Pub. 42004-451A GAI-TRONICS® CORPORATION A HUBBELL COMPANY Model 13314-004 Div. 2 Hazardous Area 100-Volt Horn Driver Confidentiality Notice This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAITronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party. Introduction The GAI-Tronics Model 13314-004 Div. 2 Hazardous Area 100-Volt Horn Driver is constructed of black glass and fiber-reinforced polyester thermoplastic and has a rain-tight construction. It is built to withstand harsh industrial environments and is approved for installation in hazardous areas. Mounting Instructions A typical installation of a 13314 Series Driver with associated horn and mounting assembly is shown in Figure 3. The recommended mounting height for the driver is 9 feet (2.7 meters) from the floor. Refer to the following chart to verify that the horn is paired with the correct speaker mounting assembly. Horn Series Speaker Mounting Assembly 13302 411A 13304 411A 13305 411A 13306 414-002 13309 411A 13340 411A Figure 1. Model 13314-004 Div. 2 Hazardous Area 100-Volt Horn Driver GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA 610-777-1374 800-492-1212 Fax: 610-796-5954 VISIT WWW .GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS Pub. 42004-451A Page: 2 of 4 Model 13314-004 Div. 2 Hazardous Area 100-Volt Horn Driver Figure 2. Typical Installation The installation of this speaker assembly must conform to regulations governing electrical equipment for hazardous locations and provisions of the National Electrical Code. Install the mounting assembly and the horn, then complete the following instructions to install the driver onto the horn. Wiring Instructions Refer to the following chart to determine the appropriate gauge speaker cable. Cable Options Distance of Cable Run in Feet No. 18 AWG 8,900 No. 16 AWG 14,000 No. 14 AWG 22,500 Field wiring to the driver must be made using the attached three-conductor type SO cord. Connect these wires as follows: • Green: earth ground • Black: amplifier 100V + terminal • White: amplifier 100V − (com) terminal The horn driver is factory-connected for 30-watt tap setting. If no wattage tap changes are required, screw the driver assembly onto the rear of the horn as shown in Figure 2. f:\standard ioms - current release\42004 instr. manuals\42004-451a.doc 05/11 Model 13314-004 Div. 2 Hazardous Area 100-Volt Horn Driver Pub. 42004-451A Page: 3 of 4 Changing the Wattage Tap Setting 1. If another wattage tap setting is desired, it is recommended that the driver assembly be disconnected and removed from the horn for convenience of changing taps. 2. Remove the three Phillips screws that hold the driver together, and pull the rear assembly away from the front assembly. See Figure 3. Use care to avoid damaging the gasket. Figure 3. Driver Outline Diagram 3. Unscrew the wire nut from the driver transformer’s brown wire that is joined to the driver cable’s (SO cable) black wire. Terminate the brown wire with a nut or approved connector to avoid shorting out. 4. Select the desired wattage tap wire, as shown in Figure 3. 5. Strip the wire back approximately 3/8 inch. Connect the desired wattage tap wire to the driver cable’s black wire using a wire nut or approved connector. 6. It is not recommended that these wires be cut in case of future changes. Carefully push all primary transformer wires into the space in the rear section of the enclosure. 7. After ensuring that the gasket is properly seated on the front assembly, align the rear assembly holes with the front assembly holes and re-install the three screws. 8. Re-install the driver assembly to the horn and reconnect the cable to the field connection. f:\standard ioms - current release\42004 instr. manuals\42004-451a.doc 05/11 Model 13314-004 Div. 2 Hazardous Area 100-Volt Horn Driver Pub. 42004-451A Page: 4 of 4 Driver Specifications Power handling ...................... 30 WRMS 300–3000 Hz; pink noise 6 dB crest factor; ref. ANSI S4.26–1984 Frequency response..................................................................................... 300–4500 Hz (depends on horn) Input taps for 100 V line................................................ 3.7, 7.5, 15, and 30 watts (factory set for 30 watts) Sensitivity ........................................... 109 dB spl @ 1 watt, 1 meter; swept sine average with 13304 Horn Horn coupling ...........................................................................................Standard 1.375–18 UNEF threads Housing................................................................ Black; glass and fiber reinforced polyester thermoplastic Bushing .......................................................................................... Nylon body with neoprene sealing gland Cable ......................................Extra hard usage flexible cord (Type SO, 18/3) 42 inches (1066.8 mm) long Impedance ...................................................................................................................Variable (transformer) Shipping weight .................................................................................................................... 4.3 lbs. (1.9 kg) Dimensions ....................................................5.0 inches (127 mm) in diameter × 5.5 inches (140 mm) long Approvals...................UL & cUL Listed for Class I, Div. 2 Groups A, B, C, D – Temp Code T2C at +40C Class I, Div. 2 Groups A, B, C, D – Temp Code T2B at +55C Class II, Div. 2 Groups F & G – Temp Code T4 at +55C Class III, Div. 2 Weatherproof rating.......................................................................................................................... Type 4X f:\standard ioms - current release\42004 instr. manuals\42004-451a.doc 05/11 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document. If (a) Seller’s goods prove to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above, Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time they will be repaired or replaced, at Seller’s option, without charge to Buyer. Repair or replacement shall be Buyer’s sole and exclusive remedy. The warranty period on any repaired or replacement equipment shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original equipment was shipped. In no event shall GAI-Tronics warranty obligations with respect to equipment exceed 100% of the total cost of the equipment supplied hereunder. Buyer may also be entitled to the manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder. The applicability of any such third-party warranty will be determined by GAI-Tronics. Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors, shall be performed in accordance with the standard of care with which such services are normally provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work site. Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAITronics warranty obligations with respect to services exceed 100% of the total cost of the services provided hereunder. Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above. Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods, every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a reasonable time after such latent defect is or should have been discovered by Buyer. Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Return Policy If the equipment requires service, contact your Regional Service Center for a return authorization number (RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a purchase order number. If the equipment is under warranty, repairs or a replacement will be made in accordance with the warranty policy set forth above. Please include a written explanation of all defects to assist our technicians in their troubleshooting efforts. Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the Regional Service Center closest to you. (Rev. 10/06)
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement