R. STAHL ET-xx7 ET-4x7 Panel PC, ET-xx7 ET-5x7, ET-6x7 Remote HMI Operating instructions
Below you will find brief information for ET-xx7 ET-4x7, ET-xx7 ET-5x7, ET-xx7 ET-6x7. These are explosion-protected equipment for installation in hazardous areas and can be operated in zones 1 and 21 with interfaces for zones 0/1/2 and 20/21/22. The devices are connected to a communication system via the serial interfaces (RS-232, Ethernet) located in their connection box at the rear. The connection box also contains the USB interfaces for the connection of various peripheral devices.
PDF
Download
Document
Advertisement
Advertisement
Operating instructions Series ET-xx7 Panel PC ET-4x7 Remote HMI Thin Client ET-5x7 Remote HMI KVM ET-6x7 R. STAHL HMI Systems GmbH Im Gewerbegebiet Pesch 14 D-50767 Köln HW-Rev. ET-xx7: Doc.No.: Operating Instructions Version: Issue date: 01.02.00 6000076 01.02.01 23.07.2013 Series ET-xx7 Publisher Publisher Publisher and copyright holder: R. STAHL HMI Systems GmbH Im Gewerbegebiet Pesch 14 D-50767 Köln Registered place of business: Court of registration: VAT number: Cologne District court Cologne, HRB 30512 DE 812 454 820 Telephone: (switchboard) (Hotline) Telefax: E-mail: (switchboard) (Hotline) +49/(0)221/ 5 98 08 - 200 - 59 - 260 [email protected] [email protected] • All rights reserved. • This document may not be reproduced in whole or in part except with the written consent of the publisher. • We reserve the right to make technical changes without notice. This documentation has been produced and checked with due care. STAHL HMI Systems GmbH shall, however, not accept liability for any mistakes in this and all other documents. Any warranty claims are limited to the right to demand amendments. Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation. We reserve the right to change our products and their specifications at any time, provided it is in the interest of technical progress. The information in the current manual (online or on CD/DVD) or in the operating instructions included with the HMIs applies. Trademarks The terms and names used in this document are registered trademarks and/or products of the companies in question. WINDOWS ® 95/98/2000/NT/ME/XP/Vista/7/Server are registered trademarks of MICROSOFT Corporation, USA. Copyright © 2013 by R.STAHL HMI Systems GmbH. Subject to alterations. Page 2 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Table of contents Table of contents 1 2 2.1 2.2 2.3 3 3.1 4 4.1 5 6 6.1 6.2 6.3 6.3.1 6.4 7 8 8.1 9 9.1 9.2 9.3 10 10.1 10.2 10.3 11 11.1 11.2 11.3 11.3.1 11.4 11.5 12 12.1 12.2 13 13.1 13.2 14 Description Publisher Table of contents Preface Device function Panel PC ET-4x7 Remote HMI Thin Client ET-5x7 Remote HMI KVM ET-6x7 Type allocation Type marking Technical Data In addtion to ET-4x7 (Panel PC) Conformity to standards Certificates ATEX IECEx GOST-R Operating licence KGS Marking Power supply HMIs Permitted maximum values External, non-intrinsically safe circuits External inherently safe optical interface External intrinsically safe circuits Type code Panel PC ET-4x7 Remote HMI Thin Client ET-5x7 Remote HMI KVM ET-6x7 Safety information General Safety Information Warning Safety information for installation HMI device installation in housings type of protection "e" or "t" Safety information for operation Special conditions Assembly and disassembly General information Cut-out ET-xx7 Operation General information Connections Maintenance R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 2 3 5 5 5 5 5 6 6 6 8 8 9 9 9 9 9 9 10 11 11 11 11 12 12 13 13 14 15 16 16 16 16 18 18 18 19 19 19 19 19 20 22 Page 3 of 32 Series ET-xx7 15 15.1 16 16.1.1 17 17.1 17.1.1 17.1.2 18 19 Page 4 of 32 Table of contents Troubleshooting Repairs / hazardous substances Disposal ROHS directive 2002/95/EC Front panel resistance Materials Material properties Touch membrane (polyester) Declaration of EC conformity Release notes 22 22 22 22 23 23 23 23 26 28 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 1 Preface Preface These operating Instructions contain all aspects relevant to explosion protection for the ET-xx7 HMIs (Panel PC and Remote HMI series). They also contain information on the connection and installation of these devices. All data relevant to explosion protection from the EC-type examination certificate were copied into these operating instructions. In the case of any discrepancies the original ECtype examination certificate applies. For the correct operation of all associated components please note, in addition to these operating instructions, all other operating instructions enclosed in this delivery as well as the operating instructions of the additional equipment to be connected. All certificates pertaining to the HMIs have been collected in the CE_ET-xx7 document, which is not part of the delivery. You can find this document on our website (www.stahl-hmi) or request it from STAHL HMI Systems GmbH. For more information on the HMIs please also refer to the Manual (available as online manual on www.stahl-hmi). 2 Device function The ET-xx7 HMIs are explosion-protected equipment for installation in hazardous areas and can be operated in zones 1 and 21 with interfaces for zones 0/1/2 and 20/21/22. The devices are connected to a communication system via the serial interfaces (RS-232, Ethernet) located in their connection box at the rear. The connection box also contains the USB interfaces for the connection of various peripheral devices. Furthermore, the interfaces for keyboard, mouse, video and audio signals are also located here. 2.1 Panel PC ET-4x7 The ET-4x7 HMI Panel PCs are intelligent display and operating devices which can run any software and are thus easy to operate. The devices are fitted with powerful processors and are thus able to process even large applications on-site. The devices have a back-up and recovery system which can be used to save complete images and load them onto new Panel PCs without requiring specific IT skills. The X13 interface is provided for this purpose. 2.2 Remote HMI Thin Client ET-5x7 The Remote HMIs of the ET-5x7 series can be integrated into modern networks as Thin Clients or with a KVM box via KVM-over-IP. Digital Ethernet technology is used for the data transfer between KVM box and Remote system. Up to four Remote HMIs can access one KVM box with one software license, thus costeffectively communicating with several PCs - for example, when monitoring the production process and simultaneously applying Condition Monitoring. Multi-monitoring with several on-site terminals can as easily be implemented as the application as Thin Client in a server environment with virtual work stations. 2.3 Remote HMI KVM ET-6x7 The KVM Classic transfer technology is used for the point-to-point connection between a PC and an ET-6x7 Remote HMI device. There are three versions (DVI1, DVI2 and DVI3) of this transfer technology that have slightly different functionality. R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 5 of 32 Series ET-xx7 3 Type allocation Type allocation Since the beginning of 2013, the T-series devices have been allocated new type names according to the following pattern: To avoid the bother of having to re-write certifications, the names in the certificates remain the same, but the devices receive new names. In the interest of a clear link between device type and certificate, both device names are listed on the type plate from 01.04.2013 onwards. 3.1 Type marking Old (certificate) New T-Ex-##*-CAT7*-R2 T-Ex-##*-CAT7*-R2 T-Ex-##*-MM*-R2 T-Ex-##*-SM*-R2 ET-##7*-TX* ET-##7*-CAT* ET-##7*-MM* ET-##7*-SM* * = random alphanumeric or symbolic characters without relevance to explosion protection # = random numeric character without relevance to explosion protection For the exact new device name and model please refer to the type code. 4 Technical Data Function / Equipment ET-467 ET-567 ET-667 Display type Display size Resolution in pixels Format Display Touch Screen (optional) Backlight Service life (MTBF) of backlight at 20°C Brightness Contrast Additional keyboard (optional) Power supply Connections Voltage supply Power consumption [A] Power Recommended fuses Max. operating voltage Um only for ET-4x7 and ET-5x7 Real-time clock Data buffer Battery Capacitor Page 6 of 32 56 cm (22") WSXGA+ 1680 x 1050 16:10 ET-477 ET-577 ET-677 TFT Color display 16.7 million colours 61 cm (24") Full HD 1920 x 1080 16:9 Glass Membrane or glass surface 5-wire analogue resistive LED background lighting ET-487 ET-587 ET-687 61 cm (24"WU) WUXGA 1920 x 1200 16:10 typically 50,000 h 250 cd/m² 300 cd/m² 1000 : 1 107 keys with integrated trackball / joystick / mouse pad or touch pad Directly in the integrated Ex-e connection box via screw terminals, green flexible cable up to 2.5 mm² (AWG 16) fixed cable up to 4 mm² (AWG 14) 24 VDC (20 - 30 V) or 100 - 240 VAC, 50 - 60 Hz at 24 VDC = max. 3 A at 100 - 240 VAC = max. 1 A typically 35 W / max. 150 W (typically 119 BTU / max. 510 BTU) 4 AT 250 VAC Yes Lithium battery and capacitor buffered, maintenance-free > 5 years at least 4 days R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Technical Data Interfaces Ethernet Copper (TX) Either copper or optical fibre 10/100BaseTx, 10/100 Mbit, (Ex-e) only for ET-6x7 direct connection Gigabit 100BaseFx, 100 Mbit, intrinsically safe (Ex op is) Optical fibre (MM/SM) (SX) Cable type Optical fibre MM Optical fibre SM USB USB Serial Video In (optional) Audio Data cable lengths Optical fibre MM only for ET-6x7 direct connection 1000BaseSx, 1000 Mbit, multi-mode, intrinsically safe (Ex op is) (not ET-6x7) Multi-mode optical fibre cable (50 µm core cross section and 125 µm external cross section) Single-mode optical fibre cable (9 µm core cross section and 125 µm external cross section) 2x Ex-ia; 1x Ex-e For keyboard and mouse (Ex-ia) RS-232, (Ex-e) FBAS (Ex-e) Line In/Out interface (Ex-e) (Line-in only for ET-6x7) Optical fibre SM Copper (TX) for DVI1 CAT for DVI2 CAT for DVI3 CAT Enclosure Enclosure protection type Permitted ambient temperature range Operating temperature range Cold start temperature Operation Permanent operation Short-term operation Storage temperature range Operating temperature range for DVI1 Cold start temperature Operation Permanent operation Storage temperature range Heat dissipation Relative humidity for DVI1 Dimensions [mm] (inch) Front (w x h) Cut-out (w x h) (+/- 0.5) (0.002") Depth of cut-out Wall thickness Mounting position: Weight [kg] (lb) HMI device up to 500 m (1,640 ft) via 50/125 μm optical fibre cable, up to 300 m (985 ft) via 62.5/125 μm optical fibre cable up to 10,000 m (33,000 ft) via 9/125 μm optical fibre cable up to 100 m (330 ft) via CAT7 installation cable AWG 22 up to 140 m (460 ft) via CAT7 installation cable AWG 22 up to 500 m (1,640 ft) via CAT7 installation cable AWG 22 up to 150 m (492 ft) via CAT7 installation cable AWG 22 Stahl Front IP66, back side IP65 - 30°C … + 60°C - 10°C … + 50°C - 20°C … + 60°C - 20°C … + 50°C - 30°C … + 60°C for a maximum of 5 h - 30°C … + 70°C + 5°C … + 40°C + 5°C … + 40°C + 5°C … + 40°C - 20°C … + 70°C about 40% via the front plate and 60% via the enclosure 10 to 90% at 40°C, non-condensing 20 to 80% at 40°C, non-condensing 660 x 475 (25.98” x 18.70”) 615 x 435 (24.21” x 17.13”) 110 (4.33") ≤ 5 (0.02") vertical or horizontal 32.00 (70.55 lb) R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 7 of 32 Series ET-xx7 4.1 Conformity to standards In addtion to ET-4x7 (Panel PC) Processor Working memory [GB] Data memory [GB] ATOM 1.6 GHz 1/2 4 / 16 128 GB MLC 128 GB SLC Type of data memory Standard Optional Operating system: Standard Software Global language support 5 SSD solid state flash drive Extension to Exicom-SHD-xxx hard disk. 100 GB instead of flash memory Windows XP embedded Windows XP Professional Windows 7 Ultimate WIN CC flexible, iFix, RSView (for further software solutions, please refer to our homepage) Via Multi-Language interface of Windows XP embedded (25 languages) Conformity to standards The ET-xx7 HMIs comply with the following standards and directives: Standard Classification Directive 94/9/EC 2. Supplement EN 60079-0 : 2009 General requirements IEC 60079-0 : 2007 IEC/EN 60079-5 : 2007 Powder filling »q« EN 60079-7 : 2007 Increased safety "e" IEC 60079-7 : 2006 EN 60079-11 : 2007 Intrinsic safety "i" IEC 60079-11 : 2006 EN 60079-26 : 2007 Device protection (EPL) "Ga" EN 60079-28 : 2004 Optical radiation IEC 60079-28 : 2006 EN 60079-31 : 2009 Protected by enclosures "tD" (dust) IEC 60079-31 : 2008 EN 61241-11 : 2006 Intrinsic safety "i" IEC 61241-11 : 2005 Electromagnetic compatibility directive 2004/108 EC EN 61000-6-2 : 2006 Interference resistance EN 61000-6-4 : 2007 Interference emission Low voltage directive directive 2006/95 EC EN 50178 1997 : Fitting power plants with electronic equipment EN 61010-1 : 2001+ General requirements Page 8 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 6 Certificates Certificates The ET-xx7 HMIs are certified for installation in the following areas: Europe: According to ATEX Directive 94/9/EC for installation in zones 1, 2, 21 and 22. International: IECEx (International Electrotechnical Commission System for Certification to Standards for Electrical Equipment for Explosive Atmospheres) Asia: GOST-R (Russian certificate) KGS (Korea Gas Safety Corporation) 6.1 ATEX The ATEX certificate is listed under the following certification number: Certificate number: 6.2 BVS 11 ATEX E 102 X IECEx The IECEx certificate is listed under the following certification number: Certificate number: IECEx TUR 11.0075X All IECEx certificates are listed on the IEC's official website under their certification number. http://iecex.iec.ch/iecex/iecexweb.nsf/welcome?openform. 6.3 GOST-R The GOST-R certification is listed under the following certification number: Certificate number: 6.3.1 Operating licence Number: 6.4 РОСС DE.ГБ04.B01882 PPC 00-048723 KGS The KGS certification is listed under the following certification number: Certificate number: 12-GA4BO-0617X NB: In order to be able to operate these HMIs in Korea, each device type additionally requires a KCC certificate. Actually the following devices has such a certificate: T-Ex-22 (ET-x67), T-Ex-24T (ET-x77 with Touch screen (foil)) R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 9 of 32 Series ET-xx7 7 Marking Marking Manufacturer R. STAHL HMI Systems GmbH Type code ET-xx7 CE classification: c 0158 Testing authority and certificate number: BVS 11 ATEX E 102 X Ex classification: ATEX guideline 94/9/EC IECEx e II 2(1) G Ex e q [ia op is Ga] IIC T4 Gb II 2(1) D Ex tb IIIC [ia op is Da] IP65 T110°C Db Ex e q [ia op is Ga] IIC T4 Gb Ex tb IIIC [ia op is Da] IP65 T110°C Db GOST-R 1Ex e q [ia op is Ga] IIC T4 Gb Ex tb IIIC [ia op is Da] IP65 T110°C Db KGS Ex e q IIC T4 Ex tb IIIC IP64 T110°C Ex ia IIC T4 Ex ia IIIB T110°C Page 10 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 8 8.1 Power supply HMIs Power supply: Max. power consumption: 9 9.1 Power supply 24 VDC or 100 – 240 VAC, 50 – 60 Hz at 24 VDC 3A at 100 - 240 VAC 1A Permitted maximum values External, non-intrinsically safe circuits Input voltage “PWR” (X10): Nominal voltage: Power consumption Imax Power Pmax Max. operating voltage Um Short-circuit current IK 20 ...240 V AC/DC (depending on type) ≤5A ≤ 150 W ≤ 250 VAC ≤ 1500 A USB (X13): Rated voltage Max. operating voltage Um 5 VAC/VDC (± 10%) ≤ 250 VAC 12 V (X14): Rated voltage Power consumption Imax Max. operating voltage Um 12 VAC/VDC (± 10%) ≤ 400 mA ≤ 250 VAC RS-232 "SER" (X97): Rated voltage Max. operating voltage Um 15 VAC/VDC (± 10%) ≤ 250 VAC Video "CAM" (X101): Rated voltage Max. operating voltage Um 5 VAC/VDC (± 10%) ≤ 250 VAC Audio "AUD" (X105): Rated voltage Max. operating voltage Um 100 VAC/VDC (± 10%) ≤ 250 VAC Copper Ethernet (CAT7 1) (X16): Rated voltage Max. operating voltage Um 5 VAC/VDC (± 10%) ≤ 250 VAC R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 11 of 32 Series ET-xx7 9.2 Permitted maximum values External inherently safe optical interface Ethernet optical fiber (FO 1) (X18) Multi-mode Wavelength Radiant power max. radiant power: 850 nm 0.22 mW 35 mW Single mode Wavelength Radiant power max. radiant power: 9.3 1310 nm 0.22 mW 35 mW External intrinsically safe circuits Keyboard (X11) The maximum values are: Ui = 5.5 Ii = 3 Pi = 2 Ci = negligible Li = negligible V A W µF mH Uo lo Po Co Lo = = = = = 5.5 309 629 50 40 V mA mW µF µH V A W µF mH Uo lo Po Co Lo = = = = = 5.5 309 629 50 40 V mA mW µF µH V A W µF mH Uo lo Po Co Lo = = = = = 5.5 309 629 50 40 V mA mW µF µH V A W µF mH Uo lo Po Co Lo = = = = = 5.5 309 629 50 40 V mA mW µF µH Pointer device (X12): The maximum values are: Ui = 5.5 Ii = 3 Pi = 2 Ci = negligible Li = negligible USB1i (X24): The maximum values are: Ui = 5.5 Ii = 3 Pi = 2 Ci = negligible Li = negligible USB2i (X25): The maximum values are: Ui = 5.5 Ii = 3 Pi = 2 Ci = negligible Li = negligible Page 12 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Type code 10 Type code 10.1 Panel PC ET-4x7 ET-4x7-aa-bb-cc-dd-ee-ff-gg-hh Front design Outdoor option Power supply Data memory Main memory Touch screen Display type Ethernet interface 467 / 477 / 487 middle digit = display size 6 = 56 cm/22" Display 7 = 61 cm/24" Display 8 = 61 cm/24"WU Display Product type: Product key structure ET-4x7-SX-bb-cc-dd-ee-ff-gg-hh ET-4x7-TX-bb-cc-dd-ee-ff-gg-hh ET-4x7-aa-TFT-cc-dd-ee-ff-gg-hh ET-4x7-aa-bb-T-dd-ee-ff-gg-hh ET-4x7-aa-bb-TG-dd-ee-ff-gg-hh ET-4x7-aa-bb-cc-R1-ee-ff-gg-hh ET-4x7-aa-bb-cc-R2-ee-ff-gg-hh ET-4x7-aa-bb-cc-dd-4GB-ff-gg-hh ET-4x7-aa-bb-cc-dd-16GB-ff-gg-hh ET-4x7-aa-bb-cc-dd-128GBM-ff-gg-hh ET-4x7-aa-bb-cc-dd-128GBS-ff-gg-hh ET-4x7-aa-bb-cc-dd-100GB-ff-gg-hh ET-4x7-aa-bb-cc-dd-ee-AC-gg-hh ET-4x7-aa-bb-cc-dd-ee-DC-gg-hh ET-4x7-aa-bb-cc-dd-ee-ff-O30-hh ET-4x7-aa-bb-cc-dd-ee-ff-gg-AL ET-4x7-aa-bb-cc-dd-ee-ff-gg-RM Description Type with Optical fiber Ethernet interface 1000BaseSx (Ex op is), multi-mode Copper Ethernet interface 10/100BaseTx (Ex-e) TFT display (standard) Touch screen (foil) Touch screen glass Working memory 1 GB Working memory 2 GB 4 GB Solid State Drive 16 GB Solid State Drive 128 GB Solid State Drive MLC 128 GB Solid State Drive SLC 100 GB hard disk (internal) Power supply 100 - 240 VAC, 50 - 60 Hz Power supply 24 VDC Outdoor installation -30°C Aluminium front plate Rear-mounted module R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 13 of 32 Series ET-xx7 10.2 Type code Remote HMI Thin Client ET-5x7 ET-5x7-aa-bb-cc-dd-ee-ff Front design Outdoor option Power supply Touch screen Display type Ethernet interface 567 / 577 / 587 middle digit = display size 6 = 56 cm/22" Display 7 = 61 cm/24" Display 8 = 61 cm/24"WU Display Product type: Product key structure ET-5x7-SX-bb-cc-dd-ee-ff ET-5x7-TX-bb-cc-dd-ee-ff ET-5x7-aa-TFT-cc-dd-ee-ff ET-5x7-aa-bb-T-dd-ee-ff ET-5x7-aa-bb-TG-dd-ee-ff ET-5x7-aa-bb-cc-AC-ee-ff ET-5x7-aa-bb-cc-DC-ee-ff ET-5x7-aa-bb-cc-dd-O30-ff ET-5x7-aa-bb-cc-dd-ee-AL ET-5x7-aa-bb-cc-dd-ee-RM Page 14 of 32 Description Type with Optical fiber Ethernet interface 1000BaseSx (Ex op is), multi-mode Copper Ethernet interface 10/100BaseTx (Ex-e) TFT display (standard) Touch screen (foil) Touch screen glass Power supply 100 - 240 VAC, 50 - 60 Hz Power supply 24 VDC Outdoor installation -30°C Aluminium front plate Rear-mounted module R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 10.3 Type code Remote HMI KVM ET-6x7 ET-6x7-aa-bb-cc-dd-ee-ff Front design Outdoor option Power supply Touch screen Display type Transfer technology 667 / 677 / 687 middle digit = display size 6 = 56 cm/22" Display 7 = 61 cm/24" Display 8 = 61 cm/24"WU Display Product type: Product key structure Description Type with ET-6x7-DVI1-CAT-bb-cc-dd-ee-ff DVI1 KVM, with direct copper connection Gigabit (Ex-e) ET-6x7-DVI1-MM-bb-cc-dd-ee-ff DVI1 KVM, with direct optical fibre connection (Ex op is), multi-mode ET-6x7-DVI1-SM-bb-cc-dd-ee-ff DVI1 KVM, with direct optical fibre connection (Ex op is), single-mode ET-6x7-DVI2-CAT-bb-cc-dd-ee-ff DVI2 KVM, with direct copper connection Gigabit (Ex-e) ET-6x7-DVI3-CAT-bb-cc-dd-ee-ff DVI3 KVM, with direct copper connection Gigabit (Ex-e) ET-6x7-DVI3-MM-FO-bb-cc-dd-ee-ff DVI3 KVM, with direct optical fibre connection (Ex op is), multi-mode ET-6x7-DVI3-SM-FO-bb-cc-dd-ee-ff DVI3 KVM, with direct optical fibre connection (Ex op is), single-mode ET-6x7-aa-TFT-cc-dd-ee-ff TFT display (standard) ET-6x7-aa-bb-T-dd-ee-ff Touch screen (foil) ET-6x7-aa-bb-TG-dd-ee-ff Touch screen glass ET-6x7-aa-bb-cc-AC-ee-ff Power supply 100 - 240 VAC, 50 - 60 Hz ET-6x7-aa-bb-cc-DC-ee-ff Power supply 24 VDC ET-6x7-aa-bb-cc-dd-O30-ff Outdoor installation -30°C ET-6x7-aa-bb-cc-dd-ee-AL Aluminium front plate ET-6x7-aa-bb-cc-dd-ee-RM Rear-mounted module R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 15 of 32 Series ET-xx7 Safety information 11 Safety information 11.1 General Safety Information • All relevant accident prevention regulations and the rules for electric installations have to be observed during installation, maintenace and operations. All persons involved in installation, commission, maintenance and repairs of this device and its accessories must be qualified accordingly and must have familiarised themselves with this manual and any associated documentation. • In case of non-compliance or contravention of the above explosion-protection is no longer guaranteed and all warranty claims shall be null and void. • National safety and accident prevention rules apply. • Use the device for its intended purpose only. • No changes to the device are permitted. The enclosure may only be opened by R. STAHL HMI Systems GmbH. • The first four digits of the serial number on the type plate stand for the year of manufacture. 11.2 Warning Warning ! This is an EN 55022 Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 11.3 Safety information for installation • The national assembly and installation rules and the generally accepted technical rules must be observed. The device and its accessories must be connected and operated according to applicable standards, directives and installation guidelines. Only qualified personnel or personnel that has been instructed accordingly are allowed to install the device. • Only appropriate tools must be used for the installation. • The screws on the lid of the Ex-e connection box must be fastened with a torque of 1 N. • The cable connections of the connection box must be in line with country-specific regulations and may have to be adapted accordingly. Potential changes to the ambient parameters such as temperature must be taken into account. • The cable entries in the connection box must have ingress protection IP 66 or may have to be adapted to meet country-specific requirements. The pre-assembled cable entry threads are size M16x1.5 and M20x1.5. The wall of the terminal box where the cable entries are mounted has a thickness of at least 4 mm. • The cable connections must be tightened fast according to regulations. Unused cable connections must be sealed with appropriate blind plugs. Only permanently laid cables may be connected to the pre-mounted ATEX cable connections. Page 16 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Safety information • The outer cable diameters must correspond to the cable connection specifications. Cable entry M16 for round cable, outside cable cross-section 5...9 mm (0.2"...0.35") Cable entry M20 for round cable, outside cable cross-section 9...13 mm (0.35"...0.51"). • The device must not be opened, maintained or repaired in hazardous atmospheres (sole exception: the Ex-e connection box). • Before opening the Ex-e connection box, ensure that all Ex-e and Ex-i circuits are fully deenergised and isolated. You must also ensure that the power supply circuit is isolated. The cable diameter must meet the terminal specifications. The Ex-e connection box must be tightly sealed. • All Ex-e and Ex-i circuits must be completely de-energised before the device is connected. After the Ex-e and Ex-i circuits have been de-energised, wait for at least seven minutes before opening the Ex-e connection box. The Ex-e connection box must not be opened if the device is energised. • The wire used for earthing must have a minimum cross section of 4mm² ! Make sure that there is equipotential bonding between the devices. • We recommend you use screened cables with the device. Routing of the data cable may reduce performance. Cables for intrinsically safe wiring have to pass a test voltage of AC 500 V/DC 750 V. Use the values 200 pF/m and 1 μH/m at unknown cable properties. • If display types ET-xx7-DVI1-MM or ET-xx7-DVI1-SM are used, terminal X16 remains unused. • To establish a secure earthed connection between device and plant and to prevent inadvertent loosening of the cables, each cable with its screen must be connected to the corresponding earthing bracket located in the Ex-e connection box close to the associated terminal. • At the place of installation voltage must not exceed 250 V and short-circuit current must not exceed 1500 A. • A tick close to the X10 terminal indicates the voltage type (AC/DC). For the 24 VDC types the cable cross-sections depend on the cable length of the voltage supply cable, as follows: Cable length in metres (ft) Cable cross-section in mm² (AWG) max. 55 m (180 ft) 1.5 mm² (AWG 16) max. 90 m (295 ft) 2.5 mm² (AWG 14) max. 150 m (492 ft) 4 mm² (AWG 12) max. 225 m (738 ft) 6 mm² (AWG 10) max. 375 m (1230 ft) 10 mm² (AWG 8) max. 600 m (1968 ft) 16 mm² (AWG 6) If the cable's cross section is greater than the maximum possible for the terminals, the cable needs to be routed according to regulations via a smaller cable cross section before being inserted into the connection box (possibly using the Ex-e terminal box). R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 17 of 32 Series ET-xx7 Safety information • When the interface of intrinsically safe devices/partial intrinsically safe devices was or is connected to not intrinsically safe interfaces, the license will become void and it must be operated as a not intrinsically safe device. If the device was operated on an intrinsically safe interface with a lower level of international protection (e.g. a Ex ia device on a Ex ib interface), it must not be operated afterwards in applications for a higher level of international protection (e.g. Ex ia). • If the device is being used in a dust atmosphere and must be replaced, the device or the enclosure in which it is mounted must be disconnected from the mains first and then, according to regulations, be left to cool down. Before opening the device or its enclosure and whilst they are open, the environment must be kept dust-free so that no dust can intrude into the inside of the enclosure. When mounting new components please ensure that all seals are undamaged and fit tightly. • Before starting up the device you must ensure that it has been installed according to regulations and that neither the device nor its cables are damaged. 11.3.1 HMI device installation in housings type of protection "e" or "t" If the HMI devices ET-xx7 are mounted inside a cut out of a suitable housing of protection type Ex-e or Ex-t, its mechanical protection regarding impact and IP code protection up to IP 65 is maintained even after the device has been installed. The internal separation requirements and the temperature assessment of the Ex-e housing must be in accordance with the applicable standards. The clearance of operator panel terminals to other bare conducting parts (excepting ground) inside the Ex-e housing shall be at least 50 mm. 11.4 Safety information for operation • Operate the device only if it is clean and undamaged. If the device is in any way damaged, do not touch it to avoid injury. In the case of any damage that may compromise ingress protection (e.g. cracks, holes or broken components) the device must be taken out of commission immediately. Before the device is recommissioned the damaged components must be replaced. • If you want to use the device in category 1D/2D/3D or EPL Da/Db/Dc, dust deposita of a thickness exceeding 5 mm must be removed and you have to ensure that no high-energy loading mechanisms at the operating surface of the unit (e.g. pneumatic particle transport) occur during operation. The device may not be used in environments where propagating brush discharges may occur. • In general, and particularly when opening and closing enclosures, users must take care not to get injured by getting caught / trapped. • In case of non-compliance or contravention of the above explosion-protection is no longer guaranteed and all warranty claims shall be null and void. 11.5 Special conditions Equipotential bonding must be established for the external intrinsically safe circuits of the accessories to be connected, e.g. display, keyboard or pointer device. Page 18 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Assembly and disassembly 12 Assembly and disassembly 12.1 General information Assembly and disassembly are subject to general technical rules. Additional, specific safety regulations apply to electronic and pneumatic installations. In Germany, for example, these include the BG regulations (Government Safety Association) and the BetrSichVer (Betriebsicherheitsverodnung - Occupational Health and Safety). 12.2 Cut-out ET-xx7 Make a cut-out with the following dimensions: Width 615 ± 0.5 mm 24.21" ± 0.002" Height 435 ± 0.5 mm 17.13" ± 0.002" Depth of cut-out Material thickness 110 mm up to 5 mm 4.33" up to 0.02" 13 Operation 13.1 General information When operating the devices, particular care shall be taken that: • • • • • the HMI has been properly installed according to instructions, the HMI is undamaged, the terminal compartment is clean, all screws are tightened fast, before switching the HMI on, its external PE terminal is properly connected to the equipotential bonding system at its place of use, • the cover of the terminal compartment is completely closed. R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 19 of 32 Series ET-xx7 13.2 Operation Connections Terminal Pin Definition / typcial cable colour X10 1 Power supply HMI +24 VDC or 100 - 240 VAC PWR 2 Power supply HMI 0 VDC or 100 - 240 VAC 3 Earth HMI X11 1 +UB Red KBi 2 DWhite 3 D+ Green 4 GND Black X12 1 +UB Red Mi 2 DWhite 3 D+ Green 4 GND Black X13 1 +UB Red 2 DWhite 3 D+ Green 4 GND Black X14 1 +12 V Red 2 GND Black X16 1 TRD0+ White / Orange CAT7 1 2 TRD0Orange Data 3 TRD1+ White / Green 4 TRD1Green 5 TRD2+ Blue / White 6 TRD2Blue 7 TRD3+ White / Brown 8 TRD3Brown 9 SHLD Screen X18 optical fibre connection FO 1 type LC Data Duplex connector Tx X24 USB1i X25 USB2i X97 SER Page 20 of 32 1 2 3 4 1 2 3 4 1 2 3 4 5 +UB DD+ GND +UB DD+ GND TxD RxD RTS CTS GND Connection Power supply of the HMI Ex-e USB interface Ex ia for external keyboard USB interface Ex ia for mouse USB Ex-e 12 VDC output Ex-e Ethernet copper connection * Ex-e Ethernet optical fibre interface * Ex op is Rx Red White Green Black Red White Green Black Blue / White Blue White / Orange Orange Black USB interface Ex ia USB interface ** Ex ia Serial Ex-e interface RS-232 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 X101 CAM X105 AUD * ** 1 2 1 2 3 4 5 Operation FBAS GND CH1 / line out left CH2 / line out right CH3 / line in left CH4 / line in right GND White Black Red Black Red Black Black Video Ex-e interface Audio Ex-e interface The following applies to all terminals: 0.2 - 2.5 mm² / 24 AWG - 16 AWG for flexible cable 0.2 - 4 mm² / 24 AWG - 14 AWG for rigid cable Strip cable of 7 mm (0.28 in) insulation max. one cable per terminal recommended cable length for terminals X11, X12, X13, X14, X24, X25: max. 3 m (10 ft) Please note that the Ethernet connection is either for an optical fibre connection (X16) or for a copper connection (X18), depending on the version ordered ! If display types ET-xx7-DVI1-MM or ET-xx7-DVI1-SM (optical fibre versions) are used, terminal X16 remains unused. In the case of an optical fibre connection the following cable is recommended: Multi-mode FO cable: 50 µm core cross section and 125 µm external cross section Single-mode FO cable: 9 µm core cross section and 125 µm external cross section The USBi2 connection (X25) is NOT available for devices with touch screen and may NOT be connected ! R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Page 21 of 32 Series ET-xx7 Maintenance 14 Maintenance Because the transmission of the devices remains reliable and stable over long periods of time, regular adjustments are not required. Keep the units clean so that the enclosure locks and screws remain accessible. Maintenance may be required for the enclosure seal. System maintenance should focus on the following: a. Seal wear b. Display damage c. All screws are tightened fast d. All cables and lines are properly connected and undamaged 15 Troubleshooting Devices operated in hazardous areas must not be modified. Repairs may only be carried out by qualified, authorized staff specially trained for this purpose. Repairs may only be carried out by specially trained staff who are familiar with all basic conditions of the applicable user regulations and – if requested – have been authorized by the manufacturer. 15.1 Repairs / hazardous substances An error description must be enclosed with any units returned to R. STAHL HMI Systems GmbH for repairs. Remove all material residues. Please pay particular attention to the seal grooves and slits where material residues may be lodged. We have to ask you not to return a unit if you are unable to completely remove any hazardous substances. We shall bill you for any costs arising from insufficiently cleaned units, such as disposal or damage to persons (chemical burns, etc.). 16 Disposal Disposal of packaging and used parts is subject to regulations valid in whichever country the device has been installed. The disposal of devices sold after August 13th, 2005, and installed in countries under the jurisdiction of the EU is governed by directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Under this directive, HMIs are listed in category 9 (monitoring and control instruments). We shall take back our devices according to our General Terms and Conditions. 16.1.1 ROHS directive 2002/95/EC The prohibition of hazardous substances as detailed in directive 2002/95/EC (ROHS) does not apply to electronic equipment of categories 8 and 9, and is therefore not applicable to the equipment described in these operating instructions. Page 22 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Front panel resistance 17 Front panel resistance This section contains information on the resistance of the HMIs to various environmental factors. These have an impact on the mechanical, thermal and chemical stability of the HMIs. The resistance to chemicals was tested according to DIN 42115 Part 2, i.e. the stability over 24 hours without visible changes to the HMIs. 17.1 Materials Application Front plate Touch screen Enclosure Front panel seal 17.1.1 Material Aluminum Polyester Stainless steel Polyurethane Material properties The selection of chemicals listed here is not exhaustive. 17.1.2 Touch membrane (polyester) Property Chemical • Chemical resistance Chemical material class / group Alcohols Aldehydes Amines Esters Chemical substances 1,3 Butanediol 1,4 Butanediol Cyclohexanol Diacetone alcohol Ethanol Glycol Glycerol Isopropyl alcohol Methanol Neopentyl glycol Octanol 1,2 Propylene glycol Triacetin Dowandol DRM/PM Acetaldehyde Formaldehyde 37-42% Ammonia <2% Amyl acetate Ethylacetate N-Butyl acetate R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Test method DIN 42115 DIN 53 461 or ASTM-F-1598-95 Page 23 of 32 Series ET-xx7 Front panel resistance Ethers 1.1.1. Trichloroethane Ether Dioxane Diethyl ether 2-Methyltetrahydrofuran (2-ME-THF) Aromatic hydrocarbons Benzene Toluene Xylene Paint thinner (white spirit) Ketones Acetone Methyl ethyl ketone Cyclohexanone Methyl isobutyl ketone (MIBK) Isophorone Diluted acids Formic acid <50% Acetic acid <5% Phosphoric acid <30% Hydrochloric acid <10% Nitric acid <10% Trichloroacetic acid <50% Sulfuric acid <30% Diluted alkaloids Caustic soda <40% (bases) Household chemicals Ajax Ariel Domestos Downey Fantastic Formula 409 Gumption Jet Dry Lenor Persil Tensides Top Jop Vim Vortex Washing powder Fabric conditioner Whis Windex Oils Petrol Drilling muds Braking fluid Decon foam Diesel oil Varnish Keroflux Paraffin oil Castor oil Silicone oil Solvent naphta Mineral turpentine Kerosene Page 24 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 Front panel resistance No specific material class Property Mechanic (keyboard) • durability • Action power • MIT folding resistance Mechanic (touch screen) • point activation Thermal • Dimensional • Dimension stability Acetonitrile Alkali carbonate Dichromates Potassium dichromate Caustic soda <20% Dibutyl phthalate Dioctyl phthalate Iron II chloride (FeCl2) Iron II chloride (FeCl3) Haloalkanes Potassium soap Potassium hydroxide <30% Sodium bisulfate Tetrachloroethylene Salt water Trichloroethylene Water Hydrogen peroxide >25% Resistance Test method >1 million actions max. 50 N Autotype method ASTM D2176 >20000 folding operations 3M method 1 million activations at any single point Max. 0.2% at 120° longitudinal Typically 0.1% R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Autotype method Page 25 of 32 Series ET-xx7 Declaration of EC conformity 18 Declaration of EC conformity Page 26 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Series ET-xx7 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 Declaration of EC conformity Page 27 of 32 Series ET-xx7 Release notes 19 Release notes The chapter entitled "Release Notes" contains all the changes made in every version of the operating instructions. Version 1.02.00 • Original version of the operating instructions • Changing name from T-Ex to ET-xx7 • DVI3 included Version 1.02.01 • • • • • • • Formal corrections Changings in preface Addition of IEC in conformity to standards Addition of KGS and KCC in certificates Removing of all information to 19" devices Changes in type code Addition of information to "device installation in housings type of protection "e" or "t"" Page 28 of 32 R. STAHL HMI Systems GmbH / OI_ET_xx7_en_V_01_02_01.docx / 23.07.2013 R. STAHL HMI Systems GmbH Im Gewerbegebiet Pesch 14 D-50767 Köln Telephone: (switchboard) +49/(0)221/ 5 98 08 - 200 (Hotline) - 59 Fax: - 260 E-mail:[email protected] (otline) [email protected] ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Explosion-protected
- Operable in zones 1 and 21
- Interfaces for zones 0/1/2 and 20/21/22
- Serial interfaces (RS-232, Ethernet)
- USB interfaces
- Powerful processors
- Back-up and recovery system
- Thin Clients or KVM box via KVM-over-IP
- Multi-monitoring with several on-site terminals
- DVI1, DVI2 and DVI3 transfer technologies
Frequently asked questions
These HMIs can be operated in zones 1 and 21 with interfaces for zones 0/1/2 and 20/21/22.
The devices are connected to a communication system via the serial interfaces (RS-232, Ethernet) located in their connection box at the rear.
The connection box also contains the USB interfaces for the connection of various peripheral devices. Furthermore, the interfaces for keyboard, mouse, video and audio signals are also located here.