Radiačná bezpečnosť
riešenia na presné meranie
Radiation Safety
Product Catalog
2011/2012
451P Pressurized µR Ion
Chamber Survey Meter
190N Portable Neutron
Survey Meter
ASM-990 Advanced
Survey Meter
Fluke Biomedical.
Featuring industry-standard
Victoreen technology
Better products. More choices. One company.
http://www.elso.sk
05-443 PRIMALERT®
Digital Area Monitors
riešenia na presné meranie
Radiation Safety Product Catalog
2011/2012
Providing solutions, not just products
Today, biomeds, physicists, RSO’s, other medical personnel must meet
increasing regulatory pressures, higher quality standards, and rapid technological growth, while performing their work faster and more efficiently than
ever. Fluke Biomedical provides a diverse range of software and hardware
tools to meet today’s challenges.
Service
Fluke Biomedical is dedicated to providing the best service within the
healthcare industry. Equipped with the best-credentialed facilities, onsite
experts, and full asset-management capabilities, Fluke Biomedical’s service team is always on call to take care of its customers. Fluke Biomedical’s
world-class staff leads the industry in post- and pre-sale support, including
helping customers choose the best products and accessories for their needs,
technical support, product calibration, and repairs.
About Fluke
Biomedical
Fluke Biomedical leads the world
in the manufacture of biomedical
test and simulation products,
including standalone electrical
safety testers to fully integrated
and automated performance
testing and documentation
systems. Fluke Biomedical
also provides some of the most
trusted and accurate radiation
safety, medical imaging, and
oncology quality-assurance solutions for regulatory compliance.
Regulatory compliance
Fluke Biomedical’s benchmark quality operates to the most rigorous standards in the industry, including compliance with ISO 9001:2000, ISO
13485:2003, QSR, and NRC/Part 50, Appendix B/Part 21 and adheres to ISO
17025:2005, ANSI Z540, Mammography MQSA and CNSC. Many of the Fluke
Biomedical products are CE-marked and CSA-certified. In addition, the
Global Calibration Laboratory holds its NVLAP Lab Code 200566-0 certification and is traceable to both the NIST & PTB.
Legacy
You may be familiar with some of our legacy brand names, including:
•Victoreen®
• Nuclear Associates
•Keithley
•Metron
• DNI Nevada
• Bio-Tek Instruments
Fluke Biomedical has taken the best elements and products of these former
brands and have incorporated them into the Fluke Biomedical culture and
product line available today.
Our newest catalog
Our Radiation Safety catalog contains a variety of survey meters and probes,
area monitors, and other monitoring accessories that can help Radiation
Safety Officers (RSOs), Health Physicists, Emergency Responders and other
radiation-minded professionals manage diagnostic imaging QA, regulatory
compliance and radiation emergencies.
If you are interested in receiving catalogs or information about
any of Fluke Biomedical’s other product-lines, please visit
www.flukebiomedical.com/catalogs.
Catalogs are also available for the following product lines:
• Biomedical Test
• Imaging and Therapy QA
2
Introduction
http://www.elso.sk
About Fluke
Corporation
Fluke Biomedical is a division
of Fluke Corporation. Fluke
Corporation is the world leader
in the manufacture, distribution, and service of electronic
test tools and software and is
a wholly owned subsidiary of
Danaher Corporation (NYSE:DHR).
riešenia na presné meranie
Radiation Safety Product Catalog
Contents
CarePlans ............................................................................................................................4
Contact information
Ion Chamber Survey Meters
Fluke Biomedical
6045 Cochran Road
Cleveland, OH 44139-3303 U.S.A.
451B Ion Chamber Survey Meter with Beta Slide........................................................ 5
451P Pressurized μR Ion Chamber Survey Meter......................................................... 7
451EXL 451 Assistant for Excel........................................................................................ 9
440RF/D Low Energy RF Shielded Survey Meter....................................................... 10
Other Survey Meters and Probes
ASM-990 Series Advanced Survey Meter................................................................... 11
489-110D GM Pancake Probe......................................................................................... 14
Geiger-Mueller and Scintillation Probe Selection Guide..................................... 15
190N Portable Neutron Survey Meter............................................................................ 18
Area Monitors
190F Area Monitor/Frisker Count Rate Meter.............................................................. 19
05-437 PRIMALERT® 35 Area Radiation Monitor......................................................20
05-443/444 PRIMALERT Digital Area Monitors......................................................... 21
05-450 PRIMALERT Digital Doorway Monitor............................................................22
Personal Dosimetry
05-106 Bleeper mR Radiation Monitor.........................................................................23
06-007 Direct Reading Pocket Dosimeters..................................................................24
Service and Calibration
Service and Calibration Info............................................................................................25
http://www.elso.sk
Fluke Biomedical Europe
Science Park Eindhoven 5110
5692EC Son, The Netherlands
For more information, contact us
In the U.S.A. (800) 850-4608 or
Fax (440) 349-2307
In Europe/M-East/Africa +31 40 267
5435 or
Fax +31 40 267 5436
From other countries +1 (440) 2489300 or
Fax +1 (440) 349-2307
Email: [email protected]
Web access: www.flukebiomedical.
com
Service Center/Repair/Calibration US
Fluke Biomedical
6045 Cochran Road
Cleveland OH 44139-3303
Tel: 440-498-2560
Toll free: 800-850-4608 ext 2564
Email: [email protected]
Service Center/Repair/Calibration
Europe
Fluke Biomedical Europe
Science Park Eindhoven 5110
5692EC Son, The Netherlands
Tel: +31 (40) 267 5435
Fax: +31 (40) 267 5436
Email: [email protected]
Table of Contents
3
riešenia na presné meranie
Fluke Biomedical CarePlans
Priority services to keep you up and running
Instrument CarePlans
lv
er
ze
Biomedical Products
Si
Look for the CarePlans logo in this
catalog for products with available
extended service and support plans.
Fluke Biomedical’s CarePlan packages
offer comprehensive priority service
and support to help you get the most
out of your test equipment investments. Our CarePlan members enjoy
priority bench service, extended warranties, value pricing on services, VIP
technical support, expedited return
shipping, productivity consultation
services, educational training, and
more. Take advantage of CarePlan
priority service and support and let
us take care of you.
Br o
n
Biomedical Products
Instrument CarePlan
Choose the best plan for you
Gold
Silver
Bronze
First-on-bench priority service
•
•
•
Reminder notifications 60 and 30 days prior to
expiration of calibration
•
•
•
Discounts on additional service requests
•
•
•
•
•
•
Turn-around time for repair
3-day
3-day
5-day
Turn-around time for calibration
1-day
3-day
5-day
•
•
•
•
•
•
VIP access to technical support hotline
Operational upgrades
Accredited calibration to manufacturer’s specifications
OEM onsite calibration (where available) ensuring
manufacturer’s specifications
One-year extended warranty beyond your original factory warranty. No-cost repair service.
•
1-day turnaround time for calibration
•
•
•
•
No-cost loaner units during extended repair
24x7 web user training
Protocol development to increase productivity
4
CarePlans
Biomedical Products
Instrument CarePlan
Bronze
Biomedical Products
•
http://www.elso.sk
Instrument CarePlan
riešenia na presné meranie
451B
Ion Chamber Survey Meter with Beta Slide
The auto-ranging 451B measures
radiation rate and accumulated dose
from beta, gamma and x-ray radiation sources. The 451B’s site surveying
capabilities make it well suited for a
wide range of end users, including:
police and fire departments, x-ray manufacturers, government agencies, state
inspectors, emergency response and
HAZMAT teams, nuclear medicine labs,
hospital radiation safety officers, and
nuclear power workers.
The ion-chamber detector allows for
a fast response time to radiation from
leakage, scatter beams and pinholes.
Additionally, the low-noise chamber
bias supply provides for fast background
settling time. A sliding beta shield
serves as an equilibrium thickness for
photon measurements and enables beta
discrimination.
The digital display features an analog
bar graph, 2.5 digit digital readout, low
battery and freeze (“peak hold”) mode
indicators, and an automatic backlight
function. User controls consist of an
ON/OFF button and a MODE button. The
case is constructed of lightweight, highstrength materials and is sealed against
moisture. The RS-232 interface can be
connected directly to a computer for use
with the Excel add-in for Windows®
(451EXL), enhancing the functionality of
the instrument. This software allows for
data retrieval, user parameter selection
and provides a virtual instrument display with audible (requires sound card)
and visual alarm indication.
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
n
Key features
•High sensitivity measurement
of rate and dose simultaneously, with the capability to
record peak rate
•Auto-ranging and auto-zeroing
•RS-232 communications interface with optional Windowsbased Excel add-in for data
logging
•Ergonomic, anti-fatigue handle
with replaceable grip, wrist
strap and tripod mount
•Programmable flashing LCD
display and audible alarm
•Easily-accessible battery door
(operated by two 9-volt alkaline batteries) on the outside of
the bottom case
•Available with dose equivalent
energy response (SI units)
•Shoulder strap and handle
which can be easily decontaminated (Nuclear Power plant
specific unit)
Typical energy dependence
451B typical energy dependence
1.2
1.1
1
Indicated/Actual
0.9
Side
Slide - Closed
0.8
Slide - Open
0.7
0.6
0.5
0.4
0.3
0.2
10
100
Effective (keV)
1000
http://www.elso.sk
10000
Ion Chamber Survey Meters
5
riešenia na presné meranie
451B
Ion Chamber Survey Meter with Beta Slide
Optional accessories
Specifications
Radiation detected
Beta above 100 keV, and Gamma above 7 keV
Operating ranges
0 to 5 mR/h or 0 to 50 µSv/h
0 to 50 mR/h or 0 to 500 µSv/h
0 to 500 mR/h or 0 to 5 mSv/h
0 to 5 R/h or 0 to 50 mSv/h
0 to 50 R/h or 0 to 500 mSv/h
Accuracy
Within 10 % of reading between 10 % and 100 % of full
scale indication on any range, exclusive of energy response.
Calibration source is 137Cs.
451EXL 451 Assistant for Excel,
includes RS-232 interface cable
190HPS Single Unit Carrying Case
450UCS Check Source, 238Uranium,
0.064 µCi, impregnated 2 x 2 in yellow
card
62-103 Check Source, 137Cs, 10 μCi.
Flat disc, 1 inch diameter
Due to recent international airline shipping
policies/restrictions, radioactive “Check
Source” will not be shipped with the main
unit outside US.
Detector
Chamber
349 cc volume air ionization
Chamber wall
246 mg/cm2 thick phenolic
Chamber window
6.6 mg/cm2 mylar, protected by steel mesh, 46 cm 2 detection
area
Beta slide
440 mg/cm2
451B-DE-SI
In order to achieve energy response consistent with
measurements of H*(10) as required by ICR4-47, aluminum
has been added to the back wall, 38 % of the side wall area,
and to the beta slide. With the Beta Shield open, the 451B can
measure skin dose at H*(0.07), and Deep Dose H*(10) with Beta
Shield closed.
Controls
ON/OFF and MODE
Automatic features
Auto-zeroing, auto-ranging, and auto-backlight
Response time
Range
Response
0 to 5 mR/h (0 to 50 µSv/h)
8s
0 to 50 mR/h (0 to 500 µSv/h)
2.5 s
0 to 500 mR/h (0 to 5 mSv/h)
2s
0 to 5 R/h (0 to 50 mSv/h)
2s
0 to 50 R/h (0 to 500 mSv/h)
2s
Display LCD analog/digital with backlight
Analog
100 element bar graph 6.4 cm long. Bar graph is divided into 5
major segments, each labeled with the appropriate value for the
range of the instrument.
Digital
2.5 digit display is followed by a significant zero digit
depending on the operating range of the instrument. The units
of measurement are indicated on the display at all times. Digits
are 6.4 mm (0.25 in) high. Low battery and freeze indicators are
also provided on the display.
Modes
Integrate mode
Operates continuously 30 seconds after the instrument has
been turned on. Integration is performed even if the instrument
is displaying in mR/h or R/h.
Freeze mode
Will place a tick mark on the bar graph display to hold on
the peak displayed value. The unit will continue to read and
display current radiation values.
Environmental
6
Power requirements
Two 9 V alkaline, 200 hours operation
Warm-up time
One minute
Temperature range
-20 °C to 70 °C (-4 °F to 158 °F)
Relative humidity
0 % to 100 %, @ 60 °C
Geotropism
Less than 1 %
Dimensions (WxDxH)
10 cm x 20 cm x 15 cm (4 in x 8 in x 6 in)
Weight
1.11 kg (2.5 lb)
Ion Chamber Survey Meters
http://www.elso.sk
Ordering information
451B-RYR Ion Chamber Survey Meter
with Beta Slide and standard chamber
451B-DE-SI-RYR Ion Chamber Survey
Meter with Beta Slide and dose
equivalent chamber
riešenia na presné meranie
451P
Pressurized µR Ion Chamber Survey Meter
The auto-ranging 451P features
a pressurized ion chamber, providing enhanced sensitivity (µR
resolution) and improved energy
response to measure radiation
rate and dose from x-ray and
gamma sources. Originally
designed to measure leakage and
scatter around diagnostic x-ray
and radiation therapy suites, the
451P’s site surveying capabilities
make it well-suited for a wide
range of end users, including:
x-ray manufacturers, government agencies, state inspectors,
biomedical technicians, and
maintenance technicians for airport baggage scanners.
The ion chamber detector allows for a fast response time to radiation from
leakage, scatter beams and pinholes. Additionally, the low noise chamber
bias supply provides for fast background settling time.
The digital display features an analog bar graph, 2.5 digit digital readout,
low battery and freeze (“peak hold”) mode indicators, and an automatic
backlight function. User controls consist of an ON/OFF button and a MODE
button. The case is constructed of lightweight, high strength materials
and is sealed against moisture. The RS-232 interface can be connected
directly to a computer for use with the Excel add-in for Windows (451EXL),
enhancing the functionality of the instrument. This software allows for data
retrieval, user-parameter selection and provides a virtual instrument display
with audible (requires sound card) and visual alarm indication.
Key features
•High sensitivity µR measurements of rate and dose
simultaneously, with the capability to record peak rate
•Ergonomic, anti-fatigue handle
with replaceable grip, wrist
strap and tripod mount
•Easily-accessible battery door
(operated by two 9-volt alkaline batteries) on the outside of
the bottom case
•RS-232 communications
interface with optional
Windows-based Excel add-in
for data logging
•Available with dose equivalent
energy response (SI units)
•Shoulder strap and handle
which can be easily decontaminated (Nuclear Power plant
specific unit)
Typical energy dependence
Nitrogen gamma rays are 110 % to 120 % of indicated readings as determined at the University of Lowell.
16
451P typical energy dependence
1.2
1.1
1
Indicated/Actual
0.9
Side
0.8
Face
0.7
Front
0.6
0.5
0.4
0.3
0.2
10
100
Effective (keV)
1000
http://www.elso.sk
10000
Ion Chamber Survey Meters
7
451P
riešenia na presné meranie
Pressurized µR Ion Chamber Survey Meter
Optional accessories
Specifications
Radiation detected
Operating ranges
Accuracy
Beta above 1 MeV, Gamma and x-rays above 25 keV
0 to 500 µR/h or 0 to 5 µSv/h
0 to 5 mR/h or 0 to 50 µSv/h
0 to 50 mR/h or 0 to 500 µSv/h
0 to 500 mR/h or 0 to 5 mSv/h
0 to 5 R/h or 0 to 50 mSv/h
Within 10 % of reading between 10 % and 100 % of full
scale indication on any range, exclusive of energy response.
Calibration source is 137Cs
Detector
Chamber
230 cc volume pressurized air ionization chamber to 8
atmospheres or 125 psi
Controls
ON/OFF and MODE
Automatic features
Auto-zeroing, auto-ranging, and auto-backlight
Step increase, background Time to reach 90 % of final
Response time
to
value
Analog response time from
10 % to 90 % of reading for
400 μR/h
4.8 s
a full scale step increase is
4 mR/h
3.3 s
dependent on operating range.
10 mR/h
4.3 s
Response time for a step
increase in radiation exposure 40 mR/h
4.5 s
rate from background:
100 mR/h
2.7 s
1 R/h
2s
4 R/h
2.7 s
10 % to 90 %
This table shows time measured Range
from 10 % to 90 % of final value 0 to 500 μR/h (5 μSv/h)
5s
for a step increase or decrease
0 to 5 mR/h (50 μSv/h)
2s
in exposure rate such that a
0 to 50 mR/h (500 μSv/h)
1.8 s
range change does not occur.
These values are the response
0 to 500 mR/h (5 mSv/h)
1.8 s
times for the various ranges:
0 to 5 R/h (50 mSv/h)
1.8 s
Analog/Digital display LCD with backlight
Analog
100 element bar graph 6.4 cm (2.5 in) long. Bar graph is
divided into five major segments, each labeled with the
appropriate value for the range of the instrument.
Digital
2.5 digit display is followed by a significant zero digit
depending on the operating range of the instrument. The
units of measurement are indicated on the display at all
times. Digits are 0.25 inches (6.4 mm) high. Low battery
and freeze indicators are also provided on the display.
Modes
Integrate mode
Operates continuously 30 seconds after the instrument
has been turned on. Integration is performed even if the
instrument is displaying in mR/h or R/h.
Freeze mode
Will place a tick mark on the bar graph display to hold on
the peak displayed value. The unit will continue to read and
display current radiation values.
Environmental
Power requirements
Two 9 V alkaline, 200 hours operation
Warm-up time
Less than two minutes for initial operation when the
instrument is in equilibrium with ambient temperature.
Temperature range
-20 °C to 50 °C (-4 °F to 122 °F)
Relative humidity
0 to 100 %
Geotropism
Negligible
Dimensions (WxDxH)
10 cm x 20 cm x 15 cm (4 in x 8 in x 6 in)
Weight
1.07 kg (2.4 lb)
8
Ion Chamber Survey Meters
http://www.elso.sk
451EXL 451 Assistant for Excel,
includes RS-232 interface cable
190HPS Single Unit Carrying Case
62-103 Check Source, 137Cs,
10 µCi. Flat disc, 1 inch diameter
Due to recent international airline shipping
policies/restrictions, radioactive “Check
Source” will not be shipped with the main
unit outside US.
Ordering information
451P-RYR Pressurized µR Ion Chamber
Survey Meter with standard chamber
451P-DE-SI-RYR Pressurized µR Ion
Chamber Survey Meter with dose
equivalent chamber
Note: Due to the pressurized ion chamber,
the 451P is considered U.S. Department of
Transportation (DOT) “Dangerous Goods”
and must be shipped via IAW DOT special
permit DOT-SP 13187.
451EXL
riešenia na presné meranie
Assistant for Excel
The 451EXL provides
remote control for many
of the 451B and 451P
functions via a Microsoft®
Excel-based user interface,
including real-time data
logging with user-defined
alarm parameters, upload
of the internal data log into
Excel worksheet, real-time
virtual instrument display,
and accumulated dose
measurement over a userdefined integration period.
This information management software is ideal for the facility Radiation
Safety Officer or anyone responsible for maintaining a permanent record of
spills and accidents for adherence to state and NRC requirements.
The 451EXL’s data logging function automatically records real-time
measured data into an Excel worksheet. The 451 Assistant provides userconfigurable audible and visual alarms for the real-time-logged data,
including the color coding of each data entry for quick identification for
radiation levels and alarm acknowledgment status. This 451EXL information management software program is ideal for the facility radiation safety
officer or anyone responsible for maintaining a permanent record of spills
and accidents for adherence to state and NRC requirements.
Key features
•Real time data logging and
uploading of 451 internal data
log into protected Excel worksheet
•Virtual instrument display with
user-defined audible and visual
alarm indication
•Compatible with Windows®
2000 and above, and Excel 97,
2000
•Package includes manual,
diskette set, and 25 ft RS-232
cable, Model 1020039000
System requirements
•Windows 2000 and above
•Microsoft Excel 97 or 2000
•One serial port (COM1 through
COM4)
Ordering information
451EXL 451 Assistant for Excel
http://www.elso.sk
Ion Chamber Survey Meters
9
riešenia na presné meranie
440RF/D
Low Energy RF Shielded Survey Meter
The 440RF/D is a highly sensitive, low energy, RF
shielded survey meter suited for fast, accurate measurements of background and other low radiation
levels. In particular, the 440RF/D is used to measure
radiation exposure in the color television industry
(cathode-ray tube leakage), radar and transmission
towers where RF may be present, and surveying
applications in high RF fields.
Approved by the Electronic Industries Alliance,
the 440RF/D is designed to meet the radiation
sensitivity and measurement requirements for television receivers set forth by the US Department of
Health and Human Services. Entitled “Performance
Standard for Televisions Receivers” (21 CFR
1020.10), this standard requires that “radiation
exposure rates produced by a television receiver
shall not exceed 0.5 milliroentgens per hour at a
distance of five centimeters from any point on the
external surface of the receiver.”
440RF/D Low Energy RF Shielded
Survey Meter
Radiation detected
RF response
Accuracy
Beta above 150 keV; gamma and x-ray above 12 keV
No response in RF fields up to 10 mW/cm2
Within 10 % of reading between 10 % and 100 % of full scale
indication on any range, exclusive of energy response. Calibration at
21 keV x-ray (27.5 KVCP, 0.9 mmA/HVL).
Geotropism
Within 2 % of full scale in any orientation
Temperature range
20 °C to 40 °C (68 °F to 104 °F)
Relative humidity
0 to 95 %, non-condensing
Pressure
Pressure transducer and temperature sensor automatically apply standard
dependence
air density correction factors from 70 to 106 kPa to the unsealed ion
chamber
Initial stabilization
Approximately 30 seconds
Detector
Internal ionization chamber 3.56 cm diameter by 5.87 cm long, cross
sectional area 10 cm2 volume, with 1.5 mg/cm2 aluminized mylar
window and an external magnesium window 13 mg/cm2 thick. Center
of ion chamber volume is 5 cm from the plane determined by the tips of
three plastic bumpers.
Display
9.5 cm (3.7 in) meter scale, marked 0 to 3 and 0 to 10
Power requirements Five 9 V batteries; 200 hours operation. Three in parallel
configuration for electronic supplies and 2 in series configuration
for—18 V chamber bias.
Controls
Single rotary switch and spring-loaded check source switch
Zero adjust
Auto-zeroing
Check source
Built-in operational uranium check source
Housing material
All metal, splash-proof
Dimensions (WxDxH) 12.7 cm x 20.3 cm x 27.6 cm (5 in x 8 in x 10.8 in)
Weight
3.2 kg (6.8 lb)
Shipping vol/wt
0.071 m3 (2.5 cu ft) 6.05 kg (13.3 lb)
1.2
15 kVcp
Correction Factor
(multiply reading by)
0.8
137 Cs
27.5 kVcp
42.5 kVcp
250 kVcp
50 kVcp
60 Co
200 kVcp
0.6
100 kVcp
150 kVcp
with added equilibrium wall
material in front of window
0.4
0.2
100
10
•Meets US Dept. HHS radiation
survey requirements for Television Receiver and Cabinet
X-ray Systems requirements
(21 CFR 1020.10 and 21 CFR
1020.40, respectively)
•Insensitive to 10 mW/cm2 RF
fields
•Resolves 0.02 mR/h from 15 kV
x-rays
•Measures low energy radiation
exposure down to 12 keV
•Auto-zeroing
•Batteries accessible from outside instrument
Ordering information
Specifications
1.0
Key features
Ion Chamber Survey Meters
1000
Typical energy
dependence
X-ray and gamma
ray: Within 10 % from
12.5 keV to 42 keV.
Maximum response
peak of +40 % at
100 keV. Within
10 % at 137Cs and
60
Co with added
equilibrium wall.
http://www.elso.sk
Due to recent international airline shipping
policies/restrictions, radioactive “Check
Source” will not be shipped with the main
unit outside US.
Operating ranges
440RF/D exposure rate in five
overlapping ranges: 0 to 1, 0 to 3, 0 to 10,
0 to 30, and 0 to 100 mR/h
440RF/D-SI dose equivalent rate in five
overlapping ranges: 0 to 10, 0 to 30, 0 to
100, 0 to 300, and 0 to 1000 µSv/h
Response time 90 % of final
indication in:
Range
Response
0 to 1 mR/h
7 sec
(0 to 10 μSv/h)
0 to 3 mR/h
7 sec
(0 to 30 μSv/h)
0 to 10 mR/h
5 sec
(0 to 100 μSv/h)
0 to 30 mR/h
5 sec
(0 to 300 μSv/h)
0 to 100 mR/h
5 sec
(0 to 1000 μSv/h)
ASM-990 Series
riešenia na presné meranie
Advanced Survey Meter
The ASM-990 Series Advanced
Survey Meter can detect alpha,
beta, gamma, or x-ray radiation
within an operating range of 1 µR/
hr to 1 R/hr (1 to 5,000,000 CPM),
depending on the selected probe
(Geiger-Mueller, neutron, proportional counter, scintillation). With
the proper probe combination, this
meter can be used as a general
survey meter, an area monitor, a
wipe-test counter, and a contamination monitor.
Designed to meet the high- technology requirements of health
physics, medical physics, and
nondestructive testing applications,
the ASM-990 Series is well-suited for a wide range of end users, including:
radiation safety officers, nuclear medicine laboratories, diagnostic x-ray and
hospital emergency-room technicians, environmental-health physicists, and
emergency responders.
The unit, with purchased probe, is shipped calibrated and ready-to-use
and includes a MHV connector to ensure compatibility with all Fluke
Biomedical probes. The 992 includes a fully-calibrated internal energycompensated 1 R/hr GM detector. The 993 features a fully-calibrated
internal pancake detector as well as an internal energy-compensated
1 R/hr GM detector.
Key features
•Simultaneous auto-scaling
measurement of rate and dose
with the capability to record
peak rate
•Up to five different probes can
be calibrated with one unit
•Data-logging survey mode feature allows user to store up to
five separate survey sequences
•Saved data can be uploaded to
a PC via included Infrared Data
(IrDA) transmitter
•Easy-to-use multifunction
keypad for intuitive menu navigation
•Backlit analog/digital LCD
display with full-range audio
output capability
•Barcode scanner (optional)
•Auto power-down feature
extends battery life
Specifications
ASM-990 and ASM-992
Operating modes
•Rate
• Scaler (dual option: “based on
• Integrate measurement” or “based on time”)
• Timed Peak Hold
• Data Logging
Operating rate ranges
(dependent on selected
probe)
µR/hr
mR/hr
R/hr
µrem/hr
mrem/hr
rem/hr
µSv/hr
CPM
mSv/hr
CPS
Sv/hr
DPM 99mTc
DPS 131I
Bq 125I
kBq 123I
MBq 201Tl
µCi 67Ga
mCi 18F
Ci 57Co
µR
mR
R
µrem
mrem
rem
Complementary units in the
integrate mode with the
integrated time value in
seconds
µSv
mSv
Sv
C (counts)
kC
MC
D (distintigrations)
kD 99mTc
MC 131I
Accuracy (dependent on
selected probe)
Within 10 % of reading between 10 % to 100 % of full scale indication on any range, exclusive of typical
energy dependence
Detector
Accepts GM detectors and scintillation probes operating at high voltages between 500 volts and 1300 volts
Temperature range
-10 °C to 50 °C (14 °F to 122 °F)
Relative humidity
0 % to 95 %, non-condensing
Warm up time
5 second diagnostic check
Check source
Natural uranium, mounted on the case
Power requirements
Two “D” cells, 150 hours operation, automatically indicates when battery is low
Housing material
Proprietary polycarbonate, splash-proof case
Display
Liquid crystal display, 5.6 cm x 5.6 cm (2.2 in x 2.2 in)
http://www.elso.sk
Survey Meters and Probes
11
ASM-990 Series
riešenia na presné meranie
Advanced Survey Meter
Data logging screens
Data logging modes
The ASM-990 Series Log Data feature can easily be accessed via the setup
sub-menu. The unit can log/save a maximum of 500 data points in any of
three separate modes (manual and survey modes can utilize the optional
barcode scanner.)
Manual: Individual rate data points can be saved by pressing the Start/
Stop/Rst/Save button.
Timed: Data points automatically saved at user-selectable time intervals in
the range of 1 second to 255 seconds.
Survey: Programmed sequences accessed via the menu system. Pressing the
Start/Stop/Rst/Save button saves the current reading and displays the next
survey location.
Programming of survey sequences, as well as retrieval of logged data, is
accomplished via the built-in IrDA port.
Label names up to 20 characters can be programmed into the unit to
identify the individual survey locations.
Probe connector: The unit is available with a MHV connector. The unit can
be used with multiple probes (5 total) by selecting the appropriate probe
from the main menu. All calibration data for each probe is stored in the
unit’s EEPROM.
Specifications
Internal Energy Compensated GM Tube
Range
0.1 mR/hr to 1 R/hr
Radiation detected
Gamma above 60 keV
Accuracy
± 10 % of reading between 10 % and 100 % of full scale on any
range, exclusive of energy dependence
Weight (without probe)
ASM 990, 992: 0.95 kg (2.1 lb) ASM 993: 1.09 kg (2.4 lb)
Dimensions (WxDxH)
10.47 cm x 27.71 cm x 6.35 cm (4.125 in x 10.91 in x 2.5 in)
Typical energy dependence
Internal energy compensated 1 R GM detector
1.4000
1.2000
Indicated/Actual
1.0000
0.8000
0.6000
0.4000
0.2000
0.0000
10
100
1000
Energy (keV)
12
Survey Meters and Probes
http://www.elso.sk
10000
ASM-990 Series
riešenia na presné meranie
Advanced Survey Meter
Optional accessories
Specifications
990-IR-USB USB Port IrDA Adapter
990CC Carrying Case
Internal Pancake GM Tube
Radiation detected
Alpha above 3.5 MeV, beta above 35 keV and gamma above
6 keV
Range
Background to 80 mR/hr
Window
15 cm2 (1.75 in Ø) mica, 1.4 mg/cm2 to 2.0 mg/cm2
Typical background
30 CPM
Protective screen
Stainless steel, hexagonal pattern providing 86 % open area
Accuracy
± 10 % of reading between 10 % and 100 % of full scale on any
range, exclusive of energy dependence (protective cover open)
Efficiency
The internal pancake
detector efficiency is
shown below. In a recent
performance check, the
numbers shown represent
typical results obtained:
Note: The efficiency
formula used to calculate
the %Efficiency is:
Eff. % = (CPM x 100)/DPM
Isotope
14
%Efficiency
C
4%
Tc
12 %
99
Cs
19 %
90
Sr
51 %
36
Cl
19 %
Am
9%
I
1%
Pu
14 %
137
241
129
239
Note: The ASM-990 Series, with the customer-selected probe is calibrated to NIST
standards. The ASM-990 series with GM
probe standard calibration is in R, Sv, and
rems. Scintillation detectors are calibrated
in counts. Radionuclide-specific efficiency
calibrations are available upon request. For
probe selection and calibration services,
see next page.
Due to recent international airline shipping
policies/restrictions, radioactive “Check
Source” will not be shipped with the main
unit outside US.
Ordering information
990 Advanced Survey Meter
990BC Advanced Survey Meter with
barcode reader
992 Advanced Survey Meter with an
internal 1 R GM detector
992BC Advanced Survey Meter with an
internal 1 R GM detector and barcode
reader
993 Advanced Survey Meter with an
internal 1 R GM detector and internal
pancake detector
993BC Advanced Survey Meter with an
internal 1 R GM detector, internal pancake detector, and barcode reader
Typical energy dependence
Internal pancake detector
5
4.5
4
Indicated/Actual
3.5
3
2.5
2
1.5
1
0.5
0
100
10
1000
125
137
Cs
10000
60
Co
Energy (keV)
Model comparison
Advanced
survey meter
•
Barcode
reader
990BC
•
•
992
•
992BC
•
993
•
993BC
•
Model
990
Internal energy compensated Internal pancake
1 R/hr GM detector
detector
•
•
•
•
•
•
•
•
http://www.elso.sk
Survey Meters and Probes
13
riešenia na presné meranie
489-110D
GM Pancake Probe
Key features
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
n
Designed for use in conjunction with the ASM-990 Series and other standard GM survey meters, the 489-110D can detect alpha, beta, and gamma
radiation. It is configured for operating convenience in table-top and floor
surveys as well as surveys of personnel and equipment. Prime applications
for this probe include nuclear medicine counter tops and frisker stations,
leakage detection for low energy diagnostic x-ray machines, geological and
environmental surveys or any place where there exists the suspicion that
some form of radiation is present, especially emergency response teams.
For storage and carrying ease, the probe fits into the standard handle clip
on a survey meter.
The GM probe comes in two configurations: 489-110D with an ABS
plastic housing, MHV connector, and foam grip, or 489-110E with a BNC
connector. This selection of connectors provides the ability to attach the
GM probe to most GM survey meters on the market. Replacement foam grip
handles are available: 489-130-44. This same probe design is available in
a rugged metal housing as 489-110C.
Specifications
Detector
Halogen-quenched “Pancake” GM tube
Radiation detected
Alpha above 3.5 MeV, beta above 35 keV and gamma above 6 keV
Operating voltage
900 V; compatible with all GM survey meters
Window
15 cm2 (1.75 in Ø) mica, 1.4 to 2 mg/cm 2 thick
Typical background
30 CPM
Sensitivity
3500 CPM/mR/hr
Protective screen
Stainless steel, hexagonal pattern providing 86 % open area
Housing material
ABS plastic housing and foam grip handle
Cable
Shielded cord; approximately 4.5 ft long MHV coaxial connector or
BNC connector
Dimensions
Detector housing (WxDxH): 6.36 cm x 2.2 cm x 10.8 cm
(2.50 in x 0.875 in x 4.25 in)
Handle (excluding connector): 2.5 cm Ø x 16.5 cm dia.
(1 in Ø x 6.25 in dia.)
Weight (pancake
probe only)
0.28 kg (0.625 lb)
4.5
4
Indicated/Actual
3.5
3
2.5
2
1.5
1
0.5
0
100
1000
137
Cs
Effective (keV)
14
Survey Meters and Probes
489-130-44 Foam Grip Handle
Ordering information
489-110D GM Pancake Probe with ABS
plastic housing, MHV connector, and
foam grip handle
489-110E GM Pancake Probe with ABS
plastic housing, BNC connector, and
foam grip handle
489-110C GM Pancake Probe with
metal housing, MHV connector, and
foam grip handle
489-110D GM Pancake Probe efficiency is shown below. In a recent
performance check, the numbers
shown represent typical results
obtained:
Isotope
14
C
99
Tc
137
Cs
90
Sr
36
Cl
241
Am
129
I
239
Pu
%Efficiency
4
12
19
51
19
9
1
14
Note: The efficiency formula used to
calculate the % Efficiency is: Eff. % =
(CPM x 100)/DPM
GM Pancake Probe typical energy dependence
5
125
Replacement parts
Efficiency
Typical energy dependence
10
•All purpose GM Pancake Probe
detects alpha, beta, gamma,
and x-ray radiations
•High detection efficiency
•Lightweight, ergonomic design
•Detachable probe cable
•BNC or MHV connector
•Easy to decontaminate
10000
60
Co
http://www.elso.sk
riešenia na presné meranie
489-XXX, 90-12, 425-XXX
Geiger-Mueller and Scintillation Probe Selection Guide
489-110D GM Pancake Probe
• Alpha above 3.5 MeV
• Beta above 35 keV
• Gamma and x-ray > 6 keV
• To 80 mR/hr (800 µSv/hr)
489-50 Gamma Scintillation Probe
• Gamma and x-ray > 60 keV
• 1 in x 1 in, 1.5 in x 1.5 in and 2 in x 2 in NaI (Tl)
detectors available
489-200 Scintillation Pancake Probe
• Beta above 100 keV
• Gamma and x-ray > 25 keV
• NaI (Tl) rectangular
90-12 Energy Compensated GM Probe
• Beta above 200 keV
• Gamma and x-ray > 12 keV
• Up to 1 R/hr (10 mSv/hr)
489-35 Thin End Window GM Probe
• Alpha above 4 MeV
• Beta above 70 keV
• Gamma and x-ray > 6 keV
• Up to 80 mR/hr (800 µSv/hr)
489-60 Alpha Scintillation Probe
• Alpha above 4 MeV
• 1.5 in Ø ZnS (Ag)
425-110 Low Energy Gamma Scintillation Probe
• Gamma and x-ray > 10 keV
• NaI (Tl) 1 mm thick
491-40 Utility 1 R/hr GM Probe
• Beta above 200 keV
• Gamma and x-ray > 12 keV
• Up to 1 R/hr (10 mSv/hr)
Key features
•Rugged and reliable designs
•GM probes are available in
pancake style, energy compensated and with beta
discrimination
•Scintillators are test selected
and optically coupled to photomultiplier tubes
GM probes for qualitative
radiation detection—the GeigerMueller (GM) detectors fulfill a
wide variety of radiation measurement needs for alpha, beta,
gamma and x-ray sources. Some
probes have are provided with a
360° shield to permit discrimination between penetrating and
non-penetrating radiation.
The GM detectors have a
field-proven design to ensure
dependable performance, reliability and ruggedness. Standard
MHV type connectors readily
allow interchange of all detector probes. The life expectancy
of the counters ranges from 108
total counts to unlimited life
depending on the type of quench
gas utilized. Enhanced sensitivity to low-level alpha, beta,
gamma and x-ray radiation is
achieved when using the unique
498-110D Pancake GM Probe.
The following probe selection
guide lists various probes and
suggested applications. Applications include nuclear medicine
counter-top surveys, leakage
detection from diagnostic x-ray
and linear accelerators, geological surveys, scrap metal yards
and unknown wells.
425-200 Alpha/Beta Scintillation Probe
• Alpha above 350 keV
• Beta above 14 keV
• Plastic scintillator
Instrument CarePlans
Si
http://www.elso.sk
er
ze
Biomedical Products
lv
Br o
n
Survey Meters and Probes
15
riešenia na presné meranie
489-XXX, 90-12, 425-XXX
Geiger-Mueller and Scintillation Probe Selection Guide
Scintillation probes for quantitative radiation assessment (counts/
minute) – The scintillation detectors are optically coupled to photomultiplier tubes, which are then both magnetically shielded with mu-metal and
specially shock-mounted to provide trouble-free performance. The entire
detector, crystal and photomultiplier, are secured in a sturdy cylindrical
aluminum housing. Where appropriate, a thin window has been utilized to
provide alpha or low energy gamma response.
Applications outlined in this guide include nuclear medicine labs,
HAZMAT spills, radiation safety office surveys, industrial hygiene, industrial
x-ray manufacturing, and geological surveys.
Specifications
Scintillation probes
Model
489-50
489-55
489-120
489-60
425-110
425-200
489-200
Type
NaI (Tl) Sodium
Iodide 1 x 1, scintillator optically
coupled to PMT
NaI (Tl) Sodium
Iodide 1.5 x 1.5,
scintillator optically coupled to
PMT
NaI (Tl) Sodium
Iodide 2 x 2,
scintillator optically coupled to
PMT
ZnS (Ag)
Alpha,
scintillator
optically coupled
to PMT
NaI (Tl)
Thin Scintillator
for Low Energy
Gamma,
scintillator optically coupled to
PMT
NE 102A Plastic
Scintillator
Flashlight Probe,
scintillator optically coupled to
PMT
NaI (Tl)
Pancake,
scintillator
optically coupled
to PMT
Radiation detected
Gamma and x-ray
above 60 keV
Gamma and x-ray
above 60 keV
Gamma and x-ray
above 60 keV
Alpha above
4 MeV
Gamma and x-ray
above 10 keV
Alpha above
350 keV, beta
above 14 keV
Gamma and x-ray
above 25 keV,
beta above
100 keV
Applications
•
•
•
•
•
• Nuclear
medicine seed
finder
• Alpha detection
Uranium,
Plutonium
• HAZMAT
• RSO
• Primary probe
for nuclear
medicine
• Low energy
x-ray
manufacturing
• Industrial
hygiene
• Alpha, beta
counting of
filter paper
• HAZMAT
spills
• Nuclear
medicine
missing sources
• Beta, gamma
frisker for
nuclear
medicine is 10
times more
sensitive than
GM probe
• Environmental
surveys
Typical background
(CPM)
1750
5000
6000
20
200
38
3000
Nominal
sensitivity
160,000 CPM/
mR/hr 137Cs
350,000 CPM/
mR/hr 137Cs
700,000 CPM/
mR/hr 137Cs
300,000 CPM/µCi
241
Am
3,000,000 CPM/
µCi 129l
0.0012 CPM/DPM/
100 cm 2 63Ni
650 CPM/µR/hr
137
Cs
Wall material
0.04 in Al,
1 mm thick
0.04 in Al,
1 mm thick
0.04 in Al,
1 mm thick
0.04 in Al,
1 mm thick
0.04 in Al,
1 mm thick
0.04 in Al,
1 mm thick
0.04 in Al,
1 mm thick
Window
108 mg/cm 2
Al
108 mg/cm 2
Al
108 mg/cm 2
Al
3 mg/cm 2
Al Mylar
8 mg/cm 2
Al
0.25 mg/cm 2
Plastic
130 mg/cm 2
Al
Sensitive area
5 cm 2
11.4 cm 2
20 cm 2
11.4 cm 2
5 cm 2
20.3 cm 2
59.2 cm 2
Crystal dim.
2.5 cm x 2.5 cm
(1 in x 1 in)
3.8 cm x 3.8 cm
(1.5 in x 1.5 in)
5.1 cm x 5.1 cm
(2 in x 2 in)
3.8 cm Ø
(1.5 in Ø)
2.5 cm Ø
(1 in Ø)
5.1 cm Ø
(2 in Ø)
5.1 cm x 5.1 cm x
1.3 cm (2 in x 2 in
x 0.5 in)
Probe dia.
5.1 cm (2 in)
5.1 cm (2 in)
5.7 cm (2.25 in)
5.1 cm (2 in)
5.1 cm (2 in)
6.7 cm (2.625 in)
5.7 cm x 1.8 cm
(2.25 in x 0.69 in)
Probe length
22.2 cm (8.75 in)
23.2 cm (9.125 in)
24.5 cm (9.625 in) 18.4 cm (7.25 in)
20.6 cm (8.125 in)
20.3 cm (8 in)
28 cm (11 in)
Cable length
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
Sensitivity to
I
Sensitivity to 90Sr,
99
Tc, 137Cs, 14C
90
Sr 22 %
Cl 8 %
241
Am 8 %
133
Ba 34 %
90
90
36
99
137
Nuclear medicine
Industrial hygiene
Industrial x-ray manufacturing
Geological surveys
Radiation safety office
122 cm (48 in)
Operating
voltage
Calibration
900 V
137
Cs 2 pts/scale
to 10 mR/hr
137
Cs 2 pts/scale
to 100 mR/hr
Cs 6 %
57
Co 9 %
133
Ba 6 %
60
Co 2 %
137
137
Cs 2 pts/scale
to 10 mR/hr
Sensitivity to
Am
241
Cal. tolerance
Efficiency
Sensitivity to
Tc
99m
± 10 %
137
Cs 13 %
Cs 26 %
137
Pu 13 %
241
Am 8 %
239
Sr 7 %
Tc 3 %
137
Cs 5 %
14
C1%
Humidity range
0 to 95 %
Operating temp
-40 °C to + 50 °C (-40 °F to +120 °F), maximum temperature increase of 20 °F/hr
Weight (approx.)
16
129
0.68 kg (1.5 lb)
Survey Meters and Probes
0.68 kg (1.5 lb)
0.91 kg (2.0 lb)
0.68 kg (1.5 lb)
http://www.elso.sk
0.68 kg (1.5 lb)
0.35 kg (0.78 lb)
SR 5 %
Cs 11 %
Ba 34 %
60
Co 16 %
133
0.35 kg (0.78 lb)
riešenia na presné meranie
489-XXX, 90-12, 425-XXX
Geiger-Mueller and Scintillation Probe Selection Guide
Specifications
Geiger-Mueller probes
Model
489-110C/D/E*
90-12
489-35
493-50
491-40
491-30
Type
Pancake alpha,
beta, gamma, and
x-ray with thin
pancake window
Energy compensated beta, gamma,
and x-ray with 360°
linear movement
shield for beta
discrimination
Alpha, beta, gamma,
and x-ray with
0.875 inch thin end
window
Beta, gamma, and
x-ray with sliding
360° metal shield for
beta discrimination
Beta, gamma, and
x-ray with sliding
360° metal shield for
Beta discrimination
Beta, gamma, and
x-ray with sliding
360° metal shield for
beta discrimination
Radiation
detected
Alpha above
3.5 MeV, beta above
35 keV, gamma and
x-ray above 6 keV
Beta above 200 keV
and gamma above
12 keV
Alpha above 4 MeV,
beta above 70 keV,
and gamma and
x-ray above 6 keV
Gamma above
12 keV and beta
above 200 keV
Gamma above
12 keV and beta
above 200 keV
Gamma above
12 keV and beta
above 200 keV
Applications
• All-purpose
sensitive alpha,
beta, and gamma
and x-ray probe
• Nuclear medicine
counter tops
• Detects leakage
from diagnostic
x-ray machines,
especially
mammography
• Geological surveys
• Scrap metal yards
• HAZMAT
• Energy
compensated
to eliminate low
energy over
response
• Convenient size
to fit in small
spaces around
linear
accelerators
• X-ray tube
manufacturers
• Ultra sensitive
alpha, beta,
gamma probe
with directional
focus
• Nuclear medicine
• Emergency
response
• Rugged probe
with beta
discrimination
• Scrap metal yards
• Rugged to drop
down wells
• Nuclear medicine
Typical background
(shielded)
30 CPM
15 CPM
50 CPM
15 CPM
15 CPM
20 CPM
Maximum exposure
rate
80 mR/h
(800 µSv/hr)
1 R/h
(10 mSv/hr)
80 mR/h
(800 µSv/hr)
1 R/h
(10 mSv/hr)
1 R/h
(10 mSv/hr)
100 mR/h
(1 mSv/hr)
Nominal sensitivity to
1 mR/hr of 60Co
3500 CPM
720 CPM
3900 CPM
720 CPM
720 CPM
2200 CPM
Replacement GM tube
part number
P-115
35-166
489-76
35-166
35-166
35-150
Wall material
Stainless steel with
mica window
Stainless steel
Stainless steel with
mica window
Stainless steel
Stainless steel
Stainless steel
Wall thickness
1.5 to 2.0 mg/cm 2
40 to 60 mg/cm 2
1.4 to 2.0 mg/cm 2
40 to 60 mg/cm 2
40 to 60 mg/cm 2
30 to 40 mg/cm 2
• Beta, gamma
probe is more
sensitive than
491-40 or 493-50,
but has max. rate
of 100 mR/hr
Active length
38 mm (1.5 in Ø)
19.1 mm (0.75 in)
102 mm (4 in)
19.1 mm (0.75 in)
19.1 mm (0.75 in)
57.2 mm (2.25 in)
Quenching gas
Neon and halogen
Neon and halogen
Neon and halogen
Neon and halogen
Neon and halogen
Neon and halogen
Diameter of probe
68 mm (2.6875 in)
35 mm (1.375 in)
33.4 mm (1.3125 in)
32 mm (1.25 in)
30 mm (1.1875 in)
30 mm (1.1875 in)
Length of probe
248 mm (9.75 in)
170 mm (6.7 in)
191 mm (7.5 in)
84 mm (3.3125 in)
136 mm (5.375 in)
136 mm (5.375 in)
Cable length
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
122 cm (48 in)
Weight (approx.)
0.45 kg (1.0 lb)
0.26 kg (0.59 lb)
0.45 kg (1.0 lb)
0.45 kg (1.0 lb)
0.45 kg (1.0 lb)
0.45 kg (1.0 lb)
Operating voltage
900 V
900 V
900 V
900 V
900 V
900 V
Humidity range
0 to 95 %
0 to 95 %
0 to 95 %
0 to 95 %
0 to 95 %
0 to 95 %
Operating
temperature range
-56 °C to +85 °C
(-65 °F to +185 °F)
-56 °C to +85 °C
(-65 °F to +185 °F)
-56 °C to +85 °C
(-65 °F to +185 °F)
-56 °C to +85 °C
(-65 °F to +185 °F)
-56 °C to +85 °C
(-65 °F to +185 °F)
-56 °C to +85 °C
(-65 °F to +185 °F)
Pressure range
To 5 psig
To 15 psig
To 5 psig
To 15 psig
To 15 psig
To 15 psig
Ordering information
489-110D GM Pancake Probe
489-50 Gamma Scintillation Probe
489-55 Gamma Scintillation Probe
489-120 Gamma Scintillation Probe
489-200 Scintillation Pancake Probe
90-12 Energy Compensated GM Probe
489-35 Thin End Window GM Probe
http://www.elso.sk
489-60 Alpha Scintillation Probe
425-110 Low Energy Gamma
Scintillation Probe
491-40 Utility 1 R/hr GM Probe
493-50 Utility 1 R/hr GM Probe
491-30 Utility 100 mR/hr GM Probe
425-200 Alpha/Beta Scintillation
Probe
Survey Meters and Probes
17
riešenia na presné meranie
190N
Portable Neutron Survey Meter
The self-contained 190N Portable
Neutron Survey Meter measures
mRem in accordance with the
classical Anderson and Braun
design. The neutron probe can be
attached to either a 190 Survey
Meter or a 190F Frisker for continuous neutron surveys or area
monitoring.
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
n
Key features
•Auto-scaling measurement
of rate and dose (integrate
mode includes dose and time
accumulation)
•True Rem readings recorded
across a wider (lower and
higher) rate range
•Ergonomic, portable design:
adjustable shoulder strap and
rugged handle with padded
grip
•Flexible detector assembly,
190 can be removed for remote
readings
•Available in SI units
Specifications
Readout
Programmable features of a standard 190 Survey Meter. Refer to the 190 data sheet for complete details
Detector assembly, RP-N
The detector assembly is a polyethylene cylinder, 9.5 in L x 8.5 in dia., containing a BF3 proportional counter
and neutron energy compensating materials. It is based upon the standard reliable Anderson and Braun
design for neutron energy response. The handle is padded for ease of gripping. An adjustable shoulder strap
is provided
BF3 operating characteristics
The BF3 proportional counter operates at 1150 V. Active length is 5.08 cm (2 in). Fill gas is enriched BF3, 96
% Boron 10. Gas pressure is 20 cm Hg. Resolving time is 1 microsecond, plateau slope is 2 % per 100 V and
tube life expectancy is greater than 1010 counts
Typical neutron sensitivity
Nominal 2000 counts per mRem
Range
Rate: 0 µRem/h to 75 Rem/h
0 µSv/R to 0.75 Sv/h
0 CPM to 2.5 x 106 CPM
0 CPS to 41,660 CPS
Integrate: 0 µRem to 1000 Rem
0 µSv to 10 Sv
0 to 109 counts
Gamma sensitivity/rejection
No response in 137Cs gamma radiation in fields up to 500 R/h
Accuracy
10 % of theoretical ICRP dose rate
Dimensions
31.75 Ø x 26 cm dia. (12.50 Ø x 10.25 in dia.)
Miscellaneous
Detector assembly cable length: 1.37 m (4.5 ft). An optional 9.14 m (30 ft) cable is available.
Weight
9.52 kg (21 lb) (total 190 + detector assembly)
Directionality
Less than 20 % in three orthogonal directions
Temperature range
190 operating range: ‑10 °C to +40 °C (14 °F to 104 °F)
Detector assembly operating range: -80 °C to +80 °C (-112 °F to 176 °F)
Power requirements
Four 9 V alkaline batteries supplied, 100 hours operation
Calibration
190N is calibrated against a NIST traceable “Tissue Equivalent Proportional Counter” and uses Radium/
Beryllium neutrons at a distance of 100 cm
Typical energy dependence
cps/N/cm2/sec
10E1
190N Sensitivity
Ordering information
ICRP Response
20 CPS/2.5 MREM/HR
190N Portable Neutron Survey Meter
190N-SI Portable Neutron Survey
Meter, SI Unit
10E0
10E-1
10E-2
10E-3
10E-2
10E-1
10E0
10E1
10E2
10E3
10E4
10E5
190N Typical Energy Response
18
Survey Meters and Probes
10E6
10E7
10E8
http://www.elso.sk
riešenia na presné meranie
190F
Area Monitor/Frisker Count Rate Meter
The easy-to-use, auto-ranging 190F is
compatible with GM detectors, neutron probes, proportional counters, and
scintillation probes operating from 300
volts to 1,300 volts. Depending on probe
selection, the 190F detects alpha, beta,
gamma, x-ray or neutron radiation within
an operating range of 1 µR/h to 1 R/h
(1 CPM to 1,000,000 CPM). The unit is
available with either an MHV or a BNC
connector.
Visual indication of selected parameters, as well as measured values, are
displayed on the analog/digital display.
The 190F Area Monitor/Frisker Count
Rate Meter, with purchased probe, is
shipped calibrated and ready-to-use.
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
Key features
•Auto-scaling measurement of
rate and dose simultaneously
•Adjustable Alarm
•Backlit analog/digital LCD
display with bar graph and
operational units
•Interchangeable probe adapter
module
•Data logging
Ordering information
190F Area Monitor/Frisker Count Rate
Meter
Due to recent international airline shipping
policies/restrictions, radioactive “Check
Source” will not be shipped with the main
unit outside US.
n
Specifications
Accuracy
Within 10 % of reading between 10 % to 100 % of full scale
indication on any range, exclusive of energy dependence. Accuracy
is probe dependent.
Detector
Accepts GM detectors, neutron probes, scintillation probes, and
propor-tional counters operating at high voltages between 300 V
and 1300 V.
Adapter module
Contains calibration data and high voltage settings for a specified
probe. The module is available with an MHV or a BNC connector.
Specify the type of connector with order.
Note: Additional adapter modules can be purchased for use with
multiple probes: Specify 190060 for MHV adapter module and
190070 for BNC adapter module. By using multiple replaceable
probe adaptor modules, each module can be assigned to a specific
probe. The module’s EEPROM stores the calibration factors for a
specific probe. When plugged into a 190F Area Monitor and Count
Rate Meter, it automatically sets the high voltage and activates
the calibration data set for the specific probe. By using modules
married to specific probes, the user has the convenience of using
only one 190F with multiple probes for survey work.
Log
Logs 211 data points and sequentially labels data points. (Data
retrieval requires the 190-1A Infrared Communicator). With
the communicator, alphanumerics up to 16 characters can be
programmed into the 190F to name the locations of individual data
points to be collected. The location name is displayed when the
Log button is pressed. Press the Log button again, and the data
point is stored.
Power requirements
9 V dc regulated power converter
Batteries
Three 9 V batteries, 150 hours operation, automatically indicates
when battery is low
Warm up time
15 second diagnostic check
Check source
Natural uranium, mounted on the case
Temperature range
-10 °C to +60 °C (14 °F to 140°F)
Relative humidity
0 to 95 %, non-condensing
Housing material
Molded ABS plastic, splash-proof case. Probe fits into side-mounted
ABS plastic probe holder with Velcro® straps.
Dimensions (WxDxH)
9.2 cm x 23.4 cm x 5 cm (3.75 in x 9.2 in x 2.1 in)
Weight (without probe)
0.70 kg (1.56 lb)
http://www.elso.sk
Operating ranges (dependent
on selected probe)
Toggles and selects rate units:
μR/hr
CPM
μSv/hr
DPM
mR/hr
CPS
mSv/hr
Bq/cm 2
R/hr
μCi/cm2
and the complementary units in
the integrate mode:
μR
CTS
μSv
Bq
mR
D
mSv
μCi
R
with the integrated time value
in seconds
Area Monitors
19
riešenia na presné meranie
05-437
PRIMALERT® 35 Area Radiation Monitor
Instrument CarePlans
Si
lv
er
ze
Biomedical Products
Br o
n
The PRIMALERT 35 Area Radiation Monitor contains an energy-compensated GM detector and has
six range indicators (1, 2, 4, 8, 16, and 32 mR/hr)
that can clearly display an increase or decrease
in radiation levels. The visible and audible alarms
can be set at any of the six levels by a front-panel,
screwdriver-adjustable control. When each preset
radiation level is exceeded, personnel are alerted
by bright flashing red lights (visible over a 180°
field) and a loud intermittent audio signal. The
alarms stop automatically when the radiation level
falls below each of the preset values. This permits
instant radiation-level recognition not readily distinguishable on meter-type instruments.
Fail-safe operation is assured by a light which
continuously indicates background radiation and
provides visual proof that the unit is functioning.
The monitor will not jam or show false readings in high radiation fields. A mounting bracket
and a 110 V ac adapter/power converter are also
included.
Power requirements
105 V to 125 V/60 Hz/8 W
Dimensions (WxHxT)
9 cm x 15 cm x 4 cm (3.5 in x 6 in x 1.5 in)
Weight
0.9 kg (2 lb)
Area Monitors
•Provides continuous visual
indication of radiation levels
and produces audible and/
or visual alarms at any of six
programmable radiation levels
•Assures reliable, continuous
monitoring wherever radioactive materials are present
•Displays the radiation level in
bright color-coded lights
•Optional Primalarm Remote
Alarm, which functions up to
100 feet from monitor
Optional accessories
62-103 Check Source, 137Cs,
10 μCi. Flat disc, 1 in diameter
Ordering information
Specifications
20
Key features
http://www.elso.sk
05-437 Primalert 35 Area Radiation
Monitor
Included accessories
AC adapters, specify with order
14-314 110 V ac 12 V dc 500 mA
(USA, Japan)
14-400 230 V ac 12 V dc 500 mA
(Europe)
14-436 230 V ac 12 V dc 580 mA
(Australia)
riešenia na presné meranie
05-443 and 05-444
PRIMALERT® Digital Area Monitors
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
n
The PRIMALERT Digital Area Monitors
are designed for a wide range of
gamma radiation area monitoring
applications. Two self-contained
configurations are available, each
with an internal energy compensated GM detector (detection range in
parentheses): 05-443 (0.1 mR/h to 1
R/h) and 05-444 (1 mR/h to 4 R/h).
Both models are ac powered with an
internal battery backup, have usersettable low and high alarms, and are available with an
optional remote alarm for added security.
The versatile PRIMALERT Digital Area Monitors can
be used in industrial applications, medical settings, or
wherever there is a need to warn personnel of increasing
radiation levels and/or to limit the accumulated exposure of
personnel to gamma radiation.
Specifications
Indicated use
Radiation area monitoring
Internal GM detector range
05-443: 0.1 mR/hr to 1 R/hr; 05-444: 1 mR/hr to 4 R/hr
Display
4 digit LED display with 2 cm (0.8 in) character height; display
range: 000.0 to 9999
Display units
Can be made to display in µR/hr, mR/hr, R/h, µSv/h, mSv/h,
Sv/h, cpm, cps and others
Linearity
Reading within ± 10 % of true value with detector connected
Response
Typically 3 seconds from 10 % to 90 % of final reading
Status (green light)
Indicates the instrument is functioning properly
Low alarm
Indicated by a yellow light and slow beep (1 per sec) audible
tone (can be set at any point from 0.0 to 9999)
High alarm
Indicated by a red light and fast beep (4 per sec) audible tone
(can be set at any point from 0.0 to 9999)
Detector fail
Red light and audible tone; > 68 dB at 2 ft indicates detector
overload, no count from detector, or instrument failure
Low battery (yellow)
Indicates < 2 hours of battery power remaining
Calibration controls
Accessible from front of instrument (protective cover provided)
High voltage
Adjustable from 200 V to 2500 V
Threshold
Adjustable from 2 mV to 100 mV
Dead time
Adjustable to compensate for dead time of the detector and
electronics (can be read on the display)
Overload
Senses detector saturation (indicated by display reading “-OL”)
Overrange
Indicates the radiation field being measured has exceeded the
counting range of the instrument (indicated by display reading
“----”)
Data output
9 pin connector providing 5 decade log output, RS-232 output,
signal ground connection, FAIL and Alarm signals (current
sink), and direct connection to battery and ground
Power requirements
95 V ac to 135 V ac (178 V ac to 240 V ac available), 50 Hz to
60 Hz single phase (< 100 mA), 6 V sealed lead acid
rechargeable battery (built-in)
Battery life
Typically 48 hours in non-alarm condition, 12 hours in alarm
condition
Battery charger
Battery is continuously trickle charged when instrument is
connected to line power and turned on
Housing material
Aluminum housing with white polyurethane enamel paint
Temperature range
-20 °C to 50 °C (-4 °F to 122 °F). May be certified for operation
from -40 °C to 65 °C (-40 °F to 150 °F).
Dimensions (WxDxH)
24.6 cm x 6.4 cm x 18.7 cm (9.7 in x 2.5 in x 7.4 in)
Weight
2.3 kg (6.5 lb)
http://www.elso.sk
Key features
•Simple installation and setup
(calibration controls easily
accessed through front panel)
•Anti-jam circuitry prevents
erroneous readings at tube
saturation
•LED digital display with Detector Fail indicator
•Programmable low and high
alarm indicators, with an
optional remote alarm available
•Data output/RS-232
Ordering information
05-443 PRIMALERT Digital Area
Monitor with internal energy
compensated 0.1 mR/hr to 1 R/hr GM
detector
05-443-2200 PRIMALERT Digital
Area Monitor with internal energy
compensated 1 µSv to 10 mSv/hr GM
detector, 220 V ac operation
05-446 Remote Display
Note: audible indicators can be configured as a single beep if desired.
Area Monitors
21
05-450
riešenia na presné meranie
PRIMALERT® Digital Doorway Monitor
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
n
The highly sensitive 05-450
PRIMALERT Digital Doorway Monitor
is designed to detect low levels of
gamma radiation that pass through
an entryway. Common installations of the 05-450 include hospital
entrances, emergency rooms, laundry
rooms, nuclear medicine labs and
procedure rooms, waste disposal
chutes and any other area of the hospital where radiation contamination
could be a concern.
The system consists of a digital
monitor, two shielded NaI (Tl)
scintillation detectors with NEMA
enclosures, associated cabling and a
10 µCi 137Cs check source. The system
is AC powered with internal battery
backup and user-selectable alarm
settings.
Key features
•Dual detectors—highly sensitive
lead shielded NaI (Tl) scintillators
•Configuration with NEMA
enclosures
•Fast response time with LED
digital display
•Audio and visual alarms
•Battery backup
Ordering information
05-450 PRIMALERT Digital Doorway
Monitor, Sv/hr, 220 V power
05-450-2200 PRIMALERT Digital
Doorway Monitor, Sv/hr, 220 V power
Specifications
Detectors
Two 3 in Ø x 1 in thick (7.6 cm x 2.5 cm) shielded NaI (Tl) scintillation detectors with up to 200 ft cables
(NEMA 4x enclosures included)
Connectors
BNC (others available on request)
Sensitivity
Detects an unshielded 40 µCi 137Cs source at 10 ft and unshielded 10 µCi 137Cs source at 5 ft from the detector
Check source
0.875 in Ø 10 µCi 137Cs check source
Display
4 digit LED display with 2 cm (0.8 in) character height
Display units
Can be made to display in µR/hr, mR/hr, R/hr, µSv/h, mSv/h, Sv/h, µrem/hr, mrem/hr, rem/hr, cpm, cps and others
Linearity
Reading within ± 10 % of true value with detector connected
Response
Typically 3 seconds from 10 % to 90 % of final reading
Status
(green light) Indicates the instrument is functioning properly
Low alarm
Indicated by a yellow light and slow beep (1 per sec) audible tone (can be set at any point from 0.0 to 9999)
High alarm
Indicated by a red light and fast beep (4 per sec) audible tone (can be set at any point from 0.0 to 9999)
Note: Audible indicators can be configured as a single beep if desired.
Detector fail
Indicates overload, no count from detector, or instrument failure (red light and audible tone; > 68 dB at 2 ft)
Low battery
Yellow light indicates < 2 hours of battery power remaining
High voltage
Adjustable from 200 V to 2500 V
Threshold
Adjustable from 2 mV to 100 mV
Dead time
Adjustable to compensate for dead time of the detector and electronics (can be read on the display)
Overload
Senses detector saturation (indicated by display reading “-OL”)
Overrange
Radiation field being measured exceeds the counting range of the instrument (indicated by display reading “----”)
Data output
9 pin connector providing 5 decade log output, RS-232 output, signal ground connection, FAIL and Alarm signals (current
sink), and direct connection to battery and ground
Power requirements
95 V ac to 135 V ac (178 V ac to 240 V ac available), 50 Hz to 60 Hz single phase (< 100 mA), 6 V sealed lead acid
rechargeable battery (built-in)
Battery life
Typically 48 hours in non-alarm condition, 12 hours in alarm condition
Battery charger
Battery is continuously trickle-charged when instrument is connected to line power and turned on
Battery dependence
< 3 % change in readings to battery endpoint
Temperature range
-20 °C to 50 °C (-4 °F to 122 °F). May be certified for operation from -40 °C to 65 °C (-40 °F to 150 °F)
Dimensioins
Electronics: 24.6 cm x 6.4 cm x 18.7 cm (9.7 in x 2.5 in x 7.4 in)
(WxDxH)
Detectors: 43.2 cm x 21.6 cm x 33 cm (17 in x 8.5 in x 13 in)
Weight
Electronics: 2.3 kg (6.5 lb)
Detectors: 14.5 kg (32 lb)
22
Area Monitors
http://www.elso.sk
riešenia na presné meranie
05-106
Bleeper mR Radiation Monitor
The slim, compact Bleeper mR
is the ideal personal monitoring
device for alerting personnel
to the presence of radiation in
medical, industrial or research
settings. It accurately measures
and displays the radiation dose
received.
The only control is a switch
to turnoff and reset the instrument, making Bleeper mR
extremely easy to use. For
added safety, the switch is
recessed. An easy-to-read LCD
display provides a continuous
indication of accumulated
dose. The loud “bleep” sounds
every 15 to 30 minutes on
background and becomes more
frequent as dose rate increases,
becoming a continuous sound
in high radiation fields. A series
of quiet “clicks” indicates it is
properly functioning. Bleeper
mR is an enhanced version of
the highly popular Bleeper III
and utilizes the same proven
technology.
Instrument CarePlans
Si
lv
er
ze
Biomedical Products
Br o
n
Key features
•Continuously monitors radiation
exposure and provides instant,
accurate readings
•Measures “x” and gamma
radiation
•Display can be easily read with
the instrument in-pocket
•Sturdy casing with pocket clip
protects against damage
•Features visible and audible
“battery low” indicators
•Good energy and polar
response…reliable readings
match those from TLDs and film
badges
•Recessed switch ensures the
Bleeper mR cannot be turned
off accidentally
Ordering information
05-106 Bleeper mR Radiation Monitor
05-106-2200 Bleeper µSv Radiation
Monitor
Specifications
Bleep rates for
background radiation
Approx. 1 bleep every 15 to 30 minutes
1 mR/h: approx. 1 bleep every 20 seconds
100 mR/h and above: continuous signal to at least
60 Sv/h (6000 R/h)
Energy range
45 keV to 6 MeV (± 25 %)
Doserate response
Linear to 5 R/h (± 20 %)
Display
LCD 0.1 mR to 999,999.9 mR
Battery
Three alkaline batteries, size AAA. Typical battery life is one year
Temperature range
-20 °C to 50 °C (-4 °F to 122 °F)
Dimensions (WxD)
3.56 cm x 15.24 cm (1.4 in x 6 in)
Display area
1.52 cm x 2.29 cm (0.6 in x 0.9 in)
Weight
0.11 kg (0.25 lb)
http://www.elso.sk
Personal Dosimetry
23
riešenia na presné meranie
06-007
Direct Reading Pocket Dosimeters
Key features
Instrument CarePlans
Si
er
ze
Biomedical Products
lv
Br o
n
Direct-Reading Pocket Dosimeters are rugged, precision instruments
designed specifically for measuring accumulated quantities of gamma and
x radiation. In use, the dosimeter is normally clipped to a pocket or to the
outside of a lead apron. By checking the dosimeter reading periodically, the
wearer is able to determine the exposure received during specific procedures. By knowing where and when greater-than-normal exposures occur,
the wearer can identify the source and take quick, corrective action. We
currently offers five dosimeters. Each dosimeter has a color-coded clip that
signifies its range. This will help the user to identify the dosimeter (i.e.
black clip = 0 to 200 mR, blue clip = 0 to 5 R, etc.), and ensure that the
intended dosimeter is utilized.
Direct-Reading Pocket Dosimeters are extremely easy-to-use. To read
the integrated exposure, the user looks through the dosimeter eyepiece
while pointing the unit toward any external light source. The exposure is
determined by the position of a hairline fiber against a graduated scale.
•Low leakage: measures background
•Superior energy response:
20 keV to 2 MeV
•Rugged: meets ANSI specifications N13.5 and N322
•Highly resistant to shock and
vibration
•Available in a wide selection
of ranges to meet all of your
requirements
Ordering information
06-007 Direct-Reading Pocket
Dosimeter, 0 to 200 mR; Black Clip
06-007-2200 Direct-Reading Pocket
Dosimeter, 0 to 2 mSv; Black Clip
06-638 Direct-Reading Pocket
Dosimeter, 0 to 200 R; Yellow Clip
06-686 Direct-Reading Pocket
Dosimeter, 0 to 600 R; Red Clip
06-912 Dosimeter Charger
Specifications
Radiation detected
Gamma and x-radiation from 20 keV to 2 MeV
Ranges
0 mR to 200 mR to 600 R
Energy response
160 keV to 2 MeV: ± 10 %
(see response curve) 40 keV to 160 keV: 20 %, -10 %
20 keV to 40 keV: 20 %, -30 %
24
Accuracy
Within ± 10 % of true exposure
Rate response
Dose rate independent for gamma and x-radiation
Electrical leakage
Less than 0.5 % of full scale for 24 hours at 50 °C
Relative humidity
Up to 90 %
Detector
Fiber electrometer mounted in an electrically-conducting plastic ion
chamber
Material
Detector housing: very low permeability plastics; hermetically-sealed
Clip: glass fiber-filled, high-strength plastic
Dimensions
1.5 cm x 12.4 cm (0.6 in Ø x 4.5 (l))
Weight
0.03 kg (0.06 lb)
Personal Dosimetry
http://www.elso.sk
A Dosimeter Charger (Model
06-912) is used to re-zero the
dosimeter.
The 0 to 200 mR LowEnergy Dosimeter is the most
popular type for measuring
personal radiation doses in
hospital applications including
fluoroscopy, portable radiography and angiography.
Our dosimeters are ideal
for nuclear medicine and
health physics applications.
All Direct-Reading Pocket
Dosimeters are hermeticallysealed using state-of-the-art
plastics and epoxy resins.
These reliable, high-quality
devices meet ANSI specifications N13.5 and N322, as well
as military requirements.
riešenia na presné meranie
Service and Calibration
World-class facility. World-class service.
Fluke Biomedical’s Global Calibration Lab
is NVLAP Lab Code 200566-0 accredited,
adheres to ISO 17025:2005, ANSI Z540,
Mammography MQSA, and CNSC, and is
traceable to national and international
standards.
Fluke Biomedical offers a variety of
Service Options to meet your needs.
These options include Asset-Management
for pools larger than 150 units, On-Site
calibration and Care Plan Options.
Asset-Management: Takes over your
grueling task of instrument tracking and
allows you to use your time more productively. Proper protocols are strictly
followed, eliminating the problems with
inspectors and audits that can result
when other less-qualified labs perform
the calibrations.
On-Site Calibrations: Minimizes
downtime and is scheduled when convenient for you. Calibrations are to OEM
requirements, completed OEM upgrades,
and Automatic OEM updates.
Care Plan Options: Fluke Biomedical’s Care Plan packages offer comprehensive priority service and support to help you get the most out of your
test equipment investments. As a member enjoy priority service, extended
warranties, value pricing on service, VIP technical support, xpedited return
shipping, and more.
Calibrate the following
•Area Monitors
•Barometers
•Blood Pressure Simulators
•Defibrillators/External Pace
Maker Analyzers
•Densitometers
•Diode Detectors
•Dosimeters
•Electrical Safety Analyzers
•Incubator Analyzers
•Ion Chambers
•IV Pump Analyzers
•kVp Meters
•mAs Meters
•Electrical Multimeters
•Oscilloscopes
•Patient Simulators
•Pressure Meters/Parameter
Testers
•Radiation Multimeters
•Sensitometers
•SpO2 Simulators/Analyzers
•Thermometers
•Test Lungs
•Ultra Sound Analyzers
•Velometers
•Ventilators/Gas flow Analyzers
Contact information
Calibration Beam Specifications
Radionuclide Calibrations
Radionuclide Sources
Minimum Rate
Maximum Rate
2000 Ci Cs-137
0.02 R/hr
850 R/hr
20 Ci Cs-137
0.1 mR/hr
4 R/hr
4 Ci Cs-137
0.5 mR/hr
1 R/hr
500 mCi Cs-137
0.04 mR/hr
150 mr/hr
1300 Ci Co-60
0.01 R/hr
450 R/hr
Collimated 2200 Ci Co-60
2575
3530
Service Center/Repair/Calibration US
Fluke Biomedical a division of Fluke
Electronics
6045 Cochran Road, Cleveland OH
44139-3303
Tel: 440-498-2560
Toll free: 800-850-4608 ext 2564
Email: [email protected]
Service Center/Repair/Calibration
Europe
Fluke Biomedical Europe
Science Park Eindhoven 5110, 5692EC
Son, The Netherlands
Tel: +31 (40) 267 5435
Fax: +31 (40) 267 5436
Email: [email protected]
www.flukebiomedical.com/service
http://www.elso.sk
Service and Calibration
25
riešenia na presné meranie
Publications
The following Fluke Biomedical catalogs are also available
Fluke Biomedical Imaging and Therapy QA
Diagnostic Imaging
Product Catalog
2011/2012
TNT 12000 X-Ray
Test Device
35080M/199XRAY kVp Divider
and Medical ScopeMeter
The Imaging and Therapy QA catalog is a comprehensive source book
of solutions for the Imaging QA Technologist, Physicist, Biomedical/
Clinical Engineer, or Service Engineer, and Radiation Oncology
Physicist, Therapist, and Dosimetrist. The catalog contains information
about the test devices, phantoms, and accessories, and linear
accelerator instruments and radiation oncology chambers needed to
manage imaging and therapy QA and maintain regulatory-compliance.
For more information, contact [email protected]
07-QRX Wireless QA RADCHEX
CR QC Productivity Device
Fluke Biomedical.
Better products. More choices. One company.
76-424-4156 Nested CT
Dose Phantom Kit for
Pediatric/Adult Head and Body
Fluke Biomedical Biomedical Test
The Biomedical Test catalog emphasizes the complete line of
biomedical test and simulation products for Biomedical/Clinical
Engineers and Technicians. The catalog contains information about
Fluke Biomedical’s test and simulation products, including standalone
electrical safety testers, patient simulators, and performance analyzers,
as well as fully integrated and automated performance-testing and
documentation systems.
For more information, contact [email protected]
Fluke Biomedical.
Better products. More choices. One company.
Fluke Biomedical
6045 Cochran Road
Cleveland, OH 44139-3303 U.S.A.
Your authorized Fluke Biomedical distributor
Fluke Biomedical Europe
Science Park Eindhoven 5110
5692EC Son, The Netherlands
riešenia na presné meranie™
Elso Philips Service; tel: +421 32 6582410
email: [email protected]; web: www.elso.sk
Featuring industry-standard Victoreen technology
http://www.elso.sk
For more information, contact us:
In the U.S.A. (800) 850-4608 or
Fax (440) 349-2307
In Europe/M-East/Africa +31 40 267 5435 or
Fax +31 40 267 5436
From other countries +1 (440) 248-9300 or
Fax +1 (440) 349-2307
Email: [email protected]
Web access: www.flukebiomedical.com
©2008-2011 Fluke Biomedical. Specifications subject
to change without notice. All OEM company trademarks
are implied. Printed in U.S.A. 5/2011 3038334C C-EN-N
Modification of this document is not permitted
without written permission from Fluke Corporation.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project