MODEL QTXE110SFLT FAN / FLuORESCENT LIGHT / NIGHT LIGHT SPECIFICATION SHEET

MODEL QTXE110SFLT FAN / FLuORESCENT LIGHT / NIGHT LIGHT SPECIFICATION SHEET
SPECIFICATION SHEET
model QTXE110sflt
Fan / fluorescent LIGHT /
NIGHT LIGHT
AUTOMATIC CONTROL:
• Humidity control automatically turns fan ON when either of these
conditions is detected:
- a rapid to moderate (user adjustable) increase of humidity
- humidity above user-adjustable set-point (50%-100% RH)
• Two wire manual operation for odor control - Turns fan ON when power
line through wall switch is cycled ON, OFF and back ON
• Remains ON for a user-adjustable 5 to 60 minutes after humidity has
stabilized and is below set-point or after manually initiated through power
line cycling
• Saves energy because unit runs only for the time required. A unit
controlled with a wall timer may keep fan ON longer than required or turn
it OFF before room is sufficiently ventilated
A modern-styled, high performance fan/light with
sensing circuitry that “knows” when to ventilate
the room.
FEATURES
BLOWER:
• Plug-in, permanently lubricated motor - engineered for
continuous operation
• Dynamically balanced centrifugal blower wheel for quiet, efficient
performance
• Maintains a high percentage of rated CFM in less than ideal
installations
• Low RPM for quiet operation
ACCESSORY CONTROLS (Purchase separately):
Designed by Broan for use with this product (purchase separately)
• Model 77W, P77W, P77DW, 77DW (White Wall Plate)
• Model 66V, P66V (Ivory) / 66W, P66W (White) 3-Function Control
• Model 77V, 77DV (Ivory Wall Plate)
• Model 65V, P65V / 65W, P65W 3-Function Control (Polished Brass Wall
Plate)
• Model 67V, P67V / 67W, P67W 3-Function Control (Polished Chrome
Wall Plate)
• Model 68V, P68V (Ivory) / 68W (White) 2-Function Wall Control
HOUSING:
• Rugged, 26 gauge, galvanized steel construction
• 6” round ducting for superior performance
• Polymeric duct connector with tapered sleeve and no metallic
clatter
• 7-5/8” height allows for 2” x 8” (nominal) joist installations
• Sturdy, easy, four-point mounting directly to joist
• Includes unique spacer (patent pending) for mounting to
engineered “I” joists
• Includes hanger bars to position housing anywhere between 16”
to 24”-on-center joists
• Two sets of mounting holes for hanger bars allow flush
installation with bottom or top of drywall
GRILLE:
• Integrated humidity sensor
• Polymeric construction
• Innovative design - the result of extensive research with
designers and consumers
• 42W fluorescent lamp * (bulb included) and 4W night light
(bulb not included)
• Durable steel reflector with white enamel finish
U.L. Listed for use over bathtubs and showers when connected to a GFCI
protected branch circuit (ceiling mount only).
U.L. Listed for use in insulated ceilings (TYPE I.C.)
California Title 24 compliant.
3-Year Warranty
* Use only one of the following 42W fluorescent lamps:
G.E.
F42TBX/835/A/ECO or F42TBX/830/A/ECO or F42TBX/827/A/ECO
PHILIPS
PL-T 42W/35/4P/ALTO or PL-T 42W/30/4P/ALTO or PL-T 42W/27/4P/ALTO
SYLVANIA
CF42DT/E/IN/835 or CF42DT/E/IN/830 or CF42DT/E/IN/827
NEMA Type CFTR42W/GX24q/835 or CFTR42W/GX24q/830 or CFTR42W/GX24q/827
Broan
99271358
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
90D
99043593E
TYPICAL SPECIFICATION
Blower assembly shall be removable, have a centrifugal-type blower wheel and a
permanently lubricated motor designed for continuous operation.
Ceiling Ventilator shall be Broan Model QTXE110SFLT.
The unit will have a control that will automatically turn fan ON when humidity
increase is rapid to moderate (user adjustable), or when humidity is higher
than user-adjustable set-point (50%-100% Relative Humidity), or when supply
power is cycled from ON (for more than a second) to OFF (for less than a
second) and back ON. It shall be user-adjustable to turn OFF 5 to 60 minutes
after humidity has stabilized and is below user-adjustable set-point, or after
manually initiated by supply power cycling.
Non-metallic damper/duct connector shall be included.
Lamp shall be 42W fluorescent * with separate 4W night light.
Air delivery shall be no less than 110 CFM and sound level no greater than 0.7
Sones. All air and sound ratings shall be certified by HVI.
Ceiling ventilator shall be Energy Star® qualified and have an energy efficient
permanent split capacitor motor.
Ceiling Ventilator shall have corrosion resistant galvanized steel housing with
four-point mounting capability. It shall be ducted to a roof or wall cap using 6”
round ductwork.
Ceiling Ventilator shall be U.L. Listed for use in insulated ceilings (Type I.C.) and for use
over bathtubs and showers when connected to a GFCI protected branch circuit.
PERFORMANCE RATINGS
MODEL QTXE110SFLT
FAN / FLUORESCENT LIGHT / NIGHT LIGHT
HVI PERFORMANCE
Sones @0.1” Ps
0.7
CFM
@0.1” Ps
110
HVI-2100 certified ratings comply with
new testing technologies and procedures
prescribed by the Home Ventilating Institute, for
off-the-shelf products, as they are available to
consumers. Product performance is rated at 0.1
in. static pressure, based on tests conducted
in a state-of-the-art test laboratory. Sones are
a measure of humanly-perceived loudness,
based on laboratory measurements.
MODEL QTXE110SFLT
0.7
0.6
0.5
Ps (in. w .g.)
Model
QTXE110SFLT
AIR FLOW PERFORMANCE
0.4
0.3
0.2
0.1
AMPS
Model
QTXE110SFLT
WEIGHT
Amps*
1.0
* Total connected load
Model
Shipping
Weight
QTXE110SFLT 13.2 lbs.
0.0
0
10
20
30
40
50
60
70
80
90 100 110 120 130
Airflow (cfm )
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711