Brochure - Industrial Hot Water Solutions

Brochure - Industrial Hot Water Solutions
Industrial Hot
Water Solutions
Flo-Direct®
Complete Thermal Exchange Gas Fired Water Heater
Ultra low Nox option available ≤ 9 ppm
Standard Low Nox (30-50ppm)
high-efficiency burner/blower for low
carbon monoxide and nitrous oxide
emissions. Complies with even the
most stringent emission standards
and is an ideal element for companies
seeking to reduce their overall carbon footprint.
Water pressure limit switch and high
temperature switch shut down
the unit for safety if water pressure
fails or is accidentally shut off.
Exhaust temperatures within a few degrees
of the incoming water allow for inexpensive
CPVC or single-wall stainless for ducting
materials.
CTE compliant for enhanced water
purity and safety.
Electrical programmable logic controller
(PLC). NEMA 4 - IP 65
(watertight) enclosure; modular
components for easy service or
replacement. Status lights for easy
troubleshooting.
10 gauge stainless steel construction
with a 10-year warranty on the
structure and its internals. 2-year
warranty on external components.
Indexability of the top portion to the
bottom allows for flexibility in rotating
for easiest utility hookups. Allows for
ease of internal inspection.
Level controls automatically
control the transfer pump
(included) which delivers
heated water to application.
Flo-Direct is U.S. Patent 5,924,391
Modular fuel train using slide out
components for ease of maintenance
or replacement. CSA, ETL, CTE and
FM compliant. CE approved
according to PED (97/23/EC)
Flo Direct Complete Thermal Exchange
Gas Fired Water Heaters are fully
compliant and correctly identified as
required by the relevant CE marking
regulations.
This includes:
• Low Voltage Directive (2006/95/EC)
• EMC Directive (2004/108/EC)
• Machinery Directive (98/37/EC)
• Gas Directive (90/396/EC)
Refer to page 13 for more information.
Small footprint because the burner
is installed on top of the unit
“out of the way” and not on the side.
No side clearance required.
For additional information and to view our educational video, visit: armstronginternational.com/flo-direct
2
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Flo-Direct®
Complete Thermal Exchange Gas Fired Water Heater
Armstrong Flo-Direct CTE gas fired water heaters offer a
complete range of high efficiency, compact, all stainless steel
water heaters which are remarkably dependable, simple in
design and operation, and suitable for a wide variety of hot water
applications.
Flo-Direct Complete Thermal Exchange Gas-Fired
Water Heaters deliver unrivaled Performance and
Efficiency.
The Flo-Direct CTE gas fired water heaters often deliver fuel
savings as high as 30-60% when compared to steam/water
heating systems. Standard operating capacities are between 1
million and 16 million BTU per hour.
Incoming water is introduced into the top of the water heater
through a series of calibrated dispersion nozzles. Cold water
travels down through a bed of multifaceted stainless steel
packing rings (Pall Rings) which break the water into smaller
and smaller droplets.
With a small footprint, 99.7% or greater high heat value
(110% low heat value) heat transfer efficiencies*, remarkable
dependability, ease of maintenance, and the ability to operate
well with poor water quality, Armstrong Flo-Direct CTE gas fired
water heaters are the product of choice for companies seeking
to achieve Energy Conservation Measure (ECM) and Reduced
Carbon Footprint objectives.
A burner is mounted on top of the unit, firing downward through
a centrally located flame tube. The flame tube is cooled by
incoming cold water, and all of the fuel gasses are consumed
within this flame tube. The design allows all combustion to take
place within a dry and cool environment, and produces very low
levels of nitrous oxide (NO) and carbon monoxide (CO).
Primary Markets include:
Heat from the flame enters the lower chamber from the bottom
of the flame tube, and travels slowly upward through the packing
rings. Efficient heat transfer occurs as the descending water
comes in contact with the rising hot gasses as both pass through
the bed of packing rings in opposite directions.
Food Process Industries
• Washdown
• Batch Production
• Vessel Filling
• Tank Cleaning
• Bottle Warming
Concrete Plants
• Pre-Heated Water for batch production
Space Heating
• Greenhouses
Re-Circulated HW for general space heating
• Light Manufacturing/Warehouses
Re-Circulated HW for general space heating
General Industry
• Boiler Make-Up Water
Customized Hot Water System Solutions are our specialty.
Multiple orientations, configurations and options are available.
Hot Water System Solutions which include transfer pumps,
storage tanks variable frequency drive (VFD) pump skidpackaged solutions, hose stations, circulating pumps,
downstream digital water temperature controls/loops with BAS/
DDC interface along with a multitude of performance matched
components can be application engineered specifically to meet
the projects requirements.
Additionally, where appropriate, Armstrong can integrate
engineering services, turn key installation, project management,
system assessment and optimization along with energy
conservation measure (ECM) capability through Armstrong
Service Incorporated.
This “rain” of hot water then falls into the lower chamber and is
pumped out to a storage tank. Water temperatures up to 185ºF
are available within two minutes after the unit starts.
Outlet water temperature is set with a value controlling the
incoming water flow. More incoming water results in cooler outlet
water temperatures, and less incoming water produces hotter
outlet water temperatures.
The products of combustion are vented out of the top of the unit,
and this exhaust is typically within a few degrees of incoming
water temperature.
Features
• CTE Compliant
• Meets multiple global water quality standards (page 4)
• No internal moving parts
• Low-temperature exhaust
• 99.7% or greater high heat value efficiency
• Water treatment not required
• Stainless steel construction
• Takes up minimal floor space
• Ten year warranty on structure/two years on all other
components
Engineered Solutions
Armstrong can provide integrated engineering, turnkey
installation and project management services. Additionally,
Armstrong can perform system assessments and optimizations
and identify Energy Conservation Measures (ECMs).
*See page 10 for high heat value (HHV) and low heat value
(LHV) explanation.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
3
Flo-Direct®
Complete Thermal Exchange Gas Fired Water Heater
CTE Technology
Developed from direct contact water heating science which was
first introduced more than two decades ago, Complete Thermal
Exchange (CTE) technology has revolutionized high efficiency
water heating methods. Today CTE enjoys a proven record and
has rapidly become the new standard in high efficiency water
heating and energy savings.
While traditional direct contact water heating can offer significant
energy savings when compared to a conventional steam boiler
system, the Armstrong Flo-Direct CTE gas fired water heater
offers an unparalled, 99.7% high heat value (110% approx.
low heat value) efficiency rating* throughout each phase of its
operation cycle.
The sustained operational efficiency of Flo-Direct CTE gas fired
water heaters creates the most energy efficient method of hot
water production currently available.
No Scale Build-Up
The Flo-Direct CTE gas fired water heater’s unique design
prevents scale build-up because there are no “hot spots”
internally or externally, and because calcium is prevented from
completely falling out of suspension during operation. As a result,
the mineral content of the influent water and the effluent water
will be equal.
Armstrong Flo-Direct CTE gas fired water heaters
achieve CTE Standards
The Flo-Direct CTE direct contact water heaters, meet five
standards not available with the older designs and traditional
methods of direct contact water heater technology:
1. CTE units maintain a minimum of 99.7% high heat value
(110% approx. low heat value) efficiency in all modes of
operation, not just under optimal conditions.
Global Water Quality Standards
2. CTE units have multiple thermal passes. Water and the
combustion gasses (or heat from the combustion) repeatedly
come in contact. This ensures that the maximum amount of
heat or energy from combustion is transferred to the water.
Flo-Direct Complete Thermal Exchange (CTE) Gas Fired
Water Heating Technology significantly limits the effluent water
chemical additives typically attributed to other process water
heating systems.
3. CTE units have a dry combustion chamber. This is vital to
maintaining complete combustion at all times during operation.
4. CTE units maintain complete combustion at all times.
5. CTE units must have an integral water quality integrity system.
Operational procedures must be in place to ensure that
effluent water quality is equal to the influent water quality.
NSF test results show that the effluent water from a Flo-Direct
CTE Gas Fired Water Heater meets US, European Union and
PRC bottled drinking water standards* and has been tested and
documented as fully compliant with:
Complete Combustion = Complete Water Quality
• USFDA - The United States Food and Drug Administration,
Code of Federal Regulations Bottled Water Standard:
Chapter I, Title 21, Part 165, Subpart B, Section 165.110.
While many traditional-method direct contact water heaters spray
water directly on the flame – sometimes called “flame quenching”
– Flo-Direct, using CTE technology, avoids this process altogether.
According to the Industrial Heating Equipment Association’s
“Combustion Technology Manual,” flame quenching promotes
incomplete combustion, and produces alcohols, aldehyde, formic
acid, higher order acids, carbon monoxide, as well as carbon
dioxide and water vapor. With CTE technology, Flo-Direct maintains
99.7% high heat value* (110% approx. low heat value) combustion
efficiency, while maintaining water quality at all times.
*See page 10 for high heat value (HHV) and low heat value (LHV)
explanation.
4
Our unique CTE water heating process deaerates the water
significantly. Independent third party testing has verified CTE
technology can actually remove some chemical constituents
from the influent water.
• EU-TRW - The European Union Directives(s) - Treated
Waters: 98/83/EC.
* Peoples Republic of China Standards for Drinking Water:
GB5749-2006
*Statement presumes influent water also meets listed
standards.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Flo-Direct®
Complete Thermal Exchange Gas Fired Water Heater
Specifications
Materials
Gas Supply Pressure
2 - 6 psig / .14 - .41 bar
Upper and Lower Canister
Type 304 Stainless Steel #10 Glass Finish
Dynamic Water Supply
Pressure
Constant water pressure (+/-5 psi variation
maximum) within a minimum of 30 psig/2 bar
and a maximum of 100 psig/6.8 bar range is
required for optimum performance.
Inlet Gas Train Piping
Malleable Iron with Standard Yellow Finish
Inlet Water Train Piping
Copper with Brass/Bronze Fittings
Spray Ring
Type 304/316 Stainless Steel
Canister Gaskets
Warco White
Flame Tube
Type 304 Stainless Steel
Pall Rings
Type 304 Stainless Steel
Maximum Inlet Water
Temperature
120°F (49°C)
Minimum Inlet Water
Temperature
32°F (0°C)
Maximum Effective Outlet
Temperature
Optional/Custom materials of construction available upon request.
185°F (85°C)
Standard Sizing Formulas
Standard Formula Key
gpm x ∆T = AFD Model
2
gpm = Gallons per Minute
∆T
(AFD Model) x 2 = gpm
∆T
= Temperature rise (ºF)
AFD = Armstrong Flo-Direct
(e.g., 1000, 5000)
(AFD Model) x 2 = ∆T gpm
Use the Flo-Direct sizing tool at armstronginternational.com/flo-direct
Metric Sizing Formulas
Metric Formula Key
lpm x ∆T = AFD Model
4.2
lpm = Liters per Minute
∆T
(AFD Model) x 4.2 = lpm
∆T
= Temperature rise (ºC)
AFD = Armstrong Flo-Direct
(e.g., 1000, 5000)
(AFD Model) x 4.2 = ∆T lpm
Use the Flo-Direct sizing tool at armstronginternational.eu/flo-direct
For fully detailed certified drawing, refer to CDY #1088.
Flo-Direct Dimensions and Weights
Dimensions
Connections*
2
1
Model
A
B
C
D
Weight*
E
btu/hr
kW
375
1,000,000
292
386
1,500,000
439
1500
680
2,000,000
585
305
1600
725
3,000,000
878
14
356
2000
907
4,000,000
1171
16
406
2500
1136
5,000,000
1464
1194
18
457
2900
1316
6,000,000
1757
50
1270
18
457
3200
1455
7,000,000
2050
50
1270
18
457
3200
1455
8,000,000
2342
2718
60
1524
20
508
5000
2273
9,000,000
2635
119
3023
61
1549
20
508
5200
2405 10,000,000
2928
3835
119
3023
61
1549
22
559
5500
2495 11,000,000
3221
3835
119
3023
61
1549
22
559
5500
2495 12,000,000
3514
161
4089
129
3277
70
1778
24
610
7000
3175 13,000,000
3807
4877
161
4089
129
3277
70
1778
24
610
7000
3175 14,000,000
4099
192
4877
161
4089
129
3277
70
1778
24
610
7000
3175 15,000,000
4392
216
5486
185
4699
153
3886
70
1778
24
610
7500
3402 16,000,000
4685
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
lb
kg
1000
1
25
1
25
95
2413
71
1803
1500
1
25
1
25
97
2464
73
1854
39
991
24
610
8
203
825
41
1041
26
660
8
203
850
2000
1-1/2
40
1-1/2
40
100
2540
76
1930
44
1118
30
762
10-3/4
273
3000
2
50
1-1/2
40
100
2540
76
1930
44
1118
36
914
12
4000
2
50
2
50
104
5000
2-1/2
65
2
50
127
2642
80
2032
48
1214
40
1016
3226
97
2464
65
1651
44
1118
6000
3
80
2
50
132
3353
100
2540
70
1778
47
7000
3
80
2
8000
3
80
2
50
139
3531
107
2718
77
1956
50
139
3531
107
2718
77
1956
9000
3
80
2
50
169
4293
139
3531
107
10000
3
80
2
50
181
4597
151
3835
11000
12000
4
100
3
80
181
4597
151
4
100
3
80
181
4597
151
13000
4
100
3
80
192
4877
14000
4
100
3
80
192
15000
4
100
3
80
16000
4
100
3
80
All dimensions and weights are approximate. Use certified print for exact dimensions. Design and materials are subject to change without notice.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
5
Hot Water Systems
Flo-Direct Complete Thermal Exchange Gas Fired Water Heaters
deliver a wide variety of hot water solutions.
Non-Recirculating Hot Water Systems
Non-recirculating hot water systems are suitable for installations
which experience frequent demand or processes which can
accommodate the evacuation of a dead-leg before receiving
heater set point water temperatures.
Hose
Stations
Hot Water
Hot Water
Cold Water
Complete Thermal
Exchange Gas-Fired
Water Heater
Transfer Pump
Assembly
Hot Water
Storage
Variable Frequency
Drive Pump System
Recirculating Hot Water Systems
Recirculating hot water systems are suitable for installations
which experience diverse draw-off or processes which cannot
accommodate the evacuation of a dead-leg before receiving
heater set point water temperatures.
Return
Note: Recirculating hot water systems which idle at zero demand for
long periods or experience a radiant heat loss during recirculation
may require an immersion type heater in the storage tank.
Hose
Stations
Hot Water
Hot Water
Cold Water
Complete Thermal
Exchange Gas-Fired
Water Heater
6
Transfer Pump
Assembly
Hot Water
Storage
Variable Frequency
Drive Pump System
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Hot Water Systems
Multiple Temperature Hot Water Systems
MegaMix™ Water
Temperature Controller
Multiple temperature hot water systems can be designed as either
recirculating, non-recirculating or a combination of both. To achieve
multiple temperatures for the same hot water system, Armstrong
recommends one or more MegaMix™ electronic water temperature
controllers along with Armstrong thermostatic hot and cold water hose
stations.
MegaMix Water
Temperature Controller
Hot Water
Cold Water
MegaMix Water
Temperature Controller
To Process
Hot Water
Cold Water
Blended Hot Water
Blended
Hot Water
Hose
Stations
Batch of Vessel
Filling
Hot Water
Cold Water
Hot Water
Complete Thermal
Exchange Gas-Fired
Water Heater
Transfer Pump
Assembly
Hot Water
Storage
Variable Frequency
Drive Pump System
Armstrong Hot/Cold
Water Hose Station
Armstrong Variable Frequency Drive
Pump Assemblies
It is strongly recommended that
the hot water storage temperatures
are maintained at 140ºF (60ºC)
or higher in accordance with US
OSHA and CDC and corresponding
global legionella guidelines. If
water temperatures below 140ºF
(60ºC) are required, Armstrong
offers a variety of supplemental
thermostatic, electronic and digital
water temperature controllers.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
7
Packaged Hot Water Distribution Solutions
Variable Frequency Drive Pump Assemblies
The Armstrong Variable Frequency Drive (VFD) Pump
Packages team with our Flo-Direct CTE Water Heaters and
our optional storage tanks at a central location to maintain
flow and pressure levels at variable usage draw-off points
within the hot water distribution system.
Standard and custom designed assemblies are application
engineered and configured specifically to the needs of the
installation site to provide a complete high efficiency low
energy consumption hot water solution.
Precision Mixed Water Flow & Temperature Control
MegaMix™ Water Temperature Mixing Unit
MegaMix 3-port mixing valves utilize ceramic shear action disc
technology to provide tight shut-off, high pressure differential capability,
and a long service life.
Fitted with an electronic actuator and integral temperature sensor,
MegaMix delivers high-performance stand-alone temperature control
with ± 1ºF (± 0.5ºC) accuracy over a 32ºF to 212ºF (0ºC to 100ºC)
setpoint range.
MegaMix Water Temperature Mixing Units offer:
• Five Models
• On-board keypad for valve operation
• Flow capacities up to 1000GPM/3800LPM
• Operating inlet temperature range: -13ºF to 257ºF (-25ºC
to 125ºC).
• Analog (4-20mA) input and output control signals.
• Software configurable control settings
• 316 Stainless Steel construction
8
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Water Temperature Control for Emergency Fixtures
Armstrong Model Z358 Thermostatic Mixing Valves
Armstrong Model Z358 Thermostatic Mixing Valves are suitable for
installation at or near a point of use for direct tepid water supply to an
emergency fixture or grouping of fixtures.
The Z358 series has been designed specifically to provide tepid water to
emergency fixtures as detailed in ANSI Z358.1-2009.
The Z358 Series offers:
• Site Adjustable – Mechanical maximum-temperature
limit stop and single-temperature locking features.
• Thermal shutdown feature is designed to protect user
from unsafe water temperatures or hot water/chemical
reaction should cold supply be interrupted during use.
• Unique constant cold water flow design ensures that
in the event of a hot supply failure the Z358 Series will
allow cold water to flow to fixture.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
9
Conformité Européane (CE)
Fan Blower
CE Marked
Fan
Blower
CE Marked
Fan
Motor
Fan Motor
CE Marked
CE Marked
Water Pressure
Switch
Water
Pressure
Switch
CE Marked
CE
Marked
Gas Train
and
Control Panel
Gas
Train
and
by MaxonPanel
Europe
Control
by Maxon Europe
Not Shown:
Not
Shown:
Transfer Pump CE Marked
••• Transfer
Pump CE Marked
Flame Ignitor CE Marked
•• Flame
IgnitorCE
CE
Marked
Flame Detection
Marked
• Flame Detection CE Marked
Water Valve
CE Marked
Water
Valve
CE Marked
Flo-Direct Complete Thermal Exchange
Gas Fired Water Heaters are fully
compliant and correctly identified as
required by the relevant CE marking
regulations.
Level Switches
Level
Switches
CE Marked
CE
Marked
This includes:
• Low Voltage Directive (2006/95/EC)
• EMC Directive (2004/108/EC)
• Machinery Directive (98/37/EC)
• Gas Directive (90/396/EC)
Flo-Direct
U.S.Patent
Patent
5,924,301
Flo-Direct isisU.S.
5,924,391
High Heat Value vs. Low Heat Value
High Heat Value = Total Energy Content of Fuel
Low Heat Value = Total Heat of Hot Water
or Steam Generated by the boiler
High Heat Value (HHV) is the method for evaluating boiler efficiency typically used in the USA. The efficiency is calculated by comparing
the total heat content (enthalpy) of the hot water or steam generated by a boiler with the total potential energy of the input fuel.
As a result efficiency measured using HHV will not exceed 100%.
Low Heat Value (LHV) is the method for evaluating boiler efficiency typically used in Europe. A LHV calculation includes recoverable
heat.
Combustion exhaust contains hot water vapor which is created by both the evaporation of the water contained in the input fuel and the
chemical reaction in the combustion process. Newer technologies such as “condensing” type water heaters and boilers can capture the
“latent” heat.
As a result efficiency measured using LHV can, in some cases, exceed 100%.
When developing unit and system efficiency comparisons it is important to first determine whether the stated heat transfer efficiency is
measured in HHV or LHV.
10
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Hose Stations
Steamix® - Will Not Pass Live Steam
Rugged steam valve seat is made from
new high-temperature-resistant polymer.
Whisper quite operation is
achieved by special steam diffuser
design.
Cut-away image of:
Will not pass live steam
if cold water pressure falls or
fails completely.
Fails safe.
Steamix will deliver only cold
water if the primary operating
component (diaphragm) is
damaged.
Intrinsically safe.
Reliable all stainless steel
internal parts move freely
every time flow takes place.
Operating principle means
steam can flow only if
water is already flowing.
Flexibility of application allows
User friendly single-handle
temperature control means
no “juggling” of inlet supply
globe valves is required to find
temperature.
2-year warranty on mixing unit
wetted components.
12
Steamix to operate at lower steam
pressures than other style dual
globe valve Mixing “Y”.
Lock in the temperature.
Tamper resistant locking device
option allows Steamix to be preset
to a desired temperature and
locked. Discourages adjustments
by unauthorized personnel.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Steamix® - Steam & Water Hose Stations – Standard
Steamix - Standard
The Steamix – Standard series is supplied
fully assembled and pressure tested in the
following configurations.
Steamix Model 2030 - is a steam/water mixing
valve of brass/stainless steel construction.
Steamix Model 2031 - is a steam/water mixing
valve of brass/stainless steel construction.
The valve is supplied as standard with 3/4”
inlet union connections with integral strainers,
an outlet ball valve for flow control and an
outlet dial thermometer.
Steamix Model 2032 - is a steam/water mixing
valve of brass/stainless steel construction.
The valve is supplied as standard with 3/4”
inlet union connections with integral strainers,
an outlet ball valve for flow control and an
outlet dial thermometer. The unit is supplied
installed on a stainless steel hose rack.
Steamix Model 2033 (shown) - is supplied as
above and also includes 25 feet of “safety
yellow” washdown hose, a rubber cushioned
spray nozzle with, swivel adapter and a
stainless steel nozzle hook.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
13
Steamix® - Steam & Water Hose Stations – Premium
Steamix - Premium
The Steamix – Premium series is supplied fully
assembled and pressure tested in the following
configurations.
Steamix Model 2031P - is a steam/water mixing
valve of brass/stainless steel construction. The
valve is supplied as standard with integral inlet
supply risers comprising 3/4" Y-type strainers
and 3/4" ball valves cross-linked by a stainless
steel bridge piece and lever for simultaneous
on/off control of both inlet supplies. The unit
is supplied with stainless steel dual scale top
mount Thermometer and Inlet Check Valves.
Steamix Model 2032P - is a steam/water mixing
valve of brass/stainless steel construction. The
valve is supplied as standard with integral inlet
supply risers comprising 3/4" Y-type strainers
and 3/4" ball valves cross-linked by a stainless
steel bridge piece and lever for simultaneous
on/off control of both inlet supplies. The
unit is supplied with a stainless steel hose
rack. Stainless Steel dual scale top mount
Thermometer and Inlet Check Valves.
Steamix Model 2033P (shown) - is a steam/
water mixing valve of brass/stainless steel
construction. The valve is supplied as standard
with integral inlet supply risers comprising 3/4"
Y-type strainers and 3/4" ball valves cross-linked
by a stainless steel bridge piece and lever for
simultaneous on/off control of both inlet supplies.
The unit is supplied with a stainless steel hose
rack. Stainless Steel dual scale top mount
Thermometer and Inlet Check Valves.
Steamix Model 2033P also includes 25 feet of
“safety yellow” washdown hose rated, low-heattransfer polymer spray nozzle with trigger guard,
swivel adapter and a stainless steel nozzle hook.
14
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Steamix® - Steam & Water Hose Stations – Stainless Steel
Steamix - Stainless Steel
The Steamix – Stainless Steel series is
supplied fully assembled and pressure tested
in the following configurations.
Steamix Model 2030SS - is a steam/water mixing
valve of Type 304 stainless steel construction.
Steamix Model 2031SS - is a steam/water mixing
valve of Type 304 stainless steel construction.
The valve is supplied as standard with all
stainless steel (SS) integral inlet supply risers
comprising 3/4” Y-type strainers and 3/4” ball
valves cross-linked by a stainless steel bridge
piece and lever for simultaneous on/off control
of both inlet supplies. Stainless Steel dual
scale top mount Thermometer and Stainless
Steel Inlet Check Valves.
Steamix Model 2032SS - is a steam/water mixing
valve of Type 304 stainless steel construction.
The valve is supplied as standard with all
stainless steel (SS) integral inlet supply risers
comprising 3/4” Y-type strainers and 3/4” ball
valves cross-linked by a stainless steel bridge
piece and lever for simultaneous on/off control
of both inlet supplies. The unit is supplied
with a stainless steel hose rack. Stainless
Steel dual scale top mount Thermometer and
Stainless Steel Inlet Check Valves.
Steamix Model 2033SS (shown) - is a steam/
water mixing valve of Type 304 stainless steel
construction. The valve is supplied as standard
with all stainless steel (SS) integral inlet supply
risers comprising 3/4” Y-type strainers and
3/4” ball valves cross-linked by a stainless
steel bridge piece and lever for simultaneous
on/off control of both inlet supplies. The
unit is supplied with a stainless steel hose
rack. Stainless Steel dual scale top mount
Thermometer and Stainless Steel inlet Check
Valves.
The STEAMIX Model 2033SS also includes
25 feet of “safety yellow” washdown hose, SS
rubber cushioned spray nozzle with SS swivel
adapter and a stainless steel nozzle hook.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
15
Armstrong - Hot & Cold Water Hose Stations
Armstrong - Hot & Cold Water Hose Stations
Armstrong Hot and Cold water hose stations replace
the basic Mixing Y with a Rada® 320 thermostatic
mixing valve as the primary water temperature
controller.
With the Rada 320 you can:
• Change outlet water temperature from full cold to the
field-adjustable maximum limit stop in a single handle
turn
• Set and lock to a single temperature and maintain
outlet temperatures +/-2oF (1oC) in the event of inlet
pressure and/or temperature fluctuation or change
• Protect the operator with a thermal-shutdown feature
if the cold water inlet supply fails
IMPORTANT NOTE: Thermostatic products used by
our competitors for this application cannot provide a
temperature range from full cold to the field-adjustable
maximum limit stop. Nor can they access temperatures
within 5oF (2oC) of either inlet supply temperature.
Model 3031 – Standard
Rada 320 Thermostatic Mixing Valve with integral
risers for simultaneous on/off control of both inlet
supplies. The unit is supplied fully assembled and
pressure tested installed on a stainless steel wall
mounting plate.
Model 3032 – Standard
Rada 320 Thermostatic Mixing Valve with integral
risers for simultaneous on/off control of both inlet
supplies. The unit is supplied fully assembled and
pressure tested installed on a stainless steel hose rack.
Model 3033 – Standard
Rada 320 Thermostatic Mixing Valve with integral
risers for simultaneous on/off control of both inlet
supplies. The unit is supplied fully assembled and
pressure tested installed on a stainless steel hose rack.
Model 3033 is supplied with 25’ Armstrong “safety
yellow” washdown hose, SS rubber cushioned spray
nozzle with swivel adaptor and stainless steel nozzle
hook.
Armstrong – Hot & Cold Water Hose Stations - Premium
The Armstrong Hot & Cold Hose Stations – Premium
series are supplied as above with inlet check valves
and a corrosion resistant industrial nickel plating on all
components excepting Rada 320 (heavy duty industrial
chrome).
Models Available:
3031S, 3032S & 3033S
16
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
Armstrong - Single Temperature Hose Stations
Armstrong Single Temperature Hose
Stations
Armstrong Single Temperature Hose Stations
are supplied in type 316 Stainless Steel and are
ideal for heavy duty wash down in systems which
do not require temperature adjustment at the
point of use.
Model 1032 - 316 Stainless Steel full port 3/4”
NPT) ball valve affixed to a 316 Heavy-duty
stainless steel hose rack with mounting plate,
stainless steel hose strain relief and stainless
tee outlet thermometer. The unit is supplied fully
assembled and pressure tested.
Model 1033 - As above with 25’ Armstrong “safety
yellow” washdown hose, SS rubber cushioned
spray nozzle with swivel adaptor and stainless
steel nozzle hook. The unit is supplied fully
assembled and pressure tested.
Armstrong Hot Water Group, 221 Armstrong Blvd., Three Rivers, MI 49093 – USA Phone: 269-279-3602 Fax: 269-279-3130
armstronginternational.com
17
Notes
Armstrong provides intelligent system solutions that improve utility performance, lower energy consumption,
and reduce environmental emissions while providing an “enjoyable experience.”
Armstrong Hot Water Group
221 Armstrong Blvd., Three Rivers, MI 49093 - USA Phone: 269-279-3602, Fax: 269-279-3130
armstronginternational.com
Bulletin HW-410
Printed in U.S.A. - 6/10
© 2010 Armstrong International, Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement