Modular I/O Systems
INSIDE the Enclosure
BL67
I/O Stations
OUTSIDE the Enclosure
AIM
FDN20
• -40° to 70°C
• Rugged 50G shock/vibration
• Fully encapsulated
• Highest density,
smallest footprint
• Drive interface
• OEM applications
BL20
• Connectorized
• Free configuration software
• Integrated valve interface
• Integrated motor starters
• Free configuration software
• AC I/O
piconet ®
• Miniature size
• Connectorized
• High-speed fiber-optic subnet
The best I/O available.
No matter what I/O you need, we’ve
got you covered. TURCK has a complete
line of I/O products designed to save
you time and money. With five product
families and thousands of part numbers,
TURCK has exactly the right product for
your applications. Many I/O products
are custom designed for specific
applications, including interfacing directly
with motors, drives, valves, operator
panels, push buttons and analog and
digital sensors. With TURCK you don’t
have to be locked into proprietary
PLC I/O solutions. From your PLC
to every point in your automation
application, TURCK works! Visit our
website today to order a Network I/O
catalog containing over 590 pages of
innovative products.
Call us with your next application:
1-800-544-7769
email: [email protected]
www.turck.com
©2007 TURCK, Inc.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
TURCK – Your First Choice In
Industrial Automation
TURCK is one of the leading manufacturers in the industrial automation sector. All our activities are focused on improving our
customer's manufacturing processes. Our strategy is simple yet challenging: We want to provide our customers with simply the
best – quickly, flexibly and reliably.
Maintaining close cooperation with our customers is a key factor to success. We constantly strive to provide expert application
engineering and customer service support to ensure the continued productivity and cost-efficiency of industrial installations
worldwide.
With production sites in Germany, Switzerland, the USA and China, TURCK is capable of swiftly adapting to the specific needs
of customers throughout the world.
We believe in innovation as a constant process through the continuous development of new products and solutions for the
future benefit of our customers and partners.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
2
TURCK
RFID Products
BL ident – Modular RFID Systems
SPS
PLC
program
Bus
• BL ident interface,
2, 4, 6 or 8-channel in
(IP 20) BL20 platform
• Address switch/
service interface
BL ident Cordsets
Molded (M12) eurofast® BL ident cables
are available for reliable communication
along the transmission path between the
interface module and read/write head. This
makes connection of the read/write heads
simple and fail-safe.
BL ident Data Carriers
The data carriers are available in diameters
of 16, 20, 30 and 50 mm. The R20, R30
and R50 units are available with
EEPROM or FRAM memory. Generally, the
FRAM data carriers may be processed
by a power of ten times faster than
the EEPROM data carriers, and
withstand 1010 write operations
(in comparison to EEPROMs
approx. 105 operations).
3
• LEDs for
status
display
• Cage clamp or screw
terminal
connection for
read/write heads
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
• Plug connection for fieldbus
and power supply
• Address switch/
service interface
• BL ident interface,
2, 4, 6 or 8-channel in (IP 67)
BL67 platform
• LEDs for status display
• M12 plug connector or
read/write heads
BL ident
cordsets
Read/write head
RFID-Data carrier (TAG)
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
4
TURCK
RFID Products
BL ident RFID From TURCK
Higher Application Speed Leads to Production Effeciency
• Data carriers with minimal read/write time of 0.5 ms per byte
Modular Design Provides Flexible Integration into
Existing Systems
• 2, 4, 6 or 8-channel interfaces
• Various shapes of read/write heads to meet specific
application requirements: cylindrical M18 and M30, square
CK40 and Q80, as well as ring-shaped S32XL
• Read-write heads with air interfaces (read-write intervals)
between 15 and 145 mm
• Tested standard function blocks for varying types of controls
for complex functions and troubleshooting
Typically, a plant's efficiency is highly dependent on the
maximum possible speed of the transport equipment. While
many conventional RFID systems allow only static read and write
operations, the new BL ident system from TURCK is capable of
reading and writing at all times. Data can be exchanged even
when the data carrier is in motion. With a read-write time of
0.5 ms per byte, BL ident is one of the fastest inductive RFID
systems on the market. Even transport speeds of over 10 ms are
achievable.
Expanded Temperature Range
• Data carriers for temperatures up to 210°C (410°F)
State-of-the-Art Storage Technology
• Long-life FRAM data carriers for virtually an unlimited number
of write operations
Simple Integration into Control Environment
• Standard functions blocks and interfaces for PROFIBUS ®-DP,
DeviceNet™, Modbus-TCP, PROFINET, and EtherNet/IP™
• By using programmable gateways in RFID systems to alleviate
processor and network loads it will significantly optimize
your network. Programmable gateways are programmed with
CoDeSys software available free of charge from our website.
CoDeSys is a IEC 61131-3 standard which includes ladder
logic programming.
5
BL ident is available with 2, 4, 6 or 8-channels. BL ident systems
may be integrated into existing systems, including PROFIBUS-DP,
DeviceNet, Modbus-TCP, PROFINET, and EtherNet/IP. All while
providing IP 20 or IP 67 protection.
BL ident data carriers are available with a temperature resistance
of up to 210°C (410°F), for 30 minutes in addition to standard
data carriers for temperatures up to 120°C (248°F).
Use of state-of-the-art FRAM storage technology allows 1010
write operations and an unlimited number of read operations
on TURCK data carriers. This makes replacing data carriers
practically unnecessary; even when used in applications requiring
repeated write operations. This dramatically increases the
availability of the equipment. And all data remains stored on the
data carriers for 10 years (at appropriate ambient temperatures).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Modular And Simple To Integration
BL ident Interfaces
BL ident modularity provides customization
in both IP 20 rated cabinet installation and
IP 67 rated field installations.
Depending on the system requirements,
up to 8-channels can be added in a single
node. All channels operate in parallel so that
there is no time delay during communication
between the data carrier and module.
Additional functions, such as intentional
switch-off of individual heads, are integrated
when they are installed close to one another.
A large memory of 32 kBytes allows
asynchronous processing of the individual
commands. Standard function modules and
or sample code are available for integration
into the control and fieldbus environment.
Contact factory for assistance.
LEDs display diagnostics for the individual
RFID channels and fieldbus-specific
diagnostic messages.
Additional standard input/output
modules may also reside in the same rack
configuration.
BL ident Interface Modules Adapt to the Application
2, 4, 6 or 8-channel versions
Field installation provides IP 67 protection
Switch cabinet installation provides IP 20 protection
Channels operate in parallel so that there are no delays – even in multiple
channel setups – for interruption-free production
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
6
TURCK
RFID Products
Roughed And Temperature Resistant
Until now, using RFID in extreme
temperature applications has been nearly
impossible, incredibly expensive and
highly unreliable.
TURCK has successfully solved the
challenges of these installations by
developing data carriers (TAGs) resistant
to temperatures up to 210°C (410°F)
for 30 min. With the ability to read
and write data immediately after high
temperature exposure, plant productivity
and efficiency greatly increases.
BL ident data carriers guarantee
data retention for up to 10 years at
appropriate ambient temperatures.
The space saving shapes of these high-temperature data carriers (110 x 95 x 70 mm as
well as cylindrical (diameter 22 mm, length 135 mm)) allow use in applications with
limited space.
7
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Fast And Durable
BL ident data carriers (TAG‘s) operate at a
frequency of 13.56 MHz, and are therefore
significantly faster than conventional 125 kHz
systems.
Data carriers with EEPROM or FRAM memories
are available. TAG‘s with FRAM memories allow
significantly higher data transfer rates for reading
and writing at conveying speeds of higher than
10 ms.
In addition to the higher speed, FRAM memories
can also withstand significantly more write
operations than EEPROMs.
While the maximum limit for EEPROMs is usually
reached after 100,000 cycles, FRAMs allow up to
1 Billion write operations. Even at 100,000 write
operations per day, this equates to a service life of
27 years.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
8
TURCK
RFID Products
Using RFID poses a lot of questions, such as:
• How fast can the products run past the
read/write heads?
• How close do the products have to be
when they run past the read/write heads?
Most users are uncertain of what RFID
can do. General information, such as
recommended read/write interval or transfer
rate, are usually insufficient for evaluating the
equipment for a specific application, because
of variables such as data quantity, speed and
distance result from a complex interaction
between the read/write heads and data
carriers.
TURCK's BL ident configurator can simulate
an application and aid in equipment
selection. Application parameters and values
can be found quickly and easily by using the
configurator.
When two or more read/write heads are
installed directly next to one another, they
can be switched on and off alternately. This
prevents any mutual interference.
9
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
The free online configurator, available at
www.turck.com, uses the entire TURCK
product database to supply up-to-date data.
In addition to simulating the application, the
configurator also generates the corresponding
data sheets and documents.
Standard function blocks are available for
system integration into the various bus and
control environments, like PROFIBUS®-DP,
Ethernet and DeviceNet™. This simplifies the
complex programs for the various read/write
commands and allocation of the channels.
Even limited installation space no longer present any
problems for implementation of your application.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
10
TURCK
RFID Products
Explanation of RFID Read Zone Dimensions
Max Zone Width (at recommended read/write range
Maximum
Read/Write
Range
Minimum Zone Width
Recommended
Read/Write
Range
Minimum
Read/Write
Range
Use this drawing as a reference when researching tag/transceiver combinations for your application.
11
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
BL ident – New advantages with RFID from TURCK
.............................. 5
Part Number Keys .......................................................... 13 - 14
Modular RFID Systems from TURCK
......................................... 3 - 4
Read/Write Heads ............................................................... 15
Data Carriers .................................................................... 16
Interfaces
.................................................................. 17 - 18
Cordsets ......................................................................... 20
Handheld
.................................................................. 21 - 22
Configurator
..................................................................... 9
Accessories ................................................................. 23 - 26
Technical Data
BL ident Data Carriers
.......................................................... 27
BL ident Read/Write Heads
..................................................... 45
BL ident Interfaces and Extension Modules ..................................... 59
Index ............................................................................ 93
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
12
TURCK
RFID Products
BL ident – Type Code
Interfaces
B L 6 7 – GW – D P V 1
GW
PG
Gateway
Programmable
DPV1: PROFIBUS DPV1
DN:
DeviceNet™
EN:
Ethernet/Modbus-TCP
EN-PN: Ethernet/PROFINET
EN-IP: Ethernet/IP
BL67:
Housing BL67,
Degree of protection IP 67
BL20:
Housing BL20,
Degree of protection IP 20
Read-Write Heads (Transceiver)
T N – C K 4 0 – H 1 1 4 7
Housing style:
B flush
a
N non flush
b
TURCK
Internal code:
7
Special assignment
Number of contacts
4
Mechanical version:
1
straight
Connector housing:
Housing:
H1 eurofast ® connector (M12 x 1)
M18
Threaded barrel
M30
Threaded barrel
CK40 Rectangular, 40 x 40 mm
Q80
Rectangular, 40 mm high
S32XL Ring type, 32 mm high
13
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Data Carrier (TAG)
T W
– R 2 0
– H T – K 2
Memory size:
K2
2 kByte
B64 64 Byte
B128 128 Byte
R read only
W read/write
TURCK
HT
High temperature
Dimensions:
R16: Ø 16
R20: Ø 20
R22: Ø 22
R30: Ø 30
R50: Ø 50
BL ident Interfaces
BL ident's modular design provides users with a custom-tailored solution for IP 20 rated cabinet installation and IP 67 rated field installation.
Depending on the application requirements, up to 8-channel interface modules can be set up (in two steps) or supplemented retroactively.
All channels operate in parallel so that there is no time delay during communication between the data carrier and module. Additional
functions, such as intentional switch-off of the individual heads, are integrated when they are installed in proximity to one another.
BL ident's large memory of 32 kBytes allows asynchronous processing of the individual commands. Standard function blocks and or sample
code are available for integration into the control and fieldbus environment. Contact factory for assistance.
Fieldbus diagnostics for supply of the individual RFID channels is accomplished using LEDs, supplemented by fieldbus-specific diagnostic
messages. Additional standard input/output modules may also reside in the same rack configuration.
BL ident Read/Write Heads
Data carriers combined with different types of read/write heads can achieve ranges from 15 to 145 mm. Each read/write head is also
capable of processing the various types of data carriers in the TURCK line, regardless of whether it is an EEPROM or FRAM storage device
– only one read/write head is required.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
14
TURCK
RFID Products
BL ident – Read/Write Heads
Housing
Part Number
ID Number
Installation Conditions
Output Functions
Connection
18 mm Embeddable
TB-M18-H1147
M7030001
Flush
Read/write
Only with BL ident
cordsets
18 mm Nonembeddable
TN-M18-H1147
M7030002
Non Flush
Read/write
Only with BL ident
cordsets
30 mm Embeddable
TB-M30-H1147
M7030003
Flush
Read/write
Only with BL ident
cordsets
30 mm Nonembeddable
TN-M30-H1147
M7030004
Non Flush
Read/write
Only with BL ident
cordsets
40 mm Nonembeddable
TN-CK40-H1147
M7030006
Partial Embedding
Read/write
Only with BL ident
cordsets
80 mm Nonembeddable
TN-Q80-H1147
M7030007
Non Flush
Read/write
Only with BL ident
cordsets
32 mm Nonembeddable
TN-S32XL-H1147
M7030008
Non Flush
Read/write
Only with BL ident
cordsets
See page 91 - 92 for dimensional drawings.
15
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
BL ident – Data Carriers
Housing
1
2
3
Part Number
ID Number
Memory
Size
Memory
Organization
Operating
Temperature
TW-R16-B128
M6900501
128 Byte
EEPROM
-25 to +85°C
(-13 to +185°F)
Read/write
1
TW-R20-B128
M6900502
128 Byte
EEPROM
-25 to +85°C
(-13 to +185°F)
Read/write
2
TW-R30-B128
M6900503
128 Byte
EEPROM
-25 to +85°C
(-13 to +185°F)
Read/write
3
TW-R50-B128
M6900504
128 Byte
EEPROM
-25 to +85°C
(-13 to +185°F)
Read/write
4
TW-R20-K2
M6900505
2 kByte
FRAM
-20 to +85°C
(-4 to +185°F)
Read/write
2
TW-R30-K2
M6900506
2 kByte
FRAM
-20 to +85°C
(-4 to +185°F)
Read/write
3
TW-R50-K2
M6900507
2 kByte
FRAM
-20 to +85°C
(-4 to +185°F)
Read/write
4
TW-R50-90-HT-B128
M1542326
128 Byte
EEPROM
-40 to +210°C
(-40 to +410°F)
Read/write
5
TW-R50-90-HT-K2
M1542329
2 kByte
FRAM
-40 to +210°C
(-40 to +410°F)
Read/write
5
Function
Reference
4
5
Extreme Temperatures
What can you do when the temperatures are
below -20°C or above 70°C?
BL ident data carriers from TURCK are
designed for extreme temperatures. A specially
developed jacket protects the data carriers
against extreme temperatures, from -40 to 210°C
(-40 to 410°F) for 30 min.
TURCK data carriers can even be used in
applications such as painting lines in the
automotive industry, which prohibited use of
RFID products until now.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
16
TURCK
RFID Products
BL ident – Supported IP 20 Devices
Housing
Part Number
ID Number
Bus
BL20-GW-DPV1
BL20-GWBR-DN
BL20-GW-EN-IP
BL20-PG-EN
BL20-PG-EN-IP
M6827234
M6827168
M6827247
M6827249
M6827248
PROFIBUS - DPV1
DeviceNet™
Ethernet/IP
Modbus/TCP - Programmable
Ethernet/IP - Programmable
BL20-2RFID-A
M6827233
Two channel RFID extension module,
acyclical exchange of data, used for
most standard installations
BL20-2RFID-C
M6827239
Two channel RFID extension module,
cyclical exchange of data. Designed
specifically for Profibus PLC's that only
support DPV0
BL20-S4T-SBBS
M6827046
Base module
Some applications
require read/write heads
be located very close to one another
where it is virtually impossible to prevent
mutual interference.
In such cases, the channels can be switched
on and off so that the channel with a TAG in
its interface (transmission window) is active.
17
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
BL ident – Supported IP 67 Devices
Housing
Part Number
ID Number
Bus
BL67-GW-DPV1
BL67-GW-DN
BL67-GW-EN-IP
BL67-GW-EN-PN
BL67-PG-EN
BL67-PG-EN-IP
BL67-PG-DP
M6827232
M6827183
M6827229
M6827228
M6827241
M6827246
M6827240
PROFIBUS®-DPV1
DeviceNet™
Ethernet/IP™
PROFINET
Modbus/TCP - Programmable
Ethernet/IP - Programmable
PROFIBUS - DPV1
BL67-2RFID-A
M6827225
Two channel RFID extension
module, acyclical exchange
of data, used for most
standard installations
BL67-2RFID-C
M6827238
Two channel RFID extension
module, cyclical exchange of
data. Designed specifically
for Profibus PLC's that only
support DPV0
BL67-B-2M12
M6827186
Base module
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
18
TURCK
RFID Products
HIGH TEMPERATURE APPLICATIONS
Up until now, it was only possible to integrate data carriers in high temperature applications with expensive hardware and maintenance
costs. Total failure of the data carriers were a daily problem and valuable production lost when waiting to read or write data while the data
carrier cooled to within operating specifications.
TURCK has successfully addressed this application by designing a series of data carriers resistant to temperatures of up to 210°C (410°F).
Additionally, ability to perform immediate read or write functions after running through the high temperature zone increases productivity and
efficiency of your plant.
The space saving shapes of these high temperature data carriers allow adaptation even in applications with limited space.
Application note: Data Carrier TW-R22-HT-B128 must be used with Read-Write Head TNER-Q80-H1147/S1126.
19
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
BL ident – Cordsets
Housing
Part Number
ID Number
Description
RK 4.5T-2-RS 4.5T/S2501
U3-01243
BL ident cordset
Female straight, male straight, 2 m
RK 4.5T-5-RS 4.5T/S2501
U3-01247
BL ident cordset
Female straight, male straight, 5 m
RK 4.5T-10-RS 4.5T/S2501
U3-01241
BL ident cordset
Female straight, male straight, 10 m
WK 4.5T-2-RS 4.5T/S2501
U3-01246
BL ident cordset
Female angled, male straight, 2 m
WK 4.5T-5-RS 4.5T/S2501
U3-01239
BL ident cordset
Female angled, male straight, 5 m
WK 4.5T-10-RS 4.5T/S2501
U3-01237
BL ident cordset
Female angled, male straight, 10 m
RK 4.5T-2/S2051
U3-01240
BL ident cordset
Female straight, 2 m
RK 4.5T-5/S2501
U3-01245
BL ident cordset
Female straight, 5 m
RK 4.5T-10/S2501
U3-01238
BL ident cordset
Female straight, 10 m
WK 4.5T-2/S2051
U3-01244
BL ident cordset
Female angled, 2 m
WK 4.5T-5/S2501
U3-01248
BL ident cordset
Female angled, 5 m
WK 4.5T-10/S2501
U3-01242
BL ident cordset
Female angled, 10 m
CABLE RFID/S2501-30M
RB51347-30M
BL ident bulk cable 30 m
CABLE RFID/S2501-75M
RB51347-75M
BL ident bulk cable 75 m
CABLE RFID/S2501-150M
RB51347-150M
BL ident bulk cable 150 m
CABLE RFID/S2501-225M
RB51347-225M
BL ident bulk cable 225 m
CABLE RFID/S2501-300M
RB51347-300M
BL ident bulk cable 300 m
Note: Custom cable lengths available. 50 meter maximum length.
Prefabricated cordsets are available
for reliable data transfer between
the read/write head and BL ident
interface.
Cable Characteristics:
• Shielded
• PVC outer jacket
• Highly flexible
• Resistant to oil
• High mechanical stability
• UL approved
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
20
TURCK
RFID Products
BL ident – Handheld
TURCK data carriers are easily programmed by
a handheld programming unit for reading and
writing to the data carriers at any location.
The data is displayed on an illuminated
touchscreen (display in decimal, binary,
hexadezimal and ASCII code) where it can
be edited and written to the appropriate data
carrier as required.
The BL ident handheld operates with MS
Windows CE. Data transfer is as simple as
exporting an MS Excel file.
21
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
Description
PD-IDENT-PF
M1542336
Protective foil for display (25 pieces)
PD-IDENT-DS
M1542333
Docking station, incl. power pack, RS232 cable
PD-IDENT-RB
M1542337
Replacement battery
PD-IDENT-BC
M1542335
Battery charger
PD-IDENT-RS
M1542338
Replacement pins (25 pieces)
PD-IDENT-CB
M1542334
Carrying case
PD-IDENT
M1542331
Handheld incl. docking station
PD-IDENT-WLAN
M1542340
Handheld with WLAN feature
Other Features Include:
• Automatic read operation
• Automatic comparison of data records
• Definition of password protected areas
• Optional WLAN, Bluetooth and GPRS features
The WLAN connection allows the BL ident
handheld to transfer data directly to an SPC or
PC – regardless of the location. This means that
the data is always available – even when the
automated system is standing still.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
22
TURCK
RFID Products
BL ident – Accessories
Housing
Part Number
ID Number
BS18
M6947100
Mounting block for
cylindrical sensors
Ø 18 mm
Polyamid
Threaded barrel M18
BSN18
M6947200
Mounting clamp for
cylindrical sensors
Ø 18 mm
PBT
Threaded barrel M18
BST-18B
M6947214
Mounting block with
mechanical lock for
cylindrical sensors
Ø 18 mm
Polyamid
Threaded barrel M18
BST-18N
M6947215
Mounting block
without mechanical
lock for cylindrical
sensors
Ø 18 mm
Polyamid
Threaded barrel M18
QM-18
M6945102
Mounting brackets for
cylindrical sensors
Ø 18 mm
Chrome-plated
brass
Threaded barrel M18
CAP 18-PTFE
A3055
Protective teflon caps
PTFE
Threaded barrel
M18, for embeddable
sensors
CAP-18N-PTFE
A3056
Protective teflon caps
PTFE
Threaded barrel M18,
for nonembeddable
sensors
Mounting Blocks:
• Mounting:
- B version with mechanical lock,
- N version without mechanical lock
• Position of fixing mounting clamps is retained during
replacement of sensors
• Modular structure via mounting accessories
• Universal labelling plates
23
Description
B version
– with mechanical lock
Material
Sensor Types
N version
– without mechanical lock
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Housing
TURCK offers a wide range of accessories
for installation and protection of sensors.
Part Number
ID Number
BST-30B
M6947216
Mounting block with
mechanical lock for
cylindrical sensors
Ø 30 mm
Description
Polyamid
Threaded barrel M30
BST-30N
M6947217
Mounting block
without mechanical
lock for cylindrical
sensors
Ø 30 mm
Polyamid
Threaded barrel M30
QM-30
M6945103
Mounting brackets for
cylindrical sensors
Ø 30 mm
Chrome-plated
brass
Threaded barrel M30
CAP 30-PTFE
A3057
Protective teflon caps
PTFE
Threaded barrel
M30, for embeddable
sensors
CAP 30N-PTFE
A3058
Protective teflon caps
PTFE
Threaded barrel M30,
for nonembeddable
sensors
BST-UH
M6947219
Mounting accessories
for mounting blocks
Polyamid
Threaded barrel M18
Threaded barrel M30
BST-UV
M6947218
Mounting accessories
for mounting blocks
Polyamid
Threaded barrel M18
Threaded barrel M30
Mounting blocks as well as quick mounting
brackets are offered for all cylindrical
versions, diameter 6.5 mm, M8x1,
M12x1, M18x1 and M30x1.5.
Material
For Sensor Types
The JS 025/037 mounting rail facilitates
installation and adjustment of CP40 and
CK40 model sensors.
Protective holders which also simplify
installation of CK40 and CP40 model
sensors offer additional protection against
mechanical damage.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
24
TURCK
RFID Products
BL ident – Accessories
Housing
25
Part Number
ID Number
Description
Material
For Sensor Types
MF-CK40-1S
M6900481
Protective housing for
CK40, single side
Metal
Rectangular CK40
MF-CK40-2S
M6900482
Protective housing for
CK40, angle
Metal
Rectangular CK40
MF-CK40-3S
M6900483
Protective housing for
CK40, U profile
Metal
Rectangular CK40
T-CK40-T-FC
A5202
Protective teflon caps
PTFE
Rectangular CK40
T-CK40-D-FC
A5160
Protective cap, resistant
to high temperatures
Derlin
Rectangular CK40
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Housing
*
Part Number
ID Number
Description
Material
For Sensor Types
SG40/2
M6900369
Temperature resistant
protective housing for
CP40
Ultem
Rectangular CK40
JS 025/037
M69429
Mounting rail for
housing CK40
Stainless steel
Rectangular CK40
DS-R30
M6900512
Spacer ring for data
carrier Ø 30 mm1
Plastic
DS-R50
M6900386
Spacer ring for data
carrier Ø 50 mm*
Plastic
BST-BS
M6947220
Labeling plate for
BST- fixing clamps
Plastic
All
Spacer to provide minimum distance required between data carrier and metal ferrous mounting surface.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
26
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 128 Byte
• EEPROM
Housing
Part Number
Function Principle
TW-R16-B128
The BL ident data carriers (TAGs) can be written and read without contact with appropriate
read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air interface
of a read/write head, the power is transferred inductively and the data transfer initiated.
The read/write interval varies between .157-2.48 in. (4-63 mm).
Part Number
ID Number
TW-R16-B128
M6900501
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
128 Byte
unlimited
105
2 ms/Byte
3 ms/Byte
EEPROM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
27
.4 in (10 mm)
Black
-25 to +85°C (-13 to +185°F)
-25 to +120°C (-13 to +248°F)
IP 68
Epoxyd, molded plastic
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
18 mm - Embeddable
TB-M18-H1147
M7030001
.236
(6)
.157
(4)
.512
(13)
.551
(14)
.709
(18)
2.835
(72)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.472
(12)
.157
(4)
.984
(25)
.827
(21)
1.063
(27)
4.252
(108)
30 mm - Embeddable
TB-M30-H1147
M7030003
.433
(11)
.354
(9)
.866
(22)
.709
(18)
.866
(22)
3.465
(88)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.630
(16)
.354
(9)
1.260
(32)
1.102
(28)
1.417
(36)
5.669
(144)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
.866
(22)
.433
(11)
1.772
(45)
1.260
(32)
1.575
(40)
6.299
(160)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
1.220
(31)
.512
(13)
2.480
(63)
1.968
(50)
2.480
(63)
9.921
(252)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
1.220
(31)
.630
(16)
2.480
(63)
2.835
(72)
3.543
(90)
14.173
(360)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
28
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 128 Byte
• EEPROM
Housing
Part Number
Function Principle
TW-R20-B128
The BL ident data carriers (TAGs) can be written and read without contact with appropriate
read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air interface
of a read/write head, the power is transferred inductively and the data transfer initiated.
The read/write interval varies between .157-2.835 in. (4-72 mm). TAGs available with
EEPROM or FRAM memory.
Part Number
ID Number
TW-R20-B128
M6900502
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
128 Byte
Unlimited
105
2 ms/Byte
3 ms/Byte
EEPROM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
29
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +85°C (-13 to +185°F)
IP 68
Epoxyd
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
18 mm - Embeddable
TB-M18-H1147
M7030001
.236
(6)
.157
(4)
.512
(13)
.630
(16)
.827
(21)
3.307
(84)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.512
(13)
.197
(5)
1.024
(26)
.906
(23)
1.142
(29)
4.567
(116)
30 mm - Embeddable
TB-M30-H1147
M7030003
.472
(12)
.394
(10)
.945
(24)
.748
(19)
.945
(24)
3.780
(96)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.630
(16)
.394
(10)
1.299
(33)
1.102
(28)
1.299
(33)
5.197
(132)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
.945
(24)
.472
(12)
1.929
(49)
1.457
(37)
1.850
(47)
6.299
(160)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
1.299
(33)
.709
(18)
2.638
(67)
2.244
(57)
2.835
(72)
9.921
(252)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
1.417
(36)
.709
(18)
2.835
(72)
3.228
(82)
4.055
(103)
16.220
(412)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
30
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 128 Byte
• EEPROM
Housing
Part Number
Function Principle
TW-R30-B128
The BL ident data carriers (TAGs) can be written and read without contact with appropriate
read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air interface
of a read/write head, the power is transferred inductively and the data transfer initiated.
The read/write interval varies between .236-3.543 in. (6-90 mm). TAGs available with
EEPROM or FRAM memory.
Part Number
ID Number
TW-R30-B128
M6900503
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
128 Byte
Unlimited
105
2 ms/Byte
3 ms/Byte
EEPROM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
31
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +85°C (-13 to +185°F)
IP 68
Epoxyd
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.512
(13)
.236
(6)
1.063
(27)
.945
(24)
1.220
(31)
4.882
(124)
30 mm - Embeddable
TB-M30-H1147
M7030003
.551
(14)
.433
(11)
1.102
(28)
.827
(21)
1.102
(28)
4.409
(112)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.787
(20)
.433
(11)
1.575
(40)
1.260
(32)
1.614
(41)
6.457
(164)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
1.063
(27)
.512
(13)
2.126
(54)
1.693
(43)
2.126
(54)
8.504
(216)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
1.575
(40)
.866
(22)
3.150
(80)
2.520
(64)
3.189
(81)
12.756
(324)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
1.772
(45)
.866
(22)
3.543
(90)
3.661
(93)
4.606
(117)
18.425
(468)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
32
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 128 Byte
• EEPROM
Housing
Part Number
Function Principle
TW-R50-B128
The BL ident data carriers (TAGs) can be written and read without contact with
appropriate read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air
interface of a read/write head, the power is transferred inductively and the data
transfer initiated.
The read/write interval varies between .354-5.669 in. (9-144 mm). TAGs available
with EEPROM or FRAM memory.
Part Number
ID Number
TW-R50-B128
M6900504
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
128 Byte
Unlimited
105
2 ms/Byte
3 ms/Byte
EEPROM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
33
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +85°C (-13 to +185°F)
IP 68
Epoxyd
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.709
(18)
.354
(9)
1.417
(36)
1.535
(39)
1.929
(49)
7.717
(196)
30 mm - Embeddable
TB-M30-H1147
M7030003
.709
(18)
.512
(13)
1.417
(36)
1.220
(31)
1.535
(39)
6.142
(156)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
1.063
(27)
.512
(13)
1.260
(32)
1.968
(50)
2.480
(63)
9.921
(252)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
1.575
(40)
.866
(22)
1.772
(45)
2.520
(64)
3.189
(81)
12.756
(324)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
2.283
(58)
1.220
(31)
4.606
(117)
3.661
(93)
4.606
(117)
18.425
(468)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
2.835
(72)
1.417
(36)
5.669
(144)
4.803
(122)
6.024
(153)
24.094
(612)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
34
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 2 kByte
• FRAM
Housing
Part Number
Function Principle
TW-R20-K2
The BL ident data carriers (TAGs) can be written and read without contact with appropriate
read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air interface
of a read/write head, the power is transferred inductively and the data transfer initiated.
The read/write interval varies between .157-2.520 in. (4-64 mm). TAGs available with
EEPROM or FRAM memory.
Part Number
ID Number
TW-R20-K2
M6900505
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
2 kByte
Unlimited
1010
0.5 ms/Byte
0.5 ms/Byte
FRAM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
35
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +85°C (-13 to +185°F)
IP 68
PA6
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
18 mm - Embeddable
TB-M18-H1147
M7030001
.197
(5)
.157
(4)
.433
(11)
.433
(11)
.709
(18)
2.835
(72)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.433
(11)
.157
(4)
.906
(23)
.551
(14)
1.024
(26)
4.094
(104)
30 mm - Embeddable
TB-M30-H1147
M7030003
.394
(10)
.236
(6)
.827
(21)
.630
(16)
.827
(21)
3.307
(84)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.551
(14)
.315
(8)
1.142
(29)
1.024
(26)
1.142
(29)
4.567
(116)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
.866
(22)
.394
(10)
1.732
(44)
1.299
(33)
1.654
(42)
6.614
(168)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
1.181
(30)
.630
(16)
2.362
(60)
2.008
(51)
2.520
(64)
9.842
(250)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
1.260
(32)
.630
(16)
2.520
(64)
2.913
(74)
3.701
(94)
14.803
(376)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
36
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 2 kByte
• FRAM
Housing
Part Number
Function Principle
TW-R30-K2
The BL ident data carriers (TAGs) can be written and read without contact with appropriate
read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air interface
of a read/write head, the power is transferred inductively and the data transfer initiated.
The read/write interval varies between .236-3.189 in. (6-81 mm). TAGs available with
EEPROM or FRAM memory.
Part Number
ID Number
TW-R30-K2
M6900506
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
2 kByte
Unlimited
1010
0.5 ms/Byte
0.5 ms/Byte
FRAM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
37
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +85°C (-13 to +185°F)
IP 68
PA6
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
Distance
minimum
between two
read/write
heads1
inches
(mm)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.472
(12)
.236
(6)
.945
(24)
.827
(21)
1.063
(27)
108
30 mm - Embeddable
TB-M30-H1147
M7030003
.472
(12)
.354
(9)
.984
(25)
.748
(19)
.984
(25)
3.937
(100)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.709
(18)
.394
(10)
1.417
(36)
1.102
(28)
1.417
(36)
5.669
(144)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
.945
(24)
.433
(11)
1.890
(48)
1.496
(38)
1.890
(48)
7.559
(192)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
1.417
(36)
.787
(20)
2.835
(72)
2.283
(58)
2.835
(72)
11.338
(288)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
1.575
(40)
.787
(20)
3.189
(81)
3.307
(84)
107
428
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
38
TURCK
RFID Products
RFID System - Data Carrier (Read/Write)
• Data Carrier (Read/Write)
• Memory Size 2 kByte
• FRAM
Housing
Part Number
Function Principle
TW-R50-K2
The BL ident data carriers (TAGs) can be written and read without contact with
appropriate read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air
interface of a read/write head, the power is transferred inductively and the data
transfer initiated.
The read/write interval varies between .315-5.079 in. (8-129 mm). TAGs available
with EEPROM or FRAM memory.
Part Number
ID Number
TW-R50-K2
M6900507
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
2 kByte
Unlimited
1010
0.5 ms/Byte
0.5 ms/Byte
FRAM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
39
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +85°C (-13 to +185°F)
IP 68
PA6
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
18 mm - Nonembeddable
TN-M18-H1147
M7030002
.630
(16)
.315
(8)
1.260
(32)
.827
(21)
1.732
(44)
6.929
(176)
30 mm - Embeddable
TB-M30-H1147
M7030003
.630
(16)
.472
(12)
1.260
(32)
.945
(24)
1.378
(35)
5.512
(140)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.945
(24)
.472
(12)
1.890
(48)
1.772
(45)
2.205
(56)
8.819
(224)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
1.417
(36)
.748
(19)
2.835
(72)
2.244
(57)
2.835
(72)
11.339
(288)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
2.047
(52)
1.063
(27)
4.134
(105)
3.268
(83)
4.134
(105)
16.535
(420)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
2.520
(64)
1.181
(30)
5.079
(129)
4.370
(111)
5.433
(138)
21.732
(552)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
40
TURCK
RFID Products
RFID System - High Temperature Data Carrier (Read/Write)
• High Temperature Data Carrier (Read/Write)
• For High Temperatures Up to 210°C (410°F)
• Memory Size 128 Byte
• EEPROM
Housing
Part Number
Function Principle
TW-R50-90-HT-B128
The BL ident data carriers (TAGs) can be written and read without contact with
appropriate read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air
interface of a read/write head, the power is transferred inductively and the data
transfer initiated.
The read/write interval varies between .512-5.669 in. (13-144 mm). TAGs available
with EEPROM or FRAM memory.
Part Number
ID Number
TW-R50-90-HT-B128
M1542326
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
128 Byte
Unlimited
105
2 ms/Byte
3 ms/Byte
EEPROM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +210°C (-13 to +410°F)*
IP 68
PA66
* Can perform at 210°C (410°F) for 30 minutes.
41
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
30 mm - Embeddable
TB-M30-H1147
M7030003
.709
(18)
.512
(13)
1.417
(36)
1.220
(31)
1.535
(39)
6.142
(156)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
1.063
(27)
.512
(13)
2.126
(54)
1.968
(50)
2.480
(63)
9.921
(252)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
1.575
(40)
.866
(22)
3.189
(81)
2.520
(64)
3.189
(81)
12.756
(324)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
2.283
(58)
1.220
(31)
4.606
(117)
3.661
(93)
4.606
(117)
18.425
(468)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
2.835
(72)
1.417
(36)
5.669
(144)
4.803
(122)
6.024
(153)
24.094
(612)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
42
TURCK
RFID Products
RFID System - High Temperature Data Carrier (Read/Write)
• High Temperature Data Carrier (Read/Write)
• For High Temperatures Up to 210°C (410°F)
• Memory Size 2 kByte
• FRAM
Housing
Part Number
Function Principle
TW-R50-90-HT-K2
The BL ident data carriers (TAGs) can be written and read without contact with
appropriate read/write heads. The operating frequency is 13.56 MHz.
The data carriers are passive, i.e. do not have a battery. When they enter the air
interface of a read/write head, the power is transferred inductively and the data
transfer initiated.
The read/write interval varies between .472-5.079 (12-129 mm). TAGs available
with EEPROM or FRAM memory.
Part Number
ID Number
TW-R50-90-HT-K2
M1542329
Storage Data
Operating frequency
Memory size
Number of read operations
Number of write operations
Read time (typical)
Write time (typical)
Memory organization
13.56 MHz
2 kByte
Unlimited
105
0.5 ms/Byte
0.5 ms/Byte
FRAM
Installation Guidelines
Minimum distance between data carrier
and metal surface
(see accessories on page 26 for spacers)
General Data
Color
Storage temperature
Ambient temperature
Degree of protection (IEC 60529/EN 60529)
Housing material
.4 in (10 mm)
Black
-40 to +85°C (-40 to +185°F)
-25 to +210°C (-13 to +410°F)*
IP 68
PA66
* Can perform at 210°C (410°F) for 30 minutes.
43
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Read/Write Heads
Housing
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
30 mm - Embeddable
TB-M30-H1147
M7030003
.630
(16)
.472
(12)
1.260
(32)
.945
(24)
1.378
(35)
5.512
(140)
30 mm - Nonembeddable
TN-M30-H1147
M7030004
.945
(24)
.472
(12)
1.890
(48)
1.772
(45)
2.205
(56)
8.819
(224)
40 mm - Nonembeddable
TN-CK40-H1147
M7030006
1.417
(36)
.748
(19)
2.835
(72)
2.244
(57)
2.835
(72)
11.339
(288)
80 mm - Nonembeddable
TN-Q80-H1147
M7030007
2.047
(52)
1.063
(27)
4.134
(105)
3.268
(83)
4.134
(105)
16.535
(420)
32 mm - Nonembeddable
TN-S32XL-H1147
M7030008
2.520
(64)
1.181
(30)
5.079
(129)
4.370
(111)
5.394
(137)
21.732
(552)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
44
TURCK
RFID Products
RFID System - Read/Write Head
• Threaded Barrel, M18x1, Chrome Plated Brass
• Flush Mounting
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TB-M18-H1147
The BL ident read/write head (transceiver) is used to exchange data with the data
carrier (TAG). Together they form an air interface whose size depends on the
combination of transceiver and TAG. The data carriers are passive. When they
enter the air interface of the transceiver, the power from the transceiver is transferred
inductively and data transfer completed.
BL ident TAGs on the following page can be combined with this BL ident transceiver.
The read/write interval varies between .157-.433 in. (4-11 mm).
TAGs available with EEPROM or FRAM memory.
Part Number
ID Number
TB-M18-H1147
M7030001
Mounting Mode
Ambient temperature
Flush
-25 to +210°C (-13 to +410°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Threaded barrel, M18x1
Metal, CuZn, chrome plated
Plastic, PA12-GF30
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
45
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
.236
(6)
.157
(4)
.512
(13)
.551
(14)
.709
(18)
2.835
(72)
2
TW-R20-B128
M6900502
.236
(6)
.157
(4)
.512
(13)
.630
(16)
.827
(21)
3.307
(84)
2
TW-R20-K2
M6900505
.197
(5)
.157
(4)
.433
(11)
.433
(11)
.709
(18)
2.835
(72)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
46
TURCK
RFID Products
RFID System - Read/Write Head
• Threaded Barrel, M18x1, Chrome Plated Brass
• Flush Mounting
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TN-M18-H1147
The BL ident read/write head (transceiver) is used to exchange data with the
data carrier (TAG). Together they form an air interface whose size depends on
the combination of transceiver and TAG. The data carriers are passive. When
they enter the air interface of the transceiver, the power from the transceiver is
transferred inductively and data transfer completed.
BL ident TAGs on the following page can be combined with this BL ident
transceiver. The read/write interval varies between .157-1.417 in. (4-36 mm).
TAGs available with EEPROM or FRAM memory.
Part Number
ID Number
TN-M18-H1147
M7030002
Mounting Mode
Ambient temperature
Non flush
-25 to +70°C (-13 to +158°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Threaded barrel, M18 x 1
Metal, CuZn, chrome plated
Plastic, PA12-GF30
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
47
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
3
4
1
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
.472
(12)
.157
(4)
.984
(25)
.827
(21)
1.063
(27)
4.252
(108)
2
TW-R20-B128
M6900502
.512
(13)
.197
(5)
1.024
(26)
.906
(23)
1.142
(29)
4.567
(116)
3
TW-R30-B128
M6900503
.512
(13)
.236
(6)
1.063
(27)
.945
(24)
1.220
(31)
4.882
(124)
4
TW-R50-B128
M6900504
.709
(18)
.354
(9)
1.417
(36)
1.535
(39)
1.929
(49)
7.717
(196)
2
TW-R20-K2
M6900505
.433
(11)
.157
(4)
.906
(23)
.551
(14)
1.024
(26)
4.094
(104)
3
TW-R30-K2
M6900506
.472
(12)
.236
(6)
.945
(24)
.827
(21)
1.063
(27)
4.252
(108)
4
TW-R50-K2
M6900507
.630
(16)
.315
(8)
1.260
(32)
.827
(21)
1.732
(44)
6.929
(176)
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
48
TURCK
RFID Products
RFID System - Read/Write Head
• Threaded Barrel, M30x1.5, Chrome Plated Brass
• Flush Mounting
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TB-M30-H1147
The BL ident read/write head (transceiver) is used to exchange data with the
data carrier (TAG). Together they form an air interface whose size depends on
the combination of transceiver and TAG. The data carriers are passive. When
they enter the air interface of the transceiver, the power from the transceiver is
transferred inductively and data transfer completed.
BL ident TAGs on the following page can be combined with this BL ident
transceiver. The read/write interval varies between .354-1.417 in. (9-36 mm).
TAGs available with EEPROM or FRAM memory.
Part Number
ID Number
TB-M30-H1147
M7030003
Mounting Mode
Ambient temperature
Flush
-25 to +70°C (-13 to +158°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Threaded barrel, M30 x 1.5
Metal, CuZn, chrome plated
Plastic, PA12-GF30
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
49
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
3
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
.433
(11)
.354
(9)
.866
(22)
.669
(17)
.866
(22)
3.465
(88)
2
TW-R20-B128
M6900502
.472
(12)
.394
(10)
.945
(24)
.748
(19)
.945
(24)
3.780
(96)
3
TW-R30-B128
M6900503
.551
(14)
.433
(11)
1.102
(28)
.827
(21)
1.102
(28)
4.409
(112)
4
TW-R50-B128
M6900504
.709
(18)
.512
(13)
1.417
(36)
1.220
(31)
1.535
(39)
6.142
(156)
2
TW-R20-K2
M6900505
.394
(10)
.236
(6)
.827
(21)
.630
(16)
.827
(21)
3.307
(84)
3
TW-R30-K2
M6900506
.472
(12)
.354
(9)
.984
(25)
.748
(19)
.984
(25)
3.937
(100)
4
TW-R50-K2
M6900507
.630
(16)
.472
(12)
1.260
(32)
.945
(24)
1.378
(35)
5.512
(140)
5
TW-R50-90-HT-B128
M1542326
.709
(18)
.512
(13)
1.417
(36)
1.220
(31)
1.535
(39)
6.142
(156)
5
TW-R50-90-HT-K2
M1542329
.630
(16)
.472
(12)
1.260
(32)
.945
(24)
1.378
(35)
5.512
(140)
4
5
1
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F); (-40 to +210°C (-40 to +410°F) for TW-R*-HT....).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
50
TURCK
RFID Products
RFID System - Read/Write Head
• Threaded Barrel, M30x1.5, Chrome Plated Brass
• Flush Mounting
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TN-M30-H1147
The BL ident read/write head (transceiver) is used to exchange data with the
data carrier (TAG). Together they form an air interface whose size depends on
the combination of transceiver and TAG. The data carriers are passive. When
they enter the air interface of the transceiver, the power from the transceiver is
transferred inductively and data transfer completed.
BL ident TAGs on the following page can be combined with this BL ident
transceiver. The read/write interval varies between .354-2.126 in. (9-54 mm).
TAGs available with EEPROM or FRAM memory.
Part Number
ID Number
TN-M30-H1147
M7030004
Mounting Mode
Ambient temperature
Flush
-25 to +70°C (-13 to +158°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Threaded barrel, M30x1
Metal, CuZn, chrome plated
Plastic, PA12-GF30
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
51
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
3
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
.630
(16)
.354
(9)
1.260
(32)
1.102
(28)
1.417
(36)
5.669
(144)
2
TW-R20-B128
M6900502
.630
(16)
.394
(10)
1.299
(33)
1.102
(28)
1.299
(33)
5.197
(132)
3
TW-R30-B128
M6900503
.787
(20)
.433
(11)
1.575
(40)
1.260
(32)
1.614
(41)
6.457
(164)
4
TW-R50-B128
M6900504
1.063
(27)
.512
(13)
2.126
(54)
1.968
(50)
2.480
(63)
9.921
(252)
2
TW-R20-K2
M6900505
.551
(14)
.315
(8)
1.142
(29)
1.024
(26)
1.142
(29)
4.567
(116)
3
TW-R30-K2
M6900506
.709
(18)
.394
(10)
1.417
(36)
1.102
(28)
1.417
(36)
5.669
(144)
4
TW-R50-K2
M6900507
.945
(24)
.472
(12)
1.890
(48)
1.772
(45)
2.205
(56)
8.819
(224)
5
TW-R50-90-HT-B128
M1542326
1.063
(27)
.512
(13)
2.126
(54)
1.968
(50)
2.480
(63)
9.921
(252)
5
TW-R50-90-HT-K2
M1542329
.945
(24)
.472
(12)
1.890
(48)
1.772
(45)
2.205
(56)
8.819
(224)
4
5
1
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F); (-40 to +210°C (-40 to +410°F) for TW-R*-HT....).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
52
TURCK
RFID Products
RFID System - Read/Write Head
• Rectangular, 40 mm High
• 5-positions Turnable
• Plastic, PBT-GF30-V0
• Partial Embedding
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TN-CK40-H1147
The BL ident read/write head (transceiver) is used to exchange data with the
data carrier (TAG). Together they form an air interface whose size depends on
the combination of transceiver and TAG. The data carriers are passive. When
they enter the air interface of the transceiver, the power from the transceiver is
transferred inductively and data transfer completed.
BL ident TAGs on the following page can be combined with this BL ident
transceiver. The read/write interval varies between .433-3.184 in. (11-81 mm).
TAGs available with EEPROM or FRAM memory.
Part Number
ID Number
TN-CK40-H1147
M7030006
Mounting Mode
Ambient temperature
Non flush, flush mounting possible
-25 to +70°C (-13 to +158°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Rectangular, CK40
Plastic, PBT-GF30-V0, black
Plastic, PBT-GF30-V0, yellow
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Accessories
Fixing clamp BS4-CK40 (included in delivery)
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
53
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
3
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
.866
(22)
.433
(11)
1.772
(45)
1.260
(32)
1.575
(40)
6.299
(160)
2
TW-R20-B128
M6900502
.945
(24)
.472
(12)
1.929
(49)
1.457
(37)
1.850
(47)
7.402
(188)
3
TW-R30-B128
M6900503
1.063
(27)
.512
(13)
2.126
(54)
1.693
(43)
2.126
(54)
8.504
(216)
4
TW-R50-B128
M6900504
1.575
(40)
.866
(22)
3.189
(81)
2.520
(64)
3.189
(81)
12.756
(324)
2
TW-R20-K2
M6900505
.866
(22)
.394
(10)
1.732
(44)
1.299
(33)
1.654
(42)
6.614
(168)
3
TW-R30-K2
M6900506
.945
(24)
.433
(11)
1.890
(48)
1.496
(38)
1.890
(48)
7.559
(192)
4
TW-R50-K2
M6900507
1.417
(36)
.748
(19)
2.835
(72)
2.244
(57)
2.835
(72)
11.339
(288)
5
TW-R50-90-HT-B128
M1542326
1.575
(40)
.866
(22)
3.189
(81)
2.520
(64)
3.189
(81)
12.756
(324)
5
TW-R50-90-HT-K2
M1542329
1.417
(36)
.748
(19)
2.835
(72)
2.244
(57)
2.835
(72)
11.339
(288)
4
5
1
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F); (-40 to +210°C (-40 to +410°F) for TW-R*-HT....).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
54
TURCK
RFID Products
RFID System - Read/Write Head
• Rectangular, 40 mm High
• 5-positions Turnable
• Plastic, PBT-GF30-V0
• Partial Embedding
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TN-Q80-H1147
The BL ident read/write head (transceiver) is used to
exchange data with the data carrier (TAG). Together they
form an air interface whose size depends on the combination
of transceiver and TAG. The data carriers are passive. When
they enter the air interface of the transceiver, the power from
the transceiver is transferred inductively and data transfer
completed.
BL ident TAGs on the following page can be combined
with this BL ident transceiver. The read/write interval varies
between .512-4.606 in. (13-117 mm). TAGs available with
EEPROM or FRAM memory.
Part Number
ID Number
TN-Q80-H1147
M7030007
Mounting Mode
Ambient temperature
Non flush, flush mounting possible
-25 to +70°C (-13 to +158°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Rectangular, CK40
Plastic, PBT-GF30-V0, yellow
Plastic, PBT-GF30-V0, yellow
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
55
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
3
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
1.220
(31)
.512
(13)
2.480
(63)
1.968
(50)
2.480
(63)
9.921
(252)
2
TW-R20-B128
M6900502
1.299
(33)
.709
(18)
2.638
(67)
2.244
(57)
2.835
(72)
11.339
(288)
3
TW-R30-B128
M6900503
1.575
(40)
.866
(22)
3.150
(80)
2.520
(64)
3.189
(81)
12.756
(324)
4
TW-R50-B128
M6900504
2.283
(58)
1.220
(31)
4.606
(117)
3.661
(93)
4.606
(117)
18.425
(468)
2
TW-R20-K2
M6900505
1.181
(30)
.630
(16)
2.362
(60)
2.008
(51)
2.520
(64)
10.079
(256)
3
TW-R30-K2
M6900506
1.417
(36)
.787
(20)
2.835
(72)
2.283
(58)
2.835
(72)
11.339
(288)
4
TW-R50-K2
M6900507
2.047
(52)
1.063
(27)
4.134
(105)
3.268
(83)
4.134
(105)
16.535
(420)
5
TW-R50-90-HT-B128
M1542326
2.283
(58)
1.220
(31)
4.606
(117)
3.661
(93)
4.606
(117)
18.425
(468)
5
TW-R50-90-HT-K2
M1542329
2.047
(52)
1.063
(27)
4.134
(105)
3.268
(83)
4.134
(105)
16.535
(420)
4
5
1
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F); (-40 to +210°C (-40 to +410°F) for TW-R*-HT....).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
56
TURCK
RFID Products
RFID System - Read/Write Head
• Ring Type, 32 mm High
• Plastic, ABS
• Non-flush Mountable
• Power Supply (24 VDC) and Function via BL ident Interfaces
• Connector (M12) eurofast®, Connection via BL ident Connecting Cable
Housing
Part Number
Function Principle
TN-S32XL-H1147
The BL ident read/write head (transceiver) is used to
exchange data with the data carrier (TAG). Together they
form an air interface whose size depends on the combination
of transceiver and TAG. The data carriers are passive. When
they enter the air interface of the transceiver, the power from
the transceiver is transferred inductively and data transfer
completed.
BL ident TAGs on the following page can be combined
with this BL ident transceiver. The read/write interval varies
between .630-5.669 in. (16-144 mm). All TAGs available
with EEPROM or FRAM memory.
Part Number
ID Number
TN-S32XL-H1147
M7030008
Mounting Mode
Ambient temperature
Non flush
-25 to +70°C (-13 to +158°F)
Data Transfer
Output function
Operating frequency
Inductive
4-wire, write/read
13.56 MHz
Housing
Ring inner diameter
Housing material
Material active face
Connection
Vibration resistance
Shock resistance
Protection
Ring type, S32
100 mm
Plastic
Plastic, ABS, yellow
Connector, M12x1
55 Hz (1 mm)
30 g (11 ms)
IP 67
Power On Indication
Read/write head off
TAG with air interface
LED solid
LED .5 Hz
LED 3 Hz
Wiring
Maximum cable length
50 m
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
57
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Associated Data Carrier
Housing
Fig.
Part Number
ID Number
Read/Write Range
Zone Width
Length
1
2
3
Distance
minimum
between two
read/write
heads1
Recomm.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
min.
inches
(mm)
max.
inches
(mm)
inches
(mm)
1
TW-R16-B128
M6900501
1.220
(31)
.630
(16)
2.480
(63)
2.835
(72)
3.543
(90)
14.173
(360)
2
TW-R20-B128
M6900502
1.417
(36)
.709
(18)
2.835
(72)
3.228
(82)
4.055
(103)
16.220
(412)
3
TW-R30-B128
M6900503
1.772
(45)
.866
(22)
3.543
(90)
3.661
(93)
4.606
(117)
18.425
(468)
4
TW-R50-B128
M6900504
2.835
(72)
1.417
(36)
5.669
(144)
4.803
(122)
6.024
(153)
24.094
(612)
2
TW-R20-K2
M6900505
1.260
(32)
.630
(16)
2.520
(64)
2.913
(74)
3.701
(94)
14.803
(376)
3
TW-R30-K2
M6900506
1.575
(40)
.787
(20)
3.189
(81)
3.307
(84)
4.213
(107)
16.850
(428)
4
TW-R50-K2
M6900507
2.520
(64)
1.181
(30)
5.079
(129)
4.370
(111)
5.433
(138)
21.732
(552)
5
TW-R50-90-HT-B128
M1542326
2.835
(72)
1.417
(36)
5.669
(144)
4.803
(122)
6.024
(153)
24.094
(612)
5
TW-R50-90-HT-K2
M1542329
2.520
(64)
1.181
(30)
5.079
(129)
4.370
(111)
5.394
(137)
21.732
(552)
4
5
1
Smaller intervals are possible by alternating switching the read/write heads on and off with software.
10 mm air gap required when mounting to ferrous metal. See accessories on page 26 for spacers.
Ambient temperature: -25 to +85°C (-13 to +185°F); (-40 to +210°C (-40 to +410°F) for TW-R*-HT....).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
58
TURCK
RFID Products
®
RFID System - Interface for PROFIBUS -DP (DPV1) - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• Two 5-pin Inverse-Coded M12 (eurofast®) Connectors for Fieldbus Connection
• 5-pin 7/8" (minifast®) Connector for Power Supply
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
• Compatible with Siemens S7-300 PLC's*
Housing
Part Number
ID Number
Function Principle
BL67-GW-DPV1
M6827232
The BL ident interface serves
for connection of the BL ident
system to the higher priority
fieldbus. 2, 4, 6 or 8 read/
write heads can be connected,
depending on the type of unit.
Data exchange is accomplished
in parallel with the individual
read/write heads.
* Other processors may be supported. Contact factory for assistance or check www.turck.com.
See Fieldbus I/O and Media catalog for specific gateway specifications.
59
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-GW-DPV1
M6827232
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Fieldbus addressing
Service interface
Fieldbus connection
Power supply connection
Fieldbus terminator
1 to 125
3 decimal rotary switches
PS/2 socket for I/O-ASSISTANT
2 x M12, 5-pole, inverse coded
5-pole, 7/8“ (minifast®)-connector
External
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast®) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95% (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
Pinouts
minifast
eurofast
Male
1 = Gnd
2 = Gnd
3 = PE
4 = V1
5 = V0
Male
Female
5-Pin
5-Pin
1 = Shield
2 = V+
3 = V4 = CAN_H
5 = CAN_L
5-Pin
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
60
TURCK
RFID Products
®
RFID System - Interface for PROFIBUS -DP (DPV1) - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• Programmable According to IEC 61131-3 with CoDeSys
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• One 4-pin M12 (eurofast®) Connector, D-coded, for Fieldbus Connection
• 5-pin 7/8" (minifast®) Connector for Power Supply
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
Housing
Part Number
BL67-PG-DP
ID Number
Function Principle
M6827240
The BL ident programmable
interface serves for connection of
the BL ident system to the higher
priority fieldbus. By using a
programmable gateway, network
and PLC usage will decrease. 2,
4, 6 or 8 read/write heads can
be connected, depending on the
type of unit. Data exchange is
accomplished in parallel with the
individual read/write heads.
See Fieldbus I/O and Media catalog for specific gateway specifications.
61
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-PG-DP
M6827240
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
600 mA + 30 mA/module (2 channel)
Fieldbus Address Range
Fieldbus addressing
Service interface
Fieldbus connection
Power supply connection
Fieldbus terminator
1 to 125
3 decimal rotary switches
PS/2 socket for I/O-ASSISTANT
2 x M12, 5-pole, inverse coded
5-pole, 7/8“ (minifast®)-connector
External
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast®) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95% (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
PLC Data
Programming
Released for CoDeSys Version
Programming languages
Application tasks
Number of POUs
Programming interface
CoDeSys V2.3
V 2.3.5.8
IEC 61131-3 (IL, LD, FBD, SFC, ST)
1
1024
RS232 interface, Ethernet
RISC
32 bit
< 1 ms for 1000 IL commands (without I/O cycle)
Yes
512 kByte
512 kByte
4 kByte
4 kByte
16 kByte
Cycle time
Real time clock
Program memory
Data memory
Input data
Output data
Non-volatile memory
Pinouts
minifast
eurofast
Male
1 = Gnd
2 = Gnd
3 = PE
4 = V1
5 = V0
Male
Female
5-Pin
5-Pin
1 = 5 VDC*
2 = BUS_A
3 = Gnd
4 = BUS_B
5 = Shield
5-Pin
* Female Connector only
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
62
TURCK
RFID Products
RFID System - Interface for DeviceNet™ - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• Two 5-pin 7/8" (minifast®) Connectors for Fieldbus Connection
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
• Compatible with Allen-Bradley Controllogix and SLC500 Platforms*
Housing
Part Number
ID Number
Function Principle
BL67-GW-DN
M6827183
The BL ident interface
serves for connection of
the BL ident system to the
higher priority fieldbus.
2, 4, 6 or 8 read/write
heads can be connected,
depending on the type of
unit. Data exchange is
accomplished in parallel
with the individual read/
write heads.
* Other processors may be supported. Contact factory for assistance or check www.turck.com.
See Fieldbus I/O and Media catalog for specific gateway specifications.
63
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-GW-DN
M6827183
Power Supply
Permissible range
Rated current from module bus
24 VDC
11 to 26 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Fieldbus addressing
Service interface
Fieldbus connection
Power supply connection
Fieldbus terminator
1 to 63
2 decimal rotary switches
PS/2 socket for I/O-ASSISTANT
2 x 7/8" (minifast®), 5-pole
From DeviceNet™ cable
External
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast®) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
Pinouts
minifast
Male
Female
5-Pin
5-Pin
1 = Shield
2 = V+
3 = V4 = CAN_H
5 = CAN_L
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
64
TURCK
RFID Products
RFID System - Interface for Modbus-TCP - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• Programmable According to IEC 61131-3 with CoDeSys
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• One 4-Pin M12 (eurofast®) Connector, D-Coded, for Fieldbus Connection
• One 5-Pin 7/8" (minifast®) Connector for Power Supply
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
Housing
Part Number
ID Number
Function Principle
BL67-PG-EN
M6827241
The BL ident programmable
interface serves for connection
of the BL ident system to
the higher priority fieldbus.
By using a programmable
gateway, network and PLC
usage will decrease. 2, 4, 6
or 8 read/write heads can be
connected, depending on the
type of unit. Data exchange
is accomplished in parallel
with the individual read/write
heads.
See Fieldbus I/O and Media catalog for specific gateway specifications.
65
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-PG-EN
M6827241
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 socket for I/O-ASSISTANT
M12 (eurofast®) -Buchse, 4-pole, D-coded
5-pole, 7/8“ (minifast®) -connector
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
PLC Data
Programming
Released for CoDeSys Version
Programming languages
Application tasks
Number of POUs
Programming interface
Cycle time
Real time clock
Program memory
Data memory
Input data
Output data
Non-volatile memory
CoDeSys V2.3
V 2.3.5.8
IEC 61131-3 (IL, LD, FBD, SFC, ST)
1
1024
RS232 interface, Ethernet
RISC
32 bit
< 1 ms for 1000 IL commands (without I/O cycle)
Yes
512 kByte
512 kByte
4 kByte
4 kByte
16 kByte
Pinouts
minifast
eurofast
Male
Female
1 = Gnd
2 = Gnd
3 = PE
4 = V1
5 = V0
1 = TD+
2 = RD+
3 = TD4 = RD
5-Pin
4-Pin
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
66
TURCK
RFID Products
RFID System - Interface for PROFINET IO - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• One 4-Pin M12 (eurofast®) Connector, D-Coded, for Fieldbus Connection
• One 5-Pin 7/8" (minifast®) Connector for Power Supply
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
Housing
Part Number
BL67-GW-EN-PN
ID Number
Function Principle
M6827228
The BL ident interface serves
for connection of the BL
ident system to the higher
priority fieldbus. 2, 4, 6
or 8 read/write heads can
be connected, depending
on the type of unit. Data
exchange is accomplished in
parallel with the individual
read/write heads.
See Fieldbus I/O and Media catalog for specific gateway specifications.
67
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-GW-EN-PN
M6827228
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
PROFINET conform or with Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 female connector for I/O-ASSISTANT
M12 (eurofast®) -female connector, 4-pole, D-coded
5-pole, 7/8“(minifast®) -connector
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
Pinouts
minifast
eurofast
Male
Female
1 = Gnd
2 = Gnd
3 = PE
4 = V1
5 = V0
1 = TD+
2 = RD+
3 = TD4 = RD
5-Pin
4-Pin
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
68
TURCK
RFID Products
RFID System - Interface for EtherNet/IP - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• One 4-Pin M12 (eurofast®) Connector, D-Coded, for Fieldbus Connection
• One 5-Pin 7/8" (minifast®) Connector for Power Supply
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
• Compatible with Allen-Bradley Controllogix Platform*
Housing
Part Number
ID Number
Function Principle
BL67-GW-EN-IP
M6827229
The BL ident interface serves
for connection of the BL
ident system to the higher
priority fieldbus. 2, 4, 6
or 8 read/write heads can
be connected, depending
on the type of unit. Data
exchange is accomplished in
parallel with the individual
read/write heads.
* Other processors may be supported. Contact factory for assistance or check www.turck.com.
See Fieldbus I/O and Media catalog for specific gateway specifications.
69
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-GW-EN-IP
M6827229
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 socket for I/O-ASSISTANT
M12 (eurofast®) -Buchse, 4-pole, D-coded
5-pole, 7/8“(minifast®) -connector
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidty
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
Pinouts
minifast
eurofast
Male
Female
1 = Gnd
2 = Gnd
3 = PE
4 = V1
5 = V0
1 = TD+
2 = RD+
3 = TD4 = RD
5-Pin
4-Pin
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
70
TURCK
RFID Products
RFID System - Interface for EtherNet/IP - IP 67
• Connection of Up to 8 BL ident Read/Write Heads
• Programmable According to IEC 61131-3 with CoDeSys
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• One 4-Pin M12 (eurofast®) Connector, D-Coded, for Fieldbus Connection
• One 5-Pin 7/8" (minifast®) Connector for Power Supply
• M12 (eurofast) Connector for Connection of Read/Write Heads Using BL ident
Connecting Cable
Housing
Part Number
BL67-PG-EN-IP
ID Number
Function Principle
M6827246
The BL ident programmable
interface serves for
connection of the BL
ident system to the higher
priority fieldbus. By using
a programmable gateway
network and PLC usage
will decrease. 2, 4, 6 or
8 read/write heads can be
connected, depending on the
type of unit. Data exchange
is accomplished in parallel
with the individual read/write
heads.
See Fieldbus I/O and Media catalog for specific gateway specifications.
71
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-PG-EN-IP
M6827246
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 socket for I/O-ASSISTANT
M12 (eurofast®) -Buchse, 4-pole, D-coded
5-pole, 7/8“(minifast®) -connector
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
M12 (eurofast) female connector
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidty
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
PLC Data
Programming
Released for CoDeSys Version
Programming languages
Application tasks
Number of POUs
Programming interface
Cycle time
Real time clock
Program memory
Data memory
Input data
Output data
Non-volatile memory
CoDeSys V2.3
V 2.3.5.8
IEC 61131-3 (IL, LD, FBD, SFC, ST)
1
1024
RS232 interface, Ethernet
RISC
32 bit
< 1 ms for 1000 IL commands (without I/O cycle)
Yes
512 kByte
512 kByte
4 kByte
4 kByte
16 kByte
Pinouts
minifast
eurofast
Male
Female
1 = Gnd
2 = Gnd
3 = PE
4 = V1
5 = V0
1 = TD+
2 = RD+
3 = TD4 = RD
5-Pin
4-Pin
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
72
TURCK
RFID Products
RFID System - Standard RFID Module
• Acyclical Exchange of Data
• Degree of Protection IP 67
• LEDs for Display of Status and Diagnostics
• Electronics Galvanically Isolated From the Field Level Via Opto Couplers
• Connection of 2 BL ident Read/Write Heads
Housing
73
Part Number
ID Number
Function Principle
BL67-2RFID-A
M6827225
The BL ident interfaces can be fitted with
additional read/write head connections using
RFID extension modules. The extension
modules are plugged onto purely passive base
modules. The field devices are connected via
the base modules.
Depending on the expansion stage 2, 4, 6 or
8 read/write heads per BL ident interface can
be connected.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-2RFID-A
M6827225
Number of Channels
Nominal voltage Vi
Rated current from field supply
Rated current from module bus
Power loss, typical
2
24 VDC
<100 mA
<30 mA
<1 W
Inputs/Outputs
Transmission rate
Cable length
115.2 kbps
50 m
Electrical isolation of electronics and field level via opto couplers
Simultaneity factor
1
Sensor supply
0.5 A per channel, short-circuit proof
Number of Diagnostic Bytes
Number of parameter bytes
Number of input bytes
Number of output bytes
4
8
4
4
Dimensions (L x W x H)
Operating temperature
Storage temperature
Relative humidity
Vibration test
91 x 32 x 59 mm
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95% (internal), Level RH-2, no condensation (at 45°C (113°F) storage)
Acc. to EN 61131
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
74
TURCK
RFID Products
RFID System - RFID Module for DPV0 PLC's
• For Use With the Gateway BL67-GW-DPV1 in DPV0 Mode
• Cyclical Exchange of Data
• Degree of Protection IP 67
• LEDs for Display of Status and Diagnostics
• Electronics Galvanically Isolated From the Field Level Via Opto Couplers
• Connection of 2 BL ident Read/Write Heads
• Designed for Profibus DPV0 Systems
Housing
75
Part Number
ID Number
Function Principle
BL67-2RFID-C
M6827238
The BL ident interfaces can be fitted with
additional read/write head connections using RFID
extension modules. The extension modules are
plugged onto purely passive base modules. The
field devices are connected via the base modules.
Depending on the expansion stage 2, 4, 6 or 8
read/write heads per BL ident interface can be
connected.
For use in cyclic systems where acyclic data
transmissions is not possible (e.g. Profibus® DPV0).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL67-2RFID-C
M6827238
Number of Channels
Nominal voltage Vi
Rated current from field supply
Rated current from module bus
Power loss, typical
2
24 VDC
<100 mA
<30 mA
<1 W
Inputs/Outputs
Transmission rate
Cable length
115.2 kbps
50 m
Electrical isolation of electronics and field level via opto couplers
Simultaneity factor
1
Sensor supply
0.5 A per channel, short-circuit proof
Number of Diagnostic Bytes
Number of parameter bytes
Number of input bytes
Number of output bytes
4
8
4
4
Dimensions (L x W x H)
Operating temperature
Storage temperature
Relative humidity
Vibration test
91 x 32 x 59 mm
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95% (internal), Level RH-2, no condensation (at 45°C (113°F) storage)
Acc. to EN 61131
Pinout
Mating Cordset:
RK 4.5T-*-RS 4.5T/S2501
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
76
TURCK
RFID Products
RFID System - Interface for PROFIBUS®-DP (DPV1) - IP 20
• Interface Between BL ident System and PROFIBUS-DP (DPV0)
• Connection of Up to 8 BL ident Read/Write Heads
• 2 Decimal Rotating Coding Switches
• LEDs for Display of Power Supply, Collective and Bus Errors as Well
as Status and Diagnostics
• 9-Pin Sub-D Socket
• Connection of Read/Write Heads Using BL ident Connecting Cable
• Compatible with Siemens S7-300 Processors*
Housing
Part Number
BL20-GW-DPV1
ID Number
Function Principle
M6827234
The BL ident interface serves for connection of the BL
ident system to the higher priority fieldbus. 2, 4, 6 or 8
read/write heads can be connected, depending on the
type of unit. Data exchange is accomplished in parallel
with the individual read/write heads.
* Other processors may be supported. Contact factory for assitance or check www.turck.com.
See Fieldbus I/O and Media catalog for specific gateway specifications.
77
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-GW-DPV1
M6827234
Power Supply
Field power supply
Permissible range
Rated current from module bus
24 VDC / 5 VDC
24 VDC
Acc. EN 61131-2
430 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Fieldbus addressing
Service interface
Fieldbus connection
Power supply connection
Fieldbus terminator
1 to 99
2 rotary switches
PS/2 socket for I/O-ASSISTANT
1 x SUB-D socket
Screw connection
External
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
Cage clamp or screw terminals
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidty
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
Field Power Supply / System Power Supply
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
78
TURCK
RFID Products
RFID System - Interface for DeviceNet™ - IP 20
• Interface Between BL ident System and DeviceNet
• Connection of Up to 8 BL ident Read/Write Heads
• 2 Decimal Rotating Coding Switches
• LEDs for Display of Power Supply, Collective and Bus Errors as Well
as Status and Diagnostics
• Connection to DeviceNet via Open Style Connector
• Connection of Read/Write Heads Using BL ident Connecting Cable
• Compatible with Allen-Bradley Controllogix Processors*
Housing
Part Number
ID Number
Function Principle
BL20-GWBR-DN
M6827168
The BL ident interface serves for connection
of the BL ident system to the higher priority
fieldbus. 2, 4, 6 or 8 read/write heads can
be connected, depending on the type of unit.
Data exchange is accomplished in parallel with
the individual read/write heads.
* Other processors supported. Contact factory for assitance or check www.turck.com
See Fieldbus I/O and Media catalog for specific gateway specifications.
79
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-GWBR-DN
M6827168
Power Supply
Field power supply
Permissible range
Rated current from module bus
24 VDC / 5 VDC
24 VDC
Acc. EN 61131-2
430 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Fieldbus addressing
Service interface
Fieldbus connection
Power supply connection
Fieldbus terminator
1 to 99
2 rotary switches
PS/2 socket for I/O-ASSISTANT
1 x SUB-D socket
Screw connection
External
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
Cage clamp or screw terminals
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidty
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
Field Power Supply / System Power Supply
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
80
TURCK
RFID Products
RFID System - Interface for Modbus-TCP - IP 20
• Connection of Up to 8 BL ident Read/Write Heads
• Programmable According to IEC 61131-3 with CoDeSys
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• RJ45 Connector for Fieldbus Connection
• Connection of Read/Write Heads Using BL ident Connecting Cable
Housing
Part Number
BL20-PG-EN
ID Number
Function Principle
M6827249
The BL ident programmable interface
serves for connection of the BL ident
system to the higher priority fieldbus. By
using a programmable gateway, network
and PLC usage will decrease. 2, 4, 6 or
8 read/write heads can be connected,
depending on the type of unit. Data
exchange is accomplished in parallel with
the individual read/write heads.
See Fieldbus I/O and Media catalog for specific gateway specifications.
Field Power Supply / System Power Supply
81
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-PG-EN
M6827249
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 socket for I/O-ASSISTANT
RJ45
Screw connection
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
Cage clamp or screw terminals
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
PLC Data
Programming
Released for CoDoSys Version
Programming languages
Application tasks
Number of POUs
Programming interface
Cycle time
Real time clock
Program memory
Data memory
Input data
Output data
Non-volatile memory
CoDeSys V2.3
V 2.3.5.8
IEC 61131-3 (IL, LD, FBD, SFC, ST)
1
1024
RS232 interface, Ethernet
RISC
32 bit
< 1 ms for 1000 IL commands (without I/O cycle)
Yes
512 kByte
512 kByte
4 kByte
4 kByte
16 kByte
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
82
TURCK
RFID Products
RFID System - Interface for Ethernet/IP IP 20
• Connection of Up to 8 BL ident Read/Write Heads
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• RJ45 Connector for Fieldbus Connection
• Connection of Read/Write Heads Using BL ident Connecting Cable
• Compatible with Allen-Bradley Controllogix Processor*
Housing
Part Number
ID Number
Function Principle
BL20-GW-EN-IP
M6827247
The BL ident interface serves for
connection of the BL ident system to
the higher priority fieldbus. 2, 4, 6 or
8 read/write heads can be connected,
depending on the type of unit. Data
exchange is accomplished in parallel
with the individual read/write heads.
* Other processors may be supported. Contact factory for assistance or check www.turck.com.
See Fieldbus I/O and Media catalog for specific gateway specifications.
Field Power Supply / System Power Supply
83
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-GW-EN-IP
M6827247
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 socket for I/O-ASSISTANT
RJ45
Screw connection
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
Cage clamp or screw terminals
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
PLC Data
Programming
Released for CoDoSys Version
Programming languages
Application tasks
Number of POUs
Programming interface
Cycle time
Real time clock
Program memory
Data memory
Input data
Output data
Non-volatile memory
CoDeSys V2.3
V 2.3.5.8
IEC 61131-3 (IL, LD, FBD, SFC, ST)
1
1024
RS232 interface, Ethernet
RISC
32 bit
< 1 ms for 1000 IL commands (without I/O cycle)
Yes
512 kByte
512 kByte
4 kByte
4 kByte
16 kByte
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
84
TURCK
RFID Products
RFID System - Interface for Ethernet/IP IP 20
• Connection of Up to 8 BL ident Read/Write Heads
• Programmable According to IEC 61131-3 with CoDeSys
• LEDs for Display of Power Supply, Collective and Bus Errors as Well as Status
and Diagnostics
• RJ45 Connector for Fieldbus Connection
• Connection of Read/Write Heads Using BL ident Connecting Cable
Housing
Part Number
BL20-PG-EN-IP
ID Number
Function Principle
M6827248
The BL ident programmable interface
serves for connection of the BL ident
system to the higher priority fieldbus. By
using a programmable gateway, network
and PLC usage will decrease. 2, 4, 6 or
8 read/write heads can be connected,
depending on the type of unit. Data
exchange is accomplished in parallel
with the individual read/write heads.
See Fieldbus I/O and Media catalog for specific gateway specifications.
Field Power Supply / System Power Supply
85
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-PG-EN-IP
M6827248
Power Supply
Permissible range
Rated current from module bus
24 VDC
18 to 30 VDC
650 mA + 30 mA/plate (2 channel)
Fieldbus Address Range
Service interface
Fieldbus connection
Power supply connection
Rotary switches, BOOTP, DHCP, I/O-ASSISTANT
PS/2 socket for I/O-ASSISTANT
RJ45
Screw connection
Inputs/Outputs
Potential separation
Read/write head connection
Read/write head power supply
Via optocoupler
Cage clamp or screw terminals
0.5 A/channel, short-circuit protected
Simultaneity Factor
1
Operating Temperature
Storage temperature
Relative humidity
Vibration test
Shock test
Toppling and upsetting
Electromagnetic compatibility
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95 % (internal), level RH-2, no condensation (at 45°C (113°F) storage)
Acc. EN 61131
Acc. IEC 68-2-27
Acc. IEC 68-2-31 and free fall according to IEC 68-2-32
Acc. EN 61131-2
PLC Data
Programming
Released for CoDoSys Version
Programming languages
Application tasks
Number of POUs
Programming interface
Cycle time
Real time clock
Program memory
Data memory
Input data
Output data
Non-volatile memory
CoDeSys V2.3
V 2.3.5.8
IEC 61131-3 (IL, LD, FBD, SFC, ST)
1
1024
RS232 interface, Ethernet
RISC
32 bit
< 1 ms for 1000 IL commands (without I/O cycle)
Yes
512 kByte
512 kByte
4 kByte
4 kByte
16 kByte
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
86
TURCK
RFID Products
RFID System - Standard RFID Module
• For Use With the Gateway BL20-GW-DPV1 in DPV0 Mode
• Acyclical exchange of data
• Degree of Protection IP 20
• LEDs for Display of Status and Diagnostics
• Electronics galvanically isolated from the field level via opto couplers
• connection of 2 BL ident read/write heads
Housing
Part Number
BL20-2RFID-A
87
ID Number
Function Principle
M6827233
The BL ident interfaces can be fitted with
additional read/write head connections using
RFID extension modules. The extension
modules are plugged onto purely passive base
modules. The field devices are connected via
the base modules.
Depending on the expansion stage 2, 4, 6 or
8 read/write heads per BL ident interface can
be connected.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-2RFID-A
M6827233
Number of Channels
Nominal voltage Vi
Rated current from field supply
Rated current from module bus
Power loss, typical
2
24 VDC
<100 mA
<30 mA
<1 W
Inputs/Outputs
Transmission rate
Cable length
115.2 kbps
50 m
Electrical isolation of electronics and field level via opto couplers
Simultaneity factor
1
Sensor supply
0.5 A per channel, short-circuit proof
Number of diagnostic bytes
Number of parameter bytes
Number of input bytes
Number of output bytes
4
8
4
4
Dimensions (L x W x H)
Operating temperature
Storage temperature
Relative humidity
Vibration test
91 x 32 x 59 mm
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95% (internal), Level RH-2, no condensation (at 45°C (113°F) storage)
acc. to EN 61131
Wiring Diagram
Mating Cordset:
RK 4.5T-*/S2501
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
88
TURCK
RFID Products
RFID System - RFID Module for DPV0 PLC's
• For Use With the Gateway BL20-GW-DPV1 in DPV0 Mode
• Cyclical exchange of data
• Degree of Protection IP 20
• LEDs for Display of Status and Diagnostics
• Electronics galvanically isolated from the field level via opto couplers
• connection of 2 BL ident read/write heads
• Designed for use in Profibus DPV0 Systems
Housing
89
Part Number
ID Number
Function Principle
BL20-2RFID-C
M6827225
The BL ident interfaces can be fitted with
additional read/write head connections using
RFID extension modules. The extension
modules are plugged onto purely passive base
modules. The field devices are connected via
the base modules.
Depending on the expansion stage 2, 4, 6 or
8 read/write heads per BL ident interface can
be connected.
For use in cyclic systems where acyclic data
transmissions is not possible (e.g. Profibus®
DPV0).
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Part Number
ID Number
BL20-2RFID-C
M6827225
Number of Channels
Nominal voltage Vi
Rated current from field supply
Rated current from module bus
Power loss, typical
2
24 VDC
<100 mA
<30 mA
<1 W
Inputs/Outputs
Transmission rate
Cable length
115.2 kbps
50 m
Electrical isolation of electronics and field level via opto couplers
Simultaneity factor
1
Sensor supply
0.5 A per channel, short-circuit proof
Number of diagnostic bytes
Number of parameter bytes
Number of input bytes
Number of output bytes
4
8
4
4
Dimensions (L x W x H)
Operating temperature
Storage temperature
Relative humidity
Vibration test
91 x 32 x 59 mm
0 to +55°C (32 to +131°F)
-25 to +85°C (-13 to +185°F)
5 to 95% (internal), Level RH-2, no condensation (at 45°C (113°F) storage)
acc. to EN 61131
Wiring Diagram
Mating Cordset:
RK 4.5T-*/S2501
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
90
TURCK
RFID Products
Dimensions
TB-M18-H1147
TN-M18-H1147
18 mm - Embeddable
18 mm - Nonembeddable
TB-M30-H1147
TN-M30-H1147
30 mm - Embeddable
30 mm - Nonembeddable
TN-CK40-H1147
40 mm - Nonembeddable
91
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
Dimensions
TN-Q80-H1147
80 mm - Nonembeddable
TN-S32XL-H1147
32 mm - Nonembeddable
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
92
TURCK
RFID Product Index
BL20-2RFID-A
BL20-2RFID-C
BL20-GW-DPV1
BL20-GW-EN-IP
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
87
89
77
83
PD-IDENT-CB
PD-IDENT-DS
PD-IDENT-PF
PD-IDENT-RB
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
22
22
22
22
BL20-GWBR-DN
BL20-PG-EN
.
BL20-PG-EN-IP
BL20-S4T-SBBS
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
79
81
85
17
PD-IDENT-RS .
PD-IDENT-WLAN
QM-18 . . . .
QM-30 . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
22
22
23
24
BL67-2RFID-A
.
BL67-2RFID-C
.
BL67-B-2M12 . .
BL67-GW-DN
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
73
75
18
63
RK
RK
RK
RK
4.5T-10-RS 4.5T/S2501
. .
4.5T-10/S2501
. . . . . .
4.5T-2-RS 4.5T/S2501 . . .
4.5T-2/S2051 . . . . . . .
.
.
.
.
20
20
20
20
BL67-GW-DPV1
BL67-GW-EN-IP
BL67-GW-EN-PN
BL67-PG-DP
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
59
69
67
61
RK 4.5T-5-RS 4.5T/S2501
RK 4.5T-5/S2501 . . . .
SG40/2
. . . . . . . .
T-CK40-D-FC . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
20
20
26
25
BL67-PG-EN
.
BL67-PG-EN-IP
BS18
. . . .
BSN18 . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
65
71
23
23
T-CK40-T-FC .
TB-M18-H1147
TB-M30-H1147
TN-CK40-H1147
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
25
45
49
53
BST-18B
BST-18N
BST-30B
BST-30N
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
23
24
24
TN-M18-H1147
. . . .
TN-M30-H1147
. . . .
TN-Q80-H1147
. . . .
TN-S32XL-H1147
. . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
47
51
55
57
BST-BS
. . . . . . .
BST-UH
. . . . . . .
BST-UV
. . . . . . .
CABLE RFID/S2501-150M
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
26
24
24
20
TW-R16-B128
TW-R20-B128
TW-R20-K2 .
TW-R30-B128
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
27
29
35
31
CABLE
CABLE
CABLE
CABLE
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
20
20
20
20
TW-R30-K2 . . . .
TW-R50-90-HT-B128
TW-R50-90-HT-K2 .
TW-R50-B128 . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
37
41
43
33
39
20
20
20
.
.
.
.
.
.
.
.
.
.
.
.
RFID/S2501-225M
RFID/S2501-300M
RFID/S2501-30M
RFID/S2501-75M
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
CAP-18N-PTFE
. .
CAP 18-PTFE . . .
CAP 30-PTFE . . .
CAP 30N-PTFE
. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
23
24
24
TW-R50-K2 . . . . . . . . . . .
WK 4.5T-10-RS 4.5T/S2501
. . .
WK 4.5T-10/S2501
. . . . . . .
WK 4.5T-2-RS 4.5T/S2501 . . . .
DS-R30
. . . . .
DS-R50
. . . . .
JS 025/037
. . .
MF-CK40-1S
. . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
26
26
26
25
WK 4.5T-2/S2051 . . . . . . . . 20
WK 4.5T-5-RS 4.5T/S2501 . . . . 20
WK 4.5T-5/S2501 . . . . . . . . 20
MF-CK40-2S
MF-CK40-3S
PD-IDENT
.
PD-IDENT-BC
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
25
25
22
22
93
.
.
.
.
.
.
.
.
.
.
.
.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
TURCK Inc. sells its products through Authorized Distributors. These distributors provide our
customers with technical support, service and local stock. TURCK distributors are located
nationwide - including all major metropolitan marketing areas.
For Application Assistance or for the location of your nearest TURCK distributor, call:
1-800-544-7769
Specifications in this manual are subject to change without notice. TURCK also reserves
the right to make modifications and makes no guarantee of the accuracy of the information
contained herein.
Literature and Media questions or concerns?
Contact Marketing Communications TURCK USA - [email protected]
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
94
TURCK
RFID Products
RISK OF LOSS
Delivery of the equipment to a common carrier shall constitute delivery to the Purchaser and the risk of loss shall transfer at that time to
Purchaser. Should delivery be delayed due to an act or omission on the part of the Purchaser, risk of loss shall transfer to the Purchaser upon
notification by TURCK Inc. that the order is complete and ready for shipment.
WARRANTIES
TURCK INC. (hereinafter “TURCK”) offers five (5) WARRANTIES to cover all products sold. They are as follows:
1) The 12-MONTH WARRANTY is available for the products listed - generally those not covered by LIFETIME, 5-YEAR, 24-MONTH or
18-MONTH warranty. No registration required.
2) The 18-MONTH WARRANTY is available for the products listed - generally those not covered by LIFETIME or 5-YEAR WARRANTY.
No registration is required.
3) The 24-MONTH WARRANTY is available for the products listed - generally those not covered by LIFETIME, 5-YEAR or 18-MONTH.
No registration is required.
4) The 5-YEAR WARRANTY is available generally for the products listed. No registration is required.
5) A LIFETIME WARRANTY is available for the products listed. It becomes effective when the accompanying TURCK LIFETIME
WARRANTY REGISTRATION is completed and returned to TURCK.
GENERAL TERMS AND CONDITIONS FOR ALL WARRANTIES
•
•
•
•
•
12-MONTH STANDARD WARRANTY
18-MONTH STANDARD WARRANTY
24-MONTH STANDARD WARRANTY
5-YEAR WARRANTY
LIFETIME WARRANTY
TURCK warrants the Products covered by the respective WARRANTY AGREEMENTS to be free from defects in material and workmanship
under normal and proper usage for the respective time periods listed above from the date of shipment from TURCK. In addition, certain
specific terms apply to the various WARRANTIES.
THESE EXPRESS WARRANTIES ARE IN LIEU OF AND EXCLUDE ALL OTHER REPRESENTATIONS MADE - BOTH EXPRESSED AND
IMPLIED. THERE ARE NO WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR PRODUCTS
COVERED BY THESE TERMS AND CONDITIONS.
TURCK warrants that the goods sold are as described, but no promise, description, affirmation of fact, sample model or representation,
oral or written shall be part of an order, unless set forth in these terms and conditions, or are in writing and signed by an authorized
representative of TURCK. These WARRANTIES do not apply to any Product which has been subject to misuse, negligence, or accident - or
to any Product which has been modified or repaired, improperly installed, altered, or disassembled -except according to TURCK’s written
instructions.
These WARRANTIES are subject to the following conditions:
1) These WARRANTIES are limited to the electronic and mechanical performance only, as expressly detailed in the Product
specifications and NOT to cosmetic performance.
2) These WARRANTIES shall not apply to any cables attached to, or integrated with the Product. However, the 18-MONTH WARRANTY
shall apply to cables sold separately by TURCK.
3) These WARRANTIES shall not apply to any Products which are stored, or utilized, in harsh environmental or electrical conditions
outside TURCK’s written specifications.
4) The WARRANTIES are applicable only to Products shipped from TURCK subsequent to January 1, 1988.
ADDITIONAL SPECIFIC TERMS FOR (12-MONTH STANDARD WARRANTY) for Linear Displacement Transducers and RFID products.
(18-MONTH STANDARD WARRANTY) FOR ULTRASONIC SENSORS, CABLES AND ALL NON-SENSING PRODUCTS SOLD BY
TURCK INC. INCLUDING MULTI-SAFE, MULTI-MODUL, MULTI-CART AND RELATED AMPLIFIER PRODUCTS, RELAYS AND
TIMERS.
(24-MONTH STANDARD WARRANTY) FOR ENCODERS.
5-YEAR WARRANTY FOR INDUCTIVE AND CAPACITIVE PROXIMITY SENSORS: The periods covered for the above WARRANTIES
and Products shall be 12 MONTHS, 18-MONTHS, 24-MONTHS and 5-YEARS, respectively, from the date of shipment from TURCK.
95
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Industrial
Automation
ADDITIONAL SPECIFIC TERMS FOR - (continued)
LIFETIME WARRANTY (OPTIONAL - REGISTRATION REQUIRED) FOR INDUCTIVE, INDUCTIVE MAGNET OPERATED AND CAPACITIVE
PROXIMITY SENSORS SOLD TO THE ORIGINAL PURCHASER FOR THE LIFETIME OF THE ORIGINAL APPLICATION.
The following terms apply to the LIFETIME WARRANTY in addition to the General Terms:
1) This WARRANTY shall be effective only when the LIFETIME WARRANTY
REGISTRATION has been completed, signed by
the End User and an authorized TURCK Representative or Distributor and has been received by TURCK no later than six (6) months
after installation in the End User’s Plant, or two (2) years from the date product was shipped from TURCK, whichever is sooner.
2) This warranty is available only to TURCK’s authorized Representatives, Distributors and to the Original User. (The term “Original User”
means that person, firm, or corporation which first uses the Product on a continuous basis in connection with the operation of a
production line, piece of machinery, equipment, or similar device.) In the event the ownership of the product is transferred to a
person, firm or corporation other than the Original User, this WARRANTY shall terminate.
3) This WARRANTY is applicable only to the Original Application. In the event the machinery, equipment, or production line to which
the Product is connected, or on which it is installed, is substituted, changed, moved or replaced, the WARRANTY shall terminate.
4) This WARRANTY shall be valid only if the Product was purchased by the Original User from TURCK, or from an authorized TURCK
Distributor, or was an integral part of a piece of machinery and equipment obtained by the Original user from an Original Equipment
Manufacturer, which itself, was purchased directly from TURCK or from an authorized Distributor.
PURCHASER’S REMEDIES
This Remedy shall apply to all WARRANTIES. If a TURCK Distributor desires to make a WARRANTY Claim, the Distributor shall, if requested
by TURCK, ship the Product to TURCK’s factory in Minneapolis, Minnesota, postage or freight prepaid. If the User desires to make a
WARRANTY Claim, they shall notify the authorized TURCK Distributor from whom it was purchased or, if such Distributor is unknown, shall
notify TURCK. TURCK shall, at its option, take any of the following two courses of action for any products which TURCK determines are
defective in materials or workmanship.
1) Repair or replace the Product and ship the Product to the Original Purchaser or to the authorized TURCK Distributor, postage or
freight prepaid; or
2) Repay to the Original Purchaser that price paid by the Original Purchaser; provided that if the claim is made under the LIFETIME
WARRANTY, and such Product is not then being manufactured by TURCK, then the amount to be repaid by TURCK to the Original
Purchaser shall be reduced according to the following schedule:
Number of Years Since Date
of Purchase by Original Purchaser
10
15
20
More than 20
Percent of Original Purchase
Price To Be Paid by TURCK
50%
25%
10%
5%
PURCHASER’S REMEDIES SHALL BE LIMITED EXCLUSIVELY TO THE RIGHT OF REPLACEMENT, REPAIR OR REPAYMENT AS PROVIDED
AND DOES NOT INCLUDE ANY LABOR COST OR REPLACEMENT AT ORIGINAL PURCHASER’S SITE. TURCK SHALL NOT BE LIABLE
FOR ANY CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF ANY WARRANTY, EXPRESSED OR IMPLIED, APPLICABLE
TO THE PRODUCT, INCLUDING WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM PROPERTY DAMAGE, PERSONAL INJURY
OR BUSINESS INTERRUPTION.
CONSIDER SAFETY AND PROTECTION PRECAUTIONS
TURCK takes great care to design and build reliable and dependable products, however, some products can fail eventually. You must
take precautions to design your equipment to prevent property damage and personal injury in the unlikely event of failure. As a matter of
policy, TURCK does NOT recommend the installation of electronic controls as the sole device FOR THE PROTECTION OF PERSONNEL in
connection with power driven presses, brakes, shears and similar equipment and, therefore, the customer should build in redundancy or dual
control using approved safety devices for these applications.
GOVERNING LAW
The sale and purchase of Products covered hereby and all terms and conditions hereof shall be governed by the law of the State of Minnesota.
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
96
TURCK
RFID Products
BLident Project Checklist
Customer: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Project: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Author: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data Carrier (TAG):
Size/format:
R16 F
R20 F
R30 F
R50 F
Memory capacity/Byte:
64 F
128 F
2k F
Other F
Other F
Type of memory:
EEPROM F
Mounting:
Distance TAG-TAG . . . . . . . . . . . . . . . . . . . . . . .
FRAM F
Temperature range: . . . . . . . . . . . . . . . . . .
Degree of protection: . . . . . . . . . . . . . . . .
Read-Write Head (RWH):
M30 F
CK40 F
Q80 F
S32XL F
Size/format:
M18 F
Mounting:
Distance RWH-RWH . . . . . . . . . . . . . . . . . . . . .
Other F
Temperature range: . . . . . . . . . . . . . . . . . .
Degree of protection: . . . . . . . . . . . . . . . .
TAG and RWH:
Reading "on the fly" F
Writing "on the fly" F
Read-Write distance: . . . . . . . . . . . . . . . . . Application speed: . . . . . . . .Amount of data: . . . . . . . . . . Byte
System Configuration:
Gateway type:
BL20 F
BL67 F
Standard F
Programmable F
Qty
Bus type:
DeviceNet F
Ethernet IP F
Modbus/TCP F
Profibus DPV0 F
Profibus DPV1 F Profinet F
BL20 F
BL67 F
Qty
Dual channel interface module:
Siemens S7-300 F
Control system:
AB Controllogix F
AB SLC500 F
AB PLC5 F
Other F
Which support is requested by the customer?
Presales:
Yes F
No F
Technical training etc. by Product Marketing
Yes F
No F
Customer is willing to pay?*
Yes F
No F
System integrator
Yes F
No F
Visit with system integrator
Yes F
No F
Hardware installation
Yes F
No F
PLC
Yes F
No F
PC
Yes F
No F
Or
Integration in to ERP
Yes F
No F
Which?
Product presentation etc. by Product Marketing
Further Activities:
Or
Software Programming:
Comments:
* See valid business terms covering our service price list for 2007.
See www.turck.com for printable version.
97
TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
THE FIRST REMOTE
I/O SYSTEM THAT THINKS
OUTSIDE THE BOX
TURCK BL67
Remote I/O.
No enclosure
required.
Beyond the walls of
conventional thinking.
Electronic
Modules
„ Digital & Analog
„ Temperature
„ RS232/485
„ Counter
„ SSI
Network
Protocols
Connectivity
Options
„ M12 eurofast ®
„ DeviceNet™
®
„ PROFIBUS -DP „ 7⁄ 8 -16 minifast ®
„ Ethernet
„ M8 picofast ®
™
„ CANopen
TURCK BL67 remote I/O systems
combine all the flexibility of an in-cabinet
PLC—plus compact modularity, IP67
rated rugged construction and efficient
connectorization. Configure your BL67
just the way you need it with up to
32 electronic modules and up to 64
analog or 256 digital I/O points. The
fully connectorized BL67 mounts right
on machinery without an enclosure
to reduce installation expense and
eliminate the hassles of hand wiring.
The included TURCK I/O assistant
software provides parameter set-up,
documentation, commissioning, and
diagnostic function for online or offline
usage. Best of all, the software is free.
Call us with your next application:
1-800-544-7769
email: [email protected]
www.turck.com
©2006 TURCK, Inc.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
Access to all TURCK catalogs, press releases,
white papers and tutorials
Complete category listing
of TURCK products
Search for products
by part number, ID
number or key word
Access to CAD,
wiring and
pinout diagrams
TURCK’s USA website is your most
complete and up-to-date source for product
documentation, CAD files and more.
Search results produce downloadable
documentation or request for quote (RFQ).
Additional product information or CAD files
are easily requested and promptly filled.
Option to
e-mail pages
Download or e-mail
files, request for quote
Contact a
TURCK representative
Visit our site for new product releases,
approvals, white papers, application
support and more.
www.turck.com
TURCK USA
TURCK Mexico
TURCK Canada
TURCK Inc.
3000 Campus Drive
Minneapolis, MN 55441
Phone: (763) 553-7300
Fax:
(763) 553-0708
Application Support:
1-800-544-7769
TURCK MEXICO S. DE R.L. DE C.V.
Carr Saltillo-Zacatecas km 4.5 s/n
Parque Industrial “La Angostura”
Saltillo, COAH. C.P. 25070
MEXICO
Phone: +52 (844) 411-6647/46
Fax:
+52 (844) 482-6926
Toll Free: 01-800-01-88725 (Mexico only)
E-mail: [email protected]
CHARTWELL
ELECTRONICS, INC.
140 Duffield Drive
Markham, Ontario
Canada, L6G 1B5
Phone: (905) 513-7100
Fax:
(905) 513-7101
Toll Free: 1-877-513-7769
TURCK
World Headquarters
Hans TURCK GmbH & Co. KG
Witzlebenstrasse 7
D-45472 Muelheim der Ruhr
Federal Republic Of Germany
Phone: (+49) 208-49 52-0
Fax:
(+49) 208-49 52 264
B3005
Printed in USA
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123
www.barr-thorp.com
6/07
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement