INDOOR/OUTDOOR PRODUCTS

KEROSENE PORTABLE

FORCED AIR HEATERS

“USER’S MANUAL AND

COMPLIES WITH UL733 AND

ANSI A10.10-1998

CAN/CSA/B140.0-03 AND CSA

B140.8-1967

MODEL : KFA50DGD, KFA75DGD, KFA125DGD

KFA170DGD, KFA210DGD

Before the first use of this heater, please read this USER’S MANUAL very carefully. This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heater in a safe and efficient manner.

Please keep this manual for future reference.

CONSUMER : Retain this manual for future reference.

Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 877-447-4768 8:30 a.m. - 4:30 pm CST, Monday - Friday.

or email us at [email protected]

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

DANGER::

IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH

FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON

MONOXIDE POISONING.

WARNINGS:

1. RISK OF INDOOR AIR POLLUTION!

Use this heater only in well ventilated areas. Provide at least a three-square foot (2,800 sq. cm.) opening of fresh outside air for each 100,000 BTU/hr. of heater rating.

People with breathing problems should consult a physician before using the heater.

Carbon monoxide poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness and/or nausea. If you have these signs, the heater may not be working properly.

Get fresh air at once! Have the heater serviced. Some people are more affected by carbon monoxide than others.

These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, or those at high altitudes.

Never use this heater in living or sleeping areas.

2. RISK OFBURNS/FIRE/EXPLOSION!

NEVER use any fuel other than 1-K kerosene, #1 disel/fuel oil in this heater.

NEVER use fuel such as gasoline, benzene, paint thinners or other oil compounds in this heater.

(RISK OF FIRE OR EXPLOSION)

NEVER use this heater where flammable vapors may be present.

NEVER refill the heaters fuel tank while heater is operating or is still hot.

CAUTION:

Hot while in operation. Do not touch. Keep children, clothing and combustibles away from heater.

Minimum Clearances: Outlet: 8 feet (250cm) / Sides, top and rear: 4 feet (125cm)

NEVER block air inlet (rear) or air outlet (front) of heater.

NEVER use duct work in front or behind of heater.

NEVER move, handle, service a hot, operating or plugged in heater.

NEVER transport heater with fuel in it’s tank.

When used with an optional thermostat or if equipped with a thermostat heater may start at any time.

ALWAYS locate heater on a stable and level surface.

ALWAYS keep children and animals away from heater.

Bulk fuel storage should be a minimum of 25 ft. from heaters, torches, portable generators or other sources of ignition.

All fuel storage should be in accordance with federal, state or local authorities having jurisdiction.

3. RISK OF ELECTRIC SHOCK!

• Use only the electrical power (voltage and frequency) specified on the model plate of the heater.

Use only a three-prong, grounded outlet and extension cord.

ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water or wind.

ALWAYS unplug the heater when not in use.

1

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

CONTENTS OF USER’S MANUAL

ITEM

P R E C

1

1 2

3

1

5

1

4

1

9

1

.

0 .

1 .

.

.

.

.

7

8

5

6

.

.

.

.

3 .

4 .

1 .

2 .

I

F

U

F

O

T

S

E

N

W

E

P

E

I

A

N

T

O S

V

N

N T

P L

R

P

I

U

A T

E

P

R

N

O

I

A

C

L

P A R T

U

I

T

R O D U

U R E S

C

K

O V

U

E

E

P E

L

R

I

R A

L

M

O

R E

R

X

A

G

A

N G

F

O

I

B

I

O

I

K

E

C

L

D

G

S L I

I

E

D

C

I

N

N

S

C

N

E

W

Y

S

T I

D

G

T I O N

T E

E N

E

E

R

N

A

I

S T

T

O U

M

P

I

-

( 1

O

A N

G

A

H

S A

A

S

O N

F

-

N

K

R

H

F E T Y G U I

O

T O

C E

D

E

A

R

A

H E

T

S S

N O

E

E

.

1

R

M B L Y

F U E L

A T E R

D

D

E

R A G E O F

S

E

Y

I

F U S E

O O T I N G G U I D E

G R A M

O

A

N

R

S

T S D R A W I N G

G N

O U

O I L )

R H E A T E R

1. INTRODUCTION

Please read this USER’S MANUAL carefully. It will show you how to assemble, maintain, and operate the heater safely and efficiently to obtain full benefits from its many built-in features.

2. FEATURES

Front Guard

Hot Air Outlet

Upper Shell

Handle

Lower Shell

Fan Guard

Fuel Tank

Side Cover

Lamp

Thermostot Knob

Power/Reset Switch

Power Cord

(Piggy Back, 75DGD Model Only)

Figure 1. KFA50DGD/75DGD MODELS

2

Fuel Gauge

Fuel Cap

PAGE #

1

1 5

6

9

1 0

4

8

8

6

7

2

4

1

2

1

1 7

18&21&24

19,20&22,23&25,26

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Hot Air Outlet

Shell Lower

Fuel Gauge

Fuel Cap

Side Cover

Lamp

Thermostot Knob

Room Temp. Display

(170DGD Model Only)

Power/Reset Switch

10” Flat Free Wheel

Front Handle

Upper Shell

Figure 2. KFA125/170DGD MODELS

Electric Outlet

Rear Handle

Cord Wrap

BTU Control Switch

Pressure Gauge

Fan Guard

Power Cord

(Piggy Back)

Fuel Drain Bolt

Front Handle

Upper Shell

Hot Air Outlet

Shell Lower

Fuel Gauge

Fuel Cap

Side Cover

Lamp

Thermostot Knob

Room Temp. Display

Power/Reset Switch

10” Flat Free Wheel

Rear Handle

Cord Wrap

BTU Control Switch

Pressure Gauge

Fan Guard

Power Cord

Fuel Drain Bolt

Figure 3. KFA210DGD MODEL

3

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

3. UNPACKING AND ASSEMBLY

1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig. 4 and 5)

NOTE : Save the shipping carton and packing materials for future storage.

Wheel Support Frame No

Wheel No

Threaded Axle

Front Handle

Rear Handle

H a n d el

C o r d W r a p

Hardware kit : HW-KFA1001

N o

N o

N o

Y

N e o

Yes

Hardware kit : HW-KFA1016 No s

KFA125DGD

Y

N o

Y e

No

Yes s

Yes

Yes

Y

Y e e e s s s

KFA210DGD

Y

N o

Y e

No

Yes s

Yes

Yes

Y

Y e e e s s s

Figure 4. KFA50DGD/75DGD MODELS

Handle

Figure 5. KFA125/170/210DGD MODELS

Screws

Flange Screws

Wheels

(10" Flat Free)

Nuts

Cap Nuts S

Bushings

Cap Nuts L

Cord Wraps

Hardware Kit : HW-KFA1016

Front Handle

Wheel Support Frame

Rear Handle

4

Axle

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

2. ASSEMBLY

For KFA50DGD/75DGD Models only

(Assembly time for this product is 3 minutes)

Tools Required

• Medium Phillips Screwdriver.

1) Lift front guard for arrow direction and make

sure that guard’s wedged portion fits into the slit

hole on the upper housing.

2) Align the holes in the upper housing with two

mounting holes on the handle as shown in Figure 6.

3) Secure handle with Screws with provided.

Handle

Screw

Front Guard

Wedged Portion

Slit Hole

Figure 6. Assembling Handle & Cord Wrap

For KFA125/170/210DGD Models only (Assembly time for this product is 10 minutes)

Tools Required

• Medium Phillips Screwdriver.

• 3/4 inch socket or adjustable wrench

Assembling Handle & Wheel and Cord Wrap

1) Slide threaded axle through the rear section of the wheel support frane.

2) Slide one axle bushing on to each side of the axle. Slide one wheel on to each side of the axle.

Attach one cap nut on to each side of the threaded axle and tighten well.

3) Place heater on wheel support frame. Align the holes on fuel tank flange with holes on wheel support frame.

4) Position the Handles on top of fuel tank flange.

Insert screws through handles, fuel tank flange and wheel support frames as shown in Figure 8 and

attach nut finger tight after each screw is inserted.

5) Align the hole on the handles with the mounting hole on the Cord Wrap.

Insert Screws through Cord Wrap, handles and attach nut finger tight after each screw is inserted.

6) After all screws are inserted, tighten nuts firmly.

5

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

Front Handle

Screw

Hot Air Outlet

Fuel Tank

Flange

Cap Nut S

Rear Handle

Cord Wrap

Flange Screw

Air Inlet

Wheel Support Frame

Nut

Wheel

Cap Nut L

Threaded Axle

Wheel Bushing

Figure 7. Assembling Handle, Wheel and Cord wrap

CAUTION : DO NOT OPERATE heater without support frame assembled to tank.

NOTE : Heater should be inspected before each use, and at least annually by a qualified service person.

4. KEROSENE (1-K)

For optimal performance of this heater, it is strongly suggested that 1-K kerosene be used. 1-K kerosene has been refined to virtually eliminate contaminants, such as sulpher. Which can cause a rotten egg odor during the operation of the heater. However, #1 diesel/fuel oil may also be used if 1-K kerosene is not available.

Be advised that these fuels do not burn as clean as 1-K kerosene, and care should be taken to provide more fresh air ventilation to accomodate any added contaminants that may be added to the heated space.

KEROSENE SHOULD ONLY BE STORED IN A BLUE CONTAINER THAT IS CLEARLY

MARKED “KEROSENE”. NEVER STORE KEROSENE IN A RED CONTAINER.

Red containers are associated with gasoline.

NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated place outside the living area.

NEVER use any fuel other than 1-K kerosene (#1 diesel and #1 oil are acceptable substitutes)

NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other oil compounds in this heater. These are volatile fuels that can cause an explosion or uncontrolled flames.

NEVER store kerosene in direct sunlight or near a source of heat.

NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time.

“OLD KEROSENE” WILL NOT BUR N PROPERLY IN THIS HEATER.

6

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

5. OVERVIEW OF HEATER’S DESIGN

Fuel System : This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through a nozzle in the burner head.

When the air passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle. This fuel and air mixture is then sprayed into the combustion chamber in a fine mist.

“Sure Fire Ignition” : The electronic ignitor sends voltage to a specially designed spark plug.

The spark plug ignites the fuel and air mixture described above.

The Air System : The heavy duty motor turns a fan that forces air into and around the combustion chamber.

Here the air is heated and then forced out the front of the heater.

The Safety System :

A. Temperature Limit Control : This heater is equipped with a Temperature Limit Control designed to turn off the heater should the internal temperature rise to an unsafe level. If this device activates and turns your heater off it may require service.

MODELS

KFA50DGD/75DGD

KFA125/170DGD

KFA210DGD

Internal Shut-Off Temp.

Plus/Minus 10 Degrees

176˚F/80˚C

230˚F/110˚C

194˚F/90˚C

Reset Temperature

Plus/Minus 10 Degrees

122˚F/50˚C

194˚F/90˚C

140˚F/60˚C

Once the temperature falls below the reset temperature you will be able to start your heater.

B. Electrical System Protection : This heater’s electrical system is protected by a fuse mounted to the PCB assembly that protects it and other electrical components from damage.

If your heater fails to operate check this fuse first and replace as needed.

FUSE TYPE:

All Models 125 volt / 8 amps

C. Flame-Out Sensor : Utilizes a photocell to monitor the flame in burn chamber during normal operation.

It will cause the heater to shut-off should the burner flame extinguish.

7

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

6. FUELING YOUR HEATER

NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK OUTDOORS.

DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED.

IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER :

The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in manufacturing the heater to burn off outside.

WARNING!! : NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR STILL HOT.

7. OPERATION

A.) VENTILATION

RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS.

Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr. rating. Provide extra fresh air if more heaters are being used.

Example : A KFA210DGD heater requires one of the following:

B.) OPERATION

• a two-car garage door raised six inches (15.24 cm)

• a single-car garage door raised nine inches (22.86 cm)

• two, thirty-inch (76.20 cm) windows raised fifteen inches (38.1 cm)

TO START HEATER

1. Fill fuel tank with kerosene or No. 1 fuel oil.

2. Attach fuel cap.

3. Plug power cord of heater into three-prong, grounded extension cord. Extension cord must be at least six feet long.

Extension Cord Wire Size Requirements

• 6 to 100 feet (1.8 to 30.5 meters) long, use 16 AWG conductor.

• 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.

4. Turn “THERMOSTAT CONTROL knob” to desired setting (setting range : 40˚F ~ 110˚F)

(KFA75DGD/KFA125/170/210DGD Models Only)

5. Push “BTU control Switch” to desired level “High or LOW” (See Figure 8.)

(KFA125/170/210DGD Models Only)

6. Push Power Switch to “ON” position, Power lndicator Lamp will light and heater will start.

NOTE : Room Temperature display explanations are as follows: (KFA170/210DGD Models only)

When the room temperature is less 0℉, the LED display will show “Lo”

When room temp is between 0℉ and 99℉, the number shown on the display is the current

room temperature.

When room temperature is greater than 99℉, the LED display will show “Hi”

If heater does not start, the thermostat setting may be too low, turn “thermostat Control Knob” to higher position to start heater. If heater still does not start, turn power switch to “OFF” and then to

“ON” position. If heater still does not start, see Troubleshootiong Guide on page15.

NOTE : User can Select to operate the heater on two different BTU levels(High or Low). The BTU level can

be selected before turning the unit on, or while it is in operation by pushing the BTU control switch.

Lamp

Lamp

Room Temp. Display

BTU Control Switch

BTU Control Switch

Push to “HIGH”

Push to “LOW”

Thermostat

Control Knob

(75/125DGD MODELS ONLY)

KFA50/75/125DGD Models KFA170/210DGD Models

Fan Guard

Figure 8. Controls for All Models

8

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the PCBboard.

If your heater fails to start, check this fuse first and replace as necessary. You should also check your

power source to insure that proper voltage and frequency are being supplied to the heater.

TO STOP HEATER

1. Turn switch to “OFF” and unplug power cord.

TO RESTART HEATER

1.Wait 10 seconds after stopping heater.

2. Repeat steps under to start heater.

EXTRA ELECTRIC OUTLET & PIGGYBACK POWER CORD

WARNING : SHOCK HAZARD!

C o v e r

• Always cover electric outlet when not in use.

• Don’t plug and use a appliance more than 120V/60Hz 5A current in this outlet

Outlet

C o v e r

Outlet

KFA210DGD Model Only KFA75DGD/125/170DGD Models only

Figure 9. Electric Outlet

8. LONG TERM STORAGE OF YOUR HEATER

FUEL TANK DRAIN

1. Drain fuel tank through fuel cap opening.

(For KFA50DGD/75DGD Models Only)

2. Remove fuel drain bolt from rear bottom side of fuel tank using 3/4” socket or adjustable wrench and drain.

(For KFA125/170/210DGD Models Only. See Figure 10)

3. Using a small amount of kerosene, swirl and rinse the inside of the tank.

NEVER mix water with the kerosene as it will cause rust inside the tank.

Pour the kerosene out making sure that you remove it all.

IMPORTANT : Do not store kerosene over summer months for use during next heating season.

Using old fuel could damage heater.

4. Reinstall fuel cap. Properly dispose of old and dirty fuel. (For KFA50DGD/75DGD Models Only)

5. Reinstall fuel drain bolt to Fuel tank and tighten firmly using 3/4” socket or adjustable wrench.

(For KFA125/170/210DGD Models Only. See Figure 10)

IMPORTANT : Before reinstalling the fuel drain bolt, make sure the seal is on the bolt. If the seal is

not used the bolt cannot be installed correctly and the fuel tank will leak.

Seal

Fuel Drain Bolt

Figure 10. Fuel Drain Bolt

6. Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.

7. Store the heater in the original box with the original packing material and keep the USER’S MANUAL with the heater.

9

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

9. MAINTENANCE

WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR

WHILE HOT!

USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or other alternate components will void warranty and may cause unsafe operating conditions.

A.) FUEL TANK

FLUSH EVERY 200 HOURS OF OPERATION OR

AS NEEDED (SEE STORAGE, PAGE 9)

Screw Upper Shell

Air Intake Filter

B.) AIR INTAKE FILTER

WASH AND DRY WITH SOAP AND WATER

EVERY 500 HOURS OF OPERATION OR AS

NEEDED.

- Remove screws along each side of heater using medium phillips screwdriver.

- Lift upper shell off.

- Remove fan guard.

- Wash or replace air intake filter.

- Reinstall fan guard and upper shell.

C.) AIR OUTPUT FILTER, LINT FILTER

REPLACE EVERY 500 HOURS OF OPERATION

OR ONCE A YEAR.

- Remove upper shell and fan guard (See Air Intake Filter).

- Trun Air pressure gauge counter-clock wise and remove.

- Remove end filter cover screws using medium phillips screwdriver.

- Remove end filter cover.

- Replace air output and lint filter.

- Reinstall end filter cover and air pressure gauge.

- Reinstall fan guard and upper shell.

Fan Guard

Figure 11. Air Intake Filter Access

Air Output Filter

End Filter Cover

Screw

Lint Filter

Pressure Gauge

Air Intake Filter

Figure 12. Air Outprt Filter Access

D.) FAN BLADES

CLEAN EVERY SEASON OR AS NEEDED.

- Remove upper shell (See Air Intake Filter).

- Use M6 allen wrench to loosen set screw which holds fan blade to motor shaft.

- Slip fan blade off motor shaft.

- Clean fan blade using a soft cloth moistened with kerosene or solvent.

- Dry fan blade thoroughly.

- Reinstall fan blade on motor shaft. Place fan blade hub flush with end of motor shaft.

- Place set screw on flat of shaft. Tighten set screw firmly (40-50 inch-pounds/4.5-5.6 N-m).

- Reinstall upper shell.

10

Flush

Set Screw

Motor Shaft

Fan Blade

Motor

Figure 13. Fan Assembly

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

E.) NOZZLE

REMOVE DIRT IN NOZZLE AS NEEDED (SEE PAGE 16).

(For KFA50DGD/75DGD/125/170DGD Models Only)

- Remove upper shell (See page 10).

- Remove fan blade (See page 10).

- Remove fuel and air line hoses from nozzle adaptor.

- Remove ignitor wire from spark plug.

- Remove spark plug from nozzle adaptor using medium

phillips screwdriver.

- Turn nozzle adaptor 1/9 turn(40°) to counter clock wise

and pull toward motor to remove. (See Figure 14)

- Place plastic hex-body into vise and lightlry tighten.

- Carefully remove nozzle from nozzle adaptor using 5/8”

socket wrench.

- Blow compressed air through face of nozzle.

(this will remove any dirt in nozzle)

- Reinstall nozzle into nozzle adaptor until nozzle seats.

Tighten 1/3 turn more using 5/8” socket wrench.

(40~45 inch-pounds)

- Reinstall nozzle adaptor to burner head.

- Reinstall spark plug to nozzle adaptor.

- Attach ignitor wire to spark plug.

- Attach fuel and air line hoses to nozzle adaptor.

- Reinstall fan blade and upper shell.

(For KFA210DGD Model Only)

- Remove upper shell (See page 10).

- Remove fan (See page 10).

- Remove fuel and air line hoses from nozzle adaptor.

- Remove ignitor wire from spark plug.

- Remove spark plug from nozzle adaptor using medium

phillips screwdriver.

- Turn nozzle adaptor 1/8 turn (45°) to counter clock wise

and pull toward motor to remove. (See Figure 15)

- Place plastic hex-body into vise and lightly tighten.

- Carefully remove nozzle from nozzle adaptor using 5/8”

socket wrench.

- Blow compressed air through face of nozzle.

(this will remove any dirt in nozzle)

- Reinstall nozzle into nozzle adaptor until nozzle seats

Tighten 1/3 turn more using 5/8” socket wrench

(40~45 inch-pounds)

- Reinstall nozzle adaptor to burner bracket

- Reinstall spark plug to nozzle adaptor.

- Attach ignitor wire to spark plug.

- Attach fuel and air line hoses to nozzle adaptor.

- Reinstall fan blade and upper shell.

Nozzle Face

Combustion Chamber

Screw

Ignitor Wire

Fuel Line

Air Line

Spark Plug

Nozzle Adaptor

Burner Head

Nozzle Face

Nozzle Adaptor

Nozzle

Nozzle Adaptor

Figure 14. Nozzle Replacement

Combustion Chamber

Screw

Ignitor Wire

Fuel Line

Spark Plug

Nozzle Adaptor

Bracket-Burner

Air Line

Nozzle Adaptor

Nozzle

Nozzle Adaptor

Figure 15. Nozzle Replacement

11

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

F.) SPARK PLUG

CLEAN AND REGAP EVERY 600 HOURS

OPERATION OR REPLACE AS NEEDED.

(For KFA50DGD/75DGD/125/170DGD Models Only)

- Remove upper shell (See page 10).

- Remove fan (See page 10).

- Remove ignitor wire from spark plug.

- Remove spark plug from nozzle adaptor using medium phillips screwdriver.

- Clean and regap spark plug electrodes to 3.5mm gap.

(0.138”)

- Reinstall spark plug to nozzle adaptor.

- Attach ignitor wire to spark plug.

- Reinstall fan and upper shell.

(For KFA210DGD Model Only)

- Remove upper shell (See page 10).

- Remove fan (See page 10).

- Remove ignitor wire from nozzle adaptor.

- Remove spark plug from nozzle adaptor using medium phillips screwdriver.

- Clean and regap spark plug electrodes to 3.5mm gap.

(0.138”)

- ReInstall spark plug to nozzle adaptor.

- Attach ignitor wire to spark plug.

- Reinstall fan and upper shell.

Spark Plug

Nozzle Adaptor

Ignitor Wire

Spark Plug

Figure 16. Spark Plug Regap

Screw

Nozzle Adaptor

Spark Plug

Screw

Spark Plug

Ignitor Wire

Figure 17. Spark Plug Regap

G.) PHOTOCELL

CLEAN PHOTOCELL ANNUALLY OR AS

NEEDED.

- Remove upper shell (See page 10).

- Remove fan (See page 10).

- Remove photocell from it’s mounting.

Clean photocell lens with cotton swab.

TO REPLACE:

- Remove side cover screws using medium phillips screwdriver.

- Disconnect switch wires from power switch and remove side cover.

- Disconnect wires from circuit board and remove photocell.

- Install new photocell and connect wires to circuit board.

- Replace switch wires to power switch and side cover.

- Replace fan and upper shell.

Side Cover

Bracket

Screw

Wire

Install Photocell

Incorrect Correct

Figure 18. Photocell Replacement

12

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

H.) FUEL FILTER

CLEAN OR REPLACE TWICE A HEATING

SEASON OR AS NEED.

- Remove side cover screws using medium phillips screwdriver.

- Disconnect switch wires from power switch and remove side cover.

- Pull fuel line off fuel filter neck.

- Turn fuel filter 90˚ to counter clockwise and pull to remove (KFA50DGD/75DGD Models only).

- Turn fuel filter 90˚ to clockwise and pull to remove

(KFA125/170/210DGD Models only).

- Wash fuel filter with clean fuel and replace in tank.

- Attach fuel line to fuel filter neck.

- Replace switch wires to power switch.

- Reinstall side cover.

Fuel Filter

Fuel line

Switch Wires

I.) PUMP PRESSURE ADJUSTMENT

NOTE: If the pump pressure needs to be adjusted,

make sure the heater is running on the

HIGH BTU setting.

- Push the BTU CONTROL Switch to HIGH.

(See Operation, page 8,

210DGD

Models only)

KFA125/170/

- Remove Pressure Gauge Plug from End Filter Cover.

Install accessory Pressure Gauge.

(KFA50DGD/75DGD Models only)

- Start heater (See Operation, page 8)

Allow motor to reach full speed

- Adjust pressure (Using a flat blade screwdriver) Turn relief valve to clockwise to increase pressure. Turn relief valve to counter clockwise to decreasepressure.

- Stop heater (See Operation, page 8)

MODEL

KFA50DGD

KFA75DGD

KFA125DGD

KFA170DGD

KFA210DGD

Pump Pressure

High BTU level Low BTU level

3.8 psi

3.8 psi

N/A

N/A

5.5 psi 3.5 psi

6.5 psi 4.5 psi

8.5 psi 6.5 psi

NOTE : USE ONLY ORIGINAL EQUIPMENT

REPLACEMENT PARTS.

Use of alternate or third party components will void any warranty and may cause unsafe operating condition.

Screw

Side Cover

Power Switch

Figure 19. Fuel Filter Replacement

End Filter Cover.

Pressure Gauge Plug

Pressure Gauge

KFA50DGD/75DGD Models Only

Relief Valve

Pressure Gauge

BTU Control Switch

Relief Valve

KFA125/170/210DGD Models only

Figure 20. Adjusting Pump Pressure

13

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

10. REPLACING FUSE

NOTICE : This heater is fuse protected.

If your heater fails to ignite, DO NOT RETURN YOUR HEATER TO THE

STORE.

Please follow the simple instructions below to inspect and change the fuse.

PROCEDURE FOR REPLACING FUSE

WARNING : SHOCK HAZARD

To prevent personal injury, unplug the power cord before replacing fuse.

1. Unplug heater.

2. Remove side cover screws using medium phillips screw driver.

3. Disconnect switch wires from power switch.

4. Remove fuse from fuse holder.(See Figure 21.)

5. Replace fuse with enclosed fuse.

WARNING : FIRE HAZARD

To avoid fire, Do not substitute with a higher or lower current rating.

6. Replace switch wires to power switch.

7. Replace side cover.

Fuse

Fuse Holder

NOTE : Specified fuse rating : AC 125/8A

KFA75DGD/125/170/210DGD Models

Screw

Side Cover

Power Switch

Switch Wire

Figure 21. Replacing Fuse

14

Fuse

Fuse Holder

KFA50DGD

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

11. TROUBLE SHOOTING GUIDE

TROUBLE

Heater ignites but MAIN PCB assembly shuts heater off after a short period of time.

(Indicator Lamp is flickering and room temp. display indicates " E1 ")

POSSIBLE CAUSE

1. Wrong pump pressure

2. Dirty Air Output,Air Intake or Lint Filter.

3. Dirty Fuel Filter.

4. Dirt in Nozzle.

5. Dirty Photocell Lens.

6. Photocell Assembly not

Properly installed.(Not seeing the flame)

7. Bad electrical connection between photocell and MAIN

PCB assembly.

8. Defective Photocell.

Heater will not ignite but motor runs for a short period of time.(Indicator Lamp is flickering and room temp.display indicates " E1 ")

Fan does not turn when heater is plugged in and power switch was in the " ON " Position.

(Indicator Lamp is on or flickering)

1. No fuel in tank.

2. Wrong pump pressure.

3. Carbon deposits on spark plug and/or improper gap.

4. Dirty fuel filter.

5. Dirt in Nozzle.

6. Water in fuel tank.

7. Bad electrical connection between ignitor and MAIN

PCB assembly.

8. Ignition wire is not attached to spark plug.

1. Thermostat setting is too low.

(Indicator Lamp is flickering and room temp. display indicates "E2")

2. Bad electrical connection

between motor and MAIN

PCB assembly.

1. Room Temp. sensor disconnected.

2. Sensor Failure.

(Indicator Lamp is flickering and room temp. display indicates "E3")

Heater will not turn-on

(Indicator Lamp is off)

1. Thermostat switch failure.

1. Temperature limit safety

device is overheated.

2. No electrical power

3. Blown fuse.

4. Bad electrical connection between

temperature limit safety device

and PCB board.

15

CORRECTIVE ACTION

1. See Pump Pressure Adjustment,

Page 13.

2. See Air Output, Air intake and Lint Filters, page 10.

3. See Fuel Filter, Page 13.

4. See Nozzle, Page 11.

5. Clean Photocell Lens, Page 12.

6. Make sure photocell boot is properly seated in bracket,

Page 12.

7. Check electrical components

See wiring diagram, Page 16.

8. Replace Photocell, Page 12.

1. Fill tank with kerosene.

2. See Pump Pressure Adjustment,

Page 13.

3. See Spark Plug, Page 12.

4. See Fuel Filter, Page 13.

5. See Nozzle, Page 11.

6. Flush fuel tank with clean kerosene, Page 9.

7. Check electrical components

See wiring diagram, Page 16.

8. Attach ignition wire to spark plug. See Spark Plug, Page 12.

1. Turn thermostat control knob to a higher setting.

2. Check electrical connections,

See Wiring Diagram, Page 16.

1. Reconnect sensor.

See Wiring diagram, Page 16.

2. Replace sensor.

See Wiring diagram, Page 16.

1. Replace switch.

See Wiring diagram, Page 16.

1. Turn power switch to "OFF" and allow to cool (about 10 min.)

2. Check to insure heater cord and extension cord are plugged in.

Check power supply.

3. Replace safety fuse in PCB board.

4. Check electrical connections

See Wiring Diagram, Page 16.

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

12. WIRING DIAGRAM

A) WIRING DIAGRAM (KFA50DGD Model)

CN1 CN1

CN2

CN3

CN7

CAPACITOR

15uF/230VAC

B) WIRING DIAGRAM (KFA75DGD/125/170DGD Models)

CN4

CN3

CN5 CN6

MODEL

75DGD

125DGD

170DGD

1/G WIRE

COLOR

BLACK

RED

BLACK

WHITE

BLACK

BLUE

CAPACITOR

15uF/230VAC

20uF/350VAC

20uF/350VAC

C) WIRING DIAGRAM (KFA210DGD Model)

CN4

CN3

CAPACITOR

20uF/350VAC

CN5 CN6

16

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

13. SPECIFICATIONS

32.0"(813mm) 11.7"(297mm)

KFA50DGD/75DGD Models

D

H

W

KFA125/170/210DGD Models

125DGD

D

W

H

41.9"(1,063 mm)

21.5"(547 mm)

32.4"(824 mm)

170DGD

210DGD

47.4"(1,205 mm)

23.1"(587 mm)

33.5"(850 mm)

MODEL

BTU/Hr.

Fuel Consumption

- Gal./Hr( ./Hr)

Fuel Tank Capacity - Gal.( )

HIGH

LOW

HIGH

LOW

Pump Pressure PSI(kgf/㎠)

HIGH

LOW

V lo

A m p

/t H z

.s

P h a s e

Size(D×W×H), Inch(㎜)

Weight Lbs.(㎏)

KFA50DGD KFA75DGD KFA125DGD KFA170DGD KFA210DGD

50,000 75,000 125,000 170,000 210,000

N/A

0.38(1.44)

N/A

0.57(2.16)

100,000

0.95(3.60)

135,000

1.30(4.92)

170,000

1.60(6.06)

N/A

5.0(18.9)

3.8(0.27)

N/A

N/A

5.0(18.9)

3.8(0.27)

N/A

0.76(2.90)

10.0(37.9)

5.5(0.39)

3.5(0.25)

1.0(3.79)

13.0(49.2)

6.5(0.46)

4.5(0.32)

1.30(4.92)

13.0(49.2)

8.5(0.60)

6.5(0.46)

120Vac/60hz

1.6

1

120Vac/60hz

1.6

1

120Vac/60hz

2.5

1

120Vac/60hz

3.2

1

120Vac/60hz

3.7

1

32.0×11.7×16.7

(813×297×424)

26.9(12.2)

32.0×11.7×16.7

(813×297×424)

26.9(12.2)

41.9×21.5×32.4

(1,063×547×824)

54.5(24.7)

47.4×23.1×33.5

(1,205×587×850)

60.2(27.3)

47.4×23.1×33.5

(1,205×587×850)

62.4(28.3)

17

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

14. EXPLODED PARTS DRAWING (KFA50DGD/75DGD Models Only)

NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS.

3

43

19

42

11

1

13

39

20

17

18

14

25

15

4

31

40

21

22

23 24

28

27

26

23-1

23-2

23-4

23-6

41

23-3

23-5

32

12

16

30

37

29

10

38

36

35

5

33

34

9

8

2

6

23-8

23-7

26-1

26-3

7

26-2

26-5

26-4

26-10

26-12

26-13

26-14

26-20

26-6

26-7

26-9

26-8

26-11

26-15

26-16

26-17

26-18

26-21

26-19

18

DESCRIPTION

Fuel Tank Assmebly

Fuel Drain-Bolt

Fuel Gauge

Fuel Filter Assmbly

Fuel Cap

Cord Bushing

Power Cord

Thermistor

Button Support

Display P.C.B Assembly

Shell Lower

Flange Screw

Clip Nut

Bushing-Grommet(S)

Bushing-Grommet(L)

Air-Line

Temperature Limit Assembly

Flange-Screw

Chamber Assembly

Bracket Photocell

Screw-BH1

Photocell Assembly

Burner Head Assembly

Burner Head

Nozzle

Washer-Nozzle Seal

Spring-Nozzle Seal

O-Ring

Nozzle Adaptor

Spark Plug

Bolt-Flange

Flange Screw

Fuel Line

Motor and Pump Assembly

Motor

Capacitor

Motor Support

Nut-Hex

Holder Capacitor

Pump Body

Bolt-BH Special

Rotor

Blade

Insert

End Pump Cover

Elbow

KEY NO.

23-2

23-3

23-4

23-5

23-6

23-7

23-8

24

17

18

19

20

21

22

23

23-1

13

14

15

16

9

10

11

12

7

8

5

6

3

4

1

2

26-7

26-8

26-9

26-10

26-11

26-12

25

26

26-1

26-2

26-3

26-4

26-5

26-6

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (KFA50DGD/75DGD Models Only)

KFA50DGD

PART NO.

2153-0022-00

4319-0015-00

2152-0115-00

3131-0159-00

4311-0068-00

*SP-KFA1007

2152-0120-00

3531-0026-00

*SP-KFA1026

4349-0016-00

3431-0010-00

3311-0002-00

3231-0178-00

*SP-KFA1008

4329-0079-00

4319-0015-00

-

2151-0026-00

2156-0047-00

2155-0005-00

2151-0003-00

3712-0013-00

3980-0031-00

38C0-0054-00

3713-0048-00

215A-0013-00

3111-0343-05

4319-0015-00

3131-0182-00

3231-0120-00

3231-0121-00

3341-0021-00

3341-0024-00

2154-0078-00

3970-0210-00

3820-0257-00

3121-0481-00

4331-0022-00

-

3541-0022-00

4321-0198-00

See SP-KFA1000

See SP-KFA1000

See SP-KFA1000

3531-0027-00

3231-0181-00

1

1

1

19

KFA75DGD

2153-0022-00

4319-0015-00

2152-0116-00

3131-0159-00

4311-0068-00

*SP-KFA1007

2152-0121-00

3531-0026-00

*SP-KFA1027

4349-0016-00

3431-0010-00

3311-0002-00

3231-0178-00

*SP-KFA1008

4329-0079-00

4319-0015-00

-

2151-0027-00

2156-0049-00

2155-0005-00

2151-0003-00

3712-0013-00

3980-0177-00

38C0-0054-00

-

-

3111-0343-05

4319-0015-00

3131-0182-00

3231-0120-00

3231-0121-00

3341-0021-00

3341-0024-00

2154-0078-00

3970-0210-00

3820-0257-00

3121-0481-00

4331-0022-00

-

3541-0022-00

4321-0198-00

See SP-KFA1000

See SP-KFA1000

See SP-KFA1000

3531-0027-00

3231-0181-00

1

1

1

Quantity

1

3

1

1

1

1

1

2

1

1

2

1

1

1

1

1

1

1

8

1

1

4

2

1

1

1

1

1

1

1

1

1

4

1

2

1

1

1

1

1

1

2

1

1

1

1

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (KFA50DGD/75DGD Models Only)

KEY NO.

30

31

32

33

26-21

27

28

29

26-13

26-14

26-15

26-16

26-17

26-18

26-19

26-20

38

39

40

41

34

35

36

37

42

43

DESCRIPTION

Lint Filter

Bolt Flange

Output Filter

End Filter Cover

Ball

Spring

Adjusting Screw

Bolt Flange

Intake Filter

Fan Assembly

Bolt Headless Hex Socket

Plug

Main P.C.B Assembly

Screw-TH2S

Ignitor

Side Cover-Right

Power Switch

Window Display

Flange Screw

Side Cover-Left

Flange Screw

Shell Upper

Clip Nut

Fan Guard

Flange Screw

Front Guard

KFA50DGD

PART NO.

See SP-KFA1005 2

4329-0016-00

See SP-KFA1005 2

3221-0029-00

See SP-KFA1006 3

See SP-KFA1006 3

See SP-KFA1006 3

4329-0016-00

See SP-KFA1005

2

2154-0009-00

4323-0004-00

3231-0054-00

215A-0048-00

4312-0046-00

39E0-0008-00

3121-0496-04

39A0-0191-00

-

4319-0015-00

3121-0190-00

4319-0015-00

3111-0347-05

3131-0182-00

3221-0050-00

4319-0015-00

3561-0066-00

KFA75DGD

See SP-KFA1005

4329-0016-00

See SP-KFA1005

3221-0029-00

See SP-KFA1006

See SP-KFA1006

See SP-KFA1006

4329-0016-00

See SP-KFA1005

2154-0009-00

4323-0004-00

3231-0054-00

215A-0046-00

4312-0046-00

39E0-0008-00

3121-0497-05

-

39A0-0191-00

4319-0015-00

3121-0350-00

4319-0015-00

3111-0347-05

3131-0182-00

3221-0050-00

4319-0015-00

3561-0066-00

2

2

3

3

3

2

Quantity

1

1

1

2

1

1

1

1

1

4

1

1

1

1

1

6

2

1

4

1

8

1

4

1

1

1

KEY NO.

1

2

3

DESCRIPTION

Rotor kit

Filter kit

Plug/Pump adjuster kit

KFA50DGD

PART NO.

SP-KFA1000

SP-KFA1005

SP-KFA1006

KFA75DGD

SP-KFA1000

SP-KFA1005

SP-KFA1006

FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR

CONTACT US AT:

Phone : 1-877-447-4768

Quantity

1

1

1

20

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

14. EXPLODED PARTS DRAWING (KFA125/170DGD Models Only)

NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS.

3

17

40

9

1

11

38

18

15

16

12

23

13

4

30

19

20

21 22

26

25

24

31

10

14

29

27

36

28

21-1

21-2

21-4

21-6

21-3

21-5

39

37

35

34

5

32

33

8

2

21-8

21-7

6

21

7

24-1

24-3

24-2

24-5

24-6

24-7

24-9

24-8

24-11

24-15

24-4

24-10

24-12

24-13

24-14

24-20

24-19

24-16

24-17

24-18

24-21

DESCRIPTION

Fuel Tank Assmebly

Fuel Drain-Bolt

Fuel Gauge

Fuel Filter Assmbly

Fuel Cap

Cord Bushing

Power Cord

Thermistor

Shell Lower

Flange Screw

Clip Nut

Bushing-Grommet(S)

Bushing-Grommet(L)

Air-Line

Temperature Limit Assembly

Flange-Screw

Chamber Assembly

Bracket Photocell

Screw-BH1

Photocell Assembly

Burner Head Assembly

Burner Head

Nozzle

Washer-Nozzle Seal

Spring-Nozzle Seal

O-Ring

Nozzle Adaptor

Spark Plug

Bolt-Flange

Flange Screw

Fuel Line

Motor and Pump Assembly

Motor

Capacitor

Motor Support

Nut-Hex

Holder Capacitor

Pump Body

Bolt-BH Special

Rotor

Blade

Insert

End Pump Cover

Elbow

Lint Filter

Bolt Flange

KEY NO.

21-4

21-5

21-6

21-7

21-8

22

23

24

17

18

19

20

21

21-1

21-2

21-3

13

14

15

16

9

10

11

12

7

8

5

6

3

4

1

2

24-9

24-10

24-11

24-12

24-13

24-14

24-1

24-2

24-3

24-4

24-5

24-6

24-7

24-8

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (KFA125/170DGD Models Only)

KFA125DGD

2152-0117-00

3131-0159-00

4311-0068-00

*SP-KFA1007

2152-0122-00

3531-0025-00

*SP-KFA1003

4349-0016-00

3431-0010-00

3311-0002-00

3231-0179-00

*SP-KFA1009

4329-0079-00

4319-0015-00

3341-0025-00

2154-0075-00

2151-0028-00

4329-0072-00

2156-0050-00

2155-0001-00

2151-0003-00

3712-0013-00

3980-0177-00

38C0-0054-00

3111-0344-05

4319-0015-00

3131-0182-00

3231-0120-00

3231-0121-00

3341-0002-00

2153-0023-00

4319-0015-00

3970-0211-00

3820-0258-00

3121-0482-00

4331-0022-00

3231-0180-00

3541-0022-00

4321-0198-00

See SP-KFA1000

See SP-KFA1000

See SP-KFA1000

3531-0027-00

3231-0181-00

See SP-KFA1005

4329-0016-00

1

1

1

2

PART NO.

KFA170DGD

2152-0118-00

3131-0159-00

4311-0068-00

*SP-KFA1007

2152-0123-00

3531-0024-00

*SP-KFA1004

4349-0016-00

3431-0010-00

3311-0002-00

3231-0179-00

*SP-KFA1009

4329-0079-00

4319-0015-00

3341-0025-00

2154-0076-00

2151-0029-00

4329-0072-00

2156-0051-00

2155-0001-00

2151-0003-00

3712-0013-00

3980-0177-00

38C0-0054-00

3111-0345-05

4319-0015-00

3131-0182-00

3231-0120-00

3231-0121-00

3341-0022-00

2153-0023-00

4319-0015-00

3970-0212-00

3820-0258-00

3121-0482-00

4331-0022-00

3231-0182-00

3541-0022-00

4321-0198-00

See SP-KFA1000 1

See SP-KFA1000 1

See SP-KFA1000 1

3531-0027-00

3231-0181-00

See SP-KFA1005 2

4329-0016-00

22

Quantity

1

1

1

3

1

1

1

1

1

2

1

1

2

1

1

1

1

1

1

1

8

1

1

4

1

1

1

1

1

1

1

1

1

1

4

1

1

6

2

1

1

1

1

2

1

1

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (KFA125/170DGD Models Only)

KEY NO.

30

31

32

33

26

27

28

29

24-15

24-16

24-17

24-18

24-19

24-20

24-21

25

38

39

40

34

35

36

37

DESCRIPTION

Output Filter

End Filter Cover

Ball

Spring

Adjusting Screw

Bolt Flange

Intake Filter

Fan Assembly

Bolt Headless Hex Socket

Pressure Gauge

BTU Control Switch

Main P.C.B Assembly

Screw-TH2S

Ignitor

Side Cover-Right

Power Switch

Window Display

Flange Screw

Side Cover-Left

Flange Screw

Shell Upper

Fan Guard

Flange Screw

KFA125DGD

See SP-KFA1005

3221-0076-00

See SP-KFA1010

See SP-KFA1010

See SP-KFA1010

4329-0016-00

See SP-KFA1005

2154-0004-00

4323-0004-00

3740-0049-00

2154-0070-00

215A-0046-00

4312-0046-00

39E0-0005-00

3121-0510-00

39A0-0191-00

-

4319-0015-00

3121-0352-00

4319-0015-00

3111-0348-05

3221-0075-00

4319-0015-00

2

3

3

3

2

PART NO.

KFA170DGD

See SP-KFA1005 2

3221-0076-00

See SP-KFA1010 3

See SP-KFA1010 3

See SP-KFA1010 3

4329-0016-00

See SP-KFA1005 2

2154-0007-00

4323-0004-00

3740-0049-00

2154-0070-00

215A-0047-00

4312-0046-00

39E0-0007-00

3121-0499-05

39A0-0191-00

3231-0113-00

4319-0015-00

3121-0354-00

4319-0015-00

3111-0349-05

3221-0075-00

4319-0015-00

Quantity

1

1

2

1

1

1

1

1

1

1

2

4

2

2

1

1

1

1

8

1

4

1

4

KEY NO.

1

2

3

DESCRIPTION

Rotor kit

Filter kit

Plug/Pump adjuster kit

KFA125DGD

SP-KFA1000

SP-KFA1005

SP-KFA1010

PART NO.

KFA170DGD

SP-KFA1000

SP-KFA1005

SP-KFA1010

FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR

CONTACT US AT:

Phone : 1-877-447-4768

Quantity

1

1

2

23

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

14. EXPLODED PARTS DRAWING (KFA210DGD Model Only)

NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS.

41

21-1

3

17

44

9

1

11

18

15

16

12

23 13

4

30

19

20

21

22

26

25

24

31

10

14

29

27

36

21-2

21-4

21-6

43

28

40

37

38

39

42

21-3

21-5

21-7

21-8

35

34

5

32

33

8

2

6

24

7

24-1

24-3

24-2

24-5

24-6

24-7

24-9

24-8

24-11

24-15

24-4

24-10

24-12

24-13

24-14

24-20

24-19

24-16

24-17

24-18

24-21

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (KFA210DGD Model Only)

DESCRIPTION

Fuel Tank Assmebly

Fuel Drain-Bolt

Fuel Gauge

Fuel Filter Assmbly

Fuel Cap

Cord Bushing

Power Cord

Thermistor

Shell Lower

Flange Screw

Clip Nut

Bushing-Grommet(S)

Bushing-Grommet(L)

Air-Line

Temperature Limit Assembly

Flange-Screw

Chamber Assembly

Bracket Photocell

Screw-BH1

Photocell Assembly

Burner Head Assembly

Bracket Burner

Nozzle

Washer-Nozzle Seal

Spring-Nozzle Seal

O-Ring

Nozzle Adaptor

Spark Plug

Bolt-Flange

Flange Screw

Fuel Line

Motor and Pump Assembly

Motor

Capacitor

Supportor Motor

Nut-Hex

Holder Capacitor

Pump Body

Bolt-BH Special

Rotor

Blade

Insert

End Pump Cover

Elbow

Lint Filter

Bolt Flange

KEY NO.

21-4

21-5

21-6

21-7

21-8

22

23

24

17

18

19

20

21

21-1

21-2

21-3

13

14

15

16

9

10

11

12

7

8

5

6

3

4

1

2

24-9

24-10

24-11

24-12

24-13

24-14

24-1

24-2

24-3

24-4

24-5

24-6

24-7

24-8

25

PART NO.

KFA210DGD

2152-0119-00

3131-0159-00

4311-0068-00

*SP-KFA1007

2152-0124-00

3121-0477-00

*SP-KFA1011

4349-0016-00

3431-0010-00

3311-0002-00

3231-0180-00

*SP-KFA1021

4329-0079-00

4319-0015-00

3341-0019-00

2154-0077-00

2151-0029-00

4329-0072-00

2156-0052-00

2155-0001-00

2151-0003-00

3712-0013-00

3980-0087-00

38C0-0054-00

3111-0346-05

4319-0015-00

3131-0182-00

3231-0120-00

3231-0121-00

3341-0023-00

2153-0005-00

4319-0015-00

3970-0213-00

3820-0258-00

3121-0482-00

4331-0022-00

3231-0180-00

3541-0050-00

4321-0198-00

See SP-KFA1022 1

See SP-KFA1022 1

See SP-KFA1022 1

3531-0008-00

3231-0181-00

See SP-KFA1005 2

4329-0016-00

Quantity

1

1

1

4

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

8

1

1

4

1

1

1

1

1

1

1

1

1

1

4

1

1

6

2

1

1

1

1

2

1

1

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (KFA210DGD Model Only)

KEY NO.

38

39

40

41

34

35

36

37

42

43

44

30

31

32

33

26

27

28

29

24-15

24-16

24-17

24-18

24-19

24-20

24-21

25

.

DESCRIPTION

Output Filter

End Filter Cover

Ball

Spring

Adjusting Screw

Bolt Flange

Intake Filter

Fan Assembly

Bolt Headless Hex Socket

Pressure Gauge

BTU Control Switch

Main P.C.B Assembly

Screw-TH2S

Ignitor

Side Cover-Right

Power Switch

Window Display

Flange Screw

Side Cover-Left

Electirc Outlet Assembly

Cover Outlet

Screw-Top Table

Flange Screw

Shell Upper

Fan Guard

Bushing Fan Guard

Flange Screw

PART NO.

KFA210DGD

See SP-KFA1005 2

3221-0076-00

See SP-KFA1010 3

See SP-KFA1010 3

See SP-KFA1010 3

4329-0016-00

See SP-KFA1005 2

2154-0007-00

4323-0004-00

3740-0049-00

2154-0070-00

215A-0047-00

4312-0046-00

39E0-0014-00

3121-0499-10

39A0-0191-00

3231-0113-00

4319-0015-00

3121-0329-00

39D0-0263-00

3231-0114-00

.

3111-0350-05

3561-0078-00

3351-0010-00

4319-0015-00

KEY NO.

1

2

3

DESCRIPTION

Rotor kit

Filter kit

Plug/Pump adjuster kit

PART NO.

KFA210DGD

SP-KFA1022

SP-KFA1005

SP-KFA1010

FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR

CONTACT US AT:

Phone : 1-877-447-4768

Quantity

1

1

2

Quantity

4

1

1

1

1

1

1

4

1

3

8

1

1

2

1

1

1

1

1

1

1

2

4

2

2

1

1

26

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

15. PARTS LIST (WHEELS AND HANDLE)

1) KFA50DGD/75DGD MODELS

KEY NO. DESCRIPTION

1

2

Handle

Hardware Kit

KFA50DGD

3231-0073-00

HW-KFA1001

PARTNO.

KFA75DGD

3231-0073-00

HW-KFA1001

Quantity

1

1

KEY NO.

5

6

7

7-1

3

4

1

2

7-2

7-3

7-4

7-5

7-6

2) KFA125/170/210DGD MODELS

DESCRIPTION

Front Handle

Rear Handle

Wheel Support Frame

Wheel

Threaded Axle

Cord Wrap

Hardware Kit

Screw

Flange Screw

Cap Nut S

Nut

Bushing

Cap Nut L

PARTNO.

KFA125DGD KFA170/210DGD

3551-0023-00

3551-0096-00

3551-0082-00

3720-0017-00

3551-0088-00

3221-0042-00

HW-KFA1016

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

3551-0022-00

3551-0097-00

3551-0084-00

3720-0017-00

3551-0089-00

3221-0042-00

HW-KFA1016

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

INCLUDED IN HARDWARE KIT

1

7-1

7-3

2

6

7-2

Quantity

1

8

1

2

1

2

1

1

8

2

4

4

2

2

1

7-4

4

7-6

3

7-5

5

27

GHP Group, Inc.

6440 W Howard St

Niles, IL 60714-3302

Tel: (877) 447-4768 www.ghpgroupinc.com

GHP Group, Inc.

6440 W Howard St

Niles, IL 60714-3302