P2... Series Pressure Independent Characterized Control Valves™ (PICCV) Chrome Plated Brass Ball and Brass Stem, NPT Female Ends Application The Pressure Independent Characterized Control Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications include unit ventilators and VAV reheat coils. This valve is suitable for use in a hydronic system with constant or variable flow. This valve is designed with MFT functionality which facilitates the use of various control input. 1” Rangeability Differential pressure Valve accuracy Weight of valve body 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 ½” body has two different flow capacities (.50 GPM to 2.5 GPM) (3 GPM to 5.5 GPM) 1” body has two different flow capacities (11 GPM to 16 GPM) (17 GPM to 19 GPM) Tefzel® and Teflon® are registered trademarks of Dupont 800-543-9038 USA 8 866-805-7089 CANADA 203-791-8396 LATIN AMERICA LRCB24-3 Heat Pump Only 15 15 15 15 15 15 15 15 15 15 15 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 25 25 25 LRX24-MFT ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ ¾ 1 1 1 1 1 1 1 1 1 LRB(X)24-3 0.03 0.06 0.09 0.13 0.16 0.19 0.22 0.25 0.28 0.32 0.35 0.38 0.41 0.44 0.47 0.50 0.54 0.57 0.60 0.63 0.69 0.76 0.82 0.88 0.95 1.01 1.07 1.14 1.20 Non-Spring Return TF24-MFT US 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 11 12 13 14 15 16 17 18 19 LF24-MFT US P2050B005 P2050B010 P2050B015 P2050B020 P2050B025 P2050B030 P2050B035 P2050B040 P2050B045 P2050B050 P2050B055 P2075B060 P2075B065 P2075B070 P2075B075 P2075B080 P2075B085 P2075B090 P2075B095 P2075B100 PICCV-25-011 PICCV-25-012 PICCV-25-013 PICCV-25-014 PICCV-25-015 PICCV-25-016 PICCV-25-017 PICCV-25-018 PICCV-25-019 Spring Return M40019 - 06/10 - Subject to change. © Belimo Aircontrols (USA), Inc. ¾” 0.5 GPM [.03 l/s], 1 GPM [.06 l/s], 1.50 GPM [0.09 l/s], 2 GPM [.13 l/s], 2.5 GPM (0.16 l/s) , 3 GPM [.19 l/s], 3.5 GPM( 0.22 l/s), 4 GPM [.25 l/s], 4.5 GPM (0.28 l/s), 5 GPM [.32 l/s], 5.5 GPM (0.35 l/s) 6 GPM [0.37 l/s], 6.5 GPM (0.41 l/s), 7 GPM [0.44 l/s], 7.5 GPM (0.47 l/s) 8 GPM [0.50 l/s], 8.5 GPM (0.54 l/s), 9 GPM [0.57 l/s], 9.5 GPM (0.60 l/s) 10 GPM [0.63 l/s] 11 GPM (0.69 l/s), 12 GPM [0.76 l/s], 13 GPM (0.82), 14 GPM [0.88 l/s], 15 GPM (0.95 l/s), 16 GPM [1.01 l/s], 17 GPM (1.07 l/s), 18 GPM [1.14 l/s] 19 GPM (1.20 l/s) 100 : 1 5 to 50 PSI operating range ± 10% combination of manufacturing tolerances and pressure variations ½” = 2.52 lbs ¾” = 2.52 lbs 1” = 4.98 lbs Close-off PSI Flow rate ½” DN mm Regulator components Spring Body pressure rating Media temp. range Close off pressure Leakage forged brass, nickel plated chrome plated brass chrome plated brass Viton fiberglass reinforced Teflon® PTFE ½” & ¾” Brass 1” TEFZEL® 2 EPDM O-rings, lubricated ½” & ¾” silicone and Nomex 1” polyester reinforced silicone stainless steel/brass/Delrin 500 AF stainless steel 600 PSI 0°F to 212°F [-18°C to 100°C] 200 PSI ANSI Class IV (0.01% of rated valve capacity at 50 psi differential) Inches Packing Diaphragm chilled or hot water, 60% glycol equal percentage ½”, ¾”, 1” female, NPT Valve Model Liter/sec Technical Data Service Flow characteristic Size Type of end fitting Materials Body Ball Stem Seat O-rings Seat Characterizing disc Suitable Actuators GPM Flow Rate Valve Nominal Size LF24-MFT Actuators, Multi-Function Technology 3.78" [96] D128 Dimensions with PICCV 7.64" [194] 2.28" [58] 4.49" [114] C D B Models Valve Nominal Size DN In. [mm] LF24-MFT US LF24-MFT-S US w/built-in Aux. Switch Technical Data Control Control signal Power consumption running holding Transformer sizing Electrical connection Overload protection Input impedance Feedback Angle of rotation Direction of rotation spring motor Position indication Running time spring Ambient temperature Housing Agency listings Noise level Quality standard LF24-MFT-S US Auxiliary switch MFT 2 to 10 VDC 2.5 W 1W 5 VA (class 2 power source) 3 ft, 18 GA appliance cables (-S model has 2 cables) ½” conduit connector electronic throughout 0° to 95° rotation 100k Ω for 2 to 10 VDC (0.1 mA) 500 Ω for 4 to 20mA 750 Ω for PWM 500 Ω for on/off and floating point 2 to 10 VDC, 0.5 mA max 95° reversible with CW/CCW mounting switch reversible with built-in visual indicator <40 to 75 sec. (on-off) 100 seconds <25 sec. @-4°F to +122°F [-20°C to +50°C] <60 sec. @-22°F [-30°C] -22° F to 122° F [-30° C to 50° C] NEMA 2 UL 873, CSA C22.2 No. 24 certified, CE max. 62 dB(A) ISO 9001 ½” ¾” after 8/2009 ¾” until 8/2009 1” A Dimensions (Inches [mm]) A B C D E 866-805-7089 CANADA F 15 4.68 [119] 4.47 [114] 4.05 [103] 2.34 [60] 0.99 [25] 0.99 [25] 20 4.90 [125] 4.94 [126] 4.05 [103] 2.34 [60] 0.99 [25] 0.99 [25] 20 5.35 [133] 5.03 [128] 4.22[107] 2.38 [61] 1.04 [26] 1.30 [34] 25 7.05 [179] 6.85 [174] 4.80 [122] 3.23 [82] 1.60 [41] 1.60 [41] 1 x SPDT, 6A (1.5A) @ 250 VAC, UL Listed, adjustable 0° to 95° (double insulated) 800-543-9038 USA 32 F M40019 - 06/10 - Subject to change. © Belimo Aircontrols (USA), Inc. E 203-791-8396 LATIN AMERICA LF24-MFT Actuators, Multi-Function Technology Wiring Diagrams CAUTION Equipment damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 4 IN4004 or IN4007 diode (IN4007 supplied, Belimo part number 40155). 5 6 7 During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W043 2 WARNING Live Electrical Components! 24 VAC/DC Transformer Line Volts (1) Common (2) Hot (3) Y Input (5) U Output Triac A and B can also be contact closures. Position Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VAC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. a (–) Feedback VDC (+) CCW CW …MFT The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. W041 On/Off control 24 VAC Transformer (AC only) (1) Line Volts 7 Position 6 (–) Feedback VDC (+) Common (2) + Hot (3) Y Input (5) U Output CCW CW …MFT M40019 - 06/10 - Subject to change. © Belimo Aircontrols (USA), Inc. W302 PWM, triac source and sink W303 Floating Point control Proportional 2 to 10 or 4 to 20 mA control signal 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 33
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement