apply to both inlet and outlet
sound power levels.
Fans shall be designed for maximum efficiency. Fans shall have a sharply rising pressure characteristic extending
through the operating range and continuing to rise well beyond the efficiency peak to assure quiet and stable operation
under all conditions. Power characteristics shall be truly self-limiting and shall reach a peak in the normal selection area.
Model QSLSH shall be UL listed for Smoke Control Systems ((250°C for 4 hours and 525°C for 15 minutes). Fans shall
bear a permanently attached nameplate displaying model and serial number of the unit for future identification.
HOUSING — Housings shall be cylindrical and welded steel throughout. Inlets shall be fully streamlined. Housings shall
be suitably braced to prevent vibration or pulsation. Totally enclosed belt guard shall enclose motor sheave and V-belt
drives. Punched inlet and outlet flanges shall be equipped for duct mounting. Extended lube lines shall be provided for
ease of lubrication. Model QSLSH shall include a belt tube for the protection of belts and drive components from the
airstream and bolted access door.
IMPELLER — Fan impellers shall have die-formed hollow aerofoil blades designed for maximum efficiency, and quiet
and stable operation. Blades shall be continuously welded to the back plate and impeller cone. Impellers shall be
statically and dynamically balanced and the complete fan assembly including motor and drive shall be test balanced at
or near the operating speed at the factory prior to shipment. Impellers on model and QSLSH shall have cooling fins to
draw cool air over shaft and bearings.
SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for
accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed.
BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type
and selected for a minimum L-10 life of 40,000 hours at the maximum fan RPM. Bearings shall be equipped with
extended lubrication lines with grease fittings outside of the fan housing.
DRIVE — Motor sheaves shall be cast iron, variable pitch on applications 7.5 kW and smaller, and fixed pitch on 11
kW and larger. Model QSLSH shall be equipped with a two-groove drive minimum.
INLET VANES — Inlet vanes, where specified, shall be of the nested design. Inlet vanes shall be designed for
economical, stable, and efficient air volume control at partial load conditions.
FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and de-burred
before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall
be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum
components shall be unpainted.
FACTORY RUN TEST — All fans with motors and drives mounted by Twin City Fan & Blower shall be completely
assembled and test run as a unit at the specified operating speed prior to shipment. Each impeller shall be statically
and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan
Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment
in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy
shall be available upon request.
GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its QSLSH Mixed Flow Fans for
at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.
WWW.TCF.COM
31
INDUSTRIAL & COMMERCIAL FANS
Centrifugal Fans | Utility Sets | Plenum & Plug Fans | Inline Centrifugal Fans
Mixed Flow Fans | Tubeaxial & Vaneaxial Fans | Propeller Wall Fans | Propeller Roof Ventilators
Centrifugal Roof & Wall Exhausters | Ceiling Ventilators | Gravity Ventilators | Duct Blowers
Radial Bladed Fans | Radial Tip Fans | High Efficiency Industrial Fans | Pressure Blowers
Laboratory Exhaust Fans | Filtered Supply Fans | Mancoolers | Fiberglass Fans | Custom Fans
TWIN CITY FAN & BLOWER | WWW.TCF.COM
5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601
©2015 Twin City Fan Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog images cover the general appearance of Twin City Fan &
Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement