R7D-MS4
INSTRUCTION MANUAL
POTENTIOMETER INPUT MODULE, 4 points MODEL
(DeviceNet)
R7D-MS4
BEFORE USE ....
POINTS OF CAUTION
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ CONFORMITY WITH EC DIRECTIVES
•The equipment must be mounted inside the instrument
panel of a metal enclosure.
•The actual installation environments such as panel configurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ PACKAGE INCLUDES:
Potentiometer input module......................................... (1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
■ GENERAL PRECAUTIONS
Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
•Indoor use
•When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
•Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet.
EM-7802-Q Rev.1
P. / 7
R7D-MS4
COMPONENT IDENTIFICATION
(B)
23
■ EXTENSION MODULE
Combinations with the R7D-EA8, R7D-EA16, R7D-EC8A,
R7D-EC16A, R7D-EC8B or the R7D-EC16B are selectable.
(E)
901
901
NODE ADD.
456
78
78
456
78
23
(D)
1 2 3 4 5 6 7 8
X1
456
23
X10
NS
MS
(C)
901
(A)
CNFG.
B.RATE
10 11 12 13 14 15 16 17 18
1 2 3 4 5
1
2
(F)
(A)
(B)
(C)
(D)
(E)
(F)
(G)
3
4
5
6
7
8
9
(G)
Status Indicator LED
Node Address Setting Rotary SW
Baud Rate Setting Rotary SW
Operating Mode Setting DIP SW (SW1)
PC Configurator Jack
DeviceNet, Power Supply Terminals
Input Terminals
■ STATUS INDICATOR LED
LED
STATE
TO INDICATE
MS
Green
Operating in a normal condition
Flashing Green Standby (needs commissioning)
Red
Critical failure
Flashing Red Minor failure
OFF
No power supplied
NS
Green
Link on-line and connections in
the established state
Flashing Green Link on-line but no connections in
the established state
Red
Critical link failure
Flashing Red Minor link failure
OFF
No power supplied
■ NODE ADDRESS
Node Address is selected between 1 and 63 in decimal. The
left switch determines the tenth place digit, while the right
switch does the ones place digit of the address.
23
901
23
456
78
78
456
901
Node Address Setting (x10)
■ BAUD RATE
Baud Rate is selected with the rotary switch.
78
23
• Conversion rate / Accuracy (SW1-3, 1-4)
SW1-3 SW1-4 Conversion rate / Accuracy
OFF
OFF
80 msec. / ±0.1% (*)
ON
OFF
40 msec. / ±0.2%
OFF
ON
20 msec. / ±0.4%
ON
ON 10 msec. / ±0.8%
(*) Factory setting
Caution ! - SW1-5, 1-6, 1-7, 1-8 are unused. Be sure to turn
off unused ones.
■ DeviceNet TERMINAL ASSIGNMENT
1
NO.
1
2
3
4
5
0 : 125 kbps (factory setting)
1 : 250 kpbs
2 : 500 kbps
3 thr. 9 : Auto-tracking
901
Baud Rate Setting
2
ID
V+
CAN_H
Drain
CAN_L
V–
3
4
5
FUNCTION, NOTES
Network power supply +
Network data High
Shield
Network data Low
Network power supply –
■ INPUT TERMINAL ASSIGNMENT
10
11
12
13
14
15
16
17
18
H0
S0
H1
S1
NC
H2
S2
H3
S3
1
2
3
4
5
6
7
8
9
NC
L0
NC
L1
NC
NC
L2
NC
L3
Factory setting : 00
Node Address Setting (x1)
456
■ OPERATING MODE
• Extension (SW1-1, 1-2)
SW1-1 SW1-2 Extension
OFF
OFF No extension (*)
ON
OFF Discrete input, 16 points
OFF
ON Discrete output, 16 points
NO.
1
2
3
4
5
6
7
8
9
ID
NC
L0
NC
L1
NC
NC
L2
NC
L3
FUNCTION
No connection
Pot L0
No connection
Pot L1
No connection
No connection
Pot L2
No connection
Pot L3
NO.
10
11
12
13
14
15
16
17
18
ID
H0
S0
H1
S1
NC
H2
S2
H3
S3
FUNCTION
Pot H0
Pot S0
Pot H1
Pot S1
No connection
Pot H2
Pot S2
Pot H3
Pot S3
The R7D communicates in the baud rate setting detected at
the startup with the switch set to the positions 0 (125 kbps),
1 (250 kbps) or 2 (500 kbps).
For the settings 3 through 9, it analyzes the PLC’ s network
to determine the baud rate on the network.
EM-7802-Q Rev.1
P. / 7
R7D-MS4
CONNECTION DIAGRAM
WIRING INSTRUCTIONS
Connect the unit as in the diagram below.
■ SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solderless terminals with insulation sleeve do not fit. Applicable
wire size: 0.3 – 0.75 mm2
INPUT 0
H0 10
V+
CAN_H
Drain
CAN_L
V–
S0 11
L0 2
4 min.
(.16)
3.2 (.13) dia.
6 max.
(.24)
INPUT 1
H1 12
3 (.12) max.
S1 13
L1 4
12 (.47) max.
INPUT 2
H2 15
S2 16
L2 7
INPUT 3
H3 17
S3 18
L3 9
■ Input Connection Example
POTENTIOMETER
max.
+
3
Hn
2
Sn
min.
1
–
Ln
EXTERNAL DIMENSIONS
unit: mm (inch)
115 (4.53)
54 (2.13)
18.5 (.73)
17 (.66)
10 11 12 13 14 15 16 17 18
1
2
3
4
TERMINAL BLOCK for
DeviceNet, POWER
5
6
7
8
9
6 (.24)
5.5 (.22)
3 (.12)
1 2 3 4 5
3 (.12)
50 (1.97)
DIN RAIL
35mm wide
30 (1.18)
[5 (.20)]
18–M3 SCREW
TERMINALS
for INPUT
EM-7802-Q Rev.1
P. / 7
R7D-MS4
CONFORMITY WITH CE MARKING
■ CE MARKING
CE marking requires to integrate safety regulations existed in each country in EU territory and to secure smooth distribution
of products of which safety is guaranteed. It is mandatory by law that products distributed and sold in EU territory to have
CE mark which shows that the product conforms with the requirements of EC Directive. Each EC Directive describes the
scope of apparatuses to which that EC Directive is applied. M-System’s R7D must conform with EMC Directive.
Each Directive states only basic requirements. In order to mark the CE on an assembled machinery equipment, its manufacturer needs to check the overall conformity with Directives applicable to it.
■ WARNINGS AND CAUTIONS WHEN INSTALLING THE R7D
The R7D needs to be installed in a control panel. This is effective not only to ensure general safety but also to contain noise
emissions by the R7D inside the control panel. We conduct a series of testing to see that the product conforms to EMC Directive while it is installed in the control panel.
Warning and cautions when installing R7D are stated below.
•Use control panels with an internal panel plate, both made of metal, when installing the R7D.
•Make sure to adequately ground the control panel and the internal panel plate with a thick cable to maintain low impedance
at high frequency.
•Use shielded cables for the signals taken out of the control panel.
•When painting the internal plate of the control panel, apply masking to expose metal surface to secure conductivity at the
sections where the following parts are attached:
- Bolts attaching the internal panel to the control panel
- Earth clamp on the shielded cable
•Noise emissions inside the control panel might leak through its openings. Design them as small as possible. Recommended
diameter is 10 cm or less.
Supplement:
Additional measures may be taken depending upon actual installation sites. These points of cautions are illustrated in the
next page.
•Prevent noise leakage by wrapping cables using shield covers, shield tubes and flexible conduits etc. if noise leaks through
the cable outlet.
•Use an electromagnetic shield gasket and block up the gap between the control panel cabinet and its cover, if noise leaks
through it.
•Connecting the internal panel plate and the cover of the control panel to the main cabinet using an earth strap may be effective to strengthen the grounding.
•Electromagnetically shielded control panel cabinet is effective for shielding.
EM-7802-Q Rev.1
P. / 7
R7D-MS4
• Points of cautions applicable when installing the R7D Series
Install the R7D Series inside
a control panel.
Attachment part of earth
clamp should be fixed with
screw in conduction with the
internal panel plate.
Keep the opening for
ventilation as small as
posible.
Attach an electromagnetically shielded
filter when noise leaks
through the opening.
Keep the opening
for cabling as small as
possible.
To external apparatus
Use (e.g.) a shield cover
when noise leaks through
the opening.
By connecting the
internal panel plate
and the panel cover with
an earth strap, grounding
may be strengthened and
EMC may be improved.
Install an electromagnetically
shielded gasket when
noise leaks through
Shielding is strengthened
the opening.
by using an electromagnetically shielded
control panel.
Ground the control panel
at low impedance using
(e.g.) braided wires.
EM-7802-Q Rev.1
P. / 7
R7D-MS4
■ WARNINGS AND CAUTIONS WHEN LAYING CABLES
Signal cables connected to the R7D contain high-frequency components. Since these cables has the same effect as an antenna, they emit these high-frequency components to the external space as noise or overlaps noise from the external space
on themselves.
Cables with shielding should be used for the signal line due to the above reason.
EMC conformance test is conducted in the condition that shielded cables and earth clamps are used with the R7D.
Warning and cautions when laying cables are stated below. These points of cautions are illustrated in the next page.
•Use shielded cables for those signal cables installed out of the control panel and for thermocouple and RTD extension
wires.
•All the network cables connected to R7D should be shielded.
•Use exclusively designed network cables for the DeviceNet.
•Expose the shield at a part of the cable cover, clip it with an earth clamp, and ground it to the internal panel of the control
panel. A drain wire connected to the panel in a pig-tail form cannot maintain low impedance against high-frequency noise,
thus grounding (noise shielding) in this form will not be effective.
Supplement:
Additional measures may be taken depending upon actual installation sites. These points of cautions are illustrated in the
next page.
•Keep cables as short as possible. It prevents noise emissions from the cables and noise overlapping to the cables.
•Attach a ferrite core to reduce noise impact to the signal cables susceptible to the noise. Ferrite core can be attached close
to the cable outlet of the control panel or close to the I/O terminal or connector, whichever is more effective. Also, the impact
might be reduced by winding the cable around the ferrite core for extra turns or attaching multiple ferrite cores.
•Keep cables which are easily affected by noise away from those which can be a noise source.
Motor Drive
Cable
Power Supply
Cable
Often being a noise source
DC Signal Cable
Network Cable
Analog Signal
Cable
Often subject to noise interference.
In the following are examples of effective ways to lay cables separately:
•Keeping physical distance (farther than 20 cm from motor drive cables, farther than 10 cm for other groups).
•Dividing off by a grounded metal plate
•Grouping into separate grounded metal pipes or cable shields.
Wires on each side of a filter should not be too close to each other. Noise could ride onto the other side of cable.
Extra attention needs to be paid at the following parts.
•Noise filter that is enclosed in power cables.
•Ferrite core that is attached to signal cables.
•Noise limiting circuit (surge quenching circuit, transient absorber circuit, etc.) that is enclosed in signal cables.
EM-7802-Q Rev.1
P. / 7
R7D-MS4
• Points of cautions applicable when wiring the R7D Series
Keep the wires away from
each other at both ends of
the filter.
Noise
Filter
To external apparatus
Keep the cable as
short as possible.
Earth
Clamp
Shielded
Cable
Remove a part of the shielded
cable cover and ground it
to the internal panel
plate using an earth
clamp.
To external apparatus
Motor
Drive Cable
Maintain distance between
cables and noise sources.
Grounding in pig tail form
is not effective.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]
EM-7802-Q Rev.1
P. / 7
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement