x Permasolid 2K Midcoats MC 0001, MC 0002

x Permasolid 2K Midcoats MC 0001, MC 0002
Technical Data Sheet – 996.0
2K Tinted Midcoat Repair Process
GENERAL
DESCRIPTION
2K tinted midcoats: Permasolid® 2K Diamond Midcoat, MC 0001, or Permasolid® 2K Transparent Red
Midcoat, MC 0002, will be needed in combination with Permasolid® Low VOC Clear Coat 8096, used
as an untinted blending clear, to repair various special OEM colors. These tinted midcoats can be
used over either Permacron® Base Coat Series 293/295 or Permahyd® Hi-TEC 480.
The products referenced herein may not be sold in your market. Please consult your
distributor for product availability.
MIXING
COMPONENTS
Refer to Mix Tables below.
MIX RATIO
PERMASOLID HS HARDENERS
Refer to Mix Tables below
PERMASOLID VHS HARDENERS
Refer to Mix Tables below.
PERMASOLID LOW VOC HARDENERS
Component
MC 0001 or MC 0002
3192 / 3194 / 3196
3394 / 3392
Volume
2
1
+10-15%
ELASTIC TINTED MIDCOAT - PERMASOLID LOW VOC HARDENERS
MC 0001 or MC 0002
2
9050
+15%
3192 / 3194 / 3196
1
3394 / 3392
+10-15%
PERMASOLID HS HARDENERS
Mixing Information for MC 0001, MC 0002, or 8096 with HS Hardeners
Component
MC 0001, MC
0002, or 8096
3307, 3309,
3310, 3315,
3320, or 3325
3363, 3365,
or 8580
Pint
Pint
Pint
Quart
Quart
Quart
5%
Reduction
10%
Reduction
15%
Reduction
5%
Reduction
10%
Reduction
15%
Reduction
289.6
276.5
264.5
579.3
553.0
528.9
182.9
174.6
167.0
365.8
349.2
334.0
20.3
38.8
55.7
40.7
77.6
111.4
Page 1 of 8
Technical Data Sheet – 996.0
Mixing Information for Elastic MC 0001, MC 0002, or 8096 with HS Hardeners
Component
Pint
Pint
Pint
Quart
Quart
Quart
5%
Reduction
10%
Reduction
15%
Reduction
5%
Reduction
10%
Reduction
15%
Reduction
MC 0001, MC
0002, or 8096
251.9
240.4
230.0
503.7
480.8
459.9
9050 (15%)
38.8
37.1
35.5
77.7
74.1
70.9
182.9
174.6
167.0
365.8
349.2
334.0
20.3
38.8
55.7
40.7
77.6
111.4
3307, 3309,
3310, 3315,
3320, or 3325
3363, 3365, or
8580
PERMASOLID VHS HARDENERS
Mixing Information for MC 0001, MC 0002, or 8096 with VHS Hardeners
Component
MC 0001, MC
0002, or 8096
3220, 3230, 3240,
or 3245
3363, 3365, or
8580
Pint
Pint
Quart
Quart
20%
Reduction
25%
Reduction
20%
Reduction
25%
Reduction
301.7
289.6
603.4
579.3
120.8
116.0
241.6
232.0
71.2
85.5
142.5
171.0
Mixing Information for Elastic MC 0001, MC 0002, or 8096 with VHS Hardeners
Component
Pint
Pint
Quart
Quart
20%
Reduction
25%
Reduction
20%
Reduction
25%
Reduction
MC 0001, MC
0002, or 8096
262.4
251.9
524.7
503.7
9050 (15%)
40.5
38.8
80.9
77.7
120.8
116.0
241.6
232.0
71.2
85.5
142.5
171.0
3220, 3230,3240,
or 3245
3363, 3365, or
8580
APPLICATION VISCOSITY
15-16 seconds at 68°F/20°C, DIN 4
POT LIFE
Approximately 0.5-1 hour at 68°F/20°C when ready to spray
SPECIAL TIPS
1. 15% Permasolid® Elastic Additive 9050 can be added to both the Permasolid® tinted midcoat
and the Permasolid® Low VOC Clear Coat 8096. Permasolid® Elastic Additive 9050 must be
mixed with the tinted midcoat or untinted clear coat prior to the addition of hardener and
reducer. Note: If Permasolid® Elastic Additive 9050 is added to the tinted midcoat, it should
Page 2 of 8
Technical Data Sheet – 996.0
also be added in the same amount to the Permasolid® Low VOC Clear Coat 8096 and the
final clear coat.
APPLICATION
SUBSTRATES
Permacron® Base Coat Series 293/295 (ground coat)
(See Technical Data Sheet 970.10 or 970.13)
Permahyd® Hi-TEC 480 (ground coat)
(See Technical Data Sheet 480)
SPRAYGUN SETUP
HVLP
Approved Transfer Efficiency
1.3-1.4mm
1.2-1.3mm
Please refer to gun manufacturer and local legislation for proper spray pressure recommendations.
APPLICATION

1-3 coats as needed for color match with 2-5 minutes intermediate flash-off between coats if more
than 1 coat is required.
2K Tinted Midcoat Repair Process with Permacron® Base Coat Series 293/295
1. Check color:
Create a let-down panel to establish
# of coats of tinted midcoat needed
for color match.
2. Base coat application:
Mask the blend panel to protect
blend area from overspray
(optional).
Apply Permacron® Base Coat
Series 293/295.
For flash-off times, please refer to the
Permacron® Base Coat Series
293/295 TDS.
3. Blending the base coat:
Remove the masking paper if used.
Blend the base coat normally.
(Refer to Permacron® Base Coat
Series 293/295 TDS)
Pay close attention to overspray drift.
For flash-off times, please refer to the
Permacron® Base Coat Series 293/295 TDS.
Proceed to Step 4.
Page 3 of 8
Technical Data Sheet – 996.0
OR
2K Tinted Midcoat Repair Process with Permahyd® Hi-TEC 480
1. Check color:
Create a let-down panel to establish
# of coats of tinted midcoat needed
for color match.
2. Base coat application:
Mask the blend panel to protect
blend area from overspray (optional).
Apply Permahyd® Hi-TEC 480.
Apply base coat
1.5 coats
For flash-off times, please refer to
the Permahyd® Hi-TEC 480 TDS
3. Blending the basecoat:
Remove the masking paper.
Apply Permahyd® Blending Additive
1050 or 1051. Do not allow to flash.
Blend Permahyd® Hi-TEC 480 into
adjacent panel, spraying with reduced
pressure (minimum 20-24 psi).
Pay close attention to avoid overspray
drift. Use outside in blend technique.
Proceed to Step 4.
Blending the base coat
1 spray operation
For flash-off times, please refer to
the Permahyd® Hi-TEC 480 TDS
Page 4 of 8
Technical Data Sheet – 996.0
4. Blending the tinted midcoat:
Recoat the base coat with a single
coat of tinted midcoat and verify color
match. Apply additional coat(s) of tinted
midcoat with minimal flash (2 – 5
minutes between coats), as needed to
achieve color match (generally only 2
coats are required).
Fade out zone of the
tinted midcoat.
Important Note: The tinted midcoat should
not be applied over the entire blend panel
or a darker color will result at the end of
the panel.
Stagger tinted midcoat with each
new application for best results.
5. Blending the clear coat:
Apply a single application of
Permasolid® Low VOC Clear Coat
8096 (untinted) from outside in.
Blend the Permasolid® Low VOC
Clear Coat 8096 wet-on-wet into
the tinted midcoat.
Fade out zone of the
tinted midcoat.
Permasolid® Low
VOC Clear Coat
8096 - untinted
See Permasolid® Low VOC Clear Coat 8096 TDS.
Page 5 of 8
Technical Data Sheet – 996.0
DRY TIMES
LOW BAKE
Flash-off time:
Drying time at 130°F/55°C metal temperature:
0-5 minutes
15 minutes
6. After bake, allow panel(s) to cool completely.
A careful intermediate sanding with P1000-P2000 is optional.
APPLICATION
7. Apply 1.5-2.0 coats of Permacron® or Permasolid® clear coat.
DRY TIMES
Refer to the TDS of the respective Permacron® or Permasolid® clear coat.
PHYSICAL PROPERTIES
Coating Category: Color Coating (HS Hardeners)
Max. VOC (AP): 407 g/l; 3.4 lbs/gal
Max. VOC (LE): 467 g/l; 3.9 lbs/gal
Avg. Gallon Weight: 1041.0 g/l; 8.69 lbs/gal
Avg. Weight % Volatiles: 53.9%
Avg. Weight % Water: 0.0%
Avg. Weight % Exempt Solvent: 14.5%
Avg. Volume % Water: 0.0%
Avg. Volume % Exempt Solvent: 12.5%
Theoretical Coverage: 670.3 sq. ft. @ 1 mil
Theoretical Coverage @ Recommended Film Build: 335.2 sq. ft.
Coating Category: Color Coating (HS Hardeners, Elastic Additive)
Max. VOC (AP): 407 g/l; 3.4 lbs/gal
Max. VOC (LE): 467 g/l; 3.9 lbs/gal
Avg. Gallon Weight: 1042.9 g/l; 8.70 lbs/gal
Avg. Weight % Volatiles: 52.1%
Avg. Weight % Water: 0.0%
Avg. Weight % Exempt Solvent: 12.6%
Avg. Volume % Water: 0.0%
Avg. Volume % Exempt Solvent: 10.9%
Theoretical Coverage: 696.7 sq. ft. @ 1 mil
Theoretical Coverage @ Recommended Film Build: 348.4 sq. ft.
Page 6 of 8
Technical Data Sheet – 996.0
Coating Category: Color Coating (VHS Hardeners)
Max. VOC (AP): 372 g/l; 3.1 lbs/gal
Max. VOC (LE): 431 g/l; 3.6 lbs/gal
Avg. Gallon Weight: 1046.5 g/l; 8.73 lbs/gal
Avg. Weight % Volatiles: 51.8%
Avg. Weight % Water: 0.0%
Avg. Weight % Exempt Solvent: 15.8%
Avg. Volume % Water: 0.0%
Avg. Volume % Exempt Solvent: 13.7%
Theoretical Coverage: 706.4 sq. ft. @ 1 mil
Theoretical Coverage @ Recommended Film Build: 353.2 sq. ft.
Coating Category: Color Coating (VHS Hardeners, Elastic Additive)
Max. VOC (AP): 372 g/l; 3.1 lbs/gal
Max. VOC (LE): 431 g/l; 3.6 lbs/gal
Avg. Gallon Weight: 1048.8 g/l; 8.75 lbs/gal
Avg. Weight % Volatiles: 49.7%
Avg. Weight % Water: 0.0%
Avg. Weight % Exempt Solvent: 13.7%
Avg. Volume % Water: 0.0%
Avg. Volume % Exempt Solvent: 11.9%
Theoretical Coverage: 706.4 sq. ft. @ 1 mil
Theoretical Coverage @ Recommended Film Build: 353.2 sq. ft.
Coating Category: Color Coating (Low VOC Hardeners)
Max. VOC (AP): 156 g/l; 1.3 lbs/gal
Max. VOC (LE): 240 g/l; 2.0 lbs/gal
Avg. Gallon Weight: 1140.1 g/l; 9.51 lbs/gal
Avg. Weight % Volatiles: 54.3%
Avg. Weight % Water: 0.0%
Avg. Weight % Exempt Solvent: 41.0%
Avg. Volume % Water: 0.0%
Avg. Volume % Exempt Solvent: 36.2%
Theoretical Coverage: 728.5 sq. ft. @ 1 mil
Theoretical Coverage @ Recommended Film Build: 364.3 sq. ft.
Coating Category: Color Coating (Low VOC Hardeners, Elastic
Additive)
Max. VOC (AP): 156 g/l; 1.3 lbs/gal
Max. VOC (LE): 240 g/l; 2.0 lbs/gal
Avg. Gallon Weight: 1142.1 g/l; 9.53 lbs/gal
Avg. Weight % Volatiles: 52.4%
Avg. Weight % Water: 0.0%
Avg. Weight % Exempt Solvent: 38.9%
Avg. Volume % Water: 0.0%
Avg. Volume % Exempt Solvent: 34.4%
Theoretical Coverage: 757.8 sq. ft. @ 1 mil
Theoretical Coverage @ Recommended Film Build: 378.9 sq. ft.
VOC REG ULATED AREAS
These directions refer to the use of products which may be restricted or require special mixing
instructions in VOC regulated areas. Follow mixing usage and recommendations in the VOC Compliant
Products Chart for your area.
Page 7 of 8
Technical Data Sheet – 996.0
SAFETY AND HANDLING
For industrial use only by professional, trained painters. Not for sale to or use by the general public.
Before using, read and follow all label and MSDS precautions. If mixed with other components, mixture
will have hazards of all components.
Ready to use paint materials containing isocyanates can cause irritation of the respiratory organs and
hypersensitive reactions. Asthma sufferers, those with allergies and anyone with a history of
respiratory complaints must not be asked to work with products containing isocyanates.
Do not sand, flame cut, braze or weld dry coating without a NIOSH approved air purifying respirator
with particulate filters or appropriate ventilation, and gloves.
Any analytical results set forth herein do not constitute a warranty of specific product features or of the
product’s suitability for a specific purpose. All products are sold pursuant to our general conditions of
sale. We hereby disclaim all warranties and representations, express or implied, with respect to this
product, including any warranty of merchantability or fitness for a particular purpose. This product is
protected by patent law, trademark law, copyright law, international treaties and/or other applicable
law. All rights reserved. Unauthorized sale, manufacturing or use may result in civil and criminal
penalties.
Revised: August 2015
Page 8 of 8
©2015 Axalta Coating Systems, LLC and all affiliates. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement