ART-2 3 Adjustable Recycling Timer

ART-2 3 Adjustable Recycling Timer
ART-2 & 3 Adjustable Recycling Timer
CAP offers a full range of equipment for the growing enthusiasts. The ART
series of recycling timers can control almost any application requiring a load
to be turned on and off at precise intervals. There’s nothing to program… just
set the two dials, plug in the device to be controlled, and plug in the timer.
OVERVIEW
•
The ART Timer simply plugs into existing 15 amp, 120 volt outlet.
•
The ART Timer can control up to 15 amps @ 120 volts.
•
The ART-2 has an on time = 30 seconds to 20 minutes and an off time of 3 minutes to 120
minutes.
•
The ART-3 has an on time = 30 seconds to 20 minutes and an off time of 12 minutes to 480
minutes.
CONNECTIONS & OPERATION
There are certain steps which should be taken to ensure a successful installation of your
ART Timer.
1) Determine the desired location for the ART Timer. The cord from the device that you are
planning to control must be able to reach the outlet on the front of the ART timer.
2) Adjust the ART Timer to the settings that you want by turning the ON and OFF knobs to the
desired timing schedule.
3)
Plug in the ART Timer into a wall outlet and the ON time should start immediately.
* NOTE: To set a new timing schedule, you must set the knobs and unplug the timer from the wall and then plug it back in.
4)
Plug the exhaust fan or air conditioner into one of the two receptacles. (Maximum 15 amps @ 120 volts)
PRECAUTIONS
Do not expose the ART to water. Electrical shock may occur.
Do not not exceed the 15 amp rating!
WARRANTY
The ART TImer is warranted against defects in workmanship and parts for Three Years.
SPECIFICATIONS
Main power voltage:
Temperature control range:
ART-2 Timing ON:
ART-3 Timing ON:
120 volts
50-115° F
30 seconds - 20 Minutes ON
30 seconds - 20 Minuest ON
Maximum amperage:
Temperature operating range:
ART-2 Timing OFF:
ART-3 Timing OFF:
15 amps
32-120° F
3-120 Minutes OFF
12-480 Minutes OFF
Published by R & M Supply, Inc.
Copyright 2002-2005 All Rights Reserved
R & M Supply, Inc. and their retailers and distributors are not responsible for any damage or injuries, consequential or otherwise arising
from the use of this product. The purchaser assumes all responsibility for the use and proper installation of this device.
www.capcontrollers.com