SANYO 2010 Electric VRF Brochure

Add to my manuals
37 Pages

advertisement

SANYO 2010 Electric VRF Brochure | Manualzz

Electric VRF

Room Air Conditioners

Commercial Split Systems

Gas Driven VRF

Heating Solutions

Electric VRF

Contents

V2 Electric VRF, ECOi

V4 ECOi 6 Series VRF

V6 2 Way ECOi

V8 3 Way ECOi

V12 Mini ECOi

A1 VRF Indoor Unit Range

A3 X type

A5 XM type

A7 LDR type

A9 DR type

A11 US type

A13 U type

A15 FTR type

A17 T type

A19 K type

A21 KR type

A23 FR type

A25 FMR type

A27 GU type

A29 CFR type

A31 VRF Indoor Unit Dimensions

C1 System Controls for VRF

C3 Individual Control Systems

C5 Centralised Control Systems

C9 Interfaces for External Control

C11 BMS Software

C13 PAC2 System Design Software

C15 Control Equipment External

Dimensions

SANYO

From the familiar to the super specialised – SANYO’s technologies are hard at work in many fields. Some examples might include the refrigerated showcases at the local supermarket, the information device at the hospital, and the large air conditioners at public facilities.

SANYO’s technologies can be found throughout the world and in every field. Not only that, but they boast the kind of quality that satisfies high-level professionals in those fields.

Introducing SANYO Electric VRF

2010 sees the launch of the new series 6 high efficiency heat pump VRF system. The future is here today…

Constantly outperforming the competition for performance and reliability the SANYO

ECOi range is an obvious choice when a

VRF solution is required.

Over 20 years of research, development and production history ensures that

SANYO’s range matches and exceeds the market’s needs.

We are never standing still and 2010 sees a new range of 2 way heat pump outdoor units with several new and unique functions.

• Outdoor capacities from 10kW – 150kW

• 15 types of indoor units to suit all applications

• DC inverter technology throughout the range

• BMS interface

• Remote monitoring and control

Electric VRF, ECOi

V1

Electric VRF, ECOi

Since its formation in 1958,

SANYO Air Conditioners has been at the forefront of innovation with its market leading research and development program.

From the world’s first heat pump air conditioner in 1960 to the first 3 pipe VRF system in 1989, SANYO continues to deliver leading technology combined with the reliability and customer service that you would expect from SANYO.

The ever-evolving SANYO ECOi series

The ECOi series is designed for energy savings, easy installation, and high efficiency. Always continuing to evolve,

SANYO uses advanced technologies to meet the requirements of diverse situations and contribute to the creation of comfortable living spaces.

Lower running and life cycle costs

SANYO ECOi VRF systems are amongst the most efficient

VRF systems on the market, offering COPs in excess of 4.0 at full load conditions. The system is also designed to make sure that we reduce the running cost of each system by using our unique road map control routine to ensure that the most efficient combination of compressors are running at any one time. Improved defrost sequencing also reduces running cost by defrosting each outdoor coil in turn when conditions allow.

3 way ECOi

Simultaneous heating and cooling operation

Heat Recovery Type

• Simultaneous cooling or heating operation for up to 40 indoor units

• Top Class COP

• Realisation of the smallest installation space, top class in the industry

• Rotation operation function and back-up operation function provided

• Changeover boxes do not need any power supply

Electric VRF, ECOi

2 way ECOi

The new ECOi 6 series is specifically designed for energy saving, easy installation and high efficiency performance as its main focus.

• Full and extended range (8, 10, 12, 14, 16, 18, 20HP)

• Full Hi COP range (10, 12, 14, 16HP)

• DC inverter technology for precise temperature control and a low start-up current

• Improved COP and EER by new design for heat exchangers, fans, fan motors and compressors.

• High external static pressure available (80Pa)

• 64 indoor unit connectability from 38hp (107kW)

• Connectable indoor unit capacity ratio up to 200%

• Non stop operation during maintenance

• Extended operating range ( -25°C in heating mode)

• Extended pipe runs (Max pipe length 1000m)

• Automatic backup operation

• Extended compressor life by operation time sharing

• Suitable for use with renewal technology

Mini ECOi Outdoor Units

For light commercial use

• Single phase or three phase power supply

• DC inverter technology combined with R410A for excellent efficiency

• Compact design for easy installation

• Top class COP=4.06 (In case of 4HP cooling)

• 9 indoor units can be connected to 1 outdoor unit.

(In case of 6 HP)

• It is possible to perform cooling operation at outdoor temperatures down to -10˚C.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

ECOi 6 Series VRF

Electric VRF, ECOi

C0706DXH8 C0906DXH8

C1156DXH8 C1306DXH8

C1406DXH8 C1606DXH8

C1806DXH8

The ever-evolving SANYO ECOi VRF series

Hi COP Range

At start up stage a unit can have Hi COP function selected - this lowers the capacity and increases the COP. You have the choice.

• Extended range - Available from 8 to 20HP

• Hi COP units - Available from 10 to 16HP

• Up to 64 indoor unit connectablity -

Ideal for multiple small area conditioning such as hotels

System (HP)

Connectable indoor units

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60

13 16 19 23 26 29 33 36 40 43 47 50 53 56 59 64

High external static pressure

Special setting at site allows all models to provide up to 80Pa due to newly designed fan, fan motor and casing.

The flexible design requires an air discharge duct to avoid a reduction in performance due to shortcut of air circulation.

The new feature allows the outdoor unit to be installed inside plant rooms on any floor of the building.

Extended operating range

The heating operation range has been extended from -20°C to -25°C

Current 5 series

High static pressure - 80Pa

2 Way ECOi 6 series

-25 0 -20 0 -15 0 -10 0 -5 0 0 0 5 0 10 0 15

Heating, outside air temperature (

0 o

CWB)

20 0

Cooling operation range: -10°C DB to 43°C DB

Extended compressor life by uniform compressor operation times

The total operation time of the compressors is monitored by a microcomputer so that the operation times of all compressors in the same refrigerant system are balanced.

Compressors with shorter operation times are utilised first.

A, C: DC inverter compressor

B, D: Constant speed compressor

A B C D

50h 30h 60h 10h

Load increase

A B C D

Load increase

A B C D

Load increase

A B C D

10

Example: Time leveling of compressor operating hours

D

C

1

A

C

2

D A A

C C C

3 4 5

5

0

DC 1

AC

2

DC 3

AC

4

AC

5

Compressor

In the above graph the compressor drives from 3 - 5 - 2 - 4 - 1

Automatic back-up operation in compressors and units

The system benefits by having an automatic back-up feature in periods of maintenance and emergency situations.

Easy to design solutions for schools, hotels, hospitals and other large buildings

Difference between Max. and Min. length after first branch can be a maximum of 50m; larger pipe runs can be up to 180m.

Increased piping lengths and design flexibility

Actual piping length 150m to 180m

Max. piping length 300 to 1000m

Wider line-up

8-48HP 8-60HP

(27 system combinations)

System difference of elevation:

50 m *1

15 m

Actual lenght:

180 m

Difference in elevation between indoor units

*1: 40m if the outdoor unit is below the indoor unit.

MAX. 50m

Conventional model

6 Series

MAX. 180m

V4

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

V5

2 Way ECOi

Electric VRF, ECOi

Appearance

HP

Model Name (SPW-)

8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP

C0706DXH8 C0906DXH8 C1156DXH8 C1306DXH8 C1406DXH8 C1606DXH8 C1806DXH8 C1306DXH8 C1306DXH8 C1306DXH8 C1406DXH8 C1406DXH8

C0706DXH8 C0906DXH8 C1156DXH8 C1156DXH8 C1306DXH8

Power supply

Cooling capacity

Heating capacity

COP Cooling

COP Heating

Electric ratings

Running amperes

Cooling

Power input

Running amperes

Heating

Power input

Starting amperes

Dimensions(H*W*D)

Net weight

Air circulation

External static pressure

Refrigerant amount at shipment

Gas pipe

Piping connections

Liquid pipe

Balance pipe

Ambient temperature operating range

Sound pressure

Normal mode

Silent mode

Pa kg mm mm mm kW kW

22.4

25.0

28.0

31.5

33.5

37.5

380/400/415 3phase/ 50Hz

40.0 45.0

45.0 50.0

50.0

56.0

56.0

63.0

61.5

69.0

68.0

76.5

380/400/415 3phase/ 50Hz

73.0 78.5

81.5 87.5

85.0

95.0

W/W

W/W

4.05

4.57

3.60

4.10

3.61

4.10

3.62

4.21

3.35

3.86

3.49

3.88

3.33

3.81

3.60

4.10

3.61

4.10

3.61

4.16

3.62

4.21

3.48

4.02

A 9.0/8.5/8.2 12.6/12.0/11.5 15.1/14.3/13.8 17.9/17.0/16.4 21.8/20.7/19.9 23.2/22.1/21.3 27.2/25.9/24.9 28.1/26.7/25.7 30.6/29.0/28.0 33.0/31.3/30.2 35.2/33.4/32.2 39.6/37.7/36.3

kW 5.54

7.78

9.29

11.06

13.42

14.33

16.8

17.31

18.85

20.34

21.7

24.45

A 8.9/8.4/8.1

12.5/11.8/11.4 14.8/14.1/13.6 17.3/16.5/15.9 21.0/20.0/19.3 23.4/22.3/21.4 26.8/25.4/24.5 27.7/26.3/25.3 30.3/28.7/27.7 32.2/30.6/29.5 33.7/32.0/30.9 38.3/36.4/35.1

kW

A

5.48

1/1/1

7.68

9.15

10.7

12.97

14.45

16.52

17.07

18.66

19.84

20.8

23.63

mm 1758*770*930 1758*770*930 1758*770*930 1758*1000*930 1758*1000*930 1758*1540*930 1758*1540*930 1758*1830*930 1758*1830*930 1758*1830*930 1758*1830*930 1758*2060*930 kg 230 281 281 307 307 423 423 537 588 588 588 614 m

2

/min 147 153 190 212 212 244 283 358 365 402 402 424 dB(A) dB(A)

80

9,9

19.05

9.52

6.35

56.5

53.5

80

9,9

22.22

9.52

6.35

59.0

56.0

80

9,9

25.4

80

9,9

25.4

80

9,9

28.58

80

9,9

28.58

12.7

6.35

12.7

6.35

12.7

6.35

15.88

6.35

Cooling:-10 o

CDB~+43 o

CDB, Heating:-25 o

CWB~+15 o

CW B

61.0

58.0

62.0

59.0

62.0

59.0

60.0

57.0

80

9,9

28.58

15.88

6.35

63.0

60.0

80

9,9

28.58

15.88

6.35

63.0

60.0

80

9,9

28.58

63.5

60.5

80

9,9

31.75

80

9,9

31.75

80

9,9

31.75

15.88

6.35

19.05

6.35

19.05

6.35

19.05

6.35

Cooling:-10 o

CDB~+43 o

CDB, Heating:-25 o

CWB~+15 o

CW B

64.5

61.5

64.5

61.5

65.0

62.0

Data subject to final confirmation

Hi COP

C0706DXH8

C0906DXH8

C1156DXH8

Appearance

HP

Model Name (SPW-)

Power supply

Cooling capacity

Heating capacity

COP Cooling

COP Heating

Electric ratings

Cooling

Running amperes

Power input

Running amperes

Heating

Power input

Starting amperes

Refrigerant amount at shipment

Piping connections

Gas pipe

Liquid pipe

Balance pipe

Ambient temperature operating range

Normal mode

Sound pressure

Silent mode

10HP 12HP 14HP 16HP

C1306DXH8 C1406DXH8 C1606DXH8 C1806DXH8

Hi COP Setting

380/400/415 3phase/ 50Hz kW kW

W/W

28.0

31.5

4.06

35.5

37.5

4.07

40.0

45.0

4.01

45.0

50.0

3.88

W/W 4.45

4.45

4.41

4.39

A 11.2/10.7/10.3 13.4/12.7/12.2 16.3/15.4/14.9 18.9/17.9/17.3

kW 6.90

8.23

9.98

11.06

A 11.5/10.9/10.5 13.7/12/12.5 16.6/15.8/15.2 18.6/17.6/17.0

mm mm mm kW 7.08

A 74/77/80 kg 9,9

22.22

9.52

6.35

dB(A) dB(A)

8.43

78/81/85

9,9

25.4

12.7

6.35

10.2

89/92/95

9,9

25.4

12.7

6.35

11.4

95/98/101

9,9

28.58

12.7

6.35

Cooling:-10 o CDB~+43 o CDB, Heating:-25 o CWB~+20 o CW B

62.0

59.0

62.0

59.0

60.0

57.0

63.0

60.0

V6

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP 52HP 54HP 56HP 58HP 60HP

C1406DXH8 C1606DXH8 C1806DXH8 C1806DXH8 C1806DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1606DXH8 C1806DXH8 C1806DXH8 C1806DXH8 C1806DXH8 C1806DXH8

C1406DXH8 C1406DXH8 C1406DXH8 C1606DXH8 C1806DXH8 C1306DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1606DXH8 C1606DXH8 C1806DXH8 C1806DXH8

C1156DXH8 C1156DXH8 C1306DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1406DXH8 C1606DXH8 C1606DXH8 C1806DXH8

90.0

100.0

380/400/415 3phase/ 50Hz

96.0 101.0

108.0 113.0

107.0

119.0

113.0

127.0

118.0

132.0

124.0

138.0

130.0

145.0

135.0

380/400/415 3phase/ 50Hz

140.0 145.0

150.0 155.0 160.0

151.0

169.0

156.0

175.0

162.0

182.0

168.0

189.0

3.35

3.86

3.45

3.98

3.34

3.83

3.41

3.84

3.33

3.81

3.62

4.21

3.52

4.08

3.43

3.96

3.35

3.86

3.53

3.97

3.34

3.84

3.39

3.85

3.43

3.85

3.38

3.83

3.33

3.81

43.5/41.4/39.9 44.6/42.4/40.9 49.0/46.6/44.9 50.4/47.9/46.2 54.5/51.8/49.9 53.1/50.5/48.6 56.9/54.0/52.1 61.4/58.3/56.2 65.3/62.0/59.8 64.4/61.2/59.0 70.8/67.2/64.8 72.2/68.6/66.1 73.7/70.0/67.5 77.7/73.8/71.1 81.7/77.6/74.8

26.85

27.53

30.23

31.11

33.61

32.75

35.07

37.86

40.27

39.71

43.65

44.53

45.44

47.91

50.41

42.0/39.9/38.5 43.2/41.1/39.6 47.8/45.4/43.8 50.2/47.7/46.0 53.6/50.9/49.1 51.1/48.5/46.8 54.6/51.9/50.0 59.3/56.4/54.3 63.1/59.9/57.8 63.7/60.5/58.4 68.8/65.4/63.0 71.2/67.7/65.2 73.6/69.9/67.4 77.0/73.1/70.5 80.4/76.3/73.6

25.93

26.66

29.48

30.96

33.04

31.49

33.7

36.59

38.9

39.3

42.45

43.93

45.41

47.48

49.56

1758*2060*930 1758*2600*930 1758*2600*930 1758*3140*930 1758*3140*930 1758*2890*930 1758*2890*930 1758*3120*930 1758*3120*930 1758*3660*930 1758*3660*930 1758*4200*930

614 730 730 846 846 895 895 921 921 1,037 1,037 1,153

424 456 495 528 567 614 614 636 636 668 707 740

80

9,9

31.75

80

9,9

31.75

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

80

9,9

38.1

19.05

6.35

Cooling:-10 o

CDB~+43 o

CDB, Heating:-25 o

CWB~+15 o

CW B

65.0

62.0

19.05

6.35

64.0

61.0

19.05

6.35

65.5

62.5

19.05

6.35

65.0

62.0

19.05

6.35

66.0

63.0

19.05

6.35

66.5

63.5

19.05

6.35

19.05

6.35

19.05

6.35

19.05

6.35

Cooling:-10 o

CDB~+43 o

CDB, Heating:-25 o

CWB~+15 o

CW B

66.5

63.5

67.0

64.0

67.0

64.0

66.0

63.0

19.05

6.35

67.0

64.0

19.05

6.35

66.5

63.5

1,269

771

80

9,9

38.1

19.05

6.35

1758*4740*930

1,269

810

80

9,9

38.1

19.05

6.35

66.0

63.0

67.0

64.0

1,269

849

80

9,9

38.1

19.05

6.35

68.0

65.0

Data subject to final confirmation

C1306DXH8

C1406DXH8

C1606DXH8

C1806DXH8

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

V7

3 Way ECOi

Electric VRF, ECOi

C0705DZH8

C0905DZH8

C1155DZH8

C1305DZH8

C1405DZH8

ECOi 3 Way is one of the most advanced VRF systems available. Not only offering high-efficiency and performance for simultaneous heating and cooling, its sophisticated design makes installation and maintenance much easier.

• Simultaneous heating and cooling for total control

• Single footprint size for all unit capacities (8-16HP)

• DC inverter technology combined with R410A for excellent efficiency

• System configuration from 8HP to 48HP

• Diversity ratio 50-130%

• Increased outdoor fan’s static pressure valve

• Sound levels: from 54,5dB(A)

• Quiet mode offers a further 3dB(A) reduction

• Extended pipe runs of up to 150m

• COPs to 4,09

• Provides cooling down to -10°C ambient

• Connectability of 40 indoor units from 24HP upwards

• Improvement of energy efficiency in part load condition operation

• Compatibility with 3 way ECOi 4-series

Extended operating range - better output at lower temperatures

The operating range for heating has been extended to

-20°C. The remote controller temperature setting for heating operation has also been extended from 16°C to 30°C.

8HP ~ 48HP

Cooling: -10˚C DB ~ 43˚C DB

Heating: -20˚C WB ~ 15˚C WB

There is improved performance at lower ambient conditions due to SANYO’s unique wrap-around outdoor unit coil design and active defrost management.

L5

V8

Balance pipe

Piping design

(ø 9.52)

1. Main piping length LM = LA + LB···≤80 m

2. Main distribution pipes LC-LH are selected according to the capacity after the distribution joint.

3. Size of indoor unit connection piping 1-40 is determined by the connection piping size on the indoor units.

Symbol explanation

Distribution joint (APR, option)

Ball valve (BV, option)

Note: Do not use commercial T-pieces for the liquid pipes of and .

* Be sure to use R410A distribution joints for outdoor unit connections and piping branches.

H3

C

L2

B

LO

A

LM

LB LC LD

LA

LF

4

Within 400 mm

For extension

For extension

Within 400 mm

LH

1

LG

L4

5

LE

2 3

6 40

Solenoid Valve Kit

L1

H2

H1

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Ranges that apply to refrigerant piping lengths and to differences in installation heights

Items Marks Contents Length (m)

Allowable piping length

The No.1 distribution joint

L1

∆ L (L2–L4)

LM

1, 2~40

L1+1+2+~40+A+B+LF+LG+LH

L5

Max. piping length

Actual piping length

Equivalent piping length

Difference between the max. length and the min. length from the No. 1 distribution

Max. length of main piping (at max. diameter)

Max. length of each distribution

Total max. piping length including length of each distribution (only narrow tubing)

Distance between PC and AD unit

Allowable elevation difference

H1

H2

H3

When outdoor unit is installed higher than indoor unit

When outdoor unit is installed lower than indoor unit

Max. difference between indoor units

Max. difference between outdoor units

Note 1: The outdoor connection main piping (LO part) depends on the total capacity of the outdoor units connected to the end.

Note 2: When the main piping length (L1) (equivalent length) exceeds 90 m, increase the size of both the gas and liquid main piping (LM) by 1 step.

Specifications subject to change without notice.

Industry’s smallest changeover boxes - fewer siting problems

The SANYO solenoid valve kit is only 147mm high (without the removable bracket) and takes its power from the indoor unit, saving the cost of an additional supply.

• Individual indoor unit control in one SVK control box group

• No additional power supply required

• Single mounting fix point

• 2 sizes available

Fully-automatic simultaneous Cooling/Heating operation and heat recovery

≤300

≤10

≤50

≤40

≤15

≤4

≤150

≤175

≤40

≤80

≤30

ATK-RZP56BGWB

ATK-RZP160BGWB

Individual control

(ON/OFF, T set

, Fan, Flap, etc.)

At same operating mode

Extended compressor life by uniform compressor operation times

The total operation time of the compressors is monitored by a microcomputer, so that there is no unbalance for the operation times of all compressors in the same refrigerant system, and compressors with a shorter operation time are operated with preference. System example: A, C: DC inverter compressor

B, D: Constant speed compressor

A B

50

h

30

h

C D

60

h

10

h

Load increase

A B C D

Load increase

A B C D

Load increase

A B C D

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

V9

3 Way ECOi

Electric VRF, ECOi

Appearance

HP (Combined systems)

Model

8 10 12 14 16 18 20 22 24 26

C0705DZH8 C0905DZH8 C1155DZH8 C1305DZH8 C1405DZH8 8 C0705DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8

10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8

Power supply

Cooling capacity

Heating capacity

EER Cooling

COP Heating

Electric ratings

Cooling

Heating

Running current/AMPs

Power input

Running current/AMPs

Power input

Recommended fuse sizes (motor rated)

Dimensions (H/W/D)

Net weight

Airflow

Piping connection

Gas

Discharge

Liquid

Balance

Operating sound - normal mode

Operating sound - quiet mode

Maximum number of indoor units mm kg m

3

/min

Inches

Inches

Inches

Inches dB(A) dB(A) kW 22,40

380/400/415V-3phase/50Hz

28,00 33,50 40,00 45,00 50,40 kW kW

25,00

3,78

31,50

3,45

37,50

3,41

45,00

3,45

50,00

3,38

56,50

3,57 kW 4,09 3,95 3,81 3,91 3,79 4,01

A 10,0/9,5/9,2 13,7/13,0/12,6 16,6/15,7/15,2 20,0/19,0/18,3 23,0/21,8/21,0 23,8/22,6/21,8 kW 5,93 8,12 9,82 11,60 13,31 14,10

A 10,3/9,8/9,4 13,5/12,8/12,3 16,6/15,8/15,2 19,9/18,9/18,2 22,8/21,6/20,9 23,9/22,6/21,8 kW 6,11 7,97 9,84 11,50 13,20 14,10

32 32 32 40 40 32x2

290

150

3/4

5/8

54,5

51,5

13

3/8

290

160

7/8

55,0

52,0

16

1887x890x890 (+60)

290

180

350

200

1 1/8

3/4

1/2

3/8

56,0

53,0

19

60,0

57,0

23

7/8

350

220

61,0

58,0

26

580

150+160

57,8

54,8

29

380/400/415V-3phase/50Hz

56,00

63,00

3,46

3,96

27,3/26,0/25,0

16,20

26,8/25,5/24,6

15,90

32x2

58,0

55,0

33

61,50

69,00

3,44

3,88

30,2/28,7/27,7

17,90

30,0/28,5/27,5

17,80

32x2

1887x1880x890 (+60)

580

160+160

580

160+180

1 1/8

7/8

5/8

3/8

58,5

55,5

36

68,00

76,50

3,45

3,92

33,6/31,9/30,8

19,70

33,3/31,6/30,5

19,05

1x14

1x32

640

160+200

657,8

54,8

40

73,00

81,50

3,41

3,84

36,5/34,7/33,5

21,40

36,2/34,4/33,1

21,20

1x14

1x32

640

160+220

7/8

61,1

57,1

40

Data subject to final confirmation

System example

Outdoor unit

Concentration

Since all pipings are concentrated into one pipe shaft, you can minimise piping space and construction labour.

Connection

SANYO make it possible to link outdoor units together for a large capacity (48HP)

If indoor/outdoor units need servicing, a ball valve (optional) cuts off non-operational units to let other units stay running.

System limitations

Maximum number of combined outdoor units

Maximum HP of combined outdoor units

Maximum number of connectable indoor units

Indoor/outdoor unit capacity ratio

Maximum actual piping length

Maximum level difference (when outdoor unit is lower)

Maximum total piping length in one direction

3

48HP

40

50-130%

150m

50(40)m

300m

Solenoid valve kit

Indoor unit

Addition

If your indoor capacity load changes in the future, it’s easy to add on both indoor and outdoor units using the same pipings.

If the additional installment of outdoor and indoor units is expected, the size of refrigerant piping should be decided according to the total capacity after the addition.

V10

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

28 30

380/400/415V-3phase/50Hz

78,50 85,00

32

12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8

16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8

14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8

90,00

34

96,00

36

101,00

38

107,00

40 42

380/400/415V-3phase/50Hz

113,00 118,00

44

124,00

46

130,00

48

135,00

87,50

3,40

3,80

39,4/37,5/36,1

23,10

39,3/37,3/36,0

23,00

95,00

3,41

3,85

43,0/40,8/39,4

24,90

42,6/40,8/39,0

24,70

100,00

3,38

3,79

45,9/43,6/42,1

26,60

45,6/43,3/41,7

26,40

108,00

3,45

3,93

47,5/45,1/43,5

27,80

46,9/44,6/43,0

27,50

113,00

3,41

3,88

50,5/48,0/46,3

29,60

49,7/47,2/45,5

29,10

119,00

3,42

3,84

53,0/51,0/49,0

31,30

53,0/50,0/48,0

31,00

127,00

3,42

3,88

57,0/54,0/52,0

33,00

56,0/54,0/52,0

32,70

132,00

3,40

3,84

60,0/57,0/55,0

34,70

59,0/56,0/54,0

34,40

138,00

3,41

3,81

63,0/60,0/58,0

36,40

63,0/59,0/57,0

36,20

145,00

3,40

3,83

66,0/63,0/60,0

38,20

65,0/62,0/60,0

37,90

150,00

3,38

3,79

69,0/65,0/63,0

39,90

68,0/65,0/63,0

39,60

1x14

1x32

2x40 2x40

1887x1880x890 (+60)

640

180+220

1 3/8

700

200+220

3/4

3/8

60,4

57,4

40

1 1/8

61,0

58,0

40

700

220+220

61,5

58,5

40

2x32

1x40

2x32

1x40

2x32

2x40

1x32

2x40

1x32

2x40

1x32

2x40

1x40

1x32

1x40

1x32

1887x2870x890 (+60)

930 930 930 990 990 990 1050 1050

160+160+200 160+160+220 160+180+220 160+200+220 160+220+220 180+220+220 200+220+220 220+220+220

1 3/8 1 5/8

1 1/8 1 3/8

3/4

3/8

60,8

57,8

40

61,3

58,3

40

61,5

58,5

40

62,0

59,0

40

62,4

59,4

40

62,6

59,6

40

63,0

60,0

40

63,3

60,3

40

Data subject to final confirmation

Dimensions ECOi

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

V11

Mini ECOi

SPW-CR365GXH56B SPW-CR365GXH8B

SPW-CR485GXH56B SPW-CR485GXH8B

SPW-CR605GXH56B SPW-CR605GXH8B

SANYO’s ECOi Mini, the 2 pipe heat pump small VRF system, is specifically designed for the European market.

Offering between 11kW and 16kW cooling capacity in 3 sizes and up to 9 indoor units connected, the ECOi Mini sets standards of performance and flexibility.

Utilising R410A and DC inverter technology, SANYO offers VRF to a new and growing market.

Forming a new key part of the SANYO VRF line up, the ECOi

Mini is compatible with the same indoor units and controls as the rest of the electric and gas-powered range.

Features at a glance

• Single phase or three phase power supply

• One AMP start current

• DC inverter technology combined with R410A for

excellent efficiency

• COP of up to 4.34

• Diversity ratio 50-130%

• 150m pipe runs

• Cooling operation to -10°C

• Full range of indoor units and control options

• Compact outdoor unit 1230x940x340mm

Wide operating range

The operating range for heating operation is to -20°C, the cooling range is to -10°C. The remote controller temperature setting offers a range from 16°C to 30°C.

8HP ~ 48HP

Cooling: -10˚C DB ~ 43˚C DB

Heating: -20˚C WB ~ 15˚C WB

Installation possible even in narrow space

Up to 9 indoor units per system

Highest COPs - lowest running costs

HP

EER Cooling

COP Heating

4

4.06

4.34

5

3.66

4.10

6

3.39

3.84

V12

Electric VRF, ECOi

Note: Do not use commercially available

T-joints for the liquid tubing.

Be sure to use special R410A distribution joints (APR: purchased separately) for outdoor unit connections and tubing branches.

R410A distribution joint

APR-P160BG (for indoor unit)

HP

Model name

Power supply

Cooling capacity

Heating capacity

EER cooling

COP heating

Electric rating

Cooling

Heating

Running current/AMPs

Power input

Running current/AMPs

Power input

Recommended fuse size (motor rated)

Dimensions (H/W/D)

Net weight

Air circulation

Refrigerant amount at shipment

Piping connection

Gas

Liquid

Operating sound normal mode

Quiet mode

Maximum number of indoor units kW kW mm kg m 3 /min kg

Inches

Inches dB(A) dB(A)

A kW

A kW

4

SPW-CR365GXH56B/SPW-CR365GXH8B

16

11,20

12,50

4,06

4,34

14,1/4,34

2,76

14,7/4,52

2,88

5/8

3/8

51,0

48,0

6

16

5 6

SPW-CR485GXH56B/SPW-CR485GXH8B

230V, 1 phase, 50/60Hz/400, 3 phase, 50/60Hz

14,00

16,00

3,66

4,10

19,6/6,02

3,83

19,9/6,13

3,90

16 16

1230x940x340

104

100

3,5

5/8

3/8

51,0

48,0

8

SPW-CR605GXH56B/SPW-CR605GXH8B

16

15,50

17,60

3,39

3,84

23,4/7,18

4,57

23,4/7,19

4,58

16

3/4

3/8

52,0

49,0

9

Specifications subject to change without notice.

Ranges that apply to refrigerant piping lengths and to differences in installation heights

Items

Allowable piping length

Allowable elevation difference

L = Length, H = Height

Marks

L1

∆ L (L2–L3)

1, 2~ n

1+ 2+~ n-1+L1

H1

H2

Contents

Max. piping length

Difference between the max. length and the min. length from the No. 1 distribution joint

Max. length of each distribution tube

Total max. piping length including length of each distribution (only narrow tubing)

When outdoor unit is installed higher than indoor unit

When outdoor unit is installed lower than indoor unit

Max. difference between indoor units

Length (m)

Actual piping length

Equivalent piping length

≤150

≤175

≤40

≤30

≤200

≤50

≤40

≤15

Specifications subject to change without notice.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

V13

VRF Indoor Unit Range

Wide choice of models depending on the indoor requirements

Electric VRF, ECOi

Model size

Capacity kW

Capacity BTU/h

X type

Semi Concealed Cassette

XM type

Semi Concealed

LDR type

Semi Concealed

Slim Cassette

DR type

Concealed Duct

25,48 type

Cooling

Heating

Cooling

Heating

76,96 type

US type

Concealed Duct

U type

Concealed Duct

FTR type

Floor/Ceiling Mounted Units

T type

Ceiling Mounted Unit

K type

Wall Mounted Unit

KR type

Wall Mounted Unit

FR type

Floor Standing Unit

FMR type

Concealed Floor Standing Unit

GU type

Total Heat Exchanger

7

2,2

2,5

7500

8500

SPW-X075XH

Panel

PNR-XD484GHAB

SPW-XM075XH

Panel

PNR-XM185

SPW-US075XH

SPW-U075XH

SPW-FTR74EXH56B

SPW-K075XH

SPW-KR74GXH56B

SPW-FR74GXH56B

9

2,8

3,2

9600

11000

SPW-X095XH

Panel

PNR-XD484GHAB

SPW-XM095XH

Panel

PNR-XM185

12

3,6

4,2

12000

14000

SPW-X125XH

Panel

PNR-XD484GHAB

SPW-XM125XH

Panel

PNR-XM185

16

4,5

5,0

15000

17000

SPW-X165XH

Panel

PNR-XD484GHAB

SPW-XM165XH

Panel

PNR-XM185

18

5,6

6,3

19000

21000

SPW-X185XH

Panel

PNR-XD484GHAB

SPW-XM185XH

Panel

PNR-XM185

SPW-LDR94GXH56B

Panel

PNR-LD254GHAB

SPW-LDR124GXH56B

Panel

PNR-LD254GHAB

SPW-LDR164GXH56B

Panel

PNR-LD254GHAB

SPW-LDR184GXH56B

Panel

PNR-LD254GHAB

SPW-US095XH

SPW-U095XH

SPW-K095XH

SPW-KR94GXH56B

SPW-FR94GXH56B

SPW-US125XH

SPW-U125XH

SPW-T125XH

SPW-K125XH

SPW-US165XH

SPW-U165XH

SPW-US185XH

SPW-U185XH

SPW-FMR74GXH56B SPW-FMR94GXH56B SPW-FMR124GXH56B SPW-FMR164GXH56B SPW-FMR184GXH56B

SPW-GU055XH

22

6,4

7,0

22000

24000

SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56B SPW-FTR224EXH56B

SPW-T165XH

SPW-KR124GXH56B SPW-KR164GXH56B SPW-KR184GXH56B

SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B

SPW-GU075XH

SPW-T185XH

SPW-GU105XH

25

7,3

8,0

25000

27000

SPW-X255XH

Panel

PNR-XD484GHAB

SPW-LDR254GXH56B

Panel

PNR-LD254GHAB

SPW-DR254GXH56B

SPW-U255XH

SPW-T255XH

SPW-KR254GXH56B

SPW-FR254GXH56B

SPW-FMR254GXH56B

CFR type

Heat Recovery Units (page A29-A30)

36

10,6

11,4

36000

39000

SPW-X365XH

Panel

PNR-XD484GHAB

48

14,0

16,0

47800

54600

SPW-X485XH

Panel

PNR-XD484GHAB

60

16,0

18,0

54600

61500

SPW-X605XH

Panel

PNR-XD484GHAB

SPW-DR364GXH56B SPW-DR484GXH56B

SPW-U365XH

SPW-T365XH

SPW-U485XH

SPW-T485XH

SPW-U605XH

76

22,4

25,0

76400

85300

96

28,0

31,5

95500

107500

SPW-DR764GXH56B SPW-DR964GXH56B

Wireless remote control

Type with built-in sensor part

Type with separately installed sensor part

Functions

A1

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Wider operation Comfortable auto-flap control

Self-diagnosing function

Automatic restart function for power failure

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Automatic fan operation

Air Sweep Mild dry Built-in drain pump

A2

X type

semi concealed cassette

SPW-X075XH SPW-X095XH

SPW-X125XH SPW-X165XH

SPW-X185XH SPW-X255XH

SPW-X365XH SPW-X485XH

SPW-X605XH

The award winning range of X type cassettes are smaller, shallower and lighter than previous models and feature a 950 x 950mm panel throughout. The DC fan motor and air discharge louvre ensure quiet, optimum air distribution.

• Compact design

• Reduced sound levels (from previous models)

• DC fan motor for increased efficiency

• Powerful drain pump gives 850mm lift

• Lightweight design

• Fresh air knockout

• Branch duct connection

Drain Pump of about 850 mm from the ceiling surface

A3

The flap can be removed easily for washing with water.

Lighter and thinner, easier installation!

The top class lightest weight with 26 kg (for type

36~60), body height only 256 mm (7~25), so that installation is possible even in narrow ceilings.

Easy fine adjustment of the body suspension height!

The four corners of the ceiling panel have adopted removable corner pockets.

 Even after installation, fine adjustment of the suspension height is possible easily by removing the corner pockets.

Light, thin, and attractive design with easy installation

The direction of the air intake grille can be changed. A wireless remote control light receiver can be installed by changing the corner cover. The installation can be done in a short time.

Easy servicing of the drain pan

A large-diameter (45 mm) drain pan inspection port has been provided, and drain pan and drain pump can be cleaned easily.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Air intake chamber Panel

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

CMB-FS140AGB

Air intake plenum

CMB-GS140AG

Air intake box

Both Air intake plenum and

Air intake box are necessary

PNR-XD484GHAB

RCS-TM80BG

RCS-SH80BG.WL

RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Pipe connections

Cooling

Heating

Cooling

Heating

Type

Fan motor Airflow rate (H/M/L) m³/min

Output kW

Power sound level (H/M/L) dB(A)

Sound pressure sound (H/M/L)

Height

Dimensions Width

Depth dB(A) mm mm mm

Liquid

Gas

Drain piping inches mm inches mm kW

BTU/h kW

BTU/h kW kW

A

A

Net weight kg

SPW-X075XH SPW-X095XH SPW-X125XH SPW-X165XH SPW-X185XH SPW-X255XH SPW-X365XH SPW-X485XH SPW-X605XH

2,2

7500

2,5

8500

2,8

9600

3,2

11000

0,033/0,032/0,032

0,023/0,022/0,022

0,22/0,21/0,20

0,19/0,18/0,17

3,6

12000

4,2

14000

15,5/14/13

0,05

42/40/38

31/29/27

256 + <35>

4,5

220/230/240V, 1 phase - 50, 60 Hz

5,6 7,3

15000

5,0

19000

6,3

25000

8,0

0,23/0,22/0,21

0,20/0,19/0,18

Turbo fan

10,6

36000

11,4

14

47800

16,0

16

54600

18,0

17000 21000 27000 39000 54600 61400

0,033/0,032/0,032 0,035/0,034/0,034 0,042/0,041/0,041 0,070/0,069/0,069 0,099/0,097/0,097 0,107/0,105/0,105

0,023/0,022/0,022 0,023/0,023/0,023 0,031/0,031/0,031 0,062/0,060/0,060 0,095/0,093/0,093 0,100/0,098/0,098

0,22/0,21/0,20

0,19/0,18/0,17

0,29/0,27/0,26

0,26/0,25/0,24

0,49/0,46/0,44

0,48/0,45/0,43

0,67/0,63/0,60

0,67/0,63/0,60

0,72/0,68/0,65

0,76/0,71/0,68

16/14/13 20/16/14

45/42/39

34/31/28

28/23/21

50/47/44

39/36/33

33/25/22

0,09

53/49/45

42/38/34

319 + <35>

34/27/23

55/51/47

44/40/36

840 <950>

840 <950>

1/4 (ø6.35)

1/2 (ø12.7)

21+ <4,5>

The values in < > for external dimensions and Net weight are the values for the optional ceiling panel.

VP-25

3/8 (ø9.52)

5/8 (ø15.88)

26 + <4,5>

Specifications subject to change without notice.

R410A

A4

XM type

mini semi concealed cassette

SPW-XM075XH

SPW-XM095XH

SPW-XM125XH

SPW-XM165XH

SPW-XM185XH

Designed to fit exactly into a 600x600mm ceiling grid without the need to alter the bar configuration, the XM is ideal for small commercial and retrofit applications. In addition, the improvements to efficiency make this one of the most advanced units in the industry.

• Mini cassette fits into a 600x600mm ceiling grid

• Fresh air knock out

• Multidirectional air flow

• Anti-mould and anti-bacteria washable filters

• Powerful drain pump gives 850mm lift

• Turbo fans and heat exchanger fins with improved design

• DC fan motors with variable speed, new heat exchangers, etc. ensure an efficient power consumption

Special designed flap

The flap can be removed easily for washing.

Lighter and slimmer, easier installation

A lightweight unit at 26 kg (for type 36-60), the unit is also very slim with a height of only 281 mm, making installation possible even in narrow ceilings.

Up to 281 mm

A drain height of approx. 850 mm from the ceiling surface

The drain height can be increased by approximately 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible.

Up to 300 mm

Up to 850 mm

Panel

PNR-XM185

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG

Electric VRF, ECOi

RCS-XM18BG.WL

RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

SPW-XM075XH SPW-XM095XH

Cooling capacity

Heating capacity

Power input

Running amperes

Cooling

Heating

Cooling

Heating

Type kW

BTU/h kW

BTU/h kW kW

A

A

Fan motor Airflow rate (H/M/L) m³/min

Output kW

Power sound level (H/M/L) dB(A)

Pressure sound level (H/M/L)

Height

Dimensions Width dB(A) mm mm

2,2

7500

2,5

8500

0,034/0,031/0,030

0,024/0,021/0,020

0,26/0,23/0,21

0,24/0,21/0,19

Pipe connections

Depth

Liquid

Gas mm inches mm inches mm

Drain piping

Net weight kg

Heating: Indoor air temperature 20°C DB, outdoor air temperature 7°C DB/6°C WB.

9/8/7

41/38/36

30/27/25

2,8

9600

3,2

11000

SPW-XM125XH

220/230/240V, 1 phase - 50, 60Hz

3,6

12000

4,2

14000

0,037/0,034/0,031

0,027/0,024/0,021

0,29/0,26/0,23

0,27/0,24/0,21

Centrifugal fan

10/9/8

0.030

43/40/37

32/29/26

283

575 <625>

575 <625>

1/4 (ø6.35)

1/2 (ø12.7)

VP-20

19 + <2,7>

SPW-XM165XH

4,7

15000

5,0

17000

0,044/0,040/0,037

0,034/0,030/0,027

0,37/0,33/0,29

0,35/0,31/0,27

12/11/10

47/43/39

36/32/28

SPW-XM185XH

5,6

19000

6,3

21000

0,055/0,049/0,040

0,045/0,039/0,030

0,47/0,42/0,33

0,45/0,40/0,31

14/13/11

52/48/44

41/37/33

Specifications subject to change without notice.

A5

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A6

LDR type

semi concealed slim cassette

SPW-LDR94GXH56B

SPW-LDR124GXH56B

SPW-LDR164GXH56B

SPW-LDR184GXH56B

SPW-LDR254GXH56B

Designed for installation within the ceiling void, the LDR range of slimline 1 way blow cassettes feature powerful yet quiet fans for up to 4.2 metres.

Panel

PNR-LD254GHAB

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller

(Transmitter, common part)

RCS-TM80BG

Simplified remote controller

RCS-TRP80BG.WL

RCS-BH80BG.WL

RCS-KR1EG

• Ultra-Slim

• Suitable for standard and high ceilings

• Built-in drain pump provides 747mm lift

• Easy to install and maintain

• Hanging height can be easily adjusted

• Uses a DC fan motor to improve energy-efficiency

A7

Drain height

300mm or less

850mm or less

With 3 types of air-blow systems, the units can be used in various ways.

(1) One-direction down-blow system

Powerful one-direction “downblow” system reaches the floor even from high ceilings (up to

4.2m).

(2) Two-direction ceilingmounted system

“Down-blow” and “front-blow” systems are combined in a ceilingmounted unit to blow air over a wide area.

(3) One-direction ceiling-mounted system

This powerful ceiling-mounted

“front-blow” system efficiently air-conditions the space in front of the unit.

(Additional accessories required)

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Indoor unit specifications

Model Name SPW-LDR94GXH56B SPW-LDR124GXH56B SPW-LDR164GXH56B SPW-LDR184GXH56B SPW-LDR254GXH56B

Power source

Cooling capacity

Heating capacity

Power input

Cooling

Heating

Running amperes

Cooling

Heating

Type

Fan motor

Airflow rate (H/M/L) m³min

Output kW

Power sound level (H/M/L) dB(A)

A

A kW

BTU/h kW

BTU/h kW kW

Pressure sound level (H/M/L)

Height

Dimensions Width

Depth

Pipe connections

Liquid

Gas

Drain piping dB(A) mm mm mm inches mm inches mm

2,8

9600

3,2

11000

0,105/0,110/0,115

0,075/0,080/0,085

0,50/0,50/0,51

0,36/0,37/0,38

12/10/9

47/45/44

36/34/33

3,6

12000

4,2

14000

0,105/0,110/0,115

0,075/0,080/0,085

0,50/0,50/0,51

0,36/0,37/0,38

Net weight kg

The values in < > for external dimensions and Net weight are the values for the optional ceiling panel.

220/230/240V, 1 phase - 50, 60 Hz

4,5

15000

5,0

17000

0,105/0,110/0,115

0,075/0,080/0,085

0,50/0,50/0,51

0,36/0,37/0,38

Sirocco fan

12/11/10

0,05

47/46/45

36/35/34

200 + <20>

1000 <1230>

710 <800>

1/4 (ø6.35)

1/2 (ø12.7)

21 + <5,5>

VP-25

5,6

19000

6,3

21000

0,110/0,115/0,120

0,080/0,085/0,090

0,53/0,53/0,54

0,38/0,39/0,40

13/11,5/10

49/47/45

38/36/34

7,3

25000

8,0

27000

0,115/0,120/0,125

0,085/0,090/0,095

0,55/0,55/0,56

0,40/0,41/0,42

18/15/13

56/51/47

45/40/36

3/8 (ø9.52)

5/8 (ø15.88)

22 + <5,5>

Specifications subject to change without notice.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A8

DR type

concealed duct high-static pressure

SPW-DR254GXH56B

SPW-DR364GXH56B

SPW-DR484GXH56B

SPW-DR764GXH56B

SPW-DR964GXH56B

The DR range of ducted units offers improved design flexibility for extended duct layouts as a result of their increased external static pressures.

• Complete flexibility for ductwork design

• Can be located into a weatherproof housing for external siting

• Air off sensor avoids cold air dumping

• Configurable air temperature control

System example

An inspection port (450 x 450mm or more) is required at the lower side of the indoor unit body (field supply).

Inspection port (450 x 450mm or more)

Rap valve kit

The types 76 and 96 require two rap valve kits for each unit.

(not required on a 1:1 installation)

ATK-RX160AGB

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Fan motor

Airflow rate (H/M/L) m³/min

Output kW

External static pressure Pa

Power sound level (H/M/L)

Pressure sound level (H/M/L)

Dimensions

Height

Width dB(A) dB(A) mm mm

Pipe connections

Cooling

Heating

Cooling

Heating

Type

Depth

Liquid

Gas

Drain piping kW

BTU/h kW

BTU/h kW kW

A

A mm inches mm inches mm

Net weight kg

SPW-DR254GXH56B SPW-DR364GXH56B SPW-DR484GXH56B SPW-DR764GXH56B SPW-DR964GXH56B

7,3

25000

8,0

27000

0,480/0,505/0,530

0,480/0,505/0,530

2,29/2,30/2,31

2,29/2,30/2,31

23/22/21

186

55/54/53

44/43/42

47

0,2

420

220/230/240V, 1 phase - 50, 60 Hz

10,6 14,0

36000

11,4

39000

0,520/0,545/0,570

0,520/0,545/0,570

2,46/2,46/2,47

2,46/2,46/2,47

30/28/25

176

56/55/53

45/44/42

1065

620

5/8 (ø15.88)

50

47800

16,0

54600

0,600/0,660/0,710

0,600/0,660/0,710

2,80/2,90/3,00

2,80/2,90/3,00

Sirocco fan

36/35/33

0,35

167

58/57/55

47/46/44

450

3/8 (ø9.52)

VP-25

54

22,4

76400

25,0

85300

0,870/0,900/0,930

0,870/0,900/0,930

4,05/4,06/4,07

4,05/4,06/4,07

56/53,1/49,6

0,2*2

176

59/58/57

48/47/46

3/4 (ø19.05)

110

467

1428

1230

220/230/240, 1ph - 50Hz

28,0

95500

31,5

107500

1,270/1,330/1,390

1,270/1,330/1,390

6,04/6,06/6,07

6,04/6,06/6,07

72/70/66

0,4*2

216

62/61/60

51/50/49

7/8 (ø22.22)

120

Specifications subject to change without notice.

A9

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A10

US type

concealed duct

SPW-US075XH

SPW-US095XH

SPW-US125XH

SPW-US165XH

SPW-US185XH

The ultra slim US type is one of the leading products of its type in the industry. With a depth of only

200mm it provides greater flexibility and can be used in far more applications.

In addition, its high-efficiency and extremely quiet sound levels make it very popular with many users, including hotels and small offices.

• Ultra-slim profile: 200 mm for all models

• DC fan motor greatly reduces power consumption

• Ideal for hotel application with very narrow false ceilings

• Anti-mould washable filters included

• Easy maintenance and service by external electrical box

• 40 pa static pressure enables ductwork to be fitted.

• Includes drain pump

Ultra-slim profile for all models

200mm

Drain pump with increased power!

By adoption of a high-lift drain pump, the drain piping rise height can be increased to 785mm from the lower surface of the body.

Up to 300mm

Up to

500mm

285mm

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Fan motor

Airflow rate (H/M/L) m³/min

Output kW

External static pressure Pa

Power sound level (H/M/L)

Pressure sound level (H/M/L)

Dimensions

Height

Width dB(A) dB(A) mm mm

Pipe connections

Cooling

Heating

Cooling

Heating

Type

Depth

Liquid

Gas

Drain piping kW

BTU/h kW

BTU/h kW kW

A

A mm inches mm inches mm

Net weight kg

SPW-US075XH

2,2

7500

2,5

8500

0,036/0,036/0,036

0,026/0,026/0,026

0,26/0,26/0,26

0,23/0,23/0,23

8/7/6

10-30

43/42/40

28/27/25

SPW-US095XH

2,8

9600

3,2

11000

0,040/0,040/0,040

0,030/0,030/0,030

0,30/0,30/0,30

0,27/0,27/0,27

8,5/7,5/6,5

SPW-US125XH

220/230/240V, 1 phase - 50, 60Hz

3,6

12000

4,2

14000

0,042/0,042/0,042

0,032/0,032/0,032

0,31/0,31/0,31

0,28/0,28/0,28

Sirocco fan

9/8/7

0.05

SPW-US165XH

4,5

15000

5,0

17000

0,049/0,049/0,049

0,039/0,039/0,039

0,37/0,37/0,37

0,34/0,34/0,34

10,5/9,5/8

15-30

45/44/42

30/29/27

15-40

49/47/45

34/32/30

47/45/43

32/30/28

200

750

640

1/4 (ø6.35)

1/2 (ø12.7)

VP-20

19

SPW-US185XH

5,6

19000

6,3

21000

0,064/0,064/0,064

0,054/0,054/0,054

0,48/0,48/0,48

0,45/0,45/0,45

12,5/11,5/10

52/50/48

35/33/31

Specifications subject to change without notice.

A11

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A12

U type

concealed duct

SPW-U075XH SPW-U095XH

SPW-U125XH SPW-U165XH

SPW-U185XH SPW-U255XH

SPW-U365XH SPW-U485XH

SPW-U605XH

The U type ducted systems are the ideal solution for flexible, concealed air conditioning and the standard 200mm spigots ensure simple, hassle-free connection to spiral ductwork. The external static pressure can be increased via an optional booster cable to provide increased design flexibility.

• Industry leading low sound levels from 22 dB(A)

• Built-in drain pump provides 785mm lift

• Easy to install and maintain

• Air off sensor avoids cold air dumping

• Configurable air temperature control

Lowest noise levels in the industry.

The static pressure outside the unit can be increased.

By using the booster cable, the static pressure outside the unit can be increased.

type

standard with booster cable use

(Pa)

7-9-12

49

69

16-18

40

62

25

50

92

36

79

122

48-60

78

113

More powerful drain pump

By adoption of a high-lift drain pump, the drain piping rise height can be increased to 785mm from the lower surface of the body.

Up to 300mm

Up to

500mm

285mm

Unified body height of approximately 310 mm for all models

Even models with different capacities can be installed smoothly in the ceiling.

External electrical equipment box makes maintenance easy

Flexible air distribution is achieved by discharge grilles

A13

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

System examples

An inspection port (450 x 450mm or more) is required at the lower side of the indoor unit body.

7-22°C Air off temperature control as standard

• Able to control air off temperature

• Reduces cold drafts

• Accurate room temperature controls

23°C

12°C

Coil sensor

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Cooling

Heating

Running amperes

Cooling

Heating

Type

Airflow rate (H/M/L) m³/min

A

A

Fan motor

Output kW

External static pressure Pa

Power sound level (H/M/L) dB(A) kW

BTU/h kW

BTU/h kW kW

SPW-U075XH SPW-U095XH SPW-U125XH SPW-U165XH SPW-U185XH SPW-U255XH SPW-U365XH SPW-U485XH SPW-U605XH

220/230/240V, 1 phase - 50, 60 Hz

2,2

7500

2,5

8500

2,8

9600

3,2

11000

0,094/0,100/0,106

0,082/0,088/0,094

0,45/0,46/0,47

0,40/0,41/0,42

10/8,5/7

3,6

12000

4,2

14000

0,05

49(69)

40/37/33

(32)/29/26/22 Pressure sound level (H/M/L)

Height

Dimensions Width dB(A) mm mm 700

Pipe connections

Depth

Liquid

Gas mm inches mm inches mm

1/4 (ø6.35)

1/2 (ø12.7)

Drain piping

Net weight kg 24

The values in ( ) for the external static pressure and operating sound are for use of booster cable.

4,5

15000

5,0

5,6

19000

6,3

17000 21000

0,096/0,102/0,109

0,084/0,090/0,097

0,44/0,45/0,46

0,39/0,40/0,41

Sirocco fan

12/10,5/9

40(62)

41/39/36

(33)/30/28/25

25

310

630

VP-25

7,3

25000

8,0

27000

0,180/0,195/0,210 0,312/0,327/0,342

0,168/0,183/0,198 0,300/0,315/0,330

0,83/0,86/0,89 1,44/1,45/1,46

0,78/0,81/0,84 1,39/1,40/1,41

18/15/13

0,07

50(92)

45/41/38

1000

32

10,6

36000

11,4

39000

30/26/21

79(122)

49/44/42

(38)/34/30/27 (42)/38/33/31

3/8 (ø9.52)

5/8 (ø15.88)

14,0

47800

16,0

54600

0,14

33/30/25

78(113)

51/48/44

(44)/40/37/33

16,0

54600

18,0

0,308/0,325/0,341

0,296/0,313/0,329

1480

47

61500

1,42/1,43/1,44

1,36/1,37/1,38

Specifications subject to change without notice.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A14

FTR type

floor/ceiling mounted

SPW-FTR74EXH56B

SPW-FTR94EXH56B

SPW-FTR124EXH56B

SPW-FTR164EXH56B

SPW-FTR184EXH56B

SPW-FTR224EXH56B

The FTR type units offer the flexibility of floor or ceiling application without the need for further modification at installation stage.

• 3 speed centrifugal fan

• Anti-mould and anti-bacterial washable filters

• Horizontal flap swinging or set on a fixed position

• Shallow design

• Easy to install

Further comfort improvement with airflow distribution.

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TH80AG.WLB

RCS-TM80BG RCS-BH80AG.WLB

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Cooling

Heating

Cooling

Heating

Type

Fan motor Airflow rate (H/M/L) m³/min

Output kW

Power sound level (H/M/L) dB(A)

Pressure sound level (H/M/L)

Height

Dimensions

Pipe connections

Net weight

Width

Depth

Liquid

Gas

Drain piping dB(A) mm mm mm inches mm inches mm kg kW

BTU/h kW

BTU/h kW kW

A

A

SPW-FTR74EXH56B SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56B SPW-FTR224EXH56B

2,2

7500

2,5

8500

2,8

9600

3,2

11000

0,65/0,65/0,65

0,65/0,65/0,65

0,29/0,29/0,29

0,29/0,29/0,29

220/230/240V, 1 phase-50 Hz

3,6 4,5

12000

4,2

15000

5,0

14000 17000

5,6

19000

6,3

21000

0,88/0,88/0,88

0,88/0,88/0,88

0,41/0,41/0,41

0,41/0,41/0,41

6,4

22000

7,0

24000

Sirocco fan

10,5/9/7,5

0,07

60/54/49

49/43/38

12/10,8/9,7

62/58/54

51/47/43

0,09

15/13,5/12

63/60/57

52/49/46

680

900

190

1/4 (ø6.35)

1/2 (ø12.7)

VP-26

23,5

Specifications subject to change without notice. floor or ceiling application

A15

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A16

T type

ceiling mounted

SPW-T125XH

SPW-T165XH

SPW-T185XH

SPW-T255XH

SPW-T365XH

SPW-T485XH

The T type ceiling mounted unit feature a

DC fan motor for increased efficiency and reduced operating sound levels. All the units are the same height and depth for a uniform appearance in mixed installations and feature a fresh air knockout for improved air quality.

• Low sound levels

• New design, all units just 210mm high

• Large and wide air distribution

• Easy to install and maintain

• Fresh air knockout

A17

Further comfort improvement

The wide air discharge opening widens the air flow to the left and the right, so that a comfortable temperature is obtained in the entire room. The unpleasant feeling caused when the air flow directly hits the human body is prevented by the “Draft prevention position”, which changes the swing width, so that the degree of comfort is increased.

4 m

Correspondence to ceiling heights up to 4 m

Air distribution is automatically altered depending on the operational mode of the unit.

F1

F2

F3

F4

60°

F5

Heating: F1 to F3

Cooling: F1 to F3

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TRP80BG.WL

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Pipe connections

Cooling

Heating

Cooling

Heating

Type

Fan motor Airflow rate (H/M/L)

Output

Power sound level (H/M/L)

Pressure sound level (H/M/L)

Height

Dimensions Width

Depth

Liquid

Gas

Drain piping

Net weight m³/min kW dB(A) dB(A) mm mm mm inches mm inches mm kg kW

BTU/h kW

BTU/h kW kW

A

A

SPW-T125XH

3,6

12000

4,2

14000

0,028/0,029/0,029

0,028/0,029/0,029

0,26/0,24/0,23

0,26/0,24/0,23

12/10/9,0

46/43/41

35/32/30

SPW-T165XH SPW-T185XH SPW-T255XH

4,5

15000

5,0

17000

0,039/0,029/0,028

0,029/0,029/0,028

0,26/0,24/0,23

0,26/0,24/0,23

0,03

220/230/240V, 1 phase - 50, 60 Hz

5,6 7,3

19000

6,3

21000

0,031/0,032/0,032

0,031/0,032/0,032

25000

8,0

27000

0,043/0,043/0,044

0,042/0,042/0,043

13/11/9,0

47/44/41

36/33/30

0,28/0,26/0,24

0,28/0,26/0,25

Sirocco fan

0,38/0,35/0,33

0,38/0,35/0,34

18,5/15/14

0,04

49/47/44

38/36/33

210

910 1180

680

1/4 (ø6.35)

1/2 (ø12.7)

VP-20

21 25

SPW-T365XH

10,6

36000

11,4

39000

0,073/0,074/0,075

0,072/0,073/0,074

0,62/0,57/0,53

0,62/0,57/0,55

27,5/23/20

52/49/46

41/38/35

3/8 (ø9.52)

5/8 (ø15.88)

0,08

1595

SPW-T485XH

14,0

47800

16,0

54600

0,085/0,086/0,088

0,084/0,085/0,086

0,69/0,63/0,60

0,69/0,63/0,62

30/26/22

54/51/48

43/40/37

33

Specifications subject to change without notice.

R410A

A18

K type

wall mounted

SPW-K075XH

SPW-K095XH

SPW-K125XH

The K Type wall mounted unit has a stylish smooth panel which not only looks good but is also easy to clean.

The unit is also smaller, lighter and substantially quieter than previous models making it ideal for small offices and other commercial applications.

Closed discharge port

When the unit is turned off, the flap closes completely to prevent entry of dust into the unit and to keep the equipment clean.

Washable front panel

The indoor unit’s front panel can be easily removed and washed for trouble-free cleaning.

Lighter and smaller units make the installation easy

The width has been decreased by 17% and the units are lighter.

NEW

255mm

(Current

285mm)

NEW

825 mm

(Current 995mm)

Quiet operation

These units are among the quietest in the industry, making them ideal for hotels and hospitals.

Air distribution is automatically altered depending on the operational mode of the unit

F1

F2

F3

90°

F4 F5

Heating: F1 to F5

Cooling: F1 to F3

Anti-mould filters are standard

Smooth and durable design

The smooth cover means these units match most modern interiors. Their compact size enables them to blend in, even in small spaces.

Piping outlet in three directions

Piping outlet is possible in the three directions of rear, right, and left, making the installation work easier.

A19

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-SH1BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Indoor Unit

Power Source

Cooling capacity

Heating capacity

Power input

Cooling

Heating

Running amperes

Cooling

Heating

Power sound level (H/M/L)

Sound pressure level (H/M/L)

Fan motor

Air circulation (H/M/L)

Dimensions (HxWxD)

Type

Airflow rate (H/M/L)

Output

Pipe connections

Liquid

Gas

Drain piping

Net weight m

3

/min kW m 3 /hr mm inches mm inches mm kg kW

BTU/h kW

BTU/h kW kW

A

A dB(A) dB(A)

SPW-K075XH

2,20

7500

2,50

8500

540/450/360

285x825x217

0,018/0,019/0,019

0,019/0,019/0,020

0,16/0,16/0,16

0,17/0,17/0,18

46/43/39

35/32/28

SPW-K095XH

220/230/240V, 1 phase - 50, 60Hz

2,80

9600

3,20

11000

Sirocco fan

9/7,5/6

0,047

540/450/360

285x825x217

1/4 (ø6.35)

1/2 (ø12.7)

VP-13

10

SPW-K125XH

3,60

12000

4,20

14000

0,020/0,021/0,022

0,021/0,022/0,022

0,19/0,19/0,20

0,20/0,20/0,20

48/44/40

37/33/29

10/8,5/6,5

600/510/390

285x825x217

Specifications subject to change without notice.

R410A

A20

KR type

wall mounted

SPW-KR74GXH56B

SPW-KR94GXH56B

SPW-KR124GXH56B

SPW-KR164GXH56B

SPW-KR184GXH56B

SPW-KR254GXH56B

The slim line designed KR type wall mounted is small and light, making it ideal for commercial applications. It is also available in a wide variety of capacities.

• Smart colour and round-shape design with horizontal stripes

• Piping outlet in 3 directions

• Anti-mould filters are standard equipment

• Optional external electronic expansion valve kit

ATK-SURK160AGB prevents noise in quiet rooms and bedrooms

Washable front panel

The indoor unit’s front panel can be easily removed and washed for trouble-free cleaning.

Closed discharge port

When the unit is turned off, the flap closes completely to prevent entry of dust into the unit and to keep the equipment clean.

Quiet operation

These units are among the quietest in the industry, making them ideal for hotels and hospitals.

Piping outlet in three directions

Piping outlet is possible in the three directions of rear, right, and left, making the installation work easier.

Anti-mould filters are standard

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-SH1BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Fan motor

Cooling

Heating

Cooling

Heating

Type

A

Airflow rate (H/M/L) m³/min kW

BTU/h kW

BTU/h kW kW

A

Output

Power sound level (H/M/L)

Pressure sound level (H/M/L)

Height

Dimensions Width

Depth

Liquid

Pipe connetions

Gas

Drain piping

Net weight kW dB(A) dB(A) mm mm mm inches mm inches mm kg

SPW-KR74GXH56B SPW-KR94GXH56B SPW-KR124GXH56B SPW-KR164GXH56B SPW-KR184GXH56B SPW-KR254GXH56B

2,2

7500

2,5

8500

2,8

9600

3,2

11000

220/230/240V, 1 phase - 50, 60 Hz

3,6 4,5

12000

4,2

14000

15000

5,0

17000

0,031/0,033/0,035

0,031/0,033/0,035

0,15/0,15/0,15

0,15/0,15/0,15

Cross flow fan

5,6

19000

6,3

21000

7,3

25000

8,0

27000

0,049/0,052/0,055

0,049/0,052/0,055

0,23/0,23/0,24

0,23/0,23/0,24

10/8/6,0

0,011

47/43/39

36/32/28

285

995

203

1/4 (ø6.35)

1/2 (ø12.7)

12/10/8,0

0,015

16/14/10

0,023

53/49/46

42/35/38

330

1140

228

3/8 (ø9.52)

5/8 (ø15.88)

VP-13

14 21

Specifications subject to change without notice.

A21

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A22

FR type

floor standing

SPW-FR74GXH56B

SPW-FR94GXH56B

SPW-FR124GXH56B

SPW-FR164GXH56B

SPW-FR184GXH56B

SPW-FR254GXH56B

The compact floor standing FR units are the ideal solution for providing perimeter air conditioning.

The standard wired controller can be incorporated into the body of the unit.

• Pipes can be connected to either side of the unit from

the bottom or rear

• Easy to install

• Front panel opens fully for easy maintenance

• Removable air discharge grille gives flexible air flow

• Room for condensate pump

Effective perimeter handling

A standard wired remote control can be installed in the body.

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Cooling

Heating

Cooling

Heating

Type

Fan motor Airflow rate (H/M/L) m³/min

Output kW

Power sound level (H/M/L) dB(A)

Pressure sound level (H/M/L)

Dimensions

Pipe connections

Net weight

(HxWxD)

Liquid

Gas

Drain piping dB(A) mm inches mm inches mm kg kW

BTU/h kW

BTU/h kW kW

A

A

SPW-FR74GXH56B SPW-FR94GXH56B SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B SPW-FR254GXH56B

2,2

7500

2,5

8500

0,051/0,056/0,061

0,036/0,040/0,045

0,24/0,25/0,26

0,17/0,18/0,19

7/6/5

0,01

44/41/39

33/30/28

2,8

9800

3,2

11000

615x1065x230

220/230/240 1 phase - 50, 60 Hz

3,6 4,5

12000

4,2

15000

5,0

14000

0,079/0,085/0,091

0,064/0,070/0,076

17000

0,116/0,126/0,136

0,079/0,091/0,101

0,37/0,38/0,39

0,30/0,31/0,32

Sirocco fan

0,54/0,56/0,58

0,37/0,41/0,43

9/7/6

0,02

50/46/40

39/35/29

12/9/8

0,02

49/46/42

38/35/31

5,6

19000

6,3

21000

0,116/0,126/0,136

0,079/0,091/0,101

0,54/0,56/0,58

0,37/0,41/0,43

15/13/11

0,03

50/47/42

39/36/31

615x1380x230

7,1

24000

8,0

27000

0,150/0,160/0,170

0,110/0,120/0,130

0,70/0,72/0,73

0,52/0,54/0,56

17/14/12

0,06

52/49/46

41/38/35

1/4 (ø6.35)

1/2 (ø12.7)

3/8 (ø9.52)

5/8 (ø15.88)

VP-20

29 39

Specifications subject to change without notice.

A23

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A24

FMR type

concealed floor standing

SPW-FMR74GXH56B

SPW-FMR94GXH56B

SPW-FMR124GXH56B

SPW-FMR164GXH56B

SPW-FMR184GXH56B

SPW-FMR254GXH56B

At just 229mm deep, the FMR unit can be easily concealed in perimeter areas to provide powerful and effective air conditioning.

• Chassis unit for discrete installation

• Complete with removable filters

• Pipes can be connected to either side of the unit from the bottom or rear

• Easy to install

Perimeter air conditioning with high interior quality

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

Indoor unit specifications

Model Name

Power source

Cooling capacity

Heating capacity

Power input

Running amperes

Cooling

Heating

Cooling

Heating

Type

Fan motor Airflow rate (H/M/L) m³/min

Output kW

Power sound level (H/M/L) dB(A)

Pressure sound level (H/M/L)

Dimensions

Pipe connections

Net weight

(HxWxD)

Liquid

Gas

Drain piping dB(A) mm inches mm inches mm kg kW

BTU/h kW

BTU/h kW kW

A

A

SPW-FMR74GXH56B SPW-FMR94GXH56B SPW-FMR124GXH56B SPW-FMR164GXH56B SPW-FMR184GXH56B SPW-FMR254GXH56B

2,2

7500

2,5

8500

0,051/0,056/0,061

0,036/0,040/0,045

0,24/0,25/0,26

0,17/0,18/0,19

7/6/5

0,01

44/41/39

33/30/28

2,8

9800

3,2

11000

616x904x229

220/230/240 1 phase - 50, 60 Hz

3,6 4,5

12000

4,2

15000

5,0

14000

0,079/0,085/0,091

0,064/0,070/0,076

0,37/0,38/0,39

0,30/031/0,32

17000

0,116/0,126/0,136

0,079/0,091/0,101

Sirocco fan

0,54/0,56/0,58

0,37/0,41/0,43

9/7/6

0,02

50/46/40

39/35/29

12/9/8

0,02

49/46/42

38/35/31

5,6

19000

6,3

21000

0,116/0,126/0,136

0,079/0,091/0,101

0,54/0,56/0,58

0,37/0,41/0,43

15/13/11

0,03

49/46/42

39/36/31

616x1219x229

7,1

24000

8,0

27000

0,150/0,160/0,170

0,110/0,120/0,130

0,70/0,72/0,73

0,52/0,54/0,56

17/14/12

0,06

52/49/46

41/38/35

1/4 (ø6.35)

1/2 (ø12.7)

3/8 (ø9.52)

5/8 (ø15.88)

VP-20

21 28

Specifications subject to change without notice.

A25

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

R410A

A26

GU type

Total Heat Exchanger

SPW-GU055XH

SPW-GU075XH

SPW-GU105XH

SANYO’s heat recovery ventilation system allows total control via a system network whilst modulating the temperature and humidity of the incoming air supply.

Electric VRF, ECOi

Controller Options

Timer remote controller Wireless remote controller Simplified remote controller

RCS-TM80BG RCS-BH80BG.WL

RCS-KR1EG

• Integration of heat recovery ventilation and DX coil technology for optimum air temperature control

• The DX coil can be connected to all GHP outdoor units

• Humidifying function available as an option

• Easy to clean filter

• Compact design

• Humidifier and filter option

• Heat recovery: Solenoid valve kit is required for each unit

• Heat pump: RAP kit is required for each unit

Rap valve kit

ATK-RX160AGB

A27

Rap valve kit

EA

OA

R

Intake grille

RA

OA

EA

R

*Reduce pressure valve

*Stop valve for water supply

SA

SA

Distribution chamber

Inlet

RA

Outlet

B

*Water supply line

B

Using duct unit for supply and circulation air

A

A

Using duct unit for supply air

Using back of ceiling for circulation air

*These valves and line is necessary only when humidification is used.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Indoor unit specifications

Model Name

Air circulation (H) m³/h

Power source

Fresh air load treatment capacity

Cooling

Heating

Enthalpy Exchange

Efficiency

Temp exchange efficiency

Cooling

Heating kW kW

%

%

SPW-GU055XH

500

5,3 (1,7)*¹

6,5 (2,3)*¹

Equivalent cooling capacity

Power input

Running amperes

Cooling

Heating

Cooling

Heating

Fan motor

Type

External static pressure-return air

External static pressure-supply air

Output

Power sound level (C/H)

Pressure sound level (C/H)

Height mm kW

BTU/h kW kW

A

A

Pa

Pa kW dB(A) dB(A)

3,6

12000

0,532/0,532/0,532

0,532/0,532/0,532

2,5/2,4/2,3

2,5/2,4/2,3

183 (170)

205 (182)

0,28 (4P)x2

57 (Cooling), 58 (Heating)

46 (Cooling), 47 (Heating)

425

Dimensions

Pipe connections

Width mm

Depth mm

Liquid

Gas

Drain piping

Connection duct diameter inches mm inches mm mm

1785

1000

Net weight kg 134

The values in ( ) for the external static pressure and operating sound are for use of booster cable.

*1: Heat recovery capacity by heat exchanger.

250

SPW-GU075XH

750

220/230/240V, 1 phase - 50 Hz

8,2 (2,6)*¹

9,8 (3,5)*¹

59

67

75

5,6

19000

0,737/0,737/0,737

0,737/0,737/0,737

3,4/3,2/3,1

3,4/3,2/3,1

Sirocco fan

221 (188)

264 (218)

0,35 (4P)x2

58 (Cooling), 59 (Heating)

47 (Cooling), 48 (Heating)

450

1903

1120

1/4 (ø6.35)

1/2 (ø12.7)

VP-25

153

SPW-GU105XH

1000

10,7 (3,4)*¹

12,6 (4,6)*¹

7,3

25000

0,798/0,798/0,798

0,798/0,798/0,798

3,7/3,5/3,4

3,7/3,5/3,4

135 (88)

176 (137)

59 (Cooling), 60 (Heating)

48 (Cooling), 49 (Heating)

1220

300

168

Specifications subject to change without notice.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

A28

CFR type

Air Handling Unit

CFR/CFR-PHE

The CFR-PHE uses a unique purifying Bioxigen system to produce negative ions; this can reduce pollutants by up to 85% whilst significantly improving air quality within most environments.

CFR type

Air Handling Units with Heat Recovery

CFRS-AHU

CFRR-AHU

SANYO’s high quality engineering and components have allowed the development of highly energy efficient air handling systems.

Electric VRF, ECOi

CFR/ CFR-PHE

High efficiency heat exchanger and easy to clean filters

The CFR-PHE unit structure is constructed from

Aluzink frame work and galvanised steel with 20mm thick fire resistant acoustic insulation, reducing both weight and sound levels to a minimum.

The system is supplied with ducted spigots which can be positioned either at the front or side of the unit to ease installation.

The high efficiency low pressure loss total heat exchanger is made from specially treated paper to enable the unit to be as efficient as 76% during normal operation. This allows system to recover both latent and sensible heat.

Indoor unit specifications

Model CFR/ CFR-PHE

Nominal air flow *

External static pressure

Sound pressure **

Fans

Power input

Absorbed power

Fan speeds

Insulation class

Electrical supply

Bioxigen Elements (PHE only)

Number of elements

Electrical supply

Power in

Filter

Paper Heat Exchanger

Temperature Efficiency heating ***

Enthalpy Efficiency heating ***

Temperature Efficiency cooling ****

Enthalpy Efficiency cooling **** m³/hr pa dB(A)

W

A no

V/ph/Hz

V/ph/Hz

W

CFR-PHE

Temp.

Entha.

Temp.

Entha.

33

300

45

43

184

0,75

76%

62%

62%

60%

1

1 x C

4,5

* Nominal air flow

** Sound pressure 1,5m from the unit in free field

*** Data referred to Outdoor Temp. -5°C - 80% RH room condition 20°C - 50% RH

**** Data referred to Outdoor Temp. 32°C - 50% RH room condition 26°C - 50% RH

Specifications subject to change without notice.

180

1,8

74%

60%

60%

58%

55

620

55

51

A29

110

920

65

50

294

2,2

72%

56%

58%

55%

175

1580

70

53

700

4,4

230/1/50

F

2 x C

230/1/50

9

68%

55%

54%

53%

3EU

220

1850

77

52

700

4,8

3

73%

65%

59%

59%

255

2250

80

51

700

5,2

75%

67%

62%

62%

320

2950

100

54

1100

8,3

2 x F

12

70%

62%

56%

55%

410

3920

100

56

1500

5

2

400/3/50

66%

56%

52%

51%

ISO 14001:2001 does not apply

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

The CFRS-AHU series feature a cross-flow aluminium plate exchanger (medium efficiency of 55%). The CFRR-AHU series is equipped with absorption or rotary exchanger which allows the recovery of both sensible and latent heat, providing maximum efficiencies of 70%.

The cooling or heating is managed by a direct expansion coil using R410A refrigerant which enables higher efficiencies to be reached.

Model

Nominal air flow

Air flow range

External static pressure

Electrical supply

Total max absorbed current

Filters

Pleated filters efficiency (supply air and exhaust air)

Bag filters efficiency (supply air) m³/h m³/h

Pa

V, ph, Hz

A

500

5000

3500 + 5000

250

11

G4

F7

1000

10000

7000 + 10000

250

18,5

G4

F7

400, 3, 50

1500

15000

11000 + 15000

250

25,7

2000

20000

16000 + 20000

250

39

G4

F7

G4

F7

Specifications subject to change without notice.

ISO 14001:2001 does not apply

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

A30

VRF

Indoor Unit Dimensions

X Type

XM Type

LDR Type

Electric VRF, ECOi

DR Type

A31

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

A32

VRF

Indoor Unit Dimensions

US Type

Electric VRF, ECOi

FTR Type

U Type

T Type

A33

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

A34

VRF

Indoor Unit Dimensions

K Type

5 815

825

5

FILTER SIZE

(316 x 311 x 2) x 2pcs.

Dimensions: mm

Refrigerant tubing (liquid tube)

Ø

6.35 (flared)

Refrigerant tubing (gas tube)

Ø

12.7 (flared)

Drain hose VP13 (outer dia.

Ø

18)

Rear panel (PL BACK)

Rear panel fixing holes (

Ø

5 holes or 5 x 13 oval holes)

Piping & coiling holes (

Ø

65)

187 450 187

5cm

815

15cm

Front view

5cm

217

47

(1)

179

187.5

65

122.5

70

Gas tube

Liquid tube

825

450

360 308

179

Drain hose Ø18

187.5

92.5

65

KR Type

FR Type

FMR Type

Electric VRF, ECOi

A35

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

A36

VRF

Indoor Unit Dimensions

GU Type

Electric VRF, ECOi

CFR Type

G

A37

Model A B C D D1 D2

CFR 33

CFR-PHE 33

CFR 55

CFR-PHE 55

CFR 110

CFR-PHE 110

CFR 175

CFR-PHE 175

CFR 220

CFR-PHE 220

CFR 255

CFR-PHE 255

CFR 320

CFR-PHE 320

CFR 410

CFR-PHE 410

990

990

1140

1300

1380

1650

1650

1750

290

290

410

500

500

600

600

600

750

750

860

860

960

1230

1230

1330

/

/

260

290

310

410

410

410

/

/

95

77

87

91

91

116

115

77

87

91

91

116

(1) Only for “W” version

(2) Only for “CFR-PHE-E” models (with electric heater in external section)

/

/

E

410

410

410

210

310

/

/

330

F1

152

135

160

115

109

/

/

129

F

288

321

321

220

225

/

/

225

G

255

280

280

200

255

/

/

255

G1(1)

3/4

3/4

3/4

3/4

3/4

/

/

3/4

M(2)

250

/

250

/

250

/

250

/

250

/

250

/

/

250

/

250

Y

162

125

125

50

75

/

/

75

N(2)

450

/

430

/

480

/

570

/

380

/

380

/

/

570

/

570

Øi

/

/

/

/

/

460

355

/

Ø

/

/

/

/

/

160

200

/

80

125

138

160

174

190

Base

41

45

Version

“E”

179

187

195

203

88

127,5

133

140,5

146

165

173

42,5

46

46,5

50

82,5

82,5

127,5

140,5

165

179

196,5

“W”

/

/

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

A38

System Controls for VRF

A wide variety of control options to meet the requirements of different applications.

Electric VRF, ECOi

Operation system

Requirements

Normal operation

Individual control systems

Operation from each seat

Simple operation

Timer operation

Daily and weekly program

External appearance

Type, model name

Timer wired remote controller

RCS-TM80BG

Wireless remote controller

RCS-SH80BG.WL

RCS-SS80BG.WL

RCS-BH80BG.WL

RCS-TRP80BG.WL

RCS-SH1BG

RCS-XM18BG.WL

1 group, 8 units

Number of indoor units which can be controlled

1 group, 8 units

Use limitations

Up to 2 units can be connected per group.

Up to 2 units can be connected per group.

Connectable indoor unit

Function

ON/OFF

Mode setting

Fan speed setting

Temperature setting

Air flow direction

4/5 series indoor unit

*1

4/5 series indoor unit

Permit/Prohibit switching — —

Weekly program

*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)

*1

1 group, 8 units

Up to 2 units can be connected per group.

4/5 series indoor unit

*1

Simplified remote controller

RCS-KR1EG

Schedule timer

SHA-TM64AGB

64 groups, max. 64 units

Power supply from the system controller.

When there is no system controller, connection is possible to the T10 terminal of an indoor unit.

4/5 series indoor unit

C1

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Operation system Centralised control systems

Requirements

Operation with various function from central station

Only ON/OFF operation from central station

Simplified charge ratio for each tenant

Touch screen panel Personal computer (field supply)

External appearance

Web application

Type, model name

System controller

SHA-KC64AGB

ON/OFF controller

SHA-KC16KAGB

Intelligent controller

SHA-KT256EG

Communication adaptor

SHA-KA128AGB

Number of indoor units which can be controlled

Use limitations

Connectable indoor unit

Function

ON/OFF

Mode setting

Fan speed setting

Temperature setting

Air flow direction

Permit/Prohibit switching

Weekly program

64 groups, max. 64 units

Up to 10 units can be connected to one system.

Main unit/sub unit (1 main unit +

1 sub unit) connection is possible.

Use without remote controller is possible.

4/5 series indoor unit

*1

16 groups, max. 64 units

64 units x 4 networks, max. 256 units

Up to 8 units (4 main units + 4 sub units) can be connected to one system.

Use without remote controller is impossible.

A communication adaptor

(SHA-KA128AGB) must be installed for three or more networks.

4/5 series indoor unit

4/5 series indoor unit

*1

2 systems, max. 128 units

4/5 series indoor unit

*1

All specifications subject to change without notice.

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C2

Individual Control Systems

Electric VRF, ECOi

Control contents

Standard Control

• Control of the various operations of the indoor unit by wired or wireless remote controller.

• Cooling or heating mode of the outdoor unit is decided by the first priority of the remote controller.

• Switching between remote controller sensor and body sensor is possible.

Part name, model No. Quantity

Timer remote controller

RCS-TM80BG

Wireless remote controller

RCS-XM18BG.WL

RCS-SH80BG.WL

RCS-SS80BG.WL

RCS-BH80BG.WL

RCS-TRP80BG.WL

RCS-SH1BG

RCS-KR1EG

1 unit each

Timer remote controller

RCS-TM80BG

RCS-KR1EG

1 unit

(1) Group control

• Batch remote control on all indoor units.

• Operation of all indoor cells in the same mode.

• Up to 8 units can be connected.

• The sensor is the body sensor, and thermostat

ON/OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit.

(2) Main/sub remote control

• Max 2 remote controllers per indoor unit.

(Main remote controller can be connected)

• The button pressed last has priority.

• Timer setting is possible even with the sub remote controller.

Main or sub

Timer remote controller

RCS-TM80BG

Wireless remote controller

RCS-XM18BG.WL

RCS-SH80BG.WL

RCS-SS80BG.WL

RCS-BH80BG.WL

RCS-TRP80BG.WL

RCS-SH1BG

RCS-KR1EG

As required

System example ECOi/GHP

Remote controller

Standard control

Main Sub Main Sub

(2) Main/sub remote control

(1) Group control

System example PACi

Timer remote controller (RCS-TM80BG)

Dimensions

H 120 x W 120 x D 16 mm

Basic remote controller ON/OFF

• Operation mode changeover (Cooling, Heating, Dry,

Auto, Fan)

• Temperature setting (Cooling/Dry: 18-30 deg Heating:

16-30 deg)

• Fan speed setting H/ M/ L and Auto.

• Air flow direction adjustment

Time Function 24 hours real time clock

• Day of the week indicator

Weekly Programme Function

• A maximum of 6 actions can be programmed for each day

Outing Function

• This function can prevent the room temperature from dropping or rising when the occupants are out for a long time

Sleeping Function

• This function controls the room temperature for comfortable sleeping.

Max. 8 indoor units can be controlled from one remote controller.

Remote control by main remote controller and sub controller is possible

Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit

C3

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Wireless remote controller

RCS-BH80BG.WL

XM type

RCS-XM18BG.WL

RCS-BH80BG.WL

X type

RCS-SH80BG.WL

RCS-BH80BG.WL

XMR, SR, FTR types

RCS-SS80BG.WL

RCS-BH80BG.WL

ADR, T, LDR types

RCS-TRP90BG.WL

K type

RCS-SH1BG

RCS-BH80BG.WL

For all indoor units

RCS-BH80BG.WL

Ventilation independent operation is possible

When commercial ventilation fans or heat-exchange ventilation fans have been installed, they can be operated with this remote control (interlocked operation with the indoor unit or independent ventilation ON/OFF)

Easy installation for the 4-way cassette type simply by replacing the corner part

24 hour timer function

Remote control by main remote controller and sub controller is possible

• Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit

When RCS-BH80BG.WL is used, wireless control becomes possible for all indoor units

• When a separate receiver is set up in a different room, control from that room also becomes possible

• Automatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted

In addition, there are other functions such as temperature setting, operation switching, wind direction/fan speed setting, etc.

Simplified remote controller (RCS-KR1EG)

Dimensions H 120 x W 70 x D 16 mm

Remote sensor (ART-K45AGB)

A remote controller with simple functions and basic operation.

• Suitable for open rooms or hotels where detailed functions are not required.

• ON/OFF, operation mode switching, temperature setting, wind velocity switching, wind direction setting, alarm display, and remote controller self-diagnosis can be performed.

• Batch group control for up to 8 indoor units.

• Remote control by main remote controller and sub controller is possible with a simplified remote controller or a wired remote controller (up to two units).

• This is a remote sensor which can be used with 4 series indoor units. Please use it to detect the room temperature when no remote controller sensor or body sensor is used.

(connection to a system without a remote controller is possible).

• For joint use with a remote control switch, use the remote control switch as main remote controller

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C4

Centralised Control Systems

Electric VRF, ECOi

Schedule timer (RCS-TM64AGB)

Dimensions

H 120 x W 120 x D 16 mm

The power supply for the schedule timer is taken from one of the following

1. Control circuit board (T10) of a nearby indoor unit (power supply wiring length: within 200m from the indoor unit)

2. System controller (power supply wiring length: within 100m from the indoor unit)

When the power supply for the schedule timer is taken from the control circuit board of the indoor unit, that indoor unit cannot be used with other control devices using the T10 terminal.

As operation mode and temperature settings are not possible with the schedule timer, it must be used together with a remote controller, a system controller, an intelligent controller, etc. Also, as it does not have an address setting function, the control function of a system controller etc. must be used for address setting

Up to 64 groups (max. 64 indoor units) can be controlled divided into 8 timer groups

Six program operations (Operation/Stop/Local permission/

Local prohibition) per day can be set in a program for one week

• Only operation or stop, remote controller local permission or remote controller local prohibition, and their respective combinations are possible. (Operation + local permission, stop + local prohibition, only local permission, etc.)

• Local prohibition and the combination of the three items of temperature setting, mode change, and operation/stop can

be set at the time of installation

A function for pausing the timer in case of national holidays has been added, and timer operation also can be stopped for a long time

• By setting holidays or operation stop within one week, the timer can be paused just for that week.

• All timer settings can be stopped with the timer “ON/OFF effective” button. (Return to timer operation is made by pressing the button again.)

Connection example 1

(power supply from the indoor unit)

Connection example 2

(power supply from the central controller)

C5

Remote controller Schedule timer

Indoor/outdoor operation wire

System controller Schedule timer

Zone 1

Centralised addresses

1 to 16

1 2 8 9 10 16

Timer group 1: Centralised addresses 1 to 8

Timer group 2: Centralised addresses 9 to 16

Zone 2

Centralised addresses

17 to 32

17 18 24 25 26 32

Timer group 3: Centralised addresses 17 to 24 Timer group 4: Centralised addresses 25 to 32

Zone 3

Centralised addresses

33 to 48

33 34 40 41 42 48

Timer group 5: Centralised addresses 33 to 40 Timer group 6: Centralised addresses 41 to 48

Zone 4

Centralised addresses

49 to 64

49 50 56 57 58 64

Timer group 7: Centralised addresses 49 to 56 Timer group 8: Centralised addresses 57 to 64

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

ON/OFF controller (SHA-KC16KAGB)

Dimensions H 121 x W 122 x D 14 + 52

(embedding dimension mm)

Power supply AC 220 to 240 V

I/O part Remote input (effective voltage: within DC 240V): All ON/OFF

Remote output (allowable voltage: within DC 30V): All ON, All alarm

• 16 groups of indoor units can be controlled

• Collective control and individual group (unit) control can also be performed

• Up to 8 ON/OFF controller (4 main, 4 sub) can be installed in one link system

• The operation status can be determined immediately

Note: As operation mode and temperature settings are not possible with the ON/OFF controller, it must be used together with a remote controller, a system controller etc

Web Interface Device (SHA-KW64EG)

E mail Send

(alarm data)

Web

Interface

Device

1 Link System

LAN

・max. 64 indoor units.

Functions

• Access and operation by Web browser

• Icon display

• Individual control possible (max. 64 indoor units)

ON/OFF operation mode, set temperature,

Indoor/outdoor operation wire fan speed, Flap set, timer on/off alarm code monitoring, prohibit Remote Control

System controller

• Language codes available in English, French, German, Italian,

Portuguese, Spanish

Zone 1

Centralised addresses

1 to 16

1 2

• All Units control

8

• Alarm Log

9 10

• Mail Sent Log

16

• Program Timer set

50 daily timers with 50 actions each day, 50 weekly timers 50 weekly timers, 1 holiday timer, 5 special day timers, for each

Zone 2

Centralised addresses

17 to 32

Zone 3

Centralised addresses

33 to 48

17

33

18

34

24 26 32

• Prohibit Remote Control set

Timer group 3: Centralized addresses 17 to 24

Timer group 4: Centralized addresses 25 to 32

• IP ADDRESS could be changed via Internet

Note: it is recommended to install a remote controller or a system controller on site to enable local control if IT network experiance a problem.

40 41 42 48

Timer group 5: Centralized addresses 33 to 40 Timer group 6: Centralized addresses 41 to 48

Zone 1

Centralised addresses

49 to 64

49 50 56 57 58 64

Timer group 7: Centralized addresses 49 to 56 Timer group 8: Centralized addresses 57 to 64

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C6

Centralised Control Systems

Electric VRF, ECOi

System controller (SHA-KC64AGB)

Dimensions

Power supply

I/O part

160 x W 160 x D 21 + 69 (embedding dimension) mm

AC 220 to 240 V

Remote input (effective voltage: DC 24 V): All ON/All OFF

Remote output (voltage-free contact): All ON/All OFF

(external Power supply within DC 30 V, max 1A)

Total wiring length 1km

A control mode corresponding to the use condition can be selected from 10 patterns

A Operation mode: Central control mode or remote control mode can be selected

Central control mode: The system controller is used as centralised control device. (Setting from a remote controller can be prohibited by prohibiting local operation from the system controller.)

Remote control mode: The system controller is used as a remote controller. (Setting from the system controller can be prohibited by prohibiting local operation from another central control unit.)

B Controlled unit number mode: All mode or zone 1, 2, 3, 4 mode can be selected

All mode: All, zone, or group unit can be selected.

Zone 1, 2, 3, 4 mode: Setting is possible only for the indoor units of zone 1, 2, 3, or 4.

Connection example

B

Controlled unit number mode

All mode

Zone 1 mode

Zone 2 mode

Zone 3 mode

Zone 4 mode

A

Operation mode

Central control mode Remote control mode

All central control

Example 1

All remote control

Zone 1 central control

Example 2

Zone 1 remote control

Zone 2 central control

Zone 2 remote control

Example 3

Zone 3 central control

Example 4

Zone 3 remote control

Zone 4 central control

Zone 4 remote control

Example 5

Individual control is possible for max. 64 groups, 64 indoor units.

Control of 64 indoor units divided into 4 zones. (One zone can have up to 16 groups, and one group can have up to 8 units.)

Control is possible for ON/OFF, operation mode, fan speed, air flow direction (only when used without a remote controller), operation monitoring, alarm monitoring, ventilation, remote controller local operation prohibition, etc

Individual All operations are possible also from the remote controller. However, the contents will be changed to the contents of the controller operated last

Central 1 The remote controller cannot be used for ON/OFF.

(All other operations are possible from the remote controller.)

Central 3 The remote controller cannot be used for mode change or temperature setting change. (All other operations are possible from the remote controller.)

Central 4 The remote controller cannot be used for operation mode change. (All other operations are possible from the remote controller.)

Joint use with a remote controller, an intelligent controller, a schedule timer, etc. is possible

(The maximum number of connectable system controllers is

10, including other central controllers on the same circuit.)

(In case of joint use with a wireless remote controller, there are limitations for the control mode. Please use only with

“Individual” and “Central 1”.)

Control of systems without a remote controller and of main/sub systems (a total of up to 2 units) is possible

System controller

(Control mode example 2: Central control for zone 1)

Individual remote controller

System controller

Group control

(Control mode example 3: Remote control for zone 2)

System controller

(Control mode example 4: Central control for zone 3)

System controller

System without a remote controller

(Control mode example 5: Remote control for zone 4)

Individual remote controller

Control of a group without remote controller

System controller

(Control mode example 1:

All central control)

C7

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Intelligent controller (SHA-KT256EG)

Touch panel

Dimensions

Power supply

I/O part

H 240 x W 280 x D 138 mm

AC 100 to 240 V (50 Hz), 20 W (separate power supply)

Remote in put (voltage-free contact): All ON/OFF

Remote output (voltage-free contact): All ON, All alarm

(external power supply within DC 30V, 0.5A)

Total wiring length 1 km for each system

Only for embedding in the panel

ON/OFF, operation mode setting, temperature setting, for fan speed setting, air flow direction setting (when used without a remote controller), and remote controller local operation prohibition (prohibition 1, 2, 3, 4) can be done

A system without a remote controller is possible. Joint use with a remote controller or a system controller is also possible

Use of a schedule timer and holiday setting also can be done

Proportional distribution of the air conditioning energy is possible. Including csv-file export via CF-card

(supplementary accessory).

NEW function: Pulse signal input from electric/gas consumption meter

In case of joint use with a wireless remote control system, there are limitations for the control mode. Please use only with “Permission” and “Prohibition 1”

Limitation contents for prohibited operation

Prohibition means limitation of the operation contents from the remote controller. It is also possible to change the prohibition items.

Web application

Limitation contents (Limitations can be user defined)

Individual There is no limitation for the operation of the remote controller. However, the contents will be changed to the contents of the controller operated last. (Last-pressed priority.)

Prohibition 1 The remote controller cannot be used for

ON/OFF. (All other operations are possible from the remote controller.)

Prohibition 2 The remote controller cannot be used for

ON/OFF, operation mode change and temperature setting. (All other operations are possible from the remote controller.)

Prohibition 3 The remote controller cannot be used for operation mode change and temperature setting. (All other operations are possible from the remote controller.)

Prohibition 4 The remote controller cannot be used for operation mode change. (All other operations are possible from the remote controller.)

Note: Avoid joint use of the AMY system and the intelligent controller on the same indoor/ outdoor operation line

Intelligent controller

SHA-KT256EG

System signal x 4

RS 485

(Polarity shield wire)

Communication adapter

SHA-KA128AGB

Max. 256 indoor units (4 systems x 64 units) can be controlled. In case of three or more systems, a communication adapter SHA-KA128AG must be installed on the outside

Operation is possible as batch, in zone units, in tenant units and in group units

Display sample

System signal x 4

Communication adaptor (SHA-KA128AGB)

For more information on how to connect please see installation manual.

Dimensions H 260 x W 200 x D 68 mm

Power supply AC 100 to 240 V (50 Hz),

3 W (separate power supply)

Linked system No. 1

Linked system No. 2

Linked system No. 3

Linked system No. 4

Max. 4 links can be connected for the indoor/outdoor operation line

= Max. 64 indoor units x 4 (256 units)

Max. 30 outdoor units x 4 (120 units)

Required to connect three or more linked wiring systems

(indoor/outdoor operation lines) to the intelligent controller

Also required for connection of the AMY software and

STAIMS

Two linked wiring systems can be connected to one SHA-

KA128AG, but max. 4 systems can be connected for the entire intelligent controllers

* As this is not a splash-proof design, it must be installed indoors or in the control panel etc

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C8

Interfaces for External Control

Electric VRF, ECOi

Seri-Para I/O unit (ACC-SP16TAGB)

• This is the interface for connecting signals from the central control device with the SANYO air conditioner unit control network

• This unit can control and monitor the status up to 16 groups of indoor units (max 64 indoor units)

• Up to 4 seri-para units can be connected in one system

• From the central control device, it is possible to set the temperature and to monitor the room temperature or intake air temperature

System example

Seri-para I/O

Input ON/OFF (Pulse DC24V)

Local prohibit (Continuous DC24V)

Temp setting (Analog DC1~5V)

All ON/OFF (Pulse DC24V)

All local prohibit and emergency stop (Continuous DC24V)

Output On/Alarm/Answer back/Filter sign

Room temp (Analog DC4-20mA)

All ON/OFF

Seri-Para I /O unit for outdoor unit (ACC-XSP4U1GB)

Dimensions H 80 x W 290 x D 260 mm

Power supply Single phase 100/200V

(50/60 Hz), 18W

Input Batch operation/Batch stop

(non-voltage contact/DC

24V, pulse signal)

Cooling/Heating

(non-voltage contact/static signal)

Demand 1/2

(non-voltage contact/ static signal) (Local stop by switching)

Output Operation output

(non-voltage contact)

Alarm output

(non-voltage contact)

Wiring length Indoor/Outdoor operation lines: Total length 1km

Digital signal:

100m or shorter

• This unit can control up to 4 outdoor units.

• From the centre control device, mode changing and batch operation/batch stop are possible

• Required for demand control.

System example

Seri-para I/O

Local adaptor for ON/OFF control (SHA-KL4UGB)

• Control and status monitoring is possible for individual indoor unit (or any external electrical device up to 250V AC, 10A) by contact signal.

SHA-KL4UGB

System example

ON/OFF controller

For example: fan coil unit etc.

total heat exchanger unit.

C9

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

MINI Seri-Para I/O Unit (ACC-SP1AGB)

• Power is supplied from the T10 terminal of the indoor units

• Separate power supply also is possible (in case of suction temperature measuring)

System example

• Control and status monitoring is possible for individual indoor unit (1 group)

• In addition to operation and stop, there is a digital input function for air speed and operation mode

• Temperature setting and measuring of the indoor suction temperature can be performed from central monitoring

• The analog input for temperature setting is 0 to 10 V, or 0 to 140 Ohm

System example

Indoor/outdoor unit control line

LON

System Controller

LonWorks interface

LON

LonWorks communication line

Centre Control

Device

Remote station

ACC-SP1AGB

Central control panel

LonWorks interface (SHA-LN16UGB)

• This interface is a communications converter for connecting

LonWorks to the SANYO air conditioner unit (PAC, ECOi,

GHP) control network

• From the host connected to LonWorks, basic settings and status monitoring is possible for up to 16 groups of A/C units

Functions

A/C unit settings from the LonWorks communicator

Settings for each group of indoor units

Settings for all units

System example

Start/stop

Temp. setting

Operation mode

Option 1 settings*

Option 2 settings*

Emergency stop

Start/stop

Temp setting

Operation mode

Option 1 settings*

A/C unit status notifications made to the LonWorks communicator

Option 2 settings*

Alarm status

Indoor units with active alarms

Room temperature

A/C unit status

Configuration properties

Transmission intervals settings

Minimum time secured for transmission

* Select two of the following: remote controller prohibit, fan speed setting, air direction setting, filter sign reset.

Signal output board (ACC-SG-AGB)

• Defrost, heating, cooling and thermostat ON signal can be put out to the outside.

• Signal type (2 types): Voltage specification (max. 240V AC, 5A or 30V DC, 5A), non-voltage specification

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C10

BMS Software

Electric VRF, ECOi

AMY Software

An air conditioner central control system for buildings

AMY software is an air conditioner (A/C) central control system for buildings

Functions

A/C unit settings

A/C unit status

C11

RS485/RS232C

Adaptor

(Field supply)

Communication adaptor

(RS-232C) (RS-485)

Outdoor unit

Max. 16 system

Connectable I/D units: Max. 512

Unit ON/OFF

Mode-change

Room temperature setting

Fan speed setting

Flap setting

Central control setting

Filter-sign clear

Alarm reset

Unit ON/OFF status

Operation mode

Setting temperature

Fan speed status

Flap status

Central control setting

Filter-sign situation

Correct/incorrect status

Alarm code

Charge calculation rate

Outdoor unit

Outdoor unit

Remote controller

Outdoor unit

Remote controller

Group control

Remote controller

Group control

Max. 64 I/D

Remote controller

Group control

Max. 64 I/D

STAIMS Basic software TECS-5000KG

SANYO Total Air conditioning Intelligent Management System

Up to 1024 indoor units can be controlled by one PC

Functions for basic software

• Standard remote control for all indoor units.

• Many timer schedule programs can be set on the calendar.

• Detail information display for alarm happening.

• CSV file output with alarm history, operating status.

• Automatic data backup to HDD.

By using up to 4 optional software modules a more comfortable control is possible.

TECS-5000AG for Load distribution

Load distribution calculation for each tenant

• Air-con load distribution ratio is calculated for each unit

(tenant) with used energy consumption data (m3, kWh).

• Calculated data is stored with

CSV type file.

• Data of last 365 days will be stored.

TECS-5000BG for BACnet interface

Connectable to BMS system

• Communicate with other equipments by BACnet protocol.

• SANYO airconditioners system can be controled by both BMS and STAIMS.

• Up to 256 indoor units can be connected to one PC (that has

STAIMS basic and BACnet software).

TECS-5000GG for Object layout display

Whole system can be controlled visually

• Operating status monitor is available on the layout display.

• Object’s layout and indoor unit’s location can be checked at once.

• Each unit can be controled by virtual remote-controller on the display.

• Up to 4 layout screens are shown at once.

TECS-5000WG for

Web application

Web access and control from remote station

User PC

• Accessing STAIMS software from remote PC.

• You can monitor/operate SANYO system by using web browser

(Internet Explorer).

AIMS is suitable for large shopping centers and universities with many areas/ buildings. 1 "ST

STAIMS is suitable for large shopping centres or Universities that have large areas/many buildings.

User PC

1 STAIMS PC can have 4 independent systems at once. Each system can have up to 8 C/A units, and control up to 512 units.

In total, 1024 indoor units can be controlled by 1 STAIMS PC.

User PC

Communication

Adaptor

Communication

Adaptor

Communication

Adaptor

Communication

Adaptor

User PC

Software environment

OS Windows 2000,

Windows NT 4.0 Service

Pack 6 or above

Browser Internet Explorer 4.0 or above

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Communication

Adaptor

• Up to 8 C/A for 1 system

• Wiring length for each link from C/A up to 1 km

Communication

Building A

Communication

Adaptor

Communication

Adaptor

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB communication adapter

SHA-KA128AG

Communication

Adaptor

Building A

Building A

Building B

Building B

Building D

Building D

C12

Building D

Communication

Adaptor

Communication

Adaptor

Building D

Communication

Adaptor

Building A

Building B

Building D

PAC2 System Design Software

PAC2 System Design Software

System designing for VRF (ECOi and GHP) and PACi

Commercial Split Systems has never been easier

SANYO has identified the importance of ever-increasing demands for fast and accurate responses to customer requests in our industry. More and more emphasis is being placed upon energy-efficiency in our marketplace. The ability to calculate cooling/heating loads and produce information of actual design conditions is a major advantage to any architect, consultant, contractor or end user.

SANYO understands the ever-changing and demanding industry we are in and we are pleased to announce the launch of the next generation of our system design software program. The advanced PAC2 system design software has been customised to make any selection and design process as quick and easy as possible. The software features a version of AC Calc Lite

(produced by Click Software). This allows small building loadings to be accurately calculated and directly imported into the PAC2 software.

The design package utilises system wizards and import tools to enable both simple and complex systems to be created.

In addition, the system will allow outdoor and indoor units to be dragged and dropped on an interactive desktop. This allows users to create everything from realistic floor plans with detailed piping and wiring schematics to send out with quotations, through to installation guidance drawings.

The PAC2 system software can be used for all

SANYO ECOi, GHP and PACi systems.

Features include

• AC Calc Lite (included in the package)

• Easy to use system wizards

• Auto piping and wiring features

• Converted duties for conditions and pipework

• Auto CAD (DXF), Excel and PDF export

• Detailed wiring and pipework diagram

Electric VRF, ECOi

The PAC2 system software can be used for all SANYO ECOi, GHP and PACi systems.

C13

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C14

Control Equipment External Dimensions

Timer remote controller

(RCS-TM80BG)

4

Wireless remote controller

61 19.5

Separate receiver for wireless remote controller

4.4 x 9.4 slot

Simplified remote controller

(RCS-KR1AGB)

Remote sensor

(ART-K45AGB)

70

120

System controller

(SHA-KC64AGB)

116

47

160

21 69

4.4 x 5.4 slot

35

70

Intelligent controller

(SHA-KT256EG)

280

238

20 118

13

Communication adapter

(SHA-KA128AG(B))

200

C15

121

ON/OFF controller

(SHA-KC16KAGB)

116

47

Seri-Para I/O unit for 16 groups indoor unit

(ACC-SP16TAG)

4-ø0.5 hole

7.5

Seri-Para I/O unit for each indoor unit

(ACC-SP1AGB)

256

160

14 69

122

LonWorks interface

(SHA-LN16UGB)

10

500

460

360

6

4

Potbellied hole (4 locations)

50

15

420

520

50

7.5

18-ø31.0 hole, opposite side included

204.0

10

Seri-Para I /O unit for outdoor unit

(ACC-XSP4U1GB)

270

255

260

ø 5

ø10

180

3-

ø3

0 ho le

10

4-ø

5 h ole

R2.5

90 50

R5

Detail of the potbellied hole

80

290

ø 5

Magnified view

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

Timer remote controller

(RCS-TM80BG)

4

Wireless remote controller

61

19.5

Separate receiver for wireless remote controller

4.4 x 9.4 slot

Simplified remote controller

(RCS-KR1AGB)

Remote sensor

(ART-K45AGB)

70

120

System controller

(SHA-KC64AGB)

116

47

160

21 69

4.4 x 5.4 slot

35

70

Intelligent controller

(SHA-KT256EG)

280

238

20 118

13

Communication adapter

(SHA-KA128AG(B))

200

Electric VRF, ECOi

121

ON/OFF controller

(SHA-KC16KAGB)

116

47

Seri-Para I/O unit for 16 groups indoor unit

(ACC-SP16TAG)

4-ø0.5 hole

7.5

Seri-Para I/O unit for each indoor unit

(ACC-SP1AGB)

256

160

14 69

122

LonWorks interface

(SHA-LN16UGB)

10

500

460

360

6

4

Potbellied hole (4 locations)

50

15

420

520

50

7.5

18-ø31.0 hole, opposite side included

204.0

10

Seri-Para I /O unit for outdoor unit

(ACC-XSP4U1GB)

270

255

260

ø 5

ø10

180

3-

ø3

0 ho le

10

4-ø

5 h ole

R2.5

90 50

R5

Detail of the potbellied hole

80

290

ø 5

Magnified view

Rating Conditions: Cooling Indoor 27

°

C DB 19

°

C WB Outdoor 35

°

C DB 24

°

C WB Heating Indoor 20

°

C DB Outdoor 7

°

C DB 6

°

C WB

C16

Notes Notes

C17 C18

Indicates conformation with EC Directives

ISO 9001: 2001

Certificate Number: JQ116B

ISO 14001: 2001

Certificate Number: ECOOJ0303-33

SANYO reserves the right to make any variation in specification to the equipment described or to withdraw or replace products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication are given in good faith, but are intended to present only general particulars and shall not form any part of the contract. For full installation details, please contact your

SANYO distributor.

Rating Conditions

The cooling and heating capacities are based on the following conditions:

Cooling: Indoor temperature 27˚C DB / 19˚C WB, Outdoor temperature 35˚C DB / 24˚ C WB.

Heating: Indoor temperature 20˚C DB, Outdoor Temperature 7˚C DB.

www.sanyoaircon.com

© 2010.06 SANYO VRF-ENV1