KA675/KA680/KA690 CPU System Maintenance Order Number EK–454AA–MG–001

KA675/KA680/KA690 CPU System Maintenance Order Number EK–454AA–MG–001
run e
KA675/KA680/KA690 CPU
System Maintenance
Order Number EK–454AA–MG–001
***********************************************************
Information for Reviewers
•
Final Draft, 17 April 92
•
This draft contains new material, marked by
changebars, covering the KA675 and KA690,
as well as a section on Kernal support for
VAXsimPLUS.
•
Please return your comments no later than
Wednesday, April 29.
***********************************************************
Digital Equipment Corporation
Maynard, Massachusetts
First Printing, May 1992
The information in this document is subject to change without notice and should not be
construed as a commitment by Digital Equipment Corporation.
Digital Equipment Corporation assumes no responsibility for any errors that may appear in
this document.
The software, if any, described in this document is furnished under a license and may be used
or copied only in accordance with the terms of such license. No responsibility is assumed
for the use or reliability of software or equipment that is not supplied by Digital Equipment
Corporation or its affiliated companies.
Restricted Rights: Use, duplication, or disclosure by the U.S. Government is subject to
restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer
Software clause at DFARS 252.227–7013.
Copyright © Digital Equipment Corporation, 1991. All Rights Reserved.
The Reader’s Comments form at the end of this document requests your critical evaluation to
assist in preparing future documentation.
The following are trademarks of Digital Equipment Corporation: CompacTape, CX, DDCMP,
DEC, DECconnect, DECdirect, DECnet, DECscan, DECserver, DECUS, DECwindows,
DELNI, DEMPR, DESQA, DESTA, DSRVB, DSSI, IVAX, KDA, KLESI, MicroVAX, MSCP,
Q–bus, Q22–bus, RA, RQDX, RRD40, SDI, ThinWire, TK, TMSCP, TQK50, TQK70, TSV05,
TU, ULTRIX, UNIBUS, VAX, VAX 4000, VAX DOCUMENT, VAXcluster, VAXELN, VAXlab,
VAXserver, VAXsimPLUS, VMS, VT, and the DIGITAL logo.
FCC NOTICE: The equipment described in this manual generates, uses, and may emit radio
frequency energy. The equipment has been type tested and found to comply with the limits for
a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed
to provide reasonable protection against such radio frequency interference when operated in
a commercial environment. Operation of this equipment in a residential area may cause
interference, in which case the user at his own expense may be required to take measures to
correct the interference.
ML–S1678
This document was prepared using VAX DOCUMENT, Version 2.0.
Contents
xiv
Preface
Chapter 1 System Maintenance Strategy
1.1
1.2
1.3
1.4
Service Delivery Methodology . . . .
Product Service Tools and Utilities
Information Services . . . . . . . . . . .
Field Feedback . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1–1
1–2
1–4
1–6
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2–1
2–5
2–6
2–6
2–12
2–14
2–15
2–17
CPU and Memory Module Order . . . . . . . . . . .
Installing Add-On MS690 Memory Modules
General Module Order for Q-Bus Options . . . .
Recommended Module Order of Q–bus Options
Mass Storage Options (Internal) . . . . . . . . . . .
System Expansion . . . . . . . . . . . . . . . . . . . . . .
Mass Storage Expanders . . . . . . . . . . . . . . .
Q-Bus Expanders . . . . . . . . . . . . . . . . . . . . .
Control Power Bus for Expanders . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3–1
3–2
3–4
3–5
3–6
3–8
3–8
3–8
3–9
Chapter 2 CPU System Overview
2.1
CPU Module Features . . . . . . .
2.2
MS690 Memory Modules . . . . .
2.3
BA440 Enclosure Components .
2.3.1
H3604 Console Module . . . . .
2.3.2
System Control Panel (SCP)
2.3.3
BA440 Backplane . . . . . . . . .
2.3.4
Power Supply . . . . . . . . . . . .
2.3.5
System Airflow . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Chapter 3 System Setup and Configuration
3.1
3.1.1
3.2
3.3
3.4
3.5
3.5.1
3.5.2
3.5.3
iii
3.5.4
Adding Options to the System Enclosure . . . . . . . . . . . . . .
3.6
DSSI VAXclusters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1
DSSI VAXcluster Configuration Rules . . . . . . . . . . . . . . . .
3.7
Firmware Commands and Utilities Used in System
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.1
Examining System Configuration . . . . . . . . . . . . . . . . . . . .
3.7.2
Using the CONFIGURE Command to Determine CSR
Addresses for Q-Bus Modules . . . . . . . . . . . . . . . . . . . . . . .
3.7.3
Setting and Examining Parameters for DSSI Devices . . . .
3.7.3.1
DSSI Device Parameters . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3.2
How VMS Uses the DSSI Device Parameters . . . . . . . .
3.7.3.3
Entering the DUP Driver Utility from Console Mode . .
3.7.3.4
Entering the DUP Driver Utility from VMS . . . . . . . . .
3.7.3.5
Setting Allocation Class . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3.6
Setting Unit Number . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3.7
Setting Node Name . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3.8
Setting System ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3.9
Exiting the DUP Driver Utility . . . . . . . . . . . . . . . . . . .
3.7.4
Write-Protecting an RF35 ISE . . . . . . . . . . . . . . . . . . . . . .
3.7.4.1
Software Write-Protect for RF-Series ISEs . . . . . . . . . . .
3.7.4.2
Hardware Write-Protect For RF35 ISEs . . . . . . . . . . . . .
3.7.5
Setting System Parameters: Boot Defaults, Bootflags, Halt
and Restart Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.5.1
Setting the Boot Default . . . . . . . . . . . . . . . . . . . . . . . .
3.7.5.2
Setting Boot Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.5.3
Setting the Halt Action . . . . . . . . . . . . . . . . . . . . . . . . .
3–9
3–13
3–15
3–18
3–18
3–21
3–23
3–23
3–24
3–30
3–31
3–32
3–33
3–36
3–36
3–37
3–39
3–39
3–40
3–43
3–43
3–45
3–46
Chapter 4 System Initialization and Acceptance Testing
(Normal Operation)
4.1
Basic Initialization Flow . . . . . . . . . . . . . . .
4.2
Power-On Self-Tests (POST) . . . . . . . . . . . . .
4.2.1
Power-Up Tests for Kernel . . . . . . . . . . . .
4.2.2
Power-Up Tests for Q-Bus Options . . . . . .
4.2.3
Power-Up Tests for Mass Storage Devices
4.3
CPU ROM-Based Diagnostics . . . . . . . . . . .
4.3.1
Diagnostic Tests . . . . . . . . . . . . . . . . . . . .
iv
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4–1
4–4
4–4
4–7
4–8
4–8
4–9
4.3.2
Scripts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4
Basic Acceptance Test Procedure . . . . . . . . . . . . . . . . . .
4.5
Machine State on Power-up . . . . . . . . . . . . . . . . . . . . . .
4.6
Main memory layout and state . . . . . . . . . . . . . . . . . . .
4.6.1
Reserved Main Memory . . . . . . . . . . . . . . . . . . . . . . .
4.6.1.1
PFN Bitmap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.1.2
Scatter/Gather map . . . . . . . . . . . . . . . . . . . . . . . .
4.6.1.3
Firmware "Scratch Memory" . . . . . . . . . . . . . . . . .
4.6.2
Contents of main memory . . . . . . . . . . . . . . . . . . . . .
4.6.3
Memory controller Registers . . . . . . . . . . . . . . . . . . .
4.6.4
On-chip Cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.5
Translation Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6.6
Halt Protected Space . . . . . . . . . . . . . . . . . . . . . . . . .
4.7
Operating System Bootstrap . . . . . . . . . . . . . . . . . . . . .
4.7.1
Preparing for the Bootstrap . . . . . . . . . . . . . . . . . . . .
4.7.2
Primary Bootstrap Procedures (VMB) . . . . . . . . . . . .
4.7.3
Device Dependent Secondary Bootstrap Procedures . .
4.7.3.1
Disk and Tape Bootstrap Procedure . . . . . . . . . . . .
4.7.3.2
PROM Bootstrap Procedure . . . . . . . . . . . . . . . . . .
4.7.3.3
MOP Ethernet Functions and Network Bootstrap
Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.3.4
Network "Listening" . . . . . . . . . . . . . . . . . . . . . . . .
4.8
Operating System Restart . . . . . . . . . . . . . . . . . . . . . . .
4.8.1
Locating the RPB . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4–10
4–15
4–20
4–20
4–21
4–21
4–22
4–22
4–22
4–23
4–23
4–23
4–23
4–23
4–24
4–26
4–30
4–30
4–31
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4–32
4–33
4–39
4–40
5.1
Basic Troubleshooting Flow . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2
Product Fault Management and Symptom Directed Diagnosis
5.2.1
General Exception and Interrupt Handling . . . . . . . . . . . .
5.2.2
VMS Error Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.3
VMS Error Logging and Event Log Entry Format . . . . . . .
5.2.4
VMS Event Record Translation . . . . . . . . . . . . . . . . . . . . .
5.2.5
Interpreting CPU Faults Using ANALYZE/ERROR . . . . . .
5.2.6
Interpreting Memory Faults Using ANALYZE/ERROR . . .
5.2.6.1
Uncorrectable ECC Errors . . . . . . . . . . . . . . . . . . . . . . .
5–1
5–3
5–4
5–4
5–7
5–14
5–15
5–17
5–18
Chapter 5 System Troubleshooting and Diagnostics
v
5.2.6.2
5.2.7
5.2.8
Correctable ECC Errors . . . . . . . . . . . . . . . . . . . . . . . . .
Interpreting System Bus Faults Using ANALYZE/ERROR
Interpreting DMA
Host Transaction Faults Using
ANALYZE/ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.9
VAXsimPLUS and System-Initiated Call Logging (SICL)
Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.9.1
Converting the SICL Service Request MEL File . . . . . .
5.2.9.2
VAXsimPLUS Installation Tips . . . . . . . . . . . . . . . . . . .
5.2.9.3
VAXsimPLUS Post-Installation Tips . . . . . . . . . . . . . . .
5.2.10 Repair Data for Returning FRUs . . . . . . . . . . . . . . . . . . . .
5.3
Interpreting Power-On Self Test (POST) and ROM-Based
Diagnostic (RBD) Failures . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.1
FE Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.2
Overriding Halt Protection . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.3
Isolating Memory Failures . . . . . . . . . . . . . . . . . . . . . . . . .
5.4
Testing DSSI Storage Devices . . . . . . . . . . . . . . . . . . . . . . . .
5.5
Using MOP Ethernet Functions to Isolate Failures . . . . . . . .
5.6
Interpreting User Environmental Test Package (UETP) VMS
Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.6.1
Interpreting UETP Output . . . . . . . . . . . . . . . . . . . . . . . .
5.6.1.1
UETP Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.6.1.2
Possible UETP Errors . . . . . . . . . . . . . . . . . . . . . . . . . .
5.7
Using Loopback Tests to Isolate Failures . . . . . . . . . . . . . . . .
5.7.1
Testing the Console Port . . . . . . . . . . . . . . . . . . . . . . . . . .
5.7.2
Embedded DSSI Loopback Testing . . . . . . . . . . . . . . . . . . .
5.7.3
Embedded Ethernet Loopback Testing . . . . . . . . . . . . . . . .
5.7.4
Q-Bus Option Loopback Testing . . . . . . . . . . . . . . . . . . . . .
5–21
5–26
5–28
5–30
5–35
5–36
5–37
5–38
5–38
5–51
5–52
5–52
5–55
5–57
5–60
5–60
5–60
5–61
5–62
5–64
5–65
5–66
5–67
Chapter 6 FEPROM Firmware Update
6.1
6.2
6.3
6.4
vi
Preparing the Processor for an FEPROM Update
Updating Firmware Via Ethernet . . . . . . . . . . . .
Updating Firmware Via Tape . . . . . . . . . . . . . . . .
FEPROM Update Error Messages . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6–2
6–3
6–6
6–9
Appendix A KA675/KA680/KA690 Firmware Commands
A.1 Console I/O Mode Control Characters . . . . . . . .
A.1.1
Command Syntax . . . . . . . . . . . . . . . . . . . . . .
A.1.2
Address Specifiers . . . . . . . . . . . . . . . . . . . . .
A.1.3
Symbolic Addresses . . . . . . . . . . . . . . . . . . . .
A.1.4
Console Numeric Expression Radix Specifiers
A.1.5
Console Command Qualifiers . . . . . . . . . . . . .
A.1.6
Console Command Keywords . . . . . . . . . . . . .
A.2 Console Commands . . . . . . . . . . . . . . . . . . . . . .
A.2.1
BOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.2
CONFIGURE . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.3
CONTINUE . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.4
DEPOSIT . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.5
EXAMINE . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.6
FIND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.7
HALT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.8
HELP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.9
INITIALIZE . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.10 MOVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.11 NEXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.12 REPEAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.13 SEARCH . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.14 SET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.15 SHOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.16 START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.17 TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.18 UNJAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2.19 X—Binary Load and Unload . . . . . . . . . . . . .
A.2.20 ! (Comment) . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
A–1
A–2
A–3
A–3
A–6
A–6
A–8
A–9
A–10
A–11
A–14
A–14
A–15
A–16
A–17
A–17
A–19
A–20
A–21
A–23
A–23
A–25
A–29
A–33
A–33
A–34
A–34
A–36
vii
Appendix B Address Assignments
B.1
B.2
B.3
B.4
B.5
B.6
KA675/KA680/KA690 General Local Address Space Map
KA675/KA680/KA690 Detailed Local Address Space Map
External, Internal Processor Registers . . . . . . . . . . . . . . .
Global Q22–bus Address Space Map . . . . . . . . . . . . . . . .
Processor Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IPR Address Space Decoding . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
. B–1
. B–2
. B–8
. B–8
. B–9
. B–16
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
C–1
C–3
C–3
C–4
C–5
C–5
C–6
C–7
C–7
Halt Dispatch State Machine . . . . . . . . . . . . . . . . . . . . . . . . .
RPB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMB Argument List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D–1
D–6
D–9
Appendix C ROM Partitioning
C.1 Firmware EPROM Layout . . . . . . .
C.1.1
System Identification Registers .
C.1.1.1
PR$_SID (IPR 62) . . . . . . . . .
C.1.1.2
SIE (20040004) . . . . . . . . . . .
C.1.2
Call-Back Entry Points . . . . . . .
C.1.2.1
CP$GETCHAR_R4 . . . . . . . . .
C.1.2.2
CP$MSG_OUT_NOLF_R4 . . .
C.1.2.3
CP$READ_WTH_PRMPT_R4
C.1.3
Boot Information Pointers . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Appendix D Data Structures and Memory Layout
D.1
D.2
D.3
Appendix E Configurable Machine State
Appendix F NVRAM Partitioning
F.1
SSC RAM Layout . . . . . . . . . . . . . . . . .
F.1.1
Public Data structures . . . . . . . . . . .
F.1.2
Console Program MailBox (CPMBX)
F.1.3
Firmware Stack . . . . . . . . . . . . . . . .
F.1.4
Diagnostic State . . . . . . . . . . . . . . . .
F.1.5
USER Area . . . . . . . . . . . . . . . . . . .
viii
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
F–1
F–1
F–2
F–3
F–3
F–4
Appendix G MOP Counters
Appendix H Programming the KFQSA Adapter
Appendix I Error Messages
I.1
I.2
I.3
I.4
Machine Check Register Dump
Halt Code Messages . . . . . . . . .
VMB Error Messages . . . . . . . .
Console Error Messages . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
I–1
I–1
I–3
I–4
Appendix J Related Documents
Glossary
Index
Examples
3–1
3–2
3–3
SHOW DSSI Display (Embedded DSSI) . . . . . . . . . . . . .
SHOW UQSSP Display (KFQSA-Based DSSI) . . . . . . . .
Accessing the DUP Driver Utility From Console Mode
(Embedded DSSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–4 Accessing the DUP Driver Utility From Console Mode
(KFQSA-Based DSSI) . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–5 Accessing the DUP Driver Utility From VMS . . . . . . . .
3–6 Setting Allocation Class for a Specified Device . . . . . . .
3–7 Setting a Unit Number for a Specified Device . . . . . . . .
3–8 Changing a Node Name for a Specified Device . . . . . . . .
3–9 Changing a System ID for a Specified Device . . . . . . . .
3–10 Exiting the DUP Driver Utility for a Specified Device . .
3–11 SHOW DSSI Display . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–12 SHOW UQSSP Display (KFQSA-Based DSSI) . . . . . . . .
. . . . 3–29
. . . . 3–30
. . . . 3–31
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3–31
3–32
3–33
3–34
3–36
3–37
3–38
3–38
3–39
ix
3–13
3–14
4–1
4–2
4–3
4–4
5–1
5–2
5–3
5–4
5–5
5–6
5–7
5–8
5–9
5–10
5–11
5–12
5–13
5–14
6–1
6–2
Setting Hardware Write-Protection Through Firmware . . . . .
Setting Hardware Write-Protection Through VMS . . . . . . . . .
Language Selection Menu . . . . . . . . . . . . . . . . . . . . . . . . . . .
Normal Diagnostic Countdown . . . . . . . . . . . . . . . . . . . . . . . .
Successful Power-Up to List of Bootable Devices . . . . . . . . . .
Test 9E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Log Entry Indicating CPU Error . . . . . . . . . . . . . . . . .
SHOW ERROR Display Using VMS . . . . . . . . . . . . . . . . . . . .
Error Log Entry Indicating Uncorrectable ECC Error . . . . . .
SHOW MEMORY Display Under VMS . . . . . . . . . . . . . . . . .
Using ANALYZE/SYSTEM to Check the Physical Address in
Memory for a Replaced Page . . . . . . . . . . . . . . . . . . . . . . . . .
Error Log Entry Indicating Correctable ECC Error . . . . . . . .
Error Log Entry Indicating Q-Bus Error . . . . . . . . . . . . . . . .
Error Log Entry Indicating Polled Error . . . . . . . . . . . . . . . .
Device Attention Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SICL Service Request with Appended MEL File . . . . . . . . . .
Sample Output with Errors . . . . . . . . . . . . . . . . . . . . . . . . . .
FE Utility Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Running DRVTST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Running DRVEXR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FEPROM Update Via Ethernet . . . . . . . . . . . . . . . . . . . . . . .
FEPROM Update Via Tape . . . . . . . . . . . . . . . . . . . . . . . . . .
3–42
3–43
4–3
4–4
4–7
4–12
5–16
5–17
5–18
5–20
5–21
5–24
5–27
5–28
5–30
5–36
5–38
5–51
5–56
5–57
6–5
6–8
Figures
2–1
2–2
2–3
2–4
2–5
2–6
2–7
2–8
2–9
2–10
2–11
x
KA675/KA680/KA690 CPU Module Component Side . . . . .
KA675/KA680/KA690 Kernel System Functional Diagram
KA675/KA680/KA690 CPU Module Block Diagram . . . . . .
Ratchet Handles for CPU and Memory Modules . . . . . . . .
H3604 Console Module (Front) . . . . . . . . . . . . . . . . . . . . . .
H3604 Console Module (Back) . . . . . . . . . . . . . . . . . . . . . .
System Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BA440 Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Speed Control (FSC) Jumper Location . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2–2
2–4
2–5
2–6
2–7
2–10
2–12
2–14
2–15
2–18
2–19
3–1
3–2
3–3
3–4
3–5
Memory Module Ratchet Handles . . . . . . . . . . . . . . . . . . . . .
Storage Configuration Example . . . . . . . . . . . . . . . . . . . . . . .
Sample Power Bus Configuration . . . . . . . . . . . . . . . . . . . . . .
VAX 4000 Model 500 Configuration Worksheet . . . . . . . . . . .
DSSI Cabling for a Generic Two-System DSSI VAXcluster
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–6 Two-System DSSI VAXcluster . . . . . . . . . . . . . . . . . . . . . . . .
3–7 Expanded Two-System DSSI VAXcluster . . . . . . . . . . . . . . . .
3–8 VMS Operating System Requires Unique Unit Numbers for
DSSI Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–9 Sample DSSI Busses for an Expanded VAX 4000 Model 500
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–10 Attaching a MSCP Unit Number Label to the Device Front
Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–1 Console Banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–2 Memory Layout after Power-up Diagnostics . . . . . . . . . . . . . .
4–3 Memory Layout prior to VMB Entry . . . . . . . . . . . . . . . . . . .
4–4 Memory Layout at VMB Exit . . . . . . . . . . . . . . . . . . . . . . . . .
4–5 Boot Block Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–6 Locating the Restart Parameter Block . . . . . . . . . . . . . . . . . .
5–1 Event Log Entry Format . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–2 Machine Check Stack Frame Subpacket . . . . . . . . . . . . . . . .
5–3 Processor Register Subpacket . . . . . . . . . . . . . . . . . . . . . . . .
5–4 Memory Subpacket for ECC Memory Errors . . . . . . . . . . . . .
5–5 Memory SBE Reduction Subpacket (Correctable Memory
Errors) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–6 CRD Entry Subpacket Header . . . . . . . . . . . . . . . . . . . . . . . .
5–7 Correctable Read Data (CRD) Entry . . . . . . . . . . . . . . . . . . .
5–8 Trigger Flow for the VAXsimPLUS Monitor . . . . . . . . . . . . . .
5–9 Five-Level VAXsimPLUS Monitor Display . . . . . . . . . . . . . . .
5–10 H3604 Console Module Fuses . . . . . . . . . . . . . . . . . . . . . . . .
6–1 Firmware Update Utility Layout . . . . . . . . . . . . . . . . . . . . . .
6–2 W4 Jumper Setting for Updating Firmware . . . . . . . . . . . . . .
C–1 KA675/KA680/KA690 FEPROM Layout . . . . . . . . . . . . . . . . .
C–2 SID : System Identification Register . . . . . . . . . . . . . . . . . . .
C–3 SIE : System Identification Extension (20040004) . . . . . . . . .
C–4 Boot Information Pointers . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–3
3–7
3–9
3–11
3–14
3–17
3–18
3–26
3–27
3–35
4–5
4–21
4–26
4–29
4–31
4–40
5–8
5–9
5–10
5–11
5–11
5–12
5–13
5–32
5–34
5–64
6–2
6–3
C–2
C–3
C–4
C–8
xi
F–1
F–2
F–3
F–4
KA675/KA680/KA690 SSC NVRAM Layout . . . . . . . . . . .
NVR0 (20140400) : Console Program MailBoX (CPMBX)
NVR1 (20140401) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NVR2 (20140402) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
F–1
F–2
F–3
F–3
2–1 KA675/KA680/KA690 CPU Module Components . . . . . . . . . .
2–2 H3604 Console Module (Front) . . . . . . . . . . . . . . . . . . . . . . . .
2–3 H3604 Console Module (Back) . . . . . . . . . . . . . . . . . . . . . . . .
2–4 System Control Panel (SCP) . . . . . . . . . . . . . . . . . . . . . . . . .
2–5 H7874 Power Supply Switches, Controls,
and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–1 BA440 Module Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–2 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–3 Boot Devices Supported by the KA675/KA680/KA690 . . . . . .
3–4 Virtual Memory Bootstrap (VMB) Boot Flags . . . . . . . . . . . .
3–5 Actions Taken on a Halt . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–1 Language Inquiry on Power-Up or Reset . . . . . . . . . . . . . . . .
4–2 LED Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–3 Scripts Available to Customer Services . . . . . . . . . . . . . . . . .
4–4 Signature Field Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–5 Network Maintenance Operations Summary . . . . . . . . . . . . .
4–6
Supported MOP Messages . . . . . . . . . . . . . . . . . . . . . . . . . .
4–7 MOP Multicast Addresses and Protocol Specifiers . . . . . . . . .
5–1 Console Terminal/Console Module Problems . . . . . . . . . . . . .
5–2 Power Supply Status Indicators . . . . . . . . . . . . . . . . . . . . . . .
5–3 VMS Error Handler Entry Types . . . . . . . . . . . . . . . . . . . . . .
5–4 Conditions That Trigger VAXsimPLUS Notification and
Updating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–5 Five-Level VAXsimPLUS Monitor Screen Display . . . . . . . . .
5–6 Machine Check Exception During Executive . . . . . . . . . . . . .
5–7 Exception During Executive with No Parameters . . . . . . . . .
5–8 Other Exceptions with Parameters, No Machine Check . . . . .
5–9 KA675/KA680/KA690 Console Displays As Pointers to FRUs
5–10 H3604 Console Module Fuses . . . . . . . . . . . . . . . . . . . . . . . .
5–11 Loopback Connectors for Common Devices . . . . . . . . . . . . . .
2–3
2–8
2–10
2–13
Tables
xii
2–15
3–1
3–12
3–45
3–46
3–47
4–2
4–6
4–14
4–17
4–35
4–36
4–38
5–3
5–3
5–7
5–31
5–33
5–40
5–41
5–41
5–43
5–63
5–68
A–1
A–2
A–3
A–4
A–5
A–6
B–1
B–2
C–1
C–2
C–3
D–1
D–2
D–3
F–1
F–2
F–3
G–1
H–1
I–1
I–2
I–3
Console Symbolic Addresses . . . . . . . . . . . . . . . .
Symbolic Addresses Used in Any Address Space
Console Radix Specifiers . . . . . . . . . . . . . . . . . .
Console Command Qualifiers . . . . . . . . . . . . . . .
Command Keywords by Type . . . . . . . . . . . . . . .
Console Command Summary . . . . . . . . . . . . . . .
Processor Registers . . . . . . . . . . . . . . . . . . . . . .
IPR Address Space Decoding . . . . . . . . . . . . . . .
System Identification Register . . . . . . . . . . . . . .
System Identification Extension . . . . . . . . . . . . .
Call-Back Entry Points . . . . . . . . . . . . . . . . . . .
Firmware State Transition Table . . . . . . . . . . . .
Restart Parameter Block fields . . . . . . . . . . . . .
VMB Argument List . . . . . . . . . . . . . . . . . . . . . .
......................................
......................................
......................................
MOP Counter Block . . . . . . . . . . . . . . . . . . . . . .
Preferred KFQSA Switch Settings . . . . . . . . . . .
HALT Messages . . . . . . . . . . . . . . . . . . . . . . . .
VMB Error Messages . . . . . . . . . . . . . . . . . . . .
Console Error Messages . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. A–3
. A–6
. A–6
. A–7
. A–8
. A–8
. B–9
. B–16
. C–3
. C–4
. C–5
. D–2
. D–6
. D–9
. F–2
. F–3
. F–3
. G–1
. H–1
.
I–2
.
I–3
.
I–4
xiii
Preface
This guide describes the procedures and tests used to maintain and
troubleshoot VAX 4000 Model 400, 500, and 600 systems, which use the
KA675, KA680, and KA690 kernel, respectively.
System
Kernel
VAX 4000 Model 400
KA675
VAX 4000 Model 500
KA680
VAX 4000 Model 600
KA690
Intended Audience
This guide is intended for use by Digital Equipment Corporation Service
personnel and qualified self-maintenance customers.
Warnings, Cautions, Notes
Warnings, cautions, and notes appear throughout this guide. They have
the following meanings:
WARNING
Provides information to prevent personal injury.
CAUTION
Provides information to prevent damage to equipment or software.
NOTE
Provides general information about the current topic.
Conventions
A system prompt and a command in boldface, uppercase type, for example,
>>>SHOW DSSI, shows that the user enters the command at the system
prompt.
xiv
Chapter 1
System Maintenance Strategy
Any successful maintenance strategy is predicated on the proper
understanding and use of information services, service tools, service
support and escalation procedures, and field feedback. This chapter lists
the various service tools, information services, and service delivery methods
used in system maintenance.
1.1 Service Delivery Methodology
Before beginning any maintenance operation, you should be familiar with
the following:
1. The site agreement
2. Your local and area geography support and escalation procedures
3. Your Digital Services product delivery plan
Service delivery methods are part of the service support and escalation
procedure. When appropriate, remote services should be part of the initial
system installation. Methods of service delivery include the following:
•
Local support
•
Remote call screening
•
Remote diagnosis and system initiated service requests (using
DSNLink, SICL, MDS01, modem, etc.)
The recommended system installation includes:
1. Hardware installation and acceptance testing. Acceptance testing
(Chapter 4) includes running ROM-based diagnostics and running
MDM to test Q–bus options.
2. Software installation and acceptance testing. For example, using VMS
Factory Installed Software (FIS), and then acceptance testing with
UETP.
3. Installing Symptom-Directed Diagnosis (SDD) and remote diagnosis
tools. This includes installing DSNlink and enabling SICL.
System Maintenance Strategy
1–1
4. Installation of the Symptom-Direct Diagnosis (SDD) toolkit (VAXsimPLUS and SPEAR) and remote services tools and equipment (this includes installing DSNlink, modems, etc., and enabling SICL). When
the installation is complete, the system should be able to dial out using
SICL, and the Digital Service Center should be able to call into the
system. Refer to you remote service delivery strategy.
If your service delivery methodology is not followed, service expenses for
any product could be excessive.
1.2 Product Service Tools and Utilities
This section lists the array of service tools and utilities available for
acceptance testing, diagnosis, and overall serviceability; and provides
recommendations as to their use.
— VMS Error Handling/Logging
VMS provides recovery from errors, fault handling, and event
logging. The Error Report Formatter (ERF) provides bit-to-text
translation of the event logs for interpretation.
RECOMMENDED USE: Analysis of error logs is the primary
method of diagnosis and fault isolation. If the system is up, or
the customer allows the service engineer to bring the system up,
this information should be looked at first. Refer to Section 5.2 for
information on Product Fault Management and Symptom Directed
Diagnosis.
— Symptom-Directed Diagnostic (SDD) Tools (VAXsimPLUS)
SDD tools are used primarily for notification of the existence of
errors that have reached a critical threshold. SDD tools must be
installed during system installation or as soon as product support
is provided. SDD tools are not bundled with VMS.
RECOMMENDED USE: Used primarily for onsite notification to
the user via mail or to a remote Digital support center via System
Initiated Call Logging (SICL). Refer to Section 5.2.9 for information
on VAXsimPLUS and SICL.
— ROM-Based Diagnostics
ROM-based diagnostics have significant advantages:
•
Load time is virtually nonexistent.
•
The boot path is more reliable.
1–2 KA675/KA680/KA690 CPU System Maintenance
•
Diagnosis is done in a more primitive state.
RECOMMENDED USE: The CPU ROM-based diagnostic facility
is the primary means of offline testing and diagnosis of the
CPU, memory, Ethernet, and DSSI subsystems. The ROM-based
diagnostics are used in the acceptance test procedures (Section 4.4)
when installing a system, adding a memory module, or replacing
the following: CPU module, memory module(s), backplane, DSSI
device, or H3604 console module. Use the ROM-based diagnostic
error messages in Table 5–9 to isolate FRUs.
— Firmware Console Commands
Several commands and utilities are needed in configuring a system
and setting and examining system and device parameters. For
example, the CONFIGURE command is used to determine the
proper CSR addresses for modules; the SHOW MEMORY, SHOW
DSSI, and SHOW QBUS commands are used to examine the
configuration; and the SET HOST command is used to access the
DUP driver to configure DSSI parameters.
RECOMMENDED USE: Use console commands to configure
the system and in setting and examining device parameters.
Refer to Section 3.7 for information on firmware commands and
utilities. Appendix A provides information on all available console
commands.
— Option LEDs During Power-Up
Many options and modules have LEDs that display pass/fail selftest results.
RECOMMENDED USE: Monitor option and module LEDs during
power-up to see if they pass their self-tests. Refer to Sections 4.2.2
and 4.2.3 for information on power-up tests for Q–bus and mass
storage devices. For more information on individual options, refer
to your Microsystems Options manual.
— Operating System Exercisers (VMS UETP)
The User Environment Test Package (UETP) is a VMS software
package designed to test whether the VMS operating system is
installed correctly.
System Maintenance Strategy
1–3
RECOMMENDED USE: Use UETP as part of acceptance testing to
ensure that VMS is correctly installed. UETP is also used to stress
test the user’s environment and configuration by simulating system
operation under heavy loads.
— MicroVAX Diagnostic Monitor (MDM)
The loadable diagnostic MDM requires a minimum of Release 136
to support VAX 4000 Model 500 systems. Consult your MicroVAX
Diagnostic Monitor User’s Guide for instructions on running MDM.
RECOMMENDED USE: MDM is used primarily for testing Q–bus
options.
— Loopback Tests
Internal and external loopback tests can be used to isolate a failure
by testing segments of a particular control or data path. The
loopback tests are a subset of the ROM-based diagnostics.
RECOMMENDED USE: Loopback tests can be used to isolate
problems with the console port, DSSI adapters, Ethernet controller,
and many common Q–bus options. Refer to Section 5.7 for
instructions on performing loopback tests.
— Crash Dumps
For fatal errors, VMS will save the contents of memory to a crash
dump file, e.g. fatal bugchecks.
RECOMMENDED USE: Crash dump file analysis should be
performed by support. Saving a crash dump file for analysis
requires proper system settings. Refer to your VMS documentation
for instructions.
1.3 Information Services
Digital service engineers may access several information resources,
including advanced database applications, online training courses, and
remote diagnosis tools. A brief description of some of these resources
follows.
— Technical Information Management Architecture (TIMA)
TIMA is used by Digital Services to deliver technical and reference
information to its service engineers. One of the main benefits of
TIMA is the pooling of worldwide knowledge and expertise.
1–4 KA675/KA680/KA690 CPU System Maintenance
— Entry Systems Service Information Kits
Service documentation containing information on enclosures, CPUs,
and options, makes up the Entry Systems Service Information Kit.
The manual you are reading is part of the kit. Refer to your Guide
to Entry Systems Service Information Kits (EK–276A*–MI) for more
information.
— Training
Computer Based Instruction (CBI) and lecture lab courses are
available from the Digital training center:
•
VAX 4000 Model 500 System Installation and Troubleshooting
(CBI course, EY–I089E–EO)
•
MicroVAX Installation and Troubleshooting (Lecture lab course,
EY–9408E–LO)
— Digital Services Product Delivery Plan (Hardware or Software)
The Product Delivery Plan documents Digital Services delivery
commitments.
The plan is the communications vehicle used
among the various groups responsible for ensuring consistency
between Digital Services delivery strategies and engineering
product strategies.
— Blitzes
Technical updates are ‘‘blitzed’’ to the field using mail and TIMA.
— Storage and Retrieval System (STARS)
Stars is a worldwide database for storing and retrieving technical
information. The STARS databases, which contain more than
150,000 entries, are updated daily.
Using STARS, a service specialist can quickly retrieve the most upto-date technical information via DSNlink or DSIN.
— VAX Notes
VAX Notes is a worldwide notesfile.
— DSNlink
DSNlink software application lets the Digital Services Center
communicate electronically with the customer site. DSNlink serves
as the platform for the delivery of electronic services.
System Maintenance Strategy
1–5
1.4 Field Feedback
Providing the proper feedback to the corporation is essential in closing the
loop on any service call. Consider the following when completing a service
call:
•
Repair tags should be filled out accurately and with as much symptom
information as possible so that repair centers can fix a problem.
•
Call closeout information for Labor Activity Reporting System (LARS)
or Call-Handling and Management Planning (CHAMP) needs to be
accurate.
•
The site maintenance log, whether hardcopy or electronic, should
provide a chronicle of the performed maintenance.
1–6 KA675/KA680/KA690 CPU System Maintenance
Chapter 2
CPU System Overview
This chapter provides an overview of the components that make up KA675
/KA680/KA690-based systems. These components are listed below:
•
CPU: KA675 (L4002–CA), KA680 (L4002–BA), or KA690 (L4002–AA)
•
MS690 memory modules
•
BA440 enclosure components
H3604 console module
System Control Panel (SCP)
BA440 Backplanes
Power supply
Fans
CAUTION: Static electricity can damage integrated circuits. Always use a
grounded wrist strap (PN 29–11762–00) and grounded work surface when
working with the internal parts of a computer system.
2.1 CPU Module Features
The KA675/KA680/KA690 is a quad-height VAX processor module that uses
the Q22–bus and DSSI bus. The CPUs are used in the following systems:
System
CPU
VAX 4000 Model 400
KA675
VAX 4000 Model 500
KA680
VAX 4000 Model 600
KA690
The CPU module is designed for use in high-speed, real-time applications
and for multiuser, multitasking environments. The KA675/KA689/KA690
employs multiple levels of cache memory to maximize performance. See
Figure 2–1 for a view of the major chips, LEDs, and connectors. See
Figure 2–2 and Figure 2–3 for block diagrams of the major functions.
CPU System Overview
2–1
The CPU module and MS690 memory modules combine to form the CPU
/memory subsystem that uses DSSI busses to communicate with mass
storage devices, the Q22–bus to communicate with I/O devices, and the
Ethernet to communicate across the network.
The CPU module is configured as an arbiter CPU on the Q22–bus, where
it arbitrates bus mastership and fields any on-board interrupt requests.
Figure 2–1: KA675/KA680/KA690 CPU Module Component Side
Console Connector, J2
E-Net ROM
Run LED
Firmware
Diagnostic LEDs
BCache
(Tag
Store)
DC246
NVAX
B-CACHE
(Data Store)
DC542
SHAC
DC541
SGEC
DC243
NCA
CLK
ROMs
DC511
SSC
Obit RAMs
DC244
NMC
DC527
CQBIC
DC542
SHAC
Backplane Connector, J1
MLO-007693
2–2 KA675/KA680/KA690 CPU System Maintenance
Table 2–1: KA675/KA680/KA690 CPU Module Components
Components
Function
DC246 (NVAX)
Central processor unit. Contains a 64 entry translation
buffer integral floating point unit, 2-KB virtual instruction
stream cache (VIC), 8-KB physical instruction and data
stream primary cache (P-cache), and backup cache control
and error correction code (ECC)
KA675: Central processor unit has 16-ns cycle time and
the virtual instruction stream cache is disabled
KA680: Central processor unit has 14-ns cycle time
KA690: Central processor unit has 12-ns cycle time
Backup cache RAMs
KA675, KA680: 128-KB backup cache (B-cache)
KA690: 512-KB backup cache (B-cache)
DC243 (NCA)
NDAL to CDAL I/O bus interface chip
DC244 (NMC)
Main memory controller (also provides ECC protection)
DC527 (CQBIC)
Q22–bus interface
DC541 (SGEC)
Ethernet interface
Ethernet Station Address ROM
Provides unique hardware address
DC542 (SHAC)
DSSI interface chips (2)
DC511 (SSC)
System Support Chip
DC509 (CLK)
Clock
Firmware ROMs
Four resident firmware chips, each 128 K by 8 bits of
FLASH programmable EPROMS for a total of 512 KB.
Obit RAMs
The ECC protected ownership-bit RAMs provide coherency
between backup cache and memory.
Console connector
100-pin for connection to the H3604 console module (J2)
Backplane connector
270-pin for connection to backplane for Q22–bus, DSSI
bus, and memory interconnect (J1)
Run LED
This LED indicates the CPU module is receiving power.
Diagnostic LEDs
A hexadecimal value displays on the four diagnostic LEDs.
The values correspond to the decimal value displayed on
the H3604 console module LED.
CPU System Overview
2–3
Figure 2–2: KA675/KA680/KA690 Kernel System Functional Diagram
Backplane Interconnect
Serial Line
H3604 Ribbon
Console Cable
Module
KA680
CPU
Module
Backplane Connector
(270-Pin)
Ethernet
Console Connector
(100-Pin)
DSSI Bus #1
DSSI Bus #0
To Mass Storage
Slots
Q22-bus
To Q22-bus Slots
NMI Bus (150 Pin)
MS690 Memory Modules
(1 minimum/4 maximum)
MLO-007694
2–4 KA675/KA680/KA690 CPU System Maintenance
Figure 2–3: KA675/KA680/KA690 CPU Module Block Diagram
To Console Module
NCA
NDAL
DSSI
SHAC2
DSSI
SGEC
Ethernet
To Console
Module
Q22-bus
To BA440
Backplane
CDAL 1
NVAX
CPU
SSC
Bcache
SHAC1
Pcache
ROM
VIC
CDAL 2
CQBIC
NMC
To BA440
Disks
To Memory
MLO-007262
2.2 MS690 Memory Modules
The MS690 memory module is a double-sided, quad-height memory board
that uses a 150-pin, high-density connector to communicate to the CPU
module. MS690 memory modules are ECC protected via the NMC chip on
the CPU module.
The MS690 memories are available in three variations:
•
MS690–BA (L4004–BA) 32 MB memory
•
MS690–CA (L4004–CA) 64 MB memory
•
MS690–DA (L4004–DA) 128 MB memory
KA675/KA680/KA690-based systems allows for any combination of up to
four MS690 memory arrays providing a memory capacity from 32 Mbytes
up to 512 Mbytes.
Figure 2–4 shows a sample memory module, which, like the CPU module,
uses ejector handles designed to ensure proper seating of the modules in
the backplane connectors.
CPU System Overview
2–5
Figure 2–4: Ratchet Handles for CPU and Memory Modules
Ejector
Handles
MLO-004227
2.3 BA440 Enclosure Components
KA675/KA680/KA690-based systems use the BA440 enclosure. A brief
description of the components that make up the BA440 enclosure follows.
For information on FRU removal and replacement procedures refer to the
BA430/BA440 Enclosure Maintenance manual.
2.3.1 H3604 Console Module
The H3604 console module covers the five slots dedicated to the CPU
and memory modules (one slot for the KA675/KA680/KA690, and four
available slots for MS690 memory modules). Switches on the console
module allow you to configure the kernel. The console module also provides
2–6 KA675/KA680/KA690 CPU System Maintenance
the connectors for a serial line console device, an external DSSI bus, and
the Ethernet. See Figures 2–5 and 2–6.
Figure 2–5: H3604 Console Module (Front)
Console Module
Power-Up
Mode Switch
Baud Rate
Select Switch
Console Jack
Baud
300___________0
600___________1
1200__________2
2400__________3
4800__________4
9600__________5
19200_________6
38400_________7
Break Enable/
Disable Switch
Bus 0
LED Display
Bus 1
Y
DSSI
Connectors
(External Bus,
Bus 1)
X
Bus Node
ID Plugs
Ethernet
Connector
Switch
Standard
Ethernet
Connector
ThinWire
Ethernet
Connector
MLO-006350
The front of the console module has the components listed in Table 2–2.
CPU System Overview
2–7
Table 2–2: H3604 Console Module (Front)
Control/Indicator
Function
Power-Up Mode Switch
This three-position rotary switch determines how the
system responds at power-up.
Language Inquiry Mode (in the top position, indicated by
a profile of a face) causes the system to display a language
selection menu at power-up if the console terminal has
multi-national character set (MCS) support. Also, if a
default boot device has not been selected, this mode causes
the system to issue a list of bootable devices and prompts
you to select a device from the list. Once a device is
selected, the system autoboots from that device each time
you turn it on.
Run Mode (in the middle position, indicated by an arrow)
is the normal operating setting.
Loopback Test Mode (in the bottom position, indicated by
a T in a circle) causes the system to run loopback tests on
the console serial line at power-up.
Baud Rate Select switch
The Baud Rate Select switch is used to set the system’s
baud rate to match that of the console terminal. The
factory setting is position 5 (9600).
Console serial MMJ connector
This console terminal connector provides the RS-423
interface for the console terminal.
LED Display
The LED displays the testing sequence during power-up.
Break Enable/Disable switch
When the switch is down (position 0), breaks are disabled.
When the switch is up (position 1), breaks are enabled.
When breaks are enabled, pressing Break on the console
terminal halts the processor and transfers control to
the console program. Using the console command SET
CONTROLP, you can specify the control character, Ctrl/P ,
rather than Break to initiate a break signal.
The Break Enable/Disable switch also controls what
happens at power-up. When breaks are disabled (down,
position 0), the system attempts to automatically boot
software at power-up. When breaks are enabled (up,
position 1), the system enters console mode (indicated by
the >>>prompt) at power-up.
Using the console command, SET HALT REBOOT or SET
HALT RESTART_REBOOT, you can set your system to
automatically boot software after the system is halted due
to pressing Break .
2–8 KA675/KA680/KA690 CPU System Maintenance
Table 2–2 (Cont.): H3604 Console Module (Front)
Control/Indicator
Function
Two DSSI bus node ID plugs
KA675/KA680/KA690-based systems have two separate
Digital Storage Systems Interconnect (DSSI) busses. Two
DSSI bus node ID plugs, one for the internal DSSI bus,
Bus 0, and one for the external bus, Bus 1, identify the bus
nodes of the DSSI adapters, which are part of the CPU.
Two DSSI connectors for Bus 1
Two in/out DSSI connectors, labeled X and Y, on the
console module allow you to expand the system by
connecting additional mass storage devices to the second
DSSI bus. You can also share mass storage devices
with another system by forming a DSSI VAXcluster
configuration.
Ethernet port features
The console module has two Ethernet connectors: a
BNC-type connector for ThinWire Ethernet, and a 15pin connector for a standard Ethernet transceiver cable.
The Ethernet connector switch allows you to set the type
of connection. To use the standard transceiver cable
connection, set the switch to the up position. To use the
ThinWire cable connection, set the switch to the down
position. A green indicator light (LED) for each connector
indicates which connection is active.
CPU System Overview
2–9
Figure 2–6: H3604 Console Module (Back)
Battery Backup Unit
W2
W4
J6
J1
J1 = TOY Clock Battery
J5 = H3604 Power
J6 = CPU Interface
W2 = Remote Boot Enable
W4 = FEPROM Write Enable
F2
F4
F1
J5
F3
F1 = ThinWire Ethernet Power, 0.5 A
PN = 12-09159-00
F2 = -12V Power, 0.062 A
PN = 90-09122-00
F3 = DSSI Terminator Power, 2.0 A
PN = 12-10929-06
F4 = Standard Ethernet Power, 1.5 A
PN = 12-10929-08
MLO-006351
The back of the console module has the components listed in Table 2–3.
Table 2–3: H3604 Console Module (Back)
Component
Function
Battery Backup Unit
Provides battery backup power to the SSC RAM.
TOY Clock Battery connector (J1)
Provides the connection between the battery
backup unit and the SSC RAM.
H3604 power connector (J5)
Four-pin power connector to power harness
module.
CPU Interface connector (J6)
100-pin connector to the CPU module.
ThinWire Ethernet Power Fuse (F1)
Protects ThinWire Ethernet.
-12 V Power Fuse (F2)
Protects console serial line.
2–10 KA675/KA680/KA690 CPU System Maintenance
Table 2–3 (Cont.): H3604 Console Module (Back)
Component
Function
DSSI Terminator Power Fuse (F3)
Protects against shorts from the accidental
grounding of the DSSI cable power pin.
Standard Ethernet Power Fuse (F4)
Protects Standard Ethernet.
Remote Boot Enable jumper (W2)
Not used
FEPROM Write Enable jumper (W4)
This jumper must be in the write enable position
to update FEPROMs on the CPU module. Refer
to Chapter 6 for procedures on updating ROMs.
-9 V DC/AC converter
Ethernet serial transceiver chip (SIA)
TOY clock oscillator
Time of year oscillator. Privides TOY singal for
the TOY cock in the system support chip (SSC) on
the CPU module.
CPU System Overview
2–11
2.3.2 System Control Panel (SCP)
The system control panel (SCP) (Figure 2–7) provides the controls to halt
the processor (external halt type) and enter console mode, as well as to
restart the system and return the processor state to power-up and self
tests.
Figure 2–7: System Control Panel
System Control
Panel
Over Temperature
Warning Indicator
DC OK Indicator
Halt Button
Restart Button
MLO-008652
2–12 KA675/KA680/KA690 CPU System Maintenance
The SCP has the controls and indicators listed in Table 2–4.
Table 2–4: System Control Panel (SCP)
Control/Indicator
Function
Over Temperature Warning indicator
The red Over Temperature Warning indicator flashes
to indicate that the system’s internal temperature is
approaching a level that may cause system components to
overheat. In addition to the flashing Over Temperature
Warning indicator, an audible alarm also provides
warning of a possible over temperature condition. If
the components continue to heat, the system will
automatically shut down to prevent components from
being damaged.
DC OK indicator
The green DC OK indicator shows that the power supply
voltages are within the correct operating range.
Halt Button
The Halt button is a two-position button. When you press
the button, the system halts. A red indicator on the Halt
button lights when the button is set to the in position.
Before you can enter console commands, press the Halt
button again to return it to the out position. When the Halt
button is returned to the out position, the console mode
prompt >>> is displayed on the console terminal screen.
Now you can enter console commands. If you inadvertently
press the Halt button, type ‘‘c Return ’’ to continue.
CAUTION: Pressing the Halt button halts the
system regardless of the setting of the Break
Enable/Disable switch on the console module.
Restart Button
The Restart button has a green indicator. When you
press the Restart button, the system returns to a powerup condition and self-tests are run. If you have specified a
device as the boot device and if the Break/Enable Disable
switch is set to disable, the system will reboot system
software.
CPU System Overview
2–13
2.3.3 BA440 Backplane
KA675/KA680/KA690-based systems use the 54–19354–01 backplane,
shown in Figure 2–8.
Figure 2–8: BA440 Backplane
SCSI Connector
(Later Revision Only)
Vterm Module
SCP
Connector
Mass Storage
Connectors
Power Supply
Connectors
Module
Connectors
12 11 10 9 8 7 6
Q-bus
Option
5
CPU
4 3 2 1
Fan Connector
Memory
Power
Board
for H3604
MLO-007695
2–14 KA675/KA680/KA690 CPU System Maintenance
2.3.4 Power Supply
The BA440 enclosure uses the H7874 power supply (Figure 2–9). Table 2–5
describes the power supply components.
Figure 2–9: Power Supply
Power Switch
AC Present Indicator
DC OK Indicator
Fan Failure
Indicator
Over Temperature
Condition Indicator
Power Bus
Connectors
Power Cable
Connector
MLO-004040
Table 2–5: H7874 Power Supply Switches, Controls,
and Indicators
Control/Indicator
Function
AC Present indicator (orange)
Lights when the power switch is set to on (1), and the ac
voltage is present at the input of the power supply.
CPU System Overview
2–15
Table 2–5 (Cont.): H7874 Power Supply Switches, Controls,
and Indicators
Control/Indicator
Function
Power switch
The power switch is used to turn system power on and
off. The off position is indicated by a 0; the on position is
indicated by a 1.
The power switch also functions as the system
circuit breaker. In the event of a power surge, the breaker
will trip causing the power switch to return to the off position (0). Turning on the system resets the circuit breaker.
If the circuit breaker trips, wait one minute before turning
the system back on.
DC OK indicator (green)
When the DC OK indicator is lit, the voltages are within
the correct operating range. An unlit DC OK indicator
shows a problem with the power supply.
Fan Failure indicator (amber)
The Fan Failure indicator lights if either of the two cooling
fans stops working. The power supply will automatically
shut down the system as a precautionary measure when a
fan failure is detected.
Over Temperature
(amber)
The Over Temperature indicator lights if the system has
shut down due to an over temperature condition.
Power bus connectors
indicator
Three power bus connectors allow you to configure a power
bus for systems expanded with a system expander. The
power bus allows you to turn power on and off for the
system through one power supply designated as the main
power supply: this way, one power switch can control
power for an expanded system.
NOTE: DSSI VAXcluster systems should not
be configured with a power bus. Inadvertently
shutting off a host system and bringing down
the cluster defeats the added reliability of a
DSSI VAXcluster.
MO
The main out connector sends the power control bus signal
to the expander. One end of a power bus cable is connected
here; the other end is connected to the SI (secondary in)
connector of the expander power supply.
2–16 KA675/KA680/KA690 CPU System Maintenance
Table 2–5 (Cont.): H7874 Power Supply Switches, Controls,
and Indicators
Control/Indicator
Function
SI
The secondary in connector receives the power bus control
signal from the main power supply. In a power bus with
more than one expander, the power bus signal is passed
along using the secondary in and out connectors.
SO
The secondary out connector sends the signal down the
power bus for configurations of more than one expander.
2.3.5 System Airflow
Two fans are located under the card cage (Figure 2–10) . The power supply
monitors the fans. If either fan stops working, the Fan Failure indicator
on the power supply lights, and the system automatically shuts down as a
precautionary measure.
CPU System Overview
2–17
Figure 2–10: Fans
Captive Screws
MLO-004220
Some system managers request that the fans run at the maximum rate
at all times to take advantage of a potential increase in system reliability.
The system environment must not exceed the limits described in the Site
Preparation manual. Figure 2–11 shows the location of the fan speed control
(FSC) jumper on the bottom of the power supply. Setting the FSC jumper
to disable causes the fans to run at the maximum rate.
2–18 KA675/KA680/KA690 CPU System Maintenance
Figure 2–11: Fan Speed Control (FSC) Jumper Location
FSC
Enabled
(Factory
Setting)
FSC
Disabled
MLO-004204
CPU System Overview
2–19
Chapter 3
System Setup and Configuration
This chapter describes the guidelines for the configuration of a KA675
/KA680/KA690-based system. Configuration issues covered in this chapter
include module order, mass storage configurations, system expansion, DSSI
VAXcluster configurations, and firmware commands and utilities used in
system configuration.
3.1 CPU and Memory Module Order
The five rightmost BA440 backplane slots are dedicated to CPU and
memory modules. The seven slots to the left are for Q–bus modules. See
Table 3–1.
Table 3–1: BA440 Module Order
Slot
Module
1 through 4
Reserved for up to four MS690 memory modules. MS690 modules
are installed from left to right with no gaps: first memory module
in slot 4, second memory module in slot 3, and so on.
NOTE: Proper placement of memory modules is
necessary for FRU isolation using error logs.
5
CPU module: KA675 (L4002–CA), KA680 (L4002–BA), KA690
(L4002-AA)
6 through 12
Q–bus options
A system can have up to four memory modules. Memory modules are
available in 32 MB (MS690–BA), 64 MB (MS690–CA), and 128 MB (MS690–
DA), and can be used in any combination. The firmware logically configures
the memory modules at power-up.
System Setup and Configuration
3–1
3.1.1 Installing Add-On MS690 Memory Modules
Perform the following steps to install add-on MS690 memory module(s). You
do not set any jumpers or switches on the memory module. The memory
address for the memory module is mapped by the system.
CAUTION: Turn off the system before installing modules. Installing
modules while this system is powered-up can damage the modules.
1. Two captive screws hold the console module (H3604) in place. To loosen,
both screws should be turned counterclockwise. The console module is
hinged on the left. Swing the assembly open.
NOTE: Two cables connect to the H3604 console module: a ribbon
cable which connects to the CPU module; and a four-pin power harness
connects to a power harness module (also known as the power board
H3604) which plugs into the backplane. The power harness module is
located directly to the right of the CPU module.
2. Install the module(s) starting with the first empty slot, which is located
on the right side of the power harness module. The power harness
module is located between the CPU module (slot 5) and the first memory
module (slot 4).
The memory module(s) must be installed in adjacent slots with no
empty slots between. Slots 12 through 6 are Q–bus slots; slot 5 is
the CPU slot; and slots 4 through 1 are the memory module slots.
3. Make sure the ratchet handles on the memory module on the right
side of the module, and the 150-pin connector is facing to the system.
Wearing the antistatic wrist strap, install the memory module in the
first available memory slot to the right of the CPU. Ensure that the
memory module is vertically aligned. Push the memory module in until
the ratchet handles engage with the enclosure frame. Push the ratchet
handles inward toward the rear of the cabinet until the memory module
is firmly seated in the backplane. When the memory module is firmly
seated, the ratchet handles will lock the module in place.
NOTE: The CPU and MS690 memory modules are equipped with
ratchet handles (Figure 3–1) which are shipped in a horizontal position.
The ratchet handles are designed to ensure that the modules are properly
seated in the backplane connectors.
3–2 KA675/KA680/KA690 CPU System Maintenance
Figure 3–1: Memory Module Ratchet Handles
Ejector
Handles
MLO-008453
4. Close the H3604 console module and lock the 1/4-turn captive screws.
5. To identify the memory module, place the MS690 option label (supplied
in the option kit) in the proper location on the H3604 panel. Indicate
the revision number and memory option (BA,CA, or DA).
6. Refer to Chapter 4 for information on initialization and acceptance
testing.
System Setup and Configuration
3–3
3.2 General Module Order for Q-Bus Options
The order of the supported Q–bus options in the backplane depends on four
factors:
•
Relative use of devices in the system
•
Expected performance of each device relative to other devices
•
The ability of a device to tolerate delays between bus requests and bus
grants (called delay tolerance or interrupt latency)
•
The tendency of a device to prevent other devices farther from the CPU
from accessing the bus
The supported options arranged by type are:
Communications
CXA16–AA/AF: 16-line DEC-423 asynchronous controller
CXB16–AA/AF: 16-line RS-422 asynchronous controller
CXY08–AA/AF: 8-line RS-232C asynchronous controller with modem
DEQRA–CA: Token Ring Network Controller
DESQA–SA/SF: ThinWire Ethernet adapter
DFA01–AA/AF: 2400/1200 BPS modem
DIV32–SA/SF: Q–bus ISDN basic rate access interface
DPV11–SA/SF: Q–bus synchronous programmable interface
DRV1W–SA/SF: General purpose 16-bit parallel DMA interface
DRV1J–SA/SF: Q–bus parallel interface
DSV11–SA/SF: Q–bus 2-line synchronous
KMV1A–SA/SF: Single-line programmable controller with DMA
General
ADQ32–SA/SF: 32-channel ADC module
ADV11–SA/SF: 16-channel ADC module
AXV11–SA/SF: 16-channel ADC, 2-channel DAC module
DRQ3B–SA/SF: Q–bus parallel I/O interface
DTC05–SA: Digital encoded voice, multifuction
IBQ01–SA/SF: DECscan/BITBUS controller
IEQ11–SA/SF: Dual-bit DMA serial Q–bus controller
KITHA–AA: Mira AS option
KWV11–SA/SF: Programmable real-time clock
KXJ11–SA: Q–bus peripheral processor with s-box adapter kit
LPV11–SA/SF: Line printer controller
MRV11: Q–bus, universal socket, 32-Kbyte EPROM
VS30U–GA/G3/G4: Graphics option
3–4 KA675/KA680/KA690 CPU System Maintenance
Mass Storage, Tape, Pedestal Expansions
RF35–AA/AF: 852-Mbyte half-height DSSI integrated storage element
RF73E–AA/AF: 2.0-Gbyte full-height DSSI integrated storage element
RF72E–AA/AF: 1.0-Gbyte full-height DSSI integrated storage element
RF71E–AA/AF: 400-Mbyte full-height DSSI integrated storage element
RF31E–AA/AF: 381-Mbyte half-height DSSI integrated storage element
TF85E–JA: 2.6-Gbyte DSSI integrated storage element with 5.25-inch
cartridge
TLZ04–JA/JF/GA: 1.2-Gbyte cassette (DAT) tape drive (requires
KZQSA storage adapter)
TK70E–AA/AF/TQK70–SA/SF: 5.25-inch cartridge, 296-Mbyte tape
drive, tape controller
TK50E–AA/AF/TQK50–SA/SF: 5.25-inch cartridge, 95-Mbyte tape
drive, tape controller
KLESI–SA: Q–bus to LESI adapter
KFQSA–SE/SG: DSSI Q–bus adapter
KZQSA–SA/SF: Storage adapter for TLZ04 tape drive and RRD42
compact disc drive
RA81/82: Storage array (separate cabinets only)
RA90/92: Storage array (separate cabinets only)
KDA50–SE/SG: SDI Q–bus adapter
KRQ50–SA/SF: Q–bus controller for RRD40–DC
TU81E–SA/SB: Magnetic tape (requires KLESI controller)
TSV05–SE/SF/SH/SJ: Q–bus TS05 magnetic tape controller
B400X: Expansion box with 10 Q–bus slots and up to 4 ISEs
R400X–B9: Expansion box with up to 7 RF-series ISEs
RRD40:
600-Mbyte CDROM table-top drive (requires KRQ50
controller)
RRD42: 600-Mbyte tabletop compact disc drive (requires KZQSA
storage adapter)
RSV20–A: WORM optical drive subsystem (requires KLESI controller)
ESE20: Electronic storage element (requires KDA50 controller)
3.3 Recommended Module Order of Q–bus Options
The recommended module order for placement of Q–bus options is provided
in the following list:
MRV11 (Placement not critical)
AAV11
ADV11
AXV11
KWV11
DRV1J
KMV1A
System Setup and Configuration
3–5
DESQA
DPV11
DIV32
VCB02
DFA01
CXA16
CXY08
CXB16
LPV11
DRV1W
KRQ50
IEQ11
ADQ32
DRQ3B
DSV11
KLESI
IBQ01
TSV05 (M7530 controller)
KDA50–SE
KFQSA–SE
KZQSA
TQK50
TQK70
M9060–YA
3.4 Mass Storage Options (Internal)
The mass storage shelf of a BA440 enclosure provides four storage cavities
for embedded mass storage options. The right-most storage cavity can
contain a tape drive (TF85, TK-series, or TLZ04); all four storage cavities
can contain an RF-series ISE.
Combinations of dual-disk, single-disk, or tape ISEs can be used to gain
the full complement of seven DSSI devices on the internal DSSI bus (Bus
0).
VAX 4000 Model 500 systems can support the following combinations of
mass storage options embedded in the system enclosure:
•
One tape drive (TF85, TK-series, or TLZ04) and up to six RF-series
ISEs using the dual-disk RF35.
•
No tape drive and up to seven RF-series ISEs using the dual-disk RF35.
NOTE: The RF35, which has dual-disk capability, can be ordered with a
single disk.
3–6 KA675/KA680/KA690 CPU System Maintenance
Figure 3–2 shows an example of a mass storage configuration consisting of
a TF85 tape drive, two RF35s, and two RF73s.
Figure 3–2: Storage Configuration Example
ISE 3
ISE 2
ISE 1 and 0
Tape Drive
MLO-007696
Rules for Numbering Storage Devices
Use the rules below for numbering (bus node ID and MSCP unit numbers)
storage devices:
•
For each DSSI bus, do not duplicate bus node ID numbers for your
storage devices/adapter. For Bus 0, you can have only one storage
device identified as bus node 0, one storage device as 1, and so on;
for Bus 1, you can have only one storage device identified as bus node
0, one storage device as 1, and so on.
•
The previous rule also applies to DSSI VAXcluster configurations, all
DSSI bus node numbers for storage devices and DSSI adapters must
be unique on a shared DSSI bus.
•
By convention, the RF-series ISEs are numbered in increasing order
from right to left beginning with zero.
•
DSSI adapters use the highest available bus nodes. The next highest
available bus node (usually five) is reserved for the TF85 tape drive.
•
When more than one DSSI bus is being used and the system is using a
nonzero allocation class, you need to assign new MSCP unit numbers
for devices on all but one of the DSSI busses since the unit numbers
for all DSSI devices connected to a system’s associated DSSI busses
must be unique. Refer to Section 3.7.3 for more information on setting
parameters for DSSI devices.
System Setup and Configuration
3–7
NOTE: If you change the bus node ID plugs, power-down the system, change
the plugs and then power-up the system.
3.5 System Expansion
The mass storage and Q–bus capacity of VAX 4000 Model 500 systems can
be increased using the following expanders.
3.5.1 Mass Storage Expanders
•
The R400X mass storage expander provides space for up to seven
additional RF-series ISEs or up to six RF-series ISEs and a tape drive
(TF85 or TLZ04). Using R400X expanders, you can fill both DSSI busses
for a total of 14 DSSI mass storage devices.
NOTE: Using the dual-disk RF35, the R400X can accommodate up to
13 ISEs.
•
The R215F expander provides space for up to three RF-series ISEs.
NOTE: Using the dual-disk RF35, you can increase the number of
ISEs—up to seven ISEs per DSSI bus.
•
The SF100 storage array pedestal provides space for a TF857 magazine
tape subsystem and one SFxx storage array building block.
•
The SF200 storage array subsystem provides space for up to two TF857
magazine tape subsystems and up to six SFxx storage array building
blocks.
3.5.2 Q-Bus Expanders
•
The B400X expander provides 10 additional usable Q–bus slots for a
system total of 17 usable Q–bus slots. The B400X also has space for up
to four additional RF-series ISEs or up to three ISEs and a tape drive
(TF85, TK70, or TLZ04).
NOTE: Using the dual-disk RF35, the B400X can accommodate up to
seven ISEs.
•
The B213F expander also provides 10 additional usable Q–bus slots and
provides space for up to three RF-series ISEs or up to three ISEs and
a TK-series tape drive.
3–8 KA675/KA680/KA690 CPU System Maintenance
NOTE: Installing a B213F or R215F on a VAX 4000 system requires the
H4010–AA expander cable kit.
3.5.3 Control Power Bus for Expanders
The three power bus connectors on the H7874 power supply allow you
to configure a power bus for systems expanded with R400X and B400X
expanders. The power bus allows you to turn power on and off for one or
more expanders through the power supply designated as the main power
supply (Figure 3–3).
NOTE: DSSI VAXcluster systems should not be configured with a power
bus. Inadvertently bringing down the cluster defeats the added reliability
of a DSSI VAXcluster.
Figure 3–3: Sample Power Bus Configuration
System
Expander 1
Expander 2
MLO-004041
3.5.4 Adding Options to the System Enclosure
To determine what options you can add to the system enclosure, you must
list the options currently installed and their power requirements on the
VAX 4000 Model 500 Configuration Worksheet, provided in Figure 3–4.
System Setup and Configuration
3–9
The worksheet in Figure 3–4 is for the BA440 enclosure. All backplane
slots and mass storage devices are powered by the H7874 power supply.
Use the worksheets as follows:
1. In the Module column, list all options and mass storage devices
currently installed in your system. The CPU module has already been
entered.
Use the label on the cover panel of each slot to identify the module
installed in that slot.
2. List each embedded storage device.
3. List the options and mass storage devices you wish to add to your
system.
4. If the system includes a TK70 tape drive, list the TQK70 controller last.
5. Fill in the power requirements for each module and each mass storage
device. The power requirements for the more common options are listed
in Table 3–2.
6. Add each column and make sure the totals do not exceed the specified
limit.
3–10 KA675/KA680/KA690 CPU System Maintenance
Figure 3–4: VAX 4000 Model 500 Configuration Worksheet
Slot
Module
Current (Amps) 1
+5 Vdc +12 Vdc +3.3 Vdc -12 Vdc
Power
Bus Load
(Watts)
AC
DC
MEM 1
MEM 2
MEM 3
MEM 4
CPU
2
L4002-nA 3
4.8
1.6
3.2
0.0
53.8
4.0
1.0
60.0 A
22.0 A
15.0 A
3.0 A
584.0 W
31
20
Q-bus 1
Q-bus 2
Q-bus 3
Q-bus 4
Q-bus 5
Q-bus 6
Q-bus 7
Mass Storage:
1
2
3
4
Total these columns:
Must not exceed:
1. Total output power from +3.3 Vdc and +5 Vdc must not exceed 330 watts.
2. Power requirements in this line include CPU module, H3604 console module,
and backplane terminator combined.
KA690(L4002-AA), KA680(L4002-BA), or KA675(L4002-BC)
MLO-005361
System Setup and Configuration
3–11
Table 3–2: Power Requirements
Current (Amps)
Max
Power
Bus
Loads
Max
Option
Module
+5 V
+12 V
Watts
AC
DC
AAV11–SA
A1009–PA
2.10
0.00
10.50
2.5
0.5
ADQ32–SA
A030
4.45
0.00
22.25
2.5
0.5
ADV11–SA
A1008–PA
2.00
0.00
10.00
2.3
0.5
AXV11–SA
A026–PA
2.00
0.00
10.00
1.2
0.3
CXA16–AA
M3118–YA
1.60
0.20
10.40
3.0
0.5
CXB16–AA
M3118–YB
2.00
0.00
10.00
3.3
0.5
CXY08–AA
M3119–YA
1.64
0.395
12.94
3.0
0.5
DESQA–SA
M3127–PA
2.40
0.22
14.64
3.3
0.5
DEQRA–CA
M –PA
4.0
1.0
21.20
2.2
0.5
DFA01–AA
M3121–PA
1.97
0.04
10.30
3.0
1.0
DIV32–SA
M7571–PA
5.5
0.00
35.4
3.5
1.0
DPV11–SA
M8020–PA
1.20
0.30
9.60
1.0
1.0
DRQ3B–SA
M7658–PA
4.50
0.00
22.50
2.0
0.5
DRV1J–SA
M8049–PA
1.80
0.00
9.00
2.0
1.0
DRV1W–SA
M7651–PA
1.80
0.00
9.00
2.0
1.0
DSV11–SA
M3108
5.43
0.69
35.43
3.9
1.0
DTC05–SA
H36041
M
4.0
0.0
15.80
3.6
0.75
1.70
0.50
14.50
–
–
IBQ01–SA
M3125–PA
5.00
0.30
28.60
4.6
1.0
IEQ11–SA
M8634–PA
3.50
0.00
17.50
2.0
1.0
KA675–CA
L4002–CA
4.80
1.60
53.8
4.0
1.0
KA680–BA
L4002–BA
4.80
1.60
53.8
4.0
1.0
KA680–AA
L4002–AA
4.80
1.60
53.8
4.0
1.0
KDA50–SE
M7164
6.93
0.00
34.65
3.0
0.5
—–
M7165
6.57
0.03
33.21
–
–
KFQSA–SA/SE
M7769
5.50
0.00
27.50
4.4
0.5
KLESI–SA/SF
M7740–PA
4.00
0.00
20.00
0.5
1.0
KRQ50–SA/SF
M7552
2.70
0.00
13.50
2.7
1.0
KWV11–SA
M4002–PA
2.20
0.013
11.156
1.0
0.3
KXJ11–SF
M7616
6.0
0.4
46.8
2.0
1.0
KZQSA–SA
M5976
5.4
0.0
27.0
4.4
0.5
LPV11–SA
M8086–PA
2.80
0.00
14.00
1.8
0.5
M9404–PA
M9404
–
0.00
0.0
–
–
M9405–PA
M9405
–
0.00
0.0
–
–
MRV11–D
M8578
1.602
0.00
8.00
3.0
0.5
1 Also
–
include –12 Vdc @ 0.25 A, 3 W.
is for the unpopulated module only.
2 Value
3–12 KA675/KA680/KA690 CPU System Maintenance
Table 3–2 (Cont.): Power Requirements
Current (Amps)
Max
Power
Max
Bus
Loads
Option
Module
+5 V
+12 V
Watts
MS690–BA
L4004–BA
5.03
0.00
26.5
AC
–
DC
–
MS690–CA
L4004–CA
4.2
0.00
21.0
–
–
MS690–DA
L4004–DA
6.4
0.00
32.0
–
–
RF31E–AA/AF
–
1.2
2.21
32.52
N/A
N/A
RF31F–AA/AF
–
1.2
2.21
32.52
N/A
N/A
RF35E–AA/AF
–
0.71
2.29
31.1
N/A
N/A
RF352–AA/AF
–
1.69
5.10
33.0
N/A
N/A
RF71E–AA/AF
–
1.25
1.64
25.93
N/A
N/A
RF72E–AA/AF
–
1.20
1.75
27.00
N/A
N/A
RF73E–AA/AF
–
1.20
1.75
27.00
N/A
N/A
TF85E–JA/JF
–
1.50
2.40
36.30
N/A
N/A
TK50E–AA
–
1.50
2.40
36.30
N/A
N/A
TK70E–AA/AF
–
1.50
2.40
36.30
N/A
N/A
TLZ04–JA/JF
–
1.5
2.4
36.3
N/A
N/A
TQK50–SA/SF
M7546
2.9
0.00
14.5
2.8
0.5
TQK70–SA/SF
M7559
3.50
0.00
17.50
4.3
0.5
TSV05–SA
M7530
6.50
0.00
32.50
1.5
1.0
VCB02–A
M7615
4.60
0.10
24.2
3.5
1.0
VCB02–B
M7168–00
M7169
8.85
0.47
49.89
3.5
1.0
VCB02–C
(2) M7168–00
M7169
12.0
0.47
65.64
3.5
1.0
3.6 DSSI VAXclusters
A DSSI VAXcluster configuration is one in which up to three systems can
access the same DSSI devices. Some failures of any system can be tolerated,
in which case the remaining system(s) continues to access all available DSSI
devices and assure continued processing.
System Setup and Configuration
3–13
Figure 3–5: DSSI Cabling for a Generic Two-System DSSI VAXcluster
Configuration
SYS0
RFxx
RFxx
SYS1
RFxx
RFxx
RFxx
RFxx
DSSI
Boot
Node #2
Boot
Node #1
Ethernet
Satellite
Node
Satellite
Node
LAT
Satellite
Node
LAT
MLO-003295
If one of the CPU modules fails, all satellite nodes booted through that
CPU module lose connections to the system disk. However, the DSSI
VAXcluster enables each satellite node to know that the system disk is still
available through a different path—that of the functioning CPU module. A
connection through that CPU is then established, and the satellite nodes
are able to continue operation. The entire cluster will run slower, since
one CPU is now serving the satellite nodes of both systems. Processing can
continue, however, until Customer Services can repair the problem.
A DSSI VAXcluster system cannot recover from the following conditions:
•
System disk failure, which can be caused by such factors as a power
supply failure in the enclosure containing the disk.
•
DSSI cabling failure, which must be repaired to continue operation.
3–14 KA675/KA680/KA690 CPU System Maintenance
3.6.1 DSSI VAXcluster Configuration Rules
1. An Ethernet (NI)/FDDI is required on all CPU nodes.
2. A DECnet license is required (At least one full function license).
3. At least one common (primary) DSSI bus is required to connect with a
system disk containing system critical files.
4. VAXcluster and VMS license is required.
5. A maximum of eight nodes per DSSI bus:
a. Each adapter or ISE (disk/tape) counts as one node.
b. A DSSI bus is a collection of all DSSI cable/path segments (inside
and outside of cabinets) between two end terminators.
c.
Each node must have a unique bus node ID number (0–7).
6. A maximum of three CPUs/adapters per DSSI bus is supported.
7. The DSSI bus MUST be terminated at both ends.
8. The DSSI bus MUST have a common ground between all elements
(CPU, disks).
a. The ground offset MUST be LESS THAN 200 mV peak-peak.
b. A Number 6 ground strap must be used between enclosures.
9. Maximum DSSI bus length (terminator to terminator):
a. Computer Room: 25m (82 ft) and ground offset < 30 mV peak peak.
b. Office: 20m (65 ft) and ground offset < 200 mV peak - peak.
10. Maximum single cable length is 7.5m (25 ft) between connectors.
11. Disconnecting the DSSI cables is NOT allowed while bus is operational.
12. Number of DSSI busses per CPU:
CPU
DSSI Busses
KA640
1 Embedded DSSI Adapter (EDA), 2 KFQSA on Q–bus
KA660
1 Embedded DSSI Adapter (EDA), 2 KFQSA on Q–bus
System Setup and Configuration
3–15
CPU
DSSI Busses
KA670
2 Embedded DSSI Adapters (EDAs), 2 KFQSA on Q–bus
KA675
2 Embedded DSSI Adapters (EDAs), 2 KFQSA on Q–bus
KA680
2 Embedded DSSI Adapters (EDAs), 2 KFQSA on Q–bus
KA690
2 Embedded DSSI Adapters (EDAs), 2 KFQSA on Q–bus
KA650/KA655
2 KFQSAs on Q–bus
KA630
2 KFQSAs on Q–bus
6xxx
6 KFMSAs per system
9000
6 KFMSAs per XMI
12 KFMSAs per system
13. The minimum VMS revision for DSSI VAXcluster of more than two
nodes with:
a. VAX 4000 Model 300 is VMS 5.4-3
b. VAX 4000 Model 500 is VMS 5.5
c.
VAX 6000 Model 600 is VMS 5.5
14. These rules apply to Digital supplied hardware.
Third party
devices may not conform to DSSI electrical specification requirements.
Therefore, bus length, ground offset, basic noise margining, and warm
swap characteristics are at risk when using third party devices.
15. Like adapters should be connected together whenever possible.
16. Like CPUs should be connected together whenever possible.
For more information on DSSI VAXcluster configurations, refer to the
DSSI VAXcluster Installation and Troubleshooting manual. Figure 3–6
and Figure 3–7 show two popular DSSI VAXcluster configurations using
the VAX 4000 Model 500 system.
3–16 KA675/KA680/KA690 CPU System Maintenance
Figure 3–6: Two-System DSSI VAXcluster
System A
Ststem B
3 2 1
0
2 1 0
5
6 6
7 7
DSSI Cables
Shared DSSI Busses and Devices
Dssi Terminator Locations
System A
DSSI
Adaptor 1
DSSI
Adaptor 0
SHAC
Bus Node 6
System B
KA680
KA680
SHAC
Bus Node 6
SHAC
Bus Node 7
2
1
0
5
0
1
2
3
DSSI
Adaptor 0
DSSI
Adaptor1
SHAC
Bus Node 7
DSSI Bus Nodes for Storage Devices in System B
DSSI Bus Nodes for Storage Devices in System A
MLO-008312
System Setup and Configuration
3–17
Figure 3–7: Expanded Two-System DSSI VAXcluster
System
Expander
2 1 0
3 2 1
0
6 5 4
System
5 4 3
DSSI Terminator Locations
MLO-004242
3.7 Firmware Commands and Utilities Used in
System Configuration
Several commands and utilities are needed to configure a system. This
section covers commands for examining and setting system parameters,
DSSI parameters, and module addresses. For a complete listing of firmware
commands, refer to Appendix A.
3.7.1 Examining System Configuration
Several variations of the SHOW command provide a display of options and
key configuration information.
3–18 KA675/KA680/KA690 CPU System Maintenance
•
SHOW DEVICE — Lists devices (mass storage, Ethernet, and Q–bus) in
the system. (The SHOW DEVICE command combines the information
displayed using the SHOW command with DSSI, UQSSP, SCSI, and
Ethernet.)
•
SHOW DSSI — Lists all DSSI devices and their associated DSSI
parameters for embedded DSSI adapters.
•
SHOW ETHERNET — Lists the hardware Ethernet address for each
Ethernet adapter.
•
SHOW QBUS — Lists all Q–bus devices and their I/O addresses in hex,
the address as it would appear in the Q-Bus I/O space in octal, and well
as the word data read in hex.
•
SHOW SCSI — Lists all SCSI devices in the system.
•
SHOW UQSSP — Lists all DSSI devices for KFQSA-based DSSI
adapters.
•
SHOW MEMORY — Lists main memory configuration for each memory
board.
Sample displays of each of the above commands are provided below.
>>>SHOW DEVICE
DSSI Bus 0 Node 0 (CLYDE)
-DIA0 (RF73)
DSSI Bus 0 Node 1 (BONNIE)
-DIA1 (RF73)
DSSI Bus 0 Node 5 (TFDR1)
-MIA5 (TF85)
DSSI Bus 0 Node 6 (*)
DSSI Bus 1 Node 7 (*)
UQSSP Disk Controller 0 (772150)
-DUA20 (RF31)
UQSSP Disk Controller 1 (760334)
-DUB21 (RF31)
UQSSP Disk Controller 2 (760340)
-DUC22 (RF31)
UQSSP Disk Controller 3 (760322)
-DUD23 (RF31)
UQSSP Tape Controller 0 (774500)
-MUA0 (TK70)
SCSI Adaptor 0 (761400), SCSI ID 7
-MKA0 (DEC TLZ04 1991(c)DEC)
Ethernet Adapter
-EZA0 (08-00-2B-06-10-42)
>>>SHOW DSSI
DSSI Bus 0 Node 0 (CLYDE)
System Setup and Configuration
3–19
-DIA0 (RF73)
DSSI Bus 0 Node
-DIA1 (RF73)
DSSI Bus 0 Node
-MIA5 (TF85)
DSSI Bus 0 Node
DSSI Bus 1 Node
>>>
1 (BONNIE)
5 (TFDR1)
6 (*)
7 (*)
>>>SHOW ETHERNET
Ethernet Adapter
-EZA0 (08-00-2B-0B-29-14)
>>>SHOW UQSSP
UQSSP Disk Controller
-DUA20 (RF31)
UQSSP Disk Controller
-DUB21 (RF31)
UQSSP Disk Controller
-DUC22 (RF31)
UQSSP Disk Controller
-DUD23 (RF31)
UQSSP Tape Controller
-MUA0 (TK70)
0 (772150)
1 (760334)
2 (760340)
3 (760322)
0 (774500)
>>SHOW QBUS
Scan of Q-bus I/O Space
-20001920 (774440) = FF08 DELQA/DESQA
-20001922 (774442) = FF00
-20001924 (774444) = FF2B
-20001926 (774446) = FF08
-20001928 (774450) = FFD7
-2000192A (774452) = FF41
-2000192C (774454) = 0000
-2000192E (774456) = 1030
-20001F40 (777500) = 0020 IPCR
Scan of Q-bus Memory Space
>>>SHOW SCSI
SCSI Adapter 0 (761300), SCSI ID 7
-MKA500 (DEC TLZ04 1991 (c) DEC)
>>>SHOW MEMORY
Memory 0: 00000000 to 01FFFFFF, 32 Mbytes, 0 bad pages
Total of 32 Mbytes, 0 bad pages, 112 reserved pages
3–20 KA675/KA680/KA690 CPU System Maintenance
3.7.2 Using the CONFIGURE Command to Determine CSR
Addresses for Q-Bus Modules
Each Q–bus module in a system must use a unique device address and
interrupt vector. The device address is also known as the control and
status register (CSR) address. Most modules have switches or jumpers for
setting the CSR address values. The value of a floating address depends
on what other modules are housed in the system. The CONFIGURE is
used to determine what the proper CSR addresses should be for the given
configuration. You can than configure the Q–bus modules according to this
information.
NOTE: These recommended values simplify the use of the MDM diagnostic
package and are compatible with VMS device drivers. You can select
nonstandard addresses, but they require a special setup for use with VMS
drivers and MDM. See the MicroVAX Diagnostic Monitor User’s Guide for
information about the CONNECT and IGNORE commands, which are used
to set up MDM for testing nonstandard configurations.
Determine CSR addresses values for a module as follows:
1. Use the SHOW QBUS firmware command to get a listing of the Q–bus
modules currently in the system.
2. Determine the correct values for the module using the CONFIGURE
firmware command command. The CONFIG utility eliminates the need
to boot the VMS operating system to determine CSRs and interrupt
vectors. Enter the CONFIGURE command, then HELP for the list
of supported devices. Enter the device and number of devices for all
existing modules in the system, as well as for those devices you are
adding.
>>>CONFIGURE
Enter device configuration, HELP, or EXIT
Device, Number? help
Devices:
System Setup and Configuration
3–21
Devices:
LPV11
KXJ11
RLV12
TSV05
DMV11
DELQA
RRD50
RQC25
RV20
KFQSA-TAPE
CXA16
CXB16
LNV21
QPSS
KWV11C
ADV11D
DRQ3B
VSV21
IDV11D
IAV11A
DESNA
IGQ11
KWV32
KZQSA
Device,Number?
Numbers:
1 to 255, default is 1
Device,Number? cxa16,1
Device,Number? desqa,1
Device,Number? tqk70
Device,Number? qza
Device,Number? kfqsa-disk
Device,Number? exit
DLV11J
RXV21
DEQNA
KFQSA-DISK
KMV11
CXY08
DSV11
AAV11D
IBQ01
IAV11B
DIV32
M7577
DZQ11
DRV11W
DESQA
TQK50
IEQ11
VCB01
ADV11C
VCB02
IDV11A
MIRA
KIV32
LNV24
DZV11
DRV11B
RQDX3
TQK70
DHQ11
QVSS
AAV11C
QDSS
IDV11B
ADQ32
DTCN5
M7576
Address/Vector Assignments
-774440/120 DESQA
-772150/154 KFQSA-DISK
-774500/260 TQK70
-760440/300 CXA16
-761300/310 KZQSA
NOTE: Of the devices listed in the CONFIG display, not all are
supported on the VAX 4000 Model 500 systems. See Section 3.2 for
supported options.
The LPV11–SA has two sets of CSR address and interrupt vectors. To
determine the correct values for an LPV11–SA, enter LPV11,2 at the
DEVICE prompt for one LPV11–SA or enter LPV11,4 for two LPV11–SA
modules.
3. See the Microsystems Options manual for switch and CSR and interrupt
vector jumper settings for supported options.
NOTE: The CSR address for KFQSA storage adapter is programmed
using firmware commands. Refer to the apph for using the SET/HOST
/UQSSP/MAINT command to access the Diagnostic Utility Program
(DUP) driver utility to configure the CSRs for the KFQSA module.
3–22 KA675/KA680/KA690 CPU System Maintenance
DFA01
DPV11
KDA50
TU81E
DHV11
LNV11
AXV11C
DRV11J
IDV11C
DTC04
DTC05
DEQRA
3.7.3 Setting and Examining Parameters for DSSI Devices
Two types of DSSI storage adapters are available for VAX 4000 systems: an
embedded DSSI adapter, which is part of the CPU, and the KFQSA adapter.
The KA675/KA680/KA690 CPU has two embedded DSSI adapters: Bus 0
and Bus 1.
Each adapter provides a separate DSSI bus that can support up to eight
nodes, where the adapter and each DSSI storage devices count as one node,
hence each DSSI adapter can support up to seven DSSI storage devices (six
DSSI storage devices for a two-system DSSI VAXcluster; five DSSI storage
devices for a three-system DSSI VAXcluster configuration). The adapters
make a connection between the CPU and the requested device on their
respective DSSI bus. Each DSSI device has its own controller and server
that contain the intelligence and logic necessary to control data transfers
over the DSSI bus.
3.7.3.1 DSSI Device Parameters
Six principal parameters are associated with each DSSI device:
•
Bus Node ID
•
ALLCLASS
•
UNITNUM
•
FORCEUNI
•
NODENAME
•
SYSTEMID
NOTE: Each of the above parameters, with the exception of the bus node
ID, are programmed and examined using the console-based Diagnostic
and Utility Program (DUP) driver utility. The bus node ID is physically
determined by the numbered bus node ID plug that inserts into the device’s
front panel.
A brief description of each parameter follows:
The bus node ID parameter is provided by the bus node ID plug on
the device’s front panel. Each DSSI bus can support up to eight nodes,
0–7. Each DSSI adapter and each device count as a node. Hence,
in a single-system configuration, a DSSI bus can support up to seven
devices, bus nodes 0–6 (with node 7 reserved for the adapter); in a twosystem DSSI VAXcluster configuration, up to six devices, 0–5 (with nodes
6 and 7 reserved for the adapters); in a three-system DSSI VAXcluster
System Setup and Configuration
3–23
configuration, up to five devices, 0–4 (with nodes 5, 6, and 7 reserved for
the adapters).
The ALLCLASS parameter determines the device allocation class. The
allocation class is a numeric value from 0 to 255 that is used by the VMS
operating system to derive a path-independent name for multiple access
paths to the same device. The ALLCLASS firmware parameter corresponds
to the VMS SYSGEN parameter ALLOCLASS.
DSSI devices are shipped from the factory with a default allocation class of
zero. Each device to be served to a cluster must have a nonzero
allocation class that matches the allocation class of the system.
Refer to the VMS VAXcluster manual for rules on specifying allocation class
values.
The UNITNUM parameter determines the unit number of the device. By
default, the device unit number is supplied by the bus node ID plug on the
device’s front panel. Systems with multiple DSSI busses, as described
later in this section, require that the default values be replaced
with unique unit numbers. To set unit numbers and override the default
values, you use the console-based DUP driver utility to supply values to
the UNITNUM parameter and to set a value of zero to device parameter
FORCEUNI.
The FORCEUNI parameter controls the use of UNITNUM to override the
default device unit number supplied by the bus node ID plug. When
FORCEUNI is set to a value of 0, the operating system uses the value
assigned to the UNITNUM parameter; when FORCEUNI is set to a value
of 1, the operating system uses the value supplied by the bus node ID plug.
The NODENAME parameter allows each device to have an alphanumeric
node name of up to eight characters. DSSI devices are shipped from the
factory with a unique identifier, such as R7CZZC, R7ALUC, and so on. You
can provide your own node name.
The SYSTEMID parameter provides a number that uniquely identifies the
device to the operating system. This parameter may need to be modified
only when replacing a device.
3.7.3.2 How VMS Uses the DSSI Device Parameters
This section describes how the operating system uses the parameters to
form unique identifiers for each device. Configurations that require you to
assign new unit numbers for devices are also described.
With an allocation class of zero, the operating system can use the default
parameter values to provide each device with a unique device name. The
operating system uses the node name along with the device logical name
in the following manner:
3–24 KA675/KA680/KA690 CPU System Maintenance
NODENAME$DIAu
where:
NODENAME is a unique node name and u is the unit number.
With a nonzero allocation class, the operating system relies on unit number
values to create a unique device name. The operating system uses the
allocation class along with the device logical name in the following manner:
$ALLCLASS$DIAu
where:
ALLCLASS is the allocation class for the system and devices, and u is a
unique unit number.
Using mass storage expanders, you can fill multiple DSSI busses: busses 0
and 1 supplied by the CPU module, and a third and fourth DSSI bus using
two KFQSA adapters. Each bus can have up to seven DSSI devices (bus
nodes 0–6). When more than one bus is being used, and your system is
using a nonzero allocation class, you need to assign new unit numbers for
devices on all but one of the DSSI busses, since the unit numbers for all
DSSI storage devices connected to a system’s associated DSSI busses must
be unique.
Figure 3–8 illustrates the need to program unit numbers for a system using
more than one DSSI bus and a nonzero allocation class. In the case of the
nonzero allocation class, the operating system sees three of the ISEs as
having duplicate device names, which is an error, as all unit numbers must
be unique.
System Setup and Configuration
3–25
Figure 3–8: VMS Operating System Requires Unique Unit Numbers for
DSSI Devices
Allocation Class=0
Nonzero Allocation Class
(Example: ALLCLASS=1)
R7BUCC$DIA0
$1$DIA0
R7CZZC$DIA1
$1$DIA1
R7ALUC$DIA2
$1$DIA2
R7EB3C$DIA3
$1$DIA3
TFDR1$MIA5
$1$MIA5
R7IDFC$DIA0
$1$DIA0
R7IBZC$DIA1
$1$DIA1
R7IKJC$DIA2
$1$DIA2
R7ID3C$DIA3
$1$DIA3
R7XA4C$DIA4
$1$DIA4
R7QIYC$DIA5
$1$DIA5
R7DA4C$DIA6
$1$DIA6
* Duplicate 0
* Duplicate 1
* Duplicate 2
* Duplicate 3
* Nonzero allocation class examples with an asterisk indicate duplicate device names.
For one of the DSSI busses, the unit numbers need to be reprogrammed to avoid this error.
MLO-007176
NOTE: Digital recommends configuring systems to have unique unit
numbers even for standalone systems using an allocation class of zero. This
practice will avoid problems with duplicate device names if the system is
later configured in a cluster.
The following instructions describe how to change DSSI parameters, using
the DUP driver utility. In the example procedures, the allocation class will
be set to 1, the devices for Bus 0 (in the VAX 4000) will be assigned new unit
numbers (to avoid the problem of duplicate unit numbers), and the system
disk will be assigned a new node name. To examine DSSI parameters from
the VMS operating system, refer to Section 3.7.3.4.
3–26 KA675/KA680/KA690 CPU System Maintenance
Figure 3–9 shows sample DSSI busses and bus node IDs for an expanded
VAX 4000 Model 500 system.
Figure 3–9: Sample DSSI Busses for an Expanded VAX 4000 Model 500
System
System
Expander
2 1 0
5
3 2 1
0
6 5 4
7 7
Bus 0
DSSI Cable
Bus 1
Dssi Terminator Locations
MLO-008628
1. Enter the console mode.
The procedure for programming parameters for DSSI devices from
console mode requires that you issue commands to those devices at
the console prompt (>>>). You may enter these commands in either
uppercase or lowercase letters. Unless otherwise instructed, enter each
command, then press Return.
Enter console mode as follows:
a. Set the Break Enable/Disable switch on the system console module
to the enable position (up, position 1).
b. Set the Power switch for each unit (each system in a DSSI
VAXcluster configuration, and any expanders for expanded systems)
to on (1).
System Setup and Configuration
3–27
Wait for the system to display the console prompt (>>>).
2. To display the DSSI devices on embedded DSSI busses, enter SHOW
DSSI at the console prompt. To display the DSSI devices on KFQSAbased DSSI busses, enter SHOW UQSSP.
The firmware displays two lines of information for each device. For
embedded DSSI, the firmware displays the following:
•
The first line contains the bus number, node number, and node
name.
•
The second line contains the device name and unit number followed
by the device type in parentheses.
For embedded DSSI, the device name consists of the letters DIAu or
DIBu (MIAu or MIBu for the TF85 tape drive)—devices on bus 0 are
listed as DIA, devices on bus 1 are listed as DIB—and u is a unique
unit number. The embedded DSSI adapter for each bus is identified by
an asterisk (*).
The embedded DSSI display for Example 3–1 shows a system with four
DSSI devices (unit numbers 0–3) and an R400X expander with seven
DSSI devices (unit numbers 0–6).
3–28 KA675/KA680/KA690 CPU System Maintenance
Example 3–1: SHOW DSSI Display (Embedded DSSI)
>>>SHOW DSSI
DSSI Bus 0 Node
-DIA0 (RF31)
DSSI Bus 0 Node
-DIA1 (RF31)
DSSI Bus 0 Node
-DIA2 (RF31)
DSSI Bus 0 Node
-MIA5 (TF85)
DSSI Bus 0 Node
DSSI Bus 1 Node
-DIB0 (RF31)
DSSI Bus 1 Node
-DIB1 (RF31)
DSSI Bus 1 Node
-DIB2 (RF31)
DSSI Bus 1 Node
-DIB3 (RF31)
DSSI Bus 1 Node
-DIB4 (RF31)
DSSI Bus 1 Node
-DIB5 (RF31)
DSSI Bus 1 Node
-DIB6 (RF31)
DSSI Bus 1 Node
>>>
0 (R7ALUC)
1 (R7EB3C)
2 (R7EB22)
5 (TFDR1)
6 (*)
0 (SNEEZY)
1 (DOPEY)
2 (SLEEPY)
3 (GRUMPY)
4 (BASHFUL)
5 (HAPPY)
6 (DOC)
7 (*)
For KFQSA-based DSSI, the firmware displays the following:
•
The first line contains the UQSSP disk controller number and device
node name.
•
The second line contains the device name and unit number followed by
the device type in parentheses.
For KFQSA-based DSSI, the device name consists of the letters DUcu,
where c is the controller letter, and u is a unique unit number.
System Setup and Configuration
3–29
Example 3–2 shows a sample KFQSA-based DSSI bus.
Example 3–2: SHOW UQSSP Display (KFQSA-Based DSSI)
>>>SHOW UQSSP
UQSSP Disk Controller
-DUA0 (RF31)
UQSSP Disk Controller
-DUB1 (RF31)
UQSSP Disk Controller
-DUC2 (RF31)
UQSSP Disk Controller
-DUD3 (RF31)
UQSSP Tape Controller
-MUA0 (TK70)
0 (772150)
1 (760334)
2 (760340)
3 (760322)
0 (774500)
For the examples in this section, each device will be assigned an allocation
class of 1, and the system disk will be given a new node name. Also,
devices DIA0, DIA1, and DIA2; and DUA0, DUB1, DUC2, and DUD3 will
be assigned new unit numbers.
NOTE: The DUP server examples throughout this section are for RF-series
ISEs. The displays for the TF85 tape drive differ slightly from the RF-series
displays.
3.7.3.3 Entering the DUP Driver Utility from Console Mode
To examine and change DSSI parameters, you must first activate the DUP
driver utility by setting host to the specific device for which you want to
modify or examine parameters.
Use the following command for embedded DSSI:
SET HOST/DUP/DSSI/BUS:<bus_number> <node_number> PARAMS
where:
<bus_number> is the DSSI bus number (0 or 1), and <node_number> is the
bus node ID (0–6) for the device on the bus.
Use the following command for KFQSA-based DSSI:
SET HOST/DUP/UQSSP/DISK <controller_number> PARAMS
where:
<controller_number> is the controller number (provided by the SHOW
UQSSP display) for the device on the bus.
3–30 KA675/KA680/KA690 CPU System Maintenance
In Example 3–3, SET HOST/DUP/DSSI/BUS:1 0 PARAMS is entered to start the
DUP server for the ISE at node 0 of embedded DSSI bus 1. In Example 3–4,
SET HOST/DUP/UQSSP/DISK 0 PARAMS is entered to start the DUP server for
the ISE at controller 0 of a KFQSA-based DSSI bus.
Example 3–3: Accessing the DUP Driver Utility From Console Mode
(Embedded DSSI)
>>>SET HOST/DUP/DSSI/BUS:1 0 PARAMS
Starting DUP server...
Copyright (c) 1991 Digital Equipment Corporation
PARAMS>
Example 3–4: Accessing the DUP Driver Utility From Console Mode
(KFQSA-Based DSSI)
>>>SET HOST/DUP/UQSSP/DISK 0 PARAMS
Starting DUP server...
Copyright (c) 1991 Digital Equipment Corporation
PARAMS>
3.7.3.4 Entering the DUP Driver Utility from VMS
To examine and change DSSI parameters, you must first access the DUP
driver utility by setting host to the specific device for which you want to
modify or examine parameters.
To access the DUP driver from VMS:
a. Connect to the Diagnostic and Utility Program (DUP) and load its driver
using the VMS System Generation Utility (SYSGEN) as shown below:
$ MCR SYSGEN
SYSGEN> CONNECT/NOADAPTER FYA0
SYSGEN> EXIT
$
b. Access the DUP driver by setting host to the specific device you want
to write protect. Use the following command:
SET HOST/DUP/SERVER=MSCP$DUP/TASK=PARAMS <node_name>
System Setup and Configuration
3–31
where:
<node_name> is the device node name (the node name, in parenthesis,
is listed using the VMS DCL command SHOW DEVICE DI).
In Example 3–5, SET HOST/DUP/SERVER-MSCP$DUP/TASK=PARAMS R35F3C is
entered to start the DUP server for the ISE with a nodename of R35F3C.
Example 3–5: Accessing the DUP Driver Utility From VMS
$ MCR SYSGEN
SYSGEN> CONNECT/NOADAPTER FYA0
SYSGEN> EXIT
$ SET HOST/DUP/SERVER=MSCP$DUP/TASK=PARAMS R35F3C
Starting DUP server...
Copyright (c) 1992 Digital Equipment Corporation
PARAMS>
3.7.3.5 Setting Allocation Class
After entering the DUP driver utility for a specified device, you can examine
and set the allocation class for the device as follows:
NOTE: The ALLCLASS parameter should only be set through console mode.
Setting the ALLCLASS parameter from VMS is not recommended.
1. At the PARAMS> prompt, enter SHOW ALLCLASS to check the allocation
class of the ISE to which you are currently connected.
2. Enter SET ALLCLASS 1 (or enter the allocation class you desire).
3. Enter SHOW ALLCLASS to verify the new allocation class.
3–32 KA675/KA680/KA690 CPU System Maintenance
Example 3–6 shows the steps for examining and changing the allocation
class for a specified device. In the example, the allocation class is changed
from an allocation class of 0 to an allocation class of 1.
Example 3–6: Setting Allocation Class for a Specified Device
PARAMS>SHOW ALLCLASS
Parameter
Current
--------- ---------------ALLCLASS
0
Default
---------------0
Type
-------Byte
Radix
----Dec
B
Default
---------------0
Type
-------Byte
Radix
----Dec
B
PARAMS>SET ALLCLASS 1
PARAMS>SHOW ALLCLASS
Parameter
Current
--------- ---------------ALLCLASS
1
3.7.3.6 Setting Unit Number
After entering the DUP driver utility for a specified device, you can examine
and set the unit number for the device as follows:
1. At the PARAMS> prompt, enter SHOW UNITNUM to check the unit number
of the ISE to which you are currently connected.
2. Enter SET UNITNUM 10 (or enter the unit number you desire).
3. Enter SET FORCEUNI 0 to override the default unit number value
supplied by the bus node ID plug.
4. Enter SHOW UNITNUM to verify the new unit number.
5. Enter SHOW FORCEUNI to verify that the current value for the FORCEUNI
parameter is 0.
Example 3–7 shows the steps for changing the unit number of a
specified device from unit number 0 to unit number 10.
6. Label the device with its unit number, using the unit number labels
shipped with your system. Figure 3–10 shows where to affix a unit
number label on the device front panel.
System Setup and Configuration
3–33
Example 3–7: Setting a Unit Number for a Specified Device
PARAMS>SHOW UNITNUM
Parameter
Current
--------- ---------------UNITNUM
0
Default
---------------0
Type
-------Word
Radix
----Dec
U
Parameter
Current
--------- ---------------UNITNUM
10
Default
---------------0
Type
-------Word
Radix
----Dec
U
PARAMS>SHOW FORCEUNI
Parameter
Current
--------- ---------------FORCEUNI
0
Default
---------------1
Type
-------Boolean
Radix
----0/1
U
PARAMS>SET UNITNUM 10
PARAMS>SET FORCEUNI 0
PARAMS>SHOW UNITNUM
3–34 KA675/KA680/KA690 CPU System Maintenance
Figure 3–10: Attaching a MSCP Unit Number Label to the Device Front
Panel
RF30/70-Series ISE
Attach Unit
Number Label
RF35 ISE
11
10
1
10
0
0
TF85
Attach Unit
Number Label
15
85
ad
lo
Un
To
Re Han Op
P
W
Un
ait res
d e
m
lo
s
ov le n t
ad
his
e
Lig But
Ta
to
ht
pe
n
To
H
Ha C
O
Lo
nd los Inse and pe Wa
it
ad
le n
le e
r
th
th t Ta
Lig
is
is
pe
ht
Ta
TF
W
rit
Pr e
ot
ec
te
d
pe
in
Us
Us
e
e
Cle
Ta anin
pe g
O
pe
Ha rat
nd e
le
Attach Unit
Number Labels
5
MLO-007178
System Setup and Configuration
3–35
3.7.3.7 Setting Node Name
After entering the DUP driver utility for a specified device, you can examine
and set the node name for the device as follows:
1. At the PARAMS> prompt, enter SHOW NODENAME to check the node name of
the ISE to which you are currently connected.
2. Enter SET NODENAME SYSDSK (or enter the desired alphanumeric node
name of up to eight characters).
3. Enter SHOW NODENAME to verify the new node name.
Example 3–8 shows the steps for changing the node name of a specified
device from the factory-supplied name to SYSDSK.
Example 3–8: Changing a Node Name for a Specified Device
PARAMS>SHOW NODENAME
Parameter
Current
--------- ---------------NODENAME
R7CZZC
Default
---------------RF31
Type
-------String
Radix
----Ascii
B
Default
---------------RF31
Type
-------String
Radix
----Ascii
B
PARAMS>SET NODENAME SYSDSK
PARAMS>SHOW NODENAME
Parameter
Current
--------- ---------------NODENAME
SYSDSK
3.7.3.8 Setting System ID
NOTE: This parameter is modified only when replacing a device. All
parameters for the replacement device should be programmed to match those
of the original device.
After entering the DUP driver utility for a specified device, you can examine
and set the system ID for the device as follows:
1. At the PARAMS> prompt, enter SHOW SYSTEMID to check the system ID of
the device to which you are currently connected.
2. Enter SET SYSTEMID System ID (enter the desired serial number-based
system ID).
3. Enter SHOW SYSTEMID to verify the new system ID.
3–36 KA675/KA680/KA690 CPU System Maintenance
Example 3–9 shows the steps for changing the system ID of a specified
device from the factory-supplied system ID to 1402193310841 (the system
ID for the replacement device is programmed to match that of the original).
Example 3–9: Changing a System ID for a Specified Device
PARAMS>SHOW SYSTEMID
Parameter
Current
--------- ---------------SYSTEMID
0402193310841
Default
---------------0000000000000
Type
-------Quadword
Radix
----Hex
B
Type
-------Quadword
Radix
----Hex
B
PARAMS>SET SYSTEMID 1402193310841
PARAMS>SHOW SYSTEMID
Parameter
Current
--------- ---------------SYSTEMID
1402193310841
Default
---------------0000000000000
3.7.3.9 Exiting the DUP Driver Utility
After you have completed setting and examining DSSI device parameters,
enter the WRITE command at the PARAMS> prompt to save the device
parameters you have changed using the SET command. The changes are
recorded to nonvolatile memory.
If you have changed the allocation class or node name of a device, the DUP
driver utility will ask you to initialize the controller. Answer Yes (Y) to
allow the changes to be recorded and to exit the DUP driver utility.
If you have not changed the allocation class or node name, enter the EXIT
command at the PARAMS> prompt to exit the DUP driver utility for the
specified device. Example 3–10 shows the procedure for saving parameter
changes. In the example, the controller is initialized.
System Setup and Configuration
3–37
Example 3–10: Exiting the DUP Driver Utility for a Specified Device
PARAMS>WRITE
Changes require controller initialization, ok? [Y/(N)] Y
Stopping DUP server...
>>>
NOTE: You must repeat the procedures in this section for each device for
which you want to change parameters.
Example 3–11 shows the DSSI busses for the embedded DSSI adapters after
the unit numbers for the disk devices on bus 0 have been changed from 0,
1, and 2 to 10, 11, and 12 (by adding 10 to the bus node ID number, the
unit number’s least significant digit will still correspond to the number on
the bus node ID plug). Note that the bus 0 device names are now DIA10,
DIA11, and DIA12.
Example 3–11: SHOW DSSI Display
>>>SHOW DSSI
DSSI Bus 0 Node
-DIA10 (RF31)
DSSI Bus 0 Node
-DIA11 (RF31)
DSSI Bus 0 Node
-DIA12 (RF31)
DSSI Bus 0 Node
-MIA5 (TF85)
DSSI Bus 0 Node
DSSI Bus 1 Node
-DIB0 (RF31)
DSSI Bus 1 Node
-DIB1 (RF31)
DSSI Bus 1 Node
-DIB2 (RF31)
DSSI Bus 1 Node
-DIB3 (RF31)
DSSI Bus 1 Node
-DIB4 (RF31)
DSSI Bus 1 Node
-DIB5 (RF31)
0 (SYSDSK)
1 (R7EB3C)
2 (R7EB22)
5 (TFDR1)
6 (*)
0 (SNEEZY)
1 (DOPEY)
2 (SLEEPY)
3 (GRUMPY)
4 (BASHFUL)
5 (HAPPY)
Example 3–11 (continued on next page)
3–38 KA675/KA680/KA690 CPU System Maintenance
Example 3–11 (Cont.): SHOW DSSI Display
DSSI Bus 1 Node 6 (DOC)
-DIB6 (RF31)
DSSI Bus 1 Node 7 (*)
>>>
Example 3–12 shows the sample KFQSA-based DSSI bus after the unit
numbers have been changed from 0, 1, 2, and 3 to 20, 21, 22, and 23. Note
that the device names are now DUA20, DUB21, DUC22, and DUD23.
Example 3–12: SHOW UQSSP Display (KFQSA-Based DSSI)
>>>SHOW UQSSP
UQSSP Disk Controller
-DUA20 (RF31)
UQSSP Disk Controller
-DUB21 (RF31)
UQSSP Disk Controller
-DUC22 (RF31)
UQSSP Disk Controller
-DUD23 (RF31)
UQSSP Tape Controller
-MUA0 (TK70)
0 (772150)
1 (760334)
2 (760340)
3 (760322)
0 (774500)
3.7.4 Write-Protecting an RF35 ISE
You may want to write-protect an ISE containing sensitive data you do not
want changed or accidentally erased.
The system disk (the ISE containing system software) and ISEs containing
work areas for users should be write-enabled, the normal operating setting.
For the RF35 ISE, which has no Write-Protect button, you set writeprotection through VMS commands or through firmware commands in
console mode.
3.7.4.1 Software Write-Protect for RF-Series ISEs
Since the RF35 does not have a Write-Protect button, the software writeprotect is the primary method for write-protecting an RF35.
The software write-protect is available through VMS using the MOUNT
utility with the /NOWRITE qualifier.
To software write-protect an ISE, enter the following DCL command from
the VMS operating system.
System Setup and Configuration
3–39
MOUNT <device_name> <volume_label>/SYSTEM/NOWRITE
where:
<device_name> is the device name, as shown using the VMS DCL command
SHOW DEVICE DI, and <volume_label> is the volume label for the device.
For example,
$ MOUNT $1$DIA1 OMEGA/SYSTEM/NOWRITE
will software write-protect device $1$DIA1.
Dismounting, and then remounting the device (without using the
/NOWRITE qualifier), will write-enable the device.
Use the VMS DCL command SHOW DEVICE DI to check the protection
status of the drive. A write-protected drive will show a device status of
‘‘Mounted wrtlck’’. Refer to your VMS documentation for more information
on using the MOUNT Utility.
CAUTION: When you dismount then mount the device again, it will no
longer be write-protected.
3.7.4.2 Hardware Write-Protect For RF35 ISEs
The hardware write-protect provides a more permanent write-protection
than the software write-protect in that, once you hardware write-protect
an RF35, it remains write-protected, regardless of the availability of
the operating system or if the system is powered-down. In addition, a
hardware write-protect cannot be removed using the MOUNT command.
The hardware write-protect simply provides the same degree of writeprotection available to RF-series ISEs that have a Write-Protect button.
You should consider hardware write-protecting an RF35 in the following
situations:
•
If you want to write-protect an RF35 ISE when the VMS operating
system is not available, such as before running the MicroVAX
Diagnostic Monitor (MDM).
•
If you want to ensure that an RF35 remains write-protected, since the
hardware write-protect cannot be removed using the VMS command
MOUNT and will remain in effect even if the operating system is
brought down.
You can hardware write-protect an RF35 from VMS or through firmware
commands entered at the console prompt (>>>). Use the following
instructions:
3–40 KA675/KA680/KA690 CPU System Maintenance
1. Access the Diagnostic and Utility Program (DUP) driver for the device
you want to write-protect.
•
To access the DUP driver from console mode:
a. Enter console mode by pressing the Halt Button or powering up
the system with the Break Enable/Disable switch set to enable
(up, position 1).
CAUTION: Halting your system without following the shutdown
procedure described in your system software manuals may result
in loss of data.
b. Access the DUP driver by setting host to the specific device you
want to write protect.
Use the following command for embedded DSSI:
SET HOST/DUP/DSSI/BUS:<bus_number> <node_number> PARAMS
where:
<bus_number> is the DSSI bus number (0 or 1), and <node_
number> is the bus node ID (0–6) for the device on the bus
(bus number and node number are listed in the SHOW DSSI
display).
Use the following command for KFQSA-based DSSI:
SET HOST/DUP/UQSSP/DISK <controller_number> PARAMS
where:
<controller_number> is the controller number (listed in the
SHOW UQSSP display) for the device on the bus.
•
To access the DUP driver from VMS:
a. Connect to the Diagnostic and Utility Program (DUP) and load
its driver using the VMS System Generation Utility (SYSGEN)
as shown below:
$ MCR SYSGEN
SYSGEN> CONNECT/NOADAPTER FYA0
SYSGEN> EXIT
$
b. Access the DUP driver by setting host to the specific device you
want to write protect. Use the following command:
SET HOST/DUP/SERVER=MSCP$DUP/TASK=PARAMS <node_name>
System Setup and Configuration
3–41
where:
<node_name> is the device node name (the node name, in
parenthesis, is listed in the SHOW DEVICE DI display).
2. At the PARAMS> prompt, enter SET WRT_PROT 1 to write-protect the ISE
to which you are currently connected.
NOTE: To verify that you have set host to the intended drive, you can
enter the command LOCATE at the PARAMS> prompt. The LOCATE
command causes the drive’s Fault indicator to blink momentarily.
3. Enter SHOW WRT_PROT to verify the WRT_PROT parameter is set to 1.
4. After you have completed setting and examining the WRT_PROT device
parameter, enter the WRITE command at the PARAMS> prompt to save
the device parameter. The change is recorded to nonvolatile memory.
5. Enter the EXIT command at the PARAMS> prompt to exit the DUP driver
utility for the specified device.
Example 3–13 provides an example of setting a hardware write-protect
through firmware; Example 3–14 provides an example of setting a hardware
write-protect through VMS.
Example 3–13: Setting Hardware Write-Protection Through Firmware
>>>SET HOST/DUP/DSSI/BUS:0 1 PARAMS
Starting DUP server...
Copyright (c) 1992 Digital Equipment Corporation
PARAMS>SET WRT_PROT 1
PARAMS>WRITE
PARAMS>SHOW WRT_PROT
Parameter
Current
Default
Type
--------- ---------------- ---------------- -------WRT_PROT
1
0
Boolean
PARAMS>EXIT
Exiting...
Stopping DUP server...
>>>
3–42 KA675/KA680/KA690 CPU System Maintenance
Radix
----0/1
Example 3–14: Setting Hardware Write-Protection Through VMS
$ MCR SYSGEN
SYSGEN> CONNECT/NOADAPTER FYA0
SYSGEN> EXIT
$ SET HOST/DUP/SERVER=MSCP$DUP/TASK=PARAMS R35F3C
Starting DUP server...
Copyright (c) 1992 Digital Equipment Corporation
PARAMS>SET WRT_PROT 1
PARAMS>WRITE
PARAMS>SHOW WRT_PROT
Parameter
Current
Default
Type
--------- ---------------- ---------------- -------WRT_PROT
1
0
Boolean
PARAMS>EXIT
Exiting...
Stopping DUP server...
$
Radix
----0/1
To remove the hardware write-protection, repeat the above procedure, only
set the WRT_PROT value to 0.
You can verify that the device is write-protected while running VMS—when
you issue the VMS DCL command SHOW DEVICE DI, a write-protected
drive will show a device status of ‘‘Mounted wrtlck’’. If you issue the VMS
command SHOW DEVICE/FULL, a write-protected drive will be listed as
‘‘software write-locked’’.
NOTE: You cannot remove hardware write-protection using the VMS
MOUNT utility.
3.7.5 Setting System Parameters: Boot Defaults, Bootflags,
Halt and Restart Action
Several firmware commands are used to set and examine system
parameters.
3.7.5.1 Setting the Boot Default
To direct the system to boot automatically from a specific device or to change
the setting of the default boot device, put the system into console mode and
at the >>> prompt, enter ‘‘SET BOOT device-name’’. For example,
>>>SET BOOT EZA0
sets the system default boot device to be the Ethernet controller.
Once you have selected a boot device, the system autoboots from that device
each time you turn it on (provided the Break Enable/Disable switch is set to
System Setup and Configuration
3–43
disable or that a halt action of REBOOT or RESTART_REBOOT has been
defined).
Using ‘‘SET BOOT device-name,device-name,device-name’’, you can also
specify a string of default boot devices (up to 32 characters, with devices
separated by commas and no spaces) for which the system will check for
bootable software. The system checks the devices in the order specified and
boots from the first one that contains bootable software. For example,
>>>SET BOOT DUA0,DIA0,MIA5,EZA0
directs the system to use DUA0, DIA0, MIA5, and EZA0 as the default
boot devices. When the system autoboots, or if the BOOT command is used
without specifying a device, the system will boot from the first default boot
device that contains bootable software.
NOTE: If included in a string of boot devices, the Ethernet device, EZA0,
should only be placed as the last device of the string. The system will
continuously attempt to boot from EZA0.
Refer to Appendix A for examples.
Supported Boot Devices
Table 3–3 lists the boot devices supported by the CPU. The table correlates
the boot device names expected in a BOOT command with the corresponding
supported devices. The device name used for the bootstrap operation is one
of three:
•
EZA0, if no default boot device has been specified
•
The default boot device specified at initial power-up or through SET
BOOT
•
Name explicitly specified in a BOOT command line
Boot device names consist of a device code of at least two letters (A through
Z) in length, followed by a single-character controller letter (A through Z),
and ending in a device unit number (0 through 16,383).
3–44 KA675/KA680/KA690 CPU System Maintenance
Table 3–3: Boot Devices Supported by the KA675/KA680/KA690
Boot Name
Controller Type
Device Type(s)
[node$]DImu
DUcu
On-board DSSI
KFQSA DSSI
KDA50 MSCP
RDX3 MSCP
RFxx
RFxx
RAxx
RDxx
[node$]DKAu
DUcu
KZQSA SCSI
KRQ50 MSCP
RRD4x
RRD40
[node$]MImu
MUcu
On-board DSSI
TQK50 MSCP
TQK70 MSCP
KLESI
KZQSA SCSI
TF85
TK50
TK70
TU81E
TLZ04
EZA0
XQcu
On-board Ethernet
DESQA
–
–
PRAu
PRB0
MRV11
–
Customer EPROM space –
Disk
Compact Disc
Tape
MKAu
Network
PROM
NOTE: For diskless and tapeless systems that boot software over the
network, select only the Ethernet adapter. All other boot devices are
inappropriate.
3.7.5.2 Setting Boot Flags
The Virtual Memory Boot (VMB) action is qualified by the value passed to
it in R5. R5 contains boot flags that specify conditions of the bootstrap.
The firmware passes to VMB either the R5 value specified in the BOOT
command or the default boot flag value specified with a SET BFLG
command. The VMB boot flags are listed in Table 3–4.
System Setup and Configuration
3–45
Refer to Appendix A for examples.
Table 3–4: Virtual Memory Bootstrap (VMB) Boot Flags
Bit
Name
Description
0
RPB$V_CONV
1
RPB$V_DEBUG
2
RPB$V_INIBPT
3
RPB$V_BBLOCK
4
RPB$V_DIAG
5
RPB$V_BOOBPT
6
RPB$V_HEADER
8
RPB$V_SOLICT
9
RPB$V_HALT
31:28
RPB$V_TOPSYS
Conversational boot. At various points in the system boot
procedure, the bootstrap code solicits parameters and other
input from the console terminal.
Debug. If this flag is set, VMS maps the code for the XDELTA
debugger into the system page tables of the running system.
Initial breakpoint.
If RPB$V_DEBUG is set, the VMS
operating system executes a BPT instruction in module INIT
immediately after enabling mapping.
Secondary bootstrap from bootblock. When set, VMB reads
logical block number 0 of the boot device and tests it for
conformance with the bootblock format. If in conformance, the
block is executed to continue the bootstrap. No attempt is made
to perform a Files–11 bootstrap.
Diagnostic bootstrap. When set, the load image requested is
[SYS0.SYSMAINT]DIAGBOOT.EXE.
Bootstrap breakpoint. When set, a breakpoint instruction is
executed in VMB and control is transferred to XDELTA before
booting.
Image header. When set, VMB transfers control to the address
specified by the file’s image header. When not set, VMB
transfers control to the first location of the load image.
File name solicit. When set, VMB prompts the operator
for the name of the application image file. A maximum 39
character file specification is allocated at RPB$T_FILE. Only
16 characters are utilized in both tape boot and network MOP
V3 booting.
Halt before transfer. When set, VMB halts before transferring
control to the application image.
This field can be any value from 0 through F. This flag changes
the top-level directory name for system disks with multiple
operating systems. For example, if TOPSYS is 1, the top-level
directory name is [SYS1...]. This does not apply to network
bootstraps.
3.7.5.3 Setting the Halt Action
The user-defined halt action feature allows users to determine what action
should be taken on error halts and at power-up. The halt action is defined
using the SET HALT command and overrides the setting of the Break
Enable/Disable switch.
Table 3–5 summarizes the action taken on all halt conditions (excluding
external halts). The user-defined halt is used when the O/S Mailbox halt
action field is 0 and on power-up if breaks are enabled. Refer to Appendix A
for an example of the SET HALT command.
3–46 KA675/KA680/KA690 CPU System Maintenance
For external halts caused by pressing the Halt button on the SCP or
pressing BREAK /CTRL-P (if breaks are enabled), the firmware enters console
mode.
NOTE: Using the console command SET CONTROLP, you can specify the
control character, Ctrl/P , rather than Break to initiate a break signal.
Table 3–5: Actions Taken on a Halt
Reset/
Power-Up
or Halt
Break
Enable
Switch
UserO/S
Defined
MailboX
Halt Action Halt Action Action(s)
T
T
1
1
0,1,3
2,4
x
x
T
0
x
x
F
F
1
0
0
0
0
0
F
F
F
F
x
x
x
x
1
2
3
4
0
0
0
0
F
F
F
x
x
x
x
x
x
1
2
3
Diagnostics, console
Diagnostics, if success boot, if
either fail console
Diagnostics, if success boot, if
either fail console
Console
Restart, if this fails boot, if
that fails console
Restart, if it fails console
Boot, if it fails console
Console
Restart, if this fails boot, if
that fails console
Restart, if it fails console
Boot, if it fails console
Console
"T" indicates that the condition is true.
"F" indicates that the condition is false.
"X" indicates that the condition is "don’t care".
Halt Action 0 = DEFAULT
Halt Action 1 = RESTART
Halt Action 2 = REBOOT
Halt Action 3 = HALT
Halt Action 4 = RESTART_REBOOT
System Setup and Configuration
3–47
Chapter 4
System Initialization and Acceptance
Testing (Normal Operation)
This chapter describes the system initialization, testing, and bootstrap
processes that occur at power-up. In addition, the acceptance test procedure
to be performed when installing a system or whenever adding or replacing
FRUs is described.
4.1 Basic Initialization Flow
On power-up, the firmware identifies the console device, optionally performs
a language inquiry, and runs the diagnostics.
Power-up actions differ, depending on the state of the Power-Up Mode
switch on the console module. The mode switch has three settings: loopback
test, language inquiry, and run. The differences are described below.
The firmware waits for power to stabilize by monitoring SCR<15>(POK).
Once power is stable, the firmware verifies that the console battery
backup RAM (BBU RAM) is valid (backup battery is charged) by checking
SSCCR<31>(BLO). If it is invalid or zero (battery is discharged), BBU RAM
is initialized.
After the battery check, the firmware tries to determine the type of terminal
attached to the console serial line. It uses this information to determine if
multinational support is appropriate.
Power-Up Mode Switch Set to Test
Use the test position on the H3604 to verify a proper connection between
the CPU and the console terminal. During the test, the firmware toggles
between the active and passive states. Refer to Chapter 5 for instructions
on performing loopback tests.
Power-Up Mode Switch Set to Language Inquiry
If the Power-Up Mode switch is set to language inquiry mode, or the
firmware detects that the contents of BBU RAM are invalid, the firmware
System Initialization and Acceptance Testing (Normal Operation)
4–1
prompts you for the language to be used for displaying the following system
messages (if the console terminal supports the multinational character set).
Loading system software.
Failure.
Restarting system software.
Performing normal system tests.
Tests completed.
Normal operation not possible.
Bootfile.
Memory configuration error.
No default boot device has been specified.
Available devices.
Device?
Retrying network bootstrap.
The language selection menu appears under the conditions listed in
Table 4–1. The position of the Break Enable/Disable switch has no effect
on these conditions. The firmware will not prompt for a language if the
console terminal, such as the VT100, does not support the multinational
character set (MCS).
Table 4–1: Language Inquiry on Power-Up or Reset
Mode
Language Not
Previously Set1
Language
Previously Set
Language Inquiry
Run
Prompt2
Prompt
Prompt
No Prompt
1 Action
if contents of BBU RAM invalid same as Language Not Previously Set.
= Language selection menu displayed.
2 Prompt
The language selection menu is shown in Example 4–1. If no response is
received within 30 seconds, the firmware defaults to English (5).
4–2 KA675/KA680/KA690 CPU System Maintenance
Example 4–1: Language Selection Menu
KA6nn-A Vn.n VMB n.n
1) Dansk
2) Deutsch (Deutschland/Österreich)
3) Deutsch (Schweiz)
4) English (United Kingdom)
5) English (United States/Canada)
6) Español
7) Français (Canada)
8) Français (France/Belgique)
9) Français (Suisse)
10) Italiano
11) Nederlands
12) Norsk
13) Português
14) Suomi
15) Svenska
(1..15):
NOTE: The information contained within the parentheses indicates the
specific keyboard variant.
In addition, the console may prompt you for a default boot device following
a successful diagnostic countdown.
After the language inquiry, the firmware continues as if on a normal powerup.
Power-Up Mode Switch Set to Run
The console displays the language selection menu if the Power-Up Mode
switch is set to run mode and the contents of BBU RAM are invalid or a
language has not yet been selected. The next step in the power-up sequence
is to execute the bulk of ROM-based diagnostics. In addition to message
text, a countdown is displayed in Example 4–2.
System Initialization and Acceptance Testing (Normal Operation)
4–3
Example 4–2: Normal Diagnostic Countdown
KA6nn-A Vn.n VMB n.n
Performing normal system tests.
66..65..64..63..62..61..60..59..58..57..56..55..54..53..52..51..
50..49..48..47..46..45..44..43..42..41..40..39..38..37..36..35..
34..33..32..31..30..29..28..27..26..25..24..23..22..21..20..19..
18..17..16..15..14..13..12..11..10..09..08..07..06..05..04..03..
Tests completed.
The console uses the saved console language if the mode switch is set to
run mode and the contents of BBU RAM are valid.
4.2 Power-On Self-Tests (POST)
Power-on self-tests provide core testing of the system kernel. The CPU,
memory, DSSI bus, and Q–bus are tested, certain registers are flushed,
and data structures are set up to initialize and set the system to a known
state for the operating system.
4.2.1 Power-Up Tests for Kernel
In a nonmanufacturing environment where the intended console device
is the serial line unit (SLU), the console program performs the following
actions at power-up:
1. Checks for POK.
2. Establishes SLU as console device.
3. Prints banner message.
The banner message contains the processor name, the version of the
firmware, and the version of VMB. The letter code in the firmware
version indicates if the firmware is pre-field test, field test, or official
release. The first digit indicates the major release number and the
trailing digit indicates the minor release number (Figure 4–1).
4–4 KA675/KA680/KA690 CPU System Maintenance
Figure 4–1: Console Banner
KA6nn-A V n.n, VMB n.n
minor release of VMB
major release of VMB
minor release of firmware
major release of firmware
type of release: X - engineering release
T - field test release
V - volume resease
processor type
MLO-008459
4. Displays language inquiry menu on console if console supports
multinational character set (MCS) and any of the following are true:
•
Battery is dead.
•
Power-Up Mode switch is set to language inquiry mode.
•
Contents of SSC RAM are invalid.
5. Calls the diagnostic executive (DE) with Test Code = 0.
a. DE determines environment is nonmanufacturing from H3604.
b. DE executes script A1 (Tests CPU, Floating Point Accelerator (FPA),
and memory).
While the diagnostics are running, the LEDs on the H3604 display
a hexadecimal test code ranging from F to 3 before booting the
operating system, and 2 to 0 while booting the operating system.
A different countdown appears on the console terminal. Refer to
Table 5–9 for a complete explanation of the power-up test display.
Table 4–2 lists the LED codes and the associated actions performed
at power-up. Example 4–3 shows a successful power-up to a list of
bootable devices.
c.
DE passes control back to the console program.
6. Issues end message and >>> prompt.
System Initialization and Acceptance Testing (Normal Operation)
4–5
Table 4–2: LED Codes
LED ValueActions
F
Initial state on power-up, no code has executed
E
Entered ROM space, some instructions have executed
D
Waiting for power to stabilize (POK)
C
SSC RAM, SSC registers, and ROM checksum tests
B
O-bit memory, interval timer, and virtual mode tests
A
FPA tests
9
Backup cache, primary cache, and memory tests
8
NMC, NCA, memory, and I/O interaction tests
7
CQBIC (Q22–bus) tests
6
Console loopback tests
5
SHAC DSSI subsystem tests
4
SGEC Ethernet subsystem tests
3
"Console I/O" mode
2
Control passed to VMB
1
Control passed to secondary bootstrap
0
"Program I/O" mode, control passed to operating system
4–6 KA675/KA680/KA690 CPU System Maintenance
Example 4–3: Successful Power-Up to List of Bootable Devices
KA6nn-A Vn.n VMB n.n
Performing normal system tests.
66..65..64..63..62..61..60..59..58..57..56..55..54..53..52..51..
50..49..48..47..46..45..44..43..42..41..40..39..38..37..36..35..
34..33..32..31..30..29..28..27..26..25..24..23..22..21..20..19..
18..17..16..15..14..13..12..11..10..09..08..07..06..05..04..03..
Tests completed.
Loading system software.
No default boot device has been specified.
Available devices.
-DIA0 (RF73)
-DIA1 (RF73)
-MIA5 (TF85)
-EZA0 (08-00-2B-06-10-42)
Device? [EZA0]:
4.2.2 Power-Up Tests for Q-Bus Options
Module self-tests run when you power up the system. A module self-test
can detect hard or repeatable errors, but usually not intermittent errors.
Module LEDs display pass/fail test results:
•
A pass by a module self-test does not guarantee that the module is good,
because the test usually checks only the controller logic.
•
A fail by a module self-test is accurate, because the test does not require
any other part of the system to be working.
The following modules do not have LED self-test indicators:
DFA01
DPV11
DRQ3B
KLESI
LPV11
TSV05
The following modules have one green LED, which indicates that the
module is receiving +5 and +12 Vdc and has passed self-tests:
CXA16
CXB16
CXY08
System Initialization and Acceptance Testing (Normal Operation)
4–7
4.2.3 Power-Up Tests for Mass Storage Devices
An RF-series ISE may fail either during initial power-up or during normal
operation. In both cases, the failure is indicated by the lighting of the red
fault LED on the drive’s front panel. The ISE also has a red fault LED, but
it is not visible from the outside of the system enclosure.
If the drive is unable to execute the Power-On Self-Test (POST) successfully,
the red fault LED remains lit and the ready LED does not come on, or both
LEDs remain on.
POST is also used to handle two types of error conditions in the drive:
•
Controller errors are caused by the hardware associated with the
controller function of the drive module. A controller error is fatal to
the operation of the drive, since the controller cannot establish a logical
connection to the host. The red fault LED lights. If this occurs, replace
the drive module.
•
Drive errors are caused by the hardware associated with the drive
control function of the drive module. These errors are not fatal to the
drive, since the drive can establish a logical connection and report the
error to the host. Both LEDs go out for about 1 second, then the red
fault LED lights.
4.3 CPU ROM-Based Diagnostics
The KA675/KA680/KA690 ROM-based diagnostic facility is the primary
diagnostic tool for troubleshooting and testing of the CPU, memory,
Ethernet, and DSSI subsystems. ROM-based diagnostics have significant
advantages:
•
Load time is virtually nonexistent.
•
The boot path is more reliable.
•
Diagnosis is done in a more primitive state.
The ROM-based diagnostics can detect failures in field-replaceable units
(FRUs) other than the CPU module. For example, they can isolate one of
up to four memory modules as FRUs. (Table 5–9 lists the FRUs indicated
by ROM-based diagnostic error messages.)
The diagnostics run automatically on power-up. While the diagnostics are
running, the LED on the H3604 displays a hexadecimal number; while
booting the operating system, 2 through 0 display.
The ROM-based diagnostics are a collection of individual tests with
parameters that you can specify. A data structure called a script points
4–8 KA675/KA680/KA690 CPU System Maintenance
to the tests (see Section 4.3.2). There are several field and manufacturing
scripts.
A program called the diagnostic executive determines which of the available
scripts to invoke. The script sequence varies if the system is in the
manufacturing environment. The diagnostic executive interprets the script
to determine what tests to run, the correct order to run the tests, and the
correct parameters to use for each test.
The diagnostic executive also controls tests so that errors can be detected
and reported. It ensures that when the tests are run, the machine is left
in a consistent and well-defined state.
4.3.1 Diagnostic Tests
Example 4–4 shows a list of the ROM-based tests and utilities. To get this
listing, enter T 9E at the console prompt (T is the abbreviation of TEST).
The column headings have the following meanings:
NOTE: Base addresses shown in this document may not be the same as
the addresses you see when you run T 9E. Run T 9E to get a list of actual
addresses. See Example 4–4.
•
Test is the test number or utility code.
•
Address is the base address of where the test or utility starts in ROM.
If a test fails, entering T FE displays diagnostic state to the console.
You can subtract the base address of the failing test from the last_
exception_pc to find the index into the failing test’s diagnostic listing.
•
Name is a brief description of the test or utility.
•
Parameters shows the parameters for each diagnostic test or utility.
These parameters are encoded in ROM and are provided by the
diagnostic executive. Tests accept up to 10 parameters. The asterisks
(*) represent parameters that are used by the tests but that you cannot
specify individually. These parameters are displayed in error messages,
each one preceded by identifiers P1 through P10.
Parameters that you can specify are written out, as shown in the following
examples:
30
54
2005C33C
20055181
Memory_Init_Bitmap *** mark_Hard_SBEs ******
Virtual_Mode
*********
For example, the virtual mode test contains several parameters, but you
cannot specify any that appear in the table as asterisks. To run this test
individually, enter:
System Initialization and Acceptance Testing (Normal Operation)
4–9
>>>T 54
The MEM_bitmap test, for example, accepts 10 parameters, but you can
only specify mark_hard_SBEs because the rest are asterisks. To map out
solid, single-bit ECC memory errors, type:
>>>T 30 0 0 0 1
Even though you cannot change the first three parameters, you need to
enter either zeros (0) or ones (1) as placeholders. Zeros are more common
and are shown in this example. The zeros are placeholders for parameters
1 through 3, which allows the program to parse the command line correctly.
The diagnostic executive then provides the proper value for the test.
You enter 1 for parameter 4 to indicate that the test should map out solid,
single-bit as well as multi-bit ECC memory errors. You then terminate the
command line by pressing RETURN . You do not need to specify parameters 5
through 10; placeholders are needed only for parameters that precede the
user-definable parameter.
For the most part tests and scripts can be run without any special setup. If
a test or script is run interactively without an intervening power up, such as
after a system crash or shutdown, enter the UNJAM and INIT commands
before running the tests or script. This will ensure that the CPU is in a
well known state. If the commands are not entered, misleading errors may
occur.
Other considerations to be aware of when running individual tests or scripts
interactively:
•
When using the TEST or REPEAT TEST commands, you must specify
a test number, test code or script number following the TEST command
before pressing RETURN .
•
The memory bitmap and Q–bus scatter-gather map are created in main
memory and the memory tests are run with these data structures left
intact. Therefore, the upper portion of memory should not be accessed
to avoid corrupting these data structures. The location of the maps are
displayed using the SHOW MEMORY/FULL command.
4.3.2 Scripts
Most of the tests shown by utility 9E are arranged into scripts. A script
is a data structure that points to various tests and defines the order in
which they are run. Scripts should be thought of as diagnostic tables—
these tables do not contain the actual diagnostic tests themselves, instead
scripts simply define what tests or scripts should be run, the order that the
tests or scripts should be run, and any input parameters to be parsed by
the Diagnostic Executive.
4–10 KA675/KA680/KA690 CPU System Maintenance
Different scripts can run the same set of tests, but in a different order and
/or with different parameters and flags. A script also contains the following
information:
•
The parameters and flags that need to be passed to the test.
•
Where the tests can be run from. For example, certain tests can be run
only from the FEPROM. Other tests are program-independent code,
and can be run from FEPROM or main memory to enhance execution
speed.
•
What is to be shown, if anything, on the console.
•
What is to be shown, if anything, in the LED display.
•
What action to take on errors (halt, repeat, continue).
The power-up script runs every time the system is powered on. You can
also invoke the power-up script at any time by entering T 0.
Additional scripts are included in the ROMs for use in manufacturing and
engineering environments. Customer Services personnel can run these
scripts and tests individually, using the T command. When doing so, note
that certain tests may be dependent upon a state set up from a previous
test. For this reason, use the UNJAM and INITIALIZE commands before
running an individual test. You do not need these commands on system
power-up because the system power-up leaves the machine in a defined
state.
Customer Services Engineers (CSE) with a detailed knowledge of the
system hardware and firmware can also create their own scripts by using
the 9F User Script Utility. Table 4–3 lists the scripts available to Customer
Services.
System Initialization and Acceptance Testing (Normal Operation)
4–11
Example 4–4: Test 9E
>>>T 9E
Test
#
Address
Name
Parameters
___________________________________________________________________________
20053E00 SCB
20054E14 De_executive
30 20063A20 Memory_Init_Bitmap *** mark_Hard_SBEs ******
31 200641BC Memory_Setup_CSRs **********
32 20064CB0 NMC_registers
**********
33 20064E4C NMC_powerup
**
34 2005B730 SSC_ROM
*
35 20067AEC B_Cache_diag_mode bypass_test_mask *********
37 2006868C Cache_w_Memory
bypass_test_mask *********
3F 2006443C Mem_FDM_Addr_shorts *** cont_on_err ******
40 20062608 Memory_count_pages First_board Last_bd Soft_errs_allowed *******
41 2005650C Board_Reset
*
42 2005A3CC Chk_for_Interrupts *****
46 2006782C P_Cache_diag_mode bypass_test_mask *********
47 20063F48 Memory_Refresh
start_a end incr cont_on_err time_seconds *****
48 20061878 Memory_Addr_shorts start_add end_add * cont_on_err pat2 pat3 ****
49 2006342C Memory_FDM
*** cont_on_err ******
4A 20063138 Memory_ECC_SBEs
start_add end_add add_incr cont_on_err ******
4B 20061EDC Memory_Byte_Errors start_add end_add add_incr cont_on_err ******
4C 20062AC8 Memory_ECC_Logic
start_add end_add add_incr cont_on_err ******
4D 200616F8 Memory_Address
start_add end_add add_incr cont_on_err ******
4E 20061CE0 Memory_Byte
start_add end_add add_incr cont_on_err ******
4F 20062814 Memory_Data
start_add end_add add_incr cont_on_err ******
51 2005A88C FPA
*******
52 2005ABCC SSC_Prog_timers
which_timer wait_time_us ***
53 2005AE9C SSC_TOY_Clock
repeat_test_250ms_ea Tolerance ***
54 2005A4A2 Virtual_Mode
*********
55 2005B052 Interval_Timer
*****
56 2005FF38 SHAC_LPBCK
********
58 200607B4 SHAC_RESET
dssi_bus port_number time_secs
59 2005F080 SGEC_LPBCK_ASSIST time_secs **
5C 2005F5E8 SHAC
shac_number *******
5F 2005E36C SGEC
loopback_type no_ram_tests ******
60 2005DD67 SSC_Console_SLU
start_BAUD end_BAUD ******
63 2005B5D4 QDSS_any
input_csr selftest_r0 selftest_r1 ******
80 20065280 CQBIC_memory
bypass_test_mask *********
81 2005B236 Qbus_MSCP
IP_csr ******
82 2005B3FB Qbus_DELQA
device_num_addr ****
83 200577FA QZA_Intlpbck1
controller_number ********
84 20058EB4 QZA_Intlpbck2
controller_number *********
Example 4–4 (continued on next page)
4–12 KA675/KA680/KA690 CPU System Maintenance
Example 4–4 (Cont.): Test 9E
85
86
87
90
91
99
9A
9B
9C
9D
9E
9F
C1
C2
C5
C6
D0
D2
DA
DB
DC
DD
DE
DF
20056A34
20056EF0
2005A0F8
2005AB4A
2005AAE0
20065048
2005D080
20064ECC
2005B7FA
2005E138
2005B208
20060D4C
200566E0
200568B6
2005E25A
20056624
20067400
20065A1C
200684B4
200661B0
200643E0
2006691C
200664D4
20065DF0
QZA_memory
QZA_DMA
QZA_EXTLPBCK
CQBIC_registers
CQBIC_powerup
Flush_Ena_Caches
INTERACTION
Init_memory_16MB
List_CPU_registers
Utility
List_diagnostics
Create_A0_Script
SSC_RAM_Data
SSC_RAM_Data_Addr
SSC_registers
SSC_powerup
V_Cache_diag_mode
O_Bit_diag_mode
PB_Flush_Cache
Speed
NO_Memory_present
B_Cache_Data_debug
B_Cache_Tag_Debug
O_BIT_DEBUG
incr test_pattern controller_number *******
Controller_number main_mem_buf ********
controller_number ****
*
**
dis_flush_virtual dis_flush_backup dis_flush_primary
pass_count disable_device ****
*
*
Expnd_err_msg get_mode init_LEDs clr_ps_cnt
*
**********
*
*
*
*********
bypass_test_mask *********
bypass_test_mask *********
**********
print_speed *********
********
start_add end_add add_incr *******
start_add end_add add_incr *******
start_add end_add add_incr seg_incr ******
Scripts
#
Description
A0
A1
A3
A4
A5
A6
A7
A8
A9
>>>
User defined scripts
Powerup tests, Functional Verify, continue on error, numeric countdown
Functional Verify, stop on error, test # announcements
Loop on A3 Functional Verify
Address shorts test, run fastest way possible
Memory tests, mark only multiple bit errors
Memory tests
Memory acceptance tests, mark single and multi-bit errors, call A7
Memory tests, stop on error
System Initialization and Acceptance Testing (Normal Operation)
4–13
Table 4–3: Scripts Available to Customer Services
Script1
Enter with
TEST
Command
A0
A1
A0
A1, 0
A5
A5
A6
A6
A7
A7, A8
A8
A8
A9
A9
AD
AD
AE
AE, AD
AF
AF
Description
Runs user-defined script. Enter T 9F to create.
Primary power-up script; builds memory bitmap; marks hard
single-bit errors and multi-bit errors. Continues on error.
Runs address shorts test from RAM; invokes tests 3F and 48;
runs test 48 the fastest way possible using fast mode and
running cached from RAM.
Memory test script; initializes memory bitmap and marks only
multiple bit errors.
Memory test portion invoked by script A8. Reruns the memory
tests without rebuilding and reinitializing the bitmap. Run
script A8 once before running script A7 separately to allow
mapping out of both single-bit and double-bit main memory
ECC errors.
Memory acceptance. Running script A8 with script A7 tests
main memory more extensively. It enables hard single-bit and
multibit main memory ECC errors to be marked bad in the
bitmap. Invokes script A7 when it has completed its tests.
Memory tests. Halts and reports the first error. Does not reset
the bitmap or busmap. It is a quick way to specify which test
caused a failure when a hard error is present.
Console program. Runs memory tests, marks bitmap, resets
busmap, and resets caches. Calls script AE.
Console program. Resets memory CSRs and resets caches. Also
called by the INIT command.
Console program. Resets busmap and resets caches.
1 Scripts AD, AE, and AF exist primarily for console program; error displays and progress
messages are suppressed (not recommended for CSE use).
In most cases, the service engineer needs only the scripts shown below for
effective troubleshooting and acceptance testing.
4–14 KA675/KA680/KA690 CPU System Maintenance
Scripts
#
Description
A0
A1
A3
A4
A5
A6
A7
A8
A9
>>>
User defined scripts
Powerup tests, Functional Verify, continue on error, numeric
countdown
Functional Verify, stop on error, test # announcements
Loop on A3 Functional Verify
Address shorts test, run fastest way possible
Memory tests, mark only multiple bit errors
Memory tests
Memory acceptance tests, mark single and multi-bit errors,
call A7
Memory tests, stop on error
4.4 Basic Acceptance Test Procedure
Perform the acceptance testing procedure listed below, after installing a
system, or whenever adding or replacing the following:
CPU module
MS690 memory module
Backplane
DSSI device
H3604 console module
1. While monitoring the test display on the console terminal, run five
error-free passes of the power-up scripts by entering the following
command:
>>>R T 0
If you can not monitor the console terminal during this step, use the
following command.
>>>T A4
Script A4 will halt on an error so that the error message will not scroll
off the screen.
Press
occur.
CTRL/C
to terminate the scripts. Refer to Chapter 5 if failures
2. Double-check the memory configuration, since test 31 can check for only
a few invalid configurations. For example, test 31 cannot report that a
memory board is missing from the configuration, since it has no way of
knowing if the board should be there or not.
System Initialization and Acceptance Testing (Normal Operation)
4–15
To check the memory configuration and to ensure there are no bad
pages, enter the following command line:
>>>SHOW MEMORY/FULL
Memory 0: 00000000 to 01FFFFFF, 32 Mbytes, 0 bad pages
Total of 32 Mbytes, 0 bad pages, 112 reserved pages
Memory Bitmap
-01FF2000 to 01FF3FFF, 16 pages
Console Scratch Area
-01FF4000 to 01FF7FFF, 32 pages
Q-bus Map
-01FF8000 to 01FFFFFF, 64 pages
Scan of Bad Pages
>>>
Memories 0 through 3 are the MS690 memory modules. The Q22–bus
map always spans the top 32 Kbytes of good memory. The memory
bitmap always spans two pages (1 Kbyte) for each 4 Mbytes of memory
configured. Each bit within the memory bit map represents a page of
memory.
Use utility 9C to examine the contents of configuration registers
MEMCON 0–7 to verify the memory configuration:
>>>T 9C
SBR=07FB8000
SLR=00002021 SAVPC=20047F58 SAVPSL=20047F58 BCETSTS=00000000
SCBB=20053E00
P0BR=80000000
P0LR=00100A80
P1BR=00800000 BCETIDX=00000000
P1LR=00600000
SID=13000202
TODR=00000000
ICCS=00000000 BCEDSTS=00000700
ECR=000000CA MAPEN=00000000 BDMTR=20084000 BDMKR=0000007C BCEDIDX=00000010
TCR0=00000005
TIR0=0112BD68 TNIR0=00000000 TIVR0=00000078 BCEDECC=00000000
TCR1=00000001
TIR1=0117BFA9 TNIR1=0000000F TIVR1=0000007C NEDATHI=00000000
RXCS=00000000
RXDB=0000000D
TXCS=00000000
TXDB=00000030 NEDATLO=00000000
SCR=0000D000
DSER=00000000 QBEAR=0000000F
DEAR=00000000
CESR=00000000
QBMBR=07FF8000
BDR=3CFD08AB DLEDR=0000000C SSCCR=00D55570 CMCDSR=0000C108
CBTCR=00004000 IPCR0=0000
CSEAR1=00000000 CSEAR2=00000000 CIOEAR1=00000000
PCSTS=FFFFF800 PCADR=FFFFFFF8 PCCTL=FFFFFE13
ICSR=00000001 CIOEAR2=00000300
CCTL=00000007 BCETAG=00000000
VMAR=000007E0
CNEAR=00000000
NESTS=00000000 CEFSTS=00019200 NEOADR=E005BFD8 NEOCMD=8000FF04 NEICMD=00000000
DSSI_1=03 (BUS_1)
PQBBR_1=03060022
PMCSR_1=00000000
SSHMA_1=00008A20
PSR_1=00000000
PESR_1=00000000
PFAR_1=00000000
PPR_1=00000000
DSSI_2=02 (BUS_0)
PQBBR_2=03060022
PMCSR_2=00000000
SSHMA_2=0000CA20
PSR_2=00000000
PESR_2=00000000
PFAR_2=00000000
PPR_2=00000000
NICSR0=1FFF0003
3=00004030
4=00004050
5=8039FF00
6=83E0F000 7=00000000
NICSR9=04E204E2 10=00040000 11=00000000 12=00000000 13=00000000 15=0000FFFF
NISA=08-00-2B-26-A5-53
MEAR=18406010_ADD=21018040
MESR=00006000
MEMCON_0:3; 0=80000005, 1=84000005, 2=00000007, 3=00000007
MMCDSR=01111000
MEMCON_4:7; 4=00000007, 5=00000007, 6=00000007, 7=00000007
MOAMR=00000000
>>>
To identify registers and register bit fields, see the KA675/KA680
/KA690 CPU Technical Manual.
4–16 KA675/KA680/KA690 CPU System Maintenance
Examine MEMCON 0–7 to verify the memory configuration. Each pair
of MEMCONs maps one MS690 memory module as follows:
MEMCON0–1
MEMCON2–3
MEMCON4–5
MEMCON6–7
First MS690; slot 4, closest to CPU
Second MS690; slot 3
Third MS690; slot 2
Fourth MS690; slot 1, farthest from CPU
Verify the following:
•
The bank enable bit (<31>) in both MEMCONs for each memory
module is set to (8xxx xxxh), which indicates that the base address
for the banks contained on the module is valid.
•
MEMCON bits <2:1> are the signature field and contain the
following value, in relation to the size of the array.
Table 4–4: Signature Field Values
MCSR 0–15
<2:1>
Hex
Equiv
Configuration
00
0
Unassigned
01
2
RAM size 1 Mbit
10
4
RAM size 4 Mbits
11
6
Bank no response
•
MEMCON bits <28:24> indicate the base address for each memory
bank. The first valid bank starts at 0. The memory subsystem can
mix the different sized memory modules (32 MB, 64 MB, and 128
MB). The largest sized memory module will be configured first, no
matter where it is in the system. After all modules of the largest
size are configured, the next largest size will be configured.
•
MEMCONs display 0000 0007 if no memory module is present;
there should be no gaps in the memory configuration.
3. Check the Q22–bus and the Q22–bus logic in the KA675/KA680/KA690
CQBIC chip and the configuration of the Q22–bus, as follows:
System Initialization and Acceptance Testing (Normal Operation)
4–17
>>>SHOW QBUS
Scan of Q-bus I/O Space
-200000DC (760334)=0000
-200000DE (760336)=0AA0
-20001468 (772150)=0000
-2000146A (772152)=0AA0
-20001920 (774440)=FF08
-20001922 (774442)=FF00
-20001924 (774444)=FF2B
-20001926 (774446)=FF09
-20001928 (774450)=FFA3
-2000192A (774452)=FF96
-2000192C (774454)=0050
-2000192E (774456)=1030
-20001940 (774500)=0000
-20001942 (774502)=0BC0
-20001F40 (777500)=0020
RQDX3/KDA50/RRD50/RQC25/KFQSA-DISK
RQDX3/KDA50/RRD50/RQC25/KFQSA-DISK
DESQA
TQK50/TQK70/TU81E/RV20/KFQSA-TAPE
IPCR
Scan of Q-bus Memory Space
>>>
The columns are described below. The examples listed are from the last
line of the example above.
First column = the VAX I/O address of the CSR, in hex (20001F40).
Second column = the Q22–bus address of the CSR, in octal (777500).
Third column = the data, contained at the CSR address, in hex
(0020).
Fourth column = the speculated device name (IPCR, the CPU
interprocessor communications register).
Additional lines for the device are displayed if more than one CSR
exists.
The last line, Scan of Q–bus Memory Space, displays memory residing
on the Q22–bus, if present. VAX memory mapped by the Q22–bus map
is not displayed under SHOW QBUS, but is displayed using SHOW
MEMORY/FULL.
If the system contains an MSCP or TMSCP controller, run test 81. This
test performs the following functions:
Performs step one of the UQ port initialization sequence
Performs the SA wraparound test
Checks the Q22–bus interrupt logic
If you do not specify the CSR address, the test searches for and runs
on the first MSCP device by default. To test the first TMSCP device,
you must specify the first parameter:
>>>T 81 20001940
4–18 KA675/KA680/KA690 CPU System Maintenance
You can specify other addresses if you have multiple MSCP or TMSCP
devices. This action may be useful to isolate a problem with a controller,
the CPU module, or the backplane. Use the VAX I/O address provided
by the SHOW QBUS command to determine the CSR value. If you do
not specify a value, the MSCP device at address 20001468 is tested by
default.
4. Check that all UQSSP, MSCP, TMSCP, and Ethernet controllers and
devices are visible by typing the following command line:
>>>SHOW DEVICE
DSSI Bus 0 Node 0 (ALPHA)
-DIA0 (RF72)
DSSI Bus 0 Node 1 (BETA)
-DIA1 (RF72)
DSSI Bus 0 Node 2 (GAMMA)
-DIA2 (RF72)
DSSI Bus 0 Node 5 (ZETA)
-MIA5 (TF85)
DSSI Bus 0 Node 6 (*)
DSSI Bus 1 Node 7 (*)
Ethernet Adapter
-EZA0 (08-00-2B-08-E8-6E)
Ethernet Adapter 0 (774440)
-XQA0 (08-00-2B-06-16-F2)
In the example, the console displays the node numbers of disk and tape
ISEs it recognizes. The line below each node name and number is the
logical device name DIA0, DIA1, DIA2, and MIA5 in this case.
The two lines marked by an asterisk (*) are for the embedded DSSI
adapters. DSSI node names and node numbers must be unique.
The next two lines show the logical name and station address for the
embedded Ethernet adapter. The last two lines refer to a DESQA
Ethernet controller, its Q22–bus CSR address, its logical name (XQA0),
and its station address.
5. Run one pass of the DSSI internal drive tests (DRVTST and DRVEXR)
using the Diagnostic Utility Protocol (DUP) driver as described in
Section 5.4.
6. If the above steps have completed successfully and you have time to
test the Q–bus options, load MDM (minimum release of MDM 136 is
required for VAX 4000 Model 500 systems). Run the system tests from
System Initialization and Acceptance Testing (Normal Operation)
4–19
the Main Menu. If they run successfully, the system has gone through
its basic checkout and the operating system software can be loaded.
7. Bring up the operating system.
8. Bringing up VMS completes the installation procedures. Run the VMS
User Environment Test Package (UETP) to test that VMS is correctly
installed. Refer to the VAX 3520, 3540 VMS Installation and Operations
(ZKS166) manual for instructions on running UETP.
4.5 Machine State on Power-up
This section describes the state of the kernel after a power-up halt.
The descriptions in this section assume the system has just powered-up
and the power-up diagnostics have successfully completed. The state of
the machine is not defined if individual diagnostics are run or for any
other halts other than a power-up halt (SAVPSL<13:8>(RESTART_CODE)
= 3). Refer to Appendix E for a description of the normal state of CPU
configurable bits following completion of power-up tests.
4.6 Main memory layout and state
Main memory is tested and initialized by the firmware on power-up.
Figure 4–2 is a diagram of how main memory is partitioned after
diagnostics.
4–20 KA675/KA680/KA690 CPU System Maintenance
Figure 4–2: Memory Layout after Power-up Diagnostics
0
.
.
.
.
Available system memory
(pages potentially good or bad)
.
.
.
.
PFN bitmap
PFN bitmap
(always on page boundary and
size in pages n = (# of MB )/2)
n pages
Firmware "scratch memory"
(always 16KB)
32 pages
Q22-Bus Scatter/Gather Map
(always on 32KB boundry)
64 pages
QMR base
.
Potential "bad" memory
.
Top of Memory
MLO-008454
4.6.1 Reserved Main Memory
In order to build the scatter/gather map and the bitmap, the firmware
attempts to find a physically contiguous page aligned 176 Kb block of
memory at the highest possible address that has no multiple bit errors.
Single bit errors are tolerated in this section.
Of the 176 KB, the upper 32 KB is dedicated to the Q22–bus scatter/gather
map, as shown in Figure 4–2. Of the lower portion, up to 128 Kb at the
bottom of the block is allocated to the Page Frame Number (PFN) bitmap.
The size of the PFN bitmap is dependent on the extent of physical memory,
each bit in the bitmap maps one page (512 bytes) of memory. The remainder
of the block between the bitmap and scatter/gather map (minimally 16Kb)
is allocated for the firmware.
4.6.1.1 PFN Bitmap
The PFN bitmap is a data structure that indicates which pages in memory
are deemed usable by operating systems. The bitmap is built by the
diagnostics as a side effect of the memory tests on power-up. The bitmap
always starts on a page boundary. The bitmap requires 1Kb for every 4Mb
of main memory, hence, a 8Mb system requires 2Kb, 16Mb requires 4Kb,
32Mb requires 8Kb, and a 64Mb requires 16Kb. The bitmap does not map
System Initialization and Acceptance Testing (Normal Operation)
4–21
itself or anything above it. There may be memory above the bitmap which
has both good and bad pages.
Each bit in the PFN bitmap corresponds to a page in main memory. There
is a one to one correspondence between a page frame number (origin 0) and
a bit index in the bitmap. A one in the bitmap indicates that the page is
"good" and can be used. A zero indicates that the page is "bad" and should
not be used. By default, a page is flagged "bad", if a multiple bit error occurs
when referencing the page. Single bit errors, regardless of frequency, will
not cause a page to be flagged "bad".
The PFN bitmap is protected by a checksum stored in the NVRAM. The
checksum is a simple byte wide, two’s complement checksum. The sum of
all bytes in the bitmap and the bitmap checksum should result in zero.
4.6.1.2 Scatter/Gather map
On power-up, the scatter/gather map is initialized by the firmware to map to
the first 4Mb of of main memory. Main memory pages will not be mapped, if
there is a corresponding page in Q22–bus memory, or if the page is marked
bad by the PFN bitmap.
On a processor halt other than power-up, the contents of the scatter/gather
map is undefined, and is dependent on operating system usage.
Operating systems should not move the location of the scatter/gather map,
and should access the map only on aligned longwords through the local I/O
space of 20088000 to 2008FFFC, inclusive. The Q22–bus map base register,
(QMBR) is set up by the firmware to point to this area, and should not be
changed by software.
4.6.1.3 Firmware "Scratch Memory"
This section of memory is reserved for the firmware. However, it is only
used after successful execution of the memory diagnostics and initialization
of the PFN bitmap and scatter/gather map. This memory is primarily used
for diagnostic purposes.
4.6.2 Contents of main memory
The contents of main memory are undefined after the diagnostics have run.
Typically, non zero test patterns will be left in memory.
The diagnostics will "scrub" all of main memory, so that no power-up
induced errors remain in the memory system. On the KA675/KA680
/KA690 memory subsystem, the state of the ECC bits and the data bits
are undefined on initial power-up. This can result in single and multiple
bit errors if the locations are read before written, because the ECC bits are
not in agreement with their corresponding data bits. An aligned longword
4–22 KA675/KA680/KA690 CPU System Maintenance
write to every location (done by diagnostics) eliminates all power-up induced
errors.
4.6.3 Memory controller Registers
The CPU firmware assigns bank numbers to the MEMCONn registers in
ascending order, without attempting to disable physical banks that contain
errors. High order unused banks are set to zero. Error loggers should
capture the following bits from each MEMCONn register:
MEMCONn <31> (bank enable bit). As the firmware always assigns
banks in ascending order, knowing which banks are enabled is sufficient
information to derive the bank numbers. MEMCONn <1:0> (bank usage).
This field determines the size of the banks on the particular memory board.
Additional information should be captured from the NMCDSR, MOAMR,
MSER, and MEAR as needed.
4.6.4 On-chip Cache
The CPU on-chip cache is tested during the power-up diagnostics, flushed
and then turned on. The cache is also turned on by the BOOT and the INIT
command.
4.6.5 Translation Buffer
The CPU translation buffer is tested by diagnostics on power-up, but not
used by the firmware because it runs in physical mode. The translation
buffer can be invalidated by using PR$_TBIA, IPR 57.
4.6.6 Halt Protected Space
On the KA675/KA680/KA690 halt protected space spans the 512 KB
FEPROM from 20040000 to 2007FFFF.
The firmware always runs in halt protected space. When passing control
to the bootstrap, the firmware exits the halt protected space, so if halts are
enabled, and the halt line is asserted, the processor will then halt before
booting.
4.7 Operating System Bootstrap
Bootstrapping is the process by which an operating system loads and
assumes control of the system.
The KA675/KA680/KA690 supports
bootstrap of the VAX/VMS and VAXELN operating systems. Additionally,
the KA675/KA680/KA690 will boot MDM diagnostics and any user
application image which conforms to the boot formats described herein.
System Initialization and Acceptance Testing (Normal Operation)
4–23
On the KA675/KA680/KA690 a bootstrap occurs whenever a BOOT
command is issued at the console or whenever the processor halts and the
conditions specified in the Table 3–5 for automatic bootstrap are satisfied.
4.7.1 Preparing for the Bootstrap
Prior to dispatching to the primary bootstrap (VMB), the firmware
initializes the system to a known state. The initialization sequence follows:
1. Check the console program mailbox "bootstrap in progress" bit
(CPMBX<2>(BIP)). If it is set, bootstrap fails.
2. If this is an automatic bootstrap, print the message "Loading system
software." on the console terminal.
3. Set CPMBX<2>(BIP).
4. Validate the Page Frame Number (PFN) bitmap.
checksum is invalid, then:
If PFN bitmap
a. Perform an UNJAM .
b. Perform an INIT .
c.
Retest memory and rebuild PFN bitmap.
5. Validate the boot device name. If none exists, supply a list of available
devices and prompt user for a device. If no device is entered within 30
seconds, use EZA0.
6. Write a form of this BOOT request including the active boot flags and
boot device on the console, for example "(BOOT/R5:0 DUA0)".
7. Initialize the Q22–bus Scatter/Gather map.
a. Set IPCR<8>(AUX_HLT).
b. Clear IPCR<5>(LMEAE).
c.
Perform an UNJAM .
d. Perform an INIT .
e.
If an arbiter, map all vacant Q22–bus pages to the corresponding
page in local memory and validate each entry if that page is "good".
f.
Set IPCR<5>(LMEAE).
8. Search for a 128Kb contiguous block of good memory as defined by the
PFN bitmap. If 128Kb can not be found, the bootstrap fails.
4–24 KA675/KA680/KA690 CPU System Maintenance
9. Initialize the general purpose registers as follows:
R0
R2
R3
R4
R5
R10
R11
AP
SP
PC
R1, R6, R7, R8,
R9, FP
Address of descriptor of boot device name; 0 if none specified
Length of PFN bitmap in bytes
Address of PFN bitmap
Time-of-day of bootstrap from PR$_TODR
Boot flags
Halt PC value
Halt PSL value (without halt code and map enable)
Halt code
Base of 128-Kbyte good memory block + 512
Base of 128-Kbyte good memory block + 512
0
10. Copy the VMB image from FEPROM to local memory beginning at the
base of the 128Kb good memory block + 512.
11. Exit from the firmware to memory resident VMB.
On entry to VMB the processor is running at IPL 31 on the interrupt stack
with memory management disabled. Also, local memory is partitioned as
shown in Figure 4–3.
System Initialization and Acceptance Testing (Normal Operation)
4–25
Figure 4–3: Memory Layout prior to VMB Entry
0
.
Potential "bad" memory
.
Base
Reserved for RPB, initial stack
Base+512(SP,PC)
256 pages for VMB
128KB block of
"good" memory
(page aligned)
VMB image
Balance of 128KB block
to be used for SCB, stack,
and the secondary bootstrap.
.
.
.
Unused memory
.
.
.
PFN bitmap
PFN bitmap
(always on page boundary and
size in pages n = (# of MB )/2)
n pages
Firmware "scratch memory"
(always 16KB)
32 pages
Q22-Bus Scatter/Gather Map
(always on 32KB boundry)
64 pages
QMR base
.
Potential "bad" memory
.
Top of Memory
MLO-008455
4.7.2 Primary Bootstrap Procedures (VMB)
Virtual Memory Boot (VMB) is the primary bootstrap for booting VAX
processors. On the KA675/KA680/KA690 module, VMB is resident in the
firmware and is copied into main memory before control is transferred to
it. VMB then loads the secondary bootstrap image and transfers control to
it.
4–26 KA675/KA680/KA690 CPU System Maintenance
In certain cases, such as VAXELN, VMB actually loads the operating
system directly. However, for the purpose of this discussion "secondary
bootstrap" refers to any VMB loadable image.
VMB inherits a well defined environment and is responsible for further
initialization. The following summarizes the operation of VMB.
1. Initialize a two page SCB on the first page boundary above VMB.
2. Allocate a three page stack above the SCB.
3. Initialize the Restart Parameter Block (RPB).
4. Initialize the secondary bootstrap argument list.
5. If not a PROM boot, locate a minimum of 3 consecutive valid QMRs.
6. Write "2" to the diagnostic LEDs and display "2.." on the console to
indicate that VMB is searching for the device.
7. Optionally, solicit from the console a "Bootfile: " name.
8. Write the name of the boot device from which VMB will attempt to boot
on the console, for example, "-DUA0".
9. Copy the secondary bootstrap from the boot device into local memory
above the stack. If this fails, the bootstrap fails.
10. Write "1" to the diagnostic LEDs and display "1.." on the console to
indicate that VMB has found the secondary bootstrap image on the
boot device and has loaded the image into local memory.
11. Clear CPMBX<2>(BIP) and CPMBX<3>(RIP).
12. Write "0" to the diagnostic LEDs and display "0.." on the console to
indicate that VMB is now transferring control to the loaded image.
13. Transfer control to the loaded image with the following register usage.
R5
R10
R11
AP
SP
Transfer address in secondary bootstrap image
Base address of secondary bootstrap memory
Base address of RPB
Base address of secondary boot parameter block
Base address of secondary boot parameter block
If the bootstrap operation fails, VMB relinquishes control to the console by
halting with a HALT instruction. VMB makes no assumptions about the
location of Q22–bus memory. However, VMB searches through the Q22–bus
Map Registers (QMRs) for the first QMR marked "valid". VMB requires
minimally 3 and maximally 129 contiguous "valid" maps to complete a
bootstrap operation. If the search exhausts all map registers or there are
System Initialization and Acceptance Testing (Normal Operation)
4–27
fewer than the required number of "valid" maps, a bootstrap cannot be
performed. It is recommended that a suitable block of Q22–bus memory
address space be available (unmapped to other devices) for proper operation.
After a successful bootstrap operation, control is passed to the secondary
bootstrap image with the memory layout as shown in Figure 4–4.
4–28 KA675/KA680/KA690 CPU System Maintenance
Figure 4–4: Memory Layout at VMB Exit
0
.
Potential "bad" memory
.
Base
Reserved for RPB, initial stack
Base+512(SP,PC)
VMB image
Next page
SCB (2 pages)
Next page+1024
256 pages for VMB
128KB block of
"good" memory
(page aligned)
Stack (3 pages)
Next page+2560
Secondary bootstrap image
(potemtially exceeds block)
.
.
.
Unused memory
.
.
.
PFN bitmap
PFN bitmap
(always on page boundary and
size in pages n = (# of MB )/2)
n pages
Firmware "scratch memory"
(always 16KB)
32 pages
Q22-Bus Scatter/Gather Map
(always on 32KB boundry)
64 pages
QMR base
.
Potential "bad" memory
.
Top of Memory
MLO-008456
In the event that an operating system has an extraordinarily large
secondary bootstrap which overflows the 128Kb of "good" memory, VMB
loads the remainder of the image in memory above the "good" block.
System Initialization and Acceptance Testing (Normal Operation)
4–29
However, if there are not enough contiguous "good" pages above the block
to load the remainder of the image, the bootstrap fails.
4.7.3 Device Dependent Secondary Bootstrap Procedures
The following sections describe the various device dependent boot
procedures.
4.7.3.1 Disk and Tape Bootstrap Procedure
The disk and tape bootstrap supports Files–11 lookup (supporting only the
ODS level 2 file structure) or the boot block mechanism (used in PROM
boot also). Of the standard DEC operating systems VMS and ELN use the
Files–11 bootstrap procedure and Ultrix-32 uses the boot block mechanism.
VMB first attempts a Files–11 lookup, unless the RPB$V_BBLOCK boot
flag is set. If VMB determines that the designated boot disk is a Files–11
volume, it searches the volume for the designated boot program, usually
[SYS0.SYSEXE]SYSBOOT.EXE. However, VMB can request a diagnostic
image or prompt the user for an alternate file specification. If the boot
image can’t be found, VMB fails.
If the volume is not a Files–11 volume or the RPB$V_BBLOCK boot flag
was set, the boot block mechanism proceeds as follows:
1. Read logical block 0 of the selected boot device (this is the boot block).
2. Validate that the contents of the boot block conform to the boot block
format (see below).
3. Use the boot block to find and read in the secondary bootstrap.
4. Transfer control to the secondary bootstrap image, just as for a Files–11
boot.
The format of the boot block must conform to that shown in Figure 4–5.
4–30 KA675/KA680/KA690 CPU System Maintenance
Figure 4–5: Boot Block Format
31
24 23
BB-0:
1
0
16 15
n
any value
low LBN
high LBN
(The next segment is also used as a PROM "signature block".)
0
BB+(2*n)+0:
CHK
k
18 (Hex)
any value, most likely 0
BB+(2*n)+8:
size in blocks of the image
BB+(2*n)+12:
load offset
BB+(2*n)+16:
offset into image to start
BB+(2*n)+20:
sum of the previous three longwords
Where:
1) the 18 (hex) indicates this is a VAX instruction set
2) 18 (hex) + "k" = the one’s comllement if "CHK"
MLO-008457
4.7.3.2 PROM Bootstrap Procedure
The PROM bootstrap uses a variant of the boot block mechanism. VMB
searches for a valid PROM "signature block" , the second segment of the
boot block defined in Figure 4–5. If PRA0 is the selected "device", then VMB
searches through Q22–bus memory on 16Kb boundaries. If the selected
"device" is PRB0, VMB checks the top 4096 byte block of the FEPROM.
At each boundary, VMB :
1. Validates the readability of that Q22–bus memory page.
2. If readable, check to see if it contains a valid PROM signature block.
If verification passes, the PROM image will be copied into main memory
and VMB will transfer control to that image at the offset specified in the
PROM bootblock. If not, the next page will be tested.
System Initialization and Acceptance Testing (Normal Operation)
4–31
Note that it is not necessary that the boot image actually reside in PROM.
Any boot image in Q22–bus memory space with a valid signature block on
a 16KB boundary is a candidate. Indeed, auxiliary bootstrap assumes that
the image is in shared memory.
The PROM image is copied into main memory in 127 page "chunks" until
the entire PROM is moved. All destination pages beyond the primary 128Kb
block are verified to make sure they are marked good in the PFN bitmap.
The PROM must be copied contiguously and if all required pages cannot fit
into the memory immediately following the VMB image, the boot fails.
4.7.3.3 MOP Ethernet Functions and Network Bootstrap Procedure
Whenever a network bootstrap is selected on a KA675/KA680/KA690, the
VMB code makes continuous attempts to boot from the network. VMB uses
the DNA Maintenance Operations Protocol (MOP) as the transport protocol
for network bootstraps and other network operations. Once a network boot
has been invoked, VMB turns on the designated network link and repeats
load attempt, until either a successful boot occurs, a fatal controller error
occurs, or VMB is halted from the operator console.
The KA675/KA680/KA690 supports the load of a standard operating
system, a diagnostic image, or a user-designated program via network
bootstraps. The default image is the standard operating system, however,
a user may select an alternate image by setting either the RPB$V_DIAG
bit or in the RPB$V_SOLICT bit in the boot flag longword R5. Note that
the RPB$V_SOLICT bit has precedence over the RPB$V_DIAG bit. Hence,
if both bits are set, then the solicited file is requested.
NOTE: VMB accepts a maximum 39-characters for a file specification for
solicited boots. However, MOP V3 only supports a 16 character file name. If
the network server is running VMS, the following defaults apply to the file
specification: the directory MOM$LOAD:, and the extension .SYS. Therefore,
the file specification need only consist of the filename if the default directory
and extension attributes are used.
The KA675/KA680/KA690 VMB uses the MOP program load sequence
for bootstrapping the module and the MOP "dump/load" protocol type for
load related message exchanges. The types of MOP message used in the
exchange are listed in Table 4–5 and Table 4–6.
VMB, the requester, starts by sending a REQ_PROGRAM message to the
MOP ’dump/load’ multicast address. It then waits for a response in the
form of a VOLUNTEER message from another node on the network, the
MOP server. If a response is received, then the destination address is
changed from the multicast address to the node address of the server and
4–32 KA675/KA680/KA690 CPU System Maintenance
the same REQ_PROGRAM message is retransmitted to the server as an
Acknowledge.
Next, VMB begins sending REQ_MEM_LOAD messages to the server. The
server responds with either:
•
MEM_LOAD message, while there is still more to load.
•
MEM_LOAD_w_XFER, if it is the end of the image.
•
PARAM_LOAD_w_XFER, if it is the end of the image and operating
system parameters are required.
The "load number" field in the load messages is used to synchronize the load
sequence. At the beginning of the exchange, both the requester and server
initialize the load number. The requester only increments the load number
if a load packet has been successfully received and loaded. This forms the
Acknowledge to each exchange. The server will resend a packet with a
specific load number, until it sees the load number incremented. The final
Acknowledge is sent by the requester and has a load number equivalent to
the load number of the appropriate LOAD_w_XFER message + 1.
Because the request for load assistance is a MOP "must transact" operation,
the network bootstrap continues indefinitely until a volunteer is found.
The REQ_PROGRAM message is sent out in bursts of eight at four second
intervals, the first four in MOP Version four IEEE 802.3 format and the
last four in MOP Version 3 Ethernet format. The backoff period between
bursts doubles each cycle from an initial value of four seconds, to eight
seconds,... up to a maximum of five minutes. However, to reduce the
likelihood of many nodes posting requests in lock-step, a random "jitter"
is applied to the backoff period. The actual backoff time is computed as
(.75+(.5*RND(x)))*BACKOFF, where 0<=x<1.
4.7.3.4 Network "Listening"
While the CPU module is waiting for a load volunteer during bootstrap,
it "listens" on the network for other maintenance messages directed to the
node and periodically identifies itself at the end of each 8- to 12-minute
interval before a bootstrap retry. In particular, this "listener" supplements
the Maintenance Operation Protocol (MOP) functions of the VMB load
requester typically found in bootstrap firmware and supports.
•
A remote console server that generates COUNTERS messages in
response to REQ_COUNTERS messages, unsolicited SYSTEM_ID
messages every 8 to 12 minutes, and solicited SYSTEM_ID messages
in response to REQUEST_ID messages, as well as recognition of BOOT
messages.
System Initialization and Acceptance Testing (Normal Operation)
4–33
•
A loopback server that responds to Ethernet loopback messages by
echoing the message to the requester.
•
An IEEE 802.2 responder that replies to both XID and TEST messages.
During network bootstrap operation, the KA675/KA680/KA690 complies
with the requirements defined in the "NI Node Architecture Specification"
for a primitive node. The firmware listens only to MOP "Load/Dump",
MOP "Remote Console", Ethernet "Loopback Assistance", and IEEE 802.3
XID/TEST messages (listed in Table 4–7) directed to the Ethernet physical
address of the node. All other Ethernet protocols are filtered by the network
device driver.
The MOP functions and message types, which are supported by the KA675
/KA680/KA690, are summarized in Tables 4–5 and 4–7.
4–34 KA675/KA680/KA690 CPU System Maintenance
Table 4–5: Network Maintenance Operations Summary
Function
Role
Transmit
Receive
MOP Ethernet and IEEE 802.3 Messages1
Dump
Load
Console
Requester
—–
—–
Server
—–
—–
Requester
REQ_PROGRAM2 to solicit
VOLUNTEER
REQ_MEM_LOAD to solicit & ACK
MEM_LOAD
or
MEM_LOAD_w_XFER
or
PARAM_LOAD_w_XFER
Server
—–
—–
Requester
—–
—–
Server
COUNTERS
in response to
REQ_COUNTERS
SYSTEM_ID3
in response to
REQUEST_ID
BOOT
Loopback
Requester
—–
Server
LOOPED_DATA4
—–
in response to
LOOP_DATA
1 All unsolicited messages are sent in Ethernet (MOP V3) and IEEE 802.2 (MOP V4), until
the MOP version of the server is known. All solicited messages are sent in the format used
for the request.
2 The initial REQ_PROGRAM message is sent to the dumpload multicast address. If an
assistance VOLUNTEER message is received, then the responder’s address is used as the
destination to repeat the REQ_PROGRAM message and for all subsequent REQ_MEM_LOAD
messages.
3 SYSTEM_ID messages are sent out every 8 to 12 minutes to the remote console multicast
address and, on receipt of a REQUEST_ID message, they are sent to the initiator.
4 LOOPED_DATA messages are sent out in response to LOOP_DATA messages.
These
messages are actually in Ethernet LOOP TEST format, not in MOP format, and when sent in
Ethernet frames, omit the additional length field (padding is disabled).
System Initialization and Acceptance Testing (Normal Operation)
4–35
Table 4–5 (Cont.): Network Maintenance Operations Summary
Function
Role
Transmit
Receive
IEEE 802.3 Messages5
Exchange ID Requester
Test
5 IEEE
—–
—–
Server
XID_RSP
in response to
Requester
—–
Server
TEST_RSP
XID_CMD
—–
in response to
TEST_CMD
802.2 support of XID and TEST is limited to Class 1 operations.
Table 4–6:
Supported MOP Messages
Message Type
Message Fields
DUMP/LOAD
MEM_LOAD_w_XFER Code
00
Load #
nn
Load addr
aa-aa-aa-aa
Image data
None
MEM_LOAD
Code
02
Load #
nn
Load addr
aa-aa-aa-aa
Image data
dd-...
REQ_PROGRAM
Code
08
Device
25 LQA
49 SGEC
Format
01 V3
04 V4
Program
SW ID 3
02 Sys
C-17 1
C-128 2
If C[1]
>00 Len
00 No ID
Xfer addr
aa-aa-aa-aa
Procesr
00 Sys
Info
(see SYSTEM_ID)
FF OS
FE Maint
REQ_MEM_LOAD
Code
0A
Load #
nn
Error
ee
1 MOP
V3.0 only.
x4.0 only.
3 Software ID field is load from the string stored in the 40 byte field, RPB$T_FILE, of the RPB
on a solicited boot.
2 MOP
4–36 KA675/KA680/KA690 CPU System Maintenance
Table 4–6 (Cont.):
Supported MOP Messages
Message Type
Message Fields
DUMP/LOAD
PARM_LOAD_w_XFERCode
14
VOLUNTEER
Load #
nn
Prm typ
01
02
03
04
05
06
00 End
Prm len
I-16
I-06
I-16
I-06
0A
08
Prm val
Target name 1
Target addr 1
Host name 1
Host addr 1
Host time 1
Host time 2
Xfer addr
aa-aa-aa-aa
Code
03
REMOTE CONSOLE
REQUEST_ID
Code
05
Rsrvd
xx
Recpt #
nn-nn
SYSTEM_ID
Code
07
Rsrvd
xx
Recpt #
nn-nn
or
00-00
REQ_COUNTERS
Code
09
Recpt #
nn-nn
COUNTERS
Code
0B
Recpt #
nn-nn
1 MOP
2 MOP
Info type
01-00 Version
02-00 Functions
07-00 HW addr
64-00 Device
90-01 Datalink
91-01 Bufr size
Info len
03
02
06
01
01
02
Info value
04-00-00
00-59
ee-ee-ee-ee-ee-ee
25 or 49
01
06-04
Counter block
V3.0 only.
x4.0 only.
System Initialization and Acceptance Testing (Normal Operation)
4–37
Table 4–6 (Cont.):
Supported MOP Messages
Message Type
Message Fields
REMOTE CONSOLE
BOOT 4
Code
06
Verification
vv-vv-vv-vv-vv-vv-vvvv
Procesr
00 Sys
Control
xx
Dev ID
C-17
SW ID 3
Script ID 2
C-128
(see
REQ_PROGRAM)
LOOPBACK
LOOP_DATA
Skpcnt
nn-nn
LOOPED_DATA
Skpcnt
nn-nn
Skipped bytes
bb-...
Function
00-02 Forward data
Forward addr
ee-ee-ee-ee-ee-ee
Data
dd-...
Skipped bytes
bb-...
Function
00-01 Reply
Recpt #
nn-nn
Data
dd-...
IEEE 802.2
XID_CMD/RSP
Form
81
Class
01
TEST_CMD/RSP
Optional data.
Rx window size (K)
00
2 MOP
x4.0 only.
ID field is load from the string stored in the 40 byte field, RPB$T_FILE, of the RPB
on a solicited boot.
4 A BOOT message is not verified, because in this context, a boot is already in progress.
However, a received BOOT message will cause the boot backoff timer to be reset to it’s
minimum value.
3 Software
Table 4–7: MOP Multicast Addresses and Protocol Specifiers
Function
Address
IEEE 1
Prefix
Protocol
Owner
Dump/Load
AB-00-00-01-00-00
08-00-2B
60-01
Digital
Remote Console
AB-00-00-02-00-00
08-00-2B
60-02
Digital
Loopback Assistance
CF-00-00-00-00-002
08-00-2B
90-00
Digital
1 MOP
2 Not
V4.0 only.
used.
4–38 KA675/KA680/KA690 CPU System Maintenance
4.8 Operating System Restart
An operating system restart is the process of bringing up the operating
system from a known initialization state following a processor halt. This
procedure is often called restart or warmstart, and should not be confused
with a processor restart which results in firmware entry.
On the KA675/KA680/KA690 a restart occurs, if the conditions specified in
Table 3–5 are satisfied.
To restart a halted operating system, the firmware searches system memory
for the Restart Parameter Block (RPB), a data structure constructed for
this purpose by VMB. (Refer to Table D–2 in Appendix D for a detailed
description of this data structure.) If a valid RPB is found, the firmware
passes control to the operating system at an address specified in the RPB.
The firmware keeps a "restart in progress" (RIP) flag in CPMBX which it
uses to avoid repeated attempts to restart a failing operating system. An
additional "restart in progress" flag is maintained by the operating system
in the RPB .
The firmware uses the following algorithm to restart the operating system:
1. Check CPMBX<3>(RIP). If it is set, restart fails.
2. Print the message "Restarting system software." on the console
terminal.
3. Set CPMBX<3>(RIP).
4. Search for a valid RPB. If none is found, restart fails.
5. Check the operating system RPB$L_RSTRTFLG<0>(RIP) flag. If it is
set, restart fails.
6. Write "0" on the diagnostic LEDs.
7. Dispatch to the restart address, RPB$L_RESTART, with :
SP
AP
PSL
PR$_MAPEN
Physical address of the RPB plus 512
Halt code
041F0000
0
If the restart is successful, the operating system must clear CPMBX<3>(RIP).
If restart fails, the firmware prints "Restart failure." on the system console.
System Initialization and Acceptance Testing (Normal Operation)
4–39
4.8.1 Locating the RPB
The RPB is a page aligned control block which can be identified by the first
three longwords. The format of the RPB "signature" is shown below: (Refer
to Table D–2 in Appendix D for a complete description of the RPB.)
Figure 4–6: Locating the Restart Parameter Block
RPB: +00
Physical address of the RPB
+04
physical address of the restart routine
+08
checksum of first 31 longwords of restart routine
MLO-008458
The firmware uses the following algorithm to find a valid RPB:
1. Search for a page of memory that contains its address in the first
longword. If none is found, the search for a valid RPB has failed.
2. Read the second longword in the page (the physical address of the
restart routine). If it is not a valid physical address, or if it is zero,
return to step 1. The check for zero is necessary to ensure that a page
of zeros does not pass the test for a valid RPB.
3. Calculate the 32 bit twos-complement sum (ignoring overflows) of the
first 31 longwords of the restart routine. If the sum does not match the
third longword of the RPB, return to step 1.
4. A valid RPB has been found.
4–40 KA675/KA680/KA690 CPU System Maintenance
Chapter 5
System Troubleshooting and
Diagnostics
This chapter provides troubleshooting information for the two primary
diagnostic methods: online, interpreting error logs to isolate the FRU; and
offline, interpreting ROM-based diagnostic messages to isolate the FRU.
In addition, information on testing DSSI storage devices, using MOP
Ethernet functions to isolate errors, and interpreting UETP failures, is
provided.
The chapter concludes with a section on running loopback tests to test the
console port, embedded Ethernet ports, Embedded DSSI busses, and Q–bus
modules.
5.1 Basic Troubleshooting Flow
Before troubleshooting any system problem, check the site maintenance
log for the system’s service history. Be sure to ask the system manager the
following two questions:
•
Has the system been used before and did it work correctly?
•
Have changes (changes to hardware, updates to firmware or software)
been made to the system recently?
Four common problems occur when you make a change to the system:
1. Incorrect cabling
2. Module configuration errors (incorrect CSR addresses and interrupt
vectors)
3. Incorrect grant continuity
4. Incorrect bus node ID plugs
In addition, consider the following:
•
If you have received error notification using VAXsimPLUS, check the
mail messages and error logs as described in Section 5.2.
System Troubleshooting and Diagnostics
5–1
•
If the operating system fails to boot (or appears to fail), check the
console terminal screen for an error message. If the terminal displays
an error message, see Section 5.3.
•
Check the LEDs on the device you suspect is bad. If no errors are
indicated by the device LEDs, run the ROM-based diagnostics described
in this chapter.
•
If the system boots successfully, but a device seems to fail or
an intermittent failure occurs, check the error log as described in
Section 5.2.
When troubleshooting, note the status of cables and connectors before you
perform each step. Label cables before you disconnect them. This step
saves you time and prevents you from introducing new problems.
Most communications modules use floating CSR addresses and interrupt
vectors. If you remove a module from the system, you may have to change
the addresses and vectors of other modules.
If you change the system configuration, run the CONFIGURE utility at the
console I/O prompt (>>>) to determine the CSR addresses and interrupt
vectors recommended by Digital. These recommended values simplify
the use of the MDM diagnostic package and are compatible with VMS
device drivers. You can select nonstandard addresses, but they require
a special setup for use with VMS drivers and MDM. See the MicroVAX
Diagnostic Monitor User’s Guide for information about the CONNECT and
IGNORE commands, which are used to set up MDM for testing nonstandard
configurations.
In addition, see Table 5–1 and Table 5–2 for possible problems and power
supply status indicators.
5–2 KA675/KA680/KA690 CPU System Maintenance
Table 5–1: Console Terminal/Console Module Problems
Problem
First Steps
No Console Message
Check the Power switch on both the console terminal and the
system. If the terminal has a DC OK LED, be sure it is lit.
Check the cabling to the console terminal.
Check the terminal setup.
Check the power supply status indicators. See Table 5–2.
Check fuse F2 on the console model. See Section 5.7.
H3604 Display Off
Check the CPU module LEDs and the H3604 cabling.
H3604 Displays Error
See Table 5–9 to determine error status.
Table 5–2: Power Supply Status Indicators
AC
Present
DC OK
Over
Temp
Fan
Failure
Off
Off
Off
Off
System not plugged in, AC source not
present, or system circuit breaker tripped.
On
Off
Off
Off
Overcurrent or overvoltage protection
circuits activated.
On
Off
On
Off
Excessive ambient temp; air vents blocked
On
Off
Off
On
Failure of one or both system fans
On
On
Off
Off
Normal operation
Probable Cause
5.2 Product Fault Management and Symptom
Directed Diagnosis
This section describes how errors are handled by the microcode and
software, how the errors are logged, and how, through the Symptom
Directed Diagnosis (SDD) tool, VAXsimPLUS, errors are brought to the
attention of the user. This section also provides the service theory used to
interpret error logs to isolate the FRU. Interpreting error logs to isolate the
FRU is the primary method of diagnosis.
System Troubleshooting and Diagnostics
5–3
5.2.1 General Exception and Interrupt Handling
This section describes the first step of error notification: the errors are
first handled by the microcode and then are dispatched to the VMS error
handler.
The kernel uses the NVAX core chipset: NVAX CPU, NVAX Memory
Controller (NMC), and NDAL to CDAL adapter (NCA).
Internal errors within the NVAX CPU result in machine check exceptions,
through System Control Block (SCB) vector 004, or soft error interrupts at
Interrupt Priority Level (IPL) 1A, SCB vector 054 hex.
External errors to the NVAX CPU, which are detected by the NMC or NDAL
to CDAL adapter (NCA), usually result in these chips posting an error
condition to the NVAX CPU. The NVAX CPU will then generate a machine
check exception through SCB vector 004, hard error interrupt, IPL 1D,
through SCB vector 060 (hex), or a soft error interrupt through SCB vector
054.
External errors to the NMC and NCA, which are detected by chips on the
CDAL busses for transactions which originated by the NVAX CPU, are
typically signaled back to the NCA adapter. The NCA adapter will post
an error signal back to the NVAX CPU which generates a machine check
or high level interrupt.
In the case of Direct Memory Access (DMA) transactions where the NCA
or NMC detects the error, the errors are typically signaled back to the
CDAL-Bus device, but not posted to the NVAX CPU. In these cases the
CDAL-Bus device typically posts a device level interrupt to the NVAX CPU
via the NCA. In almost all cases, error state is latched by the NMC and
NCA. Although these errors won’t result in a machine check exception or
high level interrupt (IPL 14-17 versus device level IPL 1A, 1D), the VMS
machine check handler has a polling routine which will search for this state
at one second intervals. This will result in the host logging a polled error
entry.
These conditions cover all of the cases which will eventually be handled
by the VMS error handler. The VMS error handler will generate entries
that correspond to the machine check exception, hard or soft error interrupt
type, or polled error.
5.2.2 VMS Error Handling
Upon detection of a machine check exception, hard error interrupt, soft
error interrupt or polled error, VMS will perform the following actions:
•
Snapshot the state of the kernel.
5–4 KA675/KA680/KA690 CPU System Maintenance
•
In most entry points, disable the caches.
•
If it is a machine check and if the machine check is recoverable,
determine if instruction retry is possible.
Instruction retry is possible if one of the following conditions is true:
1. If PCSTS <10>PTE_ER = 0:
Check that (ISTATE2 <07>VR = 1) or (PSL <27> FPD = 1)
Otherwise crash the system or process depending on PSL <25:24>
Current Mode.
2. If PCSTS <10>PTE_ER = 1:
Check that (ISTATE2 <07>VR = 1) and (PSL <27>FPD = 0) and
(PCSTS <09>PTE_ER_WR = 0)
Otherwise crash the system.
ISTATE2 is a longword in the machine check stack frame at offset
(SP)+24; PSL is a longword in the machine check stack frame at offset
(SP)+32; VR is the VAX Restart flag; and FPD is the First Part Done
flag.
•
Check to see if the threshold has been exceeded for various errors
(typically the threshold is exceeded if 3 errors occur within a 10 minute
interval).
•
If the threshold has been exceeded for a particular type of cache error,
mark a flag that will signify that this resource is to be disabled (the
cache will be disabled in most, but not all, cases).
•
Update the SYSTAT software register with results of error/fault
handling.
•
For memory uncorrectable Error Correction Code (ECC) errors:
— Mark page bad and attempt to replace page.
— Fill in MEMCON software register with memory configuration and
error status for use in FRU isolation.
•
For memory single-bit correctable ECC errors:
— Fill in Corrected Read Data (CRD) entry FOOTPRINT with set,
bank, and syndrome information for use in FRU isolation.
— Update the CRD entry for time, address range, and count;
fill the MEMCON software register with memory configuration
information.
System Troubleshooting and Diagnostics
5–5
— Scrub memory location for first occurrence of error within a
particular footprint. If second or more occurrence within a footprint,
mark page bad in hopes that page will be replaced later. Disable
soft error logging for 10 minutes if threshold is exceeded.
— Signify that CRD buffer be logged for the following events: system
shutdown (operator shutdown or crash), hard single-cell address
within footprint, multiple addresses within footprint, memory
uncorrectable ECC error, or CRD buffer full.
•
For ownership memory correctable ECC error, scrub location.
•
Log error.
•
Crash process or system, dependent upon PSL (Current Mode) with a
fatal bugcheck for the following situations:
— Retry is not possible.
— Memory page could not be replaced for uncorrectable ECC memory
error.
— Uncorrectable tag store ECC errors present in writeback cache.
— Uncorrectable data store ECC errors present in writeback cache for
locations marked as OWNED.
— Most INT60 errors.
— Threshold is exceeded (except for cache errors).
— A few other errors of the sort considered nonrecoverable are
present.
•
Disable cache(s) permanently if error threshold is exceeded.
•
Flush and re-enable those caches which have been marked as good.
•
Clear the error flags.
•
Perform Return from Exception or Interrupt (REI) to recover and
restart or continue the instruction stream for the following situations:
— Most INT54 errors.
— Those INT60 and INT54 errors which result in bad ECC written to a
memory location. (These errors can provide clues that the problem
is not memory related.)
— Machine check conditions where instruction retry is possible.
— Memory uncorrectable ECC error where page replacement is
possible and instruction retry is possible.
5–6 KA675/KA680/KA690 CPU System Maintenance
— Threshold exceeded (for cache errors only).
— Return from Subroutine (RSB) and return from all polled errors.
NOTE: The results of the VMS error handler may be preserved within the
operating system session (for example, disabling a cache) but not across
reboots.
Although the system can recover with cache disabled, the system
performance will be degraded, since access time increases as available cache
decreases.
5.2.3 VMS Error Logging and Event Log Entry Format
The VMS error handler for the kernel can generate six different entry
types, as shown in Table 5–3. All error entry types with the exception
of correctable ECC memory errors, are logged immediately.
Table 5–3: VMS Error Handler Entry Types
VMS Entry Type
Code
Description
EMB$C_MC
(002.)
Machine Check Exception
SCB Vector 4, IPL 1F
EMB$C_SE
(006.)
Soft Error Interrupt
Correctable ECC Memory Error
SCB Vector 54, IPL 1A
EMB$C_INT54
(026.)
Soft Error Interrupt
SCB Vector 54, IPL 1A
EMB$C_INT60
(027.)
Hard Error Interrupt 60
SCB Vector 60, IPL 1D
EMB$C_POLLED
(044.)
Polled Errors
No exception or interrupt generated by
hardware.
EMB$C_BUGCHECK
Fatal bugcheck
Bugcheck Types:
MACHINECHK
ASYNCWRTER
BADMCKCOD
INCONSTATE
UNXINTEXC
Each entry consists of a VMS header, a packet header, and one or more
subpackets (Figure 5–1). Entries can be of variable length based on the
number of subpackets within the entry. The FLAGS software register in
System Troubleshooting and Diagnostics
5–7
the packet header shows which subpackets are included within a given
entry.
Refer to Section 5.2.4 for actual examples of the error and event logs
described throughout this section.
Figure 5–1: Event Log Entry Format
00
31
VMS Header
Packet Revision
Packet
Header
SYSTAT
Subpacket Valid Flags
Subpacket 1
.
.
.
Subpacket n
MLO-007263
Machine check exception entries contain, at a minimum, a Machine Check
Stack Frame subpacket (Figure 5–2).
5–8 KA675/KA680/KA690 CPU System Maintenance
Figure 5–2: Machine Check Stack Frame Subpacket
24 23
31
08 07
16 15
00
00000018 (hex) byte count (not including this longword, PC or PSL)
AST
LVL
RN
xxxxxx
xx
Mode
Machine
Check Code
0.
4. ISTATE1
CPU ID
xxxxxxxx
INT. SYS register
8.
SAVEPC register
12.
VA register
16.
Q register
20.
Opcode
xxxxxxxx
V
R
xxxxxxxx
24. ISTATE2
PC
28.
PSL
32.
MLO-007264
INT54, INT60, Polled, and some Machine Check entries contain a processor
Register subpacket (Figure 5–3), which consists of some 40 plus hardware
registers.
System Troubleshooting and Diagnostics
5–9
Figure 5–3: Processor Register Subpacket
00
31
00
31
BPCR
(IPR D4)
0.
PAMODE
(IPR E7)
MMEPTE
(IPR E9)
MMESTS
92.
MMEADR
(IPR E8)
4.
VMAR
(IPR D0)
96.
8.
TBADR
(IPR EC)
100.
(IPR EA)
12.
PCADR
(IPR F2)
104.
PCSCR
(IPR 7C)
16.
BCEDIDX
(IPR A7)
108.
ICSR
(IPR D3)
20.
BCEDECC
(IPR A8)
112.
ECR
(IPR 7D)
24.
BCETIDX
(IPR A4)
116.
TBSTS
(IPR ED)
28.
BCETAG
(IPR A5)
120.
PCCTL
(IPR F8)
32.
MEAR
(2101.8040)
124.
PCSTS
(IPR F4)
36.
MOAMR
(2101.804C)
128.
CCTL
(IPR A0)
40.
CSEAR1 (2102.0008)
132.
BCEDSTS
(IPR A6)
44.
CSEAR2
(2102.000C)
136.
BCETSTS
(IPR A3)
48.
CIOEAR1 (2102.0010)
140.
MESR
(2101.8044)
52.
CIOEAR2
(2102.0014)
144.
MMCDSR
(2101.8048)
56.
CNEAR
(2102.0018)
148.
CESR
(2102.0000)
60.
CEFDAR
(IPR AB)
152.
CMCDSR
(2102.0004)
64.
NEOADR
(IPR B0)
156.
CEFSTS
(IPR AC)
68.
NEDATHI
(IPR B4)
160.
NESTS
(IPR AE)
72.
NEDATLO
(IPR B6)
164.
NEOCMD
(IPR B2)
76.
QBEAR
(2008.0008)
168.
NEICMD
DEAR
(2008.000C)
172.
(IPR B8)
80.
DSER
(2008.0004)
84.
CBTCR
(2014.0020)
88.
IPCR0 (2000.1F40) 176.
MLO-007265
NOTE: The byte count, although part of the stack frame, is not included in
the error log entry itself.
Bugcheck entries generated by the VMS kernel error handler include the
first 23 registers from the processor Register subpacket along with the Time
of Day Register (TODR) and other software context state.
Uncorrectable ECC memory error entries include a Memory subpacket
(Figure 5–4). The memory subpacket consists of MEMCON, which is a
5–10 KA675/KA680/KA690 CPU System Maintenance
software register containing the memory configuration and error status
used for FRU isolation, and MEMCONn, the hardware register that
matched the error address in MEAR.
Figure 5–4: Memory Subpacket for ECC Memory Errors
00
31
MEMCON
0.
MEMCONn (one longword from 2101.8000 - 2101.801C)
4.
MLO-007266
Correctable Memory Error entries have a Memory (Single-Bit Error) SBE
Reduction subpacket (Figure 5–5). This subpacket, unlike all others, is
of variable length. It consists solely of software registers from state
maintained by the error handler, as well as hardware state transformed
into a more usable format.
Figure 5–5: Memory SBE Reduction Subpacket (Correctable Memory
Errors)
31
Memory SBE Reduction Subpacket
00
CRD Entry Subpacket Header
CRD Entry #1
CRD Entry #2
.
.
.
CRD Entry n
Max n = 16
MLO-007267
The VMS error handler maintains a Correctable Read Data (CRD) buffer
internally within memory that is flushed asynchronously for high-level
events to the error log file. The CRD buffer and resultant error log entry
are maintained and organized as follows.
System Troubleshooting and Diagnostics
5–11
•
Each entry has a subpacket header (Figure 5–6) consisting of LOGGING
REASON, PAGE MAPOUT CNT, MEMCON, VALID ENTRY CNT,
and CURRENT ENTRY. MEMCON contains memory configuration
information, but no error status as is done for the Memory subpacket.
Figure 5–6: CRD Entry Subpacket Header
31
24 23
16 15
08 07
00
Logging Reason
0.
Page Mapout CNT
4.
MEMCON
8.
Valid Entry CNT
12.
Current Entry
16.
MLO-007268
•
Following the subpacket header are 1 to 16 fixed-length Memory CRD
Entries (Figure 5–7). The number of Memory CRD entries is shown in
VALID ENTRY CNT. The entry which caused the report to be generated
is in CURRENT ENTRY.
5–12 KA675/KA680/KA690 CPU System Maintenance
Figure 5–7: Correctable Read Data (CRD) Entry
31
24 23
16 15
08 07
00
Footprint
0.
Status
4.
CRD CNT
8.
Pages Marked Bad CNT
12.
First Event
16.
Last Event
24.
Lowest Address
32.
Highest Address
36.
MLO-007269
Each Memory CRD Entry represents one unique DRAM within the
memory subsystem. A unique set, bank, and syndrome are stored in
footprint to construct a unique ID for the DRAM.
Rather than logging an error for each occurrence of a single symbol
correctable ECC memory error, the VMS error handler maintains the
CRD buffer—it creates a Memory CRD Entry for new footprints and
updates an existing Memory CRD Entry for errors that occur within
the range specified by the ID in FOOTPRINT. This reduces the amount
of data logged overall without losing important information—errors are
logged per unique failure mode rather than on a per error basis.
Each Memory CRD entry consists of a FOOTPRINT, STATUS, CRD
CNT, PAGE MAPOUT CNT, FIRST EVENT, LAST EVENT, LOWEST
ADDRESS and HIGHEST ADDRESS.
FIRST EVENT, LAST EVENT, LOWEST ADDRESS and HIGHEST
ADDRESS are updated to show the range of time and addresses of
errors which have occurred for a DRAM. CRD CNT is simply the total
count per footprint. PAGE MAPOUT CNT is the number of pages that
have been marked bad for a particular DRAM.
System Troubleshooting and Diagnostics
5–13
STATUS contains a record of the failure mode status of a particular
DRAM over time. This in turn determines whether or not the CRD
buffer is logged. For the first occurrence of an error within a particular
DRAM, the memory location will be scrubbed (corrected read data is
read, then written back to the memory location) and CRD CNT will be
set to 1. Since most memory single-bit errors are transient due to alpha
particles, logging of the CRD buffer will not be done immediately for
the first occurrence of an error within a DRAM. The CRD buffer will,
however, be logged at the time of system shutdown (operator or crash
induced), or when a more severe memory subsystem error occurs.
If the FOOTPRINT/DRAM experiences another error (CRD CNT > 1),
VMS will set HARD SINGLE ADDRESS or MULTIPLE ADDRESSES
along with SCRUBBED in STATUS. Scrubbing is no longer performed;
instead, pages are marked bad. In this case, VMS will log the CRD
buffer immediately. The CRD Buffer will also be logged immediately
if PAGE MAPOUT THRESHOLD EXCEEDED is set in SYSTAT as a
result of pages being marked bad. The threshold is reached if more
than one page per Mbyte of system memory is marked bad.
NOTE: CURRENT ENTRY will be zero in the Memory SBE Reduction
subpacket header if the CRD buffer was logged, not as a result of
a HARD SINGLE ADDRESS or MULTIPLE ADDRESSES error in
STATUS, but as a result of a memory uncorrectable ECC error shown as
RELATED ERROR, or as a result of CRD BUFFER FULL or SYSTEM
SHUTDOWN, all of which are shown under LOGGING REASON.
5.2.4 VMS Event Record Translation
The kernel error log entries are translated from binary to ASCII using the
ANALYZE/ERROR command. To invoke the error log utility, enter the DCL
command ANALYZE/ERROR_LOG.
Format:
ANALYZE_ERROR_LOG [/qualifier(s)] [file-spec] [,...]
Example:
$ ANALYZE/ERROR_LOG/INCLUDE=(CPU,MEMORY)/SINCE=TODAY
The error log utility translates the entry into the traditional three-column
format. The first column shows the register mnemonics, the second column
depicts the data in hex, and the last column shows the actual English
translations.
5–14 KA675/KA680/KA690 CPU System Maintenance
As in the above example, the VMS error handler also provides support for
the /INCLUDE qualifier, such that CPU and MEMORY error entries can
be selectively translated.
Since most kernel errors are bounded to either the processor module/system
board or memory modules, the individual error flags and fields are not
covered by the service theory. Although these flags are generally not
required to diagnose a system to the FRU (Field Replaceable Unit), this
information can be useful for component isolation.
ERF bit to text translation highlights all error flags that are set, and other
significant state—these are displayed in capital letters in the third column.
Otherwise, nothing is shown in the translation column. The translation
rules also have qualifiers such that if the setting of an error flag causes
other registers to be latched, the other registers will be translated as well.
For example, if a memory ECC error occurs, the syndrome and error address
fields will be latched as well. If such a field is valid, the translation will
be shown (e.g. MEMORY ERROR ADDRESS); otherwise, no translation is
provided.
5.2.5 Interpreting CPU Faults Using ANALYZE/ERROR
If the following three conditions are satisfied, the most likely FRU is the
CPU module. Example 5–1 shows an abbreviated error log with numbers
to highlight the key registers.
No memory subpacket is listed in the third column of the FLAGS
register.
CESR register bit <09>, CP2 IO Error, is equal to zero in the KA675
/KA680/KA690 Register Subpacket.
DSER register bits <07>, Q22 Bus NXM, <05>, Q22 Bus Device Parity
Error, or <02>, Q-22 Bus No Grant, are equal to zero in the KA675
/KA680/KA690 Register Subpacket.
The FLAGS register is located in the packet header, which immediately
follows the system identification header; the CESR and DSER registers are
listed under the KA675/KA680/KA690 Register Subpacket.
CPU errors will increment a VMS global counter, which can be viewed using
the DCL command SHOW ERROR, as shown in Example 5–2.
To determine if any resources have been disabled, for example, if cache has
been disabled for the duration of the VMS session, examine the flags for
the SYSTAT register in the packet header.
In Example 5–1, a translation buffer data parity error latched in the TBSTS
register caused a machine check exception error.
System Troubleshooting and Diagnostics
5–15
Example 5–1: Error Log Entry Indicating CPU Error
V A X / V M S
SYSTEM ERROR REPORT
******************************* ENTRY
ERROR SEQUENCE 11.
DATE/TIME 27-SEP-1991 14:40:10.85
SYSTEM UPTIME: 0 DAYS 00:12:12
SCS NODE: OMEGA1
COMPILED 14-JAN-1992 18:55:52
PAGE
1.
1. *******************************
LOGGED ON:
SID 13000202
SYS_TYPE 01390601
VAX/VMS V5.5-1
MACHINE CHECK KA680-A CPU FW REV# 2. CONSOLE FW REV# 3.9
REVISION
00000000
SYSTAT
00000001
ATTEMPTING RECOVERY
FLAGS
00000003
machine check stack frame
KA680 subpacket
STACK FRAME SUBPACKET
ISTATE_1
80050000
MACHINE CHECK FAULT CODE = 05(x)
Current AST level = 4(X)
ASYNCHRONOUS HARDWARE ERROR
.
.
.
PSL
04140001
c-bit
executing on interrupt stack
PSL previous mode = kernel
PSL current mode = kernel
first part done set
KA680 REGISTER SUBPACKET
BPCR
.
.
.
TBSTS
ECC80024
800001D3
LOCK SET
TRANSLATION BUFFER DATA PARITY ERROR
em_latch invalid
s5 command = 1D(X)
valid Ibox specifier ref. error stored
.
.
.
CESR
.
.
.
DSER
.
.
.
IPCR0
00000000
00000000
00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
5–16 KA675/KA680/KA690 CPU System Maintenance
NOTE: Ownership (O-bit) memory correctable or fatal errors (MESR <04>
or MESR <03> of the processor Register Subpacket set equal to 1) are
processor module errors, NOT memory errors.
Example 5–2: SHOW ERROR Display Using VMS
$ SHOW ERROR
Device
CPU
MEMORY
PAB0:
PAA0:
PTA0:
RTA2:
Error Count
1
1
1
1
1
1
$
5.2.6 Interpreting Memory Faults Using ANALYZE/ERROR
If "memory subpacket" or "memory sbe reduction subpacket" is listed in the
third column of the FLAGS register, there is a problem with one or more
of the memory modules, CPU module, or backplane.
•
The "memory subpacket" message indicates an uncorrectable ECC
error. Refer to Section 5.2.6.1 for instructions in isolating uncorrectable
ECC error problems.
•
The "memory sbe reduction subpacket" message indicates correctable
ECC errors. Refer to Section 5.2.6.2 for instructions in isolating
correctable ECC error problems.
NOTE: The memory fault interpretation procedures work only if the memory
modules have been properly installed and configured. For example, memory
modules should start in backplane slot 4 (next to the processor module in
slot 5) and proceed to slot 1 with no gaps.
NOTE: Although the VMS error handler has built in features to aid Services
in memory repair, good judgment is needed by the Service Engineer. It is
essential to understand that in many, if not most cases, correctable ECC
errors are transient in nature. No amount of repair will fix them, as
generally there is nothing to be fixed.
Memory modules can represent a great expense to the Corporation when they
are sent back to Repair with no errors. If one disagrees with the strategy
System Troubleshooting and Diagnostics
5–17
in this section or has questions or suggestions, please contact Corporate
Support.
5.2.6.1 Uncorrectable ECC Errors
Refer to Example 5–3, which provides an abbreviated error log for
uncorrectable ECC errors.
For uncorrectable ECC errors, a memory subpacket will be logged as
indicated by "memory subpacket" listed in the third column of the FLAGS
software register ( ). Also, the hardware register MESR <11> ( ) of the
processor Register Subpacket will be set equal to 1, and MEAR will latch
the error address ( ).
Examine the MEMCON software register ( ) under the memory subpacket.
The MEMCON register provides memory configuration information and a
MEMORY ERROR STATUS buffer ( ) that points to the memory module(s)
that is the most likely FRU.
Replace the indicated memory module. In Example 5–3 the most likely
FRU is indicated as memory module #2, slot 3.
The VMS error handler will mark each page bad and attempt page
replacement, indicated in SYSTAT ( ). The DCL command SHOW
MEMORY (Example 5–4) will also indicate the result of VMS page
replacement.
Uncorrectable memory errors will increment the VMS global counter, which
can be viewed using the DCL command SHOW ERROR.
NOTE: If register MESR <11> was set equal to 1, but MESR <19:12>
syndrome equals 07, no memory subpacket will be logged as a result of
incorrect check bits written to memory because of an NDAL bus parity
error detected by the NMC. In short, this indicates a problem with the CPU
module, not memory. There should be a previous entry with MESR <22>,
NDAL Data Parity Error set equal to 1.
NOTE: One type of uncorrectable ECC error, that due to a ‘‘disown write’’,
will result in a CRD entry like those for correctable ECC errors.
Example 5–3: Error Log Entry Indicating Uncorrectable ECC Error
Example 5–3 (continued on next page)
5–18 KA675/KA680/KA690 CPU System Maintenance
Example 5–3 (Cont.): Error Log Entry Indicating Uncorrectable ECC
Error
V A X / V M S
SYSTEM ERROR REPORT
******************************* ENTRY
ERROR SEQUENCE 2.
DATE/TIME 4-OCT-1991 09:14:29.86
SYSTEM UPTIME: 0 DAYS 00:01:39
SCS NODE: OMEGA1
INT54 ERROR KA680-A
REVISION
SYSTAT
CPU FW REV# 2.
00000000
00000601
COMPILED 6-NOV-1991 10:16:49
PAGE 25.
13. *******************************
LOGGED ON:
SID 13000202
SYS_TYPE 01390601
VAX/VMS V5.5-1
CONSOLE FW REV# 3.9
ATTEMPTING RECOVERY
PAGE MARKED BAD
PAGE REPLACED
FLAGS
00000006
memory subpacket
KA680 subpacket
KA680 REGISTER SUBPACKET
BPCR
.
.
.
MESR
ECC80000
80006800
UNCORRECTABLE MEMORY ECC ERROR
ERROR SUMMARY
MEMORY ERROR SYNDROME = 06(X)
.
.
.
MEAR
02FFDC00
main memory error address = 0BFF7000
ndal commander id = 00(X)
.
.
.
IPCR0
00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
MEMORY SUBPACKET
MEMCON
0357E53F
MEMORY CONFIGURATION:
_sets enabled = 00111111
MS690-BA MEMORY MODULE # 1. 32MB SLOT 4
MS690-BA MEMORY MODULE # 2. 32MB SLOT 3
MS690-DA MEMORY MODULE # 3. 128MB SLOT 2
_total memory = 192MB
Example 5–3 (continued on next page)
System Troubleshooting and Diagnostics
5–19
Example 5–3 (Cont.): Error Log Entry Indicating Uncorrectable ECC
Error
MEMORY ERROR STATUS:
MEMORY MODULE #2 SLOT 3
Bank = 00(X)
Set = 03(X)
MEMCON3
8B000003
64 bit mode
Base address valid
RAM size = 1MB
base address = 0B(X)
Example 5–4: SHOW MEMORY Display Under VMS
$ SHOW MEMORY
System Memory Resources on 21-FEB-1992 05:58:52.58
Physical Memory Usage (pages):
Main Memory (128.00Mb)
Total
262144
Free
224527
In Use
28759
Modified
8858
Total
1
Dynamic
1
I/O Errors
0
Static
0
Slot Usage (slots):
Process Entry Slots
Balance Set Slots
Total
360
324
Free
347
313
Resident
13
11
Swapped
0
0
Fixed-Size Pool Areas (packets):
Small Packet (SRP) List
I/O Request Packet (IRP) List
Large Packet (LRP) List
Total
3067
2263
87
Free
2724
2070
61
In Use
343
193
26
Size
128
176
1856
Total
1037824
1468416
Free
503920
561584
In Use
533904
906832
Largest
473184
560624
Free
300000
Reservable
266070
Total
300000
Bad Pages
Dynamic Memory Usage (bytes):
Nonpaged Dynamic Memory
Paged Dynamic Memory
Paging File Usage (pages):
DISK$VMS054-0:[SYS0.SYSEXE]PAGEFILE.SYS
Of the physical pages in use, 24120 pages are permanently allocated to VMS.
$
Using the VMS command ANALYZE/SYSTEM, you can associated a page
that had been replaced (Bad Pages in SHOW MEMORY display) with the
physical address in memory.
In Example 5–5, 5ffb8 (under the Page Frame Number (PFN) coloumn) is
identified as the single page that has been replaced. The command EVAL
5ffb8 * 200 converts the PFN to a physical page address. The result is
0bff7000, which is the MEAR address translated in Example 5–3. (Bits
<8:0> of the addresses may differ since the page address from EVAL always
shows bits <8:0> as 0.
5–20 KA675/KA680/KA690 CPU System Maintenance
Example 5–5: Using ANALYZE/SYSTEM to Check the Physical Address
in Memory for a Replaced Page
$ ANALYZE/SYSTEM
VAX/VMS System analyzer
SDA> SHOW PFN /BAD
Bad page list
------------Count:
Lolimit:
High limit:
PFN
---0005FFB8
1
-1
1073741824
PTE ADDRESS
----------00000000
BAK
-------00000000
REFCNT
-----0
FLINK
BLINK
--------00000000 00000000
TYPE
---------20 PROCESS
STATE
---------02 BADLIST
SDA> EVAL 5ffb8 * 200
Hex = 0BFF7000
Decimal = 201289728
SDA> EXIT
$
5.2.6.2 Correctable ECC Errors
Refer to Example 5–6, which provides an error log showing correctable ECC
errors.
For correctable ECC errors, a Single-Bit Error (SBE) Memory Subpacket
will be logged as indicated by "memory sbe reduction subpacket" listed in
the third column of the FLAGS software register ( ).
The Memory SBE Reduction Subpacket header contains a CURRENT
ENTRY register ( ) that displays the number of the Memory CRD Entry
that caused the error notification. If CURRENT ENTRY > 0, examine
which bits are set in the STATUS register ( ) for this entry—GENERATE
REPORT should be set.
NOTE: If CURRENT ENTRY = 0, then the entry was logged for something
other than a single-bit memory correctable error Footprint. You will need to
examine all of the Memory CRD Entries and Footprints to try to determine
the likely FRU.
Check for the following:
•
SCRUBBED ( )—If SCRUBBED is the only bit set in the STATUS
register, memory modules should NOT generally be replaced.
The kernel performs memory scrubbing of DRAM memory cells that
may flip due to transient alpha particles. Scrubbing simply reads the
corrected data and writes it back to the memory location. Returning
memory modules that only have SCRUBBED set in STATUS will cost
System Troubleshooting and Diagnostics
5–21
the corporation money, since the repair centers will generally not find
a problem.
•
HARD SINGLE ADDRESS ( )—If the second occurrence of an error
within a footprint is at the same address (LOWEST ADDRESS =
HIGHEST ADDRESS ( )), then HARD SINGLE ADDRESS will be set
in STATUS along with SCRUBBED. Scrubbing will not be tried after
the first occurrence of any error within a particular footprint. The page
will be marked bad by VMS.
Unlike uncorrectable ECC errors, the error handling code cannot
indicate if the page has been replaced. To get some idea, use DCL
command, SHOW MEMORY. If the page mapout threshold has not
been reached ("PAGE MAPOUT THRESHOLD EXCEEDED" is not set
in SYSTAT packet header register ( )), the system should be restarted
at a convenient time to allow the power-up self-test and ROM-based
diagnostics to map out these pages. This can be done by entering
TEST 0 at the console prompt, running an extended script TEST A9,
or by powering down then powering up the system. In all cases, the
diagnostic code will mark the page bad for hard single address errors,
as well as any uncorrectable ECC error by default.
If there are many locations affected by hard single-cell errors, on the
order of one or more pages per MB of system memory, the memory
module should be replaced. The console command SHOW MEMORY
will indicate the number of bad pages per module. For example, if the
system contains 64 MB of main memory and there are 64 or more bad
pages, the affected memory should be replaced.
NOTE: Under VMS, the page mapout threshold is calculated
automatically. If "PAGE MAPOUT THRESHOLD EXCEEDED" is set
in SYSTAT ( ), the failing memory module should be replaced.
In cases of a new memory module used for repair or as part of system
installation, one may elect to replace the module rather than having
diagnostics map them out, even if the threshold has not been reached
for hard single-address errors.
•
MULTIPLE ADDRESSES ( )—If the second occurrence of an error
within a footprint is at a different address (LOWEST ADDRESS not
equal to HIGHEST ADDRESS ( ), MULTIPLE ADDRESSES will be
set in STATUS along with SCRUBBED. Scrubbing will not be attempted
for this situation. In most cases, the offending memory module should
be replaced regardless of the page mapout threshold.
If CRD BUFFER FULL is set in LOGGING REASON ( ) (located in the
subpacket header) or PAGE MAPOUT THRESHOLD EXCEEDED is set in
5–22 KA675/KA680/KA690 CPU System Maintenance
SYSTAT ( ), the offending memory module should be replaced regardless
of any thresholds.
For all cases (except when SCRUBBED is the only flag set in STATUS)
isolate the offending memory by examining the translation in FOOTPRINT
called MEMORY ERROR STATUS ( ): The memory module is identified
by its backplane position. In Example 5–6, memory module #3, slot 2, is
identified as the failing module.
The Memory SBE Reduction Subpacket header translates the MEMCON
register ( ) for memory subsystem configuration information.
Unlike uncorrectable memory and CPU errors, the VMS global counter is
not incremented for correctable ECC errors.
NOTE: If footprints are being generated for more than one memory module,
especially if they all have the same bit in error, the processor module,
backplane, or other component may be the cause.
NOTE: One type of uncorrectable ECC error, that due to a ‘‘disown write’’,
will result in a CRD entry like those for correctable ECC errors. The
FOOTPRINT longword for this entry contains the message ‘‘Uncorrectable
ECC errors due to disown write’’. The failing module should be replaced for
this error.
System Troubleshooting and Diagnostics
5–23
Example 5–6: Error Log Entry Indicating Correctable ECC Error
V A X / V M S
SYSTEM ERROR REPORT
COMPILED 21-NOV-1991 16:55:58
PAGE
1.
1. *******************************
LOGGED ON:
SID 13001401
SYS_TYPE 01390601
******************************* ENTRY
ERROR SEQUENCE 2.
DATE/TIME 27-SEP-1991 09:51:13.98
SYSTEM UPTIME: 0 DAYS 00:05:06
SCS NODE: OMEGA1
CORRECTABLE MEMORY ERROR KA680-A
REVISION
00000000
SYSTAT
00000040
VAX/VMS V5.5-1
CPU FW REV# 1.
CONSOLE FW REV# 3.9
MEMORY SOFT ERROR LOGGING DISABLED
FLAGS
00000008
memory sbe reduction subpacket
MEMORY SBE REDUCTION SUBPACKET
LOGGING REASON
00000001
NORMAL REPORT
PAGE MAPOUT CNT 00000003
MEMCON
0357E53F
MEMORY CONFIGURATION:
_sets enabled = 00111111
MS690-BA MEMORY MODULE # 1. 32MB SLOT 4
MS690-BA MEMORY MODULE # 2. 32MB SLOT 3
MS690-DA MEMORY MODULE # 3. 128MB SLOT 2
_total memory = 192MB
VALID ENTRY CNT 00000003
3.
CURRENT ENTRY
00000003
3.
MEMORY CRD ENTRY 1.
FOOTPRINT
00000373
MEMORY ERROR STATUS:
_MEMORY MODULE #2 SLOT 3
_set = 3.
_bank = 0.
ECC SYNDROME = 73(X)
_CORRECTED DATA BIT = 0.
STATUS
00000010
CRD CNT
00000001
scrubbed
1.
PAGE MAPOUT CNT 00000000
0.
FIRST EVENT
0D3E26E0
0094F438
LAST EVENT
0D3E26E0
0094F438
27-SEP-1991 09:50:13.07
27-SEP-1991 09:50:13.07
LOWEST ADDRESS 0BFF4000
HIGHEST ADDRESS 0BFF4000
Example 5–6 (continued on next page)
5–24 KA675/KA680/KA690 CPU System Maintenance
Example 5–6 (Cont.): Error Log Entry Indicating Correctable ECC Error
MEMORY CRD ENTRY 2.
FOOTPRINT
0000001C
MEMORY ERROR STATUS:
_MEMORY MODULE #1 SLOT 4
_set = 0.
_bank = 0.
ECC SYNDROME = 1C(X)
_CORRECTED DATA BIT = 4.
STATUS
00000019
PAGE MARKED BAD
HARD SINGLE ADDRESS
scrubbed
CRD CNT
00000002
2.
PAGE MAPOUT CNT 00000001
1.
FIRST EVENT
0FFF1BA0
0094F438
LAST EVENT
0FFF1BA0
0094F438
27-SEP-1991 09:50:17.69
27-SEP-1991 09:50:17.69
LOWEST ADDRESS 0057FD44
HIGHEST ADDRESS 0057FD44
MEMORY CRD ENTRY 3.
FOOTPRINT
0000050D
STATUS
00000055
MEMORY ERROR STATUS: _MEMORY MODULE #3 SLOT 2
_set = 5.
_bank = 0.
ECC SYNDROME = 0D(X)
_CORRECTED DATA BIT = 15.
PAGE MARKED BAD
MULTIPLE ADDRESSES
scrubbed
GENERATE REPORT
CRD CNT
00000003
3.
PAGE MAPOUT CNT 00000002
2.
FIRST EVENT
122F1B00
0094F438
LAST EVENT
122F1B00
0094F438
27-SEP-1991 09:50:21.36
LOWEST ADDRESS 08C72140
HIGHEST ADDRESS 08E43B28
ANAL/ERR/OUT=CRD CRD.ZPD
27-SEP-1991 09:50:21.36
System Troubleshooting and Diagnostics
5–25
NOTE: Ownership (O-bit) memory correctable or fatal errors (MESR <04>
or MESR <03> of the processor Register Subpacket set equal to 1) are
processor module errors, NOT memory errors.
5.2.7 Interpreting System Bus Faults Using
ANALYZE/ERROR
If hardware register CESR <09> ( ) and CQBIC hardware register DSER
<07>, <05>, or <02> ( ) is set equal to 1, there may be a problem with the
Q–bus or Q–bus option.
When CESR <09> is set equal to 1, examine the hardware register
CIOEAR2 ( ) to determine the address of the offending option.
Example 5–7 provides an error log showing a faulty Q–bus option. The
CIOEAR2 error register indicates the first UQSSP controller as the
offending address.
5–26 KA675/KA680/KA690 CPU System Maintenance
Example 5–7: Error Log Entry Indicating Q-Bus Error
V A X / V M S
SYSTEM ERROR REPORT
******************************* ENTRY
ERROR SEQUENCE 1852.
DATE/TIME 20-NOV-1991 14:26:11.14
SYSTEM UPTIME: 12 DAYS 20:04:19
SCS NODE:
COMPILED 20-NOV-1991 14:28:13
PAGE
1.
75. *******************************
LOGGED ON:
SID 13000202
SYS_TYPE 01410601
VAX/VMS V5.5-1
MACHINE CHECK KA680-A CPU FW REV# 2. CONSOLE FW REV# 4.1
REVISION
00000000
SYSTAT
00000001
ATTEMPTING RECOVERY
FLAGS
00000003
machine check stack frame
KA680 subpacket
STACK FRAME SUBPACKET
ISTATE_1
.
.
.
PSL
80060000
03C00000
PSL previous mode = user
PSL current mode = user
first part done set
KA680 REGISTER SUBPACKET
BPCR
.
.
.
CESR
ECC80024
80000200
CP2 IO ERROR
ERROR SUMMARY
.
.
.
DSER
00000080
Q-22 BUS NXM
.
.
.
CIOEAR2
00001468
cp2 IO error address = 20001468
NDAL commander id (cp2 transac) = 0(X)
.
.
.
IPCR0
00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
ANAL/ERR/OUT=QBUS QBUS.ZPD
System Troubleshooting and Diagnostics
5–27
5.2.8 Interpreting DMA
ANALYZE/ERROR
Host Transaction Faults Using
Some kernel errors may result in two or more entries being logged. If
the SHAC DSSI adapters or the SGEC Ethernet controller or other CDAL
device (residing on the processor module) encounter host main memory
uncorrectable ECC errors, main memory NXMs or CDAL parity errors or
timeouts, more than one entry results. Usually there will be one Polled
Error entry logged by the host, and one or more Device Attention and other
assorted entries logged by the device drivers.
In these cases the processor module or one of the four memory modules
are the most likely cause of the errors. Therefore, it is essential to analyze
Polled Error entries, since a polled entry usually represents the source of
the error versus other entries, which are simply aftereffects of the original
error.
Example 5–8 provides an abbreviated error log for a polled error.
Example 5–9 provides an example of a device attention entry.
Example 5–8: Error Log Entry Indicating Polled Error
V A X / V M S
SYSTEM ERROR REPORT
******************************* ENTRY
ERROR SEQUENCE 15.
DATE/TIME 17-FEB-1992 05:22:00.90
SYSTEM UPTIME: 0 DAYS 00:27:48
SCS NODE:
POLLED ERROR KA680-A CPU FW REV# 2.
REVISION
00000000
SYSTAT
00000001
COMPILED 17-FEB-1992 05:32:21
PAGE
1.
2. *******************************
LOGGED ON:
SID 13000202
SYS_TYPE 01430701
VAX/VMS V5.5-1
CONSOLE FW REV# 4.3
ATTEMPTING RECOVERY
FLAGS
00000006
memory subpacket
KA680 subpacket
KA680 REGISTER SUBPACKET
Example 5–8 (continued on next page)
5–28 KA675/KA680/KA690 CPU System Maintenance
Example 5–8 (Cont.): Error Log Entry Indicating Polled Error
BPCR
.
.
.
MESR
ECC80024
8001B800
UNCORRECTABLE MEMORY ECC ERROR
ERROR SUMMARY
MEMORY ERROR SYNDROME = 1B(X)
.
.
.
MEAR
50000410
main memory error address = 00001040
ndal commander id = 05(X)
.
.
.
IPCR0
00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
MEMORY SUBPACKET
MEMCON
0057E53F
MEMORY CONFIGURATION:
_sets enabled = 00111111
MS690-BA MEMORY MODULE # 1. 32MB SLOT 4
MS690-BA MEMORY MODULE # 2. 32MB SLOT 3
MS690-DA MEMORY MODULE # 3. 128MB SLOT 2
_total memory = 192MB
MEMORY ERROR STATUS:
MEMORY MODULE #3 SLOT 2
Bank = 00(X)
Set = 00(X)
MEMCON0
80000003
64 bit mode
Base address valid
RAM size = 1MB
base address = 00(X)
ANAL/ERR/OUT=TB1 TB1.ZPD
System Troubleshooting and Diagnostics
5–29
Example 5–9: Device Attention Entry
V A X / V M S
SYSTEM ERROR REPORT
******************************* ENTRY
ERROR SEQUENCE 15.
DATE/TIME 17-FEB-1992 05:22:00.90
SYSTEM UPTIME: 0 DAYS 00:27:48
SCS NODE:
DEVICE ATTENTION
KA680-A
COMPILED 17-FEB-1992 05:32:21
PAGE
1.
2. *******************************
LOGGED ON:
SID 13000202
SYS_TYPE 01430701
VAX/VMS V5.5-1
CPU FW REV# 2.
CONSOLE FW REV# 4.3
DSSI SUB-SYSTEM, PAB0: - PORT WILL BE RE-STARTED
PORT TIMEOUT, DRIVER RESETTING PORT
CNF
03060022
MAINTENANCE ID = 0022(X)
FIRMWARE REVISION = 06(X)
HARDWARE REVISION = 03(X)
PMCSR
PSR
00000000
80010000
MAINTENANCE ERROR
SHARED HOST MEMORY ERROR
PFAR
40001044
PESR
00010000
PPR
00000000
APPROX HOST ADDR 40001044(X)
CPDAL BUS ERROR
NODE #0.
0. BYTE INTERNAL BUFFER
16. NODES MAXIMUM
UCB$B_ERTCNT
2C
UCB$B_ERTMAX
32
44. RETRIES REMAINING
50. RETRIES ALLOWABLE
UCB$L_CHAR
0C450000
SHARABLE
AVAILABLE
ERROR LOGGING
CAPABLE OF INPUT
CAPABLE OF OUTPUT
UCB$W_STS
0010
UCB$W_ERRCNT
0007
ONLINE
7. ERRORS THIS UNIT
ANAL/ERR/ENTRY=(ST:2,END:3)/OUT=POLL_SHM
5.2.9 VAXsimPLUS and System-Initiated Call Logging (SICL)
Support
VAX 4000 systems use Symptom Directed Diagnosis (SDD) tools primarily
for notification. The VAX System Integrity Monitor Plus (VAXsimPLUS)
interactive reporting tool triggers notification for high-level events recorded
in SYSTAT and LOGGING REASON.
5–30 KA675/KA680/KA690 CPU System Maintenance
The VAXsimPLUS monitor simply parses for a handful of SYSTAT flags
and LOGGING reason codes. The VAXsimPLUS monitor display is updated
and triggering occurs if the threshold has been reached. Some flags have
a threshold of one; for example, SYSTAT <08> ERROR THRESHOLD
EXCEEDED will trigger VAXsimPLUS upon the first occurrence, since at
least three errors would have already occurred and been handled by VMS.
A particular event may cause only one triggering per VMS session; others
will trigger any time an event occurs within the VMS session; and others
will trigger if a threshold of 2 is reached within a rolling 24 hour window.
Table 5–4 lists the conditions that will trigger VAXsimPLUS notification
and updating. Figure 5–8 shows the flow for the VAXsimPLUS monitor
trigger. The entries ultimately are classified as either hard or soft. Errors
that require corrective maintenance are classified as hard; while errors
potentially requiring corrective maintenance are classified as soft.
Table 5–4: Conditions That Trigger VAXsimPLUS Notification and
Updating
Condition
Description
SYSTAT <00> = 1
"Attempting recovery"
SYSTAT <00> = 0
"Full recovery or retry not possible"
SYSTAT <08> = 1
"Error threshold exceeded"
SYSTAT <09> = 1
"Page marked bad for uncorrectable ECC error in main
memory"
SYSTAT <11> = 1
"Page mapout threshold for single bit ECC errors in main
memory exceeded"
LOGGING REASON <3:0> = 1
"Memory CRD buffer full"
LOGGING REASON <3:0> = 2
"Generate report as a result of hard single address or
multiple address DRAM memory fault"
LOGGING REASON <3:0> = 0,
3, 5–F
"Illegal LOGGING REASON"
LOGGING REASON <3:0> = 4
"System Shutdown"
System Troubleshooting and Diagnostics
5–31
Figure 5–8: Trigger Flow for the VAXsimPLUS Monitor
Entry type received
(see table 5-3)
Y
Y
LOGGING REASON
<03:00>=2?
N
EMB$C_SE?
(Soft Error Interrupt)
Y
Y
[1s]
[1a]
SYSTAT<09>=1?
N
N
Y
Y
Hard Trigger
SYSTAT<09>=1?
[1s]
SYSTAT<08>=1?
[1a]
N
N
Y
LOGGING REASON
<03:00>=1?
Y
Soft Trigger
[1a]
SYSTAT<00>=1?
[1a]
N
LOGGING REASON
<03:00>=4?
N
N
Y
[1a] Illegal
[2w]
SYSTAT<00>=1?
MLO-008656
VAXsimPLUS triggering notifies the customer and Services using three
message types: HARD, SOFT and SICL Service Request. Each message
contains the single STARS article theory number, as well as the SYSTAT
or LOGGING REASON state. In addition, the SICL Service Request will
have a Merged Error Log (MEL) datafile appended.
5–32 KA675/KA680/KA690 CPU System Maintenance
Figure 5–9 shows the five VAXsimPLUS monitor screen displays. Table 5–5
describes provides a brief explanation of for each of the five levels of screen
displays.
Table 5–5: Five-Level VAXsimPLUS Monitor Screen Display
Level
Explanation
System
The system level screen provides one box for each system
being analyzed (in Figure 5–9 a single system is being
analyzed). As with each screen level, the number of
reported errors is displayed in the box and the boxes blink
when the error thresholds are reached.
Subsystem
The subsystem level screen provides separate boxes for the
kernel and node information. Other boxes that may be
displayed are bus, disk, and tape.
Unit
The unit level screen provides a box for the kernel. If the
subsystem has more than one unit or device with errors,
those will be displayed as well.
Error Class
The error class level screen provides a box for both hard
and soft errors.
Error Detail
Two error detail level screens (hard and soft) provide
the number of reported errors along with a brief error
description.
System Troubleshooting and Diagnostics
5–33
Figure 5–9: Five-Level VAXsimPLUS Monitor Display
1
2
Since: 14-APR-1992 05:31 Margin: 15 Clipping: On
AB1X
Before: X-XXX-XXXX XX:XX Depth: 25 Regis: Off
Kernel
3
(Systems)
1
AB1X
3
Node Info
1
2
3
AB1X Kernel
4
AB1X Kernel AB1X$Kernel (NVAX4000)
AB1X$Kernel
3
1
Soft
2
1
Hard
1
2
5
AB1X Kernel AB1X$Kernel (NVAX4000) Soft
Count: Explanation
1: MCHK-PCache Rd Err (PCache Enabled)
1: Tag Store Copy Parity Error (1st half)
MLO-007270
Once notification occurs, the service engineer should examine the error log
file (after using the ANALYZE/ERROR command) or read the appended
Merged Error Log (MEL) file in the SICL service request message. (The
MEL file is encrypted, refer to Section 5.2.9.1 for instructions converting
5–34 KA675/KA680/KA690 CPU System Maintenance
these files.) Using the theory of interpretation provided in the previous
sections, you can manually interpret the error logs.
NOTE: The interpretation theory provided in this manual is also a STARS
article and can be accessed via the Decoder Kit.
In summary, a service engineer should use VAXsimPLUS notification as
follows:
1. Make sure all four message types are sent to the Field and System
accounts.
2. Log into the Field or System account.
3. Read mail (look for the SICL service request message with its appended
MEL file).
4. Convert the encrypted MEL file and use the theory provided in this
manual to interpret the error log file.
5.2.9.1 Converting the SICL Service Request MEL File
Use the following procedure to convert the encrypted MEL file that is
appended to the SICL service request message. Example 5–10 shows a
sample SICL service request message and appended MEL file.
1. Extract the SICL mail message from mail.
2. Edit the extracted file to obtain the appended MEL file. The MEL file
is the encrypted code that appears between the rows of asterisks and
the the words SICL and end.
3. Convert the encrypted code to a binary file using the VAXsimPLUS
decode command file as follows:
$ MCR SDD$EXE:FMGR$SICL_DECODE [MEL filename] [binary
filename]
4. Use the ANALYZE/ERROR command to produce an error log entry.
$ ANALYZE/ERROR [binary filename]
System Troubleshooting and Diagnostics
5–35
Example 5–10: SICL Service Request with Appended MEL File
From: AB1X::SDD$MANAGER
"VAXsimPLUS Message" 15-APR-1992 10:29:21.05
To: SYSTEM
CC:
Subj: SDD T2.0 Service Request - Analysis:[30B01.200]
********************************************************************************
VAXsimPLUS Notification Message
VAXsimPLUS has detected that the following device needs attention:
DEVICE:
NODE:
SYSTEM SERIAL NUMBER:
SYSTEM TYPE:
AB1X$KERNEL (NVAX4000)
AB1X
KA136H1520
VAX 4000-600
VAXsimPLUS Diagnosis Information
Attn:
Field Service
Device:
Count:
AB1X$KERNEL (NVAX4000)
1.
Theory:
[30B01.200]
Evidence:
Urgent action required - AB1X$KERNEL Hard error(s):
SYSTAT 9 = 1 - Page Marked Bad For Uncorrectable ECC Error In
Main Memory
********************************************************************************
%% SDD$PROFILE is defined to be NONE, no Customer Profile included in message %%
********************************************************************************
SICL
134
M @( $_O_ 0=# 0
A$24U)3$\@(
% @ G!::G+Y*5
M @ 034N-2U-,2 7
&0\
@ !P
[email protected]
: 0
"<<
M !\F>]_"
( %/,%$P
# R0 R.P
\%31!03 !P @ !
M (H
#0 0" /S__S#X__\A !
F 6 /CA"0
(P0
M"A(
%\
[P
0
’@[email protected] ’
@%.^!0
M
($+<]P ,12 P P
, "
S ,13
[email protected]
\
(
?Y#P(% " !_D/ @4 (
end
********************************************************************************
5.2.9.2 VAXsimPLUS Installation Tips
When installing VAXsimPLUS, the system will prompt you for information.
You will need to know the serial number and system model number for the
system on which you are installing VAXsimPLUS. The serial number is
located on the front of the chassis at the bottom and to the left (the front
door must be open). The system model number is attached to the outside
of the door.
Also, if the system does not have dialout capability, you should answer
no when asked if you want to enable SICL—if you enter yes, the system
will attempt to send mail via DSNLink resulting in error messages.
After VAXsimPLUS is installed you can activate SICL and customize
5–36 KA675/KA680/KA690 CPU System Maintenance
the VAXsimPLUS mailing lists so that SICL messages are sent to an
appropriate destination(s).
5.2.9.3 VAXsimPLUS Post-Installation Tips
Once VAXsimPLUS is installed, you can set up mailing lists to direct
VAXsimPLUS messages to the appropriate destinations. If the system has
no dailout capability, SICL messages should be directed to the System and
/or Field account—this is good practice for systems with dialout and service
center support as well.
In the example that follows, the four types of mailing lists are displayed
and System and Field accounts are added to the all four mailing lists using
VAXSIM/FAULT_MANAGER commands (note that the commands can be
abbreviated).
$ VAXSIM/FAULT SHOW MAIL
-- FSE mailing list -FIELD
-- CUSTOMER mailing list -SYSTEM
-- MONITOR mailing list is empty --- SICL mailing list -DSN%SICL
$ VAXSIM/FAULT
$ VAXSIM/FAULT
$ VAXSIM/FAULT
-- FSE mailing
ADD SYSTEM ALL
ADD FIELD ALL
SHOW MAIL
list --
FIELD
SYSTEM
-- CUSTOMER mailing list -FIELD
SYSTEM
-- MONITOR mailing list -FIELD
SYSTEM
-- SICL mailing list -DSN%SICL
FIELD
SYSTEM
To activate SICL after installation, use the following command:
System Troubleshooting and Diagnostics
5–37
$ VAXSIM/FAULT SET SICL ON
VAXsimPLUS customer notification messages should display a phone
number for the customer to call in the event the system needs service. Use
the following commands to examine and set the phone number parameter:
$ VAXSIM/FAULT SHOW PARAMETER
(SET parameter)
PHONE_NUMBER
COPY
SICL
SYSTEM_INFO
(Parameter settings)
Customer Service Phone Number is unknown
Automatic copying is OFF
System Initiated Call Logging is ON
System info for AB1X
Serial number
WFPROTO152
System type
VAX 4000-500
$ VAXSIM/FAULT SET PHONE 1-800-DIGITAL
Finally, the VAXSIMPLUS/MERGE command is useful in examining how a
device is functioning in a cluster. The merge command collects the messages
that are being sent to the other CPUs in the cluster.
5.2.10 Repair Data for Returning FRUs
When sending back an FRU for repair, include as much of the error log
information as possible. If one or more error flags are set in a particular
entry, record the mnemonic(s) of the register(s), the hex data, and error
flag translation(s) on the repair tag. If an error address is valid, include
the mnemonic, hex data, and translation on the repair tag as well. For
memory and cache errors, include the syndrome and corrected-bit/bitin-error information, along with the register mnemonic and hex data.
Other registers which should be recorded for any entry type are SYSTAT,
MEMCON and FOOTPRINT.
5.3 Interpreting Power-On Self Test (POST) and
ROM-Based Diagnostic (RBD) Failures
If any of the tests fail, the test code displays on the console LED and, if
specified in the firmware script, a diagnostic console printout displays in
the format shown in Example 5–11.
Example 5–11: Sample Output with Errors
Example 5–11 (continued on next page)
5–38 KA675/KA680/KA690 CPU System Maintenance
Example 5–11 (Cont.): Sample Output with Errors
?40 2 06 FF 0000 0010 00
; SUBTEST_40_06, DE_Memory_count_pages.LIS
P1=00000001 P2=00000004 P3=FFFFFFFF P4=00000000 P5=00000004
P6=00010000 P7=00000004 P8=00000000 P9=00000000 P10=00000000
r0=01FF4000 r1=00000004 r2=00000003 r3=FFFFFFFF r4=00000070
r5=00000000 r6=00000000 r7=00000000 r8=00000000 EPC=00000000
SCBB=20053C00
TODR=9FEBF5E9
ECR=0000008A
SCR=0000D000
DSER=00000000
QBEAR=0000000F
DEAR=00000000
QBMBR=01FF8000
BDR=B9F808AF
SSCCR=00D55570
IPCR0=0000
CESR=00000000
CMCDSR=0000C308 CSEAR1=00000000
CSEAR2=00000000
CIOEAR1=00000000 CIOEAR2=10000000 CNEAR=00000000
MAPEN=00000000
PCSTS=FFFFF800
PCADR=FFFFFFF8
PCCTL=FFFFFE00
ICSR=00000001
VMAR=000007E0
VTAG=0004008D
VDATA=AC31024E
CCTL=00000007 BCETSTS=00000000 BCETIDX=00000000
BCETAG=00000000
BCEDSTS=00000700 BCEDIDX=00000008 CEFSTS=00000200 BCEDECC=00000000
CEFADR=00000008
NESTS=00000000 NEOADR=E005C9E8
NEOCMD=8000FF04
NEICMD=00000000 NEDATHI=00000000 NEDATLO=00000000
MOAMR=00000000
MMCDSR=01111000
MEAR=08406010_____ADD=21018040
MESR=00080000
MEMCON_0:7; 0=80000003, 1=81000003
2=00000007, 3=00000007, 4=00000007, 5=00000007, 6=00000007, 7=00000007
Normal operation not possible.
>>>
Several lines are printed in the error display. The first line has eight column
headings:
Test identifies the diagnostic test, test ?40 in Example 5–11. Using
Table 5–9, you can use the test number to point to possible problems in
field replaceable units (FRUs).
Severity is the severity level of a test failure, as dictated by the script.
Failure of a severity level 2 test causes the display of this error printout
and halts an autoboot. An error of severity level 1 causes a display of
the first line of the error printout but does not interrupt an autoboot.
Most tests have a severity level of 2.
Error is two hex digits identifying, usually within 10 instructions,
where in the diagnostic the error occurred. This field is also called
the subtestlog.
De_error (diagnostic executive error) signals the diagnostic’s state and
any illegal behavior. This field indicates a condition that the diagnostic
expects on detecting a failure. FE or EF in this field means that an
unexpected exception or interrupt was detected. FF indicates an error
as a result of normal testing, such as a miscompare. The possible codes
are:
System Troubleshooting and Diagnostics
5–39
Error Code
Description
FF
Normal error exit from diagnostic
FE
Unanticipated interrupt
FD
Interrupt in cleanup routine
FC
Interrupt in interrupt handler
FB
Script requirements not met
FA
No such diagnostic
EF
Unanticipated exception in executive
Vector identifies the SCB vector through which the unexpected exception
or interrupt trapped, when the de_error field detects an unexpected
exception or interrupt (FE or EF).
Count is four hex digits. It shows the number of previous errors that
have occurred (16 in Example 5–11).
Loop_subtest_log is an additional log generated out of the current test
specified by the current test number and subtestlog. Usually these logs
occur in common subroutines called from a diagnostic test.
ASCII messages contain unique symbols that are terminated by the
comma in the ASCII field. These symbols identify the most recent
subtestlog entry in the listing file. The characters to the right of
the comma give the name of the listing file that contains the failed
diagnostic.
Lines 2 and 3 of the error printout are parameters 1 through 10. When
the diagnostics are running normally, these parameters are the same
parameters listed in Example 4–4.
When an unexpected machine check exception or other type of exception
occurs during the executive (de_error is EF), the stack is saved in the
parameters on lines 2 and 3, as listed in Table 5–6, Table 5–7, and
Table 5–8.
Table 5–6: Machine Check Exception During Executive
Parameter
Value
P1
P2
Contents of stack pointer, points to vector in P2
Vector = 004, machine check
5–40 KA675/KA680/KA690 CPU System Maintenance
Table 5–6 (Cont.): Machine Check Exception During Executive
Parameter
Value
P3
P4
P5
P6
P7
P8
P9
P10
Machine check code
Contents of VA register
Contents of VIBA register
ICCS register bit <6> and SISR <15:0>
Internal state information
Contents of shift count (SC) register
PC
PSL
Table 5–7: Exception During Executive with No Parameters
Parameter
Value
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
Contents of stack pointer, points to vector in P2
Vector = nnn (000-3FC), 200-3FC = Q–bus
PC
PSL
Contents of stack
Contents of stack
Contents of stack
Contents of stack
Contents of stack
Contents of stack
Table 5–8: Other Exceptions with Parameters, No Machine Check
Parameter
Value
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
Contents of stack pointer, points to vector in P2
Vector = nnn (20, 24, 34, 40, 44, 48, 4C, C8)
Optional parameters, could be more than one LW (20, 24, C8)
PC
PSL
Contents of stack
Contents of stack
Contents of stack
Contents of stack
Contents of stack
Lines 4 and 5 of the error printout are General Purpose Registers (GPRs)
R0 through R8 and the error program counter.
System Troubleshooting and Diagnostics
5–41
In general, the machine check exceptions can provide a clue to the cause
of the problem. Machine check codes 01–05, 08–10, 13, 0A, 0B, 0C, and
0D are probably due to CPU fault. Machine check codes 11 and 12 could
be a memory problem or a CPU problem. In the case of exceptions with
or without parameters (Table 5–7 and Table 5–8) the vector can provide a
clue to the fault.
When returning a module for repair, record the first line of the error
printout and the version of the ROMs on the module repair tag.
Table 5–9 lists the hex LED display, the default action on errors, and the
most likely unit that needs replacing.
The Default on Error column refers to the action taken by the diagnostic
executive under the following circumstances:
•
The diagnostic executive detects an unexpected exception or interrupt.
•
A test fails and that failure is reported to the diagnostic executive.
The Default on Error column does not refer to the action taken by the
memory tests. The diagnostic executive either halts the script or continues
execution at the next test in the script.
Most memory tests have a continue on error parameter (labeled cont_
on_error). If you explicitly set cont_on_error, using parameter 4 in a
memory test, the test marks bad pages in the bitmap and continues without
notifying the diagnostic executive of the error. In this case, a halt on
error does not occur even if you specify halt on error in the diagnostic
executive (by answering Yes to Stop script on error? in Utility 9F), since
the memory test does not notify the diagnostic executive that an error has
occurred.
Table 5–9 shows the various LED values and console terminal displays as
they point to problems in field-replaceable units (FRUs).
5–42 KA675/KA680/KA690 CPU System Maintenance
Table 5–9: KA675/KA680/KA690 Console Displays As Pointers to
FRUs
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
FRU1
Power-Up Tests (Script A1)
F
E
D
C
B
9
8
8
B
B
B
B
8
8
B
9
9
9
9
B
6
7
7
C
C
C
C
None
None
None
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
Loop
Loop
Loop
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Halt
Cont
Halt
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
None
None
None
?9D
?42
?35
?33
?32
?D0
?D2
?DF
?DC
?31
?30
?46
?35
?DE
?DD
?DA
?54
?60
?91
?90
?C6
?52
?52
?53
Power up
Wait for power
–
Utility
Check for interrupts
B_Cache diag_mode
NMC_powerup
NMC_registers
V_Cache_diag_mode
O_bit_Diag_mode
O-bit_debug
No_memory_present
Memory_setup_CSRs
Memory_Init_Bitmap
P_cache_diag_mode
B_cache_diag_mode
B_Cache_tag_debug
B_Cache_data_debug
PB_Flush_cache
Virtual_Mode
SSC_Console_SLU
CQBIC_powerup
CQBIC_registers
SSC_powerup
SSC_Prog_timers
SSC_Prog_timers
SSC_TOY_Clock
5,
5,
–
1
1,
1
1
1,
1
1
1
1,
1,
2,
1
1
1
1
1
1
1,
1,
1,
1,
1
1
7,
1
1
4
2
2, 3
2, 3
1
6
4, 3
4, 3
6
1
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
System Troubleshooting and Diagnostics
5–43
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
Displays
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
As
FRU1
Power-Up Tests (Script A1)
C
C
C
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
8
9
C
7
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
?C1
?34
?C5
?55
?49
?4F
?4E
?4B
?4A
?4C
?3F
?3F
?48
?48
?48
?48
?48
?48
?48
?48
?48
?4D
?47
?40
?40
?37
?C2
?80
SSC_RAM_Data
SSC_ROM
SSC_registers
Interval_Timer
Memory_FDM
Memory_Data
Memory_Byte
Memory_Byte_Errors
Memory_ECC_SBEs
Memory_ECC_Logic
Mem_FDM_address_shorts
Mem_FDM_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_address_shorts
Memory_Adress
Memory_Refresh
Memory_count_pages
Memory_count_pages
Cache_W_memory
SSC_RAM_Data_Addr
CQBIC_memory
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
5–44 KA675/KA680/KA690 CPU System Maintenance
1
1
1
1
1
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
1,
1
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
Displays
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
As
FRU1
Power-Up Tests (Script A1)
9
A
4
5
5
8
7
7
7
7
B
C
14
13
12
11
10
9
8
7
6
5
4
3
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
Cont
?37
?51
?5F
?5C
?5C
?9A
?83
?84
?85
?86
?DB
?41
Cache_w_memory
FPA
SGEC
SHAC (Bus 1)
SHAC (Bus 0)
INTERACTION
QZA_loopback1
QZA_loopback2
QZA_memory
QZA_DMA
Speed
Board_Reset
1,
1
1,
1,
1,
1,
4
4
4
4
1
1,
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?9D
?42
?35
?33
?32
?D0
?D2
?DF
?DC
?31
?30
?46
Utility
Chk_for_Interrupts
B_Cache_diag_mode
NMC_powerup
NMC_registers
V_Cache_diag_mode
O-bit_Diag_mode
O_bit_debug
No_memory_presnt
Memory_setup_CSRs
Memory_Init_Bitmap
P_cache_diag_mode
1
1,
1
1
1,
1
1
1
1,
1,
2,
1
2
6
3
6
6
4
Script A3
C
B
9
8
8
B
B
B
8
8
8
B
9D
42
35
33
32
D0
D2
DF
DC
31
30
46
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
4
2
2, 3
2, 3
1
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
System Troubleshooting and Diagnostics
5–45
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
Displays
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
As
FRU1
Script A3
9
9
9
9
B
6
7
7
C
C
C
C
C
C
C
B
8
8
8
8
8
8
8
8
8
8
8
8
35
DE
DD
DA
54
60
91
90
C6
52
52
53
C1
34
C5
55
49
4F
4E
4B
4A
4C
3F
3F
48
48
48
48
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?35
?DE
?DD
?DA
?54
?60
?91
?90
?C6
?52
?52
?53
?C1
?34
?C5
?55
?49
?4F
?4E
?4B
?4A
?4C
?3F
?3F
?48
?48
?48
?48
B_cache_diag_mode
B_Cache_tag_debug
B_Chace_data_debug
PB_Flush_cache
Virtual_Mode
SSC_Console_SLU
CQBIC_powerup
CQBIC_registers
SSC_powerup
SSC_Prog_timers
SSC_Prog_timers
SSC_TOY_Clock
SSC_RAM_Data
SSC_ROM
SSC_registers
Interval_Timer
Memory_FDM
Memory_Data
Memory_Byte
Memory_Byte_Errors
Memory_ECC_SBEs
Memory_ECC_Logic
Memory_FDM_Addr_shorts
Memory_FDM_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
5–46 KA675/KA680/KA690 CPU System Maintenance
1
1
1
1
1
1,
1,
1,
1,
1
1
7,
1
1
1
1
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
6
4, 3
4, 3
6
1
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
3
3
3
3
3
3
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
Displays
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
As
FRU1
Script A3
8
8
8
8
8
8
8
8
8
9
C
7
9
A
4
5
5
8
7
7
7
7
B
C
48
48
48
48
48
4D
47
40
40
37
C2
80
37
51
5F
5C
5C
9A
83
84
85
86
DB
41
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?48
?48
?48
?48
?48
?4D
?47
?40
?40
?37
?C2
?80
?37
?51
?5F
?5C
?5C
?9A
?83
?84
?85
?86
?DB
?41
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Address
Memory_Refresh
Memory_count_pages
Memory_count_pages
Cache_W_memory
SSC_RAM_Data_Addr
CQBIC_memory
Cache_w_memory
FPA
SGEC
SHAC
SHAC
INTERACTION
QZA_LPBCK1
QZA_LPBCK2
QZA_memory
QZA_DMA
Speed
Board_Reset
2, 1, 3
2, 1, 3
2, 1, 3
2, 1, 3
2, 1, 3
2, 1, 3
2, 1, 3
2, 1, 3
2, 1, 3
1, 2
1
1, 2
1, 2
1
1, 6
1, 3
1, 6
1,2,3,4
4
4
4
4
1
1, 4
Script A4
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
System Troubleshooting and Diagnostics
5–47
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
Displays
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
As
FRU1
Script A4
Invoke script A3 (Loop on A3)
Script A5
8
8
8
8
8
8
8
8
8
8
3F
3F
48
48
48
48
48
48
48
48
Cont
Cont
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?3F
?3F
?48
?48
?48
?48
?48
?48
?48
?48
Mem_FDM_Addr_Shorts
Mem_FDM_Addr_Shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
3
3
3
3
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?30
?4F
?4E
?4D
?4C
?4B
?4A
?3F
?48
?48
Memory_Init_Bitmap
Memory_Data
Memory_Byte
Memory_Address
Memory_ECC_Logic
Memory_Byte_Errors
Memory_ECC_SBEs
Mem_FDM_Addr_Shorts
Mem_Addr_Shorts
Mem_Addr_Shorts
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
3
3
3
3
Script A6
8
8
8
8
8
8
8
8
8
8
30
4F
4E
4D
4C
4B
4A
3F
48
48
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
5–48 KA675/KA680/KA690 CPU System Maintenance
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
Displays
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
As
FRU1
Script A6
8
8
8
8
8
8
8
8
7
48
48
48
48
48
48
47
40
80
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?48
?48
?48
?48
?48
?48
?47
?40
?80
Mem_Addr_Shorts
Mem_Addr_Shorts
Mem_Addr_Shorts
Mem_Addr_Shorts
Mem_Addr_Shorts
Mem_Addr_Shorts
Memory_Refresh
Memory_count_pages
CQBIC_memory
2,
2,
2,
2,
2,
2,
2,
2,
2,
1,
1,
1,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
3
3
3
Halt
Halt
Halt
?31
?30
?49
Memory_Setup_CSRs
Memory_Init_Bitmap
Memory_FDM
2, 1, 3
2, 1, 3
2, 1, 3
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
?4F
?4E
?4D
?4C
?4B
?4A
?3F
?48
Memory_Data
Memory_Byte
Memory_Address
Memory_ECC_Logic
Memory_Byte_Errors
Memory_ECC_SBEs
Mem_FDM_Addr_shorts
Memory_Addr_shorts
2,
2,
2,
2,
2,
2,
2,
2,
Script A8
8
31
8
30
8
49
Invoke script A7.
Script A7
8
8
8
8
8
8
8
8
4F
4E
4D
4C
4B
4A
3F
48
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
1,
1,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
3
3
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
System Troubleshooting and Diagnostics
5–49
Table 5–9 (Cont.): KA675/KA680/KA690
Pointers to FRUs
Console
On Er- Normal Default Ac- On Error
ror Hex Console tion on Er- Console DisLED
Display ror
play
Test Description
Displays
As
FRU1
Script A7
8
8
8
8
8
8
8
8
8
7
C
48
48
48
48
48
48
48
47
40
80
41
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Cont
Cont
Halt
?48
?48
?48
?48
?48
?48
?48
?47
?40
?80
?41
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Addr_shorts
Memory_Refresh
Memory_count_pages
CQBIC_memory
Board_Reset
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
2,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
3
3
3
3
3
Halt
Halt
Halt
Halt
Halt
Halt
?4F
?4E
?4D
?4C
?4B
?4A
Memory_Data
Memory_Byte
Memory_Address
Memory_ECC_Logic
Memory_Byte_Errors
Memory_ECC_SBEs
2,
2,
2,
2,
2,
2,
1,
1,
1,
1,
1,
1,
3
3
3
3
3
3
Halt
Halt
Cont
Cont
?4D
?47
?40
?41
Memory_Address
Memory_Refresh
Memory_count_pages
Board_Reset
2,
2,
2,
2,
1,
1,
1,
1,
3
3
3
3
Script A9
8
4F
8
4E
8
4D
8
4C
8
4B
8
4A
Invoke script A5.
8
4D
8
47
8
40
C
41
End of script.
1 Field-replaceable
1
2
3
4
5
6
7
=
=
=
=
=
=
=
unit key:
KA675/KA680/KA690
MS690
Backplane
Q22–bus device
System power supply
H3604 console module
Battery
5–50 KA675/KA680/KA690 CPU System Maintenance
5.3.1 FE Utility
In addition to the diagnostic console display and the LED code, the FE
utility dumps diagnostic state to the console (Example 5–12). This state
indicates the major and minor test code of the test that failed, the 10
parameters associated with the test, and the hardware error summary
register.
Running the FE utility is useful if the message Normal operation not
possible is displayed after the tests have completed and there is no other
error indication, or if you need more information than what is provided in
the error display.
Example 5–12: FE Utility Example
>>>T FE
Bitmap=07FEC000, Length=00008000, Checksum=0000, Busmap=07FF8000
Test_number=00, Subtest=00, Loop_Subtest=00, Error_type=00
Error_vector=0000, Severity=02, Last_exception_PC=00000000
Total_error_count=0000, Led_display=09, Console_display=9E, save_mchk_code=00
parameter_1=00000000 2=00000000 3=00000000 4=00000000 5=00000000
parameter_6=00000000 7=0001E9FC 8=0001EEE5 9=0001EC72 10=00000000
previous_error=00000000, 00000000, 00000000, 00000000
Flags=FFFF C050 443E
BCache_Disable=06 KA680, 128KB BC, 14.0 ns
Return_stack=201406A8, Subtest_pc=2005B225, Timeout=00030D40
Interrupted test number = 48, Subtestlog=04, Loop_Subtestlog=00, Error_type=FF
>>>
The most useful fields displayed above are as follows:
•
Error_vector, which is the SCB vector through which the unexpected
interrupt or exception trapped if de_error equals FE or EF.
•
Total_error_count. Four hex digits showing the number of previous
errors that have occurred.
•
Parameters 1 through 10. Valid only if the test halts on error.
•
Previous_error. Contains the history of the last four errors. Each
longword contains four bytes of information. From left to right these
are the de_error, subtest_log, test, and subtest number (00=FF in the
de_error).
•
Save machine check code (save_mchk_code). Valid only if the test halts
on error. This field has the same format as the hardware error summary
register.
System Troubleshooting and Diagnostics
5–51
5.3.2 Overriding Halt Protection
The ROM-based diagnostics run in halt-protected space. When you want to
halt diagnostic execution, if the diagnostic program hangs during execution
or if the runtime of the diagnostic program is so long you want to suspend
it, enter the following commands:
>>>E 20140010
!Examine the SSCCR
P 20140010
00D55570
>>>D * 00D05570
!Clear halt-protected space
>>>T 0
!Tests can now be halted
This state is in effect only until the first break or a restart.
5.3.3 Isolating Memory Failures
This section describes procedures for isolating memory subsystem failures,
particularly when the system contains more than one MS690 memory
module.
1. SHOW MEMORY/FULL
Use the SHOW MEMORY/FULL command to examine failures detected
by the memory tests. Use this command if test 40 fails, which indicates
that pages have been marked bad in the bitmap.
You can also use SHOW MEMORY/FULL after terminating a script
that is taking an unusually long time to run. After terminating the
script, enter SHOW MEMORY/FULL to see if the tests have marked
any pages bad up to that point. The following is an example using this
command.
>>>SHOW MEMORY/FULL
Memory 0: 00000000 to 01FFFFFF, 32MB, 37 bad pages
Total of 32MB, 37 bad pages, 112 reserved pages
Memory Bitmap
-01FF2000 to 01FF3FFF, 16 pages
Console Scratch Area
-01FF4000 to 01FF7FFF, 32 pages
Qbus Map
-01FF8000 to 01FFFFFF, 64 pages
5–52 KA675/KA680/KA690 CPU System Maintenance
Scan of Bad Pages
-0000C000 to 0000CFFF,
-0000E000 to 0000EFFF,
-00724200 to 007247FF,
-00724A00 to 007251FF,
-00725400 to 00725BFF,
-00726400 to 00726DFF,
-00727400 to 00727DFF,
8
8
3
4
4
5
5
pages
pages
pages
pages
pages
pages
pages
>>>
2. T A9
>>>T [memory test] starting_board_number ending_board_number
adr_incr
Script A9 runs only the memory tests and halts on the first error
detected. Unlike the power-up script, it does not continue. Since the
script does not rerun the test, it detects memory-related failures that
are not hard errors. You should then run the individual test that failed
on each memory module one MS690 module at a time. You can input
parameters 1 and 2 of tests 40, 47, 48, and 4A through 4F as the
starting and ending address for testing. It is easier, however, to input
the memory module numbers 1–4. For example, if test 4F fails, test
the second memory module as follows:
>>>T 4F 2 2
You should run this test for each memory module; if a failure is detected
on MS690 number 2, for example, and there are four memory modules
in the system, continue testing the rest of the modules to isolate the
FRU using the process of elimination.
You can also specify the address increment. For example, to test the
third memory module on each page boundary, type:
>>>T 4F 3 3 200
By default, the memory tests increment by 1-Mbyte, testing one
longword in each 256-Kbyte block. If an error is detected, the tests start
testing on a page boundary. Test 48 (address shorts test) is an exception:
it checks every location in memory since it can do so in a reasonable
amount of time. Other tests, such as 4F (floating ones and zeros test),
can take up to one hour, depending on the amount of memory, if each
location were to be tested. If you do specify an address increment, do
not input less than 200 (testing on a page boundary), since almost all
hard memory failures span at least one page. For normal servicing,
do not specify the address increment, since it adds unnecessary repair
time; most memory subsystem failures can be found using the default
parameter.
System Troubleshooting and Diagnostics
5–53
All memory tests, except for 40, save the MMCDSR, MESR, MEAR in
parameters 7, 8, and 9, respectively.
3. T 9C
The utility 9C is useful if test 31 or some other memory test failed
because memory was not configured correctly. Refer to Section 4.4 to
see an example of the test 9C output.
To help in isolating an FRU, examine registers MEMCON 0–7 by
entering T 9C at the console I/O mode prompt.
4. T 40
Although the SHOW MEMORY/FULL command displays pages that
are marked bad by the memory test and is easier to interpret than
test 40, there is one instance in which test 40 reports information that
SHOW MEMORY/FULL does not report. You can use test 40 as an
alternative to running script A9 to detect soft memory errors. Specify
the third parameter in test 40 (see Table 5–9) to be the threshold for
soft errors. To allow zero errors, enter the following:
>>>T 40 1 4 0
This command tests the memory on four memory modules. Use it after
running memory tests individually or within a script. If test 40 fails
with subtestlog = 6, examine R5–R8 to determine how many errors have
been detected.
Additional Troubleshooting Suggestions
If more than one memory module is failing, the CPU module, or backplane,
as well as other MS690 modules may be the cause of failure.
Always check the seating of the module before replacing it. If the seating
appears to be improper, rerun the tests.
If you are rotating MS690 modules to verify that a particular memory
module is causing the failure, be aware that a module may fail in a different
way when in a different slot. Be sure that you map out both solid singlebit and multibit ECC failures as shown in step 2 of acceptance testing
(Section 4.4), since in one slot a board may fail most frequently with multibit
ECC failures, and in another slot with single-bit ECC failures.
Be sure to put the modules back in their original positions when you are
finished.
If memory errors are found in the operating system error log, use the CPU
ROM-based diagnostics to verify if it is an MS690 problem or if it is related
5–54 KA675/KA680/KA690 CPU System Maintenance
to the CPU or backplane. Follow steps 1–3 of Section 4.4 and step 4 above
to aid in isolating the failure.
5.4 Testing DSSI Storage Devices
A DSSI storage device (ISE) may fail either during initial power-up or
during normal operation. In both cases, the failure is indicated by the
lighting of the red Fault indicator on the drive’s front panel.
If the drive is unable to execute the Power-On Self Test (POST) successfully,
the red Fault indicator remains lit and the Run/Ready indicator does not
come on, or both indicators remain on.
POST is also used to handle two types of error conditions in the drive:
•
Controller errors are caused by the hardware associated with the
controller function of the drive module. A controller error is fatal to
the operation of the drive, since the controller cannot establish a logical
connection to the host. The red Fault indicator lights. If this occurs,
replace the drive module.
•
Drive errors are caused by the hardware associated with the drive
control function of the drive module. These errors are not fatal to the
drive, since the drive can establish a logical connection and report the
error to the host. Both indicators go out for about 1 second, then the
red Fault indicator lights. In this case, run either DRVTST, DRVEXR,
or PARAMS (described in drive’s service documentation) to determine
the error code.
Three configuration errors also commonly occur:
•
More than one node with the same bus node ID number
•
Identical node names
•
Identical MSCP unit numbers
The first error cannot be detected by software. Use the SHOW DSSI
command to display the second and third types of errors. This command
lists each device connected to the DSSI bus by node name and unit number.
If the ISE is connected to its front panel, you must install a bus node ID plug
in the corresponding socket on the front panel. If the ISE is not connected
to its front panel, it reads the bus node ID from the three-switch DIP switch
on the side of the drive. DSSI storage devices contain the following local
programs:
System Troubleshooting and Diagnostics
5–55
DIRECT
DRVTST
DRVEXR
HISTRY
ERASE
VERIFY
DKUTIL
PARAMS
A directory, in DUP specified format, of available local programs
A comprehensive drive functionality verification test
A utility that exercises the ISE
A utility that saves information retained by the drive, including the internal
error log
A utility that erases all user data from the disk
A utility that is used to determine the amount of ‘‘margin’’ remaining in ondisk structures.
A utility that displays disk structures and disk data.
A utility that allows you to look at or change drive status, history, parameters,
and the internal error log
Use the SET HOST/DUP command (described in Section 3.7.3.3) to access
the local programs listed above. Example 5–13 provides an abbreviated
example of running DRVTST for an ISE (Bus node 2 on Bus 0).
CAUTION: When running internal drive tests, always use the default (0
= No) in responding to the ‘‘Write/read anywere on medium?’’ prompt.
Answering yes could destroy data.
Example 5–13: Running DRVTST
>>>SET HOST/DUP/DSSI/BUS:0 2 DRVTST
Starting DUP server...
Copyright (C) 1992 Digital Equipment Corporation
Write/read anywhere on medium? [1=Yes/(0=No)] Return
5 minutes to complete.
GAMMA::MSCP$DUP 17-MAY-1991 12:51:20 DRVTST CPU=
GAMMA::MSCP$DUP 17-MAY-1991 12:51:40 DRVTST CPU=
GAMMA::MSCP$DUP 17-MAY-1991 12:52:00 DRVTST CPU=
.
.
.
GAMMA::MSCP$DUP 17-MAY-1991 12:55:42 DRVTST CPU=
Test passed.
0 00:00:09.29 PI=160
0 00:00:18.75 PI=332
0 00:00:28.40 PI=503
0 00:02:13.41 PI=2388
Stopping DUP server...
>>>
Example 5–14 provides an abbreviated example of running DRVEXR for an
ISE (Bus node 2 on Bus 0).
CAUTION: When running internal drive tests, always use the default (0
= No) in responding to the ‘‘Write/read anywere on medium?’’ prompt.
Answering yes could destroy data.
5–56 KA675/KA680/KA690 CPU System Maintenance
Example 5–14: Running DRVEXR
>>>SET HOST/DUP/DSSI/BUS:0 2 DRVEXR
Starting DUP server...
Copyright (C) 1992 Digital Equipment Corporation
Write/read anywhere on medium? [1=Yes/(0=No)] Return
Test time in minutes? [(10)-100] Return
Number of sectors to transfer at a time? [0 - 50] 5/bold
Compare after each transfer? [1=Yes/(0=No)]: Return
Test the DBN area? [2=DBN only/(1=DBN and LBN)/0=LBN only]: Return
10 minutes to complete.
GAMMA::MSCP$DUP 17-MAY-1991 13:02:40 DRVEXR CPU= 0 00:00:25.37
GAMMA::MSCP$DUP 17-MAY-1991 13:03:00 DRVEXR CPU= 0 00:00:29.53
GAMMA::MSCP$DUP 17-MAY-1991 13:03:20 DRVEXR CPU= 0 00:00:33.89
.
.
.
GAMMA::MSCP$DUP 17-MAY-1991 13:12:24 DRVEXR CPU= 0 00:02:24.19
13332 operations completed.
33240 LBN blocks (512 bytes) read.
0 LBN blocks (512 bytes) written.
33420 DBN blocks (512 bytes) read.
0 DBN blocks (512 bytes) written.
0 bytes in error (soft).
0 uncorrectable ECC errors.
Complete.
PI=1168
PI=2503
PI=3835
PI=40028
Stopping DUP server...
>>>
Refer to the RF-Series Integrated Storage Element Service Guide for
instructions on running these programs.
5.5 Using MOP Ethernet Functions to Isolate
Failures
The console requester can receive LOOPED_DATA messages from the
server by sending out a LOOP_DATA message using NCP to set this up.
An example follows.
Identify the Ethernet adapter address for the system under test and
attempt to boot over the network.
***system 1 (system under test)***
>>>SHOW ETHERNET
Ethernet Adapter
-EZA0 (08-00-2B-28-18-2C)
>>>BOOT EZA0
(BOOT/R5:2 EZA0)
2..
-EZA0
Retrying network bootstrap.
System Troubleshooting and Diagnostics
5–57
Unless the system is able to boot, the ‘‘Retrying network bootstrap’’ message
will display every 8–12 minutes.
Identify the system’s Ethernet circuit and circuit state, enter the SHOW
KNOWN CIRCUITS command.
$ MCR NCP
NCP>SHOW KNOWN CIRCUITS
Known Circuit Volatile Summary as of 14-NOV-1991 16:01:53
Circuit
ISA-0
State
Loopback
Name
on
Adjacent
Routing Node
25.1023 (LAR25)
NCP>SET CIRCUIT ISA-0 STATE OFF
NCP>SET CIRCUIT ISA-0 SERVICE ENABLED
NCP>SET CIRCUIT ISA-0 STATE ON
NCP>LOOP CIRCUIT ISA-0 PHYSICAL ADDRESS 08-00-2B-08-18-2C
WITH ZEROES
NCP>EXIT
$
If the loopback message was received successfully, the NCP prompt will
reappear with no messages.
The following two examples show how to perform the Loopback Assist
Function using another node on the network as an assistant and the system
under test as the destination. Both assistant and system under test are
attempting to boot from the network. We will also need the physical address
of the assistant node.
***system #3 (loopback assistant)***
>>>SHOW ETHERNET
Ethernet Adapter
-EZA0 (08-00-2B-1E-76-9E)
>>>b eza0
(BOOT/R5:2 EZA0)
2..
-EZA0
Retrying network bootstrap.
***system 2***
NCP>LOOP CIRCUIT ISA-0 PHYSICAL ADDRESS 08-00-2b-28-18-2C ASSISTANT PHYSICAL
ADDRESS 08-00-2B-1E-76-9E WITH MIXED COUNT 20 LENGTH 200 HELP FULL
NCP>
Instead of using the physical address, you could use the assistant node’s
area address. When using the area address, system 3 is running VMS.
***system 3***
$MCR NCP
NCP>SHOW NODE KLATCH
Node Volatile Summary as of 27-FEB-1992 21:04:11
5–58 KA675/KA680/KA690 CPU System Maintenance
Executor node = 25.900 (KLATCH)
State
Identification
Active links
= on
= DECnet-VAX V5.4-1,
= 2
VMS V5.4-2
NCP>SHOW KNOWN LINES CHARACTERISTICS
Known Line Volatile Characteristics as of 27-FEB-1992 11:20:50
Line = ISA-0
Receive buffers
Controller
Protocol
Service timer
Hardware address
Device buffer size
=
=
=
=
=
=
6
normal
Ethernet
4000
08-00-2B-1E-76-9E
1498
NCP>SET CIRCUIT ISA-0 STATE OFF
NCP>SET CIRCUIT ISA-0 SERVICE ENABLED
NCP>SET CIRCUIT ISA-0 STATE ON
NCP>EXIT
$
***system 2***
$ MCR NCP
NCP>LOOP CIRCUIT ISA-0 PHYSICAL ADDRESS 08-00-2B-28-18-2C ASSISTANT NODE 25.900
WITH MIXED COUNT 20 LENGTH 200 HELP FULL
NCP>EXIT
$
NOTE: The kernel’s Ethernet buffer is 1024 bytes deep for the LOOP
functions and will not support the maximum 1500-byte transfer length.
In order to verify that the address is reaching this node, a remote node can
examine the status of the periodic SYSTEM_IDs sent by the KA675/KA680
/KA690 Ethernet server. The SYSTEM_ID is sent every 8–12 minutes using
NCP as in the following example:
$ MCR NCP
NCP>SET MODULE CONFIGURATOR CIRCUIT ISA-0 SURVEILLANCE ENABLED
NCP>SHOW MODULE CONFIGURATOR KNOWN CIRCUITS STATUS
NCP>EXIT
$ TYPE ETHER.LIS
Circuit name
Surveillance flag
Elapsed time
Physical address
Time of last report
Maintenance version
Function list
Hardware address
Device type
=
=
=
=
=
=
=
=
=
ISA-0
enabled
00:09:37
08-00-2B-28-18-2C
27-Feb 11:50:34
V4.0.0
Loop, Multi-block loader, Boot, Data link counters
08-00-2B-28-18-2C
ISA
Depending on your network, the file used to receive the output from the
SHOW MODULE CONFIGURATOR command may contain many entries,
most of which do not apply to the system you are testing. It is helpful to
use an editor to search the file for the Ethernet hardware address of the
System Troubleshooting and Diagnostics
5–59
system under test. Existence of the hardware address verifies that you are
able to recieve the address from the system under test.
5.6 Interpreting User Environmental Test Package
(UETP) VMS Failures
When UETP encounters an error, it reacts like a user program. It either
returns an error message and continues, or it reports a fatal error and
terminates the image or phase. In either case, UETP assumes the hardware
is operating properly and it does not attempt to diagnose the error.
If the cause of an error is not readily apparent, use the following methods
to diagnose the error:
•
VMS Error Log Utility—Run the Error Log Utility to obtain a detailed
report of hardware and system errors. Error log reports provide
information about the state of the hardware device and I/O request
at the time of each error. For information about running the Error Log
Utility, refer to the VMS Error Log Utility Manual and Section 5.2 of
this manual.
•
Diagnostic facilities—Use the diagnostic facilities to test exhaustively
a device or medium to isolate the source of the error.
5.6.1 Interpreting UETP Output
You can monitor the progress of UETP tests at the terminal from which they
were started. This terminal always displays status information, such as
messages that announce the beginning and end of each phase and messages
that signal an error.
The tests send other types of output to various log files, depending on how
you started the tests. The log files contain output generated by the test
procedures. Even if UETP completes successfully, with no errors displayed
at the terminal, it is good practice to check these log files for errors.
Furthermore, when errors are displayed at the terminal, check the log files
for more information about their origin and nature.
5.6.1.1 UETP Log Files
UETP stores all information generated by all UETP tests and phases from
its current run in one or more UETP.LOG files, and it stores the information
from the previous run in one or more OLDUETP.LOG files. If a run
of UETP involves multiple passes, there will be one UETP.LOG or one
OLDUETP.LOG file for each pass.
At the beginning of a run, UETP deletes all OLDUETP.LOG files, and
renames any UETP.LOG files to OLDUETP.LOG. Then UETP creates a
5–60 KA675/KA680/KA690 CPU System Maintenance
new UETP.LOG file and stores the information from the current pass in the
new file. Subsequent passes of UETP create higher versions of UETP.LOG.
Thus, at the end of a run of UETP that involves multiple passes, there is
one UETP.LOG file for each pass. In producing the files UETP.LOG and
OLDUETP.LOG, UETP provides the output from the two most recent runs.
If the run involves multiple passes, UETP.LOG contains information from
all the passes. However, only information from the latest run is stored
in this file. Information from the previous run is stored in a file named
OLDUETP.LOG. Using these two files, UETP provides the output from its
tests and phases from the two most recent runs.
The cluster test creates a NETSERVER.LOG file in SYS$TEST for each
pass on each system included in the run. If the test is unable to
report errors (for example, if the connection to another node is lost), the
NETSERVER.LOG file on that node contains the result of the test run
on that node. UETP does not purge or delete NETSERVER.LOG files;
therefore, you must delete them occasionally to recover disk space.
If a UETP run does not complete normally, SYS$TEST might contain other
log files. Ordinarily these log files are concatenated and placed within
UETP.LOG. You can use any log files that appear on the system disk for
error checking, but you must delete these log files before you run any new
tests. You may delete these log files yourself or rerun the entire UETP,
which checks for old UETP.LOG files and deletes them.
5.6.1.2 Possible UETP Errors
This section is intended to help you identify problems you might encounter
running UETP.
The following are the most common failures encountered while running
UETP:
•
Wrong quotas, privileges, or account
•
UETINIT01 failure
•
Ethernet device allocated or in use by another application
•
Insufficient disk space
•
Incorrect VAXcluster setup
•
Problems during the load test
•
DECnet–VAX error
•
Lack of default access for the FAL object
•
Errors logged but not displayed
System Troubleshooting and Diagnostics
5–61
•
No PCB or swap slots
•
Hangs
•
Bug checks and machine checks
For more information refer to the VAX 3520, 3540 VMS Installation and
Operations (ZKS166) manual.
5.7 Using Loopback Tests to Isolate Failures
You can use external loopback tests to isolate problems with the console
port, DSSI adapters (SHAC chips), Ethernet controller (SGEC chip), and
many common Q–bus options.
If one or more of these tests fail, check that the DC power and pico fuses on
the H3604 are OK. There are four pico fuses located on the back of H3604
console module. One fuse (F3) is on the outside, the other three are on the
component side. If a fuse is bad, replace the fuse–not the H3604.
Table 5–10 lists symptoms associated with faulty fuses. Figure 5–10 shows
the location of the H3604 fuses.
5–62 KA675/KA680/KA690 CPU System Maintenance
Table 5–10: H3604 Console Module Fuses
Fuse
Part Number
Symptom
F1 (+12 V, 1/2 A)
12–09159-00
ThinWire Ethernet LED on H3604 is not lit.
Ethernet external loopback test 5F fails if the
Ethernet connector switch is set to ThinWire.
F2 (-12 V, 1/16 A)
90–09122–00
No console display
F3 (+5 V, 2 A)
12–10929–06
LEDs on both DSSI terminators (Bus 1) on the H3604
console module are not lit; the DSSI terminator for
Bus 0 is lit.
SHOW DSSI or SHOW DEVICE commands show
DSSI bus 0, but console displays message indicating
that DSSI bus 1 terminators are missing or not
functioning.
DSSI SHAC (Bus 1) test 5C fails (countdown number
11).
F4 (+12 V, 1.5 A)
12–10929-08
The LED on the loopback connector (12-22196-02) for
standard Ethernet is not lit.
External loopback test 5F for the standard Ethernet
passes, however.
System Troubleshooting and Diagnostics
5–63
Figure 5–10: H3604 Console Module Fuses
Battery Backup Unit
W2
W4
J6
J1
J1 = TOY Clock Battery
J5 = H3604 Power
J6 = CPU Interface
W2 = Remote Boot Enable
W4 = FEPROM Write Enable
F2
F4
F1
J5
F3
F1 = ThinWire Ethernet Power, 0.5 A
PN = 12-09159-00
F2 = -12V Power, 0.062 A
PN = 90-09122-00
F3 = DSSI Terminator Power, 2.0 A
PN = 12-10929-06
F4 = Standard Ethernet Power, 1.5 A
PN = 12-10929-08
MLO-006351
5.7.1 Testing the Console Port
To test the console port at power-up, set the Power-Up Mode switch on
the H3604 console module to the Loop Back Test Mode position (bottom)
and install an H3103 loopback connector into the MMJ of the H3604. The
H3103 connects the console port transmit and receive lines. At power-up,
the SLU_EXT_LOOPBACK test then runs a continuous loopback test.
While the test is running, the LED display on the H3604 console module
should alternate between 6 and 3. A value of 6 latched in the display
indicates a test failure. If the test fails, one of the following parts is faulty:
the KA675/KA680/KA690, the H3604, or the cabling.
To test out to the end of the console terminal cable:
1. Plug the MMJ end of the console terminal cable into the H3604.
2. Disconnect the other end of the cable from the terminal.
3. Place an H8572 adapter into the disconnected end of the cable.
4. Connect the H3103 to the H8572.
5–64 KA675/KA680/KA690 CPU System Maintenance
5. Cycle power and observe the LED.
5.7.2 Embedded DSSI Loopback Testing
NOTE: Loopback tests do not test for termination power. Use the following
procedure to check termination power:
Remove the external DSSI cable and terminate Busses 0 and 1. Check the
terminator LEDs to see if termination power is present.
•
No termination power at Bus 0 indicates a possible problem with the
internal cable (PN 17–02502–01) that connects DSSI Bus 0 from the
backplane.
•
No termination power at Bus 1 indicates a possible problem with the
Pico fuse (F3, PN 12–10929–06) on the H3604 console module or the
power harness module (PN 54–19789–01) for the console module. Refer
to Table 5–10 for symptoms of bad fuses.)
Power for DSSI Bus 0 is supplied by the Vterm regulator module, which
plugs into the BA440 backplane. There are no fuses on this module.
Test 56 tests both SHAC chips (the DSSI adapters). This test can be used
to check both SHAC chips, the internal DSSI (Bus 0) connectivity, external
DSSI cables, and the H3604 DSSI bus interconnect. Complete the following
procedures before running test 56.
1. Make sure the system is powered down, then connect DSSI Bus 0 to
DSSI Bus 1 with a standard external DSSI cable (BC21M–09). Place a
DSSI terminator on the remaining DSSI connector for Bus 1. It is not
critical which Bus 1 connector is used in connecting the cable.
NOTE: The DSSI bus must be terminated for the tests to execute
successfully.
2. Remove all DSSI bus node ID plugs from storage devices on Bus 0.
3. Install bus node ID plugs on the console module (H3604) so that Bus 0
and Bus 1 do not have the same bus node ID. For example, assign bus
node ID 6 to Bus 0 and bus node ID 7 to Bus 1.
4. Power up the system. Note that the red Fault indicator on the ISE front
panels will remain lit. This is normal when the bus node ID plugs have
been removed.
5. Run test 56. When tests have successfully completed, the console
prompt is displayed.
System Troubleshooting and Diagnostics
5–65
>>>T 56
>>>
This loopback test is useful for isolating DSSI problems. A list of FRUs in
order of probability follows:
1. The external BC21M–09 cable
2. The Vterm dual regulator module (PN 54–20404–01)
3. The internal cable that connects DSSI Bus 0 from the backplane to the
edge of the enclosure (PN 17–02502–01)
4. The internal cable that connects the CPU to the H3604 (PN 17–02353–
01)
5. The 2.0 A Pico fuse (F3) on the H3604 (PN 12–10929–06)
6. The KA675/KA680/KA690 module
Test 58 is a SHAC and ISE reset and can be used to verify that ISEs can be
accessed on the DSSI storage bus. Test 58 causes data packets to be passed
between the ISEs and the adapters, verifying that the ISEs are accessible.
Enter T 58 and specify DSSI bus (0 or 1) and the DSSI node ID of the ISE
to be tested.
>>>T 58 0 5
In the example above, Bus 0 node 5 was tested. (Each ISE has to be tested
separately.)
5.7.3 Embedded Ethernet Loopback Testing
NOTE: Before running Ethernet loopback tests, check that the problem is
not due to a missing terminator on a ThinWire T-connector. Also, refer to
Table 5–10 to check for symptoms of a bad fuse.
Test 5F is the internal loopback test for SGEC (Ethernet controller).
>>>T 5F
For an external SGEC loopback, enter "1".
>>>T 5F 1
Before running test 5F on the ThinWire Ethernet port, connect an H8223
T-connector with two H8225 terminators.
Before running test 5F on the standard Ethernet port, you must have a
12–22196–02 loopback connector installed.
5–66 KA675/KA680/KA690 CPU System Maintenance
NOTE: Make sure the Ethernet Connector Switch is set for the correct
Ethernet port.
T 59 polls other nodes on Ethernet to verify SGEC functionality. The
Ethernet cable must be connected to a functioning Ethernet. A series of
MOP messages are generated; look for response messages from other nodes.
>>>T 59
Reply
Total
Reply
Total
Reply
Total
.
.
.
Reply
Total
>>>
received from node: AA-00-04-00-FC-64
responses: 1
received from node: AA-00-04-00-47-16
responses: 2
received from node: 08-00-2B-15-48-70
responses: 3
received from node: AA-00-04-00-17-14
responses: 25
5.7.4 Q-Bus Option Loopback Testing
Module self-tests run when you power up the system. A module self-test
can detect hard or repeatable errors, but usually not intermittent errors.
A pass by a module self-test does not guarantee that the module is good,
because the test usually checks only the controller logic.
Table 5–11 lists loopback connectors for common devices. Refer to the
Microsystems Options manual for a description of specific module self-tests.
System Troubleshooting and Diagnostics
5–67
Table 5–11: Loopback Connectors for Common Devices
Device
Module Loopback
CXA16/CXB16
CXY08
DIV32
DPV11
DRQB3
DRV1W
DZQ11
Ethernet2
IBQ01
IEQ11
KA6nn/H3604
KFQSA
KMV1A
KZQSA
LPV11
H3103 + H85721
H3046 (50-pin)
H3072
12–15336–10 or H325
70-24767–01
12–15336–10 or H325
–
IBQ01–TA
17–01988–01
H3103
DSSI terminators
H3255
12–30552–01
12-15336-11
Cable Loopback
H3197 (25-pin)
H329 (12–27351–01)
17–01481–01 (from port 1 to port2)
H329 (12–27351–01)
–
H3103 + H8572
H3251
1 Use the appropriate cable to connect transmit-to-receive lines. H3101 and H3103 are doubleended cable connectors.
2 For ThinWire, use H8223–00 plus two H8225–00 terminators. For standard Ethernet, use
12–22196–02.
5–68 KA675/KA680/KA690 CPU System Maintenance
Chapter 6
FEPROM Firmware Update
KA675/KA680/KA690 firmware is located on four chips, each 128 K by 8 bits
of FLASH programmable EPROMs, for a total of 512 Kbytes of ROM. (A
FLASH EPROM is a programmable read-only memory that uses electrical
(bulk) erasure rather than ultraviolet erasure.)
FEPROMs provide nonvolatile storage of the CPU power-up diagnostics,
console interface, and operating system primary bootstrap (VMB). An
advantage of this technology is that the entire image in the FEPROMs
may be erased, reprogrammed, and verified in place without removing the
CPU module or replacing components.
A slight disadvantage to the FEPROM technology is that the entire part
must be erased before reprogramming. Hence, there is a small "window
of vulnerability" when the CPU has inoperable firmware. Normally, this
window is less than 30 seconds. Nonetheless, an update should be allowed
to execute undisturbed.
Firmware updates are provided through a package called the Firmware
Update Utility. A Firmware Update Utility contains a bootable image,
which can be booted from tape or Ethernet, that performs the FEPROM
update. Firmware update packages, like software, are distributed through
Digital’s SSB. Service engineers are notified of updates through a service
blitz or Engineering Change Order (ECO)/Field Change Order (FCO)
notification.
NOTE: The NVAX CPU chip has an area called the Patchable Control Store
(PCS), which can be used to update the microcode for the CPU chip.
Updates to the PCS require a new version of the firmware.
A Firmware Update Utility image, consists of two parts, the update
program and the new firmware, as shown in Figure 6–1. The update
program uniformly programs, erases, reprograms, and verifies the entire
FEPROM.
FEPROM Firmware Update
6–1
Figure 6–1: Firmware Update Utility Layout
Update Program
New Firmware Image
MLO-007271
Once the update has completed successfully, normal operation of the system
may continue. The operator may then either halt or reset the system and
reboot the operating system.
6.1 Preparing the Processor for an FEPROM Update
Complete the following steps to prepare the processor for an FEPROM
update:
1. The system manager should perform operating system shutdown.
2. Enter console mode by pressing the Halt button twice—in to halt the
system, and out to enter console mode (>>>). If the Break Enable
/Disable switch on the console module is set to enable (indicated by
1), you can halt the system by pressing the Break key on the console
terminal.
3. In order to update the firmware, jumper W4 on the inside of the
H3604 console module must be in the "write enable mode," as shown in
Figure 6–2. (Write enable is the factory setting.)
To access the jumper you must open the H3604 console module by
unlocking the two half-turn screws that hold it closed.
6–2 KA675/KA680/KA690 CPU System Maintenance
Figure 6–2: W4 Jumper Setting for Updating Firmware
W4
J6
J1
F2
F4
F1
J5
F3
MLO-007697
6.2 Updating Firmware Via Ethernet
To update firmware via the Ethernet, the ‘‘client’’ system (the target
system to be updated) and the ‘‘server’’ system (the system that serves
boot requests) must be on the same Ethernet segment. The Maintenance
Operation Protocol (MOP) is the transport used to copy the network image.
Use the following procedure to update firmware via the Ethernet:
1. Be sure H3604 jumper W4 is in the correct ("write enable mode")
position (Section 6.1).
2. Enable the server system’s NCP circuit using the following VMS
commands:
$ MCR NCP
NCP>SET CIRCUIT <Circuit> STATE OFF
FEPROM Firmware Update
6–3
NCP>SET CIRCUIT <Circuit> SERVICE ENABLED
NCP>SET CIRCUIT <Circuit> STATE ON
Where <circuit> is the system Ethernet circuit. Use the SHOW
KNOWN CIRCUITS command to find the name of the circuit.
NOTE: The SET CIRCUIT STATE OFF command will bring down
the system’s network.
3. Copy the file containing the updated code to the MOM$LOAD area on
the server (this procedure may require system privileges). Refer to
the Firmware Update Utility Release Notes for the Ethernet bootable
filename. Use the following command to copy the file:
$ COPY <filename>.SYS MOM$LOAD:*.*
Where <filename> is the Ethernet bootable filename provided in the
release notes.
4. On the client system, enter the command BOOT/100 EZ at the console
prompt (>>>).
The system then prompts you for the name of the file.
NOTE: Do NOT type the ‘‘.SYS’’ suffix when entering the Ethernet
bootfile name. The MOP load protocol only supports 15 character
filenames.
5. After the FEPROM upgrade program is loaded, simply type "Y" at the
prompt to start the FEPROM blast. Example 6–1 provides a console
display of the FEPROM update program.
CAUTION: Once you enter the bootfile name, do not interrupt the
FEPROM blasting program, as this can damage the CPU module. The
program takes several minutes to complete.
NOTE: On systems with a VCB02 terminal, you will see an abbreviated
form of the following example.
6–4 KA675/KA680/KA690 CPU System Maintenance
Example 6–1: FEPROM Update Via Ethernet
***** On Server System *****
$ MCR NCP
NCP>SET CIRCUIT ISA-0 STATE OFF
NCP>SET CIRCUIT ISA-0 SERVICE ENABLED
NCP>SET CIRCUIT ISA-0 STATE ON
NCP>EXIT
$
$ COPY KA680_V41_EZ.SYS MOM$LOAD:*.*
$
***** On Client System *****
>>> BOOT/100 EZA0
(BOOT/R5:100 EZA0)
2..
Bootfile: K680_V41_EZ
-EZA0
1..0..
FEPROM BLASTING PROGRAM
blasting in V4.1...
---CAUTION--EXECUTING THIS PROGRAM WILL CHANGE YOUR CURRENT ROM --Do you really want to continue [Y/N] ? : Y
DO NOT ATTEMPT TO INTERRUPT PROGRAM EXECUTION!
DOING SO MAY RESULT IN LOSS OF OPERABLE STATE!
The program will take at most several minutes.
starting uniform_program...
byte 00070000 has
byte 00060000 has
byte 00050000 has
byte 00040000 has
byte 00030000 has
byte 00020000 has
byte 00010000 has
byte 00000000 has
starting erase...
been
been
been
been
been
been
been
been
byte 00070000 has been
byte 00060000 has been
byte 00050000 has been
byte 00040000 has been
byte 00030000 has been
byte 00020000 has been
byte 00010000 has been
byte 00000000 has been
starting program...
written
written
written
written
written
written
written
written
with
with
with
with
with
with
with
with
0’s...
0’s...
0’s...
0’s...
0’s...
0’s...
0’s...
0’s...
erased...
erased...
erased...
erased...
erased...
erased...
erased...
erased...
Example 6–1 (continued on next page)
FEPROM Firmware Update
6–5
Example 6–1 (Cont.): FEPROM Update Via Ethernet
byte
byte
byte
byte
byte
byte
byte
byte
00070000
00060000
00050000
00040000
00030000
00020000
00010000
00000000
has
has
has
has
has
has
has
has
been
been
been
been
been
been
been
been
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
FEPROM Programming successful
>>>
6. Press the Restart button on the SCP or enter "T 0" at the console prompt
(>>>).
7. If the customer requires, return jumper W4 on the inside of the H3604
console module to the "write disable mode" setting and close and secure
the console module by locking the half-turn screws.
6.3 Updating Firmware Via Tape
To update firmware via tape, the system must have a TF85, TK70, or TK50
tape drive.
If you need to make a bootable tape, copy the bootable image file to a tape
as shown in following example. Refer to the release notes for the name of
the file.
$
$
$
$
$
INIT MIA5:"VOLUME_NAME"
MOUNT/BLOCK_SIZE = 512 MIA5:"VOLUME_NAME"
COPY/CONTIG <file_name> MIA5:<file_name>
DISMOUNT MIA5
Use the following procedure to update firmware via tape:
1. Be sure H3604 jumper W4 is in the correct ("write enable mode")
position (Section 6.1).
2. At the console prompt (>>>), enter the BOOT/100 command for the tape
device, for example: BOOT/100 MIA5.
Use the SHOW DEVICE command if you are not sure of the device
name for the tape drive.
The system prompts you for the name of the file. Enter the bootfile
name.
6–6 KA675/KA680/KA690 CPU System Maintenance
3. After the FEPROM upgrade program is loaded, simply type "Y" at the
prompt to start the FEPROM blast. Example 6–2 provides a console
display of the FEPROM update program.
CAUTION: Once you enter the bootfile name, do not interrupt the
FEPROM blasting program, as this can damage the CPU module. The
program takes several minutes to complete.
NOTE: On systems with a VCB02 terminal, you will see an abbreviated
form of the following example.
FEPROM Firmware Update
6–7
Example 6–2: FEPROM Update Via Tape
>>> BOOT/100 MIA5
(BOOT/R5:100 MIA5)
2..
Bootfile: K680_V41_EZ
-MIA5
1..0..
FEPROM BLASTING PROGRAM
blasting in V4.1...
---CAUTION--EXECUTING THIS PROGRAM WILL CHANGE YOUR CURRENT ROM --Do you really want to continue [Y/N] ? : Y
DO NOT ATTEMPT TO INTERRUPT PROGRAM EXECUTION!
DOING SO MAY RESULT IN LOSS OF OPERABLE STATE!
The program will take at most several minutes.
starting uniform_program...
byte 00070000 has
byte 00060000 has
byte 00050000 has
byte 00040000 has
byte 00030000 has
byte 00020000 has
byte 00010000 has
byte 00000000 has
starting erase...
been
been
been
been
been
been
been
been
byte 00070000 has been
byte 00060000 has been
byte 00050000 has been
byte 00040000 has been
byte 00030000 has been
byte 00020000 has been
byte 00010000 has been
byte 00000000 has been
starting program...
byte
byte
byte
byte
byte
byte
byte
byte
00070000
00060000
00050000
00040000
00030000
00020000
00010000
00000000
has
has
has
has
has
has
has
has
been
been
been
been
been
been
been
been
written
written
written
written
written
written
written
written
with
with
with
with
with
with
with
with
0’s...
0’s...
0’s...
0’s...
0’s...
0’s...
0’s...
0’s...
erased...
erased...
erased...
erased...
erased...
erased...
erased...
erased...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
reprogrammed...
FEPROM Programming successful
>>>
4. Press the Restart button on the SCP or enter "T 0" at the console prompt
(>>>).
6–8 KA675/KA680/KA690 CPU System Maintenance
5. If the customer requires, return jumper W4 on the inside of the H3604
console module to the "write disable mode" setting and close and secure
the console module by locking the half-turn screws.
6.4 FEPROM Update Error Messages
The following is a list of error messages generated by the FEPROM update
program and actions to take if the errors occur.
MESSAGE:
update enable jumper is disconnected
unable to blast ROMs...
ACTION:
Reposition update enable jumper (Section 6.1).
MESSAGE:
ROM programming error-expected byte: xx actual byte: xx
at address: xxxxxxxx
ACTION:
Replace the CPU module.
MESSAGE:
ROM uniform pgming error-expected byte: 00 actual byte: xx
at address: xxxxxxxx
ACTION:
Turn off the system, then turn it on. If you see the banner message
as expected, re-enter console mode and try booting the update program
again. If you do not see the usual banner message, replace the CPU
module.
MESSAGE:
ROM erase error-expected byte: ff actual byte: xx
at address: xxxxxxxx
ACTION:
Replace the CPU module.
Patchable Control Store (PCS) Loading Error Messages
The following is a list of error messages that may appear if there is a
problem with the PCS. The PCS is loaded as part of the power-up stream
(before ROM-based diagnostics are executed).
MESSAGE:
FEPROM Firmware Update
6–9
CPU is not an NVAX
COMMENT:
CPU_TYPE as read in NVAX SID is not = 19 (decimal), as is should be
for an NVAX processor.
MESSAGE:
Microcode patch/CPU rev mismatch
COMMENT:
Header in microcode patch does not match MICROCODE_REV as read
in NVAX SID.
MESSAGE:
PCS Diagnostic failed
COMMENT:
Something is wrong with the PCS. Replace the NVAX chip (or CPU
module).
MESSAGE:
Unexpected SIE
COMMENT:
SYS_TYPE as read in the ROM SIE does not reflect that an NVAX CPU
is present.
6–10 KA675/KA680/KA690 CPU System Maintenance
Appendix A
KA675/KA680/KA690 Firmware
Commands
This appendix provides information on console mode control characters and
firware commands for the CPU module.
A.1 Console I/O Mode Control Characters
In console I/O mode, several characters have special meaning:
Also <CR>. The carriage return ends a command line. No action is taken
on a command until after it is terminated by a carriage return. A null
line terminated by a carriage return is treated as a valid, null command.
No action is taken, and the console prompts for input. Carriage return is
echoed as carriage return, line feed (<CR><LF>).
When you press RUBOUT , the console deletes the previously typed
character. The resulting display differs, depending on whether the console
is a video or a hardcopy terminal.
RETURN
RUBOUT
For hardcopy terminals, the console echoes a backslash (\ ), followed
by the deletion of the character. If you press additional rubouts, the
additional deleted characters are echoed. If you type a nonrubout
character, the console echoes another backslash, followed by the character
typed. The result is to echo the characters deleted, surrounding them with
backslashes. For example:
EXAMI;E
RUBOUT RUBOUT
NE<CR>
The console echoes: EXAMI;E\ E;\ NE<CR>
The console sees the command line: EXAMINE<CR>
For video terminals, the previous character is erased and the cursor is
restored to its previous position.
CTRL/A
and F14
The console does not delete characters past the beginning of a command
line. If you press more rubouts than there are characters on the line, the
extra rubouts are ignored. A rubout entered on a blank line is ignored.
Toggle insertion/overstrike mode for command line editing. By default, the
console powers up to overstrike mode.
KA675/KA680/KA690 Firmware Commands
A–1
CTRL/B or up_
arrow (or down_
arrow)
CTRL/D and left
arrow
CTRL/E
CTRL/F
arrow
and right
CTRL/H ,
backspace, and
F12
CTRL/U
CTRL/S
CTRL/Q
CTRL/R
CTRL/C
CTRL/O
Recalls previous command(s). Command recall is only operable if sufficient
memory is available. This function may then be enabled and disabled using
the SET RECALL command.
Move cursor left one position.
Moves cursor to the end of the line.
Move cursor right one position.
Move cursor to the beginning of the line.
Echoes ^U<CR> and deletes the entire line. Entered but otherwise ignored
if typed on an empty line.
Stops output to the console terminal until CTRL/Q is typed. Not echoed.
Resumes output to the console terminal. Not echoed.
Echoes <CR><LF>, followed by the current command line. Can be used to
improve the readability of a command line that has been heavily edited.
Echoes ^C<CR> and aborts processing of a command. When entered as
part of a command line, deletes the line.
Ignores transmissions to the console terminal until the next CTRL/O is
entered. Echoes ^O when disabling output, not echoed when it re-enables
output. Output is re-enabled if the console prints an error message, or if
it prompts for a command from the terminal. Output is also enabled by
entering console I/O mode, by pressing the BREAK key, and by pressing
CTRL/C .
A.1.1 Command Syntax
The console accepts commands up to 80 characters long. Longer commands
produce error messages. The character count does not include rubouts,
rubbed-out characters, or the RETURN at the end of the command.
You can abbreviate a command by entering only as many characters as are
required to make the command unique. Most commands can be recognized
from their first character. See Table A–5.
The console treats two or more consecutive spaces and tabs as a single
space. Leading and trailing spaces and tabs are ignored. You can place
command qualifiers after the command keyword or after any symbol or
number in the command.
All numbers (addresses, data, counts) are hexadecimal (hex), but symbolic
register names contain decimal register numbers. The hex digits are 0
through 9 and A through F. You can use uppercase and lowercase letters in
hex numbers (A through F) and commands.
The following symbols are qualifier and argument conventions:
A–2 KA675/KA680/KA690 CPU
[]
An optional qualifier or argument
{}
A required qualifier or argument
A.1.2 Address Specifiers
Several commands take one or more addresses as arguments. An address
defines the address space and the offset into that space. The console
supports five address spaces:
Physical memory
Virtual memory
General purpose registers (GPRs)
Internal processor registers (IPRs)
The PSL
The address space that the console references is inherited from the previous
console reference, unless you explicitly specify another address space. The
initial address space is physical memory.
A.1.3 Symbolic Addresses
The console supports symbolic references to addresses. A symbolic reference
defines the address space and the offset into that space. Table A–1 lists
symbolic references supported by the console, grouped according to address
space. You do not have to use an address space qualifier when using a
symbolic address.
Table A–1: Console Symbolic Addresses
Symb
Addr
Symb
Addr
Symb
Addr
Symb
Addr
/G—General Purpose Registers
R0
00
R4
04
R8
08
R12 (AP)
0C
R1
01
R5
05
R9
09
R13 (FP)
0D
R2
02
R6
06
R10
0A
R14 (SP)
0E
R3
03
R7
07
R11
0B
R15 (PC)
0F
/M—Processor Status Longword
PSL
—-
Note: All symbolic values in this table are in hexadecimal.
KA675/KA680/KA690 Firmware Commands
A–3
Table A–1 (Cont.): Console Symbolic Addresses
Symb
Addr
Symb
Addr
Symb
Addr
Symb
Addr
/I—Internal Processor Registers
pr$_ksp
00
pr$_pcbb
10
pr$_rxcs
20
—-
30
pr$_esp
01
pr$_scbb
11
pr$_rxdb
21
—-
31
pr$_ssp
02
pr$_ipl
12
pr$_txcs
22
—-
32
pr$_usp
03
pr$_astlv
13
pr$_txdb
23
—-
33
pr$_isp
04
pr$_sirr
14
—-
24
—-
34
—-
05
pr$_sisr
15
—-
25
—-
35
—-
06
—-
16
pr$_mcesr
26
—-
36
—-
07
—-
17
—-
27
pr$_ioreset
37
pr$_p0br
08
pr$_iccs
18
—-
28
pr$_mapen
38
pr$_p0lr
09
pr$_nicr
19
—-
29
pr$_tbia
39
pr$_p1br
0A
pr$_icr
1A
pr$_savpc
2A
pr$_tbis
3A
pr$_p1lr
0B
pr$_todr
1B
pr$_savpsl
2B
—-
3B
pr$_sbr
0C
—-
1C
—-
2C
—-
3C
pr$_slr
0D
—-
1D
—-
2D
—-
3D
—-
0E
—-
1E
—-
2E
pr$_sid
3E
—-
0F
—-
1F
—-
2F
pr$_tbchk
3F
pr$_ecr
7D
pr$_cctl
A0
pr$_neoadr
B0
pr$_vmar
D0
—-
F0
—-
A1
—-
B1
pr$_vtag
D1
—-
F1
pr$_bcdecc
A2
pr$_neocmd
B2
pr$_vdata
D2
pr$_pcadr
F2
pr$_bcetsts
A3
—-
B3
pr$_icsr
D3
—-
F3
pr$_bcetidx
A4
pr$_nedathi
B4
—-
D4
pr$_pcsts
F4
pr$_bcetag
A5
—-
B5
—-
D5
—-
F5
pr$_bcedsts
A6
pr$_nedatlo
B6
—-
D6
—-
F6
pr$_bcedidx
A7
—-
B7
pr$_pamode
E7
—-
F7
pr$_bcedecc
A8
pr$_neicmd
B8
—-
E8
pr$_pcctl
F8
pr$_cefadr
AB
—-
B9
—-
E9
—-
F9
pr$_cefsts
AC
—-
BA
pr$_tbadr
EC
—-
FA
pr$_nests
AE
—-
BB
pr$_tbsts
ED
—-
FB
pr$_bctag
01000000
pr$_bcflush
01400000
pr$_pctag
01800000
pr$_pcdap
01C00000
/P—Physical (VAX I/O Space)
qbio
20000000
qbmem
30000000
qbmbr
20080010
—-
—-
rom
20040000
—-
—-
bdr
20084004
—-
—-
scr
20080000
dser
20080004
qbear
20080008
dear
2008000C
ipcr0
20001f40
ipcr1
20001f42
ipcr2
20001f44
ipcr3
20001f46
ssc_ram
20140400
ssc_cr
20140010
ssc_cbtcr
20140020
ssc_dledr
20140030
A–4 KA675/KA680/KA690 CPU
Table A–1 (Cont.): Console Symbolic Addresses
Symb
Addr
Symb
Addr
Symb
Addr
Symb
Addr
ssc_ad0mat
20140130
ssc_ad0msk
20140134
ssc_ad1mat
20140140
ssc_ad1msk
20140144
ssc_tcr0
20140100
ssc_tir0
20140104
ssc_tnir0
20140108
ssc_tivr0
2014010c
ssc_tcr1
20140110
ssc_tir1
20140114
ssc_tnir1
20140118
ssc_tivr1
2014011c
nicsr0
20008000
nicsr1
20008004
nicsr2
20008008
nicsr3
2000800C
nicsr4
20008010
nicsr5
20008014
nicsr6
20008018
nicsr7
2000801C
—-
20008020
nicsr9
20008024
nicsr10
20008028
nicsr11
2000802C
nicsr12
20008030
nicsr13
20008034
nicsr14
20008038
nicsr15
2000803C
sgec_setup
20008000
sgec_txpoll
20008004
sgec_rxpoll
20008008
sgec_rba
2000800C
sgec_tba
20008010
sgec_status
20008014
sgec_mode
20008018
sgec_sbr
2000801C
—-
20008020
sgec_wdt
20008024
sgec_mfc
20008028
sgec_verlo
2000802C
sgec_verhi
20008030
sgec_proc
20008034
sgec_bpt
20008038
sgec_cmd
2000803C
/P—Physical (VAX I/O Space)
shac1_sswcr
20004030
shac1_sshma
20004044
shac1_pqbbr
20004048
shac1_psr
2000404c
shac1_pesr
20004050
shac1_pfar
20004054
shac1_ppr
20004058
shac1_pmcsr
2000405C
20004084
shac1_pcq0cr
20004080
shac1_pcq1cr
shac1_pcq2cr
20004088
shac1_pcq3cr
2000408C
shac1_pdfqcr
20004090
shac1_pmfqcr 20004094
shac1_psrcr
20004098
shac1_pecr
2000409C
shac1_pdcr
200040A0
shac1_picr
shac1_pmtcr
200040A8
shac1_pmtecr 200040AC
200040A4
shac2_sswcr
20004230
shac2_sshma
20004244
shac2_pqbbr
20004248
shac2_psr
2000424c
shac2_pesr
20004250
shac2_pfar
20004254
shac2_ppr
20004258
shac2_pmcsr
2000425C
20004284
shac2_pcq0cr
20004280
shac2_pcq1cr
shac2_pcq2cr
20004288
shac2_pcq3cr
2000428C
shac2_pdfqcr
20004290
shac2_pmfqcr 20004294
shac2_psrcr
20004298
shac2_pecr
2000429C
shac2_pdcr
200042A0
shac2_picr
shac2_pmtcr
200042A8
shac2_pmtecr 200042AC
200042A4
shac_sswcr
20004230
shac_sshma
20004244
shac_pqbbr
20004248
shac_psr
2000424c
shac_pesr
20004250
shac_pfar
20004254
shac_ppr
20004258
shac_pmcsr
2000425C
shac_pcq0cr
20004280
shac_pcq1cr
20004284
shac_pcq2cr
20004288
shac_pcq3cr
2000428C
shac_pdfqcr
20004290
shac_pmfqcr
20004294
shac_psrcr
20004298
shac_pecr
2000429C
shac_pdcr
200042A0
shac_picr
200042A4
shac_pmtcr
200042A8
shac_pmtecr
200042AC
nmccwb
21000110
—-
—-
—-
—-
—-
—-
memcon0
21018000
memcon1
21018004
memcon2
21018008
memcon3
2101800c
memcon4
21018010
memcon5
21018014
memcon6
21018018
memcon7
2101801c
memsig8
21018020
memsig9
21018024
memsig10
21018028
memsig11
2101802c
memsig12
21018030
memsig13
21018034
memsig14
21018038
memsig15
2101803c
mear
21018040
mser
21018044
nmcdsr
21018048
moamr
2101804C
cear
21020000
ncadsr
21020004
csear1
21020008
csear2
2102000c
cpioea1
21020010
cpioar2
21020014
ndear
21020018
—-
—-
KA675/KA680/KA690 Firmware Commands
A–5
Table A–2 lists symbolic addresses that you can use in any address space.
Table A–2: Symbolic Addresses Used in Any Address Space
Symbol
Description
*
+
The location last referenced in an EXAMINE or DEPOSIT command.
The location immediately following the last location referenced in an EXAMINE
or DEPOSIT command. For references to physical or virtual memory spaces, the
location referenced is the last address, plus the size of the last reference (1 for
byte, 2 for word, 4 for longword, 8 for quadword). For other address spaces, the
address is the last address referenced plus one.
The location immediately preceding the last location referenced in an EXAMINE
or DEPOSIT command. For references to physical or virtual memory spaces,
the location referenced is the last address minus the size of this reference (1 for
byte, 2 for word, 4 for longword, 8 for quadword). For other address spaces, the
address is the last address referenced minus one.
The location addressed by the last location referenced in an EXAMINE or
DEPOSIT command.
_
@
A.1.4 Console Numeric Expression Radix Specifiers
By default, the console treats any numeric expression used as an address
or a datum as a hexadecimal integer. The user may override the default
radix by using one of the specifiers listed in Table A–3.
Table A–3: Console Radix Specifiers
Form 1
Form 2
Radix
%b
^b
Binary
%o
^o
Octal
%d
^d
Decimal
%x
^x
Hexadecimal, default
For instance, the value 19 is by default hexadecimal, but it may also be
represented as %b11001, %o31, %d25, and %x19 (or in the alternate form
as ^b11001, ^o31, ^d25, and ^x19).
A.1.5 Console Command Qualifiers
You can enter console command qualifiers in any order on the command
line after the command keyword. The three types of qualifiers are data
control, address space control, and command specific. Table A–4 lists and
A–6 KA675/KA680/KA690 CPU
describes the data control and address space control qualifiers. Command
specific qualifiers are listed in the descriptions of individual commands.
Table A–4: Console Command Qualifiers
Qualifier
Description
Data Control
/B
/W
/L
/Q
/N:{count}
/STEP:{size}
/WRONG
The data size is byte.
The data size is word.
The data size is longword.
The data size is quadword.
An unsigned hexadecimal integer that is evaluated into a longword. This
qualifier determines the number of additional operations that are to take place
on EXAMINE, DEPOSIT, MOVE, and SEARCH commands. An error message
appears if the number overflows 32 bits.
Step. Overrides the default increment of the console current reference.
Commands that manipulate memory, such as EXAMINE, DEPOSIT, MOVE,
and SEARCH, normally increment the console current reference by the size
of the data being used.
Wrong. On writes, 3 is used as the value of the ECC bits, which always
generates double bit errors. Ignores ECC errors on main memory reads.
Address Space Control
/G
/I
/V
/P
/M
/U
General purpose register (GPR) address space, R0–R15. The data size is
always longword.
Internal processor register (IPR) address space. Accessible only by the MTPR
and MFPR instructions. The data size is always longword.
Virtual memory address space. All access and protection checking occur. If
access to a program running with the current PSL is not allowed, the console
issues an error message. Deposits to virtual space cause the PTE<M> bit to be
set. If memory mapping is not enabled, virtual addresses are equal to physical
addresses. Note that when you examine virtual memory, the address space
and address in the response is the physical address of the virtual address.
Physical memory address space.
Processor status longword (PSL) address space. The data size is always
longword.
Access to console private memory is allowed. This qualifier also disables
virtual address protection checks. On virtual address writes, the PTE<M>
bit is not set if the /U qualifier is present. This qualifier is not inherited; it
must be respecified on each command.
KA675/KA680/KA690 Firmware Commands
A–7
A.1.6 Console Command Keywords
Table A–5 lists command keywords by type. Table A–6 lists the parameters,
qualifiers, and arguments for each console command. Parameters, used
with the SET and SHOW commands only, are listed in the first column
along with the command.
You should not use abbreviations in programs. Although it is possible
to abbreviate by using the minimum number of characters required to
uniquely identify a command or parameter, these abbreviations may
become ambiguous at a later time if an updated version of the firmware
contains new commands or parameters.
Table A–5: Command Keywords by Type
Processor Control
Data Transfer
Console Control
BOOT
CONTINUE
HALT
INITIALIZE
NEXT
START
UNJAM
DEPOSIT
EXAMINE
MOVE
SEARCH
X
CONFIGURE
FIND
REPEAT
SET
SHOW
TEST
!
Table A–6: Console Command Summary
Command
Qualifiers
Argument
Other(s)
BOOT
/R5:{boot_flags} /{boot_flags}
[{boot_device}[,{boot_device}]...]
—
CONFIGURE
—
—
—
CONTINUE
—
—
—
DEPOSIT
/B /W /L /Q — /G /I /V /P /M /U
/N:{count} /STEP:{size} /WRONG
{address}
{data} [{data}]
EXAMINE
/B /W /L /Q — /G /I /V /P /M /U
/N:{count} /STEP:{size} /WRONG
[{address}]
—
/INSTRUCTION
FIND
/MEM /RPB
—
—
HALT
—
—
—
HELP
—
—
—
INITIALIZE
—
—
—
MOVE
/B /W /L /Q — /V /P /U
/N:{count} /STEP:{size} /WRONG
{src_address}
{dest_address}
NEXT
—
[{count}]
—
REPEAT
—
{command}
—
A–8 KA675/KA680/KA690 CPU
Table A–6 (Cont.): Console Command Summary
Command
Qualifiers
Argument
Other(s)
SEARCH
/B /W /L /Q — /V /P /U
/N:{count} /STEP:{size} /WRONG
{start_address}
{pattern} [{mask}]
SET BFLAG
—
{bitmap}
—
SET BOOT
—
[{boot_device}[,{boot_device}]...
—
SET CONTROLP
—
{0/1}
—
SET HALT
—
{halt_action}
—
SET HOST
/DUP /DSSI /BUS:{0/1}
{node_number}
[{task}]
SET HOST
/DUP /UQSSP {/DISK ! /TAPE }
/DUP /UQSSP
{controller_number}
{csr_address}
[{task}]
[{task}]
SET HOST
/MAINTENANCE /UQSSP
/SERVICE
/MAINTENANCE /UQSSP
{controller_number}
{csr_address}
SET LANGUAGE
—
{language_type}
—
SET RECALL
—
{0/1}
—
SHOW BFL(A)G
—
—
—
SHOW BOOT
—
—
—
SHOW CONTROLP —
—
—
SHOW DSSI
—
—
—
SHOW HALT
—
—
—
SHOW LANGUAGE —
—
—
SHOW MEMORY
/FULL
—
—
SHOW QBUS
—
—
—
SHOW RECALL
—
—
—
SHOW RLV12
—
—
—
SHOW SCSI
—
—
—
SHOW TRANSLATION
—
{phys_address}
—
SHOW UQSSP
—
—
—
SHOW VERSION
—
—
—
START
—
{address}
—
TEST
—
{test_number}
[{parameters}]
UNJAM
—
—
—
X
—
{address}
{count}
/NOT
A.2 Console Commands
This section describes the console I/O mode commands.
commands at the console I/O mode prompt (>>>).
Enter the
KA675/KA680/KA690 Firmware Commands
A–9
A.2.1 BOOT
The BOOT command initializes the processor and transfers execution to
VMB. VMB attempts to boot the operating system from the specified device
or list of devices, or from the default boot device if none is specified. The
console qualifies the bootstrap operation by passing a boot flags bitmap to
VMB in R5.
Format:
BOOT [qualifier-list] [{boot_device},{boot_device},...]
If you do not enter either the qualifier or the device name, the default value
is used. Explicitly stating the boot flags or the boot device overrides, but
does not permanently change, the corresponding default value.
When specifying a list of boot devices (up to 32 characters, with devices
separated by commas and no spaces), the system checks the devices in the
order specified and boots from the first one that contains bootable software.
NOTE: If included in a string of boot devices, the Ethernet device, EZA0,
should be placed only as the last device of the string. The system will
continuously attempt to boot from EZA0.
Set the default boot device and boot flags with the SET BOOT and SET
BFLAG commands. If you do not set a default boot device, the processor
times out after 30 seconds and attempts to boot from the Ethernet port,
EZA0.
Qualifiers:
Command specific:
/R5:{boot_flags} A 32-bit hex value passed to VMB in R5. The console does not interpret this
value. Use the SET BFLAG command to specify a default boot flags longword.
Use the SHOW BFLAG command to display the longword. Table 3–4 lists the
supported R5 boot flags.
/{boot_flags}
Same as /R5:{boot_flags}
[device_name] A character string of up to 32 characters. Longer strings cause a VAL TOO
BIG error message. When specifying a list of boot devices, the device names
should be separated by commas and no spaces. Apart from checking the
length, the console does not interpret or validate the device name. The console
converts the string to uppercase, then passes VMB a string descriptor to this
device name in R0. Use the SET BOOT command to specify a default boot
device or list of devices. Use the SHOW BOOT command to display the default
boot device. The factory default device is the Ethernet port, EZA0. Table 3–3
lists the boot devices supported by the KA675/KA680/KA690.
Examples:
A–10 KA675/KA680/KA690 CPU
>>>SHOW BOOT
DUA0
>>>SHOW BFLAG
00000000
>>>B
!Boot using default boot flags and device.
(BOOT/R5:0 DUAO)
2..
-DUA0
>>>BO XQA0 !Boot using default boot flags and
(BOOT/R5:0 XQA0)
!specified device.
2..
-XQA0
>>>BOOT I/O !Boot using specified boot flags and
(BOOT/R5:10 DUAO)
!default device.
2..
-DUAO
>>>BOOT /R5:220 XQA0 !Boot using specified boot
(BOOT/R5:220 XQA0)
! flags and device.
2..
-XQA0
A.2.2 CONFIGURE
The CONFIGURE command invokes an interactive mode that permits
you to enter Q22–bus device names, then generates a table of Q22–bus
I/O page device CSR addresses and interrupt vectors. CONFIGURE is
similar to the VMS SYSGEN CONFIG utility. This command simplifies
field configuration by providing information that is typically available only
with a running operating system. Refer to the example below and use the
CONFIGURE command as follows:
1. Enter CONFIGURE at the console I/O prompt.
2. Enter HELP at the Device,Number? prompt to see a list of devices
whose CSR addresses and interrupt vectors can be determined.
3. Enter the device names and number of devices.
4. Enter EXIT to obtain the CSR address and interrupt vector
assignments.
The devices listed in the HELP display are not necessarily supported by
the CPU.
Format:
KA675/KA680/KA690 Firmware Commands
A–11
CONFIGURE
A–12 KA675/KA680/KA690 CPU
Example:
>>>CONFIGURE
Enter device configuration, HELP, or EXIT
Device,Number? help
Devices:
LPV11
KXJ11
DLV11J
DZQ11
RLV12
TSV05
RXV21
DRV11W
DMV11
DELQA
DEQNA
DESQA
RRD50
RQC25
KFQSA-DISK
TQK50
RV20
KFQSA-TAPE
KMV11
IEQ11
CXA16
CXB16
CXY08
VCB01
LNV21
QPSS
DSV11
ADV11C
KWV11C
ADV11D
AAV11D
VCB02
DRQ3B
VSV21
IBQ01
IDV11A
IDV11D
IAV11A
IAV11B
MIRA
DESNA
IGQ11
DIV32
KIV32
KWV32
KZQSA
Numbers:
1 to 255, default is 1
Device,Number? rqdx3,2
Device,Number? dhv11,2
Device,Number? deqna
Device,Number? kfqsa-tape
Device,Number? cxy08
Device,Number? mira
Device,Number? tqk50
Device,Number? tqk70
Device,Number? dhq11
Device,Number? lnv11
Device,Number? exit
DZV11
DRV11B
RQDX3
TQK70
DHQ11
QVSS
AAV11C
QDSS
IDV11B
ADQ32
DTCN5
DFA01
DPV11
KDA50
TU81E
DHV11
LNV11
AXV11C
DRV11J
IDV11C
DTC04
DTC05
Address/Vector Assignments
-774440/120 DEQNA
-772150/154 RQDX3
-760334/300 RQDX3
-774500/260 KFQSA-TAPE
-760444/304 TQK50
-760450/310 TQK70
-760500/320 DHV11
-760520/330 DHV11
-760540/340 CXY08
-760560/350 DHQ11
-776200/360 LNV11
-761260/370 MIRA
>>>
KA675/KA680/KA690 Firmware Commands
A–13
A.2.3 CONTINUE
The CONTINUE command causes the processor to begin instruction
execution at the address currently contained in the PC. It does not perform
a processor initialization. The console enters program I/O mode.
Format:
CONTINUE
Example:
>>>CONTINUE
$
!VMS DCL prompt
A.2.4 DEPOSIT
The DEPOSIT command deposits data into the address specified. If you
do not specify an address space or data size qualifier, the console uses the
last address space and data size used in a DEPOSIT, EXAMINE, MOVE,
or SEARCH command. After processor initialization, the default address
space is physical memory, the default data size is longword, and the default
address is zero. If you specify conflicting address space or data sizes, the
console ignores the command and issues an error message.
Format:
DEPOSIT [qualifier-list] {address} {data} [data...]
Qualifiers:
Data control: /B, /W, /L, /Q, /N:{count}, /STEP:{size}, /WRONG
Address space control: /G, /I, /M, /P, /V, /U
Arguments:
{address}
A longword address that specifies the first location into which data is deposited.
The address can be an actual address or a symbolic address.
{data}
The data to be deposited. If the specified data is larger than the deposit data size,
the firmware ignores the command and issues an error response. If the specified
data is smaller than the deposit data size, it is extended on the left with zeros.
[{data}]
Additional data to be deposited (as many as can fit on the command line).
Examples:
>>>D/P/B/N:1FF 0 0
A–14 KA675/KA680/KA690 CPU
! Clear first 512 bytes of
! physical memory.
>>>D/V/L/N:3 1234 5
!
!
!
!
>>>D/N:8 R0 FFFFFFFF
Deposit 5 into four longwords
starting at virtual memory address
1234.
Loads GPRs R0 through R8 with -1.
>>>D/L/P/N:10/ST:200 0 8
! Deposit 8 in the first longword of
! the first 17 pages in physical
! memory.
>>>D/N:200 - 0
! Starting at previous address, clear
! 513 longwords or 2052 bytes.
A.2.5 EXAMINE
The EXAMINE command examines the contents of the memory location or
register specified by the address. If no address is specified, + is assumed.
The display line consists of a single character address specifier, the physical
address to be examined, and the examined data.
EXAMINE uses the same qualifiers as DEPOSIT. However, the /WRONG
qualifier causes EXAMINE to ignore ECC errors on reads from physical
memory. The EXAMINE command also supports an /INSTRUCTION
qualifier, which will disassemble the instructions at the current address.
Format:
EXAMINE [qualifier-list] [address]
Qualifiers:
Data control: /B, /W, /L, /Q, /N:{count}, /STEP:{size}, /WRONG
Address space control: /G, /I, /M, /P, /V, /U
Command specific:
/INSTRUCTION
Disassembles and displays the VAX MACRO–32 instruction at the specified
address.
Arguments:
[{address}]
A longword address that specifies the first location to be examined. The
address can be an actual or a symbolic address. If no address is specified,
+ is assumed.
KA675/KA680/KA690 Firmware Commands
A–15
Examples:
>>>EX PC
G 0000000F
>>>EX SP
G 0000000E
>>>EX PSL
M 00000000
>>>E/M
M 00000000
>>>E R4/N:5
G 00000004
G 00000005
G 00000006
G 00000007
G 00000008
G 00000009
! Examine the PC.
FFFFFFFC
! Examine the SP.
00000200
! Examine the PSL.
041F0000
! Examine PSL another way.
041F0000
! Examine R4 through R9.
00000000
00000000
00000000
00000000
00000000
801D9000
>>>EX PR$_SCBB
I 00000011 2004A000
!Examine the SCBB, IPR 17
! (decimal).
>>>E/P 0
P 00000000 00000000
! Examine local memory 0.
>>>EX /INS 20040000
P 20040000
11 BRB
! Examine 1st byte of ROM.
20040019
>>>EX /INS/N:5
P 20040019
P 20040024
P 2004002F
P 20040036
P 2004003D
P 20040044
20040019
D0 MOVL
D2 MCOML
D2 MCOML
7D MOVQ
D0 MOVL
DB MFPR
! Disassemble from branch.
I^#20140000,@#20140000
@#20140030,@#20140502
S^#0E,@#20140030
R0,@#201404B2
I^#201404B2,R1
S^#2A,B^44(R1)
>>>E/INS
P 20040048
DB MFPR
! Look at next instruction.
S^#2B,B^48(R1)
>>>
A.2.6 FIND
The FIND command searches main memory, starting at address zero for
a page-aligned 128-Kbyte segment of good memory, or a restart parameter
block (RPB). If the command finds the segment or RPB, its address plus
512 is left in SP (R14). If it does not find the segment or RPB, the console
issues an error message and preserves the contents of SP. If you do not
specify a qualifier, /RPB is assumed.
Format:
FIND [qualifier-list]
A–16 KA675/KA680/KA690 CPU
Qualifiers:
Command specific:
/MEMORY Searches memory for a page-aligned block of good memory, 128 Kbytes in length.
The search looks only at memory that is deemed usable by the bitmap. This
command leaves the contents of memory unchanged.
/RPB
Searches all physical memory for an RPB. The search does not use the bitmap to
qualify which pages are looked at. The command leaves the contents of memory
unchanged.
Examples:
>>>EX SP
G 0000000E 00000000
>>>FIND /MEM
>>>EX SP
G 0000000E 00000200
>>>FIND /RPB
?2C FND ERR 00C00004
>>>
! Check the SP.
! Look for a valid 128 Kbytes.
! Note where it was found.
! Check for valid RPB.
! None to be found here.
A.2.7 HALT
The HALT command has no effect. It is included for compatibility with
other VAX consoles.
Format:
HALT
Example:
>>>HALT
>>>
! Pretend to halt.
A.2.8 HELP
The HELP command provides information about command syntax and
usage.
Format:
HELP
Example:
>>>HELP
Following is a brief summary of all the commands supported by the
console:
KA675/KA680/KA690 Firmware Commands
A–17
UPPERCASE
|
[]
<>
..
...
denotes
denotes
denotes
denotes
denotes
denotes
a keyword that you must type in
an OR condition
optional parameters
a field specifying a syntactically correct value
one of an inclusive range of integers
that the previous item may be repeated
Valid qualifiers:
/B /W /L /Q /INSTRUCTION
/G /I /V /P /M
/STEP: /N: /NOT
/WRONG /U
Valid commands:
BOOT [[/R5:]<boot_flags>] [<boot_device>]
CONFIGURE
CONTINUE
DEPOSIT [<qualifiers>] <address> <datum> [<datum>...]
EXAMINE [<qualifiers>] [<address>]
FIND [/MEMORY | /RPB]
HALT
HELP
INITIALIZE
MOVE [<qualifiers>] <address> <address>
NEXT [<count>]
REPEAT <command>
SEARCH [<qualifiers>] <address> <pattern> [<mask>]
SET BFLG <boot_flags>
SET BOOT <boot_device>
SET CONTROLP <0..1 |DISABLED|ENABLED>
SET HALT <0..4 |DEFAULT|RESTART|REBOOT|HALT|RESTART_REBOOT>
SET HOST/DUP/DSSI/BUS:<0..1> <node_number> [<task>]
SET HOST/DUP/UQSSP </DISK|/TAPE> <controller_number>[<task>]
SET HOST/DUP/UQSSP <physical_CSR_address> [<task>]
SET HOST/MAINTENANCE/UQSSP/SERVICE <controller_number>
SET HOST/MAINTENANCE/UQSSP <physical_CSR_address>
SET LANGUAGE <1..15>
SET RECALL <0..1 | DISABLED | ENABLED>
SHOW BFLG
SHOW BOOT
SHOW CONTROLP
SHOW DEVICE
SHOW DSSI
SHOW ETHERNET
SHOW HALT
SHOW LANGUAGE
SHOW MEMORY [/FULL]
SHOW QBUS
SHOW RECALL
SHOW RLV12
SHOW SCSI
A–18 KA675/KA680/KA690 CPU
SHOW TRANSLATION <physical_address>
SHOW UQSSP
SHOW VERSION
START <address>
TEST [<test_code> [<parameters>]]
UNJAM
X <address> <count>
>>>
A.2.9 INITIALIZE
The INITIALIZE command performs a processor initialization.
Format:
INITIALIZE
The following registers are initialized:
Register
State at Initialization
PSL
IPL
ASTLVL
SISR
ICCS
RXCS
TXCS
MAPEN
Caches
Instruction buffer
Console previous reference
TODR
Main memory
General registers
Halt code
Bootstrap-in-progress flag
Internal restart-in-progress flag
041F0000
1F
4
0
Bits <6> and <0> clear; the rest are unpredictable
0
80
0
Flushed
Unaffected
Longword, physical, address 0
Unaffected
Unaffected
Unaffected
Unaffected
Unaffected
Unaffected
The firmware clears all error status bits and initializes the following:
CDAL bus timer
Address decode and match registers
Programmable timer interrupt vectors
SSCCR
KA675/KA680/KA690 Firmware Commands
A–19
Example:
>>>INIT
>>>
A.2.10 MOVE
The MOVE command copies the block of memory starting at the source
address to a block beginning at the destination address. Typically, this
command has an /N qualifier so that more than one datum is transferred.
The destination correctly reflects the contents of the source, regardless of
the overlap between the source and the data.
The MOVE command actually performs byte, word, longword, and
quadword reads and writes as needed in the process of moving the data.
Moves are supported only for the physical and virtual address spaces.
Format:
MOVE [qualifier-list] {src_address} {dest_address}
Qualifiers:
Data control: /B, /W, /L, /Q, /N:{count}, /STEP:{size}, /WRONG
Address space control: /V, /U, /P
Arguments:
{src_address}
A longword address that specifies the first location of the source data to be
copied.
{dest_address}
A longword address that specifies the destination of the first byte of data.
These addresses may be an actual address or a symbolic address. If no
address is specified, + is assumed.
A–20 KA675/KA680/KA690 CPU
Examples:
>>>EX/N:4 0
P 00000000 00000000
P 00000004 00000000
P 00000008 00000000
P 0000000C 00000000
P 00000010 00000000
! Observe destination.
>>>EX/N:4 200
P 00000200 58DD0520
P 00000204 585E04C1
P 00000208 00FF8FBB
P 0000020C 5208A8D0
P 00000210 540CA8DE
! Observe source data.
>>>MOV/N:4 200 0
! Move the data.
>>>EX/N:4 0
P 00000000 58DD0520
P 00000004 585E04C1
P 00000008 00FF8FBB
P 0000000C 5208A8D0
P 00000010 540CA8DE
>>>
! Observe moved data.
A.2.11 NEXT
The NEXT command executes the specified number of macro instructions.
If no count is specified, 1 is assumed.
After the last macro instruction is executed, the console reenters console
I/O mode.
Format:
NEXT {count}
The console implements the NEXT command, using the trace trap enable
and trace pending bits in the PSL and the trace pending vector in the SCB.
The console enters the "Spacebar Step Mode". In this mode, subsequent
spacebar strokes initiate single steps and a carriage return forces a return
to the console prompt.
The following restrictions apply:
•
If memory management is enabled, the NEXT command works only if
the first page in SSC RAM is mapped in S0 (system) space.
•
Overhead associated with the NEXT command affects execution time
of an instruction.
KA675/KA680/KA690 Firmware Commands
A–21
•
The NEXT command elevates the IPL to 31 for long periods of time
(milliseconds) while single-stepping over several commands.
•
Unpredictable results occur if the macro instruction being stepped over
modifies either the SCBB or the trace trap entry. This means that you
cannot use the NEXT command in conjunction with other debuggers.
Arguments:
{count}
A value representing the number of macro instructions to execute.
Examples:
>>>DEP 1000 50D650D4
! Create a simple program.
>>>DEP 1004 125005D1
>>>DEP 1008 00FE11F9
>>>EX /INSTRUCTION /N:5 1000
! List it.
P 00001000
D4 CLRL
R0
P 00001002
D6 INCL
R0
P 00001004
D1 CMPL
S^#05,R0
P 00001007
12 BNEQ
00001002
P 00001009
11 BRB
00001009
P 0000100B
00 HALT
>>>DEP PR$_SCBB 200
! Set up a user SCBB...
>>>DEP PC 1000
! ...and the PC.
>>>
>>>N
! Single step...
P 00001002
D6 INCL
R0
! SPACEBAR
P 00001004
D1 CMPL
S^#05,R0
! SPACEBAR
P 00001007
12 BNEQ
00001002
! SPACEBAR
P 00001002
D6 INCL
R0
! CR
>>>N 5
! ...or multiple step the program.
P 00001004
D1 CMPL
S^#05,R0
P 00001007
12 BNEQ
00001002
P 00001002
D6 INCL
R0
P 00001004
D1 CMPL
S^#05,R0
P 00001007
12 BNEQ
00001002
>>>N 7
P 00001002
D6 INCL
R0
P 00001004
D1 CMPL
S^#05,R0
P 00001007
12 BNEQ
00001002
P 00001002
D6 INCL
R0
P 00001004
D1 CMPL
S^#05,R0
P 00001007
12 BNEQ
00001002
P 00001009
11 BRB
00001009
>>>N
P 00001009
11 BRB
00001009
>>>
A–22 KA675/KA680/KA690 CPU
A.2.12 REPEAT
The REPEAT command repeatedly displays and executes the specified
command. Press CTRL/C to stop the command. You can specify any valid
console command except the REPEAT command.
Format:
REPEAT {command}
Arguments:
{command} A valid console command other than REPEAT.
Examples:
>>>REPEAT EX
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
I 0000001B
>>>
PR$_TODR !Watch the clock.
5AFE78CE
5AFE78D1
5AFE78FD
5AFE7900
5AFE7903
5AFE7907
5AFE790A
5AFE790D
5AFE7910
5AFE793C
5AFE793F
5AFE7942
5AFE7946
5AFE7949
5AFE794C
5AFE794F
5^C
A.2.13 SEARCH
The SEARCH command finds all occurrences of a pattern and reports the
addresses where the pattern was found. If the /NOT qualifier is present,
the command reports all addresses in which the pattern did not match.
Format:
SEARCH [qualifier-list] {address} {pattern} [{mask}]
SEARCH accepts an optional mask that indicates bits to be ignored (don’t
care bits). For example, to ignore bit 0 in the comparison, specify a mask
of 1. The mask, if not present, defaults to 0.
KA675/KA680/KA690 Firmware Commands
A–23
A match occurs if (pattern and not mask) = (data and not mask), where:
Pattern is the target data
Mask is the optional don’t care bitmask (which defaults to 0)
Data is the data at the current address
SEARCH reports the address under the following conditions:
/NOT Qualifier
Match Condition
Action
Absent
Absent
Present
Present
True
False
True
False
Report address
No report
No report
Report address
The address is advanced by the size of the pattern (byte, word, longword,
or quadword), unless overridden by the /STEP qualifier.
Qualifiers:
Data control: /B, /W, /L, /Q, /N:{count}, /STEP:{size}, /WRONG
Address space control: /P, /V, /U
Command specific:
/NOT
Inverts the sense of the match.
Arguments:
{start_address} A longword address that specifies the first location subject to the search. This
address can be an actual address or a symbolic address. If no address is
specified, + is assumed.
{pattern}
The target data.
[{mask}]
A mask of the bits desired in the comparison.
Examples:
>>>DEP /P/L/N:1000 0 0
>>>
>>>DEP 300 12345678
>>>DEP 401 12345678
>>>DEP 502 87654321
>>>
>>>SEARCH /N:1000 /ST:1 0 12345678
P 00000300 12345678
P 00000401 12345678
>>>SEARCH /N:1000 0 12345678
P 00000300 12345678
>>>SEARCH /N:1000 /NOT 0 0
P 00000300 12345678
A–24 KA675/KA680/KA690 CPU
! Clear some memory.
! Deposit some search data.
!
!
!
!
!
!
Search for all occurrences
of 12345678 on any byte
boundary. Then try on
longword boundaries.
Search for all non-zero
longwords.
P 00000400 34567800
P 00000404 00000012
P 00000500 43210000
P 00000504 00008765
>>>SEARCH /N:1000 /ST:1 0 1 FFFFFFFE
P 00000502 87654321
P 00000503 00876543
P 00000504 00008765
P 00000505 00000087
>>>SEARCH /N:1000 /B 0 12
P 00000303 12
P 00000404 12
>>>SEARCH /N:1000 /ST:1 /w 0 FE11
>>>
>>>
>>>
! Search for odd-numbered
! longwords on any boundary.
! Search for all occurrences
! of the byte 12.
!
!
!
!
Search for all words that
could be interpreted as
a spin (10$: brb 10$).
Note that none were found.
A.2.14 SET
The SET command sets the parameter to the value you specify.
Format:
SET {parameter} {value}
Parameters:
BFLAG
Sets the default R5 boot flags. The value must be a hex number of up
to eight digits. See Table 3–4 for a list of the boot flags.
BOOT
Sets the default boot device. The value must be a valid device name or
list of device names as specified in the BOOT command description in
Section A.2.1.
CONTROLP
Sets Control-P as the console halt condition, instead of a BREAK.
Values of 1 or Enabled set Control-P recognition. Values of 0 or Disabled
set BREAK recognition. In either case, the setting of the Break Enable
/Disable switch.
HALT
Sets the user-defined halt action. Acceptable values are the keywords
"default", "restart", "reboot", "halt", "restart_reboot", or a number in the
range 0 to 4 inclusive.
HOST
Connects to the DUP or MAINTENANCE driver on the selected node
or device. The KA675/KA680/KA690 DUP driver supports only "send
data immediate" messages and those devices that support the messages.
It does not support "send data" or "receive data" messages. Note the
hierarchy of the SET HOST qualifiers below.
KA675/KA680/KA690 Firmware Commands
A–25
/DUP—Uses the DUP driver to examine or modify parameters of a
device on either the DSSI bus or on the Q22–bus.
/BUS:n—Selects the desired DSSI bus. A value of 0 selects DSSI
bus 0 (internal backplane bus). A value of 1 selects DSSI bus 1
(external console module bus).
/DSSI node—Selects the DSSI node, where "node" is a number
from 0 to 7.
/UQSSP—Attaches to the UQSSP device specified, using one of
the following methods:
/DISK n—Specifies the disk controller number, where n is a
number from 0 to 255. The resulting fixed address for n=0 is
20001468 and the floating rank for n>0 is 26.
/TAPE n—Specifies the tape controller number, where n is a
number from 0 to 255. The resulting fixed address for n=0 is
20001940 and the floating rank for n>0 is 30.
csr_address—Specifies the Q22–bus I/O page CSR address
for the device.
/MAINTENANCE—Examines and modifies the KFQSA EEPROM
configuration values. Does not accept a task value.
/UQSSP—
/SERVICE n—Specifies service for KFQSA controller module
n where n is a value from 0 to 3. (The resulting fixed
address of a KFQSA controller module in maintenance mode
is 20001910+4*n.)
/csr_address—Specifies the Q22–bus I/O page CSR address
for the KFQSA controller module.
LANGUAGE
Sets console language and keyboard type. If the current console
terminal does not support the multinational character set (MCS), then
this command has no effect and the console message appears in English.
Values are 1 through 15. Refer to Example 4–1 for the languages you
can select.
RECALL
Sets command recall state to either ENABLED (1) or DISABLED (0).
Qualifiers: Listed in the parameter descriptions above.
A–26 KA675/KA680/KA690 CPU
Examples:
>>>
>>>SET BFLAG 220
>>>
>>>SET BOOT DUA0
>>>
>>>SET HOST/DUP/DSSI 0
Starting DUP server...
DSSI Node 0 (SUSAN)
Copyright © 1990 Digital Equipment Corporation
DRVEXR V1.0 D 5-JUL-1990 15:33:06
DRVTST V1.0 D 5-JUL-1990 15:33:06
HISTRY V1.0 D 5-JUL-1990 15:33:06
ERASE V1.0 D 5-JUL-1990 15:33:06
PARAMS V1.0 D 5-JUL-1990 15:33:06
DIRECT V1.0 D 5-JUL-1990 15:33:06
End of directory
Task Name?PARAMS
Copyright © 1990
Digital Equipment Corporation
PARAMS>STAT PATH
ID
-0
6
1
4
5
2
3
Path Block
-----------PB FF811ECC
PB FF811FD0
PB FF8120D4
PB FF8121D8
PB FF8122DC
PB FF8123E0
PB FF8124E4
Remote Node
--------------Internal Path
KFQSA KFX V1.0
KAREN RFX V101
WILMA RFX V101
BETTY RFX V101
DSSI1 VMS V5.0
3
VMB BOOT
DGS_S DGS_R
MSGS_S MSGS_R
------ ------- ------- -------0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
14328
14328
0
0
61
61
PARAMS>EXIT
Exiting...
Task Name?
Stopping DUP server...
>>>
>>>SET HOST/DUP/DSSI/BUS:0 0 PARAMS
Starting DUP server...
DSSI Node 0 (SUSAN)
Copyright © 1990 Digital Equipment Corporation
PARAMS>SHOW NODE
Parameter Current
--------- ---------NODENAME
SUSAN
Default
Type
-------- -------RF71
String
Radix
--------Ascii
B
KA675/KA680/KA690 Firmware Commands
A–27
PARAMS>SHOW ALLCLASS
Parameter Current
--------- ---------ALLCLASS
1
Default
Type
--------- ------0
Byte
Radix
---------Dec
B
PARAMS>EXIT
Exiting...
Stopping DUP server...
>>>
>>>SET HOST/MAINT/UQSSP 20001468
UQSSP Controller (772150)
Enter SET, CLEAR, SHOW, HELP, EXIT, or QUIT
Node
CSR Address
Model
0
772150
21
1
760334
21
4
760340
21
5
760344
21
7
------ KFQSA -----? help
Commands:
SET <node> /KFQSA
set KFQSA DSSI node number
SET <node> <CSR_address> <model>
enable a DSSI device
CLEAR <node>
disable a DSSI device
SHOW
show current configuration
HELP
print this text
EXIT
program the KFQSA
QUIT
don’t program the KFQSA
Parameters:
<node>
0 to 7
<CSR_address>
760010 to 777774
<model>
21 (disk) or 22 (tape)
? set 6 /kfqsa
? show
Node
CSR Address
Model
0
772150
21
1
760334
21
4
760340
21
5
760344
21
6
------ KFQSA -----? exit
Programming the KFQSA...
>>>
>>>SET LANGUAGE 5
>>>
>>>SET HALT RESTART
>>>
A–28 KA675/KA680/KA690 CPU
A.2.15 SHOW
The SHOW command displays the console parameter you specify.
Format:
SHOW {parameter}
Parameters:
BFLAG
Displays the default R5 boot flags.
BOOT
Displays the default boot device.
CONTROLP
Shows the current state of Control-P halt recognition, either Enabled
or Disabled.
DEVICE
Displays all devices in the system.
HALT
Shows the user-defined halt action.
DSSI
Shows the status of all nodes that can be found on the DSSI bus. For
each node on the DSSI bus, the console displays the node number, the
node name, and the boot name and type of the device, if available. The
command does not indicate the "bootability" of the device.
The node that issues the command reports a node name of "*".
The device information is obtained from the media type field of the
MSCP command GET UNIT STATUS. In the case where the node is not
running or is not capable of running an MSCP server, then no device
information is displayed.
ETHERNET
Displays hardware Ethernet address for all Ethernet adapters that can
be found. Displays as blank if no Ethernet adapter is present.
LANGUAGE
Displays console language and keyboard type.
Refer to the
corresponding SET LANGUAGE command for the meaning.
MEMORY
Displays main memory configuration board by board.
/FULL—Additionally, displays the normally inaccessible areas of
memory, such as the PFN bitmap pages, the console scratch memory
pages, the Q22–bus scatter-gather map pages. Also reports the
addresses of bad pages, as defined by the bitmap.
KA675/KA680/KA690 Firmware Commands
A–29
QBUS
Displays all Q22–bus I/O addresses that respond to an aligned word
read, and speculative device name information. For each address, the
console displays the address in the VAX I/O space in hex, the address
as it would appear in the Q22–bus I/O space in octal, and the word data
that was read in hex.
This command may take several minutes to complete. Press CTRL/C to
terminate the command. During execution, the command disables the
scatter-gather map.
RECALL
Shows the current state of command recall, either ENABLED or
DISABLED.
RLV12
Displays all RL01 and RL02 disks that appear on the Q22–bus.
UQSSP
Displays the status of all disks and tapes that can be found on the
Q22–bus that support the UQSSP protocol. For each such disk or
tape on the Q22–bus, the firmware displays the controller number, the
controller CSR address, and the boot name and type of each device
connected to the controller. The command does not indicate whether
the device contains a bootable image.
This information is obtained from the media type field of the MSCP
command GET UNIT STATUS. The console does not display device
information if a node is not running (or cannot run) an MSCP server.
SCSI
Shows any SCSI devices in the system (TLZ04 or RRD40-series.)
TRANSLATION
Shows any virtual addresses that map to the specified physical address.
The firmware uses the current values of page table base and length
registers to perform its search; it is assumed that page tables have
been properly built.
VERSION
Displays the current firmware version.
Qualifiers: Listed in the parameter descriptions above.
Examples:
>>>
>>>SHOW BFLAG
00000220
>>>
>>>SHOW BOOT
DUA0
>>>SHOW CONTROLP
>>>
>>>SHOW DEVICE
KA680-A Vn.n VMBn.n
A–30 KA675/KA680/KA690 CPU
DSSI Bus 0 Node
-DIA0 (RF71)
DSSI Bus 0 Node
-DIA1 (RF71)
DSSI Bus 0 Node
-DIA2 (RF71)
DSSI Bus 0 Node
DSSI Bus 1 Node
0 (R7CZZC)
1 (R7ALUC)
2 (R7EB3C)
6 (*)
7 (*)
SCSI Adapter 0 (761300), SCSI ID 7
-DKA100 (DEC TLZ04)
Ethernet Adapter
-EZA0 (08-00-2B-0B-29-14)
>>>
>>>SHOW DSSI
DSSI Bus 0 Node 0 (R7CZZC)
-DIA0 (RF71)
DSSI Bus 0 Node 1 (R7ALUC)
-DIA1 (RF71)
DSSI Bus 0 Node 2 (R7EB3C)
-DIA2 (RF71)
DSSI Bus 0 Node 6 (*)
DSSI Bus 1 Node 7 (*)
>>>
>>>SHOW ETHERNET
Ethernet Adapter
-EZA0 (08-00-2B-0B-29-14)
>>>
>>>SHOW HALT
restart
>>>
>>>SHOW LANGUAGE
English (United States/Canada)
>>>
>>>SHOW MEMORY
Memory 0: 00000000 to 01FFFFFF, 32MB, 0 bad pages
Memory 0: 02000000 to 03FFFFFF, 32MB, 0 bad pages
Total of 64MB, 0 bad pages, 128 reserved pages
>>>
>>>SHOW MEMORY/FULL
Memory 0: 00000000 to 01FFFFFF, 32MB, 0 bad pages
Memory 0: 02000000 to 03FFFFFF, 32MB, 0 bad pages
Total of 64MB, 0 bad pages, 128 reserved pages
Memory Bitmap
-00FF3C00 to 00FF3FFF, 8 pages
Console Scratch Area
-00FF4000 to 00FF7FFF, 32 pages
KA675/KA680/KA690 Firmware Commands
A–31
Q-bus Map
-0FF8000 to 0FFFFFF, 64 pages
Scan of Bad Pages
>>>
>>>SHOW QBUS
Scan of Qbus I/O Space
-20001920 (774440) = FF08 DELQA/DESQA
-20001922 (774442) = FF00
-20001924 (774444) = FF2B
-20001926 (774446) = FF08
-20001928 (774450) = FFD7
-2000192A (774452) = FF41
-2000192C (774454) = 0000
-2000192E (774456) = 1030
-20001F40 (777500) = 0020 IPCR
Scan of Qbus Memory Space
>>>
>>>SHOW RLV12
>>>
>>>SHOW SCSI
SCSI Adapter 0 (761300), SCSI ID 7
-DKA100 (DEC TLZ04)
>>>
>>>SHOW TRANSLATION 1000
V 80001000
>>>
>>>SHOW UQSSP
UQSSP Disk Controller 0 (772150)
-DUA0 (RF30)
UQSSP Disk Controller 1 (760334)
-DUB1 (RF30)
UQSSP Disk Controller 2 (760340)
-DUC4 (RF30)
UQSSP Disk Controller 3 (760344)
-DUD5 (RF30)
>>>
>>>
>>>SHOW VERSION
KA680-A Vn.n VMBn.n
>>>
A–32 KA675/KA680/KA690 CPU
A.2.16 START
The START command starts instruction execution at the address you
specify. If no address is given, the current PC is used. If memory mapping
is enabled, macro instructions are executed from virtual memory, and the
address is treated as a virtual address. The START command is equivalent
to a DEPOSIT to PC, followed by a CONTINUE. It does not perform a
processor initialization.
Format:
START [{address}]
Arguments:
[address]
The address at which to begin execution. This address is loaded into the user’s
PC.
Example:
>>>START 1000
A.2.17 TEST
The TEST command invokes a diagnostic test program specified by the test
number. If you enter a test number of 0 (zero), all tests allowed to be
executed from the console terminal are executed. The console accepts an
optional list of up to five additional hexadecimal arguments.
Refer to Chapter 5 for a detailed explanation of the diagnostics.
Format:
TEST [{test_number} [{test_arguments}]]
Arguments:
{test_number}
A two-digit hex number specifying the test to be executed.
{test_arguments}
Up to five additional test arguments. These arguments are accepted,
but they have no meaning to the console.
Example:
>>>TEST 0
66..65..64..63..62..61..60..59..58..57..56..55..54..53..52..51..
50..49..48..47..46..45..44..43..42..41..40..39..38..37..36..35..
34..33..32..31..30..29..28..27..26..25..24..23..22..21..20..19..
18..17..16..15..14..13..12..11..10..09..08..07..06..05..04..03..
KA675/KA680/KA690 Firmware Commands
A–33
A.2.18 UNJAM
The UNJAM command performs an I/O bus reset, by writing a 1 (one) to
IPR 55 (decimal).
Format:
UNJAM
Example:
>>>UNJAM
>>>
A.2.19 X—Binary Load and Unload
The X command is for use by automatic systems communicating with the
console.
The X command loads or unloads (that is, writes to memory, or reads from
memory) the specified number of data bytes through the console serial line
(regardless of console type) starting at the specified address.
Format:
X {address} {count} CR {line_checksum} {data} {data_checksum}
If bit 31 of the count is clear, data is received by the console and deposited
into memory. If bit 31 is set, data is read from memory and sent by the
console. The remaining bits in the count are a positive number indicating
the number of bytes to load or unload.
The console accepts the command upon receiving the carriage return.
The next byte the console receives is the command checksum, which is
not echoed. The command checksum is verified by adding all command
characters, including the checksum and separating space (but not including
the terminating carriage return, rubouts, or characters deleted by rubout),
into an 8-bit register initially set to zero. If no errors occur, the result is
zero. If the command checksum is correct, the console responds with the
input prompt and either sends data to the requester or prepares to receive
data. If the command checksum is in error, the console responds with an
error message. The intent is to prevent inadvertent operator entry into a
mode where the console is accepting characters from the keyboard as data,
with no escape mechanism possible.
If the command is a load (bit 31 of the count is clear), the console responds
with the input prompt (>>>), then accepts the specified number of bytes
of data for depositing to memory, and an additional byte of received data
checksum. The data is verified by adding all data characters and the
checksum character into an 8-bit register initially set to zero. If the final
A–34 KA675/KA680/KA690 CPU
content of the register is nonzero, the data or checksum are in error, and
the console responds with an error message.
If the command is a binary unload (bit 31 of the count is set), the console
responds with the input prompt (>>>), followed by the specified number of
bytes of binary data. As each byte is sent, it is added to a checksum register
initially set to zero. At the end of the transmission, the two’s complement
of the low byte of the register is sent.
If the data checksum is incorrect on a load, or if memory or line errors occur
during the transmission of data, the entire transmission is completed, then
the console issues an error message. If an error occurs during loading, the
contents of the memory being loaded are unpredictable.
The console represses echo while it is receiving the data string and
checksums.
The console terminates all flow control when it receives the carriage return
at the end of the command line in order to avoid treating flow control
characters from the terminal as valid command line checksums.
You can control the console serial line during a binary unload using control
characters ( CTRL/C , CTRL/S , CTRL/O , and so on). You cannot control the console
serial line during a binary load, since all received characters are valid
binary data.
The console has the following timing requirements:
•
It must receive data being loaded with a binary load command at a rate
of at least one byte every 60 seconds.
•
It must receive the command checksum that precedes the data within
60 seconds of the carriage return that terminates the command line.
•
It must receive the data checksum within 60 seconds of the last data
byte.
If any of these timing requirements are not met, then the console aborts
the transmission by issuing an error message and returning to the console
prompt.
The entire command, including the checksum, can be sent to the console
as a single burst of characters at the specified character rate of the console
serial line. The console is able to receive at least 4 Kbytes of data in a
single X command.
KA675/KA680/KA690 Firmware Commands
A–35
A.2.20 ! (Comment)
The comment character (an exclamation point) is used to document
command sequences. It can appear anywhere on the command line. All
characters following the comment character are ignored.
Format: !
Example:
>>>! The console ignores this line.
>>>
A–36 KA675/KA680/KA690 CPU
Appendix B
Address Assignments
B.1 KA675/KA680/KA690 General Local Address
Space Map
VAX Memory Space
---------------Address Range
----------------0000 0000 - 1FFF FFFF
Contents
-----------Local Memory Space (512MB)
VAX I/O Space
------------Address Range
----------------2000 0000 - 2000 1FFF
2000 2000 - 2003 FFFF
Contents
-----------Local Q22-Bus I/O Space (8KB)
Reserved Local I/O Space (248KB)
2008 0000
-
201F FFFF
Local Register I/O Space (1.5MB)
2020
2400
2008
2C08
0000
0000
0000
0000
-
23FF
27FF
2BFF
2FFF
Reserved
Reserved
Reserved
Reserved
3000 0000
3040 0000
3400 0000
-
303F FFFF
33FF FFFF
37FF FFFF
Local Q22-Bus Memory Space (4MB)
Reserved Local I/O Space (60MB)
Reserved Local I/O Space (64MB)
3800 0000
3C00 0000
-
3BFF FFFF
3FFF FFFF
Reserved Local I/O Space (64MB)
Reserved Local I/O Space (64MB)
E004 0000
-
E007 FFFF
Local ROM Space
FFFF
FFFF
FFFF
FFFF
Local
Local
Local
Local
I/O
I/O
I/O
I/O
Space
Space
Space
Space
(62.5MB)
(64MB)
(64MB)
(64MB)
Address Assignments
B–1
B.2 KA675/KA680/KA690 Detailed Local Address
Space Map
Local Memory Space (up to 512MB)
0000 0000 - 1FFF FFFF
Q22-bus Map - top 32KB of Main Memory
VAX I/O Space
------------Local Q22-bus I/O Space
Reserved Q22-bus I/O Space
Q22-bus Floating Address Space
User Reserved Q22-bus I/O Space
Reserved Q22-bus I/O Space
Interprocessor Comm Reg
Reserved Q22-bus I/O Space
2000
2000
2000
2000
2000
2000
2000
Local Register I/O Space
2000 2000 - 2003 FFFF
Reserved Local
SHAC1 SSWCR
Reserved Local
SHAC1 SSHMA
SHAC1 PQBBR
SHAC1 PSR
SHAC1 PESR
SHAC1 PFAR
SHAC1 PPR
SHAC1 PMCSR
Reserved Local
SHAC1 PCQ0CR
SHAC1 PCQ1CR
SHAC1 PCQ2CR
SHAC1 PCQ3CR
SHAC1 PDFQCR
SHAC1 PMFQCR
SHAC1 PSRCR
SHAC1 PECR
SHAC1 PDCR
SHAC1 PICR
SHAC1 PMTCR
SHAC1 PMTECR
Reserved Local
Register I/O Space
Register I/O Space
Register I/O Space
Register I/O Space
B–2 KA675/KA680/KA690 CPU
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
0000
0000
0008
0800
1000
1F40
1F44
4000
4030
4034
4044
4048
404C
4050
4054
4058
405C
4060
4080
4084
4088
408C
4090
4094
4098
409C
40A0
40A4
40A8
40AC
40B0
-
2000
2000
2000
2000
2000
1FFF
0007
07FF
0FFF
1F3F
- 2000 1FFF
- 2000 402F
- 2000 4043
- 2000 407F
- 2000 422F
KA675/KA680/KA690 DETAILED LOCAL ADDRESS SPACE MAP (Cont.)
SHAC2 SSWCR
Reserved Local Register I/O Space
SHAC2 SSHMA
SHAC2 PQBBR
SHAC2 PSR
SHAC2 PESR
SHAC2 PFAR
SHAC2 PPR
SHAC2 PMCSR
Reserved Local Register I/O Space
SHAC2 PCQ0CR
SHAC2 PCQ1CR
SHAC2 PCQ2CR
SHAC2 PCQ3CR
SHAC2 PDFQCR
SHAC2 PMFQCR
SHAC2 PSRCR
SHAC2 PECR
SHAC2 PDCR
SHAC2 PICR
SHAC2 PMTCR
SHAC2 PMTECR
Reserved Local Register I/O Space
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
4230
4234 - 2000 4243
4244
4248
424C
4250
4254
4258
425C
4260 - 2000 427F
4280
4284
4288
428C
4290
4294
4298
429C
42A0
42A4
42A8
42AC
42B0 - 2000 7FFF
NICSR0 NICSR1 NICSR2 NICSR3 NICSR4 NICSR5 NICSR6 NICSR7 NICSR8 NICSR9 NICSR10NICSR11NICSR12NICSR13NICSR14NICSR15Reserved
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
8000
8004
8008
800C
8010
8014
8018
801C
8020*
8024*
8028*
802C*
8030*
8034*
8038*
803C
8040 - 2003 FFFF
Vector Add, IPL, Sync/Async
Polling Demand Register
Reserved
Receiver List Address
Transmitter List Address
Status Register
Command and Mode Register
System Base Address
Reserved
Watchdog Timers
Reserved
Rev Num & Missed Frame Count
Reserved
Breakpoint Address
Reserved
Diagnostic Mode & Status
Local Register I/O Space
Address Assignments
B–3
Q-22 Bus Local Register I/O Space
DMA System Configuration Register
DMA System Error Register
DMA Master Error Address Register
DMA Slave Error Address Register
Q22-bus Map Base Register
Reserved Local Register I/O Space
Error Status Register
Memory Error Address
I/O Error Address
DMA Memory Error Address
Reg
Reg
Reg
Reg
2008 0000 - 201F FFFF
(SCR) 2008 0000
(DSER) 2008 0004
(QBEAR)2008 0008
(DEAR) 2008 000C
(QBMBR)2008 0010
2008 0014 - 2008 00FF
32
33
34
35
2008
2008
2008
2008
0180
0184
0188
018C
DMA Mode Control and
Diagnostic Status Register Reg 36
2008 0190
Reserved Local Register I/O Space
2008 0194 - 2008 3FFF
Boot and Diagnostic Reg (32 Copies)
Reserved Local Register I/O Space
B–4 KA675/KA680/KA690 CPU
(BDR)2008 4000 - 2008 407C
2008 4080 - 2008 7FFF
KA675/KA680/KA690 DETAILED LOCAL ADDRESS SPACE MAP (Cont.)
Q22-bus Map Registers
Reserved Local Register I/O Space
2008 8000 - 2008 FFFF
2009 0000 - 2013 FFFF
SSC CSRs
SSC Base Address Register
SSC Configuration Register
CP Bus Timeout Control Register
Diagnostic LED Register
Reserved Local Register I/O Space
2014
2014
2014
2014
2014
0000
0010
0020
0030
0034 - 2014 006B
VAX IPRs implemented by NCA
Interval Clock Control Status Reg
Next Interval Count Register
Interval Count Register
2100 0060
2100 0064
2100 0068
NMC CSRs
O-bit Data Registers
2101 0000 - 2101 7FFF
Main
Main
Main
Main
Main
Main
Main
Main
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Configuration
Configuration
Configuration
Configuration
Configuration
Configuration
Configuration
Configuration
Main
Main
Main
Main
Main
Main
Main
Main
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Signature
Signature
Signature
Signature
Signature
Signature
Signature
Signature
Reg
Reg
Reg
Reg
Reg
Reg
Reg
Reg
0
1
2
3
4
5
6
7
Register
Register
Register
Register
Register
Register
Register
Register
0
1
2
3
4
5
6
7
2101
2101
2101
2101
2101
2101
2101
2101
8000
8004
8008
800C
8010
8014
8018
801C
2101
2101
2101
2101
2101
2101
2101
2101
8020
8024
8028
802C
8030
8034
8038
803C
Main Memory Error Address Register
Main Memory Error Status Register
Main Memory Mode Control and
Diagnostic Register
2101 8040
2101 8044
2101 8048
O-bit Address and Mode Register
2101 804C
Address Assignments
B–5
NCA CSRs
Error Status Register
2102 0000
Mode Control and Diagnostic Reg
2102 0004
CP1 Slave Error Address Register (CP1SEA) 2102 0008
CP2 Slave Error Address Register (CP2SEA) 2102 000C
CP1 IO Error Address Register
(CP1IOEA) 2102 0010
CP2 IO Error Address Register
(CP2IOEA) 2102 0014
NDAL Error Address Register
(NDALEA) 2102 0018
Local UVROM Space
VAX System Type Register (In ROM)
Local UVROM - (Halt Protected)
B–6 KA675/KA680/KA690 CPU
E004 0000 - E007 FFFF
E004 0004
E004 0000 - E007 FFFF
**********************************************************************
The following addresses allow those KA690 Internal Processor
Registers that are implemented in the SSC chip (External, Internal
Processor Registers) to be accessed via the local I/O page. These
addresses are documented for diagnostic purposes only and should
not be used by non-diagnostic programs.
Time Of Year Register
2014 006C
Console Storage Receiver Status
Console Storage Receiver Data
Console Storage Transmitter Status
Console Storage Transmitter Data
Console Receiver Control/Status
Console Receiver Data Buffer
Console Transmitter Control/Status
Console Transmitter Data Buffer
Reserved Local Register I/O Space
2014
2014
2014
2014
2014
2014
2014
2014
2014
I/O Bus Reset Register
Reserved Local Register I/O Space
2014 00DC
2014 00E0
Reserved Local Register I/O Space
2014 00FC - 2014 00FF
0070*
0074*
0078*
007C*
0080
0084
0088
008C
0090 - 2014 00DB
* These registers are not fully implemented, accesses yield
UNPREDICTABLE results.
**********************************************************************
Local Register I/O Space (Cont.)
Timer 0 Control Register
Timer 0 Interval Register
Timer 0 Next Interval Register
Timer 0 Interrupt Vector
Timer 1 Control Register
Timer 1 Interval Register
Timer 1 Next Interval Register
Timer 1 Interrupt Vector
Reserved Local Register I/O Space
2014
2014
2014
2014
2014
2014
2014
2014
2014
0100
0104
0108
010C
0110
0114
0118
011C
0120 - 2014 012F
BDR Address Decode Match Register
BDR Address Decode Mask Register
Reserved Local Register I/O Space
2014 0140
2014 0144
2014 0138 - 2014 03FF
Battery Backed-Up RAM
Reserved Local Register I/O Space
2014 0400 - 2014 07FF
2014 0800 - 201F FFFF
Reserved Local I/O Space
2020 0000 - 2FFF FFFF
Local Q22-bus Memory Space
3000 0000 - 303F FFFF
Reserved Local Register I/O Space
3040 0000 - 3FFF FFFF
Address Assignments
B–7
B.3 External, Internal Processor Registers
Several of the Internal Processor Registers (IPRs) on the KA690 are
implemented in the NCA or SSC chip rather than the CPU chip. These
registers are referred to as External Internal Processor Registers and are
listed below.
IPR #
=====
27
Register Name
=============
Time of Year Register
Abbrev.
======
TOY
28
29
30
31
Console
Console
Console
Console
Storage
Storage
Storage
Storage
CSRS*
CSRD*
CSTS*
CSDB*
32
33
34
35
Console
Console
Console
Console
Receiver Control/Status
Receiver Data Buffer
Transmitter Control/Status
Transmitter Data Buffer
55
I/O System Reset Register
Receiver Status
Receiver Data
Transmitter Status
Transmitter Data
RXCS
RXDB
TXCS
TXDB
IORESET
* These registers are not fully implemented, accesses yield
UNPREDICTABLE results.
B.4 Global Q22–bus Address Space Map
Q22-bus Memory Space
--------------------Q22-bus Memory Space
(Octal)
0000 0000 - 1777 7777
Q22-bus I/O Space (BBS7 Asserted)
----------------------------------Q22-bus I/O Space (Octal)
Reserved Q22-bus I/O Space
Q22-bus Floating Address Space
User Reserved Q22-bus I/O Space
Reserved Q22-bus I/O Space
Interprocessor Comm Reg
Reserved Q22-bus I/O Space
B–8 KA675/KA680/KA690 CPU
1776
1776
1776
1776
1777
1777
1777
0000
0000
0010
4000
0000
7500
7502
-
1777
1776
1776
1776
1777
7777
0007
3777
7777
7477
- 1777 7777
B.5 Processor Registers
Table B–1: Processor Registers
Number
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
Kernel Stack Pointer
KSP
0
0
RW
NVAX
1-1
Executive Stack Pointer
ESP
1
1
RW
NVAX
1-1
Supervisor Stack Pointer
SSP
2
2
RW
NVAX
1-1
User Stack Pointer
USP
3
3
RW
NVAX
1-1
Interrupt Stack Pointer
ISP
4
4
RW
NVAX
1-1
5–7
5
Reserved
3
P0 Base Register
P0BR
8
8
RW
NVAX
1-2
P0 Length Register
P0LR
9
9
RW
NVAX
1-2
P1 Base Register
P1BR
10
A
RW
NVAX
1-2
P1 Length Register
P1LR
11
B
RW
NVAX
1-2
System Base Register
SBR
12
C
RW
NVAX
1-2
System Length Register
SLR
13
D
RW
NVAX
1-2
CPU Identification
CPUID
14
E
RW
NVAX
2-1
15
F
Reserved
3
Process Control Block Base
PCBB
16
10
RW
NVAX
1-1
System Control Block Base
SCBB
17
11
RW
NVAX
1-1
Interrupt Priority Level1
IPL
18
12
RW
NVAX
1-1
AST Level1
ASTLVL
19
13
RW
NVAX
1-1
Software Interrupt Request Register
SIRR
20
14
W
NVAX
1-1
Software Interrupt Summary Register1
SISR
21
15
RW
NVAX
1-1
22–23
16
Reserved
1 Initialized
3
I/O Address
E1000014
E100003C
E1000058
on reset
Address Assignments
B–9
Table B–1 (Cont.): Processor Registers
Number
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
I/O Address
Interval Counter Control/Status
ICCS
24
18
RW
NCA
2-7
E1000060
Next Interval Count
NICR
25
19
RW
NCA
3-7
E1000064
Interval Count
ICR
26
1A
RW
NCA
3-7
E1000068
Time of Year Register
TODR
27
1B
RW
SSC
2-3
E100006C
Console Storage Receiver Status
CSRS
28
1C
RW
SSC
2-3
E1000070
Console Storage Receiver Data
CSRD
29
1D
R
SSC
2-3
E1000074
Console Storage Transmitter Status
CSTS
30
1E
RW
SSC
2-3
E1000078
Console Storage Transmitter Data
CSTD
31
1F
W
SSC
2-3
E100007C
Console Receiver Control/Status
RXCS
32
20
RW
SSC
2-3
E1000080
Console Receiver Data Buffer
RXDB
33
21
R
SSC
2-3
E1000084
Console Transmitter Control/Status
TXCS
34
22
RW
SSC
2-3
E1000088
Console Transmitter Data Buffer
TXDB
35
23
W
SSC
2-3
E100008C
Reserved
36
24
3
E1000090
Reserved
37
25
3
E1000094
38
26
Reserved
39
27
3
E100009C
Reserved
40
28
3
E10000A0
Reserved
41
29
3
E10000A4
Machine Check Error Register
MCESR
W
NVAX
2-1
Console Saved PC
SAVPC
42
2A
R
NVAX
2-1
Console Saved PSL
SAVPSL
43
2B
R
NVAX
2-1
44–54
2C
55
37
Reserved
I/O System Reset Register
IORESET
B–10 KA675/KA680/KA690 CPU
W
SSC
3
E10000B0
2-3
E10000DC
Table B–1 (Cont.): Processor Registers
Number
I/O Address
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
Memory Management Enable1 3
MAPEN
56
38
RW
NVAX
1-2
Translation Buffer Invalidate All3
TBIA
57
39
W
NVAX
1-1
Translation Buffer Invalidate Single3
TBIS
58
3A
W
NVAX
1-1
Reserved
59
3B
3
E10000EC
Reserved
60
3C
3
E10000F0
System Identification
SID
62
3E
R
NVAX
1-1
Translation Buffer Check
TBCHK
63
3F
W
NVAX
1-1
IPL 14 Interrupt ACK5
IAK14
64
40
R
SSC
2-3
E1000100
IPL 15 Interrupt ACK5
IAK15
65
41
R
SSC
2-3
E1000104
IPL 16 Interrupt ACK5
IAK16
66
42
R
SSC
2-3
E1000108
IPL 17 Interrupt ACK5
IAK17
67
43
R
SSC
2-3
E100010C
Clear Write Buffer5
CWB
68
44
RW
SSC
2-3
E1000110
Reserved
69–99
45
3
E1000114
Reserved for VM
100
64
3
E1000190
Reserved for VM
101
65
3
E1000194
Reserved for VM
102
66
3
E1000198
Reserved
103–121
67
3
E100019C
Interrupt Syste Status Register
INTSYS
122
7A
RW
NVAX
2-1
Ferformance Monitoring Facility Count
PMFCNT
123
7B
RW
NVAX
2-1
Patchable Control Store Control Register
PCSCR
124
7C
WO
NVAX
2-1
Ebox Control Register
ECR
125
7D
RW
NVAX
2-1
Mbox TB Tag Fill5
MTBTAG
126
7E
W
NVAX
2-1
1 Initialized
on reset
broadcast to vector unit if present
5 Testability and diagnostic use only; not for software use in normal operation
3 Change
Address Assignments
B–11
Table B–1 (Cont.): Processor Registers
Number
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
Mbox TB PTE Fill5
MTBPTE
127
7F
W
NVAX
2-1
Cbox Control Register
CCTL
160
A0
RW
NVAX
2-5
161
A1
NVAX
2-6
Reserved
Bcache Data ECC
BCDECC
162
A2
W
NVAX
2-5
Bcache Error Tag Status
BCETSTS
163
A3
RW
NVAX
2-5
Bcache Error Tag Index
BCETIDX
164
A4
R
NVAX
2-5
Bcache Error Tag
BCETAG
165
A5
R
NVAX
2-5
Bcache Error Data Status
BCEDSTS
166
A6
RW
NVAX
2-5
Bcache Error Data Index
BCEDIDX
167
A7
R
NVAX
2-5
Bcache Error ECC
BCEDECC
168
A8
R
NVAX
2-5
Reserved
169
A9
NVAX
2-6
Reserved
170
AA
NVAX
2-6
Fill Error Address
CEFADR
171
AB
R
NVAX
2-5
Fill Error Status
CEFSTS
172
AC
RW
NVAX
2-5
173
AD
NVAX
2-6
174
AE
NVAX
2-5
175
AF
NVAX
2-6
176
B0
NVAX
2-5
177
B1
NVAX
2-6
178
B2
NVAX
2-5
179
B3
NVAX
2-6
180
B4
NVAX
2-5
Reserved
NDAL Error Status
NESTS
Reserved
NDAL Error Output Address
NEOADR
Reserved
NDAL Error Output Command
NEOCMD
Reserved
NDAL Error Data High
5 Testability
NEDATHI
RW
R
R
R
and diagnostic use only; not for software use in normal operation
B–12 KA675/KA680/KA690 CPU
I/O Address
Table B–1 (Cont.): Processor Registers
Number
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
Reserved
NDAL Error Data Low
NEDATLO
Reserved
NDAL Error Input Command
NEICMD
Reserved
181
B5
182
B6
183
B7
184
B8
185–207
B9
R
R
NVAX
2-6
NVAX
2-5
NVAX
2-6
NVAX
2-5
NVAX
2-6
VIC Memory Address Register
VMAR
208
D0
RW
NVAX
2-5
VIC Tag Register
VTAG
209
D1
RW
NVAX
2-5
VIC Data Register
VDATA
210
D2
RW
NVAX
2-5
Ibox Control and Status Register
ICSR
211
D3
RW
NVAX
2-5
Ibox Branch Prediction Control Register5
BPCR
212
D4
RW
NVAX
2-5
213
D5
NVAX
2-6
Reserved
Ibox Backup PC5
BPC
214
D6
R
NVAX
2-5
Ibox Backup PC with RLOG Unwind5
BPCUNW
215
D7
R
NVAX
2-5
216–223
D8
NVAX
2-6
Reserved
Mbox P0 Base Register5
MP0BR
224
E0
RW
NVAX
2-5
Mbox P0 Length Register5
MP0LR
225
E1
RW
NVAX
2-5
Mbox P1 Base Register5
MP1BR
226
E2
RW
NVAX
2-5
Mbox P1 Length Register5
MP1LR
227
E3
RW
NVAX
2-5
Mbox System Base Register5
MSBR
228
E4
RW
NVAX
2-5
Mbox System Length Register5
MSLR
229
E5
RW
NVAX
2-5
Mbox Memory Management Enable5
MMAPEN
230
E6
RW
NVAX
2-5
Mbox Physical Address Mode
PAMODE
231
E7
RW
NVAX
2-5
Mbox MME Address
MMEADR
232
E8
R
NVAX
2-5
5 Testability
I/O Address
and diagnostic use only; not for software use in normal operation
Address Assignments
B–13
Table B–1 (Cont.): Processor Registers
Number
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
Mbox MME PTE Address
MMEPTE
233
E9
R
NVAX
2-5
Mbox MME Status
MMESTS
234
EA
R
NVAX
2-5
235
EB
NVAX
2-6
Reserved
Mbox TB Parity Address
TBADR
236
EC
R
NVAX
2-5
Mbox TB Parity Status
TBSTS
237
ED
RW
NVAX
2-5
Reserved
238
EE
NVAX
2-6
Reserved
239
EF
NVAX
2-6
Reserved
240
F0
NVAX
2-6
Reserved
241
F1
NVAX
2-6
242
F2
NVAX
2-5
243
F3
NVAX
2-6
241
F4
NVAX
2-5
Reserved
245
F5
NVAX
2-6
Reserved
246
F6
NVAX
2-6
Reserved
247
F7
NVAX
2-6
248
F8
NVAX
2-5
Reserved
249
F9
NVAX
2-6
Reserved
250
FA
NVAX
2-6
Reserved
251
FB
NVAX
2-6
Reserved
252
FC
NVAX
2-6
Reserved
253
FD
NVAX
2-6
Reserved
254
FE
NVAX
2-6
Reserved
255
FF
NVAX
2-6
Mbox Pcache Parity Address
PCADR
Reserved
Mbox Pcache Status
Mbox Pcache Control
PCSTS
PCCTL
B–14 KA675/KA680/KA690 CPU
R
RW
RW
I/O Address
Table B–1 (Cont.): Processor Registers
Number
Register Name
Mnemonic(Dec) (Hex) Type Impl Cat
Unimplemented
100–
00FFFFFF
3
See Table B–2
01000000–
2
I/O Address
FFFFFFFF
Type:
R = Read-only register
RW = Read-write register
W = Write-only register
Impl(emented):
NVAX = Implemented in the NVAX CPU chip
System = Implemented in the system environment
Vector = Implemented in the optional vector unit or its NDAL interface
Cat(egory), class-subclass, where:
class is one of:
1 = Implemented as per DEC standard 032
2 = NVAX-specific implementation which is unique or different from the DEC standard 032
implementation
3 = Not implemented internally; converted to I/O space read or write and passed to system
environment
subclass is one of:
1 = Processed as appropriate by Ebox microcode
2 = Converted to Mbox IPR number and processed via internal IPR command
3 = Processed by internal IPR command, then converted to I/O space read or write and
passed to system environment
4 = If virtual machine option is implemented, processed as in 1, otherwise as in 3
5 = Processed by internal IPR command
6 = May be block decoded; reference causes UNDEFINED behavior
7 = Full interval timer may be implemented in the system environment. Subset ICCS is
implemented in NVAX CPU chip
8 = Converted to MFVP MSYNC
Address Assignments
B–15
B.6 IPR Address Space Decoding
Table B–2: IPR Address Space Decoding
IPR Address Range
Mnemonic2 (hex)
Contents
IPR Group
00000000..000000FF1 256 individual IPRs.
Normal
Bcache Tag
BCTAG
01000000..011FFFE01 64k Bcache tag IPRs, each separated by 20(hex) from the previous
one.
Bcache Deallocate
BCFLUSH
01400000..015FFFE01 64k Bcache tag deallocate IPRs,
each separated by 20(hex) from
the previous one.
Pcache Tag
PCTAG
01800000..01801FE01 256 Pcache tag IPRs, 128 for each
Pcache set, each separated by
20(hex) from the previous one.
Pcache Data Parity
PCDAP
01C00000..01C01FF81 1024 Pcache data parity IPRs,
512 for each Pcache set, each
separated by 8(hex) from the
previous one.
1 Unused
fields in the IPR addresses for these groups should be zero. Neither hardware nor
microcode detects and faults on an address in which these bits are non-zero. Although noncontiguous address ranges are shown for these groups, the entire IPR address space maps into
one of these groups. If these fields are non-zero, the operation of the CPU is UNDEFINED.
2 The mnemonic is for the first IPR in the block
Processor registers in all groups except the normal group are processed
entirely by the NVAX CPU chip and will never appear on the NDAL. This
is also true for a number of the IPRs in the normal group. IPRs in the
normal group that are not processed by the NVAX CPU chip are converted
into I/O space references and passed to the system environment via a read
or write command on the NDAL.
Each of the 256 possible IPRs in the normal group are of longword length,
so a 1KB block of I/O space is required to convert each possible IPR to a
unique I/O space longword. This block starts at address E1000000 (hex).
Conversion of an IPR address to an I/O space address in this block is done
by shifting the IPR address left into bits <9:2>, filling bits <1:0> with zeros,
and merging in the base address of the block. This can be expressed by the
equation
"!$#%'&)(*
B–16 KA675/KA680/KA690 CPU
Appendix C
ROM Partitioning
This section describes ROM partitioning and subroutine entry points that
are public and are guaranteed to be compatible over future versions of
the firmware. An entry point is the address at which any subroutine or
subprogram will start execution .
C.1 Firmware EPROM Layout
The KA675/KA680/KA690 has 512 Kbytes of FEPROM. Unlike previous
Q22–bus based processors, there is no duplicate decoding of the FEPROM
into halt-protected and halt-unprotected spaces. The entire FEPROM is
halt-protected.
ROM Partitioning
C–1
Figure C–1: KA675/KA680/KA690 FEPROM Layout
20040000
Branch Instruction
20040006
System ID Extension
20040008
PC$MSG_OUT_NOLF_R4
2004000C
CP$READ_WITH_PRMPT_R4
20040010
Rsvd Mfg L200 Testing
20040014
Def Boot Dev Dscr Ptr
2004001c
Def Boot Flags Ptr
Console, Diagnostic,
and Boot Code
EPROM Checksum
Reserved for Digital
2005F800
4 Pages Reserved
for Customer Use
2005FFFC
MLO-007698
The first instruction executed on halts is a branch around the System Id
Extension (SIE) and the callback entry points. This allows these public
data structures to reside in fixed locations in the FEPROM.
The callback area entry points provide a simple interface to the currently
defined console for VMB and secondary bootstraps. This is documented
further in the next section.
The fixed area checksum is the sum of longwords from 20040000 to the
checksum inclusive. This checksum is distinct from the checksum that the
rest of the console uses.
The console, diagnostic and boot code constitute the bulk of the firmware.
This code is field upgradable. The console checksum is from 20044000 to
the checksum inclusive.
The memory between the console checksum and the user area at the end of
the FEPROM is reserved for Digital for future expansion of the firmware.
The contents of this area is set to FF.
C–2 KA675/KA680/KA690 CPU
The last 4096 bytes of FEPROM is reserved for customer use and is not
included in the console checksum. During a PROM bootstrap with PRB0
as the selected boot device, this block is the tested for a PROM "signature
block".
C.1.1 System Identification Registers
The firmware and operating system software reference two registers to
determine the processor on which they are running. The first, the System
Identification register (SID), is a NVAX internal processor register. The
second, the System Identification Extension register (SIE), is a firmware
register located in the FEPROM.
C.1.1.1 PR$_SID (IPR 62)
The SID longword can be read from IPR 62 using the MFPR instruction.
This longword value is processor specific, however, the layout of this register
is shown in Figure C–2. A desciption of each field is provided in Table C–1.
Figure C–2: SID : System Identification Register
24 23
31
CPU_TYPE
08 07
Reserved
00
Version
MLO-007699
Table C–1: System Identification Register
Field
Name
RW Description
31:24
CPU_TYPE
ro
CPU type is the processor specific identification code.
0A : CVAX
0B : RIGEL
13 : NVAX
14 : SOC
24:8
reserved
ro
Reserved for future use.
7:0
VERSION
ro
Version of the microcode.
ROM Partitioning
C–3
C.1.1.2 SIE (20040004)
The System Identification Extension register is an extention to the SID and
is used to further differentiate between hardware configurations. The SID
identifies which CPU and microcode is executing, and the SIE identifies
what module and firmware revision are present. Note, the fields in this
register are dependent on SID<31:24>(CPU_TYPE).
By convention, all VAX 4000 systems implement a longword at physical
location 20040004 in the firmware FEPROM for the SIE. The layout of
the SIE is shown in Figure C–3. A description of each field is provided in
Table C–2.
Figure C–3: SIE : System Identification Extension (20040004)
24 23
31
08 07
16 15
Version
SYS_TYPE
SYS_SUB_TYPE
00
Variant
MLO-007700
Table C–2: System Identification Extension
Field
Name
RW Description
31:24
SYS_TYPE
ro
This field identifies the type of system for a specific processor.
01 : Q22–bus single processor system.
23:16
VERSION
ro
This field indentifies the resident version of the firmware
encoded as two hexadecimal digits. For example, if the
banner displays V5.0, then this field is 50 (hex).
15:8
SYS_SUB_TYPE
ro
This field indentifies the particular system subtype.
01 :
02 :
03 :
04 :
05 :
12 :
06 :
07 :
7:0
VARIANT
ro
KA650
KA640
KA655
KA670
KA660
KA675
KA680
KA690
This field indentifies the particular system variant.
C–4 KA675/KA680/KA690 CPU
C.1.2 Call-Back Entry Points
The firmware provides several entry points that facilitate I/O to the
designated console device. Users of these entry points do not need to be
aware of the console device type, be it a video terminal or workstation.
The primary intent of these routines is to provide a simple console device
to VMB and secondary bootstraps, before operating systems load their own
terminal drivers.
These are JSB (subroutine as opposed to procedure) entry points located in
fixed locations in the firwmare. These locations branch to code that in turn
calls the appropriate routines.
All of the entry points are designed to run at IPL 31 on the interrupt stack
in physcial mode. Virtual mode is not supported. Due to internal firmware
architectural restrictions, users are encouraged to only call into the haltprotected entry points. These entry points are listed in Table C–3.
Table C–3: Call-Back Entry Points
CP$GET_CHAR_R4
20040008
CP$MSG_OUT_NOLF_R4
2004000C
CP$READ_WTH_PRMPT_ 20040010
R4
C.1.2.1 CP$GETCHAR_R4
This routine returns the next character entered by the operator in R0. A
timeout interval can be specified. If the timeout interval is zero, no timeout
is generated. If a timeout is specified and if timeout occurs, a value of 18
(CAN) is returned instead of normal input.
Registers R0,R1,R2,R3 and R4 are modified by this routine, all others are
preserved.
;--------------------------------------------------------------; Usage with timeout:
movl
jsb
cmpb
beql
; Input
#timeout_in_tenths_of_second,r0
@#CP$GET_CHAR_R4
r0,#^x18
timeout_handler
is in R0.
;
;
;
;
Specify timeout.
Call routine.
Check for timeout.
Branch if timeout.
;--------------------------------------------------------------; Usage without timeout:
ROM Partitioning
C–5
clrl
r0
jsb
@#CP$GET_CHAR_R4
; Input is in R0.
; Specify no timeout.
; Call routine.
;---------------------------------------------------------------
C.1.2.2 CP$MSG_OUT_NOLF_R4
This routine outputs a message to the console. The message is specified
either by a message code or a string descriptor. The routine distinguishes
between message codes and descriptors by requiring that any descriptor
be located outside of the first page of memory. Hence, message codes are
restricted to values between 0 and 511.
Registers R0,R1,R2,R3 and R4 are modified by this routine, all others are
preserved.
;--------------------------------------------------------------; Usage with message code:
movzbl
jsb
#console_message_code,r0
@#CP$MSG_OUT_NOLF_R4
; Specify message code.
; Call routine.
;--------------------------------------------------------------; Usage with a message descriptor (position dependent).
movaq
jsb
.
.
5$,r0
@#CP$MSG_OUT_NOLF_R4
; Specify address of desc.
; Call routine.
5$:
.ascid
; Message with descriptor.
/This is a message/
;--------------------------------------------------------------; Usage with a message descriptor (position independent).
pushab
pushl
movl
jsb
clrq
.
.
5$
#10$-5$
sp,r0
@#CP$MSG_OUT_NOLF_R4
(sp)+
;
;
;
;
;
5$:
10$:
.ascii
; Message.
;
/This is a message/
Generate message desc.
on stack.
Pass desc. addr. in R0.
Call routine.
Purge desc. from stack.
;---------------------------------------------------------------
C–6 KA675/KA680/KA690 CPU
C.1.2.3 CP$READ_WTH_PRMPT_R4
This routine outputs a prompt message and then inputs a character string
from the console. When the input is accepted, DELETE, CONTROL-U and
CONTROL-R functions are supported.
As with CP$MSG_OUT_NOLF_R4, either a message code or the address of
a string descriptor is passed in R0 to specify the prompt string. A value of
zero results in no prompt. A time-out value in 10-millisecond ticks may be
passed in R1. If R1 is zero, the prompt will not timeout.
A descriptor of the input string is returned in R0 and R1. R0 contains the
length of the string and R1 contains the address. This routine inputs the
string into the console program string buffer and therefore the caller need
not provide an input buffer. Successive calls however destroy the previous
contents of the input buffer.
Registers R0,R1 are modified by this routine, all others are preserved.
;--------------------------------------------------------------; Usage with a message descriptor (position independent).
pushab
pushl
movl
clrl
jsb
clrq
.
.
5$
#10$-5$
sp,r0
r1
@#CP$READ_WTH_PRMPT_R4
(sp)+
;
;
;
;
;
;
;
5$:
10$:
.ascii
; Prompt string.
/Prompt> /
Generate prompt desc.
on stack.
Pass desc. addr. in R0.
Specify no time-out.
Call routine.
Purge prompt desc.
Input desc in R0 and R1.
;---------------------------------------------------------------
C.1.3 Boot Information Pointers
Two longwords located in FEPROM are used as pointers to the default boot
device descriptor and the default boot flags, because the actual location of
this data may change in successive versions of the firmware. Any software
that uses these pointers should reference them at the addresses in haltprotected space.
ROM Partitioning
C–7
Figure C–4: Boot Information Pointers
20040018
Def Boot Dev Dscr Ptr
Class
Type
Desc Length
Boot Device String Ptr
2004001c
Def Boot Flags Ptr
ASCIZ Dev Name String
Boot Flags (Longword)
MLO-007701
The following macro defines the boot device descriptor format.
;------------------------------------------------------------; Default Boot Device Descriptor
;
boot_device_descriptor::
base = .
. = base + dsc$w_length
.word
nvr$s_boot_device
. = base + dsc$b_dtype
.byte
dsc$k_dtype_z
. = base + dsc$b_class
.byte
dsc$k_class_z
. = base + dsc$a_pointer
.long
nvr_base + nvr$b_boot_device
. = base + dsc$s_dscdef1
;-------------------------------------------------------------
C–8 KA675/KA680/KA690 CPU
Appendix D
Data Structures and Memory Layout
This appendix contains definitions of the key global data structures used
by the CPU firmware.
D.1 Halt Dispatch State Machine
The CPU halt dispatcher determines what actions the firmware will take on
halt entry based on the machine state. The dispatcher is implemented as a
state machine, which uses a single bitmap control word and the transition
(see Table D–1) to process all halts. The transition table is sequentially
searched for matches with the current state and control word. If there is a
match, a transition occurs to the next state.
The control word comprises the following information.
•
Halt Type, used for resolving external halts. Valid only if Halt Code
is 00.
000 :
001 :
010 :
011 :
100 :
101 :
•
Halt Code, compressed form of SAVPSL<13:8>(RESTART_CODE).
00 :
01 :
10 :
11 :
•
power-up state
halt in progress
negation of Q22–bus DCOK
console BREAK condition detected
Q22–bus BHALT
SGEC BOOT_L asserted (trigger boot)
RESTART_CODE = 2, external halt
RESTART_CODE = 3, power-up/reset
RESTART_CODE = 6, halt instruction
RESTART_CODE = any other, error halts
Mailbox Action, passed by an operating system in CPMBX<1:0>(HALT_
ACTION).
00 :
01 :
10 :
11 :
restart, boot, halt
restart, halt
boot, halt
halt
Data Structures and Memory Layout
D–1
•
User Action, specified with the SET HALT console command.
000 :
001 :
010 :
011 :
100 :
default
restart, halt
boot, halt
halt
restart, boot, halt
•
HEN, Break (halt) Enable/Disable switch, BDR<07>
•
ERR, error status
•
TIP, trace in progress
•
DIP, diagnostics in progress
•
BIP, bootstrap in progress CPMBX<2>
•
RIP, restart in progress CPMBX<3>
A transition to a "next state" occurs if a match is found between the control
word and a "current state" entry in the table. The firmware does a linear
search through the table for a match. Therefore, the order of the entries
in the transition table is important. The control longword is reassembled
before each transition from the current machine state. The state machine
transitions are shown in Table D–1.
Table D–1: Firmware State Transition Table
Current
State
Next
State
Halt
Type
Halt
Code
Mailbx
User
HEN-ERR-TIP-DIPAction Action BIP-RIP
Perform conditional initialization.
1
ENTRY
–>RESET INIT
xxx
01
xx
xxx
x-x-x-x-x-x
ENTRY
–>BREAK INIT
011
00
xx
xxx
x-x-x-x-x-x
ENTRY
–>TRACE INIT
xxx
10
xx
xxx
x-0-1-x-x-x
ENTRY
–>OTHER INIT
xxx
xx
xx
xxx
x-x-x-x-x-x
Perform common initialization.
RESET INIT
–>INIT
xxx
xx
xx
2
xxx
x-x-x-x-x-x
1 Perform a unique initialization routine on entry. In particular, power-ups, BREAKs, and
TRACEs require special initialization. Any other halt entry performs a default initialization.
2 After performing conditional initialization, complete common initialization.
D–2 KA675/KA680/KA690 CPU
Table D–1 (Cont.): Firmware State Transition Table
Mailbx
Current
State
Next
State
Halt
Type
Halt
Code
User
HEN-ERR-TIP-DIPAction Action BIP-RIP
BREAK INIT
–>INIT
xxx
xx
xx
xxx
x-x-x-x-x-x
TRACE INIT
–>INIT
xxx
xx
xx
xxx
x-x-x-x-x-x
OTHER INIT
–>INIT
xxx
xx
xx
xxx
x-x-x-x-x-x
Check for external halts.
3
INIT
–>BOOTSTRAP
010
00
xx
xxx
0-x-x-x-x-x
INIT
–>BOOTSTRAP
101
00
xx
xxx
x-x-x-x-x-x
INIT
–>HALT
xxx
00
xx
xxx
x-x-x-x-x-x
Check for pending (NEXT) trace.
4
INIT
–>TRACE
xxx
10
xx
xxx
x-x-1-x-x-x
TRACE
–>EXIT
xxx
10
xx
xxx
x-0-1-x-x-x
TRACE
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
Check for bootstrap conditions.
5
INIT
–>BOOTSTRAP
xxx
01
xx
xxx
0-0-0-0-0-0
INIT
–>BOOTSTRAP
xxx
01
xx
010
1-0-0-0-0-0
INIT
–>BOOTSTRAP
xxx
01
xx
100
1-0-0-0-0-0
INIT
–>BOOTSTRAP
xxx
1x
10
xxx
x-0-0-0-0-0
3
Halt on all external halts, except:
if DCOK (unlikely) and halts are disabled, bootstrap
if SGEC remote trigger, bootstrap
4 Unconditionally enter the TRACE state, if the TIP flag is set and the halt was due to a
HALT instruction. From the TRACE state the firmware exits, if TIP is set and ERR is clear;
otherwise it halts.
5 Bootstrap,
if
if
if
if
if
power-up and halts are disabled.
power-up and halts are enabled and user action is 2 or 4.
not power-up and mailbox is 2.
not power-up and mailbox is 0 and user action is 2.
not power-up and restart failed and mailbox is 0 and user action is 0 or 4.
Data Structures and Memory Layout
D–3
Table D–1 (Cont.): Firmware State Transition Table
Mailbx
Current
State
Next
State
Halt
Type
Halt
Code
User
HEN-ERR-TIP-DIPAction Action BIP-RIP
INIT
–>BOOTSTRAP
xxx
1x
00
010
x-0-0-0-0-0
INIT
–>BOOTSTRAP
xxx
1x
00
100
x-0-0-0-0-1
INIT
–>BOOTSTRAP
xxx
1x
00
100
x-1-0-0-0-x
INIT
–>BOOTSTRAP
xxx
1x
00
000
0-0-0-0-0-1
RESTART
–>BOOTSTRAP
xxx
1x
00
000
0-1-0-0-0-x
Check for restart conditions.
6
INIT
–>RESTART
xxx
1x
01
xxx
x-0-0-0-0-0
INIT
–>RESTART
xxx
1x
00
001
x-0-0-0-0-0
INIT
–>RESTART
xxx
1x
00
100
x-0-0-0-0-0
INIT
–>RESTART
xxx
1x
00
000
0-0-0-0-0-0
Perform common exit processing, if
no errors. 7
BOOTSTRAP
–>EXIT
xxx
xx
xx
xxx
x-0-x-x-x-x
RESTART
–>EXIT
xxx
xx
xx
xxx
x-0-x-x-x-x
HALT
–>EXIT
xxx
xx
xx
xxx
Exception transitions, just halt.
x-0-x-x-x-x
8
INIT
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
BOOT
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
REST
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
HALT
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
6
Restart the operating system if not power-up and,
if mailbox is 1.
if mailbox is 0 and user action is 1 or 4.
if mailbox is 0 and user action is 0 and halts are disabled.
7
8
Exit after halts, bootstrap or restart. The exit state transitions to program I/O mode.
Guard block that catches all exception conditions. In all cases, just halt.
D–4 KA675/KA680/KA690 CPU
Table D–1 (Cont.): Firmware State Transition Table
Mailbx
Current
State
Next
State
Halt
Type
Halt
Code
User
HEN-ERR-TIP-DIPAction Action BIP-RIP
TRACE
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
EXIT
–>HALT
xxx
xx
xx
xxx
x-x-x-x-x-x
"x" is used in this table to indicate a "don’t care" field.
Data Structures and Memory Layout
D–5
D.2 RPB
VMB typically utilizes the low portion of memory unless there are bad
pages in the first 128Kbytes. The first page in its block is used for the RPB
(Restart Parameter Block), through which it communicates to the operating
system. Usually, this is page 0.
VMB will initialize the Restart Parameter Block (RPB) as shown in
Table D–2.
Table D–2: Restart Parameter Block fields
(R11)+Field Name
Description
00:
RPB$L_BASE
Physical address of base of RPB.
04:
RPB$L_RESTART
Cleared.
08:
RPB$L_CHKSUM
-1
0C:
RPB$L_RSTRTFLG
Cleared.
10:
RPB$L_HALTPC
R10 on entry to VMB (HALT PC).
10:
RPB$L_HALTPSL
PR$_SAVPSL on entry to VMB (HALT PSL).
18:
RPB$L_HALTCODE
AP on entry to VMB (HALT CODE).
1C:
RPB$L_BOOTR0
R0 on entry to VMB.
NOTE: The field RPB$W_R0UBVEC, which
overlaps the high-order word of RPB$L_
BOOTR0, is set by the boot device drivers to
the SCB offset (in the second page of the SCB)
of the interrupt vector for the boot device.
20:
RPB$L_BOOTR1
VMB version number. The high-order word of the version
is the major ID and the low-order word is the minor ID.
24:
RPB$L_BOOTR2
R2 on entry to VMB.
28:
RPB$L_BOOTR3
R3 on entry to VMB.
D–6 KA675/KA680/KA690 CPU
Table D–2 (Cont.): Restart Parameter Block fields
(R11)+Field Name
Description
2C:
R4 on entry to VMB.
RPB$L_BOOTR4
NOTE: The 48-bit booting node address is
stored in RPB$L_BOOTR3 and RPB$L_
BOOTR4 for compatibility with ELN V1.1
(this field is only initialized this way when
performing a network boot).
30:
RPB$L_BOOTR5
R5 on entry to VMB.
34:
RPB$L_IOVEC
Physical address of boot driver’s I/O vector of transfer
addresses.
38:
RPB$L_IOVECSZ
Size of BOOT QIO routine.
3C:
RPB$L_FILLBN
LBN of secondary bootstrap image.
40:
RPB$L_FILSIZ
Size of secondary bootstrap image in blocks.
44:
RPB$Q_PFNMAP
The PFN bitmap is a array of bits, where each bit has
the value "1" if the corresponding page of memory is
valid, or has the value "0" if the corresponding page
of memory contains a memory error. Through use of
the PFNMAP, the operating system can avoid memory
errors by avoiding known bad pages altogether. The
memory bitmap is always page-aligned, and describes all
the pages of memory from physical page #0 to the high
end of memory, but excluding the PFN bitmap itself and
the Q–bus map registers. If the high byte of the bitmap
spans some pages available to the operating system
and some pages of the PFN bitmap itself, the pages
corresponding to the bitmap itself will be marked as bad
pages. The first longword of the PFNMAP descriptor
contains the number of bytes in the PFNMAP; the second
longword contains the physical address of the bitmap.
4C:
RPB$L_PFNCNT
Count of "good" pages of physical memory, but not
including the pages allocated to the Q22–bus scatter
/gather map, the console scratch area, and the PFN
bitmap at the top of memory.
50:
RPB$L_SVASPT
0.
54:
RPB$L_CSRPHY
Physical address of CSR for boot device.
Data Structures and Memory Layout
D–7
Table D–2 (Cont.): Restart Parameter Block fields
(R11)+Field Name
Description
58:
RPB$L_CSRVIR
0.
5C:
RPB$L_ADPPHY
Physical address of ADP. (really the address of QMRs ^x800 to look like a UBA adapter).
60:
RPB$L_ADPVIR
0.
64:
RPB$W_UNIT
Unit number of boot device.
66:
RPB$B_DEVTYP
Device type code of boot device.
67:
RPB$B_SLAVE
Slave number of boot device.
68:
RPB$T_FILE
Name of secondary bootstrap image (defaults to
[SYS0.SYSEXE]SYSBOOT.EXE). This field (up to 40
bytes) is overwritten with the input string on a ‘‘solicit’’
boot.
NOTE: 1 : For VAX/VMS, the RPB$T_FILE
must contain the root directory string "SYSn."
on a non-network bootstrap. This string is
parsed by SYSBOOT (SYSBOOT does not
use the high nibble of BOOTR5). 2 : The
RPB$T_FILE is overwritten to contain the
boot node name for compatibility with ELN
V1.1 (this field is only initialized this way
when performing a network boot).
90:
RPB$B_CONFREG
Array (16 bytes) of adapter types (NDT$_UB0 - UNIBUS
).
A0:
RPB$B_HDRPGCNT
Count of header pages.
A1:
RPB$W_BOOTNDT
Boot adapter nexus device type. Used by SYSBOOT
and INIADP (OF SYSLOA) to configure the adapter of
the boot device (changed from a byte to a word field in
Version 12 of VMB).
B0:
RPB$L_SCBB
Physical address of SCB.
BC:
RPB$L_MEMDSC
Count of pages in physical memory including both good
and bad pages. The high 8 bits of this longword contain
the TR #, which is always 0 for KA675/KA680/KA690.
)
D–8 KA675/KA680/KA690 CPU
Table D–2 (Cont.): Restart Parameter Block fields
(R11)+Field Name
Description
C0:
PFN of the first page of memory. This field is always 0
for KA675/KA680/KA690, even if page #0 is a bad page.
RPB$L_MEMDSC+4
NOTE: No other memory descriptors are
used.
104:
RPB$L_BADPGS
Count of "bad" pages of physical memory.
108:
RPB$B_CTRLLTR
Boot device controller number biased by 1. In VAX/VMS,
this field is used by INIT (in SYS) to construct the boot
device’s controller letter. A 0 implies this field has not
been initialized, else if initialized, A=1, B=2, etc. (this
field was added in Version 13 of VMB).
nn:
The rest of the RPB is zeroed.
D.3 VMB Argument List
The VMB code will also initialize an argument list as shown in Table D–3
(the address of the argument list is passed in the AP):
Table D–3: VMB Argument List
(AP)+ Field Name
Description
04:
VMB$L_FILECACHE
Quadword filename.
0C:
VMB$L_LO_PFN
PFN of first page of physical memory (always 0,
regardless of where 128Kbytes of "good" memory starts).
10:
VMB$L_HI_PFN
PFN of last page of physical memory.
14:
VMB$Q_PFNMAP
Descriptor of PFN bitmap. First longword contains count
of bytes in bitmap. Second longword contains physical
address of bitmap. (Same rules as for RPB$Q_PFNMAP
listed above.)
1C:
VMB$Q_UCODE
Quadword.
Data Structures and Memory Layout
D–9
Table D–3 (Cont.): VMB Argument List
(AP)+ Field Name
Description
24:
VMB$B_SYSTEMID
48-bit (actually a quadword is allocated) booting node
address which is initialized when performing a network
boot. This field is copied from the Target System Address
parameter of the parameters message. (The DECnet
HIORD value is added if the field was two bytes.)
2C:
VMB$L_FLAGS
Set as needed.
30:
VMB$L_CI_HIPFN
Cluster interface high PFN.
34:
VMB$Q_NODENAME
Boot node name which is initialized when performing a
network boot. This field is copied from the Target System
Name parameter of the parameters message.
3C:
VMB$Q_HOSTADDR
Host node address (this value is only initialized when
booting over the network). This field is copied from
the Host System Address parameter of the parameters
message.
44:
VMB$Q_HOSTNAME
Host node name (this value is only initialized when
performing a network boot). This field is copied from
the Host System Name parameter of the parameters
message.
4C:
VMB$Q_TOD
Time of day (this value is only initialized when
performing a network boot). The time of day is copied
from the first eight bytes of the Host System Time
parameter of the parameters message.
(The time
differential values are NOT copied.)
54:
VMB$L_XPARAM
Pointer to data retrieved from request of the parameter
file.
58:
The rest of the argument list is zeroed.
.
D–10 KA675/KA680/KA690 CPU
Appendix E
Configurable Machine State
The KA675/KA680/KA690 CPU module has many control registers that
need to be configured for proper operation of the module. The following list
shows the normal state of all configurable bits in the CPU module as they
are left after the successful completion of power-up ROM diagnostics.
VAX 4000 Models 400,500,600
Configuration registers and writable bits: (* = power up reset state)
NCA:
====
CMCDSR: Mode Control and Diagnostic Status Register (2102 0004)
-------------------------------------------------------15:14: CP2 MT Timer Prescaler
11 = 144000 cycles* - needed for CQBIC 10ms No Grant
timeout
13:12: CP1 MT Timer Prescaler
00 = 144 cycles - minimum for passive releases, no
cycle should take longer than this
11:10: NDAL Timeout Prescaler
00 = 3200 cycles* - this is longer than both NCA and
NMC transactions timeouts, preserves timeout
order
9: QBUS_TRANS enable (formerly CQBIC_PRESENT)
0 = QBUS_TRANS signal disabled* - this is to avoid
QBUS_TRANS deadlock
8: IO2 ID enable
1 = enabled
7: Force wrong CP2 bus parity
0 = off* - diagnostic use only
6: Force wrong CP1 bus parity
0 = off* - diagnostic use only
5: Force wrong NDAL master parity
0 = off* - diagnostic use only
4: Force wrong NDAL slave parity
0 = off* - diagnostic use only
3: Enable prefetch
1 = enable CP bus prefetch on DMA reads
2: Force write buffer hit
0 = off* - diagnostic use only
Configurable Machine State
E–1
1: Force CP2 bus owner
0 = disabled - diagnostic use only
0: Force CP1 bus owner
0 = disabled - diagnostic use only
ICCS: Interval Clock Control and Status Register (2100 0060)
------------------------------------------------------NOTE: VMS sets ICCS, NICR to proper values
6: Interrupt enable
0 = disabled*
5: Single step
0 = off*
4: Transfer
0 = disabled*
0: Run - increment every 1µs
0 = do not increment*
NICR: Next Interval Count Register (2100 0064)
----------------------------------------31:0 Initial count value for ICR (FFFFD8F0* (10ms))
NMC:
====
MEMCON_0-7: Memory Configuration Registers (2101 8000 thru 2101 801C)
---------------------------------------------------------NOTE: Diagnostics set these registers based on available memory
31: Base Address Valid
0 = not valid*
1 = valid
28:24: Base Address (0 on reset)
1MB RAM - all address bits used
4MB RAM - only <28:26> used
2:1 RAM size
00 = 1MB RAM*
01 = 1MB RAM
10 = 4MB RAM
11 = non-existent bank
0: Mode
1 = 64-bit mode
MMCDSR: Mode Control and Diagnostic Status Register (2101 8048)
-------------------------------------------------------31: Fast Diagnostic Mode (FDM)
0 = disabled* - diagnostic use only
30: FDM Second pass
0 = disabled* - diagnostic use only
29: Diagnostic Checkbit mode
0 = disabled* - diagnostic use only
28: QBus on I01
0 = QBus on IO2*
27: Enable soft error log (NDAL & memory related)
0 = disabled* - VMS enables this
E–2 KA675/KA680/KA690 CPU
26: Flush BCache
0 = don’t flush*
24:17: Memory diagnostic check bits
0 - meaningful only in diagnostic check mode* (may or
may not be read as 0)
8:7: NDAL Timeout Scaler
00 = 2600 cycles* - maximum, to preserve timeout order
6: Disable memory error
0 = memory errors deteted and corrected*
5: Refresh interval timer select
0 = 328 cycles* (Model 500,600)
1 = 244 cycles (Model 400)
4:2: Force wrong parity on NDAL transactions
0 = off* - diagnostic use only
1: Disable memory refresh
0 = memory refreshed*
0: Force refresh
0 = normal refresh*
MOAMR: O-bit Address and Mode Register (2101 804C)
-------------------------------------------16: Ignore O-bit mode
0 = O-bits checked*
15: Disable O-bit error
0 = O-bit errors detected*
14:6: O-bit segment address (0*) - meaningful only during
O-bit data register access
5:3: O-bit mask (0*) - meaningful only during O-bit data
register access
2:0: O-bit operation mode
000 = reconstruction mode* - meaningful only during
O-bit data register access
MODR: O-bit Data Registers (2101 0000 thru 2101 7FFF)
-----------------------------------------------23:12: O-bit field 1 (0*) - used only during Fast Memory test
11:0: O-bit field 0 (0*) - used only during Fast O-bit test
mode
NVAX:
=====
CPUID: CPU ID Register (IPR E)
-----------------------7:0: CPU identifcation = 0 (for single processor config.)
SID: System Identification Register (IPR 3E)
---------------------------------------NOTE: this register may only be written by microcode
31:24: CPU type - 13hex (NVAX code)
13:8: Patch revision
Configurable Machine State
E–3
7:0: Microcode revision
ICSR: IBox Control and Status Register (IPR D3)
----------------------------------------0: VIC enable
0 = disabled* (Model 400)
1 = enabled
(Models 500,600)
ECR: EBox Control Register (IPR 7D)
------------------------------13: FBox test enable
0 = disabled* - diagnostic use only
7: Interval time mode
1 = full CPU implemented interval timer
5: S3 stall timeout
0 = counts cycles w/ timeout_enable asserted* (~3 sec)
3: FBox stage 4 bypass
1 = enabled - result from stage 3 passed directly to
FBox output interface (improves FBox latency)
2: S3 external time base timeout
0 = disabled* - use internal time base
1: FBox enable
1 = enabled
0: Vector present
0 = no* - no vector option available at this time
MMAPEN: Memory Map Enable Register (IPR E6)
-----------------------------------0: Memory map enable
0 = disabled* - VMS enables this
PAMODE: Physical Address Mode Register (IPR E7)
---------------------------------------0: Physical address mode
0 = 30-bit physical address space*
PCCTL: PCache Control Register (IPR F8)
--------------------------------8: PCache Electrical disable
0 = PCache enabled*
7:5 MBox performance monitor mode
0 - diagnostic use only*
4: PCache error enable
1 = enables PCache error detection
3: Bank select during force hit mode
0 = left bank selected if force hit mode enabled*
- diagnostic use only
2: Force hit
0 = disabled* - diagnostic use only
1: I_enable
1 = enable PCache for IREAD, INVAL, I_CF commands
E–4 KA675/KA680/KA690 CPU
0: D_enable
1 = enable PCache for INVAL, D-stream read/write/fill
commands
CCTL: CBox Control Register (IPR A0)
------------------------------30: Software ETM
0 = disabled* - diagnostic use only
16: Force NDAL parity error
0 = off* - diagnostic use only
15:11: Performance monitoring BCache access and hit type
0 - configures BCache for performance monitoring* meaningful only during performance monitoring
10: Disable CBox write packer
0 = write packer enabled* - improves write latency
9: Read timeout counter test
0 = test disabled* - use external time base for read
timeout counter
8: Software ECC
0 = use correct ECC*
7: Disable BCache errors
0 = BCache errors detected*
6: Force Hit
0 = disabled* - diagnostic use only
5:4: BCache size
00 = 128 KB* (Models 400,500)
10 = 512 KB (Model 600)
3:2: Data store speed
00 = 2 cycle read, 3 cycle write* (Model 600)
01 = 3 cycle read, 4 cycle write (Model 500)
10 = 4 cycle read, 5 cycle write (Model 400)
1: Tag store speed
0 = 3 cycle read, 3 cycle write* (Model 600)
1 = 4 cycle read, 4 cycle write (Models 400,500)
0: Enable BCache
1 = enabled
CQBIC:
======
SCR: System Configuration Register (2008 0000)
-----------------------------------------14: Halt enable
1 = BHALT to CQBIC HALTIN pin to cause halts
12: Page prefetch disable
1 = map prefetch disabled - historical latency reasons
7: Restart enable
0 = QBus restart causes ARB power-up reset*
3:1:
ICR offset address select bits
0 = no effect (AUX mode not supported)*
Configurable Machine State
E–5
ICR: Interprocessor Communication Register (2000 1F40)
-------------------------------------------------8: AUX Halt
0 = no halt (AUX mode not supported)
6: ICR interrupt enable
0 = interprocessor interrupts disabled - only
uniprocessor config. allowed
5: Local memory external access enable
0 = external access disabled* - VMS will configure map
QBMBR: Q-Bus Map Base Address Register (2008 0010)
------------------------------------------28:15: address where 8K QBus mapping registers are located
(VMS reconfigures map)
SHAC:
=====
NOTE:
all SHAC registers are subsequently configured by VMS driver
PQBBR: Port Queue Block Base Register (2000 4048)
------------------------------------------20:0: upper bits of physical address of base of Port Queue
block. Contains HW version, FW version, shared host
memory version and CI port maintenance ID at power-up.
PPR: Port Parameter Register (2000 4058)
-----------------------------------31:29: Cluster size. For SHAC value = 0.
28:16: Internal buffer length = 0* (For SHAC value = 1010 hex)
7:0: Port number.
Same as SHAC’s DSSI ID.
PMCSR: Port Maintenance Control and Status Register (2000 405C)
--------------------------------------------------------2: Interrupt enable
0 = disabled*
1: Maintenance timer disable
0 = enabled*
SGEC:
=====
NOTE:
all SGEC registers are susequently configured by VMS driver
NICSR0: Vector Address, IPL, Synch/Asynch Register (2000 8000)
------------------------------------------------------31:30: Interrupt priority
00 = 14*
29: Synch/Asynch bus master operating mode
0 = asynchronous*
15:0: Interrupt vector = 0003hex*
E–6 KA675/KA680/KA690 CPU
NICSR6: Command and Mode Register (2000 8018)
-------------------------------------30: Interrupt enable
0 = disabled*
28:25: Burst limit mode
maximum number of longwords transferred in a single
DMA burst. 1*,2,4,8 when NICSR<19>is clear;
1*,4 when set.
20: Boot message enable mode
0 = disabled*
19: Single cycle enable mode
0 = disabled*
11: Start/Stop transmission command
0 = SGEC transmission process in stopped state*
10: Start/Stop reception command
0 = SGEC reception process in stopped state*
9:8: Operating mode
00 = normal mode*
7: Disable data chaining mode
0 = frames too long for current receive buffer will be
transferred to the next buffer(s) in receive list*
6: Force collision mode (internal loopback mode only)
0 = no collision*
3: Pass bad frames mode
0 = bad frames discarded*
2:1: Address filtering mode
00 = normal mode*
NICSR7: System Base Register (2000 801C)
--------------------------------29:0: System base address - physical starting address of
the VAX system page table (unpredictable after reset)
NICSR9: Watchdog Timers Register (2000 8024)
------------------------------------31:16: Receive watchdog timeout
0 = never timeout*
default = 1250 = 2 ms
range = 72 µs (45) to 100 ms
15:0: Transmit watchdog timeout
0 = never timeout*
default = 1250 = 2 ms
range = 72 µs (45) to 100 ms
SSC:
====
SSCBAR: SSC Base Address Register (2014 0000)
-------------------------------------29:0 20140000 = Base address*
Configurable Machine State
E–7
SSCCR: SSC Configuration Register (2014 0010)
--------------------------------------27: Interrupt vector disable
0 = interrupt vector enabled*
25:24: IPL Level
00 = 14*
23: ROM access time
0 = 350 ns*
22:20: ROM size
101 = 256KB
18:16: Halt protected space
101 = 20040000 - 2007FFFF (historical)
15: Control P enable
0 = 20 spaces recognized as break*, not control-p
(historical)
14:12: Terminal UART baud rate
101 = 9600 (historical)
6: Programmable address strobe 1 ready enable (for BDR)
1 = ready asserted after address strobe
5:4: Programmable address strobe 1 enable (for BDR)
11 = read enabled, write enabled
2: Programmable address strobe 0 ready enable
0 = no ready after address strobe* - not used
1:0: Programmable address strobe 0 enable
00 = read disabled, write disabled* - not used
RXCS: Console Receiver Control and Status Register (2014 0080)
--------------------------------------------------------6: Interrupt enable
0 = disabled* - polled in console mode
TXCS: Console Transmitter Control and Status Register (2014 0088)
----------------------------------------------------------6: Interrupt enable
0 = disabled*
2: Loopback enable
0 = disabled* - diagnostic use only
0: Break transmit
0 = terminate SPACE condition*
SSCBT: SSC Bus Time Out Register (2014 0020)
-------------------------------------23:0: Bus timeout interval = 4000hex (16.384 ms)
range = 1 to FFFFFF (1 µs to 16.77 sec)
ADS0MAT: Programmable Address Strobe 0 Match Register (2014 0130)
--------------------------------------------------------29:2: Match address
0 = disabled* - not used
E–8 KA675/KA680/KA690 CPU
ADS0MAS: Programmable Address Strobe 0 Mask Register (2014 0134)
-------------------------------------------------------29:2: Mask address bits - not used
ADS1MAT: Programmable Address Strobe 1 Match Register (2014 0140)
--------------------------------------------------------29:2: Match address = 20084000 (for BDR)
ADS1MAS: Programmable Address Strobe 1 Mask Register (2014 0144)
-------------------------------------------------------29:2: Mask address bits = 7C (for BDR)
T1CR: Programmable Timer 0 Control Register (2014 0100)
-------------------------------------------------6: Interrupt enable
0 = disabled*
2: STP
0 = run after overflow*
0: RUN
0 = counter not running*
(historical)
T1CR: Programmable Timer 1 Control Register (2014 0110)
-------------------------------------------------6: Interrupt enable
0 = disabled*
2: STP
0 = run after overflow*
0: RUN
1 = counter incrementing every microsecond (historical)
TNIR: Programmable Timer Next Interval Registers (2014 0108,
-----------------------------------------2014 0118)
31:0: Timer next interval count (use 2’s complement)
range = 0* to 1.2 hours
T0IV: Programmable Timer 0 Interrupt Vector Register (2014 010C)
----------------------------------------------------------9:2: Timer interrupt vector = 78hex
T1IV: Programmable Timer 1 Interrupt Vector Registers (2014 011C)
----------------------------------------------------------9:2: Timer interrupt vector = 7Chex
TOY: Time of Year Register (2014 006C)
---------------------------------31:0: Number of 10 ms intervals since written
DLEDR: Diagnostic LED Register (2014 0030)
-----------------------------------3:0: Display bits
0 = LEDs on* (historical)
Configurable Machine State
E–9
Appendix F
NVRAM Partitioning
This appendix describes how the CPU firmware partitions the SSC 1 Kb
battery backed up (BBU) RAM.
F.1 SSC RAM Layout
The KA675/KA680/KA690 firmware uses the 1Kb of NVRAM on the SSC
for storage of firmware specific data structures and other information that
must be preserved across power cycles. This NVRAM resides in the SSC
chip starting at address 20140400. The NVRAM should not be used by
the operating systems except as documented below. This NVRAM is not
reflected in the bitmap built by the firmware.
Figure F–1: KA675/KA680/KA690 SSC NVRAM Layout
20140400
Public Data Structures
(CPMBX, etc.)
Service Vectors
Firmware Stack
Diagnostic State
201407FC
Rsvd for Customer Use
MLO-008655
F.1.1 Public Data structures
The following is a list of the public data structures in NVRAM used by the
console.
Fields that are desginated as reserved and/or internal use should not be
written, because there is no protection against such corruption.
NVRAM Partitioning
F–1
F.1.2 Console Program MailBox (CPMBX)
The Console Program MailBoX (CPMBX) is a software data structure
located at the beginning of NVRAM (20140400). The CPMBX is used to
pass information between the CPU firmware and diagnostics, VMB, or an
operating system. It consists of three bytes referred to here as NVR0,
NVR1, and NVR2.
Figure F–2: NVR0 (20140400) : Console Program MailBoX (CPMBX)
7
NVR0
6
5
4
LANGUAGE
3
2
RIP
BIP
1
0
HLT_ACT
MLO-008657
Table F–1:
Field
Name
Description
7:4
LANGUAGE
This field specifies the current selected language for displaying halt
and error messages on terminals which support MCS.
3
RIP
If set, a restart attempt is in progress. This flag must be cleared by
the operating system, if the restart succeeds.
2
BIP
If set, a bootstrap attempt is in progress. This flag must be cleared
by the operating system if the bootstrap succeeds.
1:0
HLT_ACT
Processor halt action - this field in conjunction with the conditions specified in Table 3–5 is used to control the automatic restart
/bootstrap procedure. HLT_ACT is normally written by the operating system.
0
1
2
3
:
:
:
:
Restart; if that fails, reboot; if that fails, halt.
Restart; if that fails, halt.
Reboot; if that fails, halt.
Halt.
F–2 KA675/KA680/KA690 CPU
Figure F–3: NVR1 (20140401)
7
6
5
4
3
NVR1
2
1
0
MCS
CRT
MLO-008653
Table F–2:
Field
Name
Description
2
MCS
If set, indicates that the attached terminal supports Multinational
Character Set. If clear, MCS is not supported.
1
CRT
If set, indicates that the attached terminal is a CRT. If clear,
indicates that the terminal is hardcopy.
Figure F–4: NVR2 (20140402)
7
6
NVR2
5
4
3
2
1
0
KEYBOARD
MLO-008654
Table F–3:
Field
Name
Description
7:0
KEYBOARD
This field indicates the national keyboard variant in use.
F.1.3 Firmware Stack
This section contains the stack that is used by all of the firmware, with the
exception of VMB, which has its own built in stack.
F.1.4 Diagnostic State
This area is used by the firmware resident diagnostics. This section is not
documented here.
NVRAM Partitioning
F–3
F.1.5 USER Area
The KA675/KA680/KA690 console reserves the last longword (address
201407FC) of the NVRAM for customer use. This location is not tested
by the console firmware. Its value is undefined.
F–4 KA675/KA680/KA690 CPU
Appendix G
MOP Counters
The following counters are kept for the Ethernet boot channel. All counters
are unsigned integers. V4 counters rollover on overflow. All V3 counters
"latch" at their maximum value to indicate overflow. Unless otherwise
stated, all counters include both normal and multicast traffic. Furthermore,
they include information for all protocol types. Frames received and bytes
received counters do not include frames received with errors. Table G–1
displayes the byte lengths and ordering of all the counters in both MOP
Version 3.0 and 4.0.
Table G–1: MOP Counter Block
Name
V3
V4
Off
Len
Off
Len
Description
TIME_SINCE_CREATION
00
2
00
16
Time since last zeroed.
The time
which has ellapsed, since the counters
were last zeroed. Provides a frame
of reference for the other counters by
indicating the amount of time they cover.
For MOP V3, this time is the number of
seconds. MOP V4 uses the UTC Binary
Relative Time format.
Rx_BYTES
02
4
10
8
Bytes received.
The total number
of user data bytes successfully received.
This does not include Ethernet data link
headers. This number is the number of
bytes in the Ethernet data field, which
includes any padding or length fields
when they are enabled.
These are
bytes from frames that passed hardware
filtering. When the number of frames
received is used to calculate protocol
overhead, the overhead plus bytes
received provides a measurement of the
amount of Ethernet bandwidth (over
time) consumed by frames addressed to
the local system.
MOP Counters
G–1
Table G–1 (Cont.): MOP Counter Block
Name
V3
V4
Off
Len
Off
Len
Description
Tx_BYTES
06
4
18
8
Bytes sent.
The total number of
user data bytes successfully transmitted.
This does not include Ethernet data
link headers or data link generated
retransmissions. This number is the
number of bytes in the Ethernet data
field, which includes any padding or
length fields when they are enabled.
When the number of frames sent is
used to calculate protocol overhead, the
overhead plus bytes sent provides a
measurement of the amount of Ethernet
bandwidth (over time) consumed by
frames sent by the local system.
Rx_FRAMES
0A 4
20
8
Frames received.
The total
number of frames successfully received.
These are frames that passed hardware
filtering. Provides a gross measurement
of incoming Ethernet usage by the local
system. Provides information used to
determine the ratio of the error counters
to successful transmits.
Tx_FRAMES
0E 4
28
8
Frames sent.
The total number of
frames successfully transmitted. This
does not include data link generated retransmissions. Provides a gross measurement of outgoing Ethernet usage by
the local system. Provides information
used to determine the ratio of the error
counters to successful transmits.
Rx_MCAST_BYTES
12
30
8
Multicast bytes received.
The
total number of multicast data bytes
successfully received.
This does not
include Ethernet data link headers. This
number is the number of bytes in the
Ethernet data field.
In conjunction
with total bytes received, provides a
measurement of the percentage of this
system’s receive bandwidth (over time)
that was consumed by multicast frames
addressed to the local system.
4
G–2 KA675/KA680/KA690 CPU
Table G–1 (Cont.): MOP Counter Block
Name
V3
V4
Off
Len
Off
Len
Description
Rx_MCAST_FRAMES
16
4
38
8
Multicast frames received. The total number of multicast frames successfully received. In conjunction with total frames received, provides a gross percentage of the Ethernet usage for multicast frames addressed to this system.
Tx_INIT_DEFFERED
1A 4
40
8
Frames sent, 1 initially deferred.
The total number of times that a
frame transmission was deferred on
its first transmission attempt.
In
conjunction with total frames sent,
measures Ethernet contention with no
collisions.
Tx_ONE_COLLISION
1E 4
48
8
Frames sent 1 , single collision. The
total number of times that a frame was
successfully transmitted on the second
attempt after a normal collision on
the first attempt. In conjunction with
total frames sent, measures Ethernet
contention at a level where there are
collisions but the backoff algorithm still
operates efficiently.
Tx_MULTI_COLLISION
22
50
8
Frames sent1 , multiple collisions.
The total number of times that a frame
was successfully transmitted on the
third or later attempt after normal
collisions on previous attempts.
In
conjunction with total frames sent,
measures Ethernet contention at a level
where there are collisions and the
backoff algorithm no longer operates
efficiently. NO SINGLE FRAME IS COUNTED
4
IN MORE THAN ONE OF THE ABOVE THREE
COUNTERS.
1 Only
one of these three counters will be incremented for a given frame.
MOP Counters
G–3
Table G–1 (Cont.): MOP Counter Block
Name
V3
V4
Off
Len
Off
Len
Description
TxFAIL_COUNT
26
2
-
-
2
Send failure count.
The
total number of times a transmit
attempt failed. Each time the counter
is incremented, a type of failure is
recorded. When Read-counter function
reads the counter, the list of failures
is also read.
When the counter is
set to zero, the list of failures is
cleared. In conjunction with total frames
sent, provides a measure of significant
transmit problems. TxFAIL_BITMAP
contains the possible reasons.
TxFAIL_BITMAP
2C 2
-
-
2
Send failure reason bitmap.
This bitmap lists the types of transmit
failures that occurred as summarized
below.
0
1
2
3
4
5
-
Excessive collisions.
Carrier detect failed.
Short circuit.
Open circuit.
Frame too long.
Remote failure to defer.
TxFAIL_EXCESS_COLLS
-
-
58
8
Send failure - Excessive collisions.
Exceeded the maximum number of retransmissions due to collisions. Indicates
an overload condition on the Ethernet.
TxFAIL_CARIER_CHECK
-
-
60
8
Send failure - Carrier check failed.
The data link did not sense the receive
signal that is required to accompany
the transmission of a frame. Indicates
a failure in either the transmitting or
receiving hardware. Could be caused by
either transceiver, transceiver cable, or
a babbling controller that has been cut
off.
2 V3 send/receive failures are collapsed into one counter with bitmap indicating which failures
occurred.
G–4 KA675/KA680/KA690 CPU
Table G–1 (Cont.): MOP Counter Block
Name
V3
V4
Off
Len
Off
Len
Description
TxFAIL_SHRT_CIRCUIT
-
-
68
8
Send failure - Short circuit. 3 There
is a short somewhere in the local area
network coaxial cable or the transceiver
or controller/transceiver cable has failed.
This indicates a problem either in local
hardware or global network. The two
can be distinguished by checking to see
if other systems are reporting the same
problem.
TxFAIL_OPEN_CIRCUIT
-
-
70
8
Send failure - Open circuit. 3 There
is a break somewhere in the local area
network coaxial cable. This indicates
a problem either in local hardware
or global network. The two can be
distinguished by checking to see if other
systems are reporting the same problem.
TxFAIL_LONG_FRAME
-
-
78
8
Send failure - Frame too long.
The controller or transceiver cut
off transmission at the maximum size.
This indicates a problem with the local
system. Either it tried to send a frame
that was too long or the hardware cutoff
transmission too soon.
TxFAIL_REMOTE_DEFER
-
-
80
8
Send failure - Remote failure to
3
defer.
A remote system began
transmitting after the allowed window
for collisions.
This indicates either
a problem with some other system’s
carrier sense or a weak transmitter.
3 Always
3
zero.
MOP Counters
G–5
Table G–1 (Cont.): MOP Counter Block
Name
V3
V4
Off
Len
Off
Len
Description
RxFAIL_COUNT
2A 2
-
-
2 The
Receive failure count.
total number of frames received with
some data error. Includes only data
frames that passed either physical or
multicast address comparison.
This
counter includes failure reasons in the
same way as the send failure counter. In
conjunction with total frames received,
provides a measure of data related
receive problems.
RxFAIL_BITMAP
contains the possible reasons.
RxFAIL_BITMAP
2C 2
-
-
Receive failure reason bitmap. 2
This bitmap lists the types of receive
failures that occurred as summarized
below.
0 - Block check failure.
1 - Framing error.
2 - Frame too long.
RxFAIL_BLOCK_CHECK
-
-
88
8
Receive failure - Block check error
A frame failed the CRC check. This
indicates several possible failures, such
as, EMI, late collisions, or improperly set
hardware parameters.
RxFAIL_FRAMING_ERR
-
-
90
8
Receive failure - Framing error. The
frame did not contain an integral number of 8 bit bytes. This indicates several
possible failures, such as, EMI, late collisions, or improperly set hardware parameters.
RxFAIL_LONG_FRAME
-
-
98
8
Receive failure - Frame too long. 3
The frame was discarded because it was
outside the Ethernet maximum length
and could not be received. This indicates
that a remote system is sending invalid
length frames.
2 V3 send/receive failures are collapsed into one counter with bitmap indicating which failures
occurred.
3 Always zero.
G–6 KA675/KA680/KA690 CPU
Table G–1 (Cont.): MOP Counter Block
V3
V4
Off
Len
Off
Len
UNKNOWN_DESTINATION 2E 2
A0 8
Unrecognized frame destination. The
number of times a frame was discarded
because there was no portal with the
protocol type or multicast address enabled. This includes frames received for
the physical address, the broadcast address, or a multicast address.
DATA_OVERRUN
30
2
A8 8
Data overrun.
The total number
of times the hardware lost an incoming
frame because it was unable to keep
up with the data rate. In conjunction
with total frames received, provides a
measure of hardware resource failures.
The problem reflected in this counter is
also captured as an event.
NO_SYSTEM_BUFFER
32
2
B0 8
System buffer unavailable3 The
total number of times no system buffer
was available for an incoming frame. In
conjunction with total frames received,
provides a measure of system buffer
related receive problems. The problem
reflected in this counter is also captured
as an event.
This can be any
buffer between the hardware and the
user buffers (those supplied on Receive
requests).
Further information as
to potential different buffer pools is
implementation specific.
NO_USER_BUFFER
34
2
B8 8
User buffer unavailable. 3 The
total number of times no user buffer
was available for an incoming frame
that passed all filtering. These are the
buffers supplied by users on Receive
requests.
In conjunction with total
frames received, provides a measure of
user buffer related receive problems.
The problem reflected in this counter is
also captured as an event.
Name
3 Always
Description
zero.
MOP Counters
G–7
Table G–1 (Cont.): MOP Counter Block
Name
FAIL_COLLIS_DETECT
-
V3
V4
Off
Len
Off
Len
-
G–8 KA675/KA680/KA690 CPU
C0 8
Description
Collision detect check failure. The
approximate number of times that
collision detect was not sensed after a
transmission. If this counter contains a
number roughly equal to the number of
frames sent, either the collision detect
circuitry is not working correctly or the
test signal is not implemented.
Appendix H
Programming the KFQSA Adapter
The KFQSA emulates a UQSSP controller for each ISE (Integrated Storage
Element) to which it is connected, and thus presents a separate CSR
address for each emulated controller. The KFQSA must be programmed
with a correct CSR for each ISE on the DSSI bus. Interrupt vectors for the
KFQSA are programmed automatically by the operating system.
Unlike most other Q–bus controllers, the KFQSA CSR addresses are not
set with switches or jumpers. They are contained in nonvolatile memory
on the KFQSA module, in the form of a configuration table. To access the
configuration table, the KFQSA needs to have a valid address already in
the table. This could be preprogrammed at the factory, but then you need
to have an ISE installed on the DSSI bus with the proper bus node ID that
has already been programmed. Another way to a get a valid address is
to use the service switch (Switch 1 ON = SERVICE mode) on the KFQSA.
Table H–1 shows the addresses available. It is easier to do if the switches
are set as shown for the range of addresses from 0774420 - 0774434 in the
upper portion of the table.
Table H–1: Preferred KFQSA Switch Settings
Switch 1
Switch 2
Switch 3
Switch 4
CSR Address (Octal)
on
on
on
on
off
off
off
off
on
on
off
off
on
off
on
off
0774420
0774424
0774430
0774434
(fixed)
(fixed)
(fixed)
(fixed)
0760444
0774500
0760334
0772150
(secondary TMSCP)
(primary TMSCP)
(secondary MSCP)
(primary MSCP)
Available Fixed and Floating Addresses
on
on
on
on
off
on
on
on
on
on
off
off
on
off
on
off
The address that the CSR needs to have must be determined before
programming the configuration table. To determine this address, the
Programming the KFQSA Adapter
H–1
system configuration as a whole needs to be looked at, since some devices
are assigned floating addresses, while others use the fixed addresses.
Floating addresses vary with each type of module and how many of them
are installed in the system. Because of this, any time a module is installed
or removed from the system, the CSR addresses need to be checked.
To find recommended CSR address values, use the CONFIGURE Utility at
the console prompt (>>>) as described in Section 3.7.2.
NOTE: The configure command does not look at any of the devices actually
in the system. This means that one console can be used to determine the
addresses for different systems. All of the devices in the system must be
listed in this utility, in case any of the devices present affect the address
that is being calculated.
In the following example, the system has a TK70, three RF73s connected to
a KFQSA, and a DESQA. The utility responds with the CSR address/vector
assignments for all entered devices.
>>>CONFIGURE
Enter device configuration, HELP, or EXIT
Device, Number? help
Devices:
Devices:
LPV11
KXJ11
DLV11J
RLV12
TSV05
RXV21
DMV11
DELQA
DEQNA
RRD50
RQC25
KFQSA-DISK
RV20
KFQSA-TAPE
KMV11
CXA16
CXB16
CXY08
LNV21
QPSS
DSV11
KWV11C
ADV11D
AAV11D
DRQ3B
VSV21
IBQ01
IDV11D
IAV11A
IAV11B
DESNA
IGQ11
DIV32
KWV32
KZQSA
M7577
Device,Number?
Numbers:
1 to 255, default is 1
Device, Number? TQK70
Device, Number? KFQSA-DISK,3
Device, Number? DESQA
Device, Number? EXIT
H–2 KA675/KA680/KA690 CPU
DZQ11
DRV11W
DESQA
TQK50
IEQ11
VCB01
ADV11C
VCB02
IDV11A
MIRA
KIV32
LNV24
DZV11
DRV11B
RQDX3
TQK70
DHQ11
QVSS
AAV11C
QDSS
IDV11B
ADQ32
DTCN5
M7576
DFA01
DPV11
KDA50
TU81E
DHV11
LNV11
AXV11C
DRV11J
IDV11C
DTC04
DTC05
DEQRA
Address/Vector Assignments
-774440/120 DESQA
-772150/154 KFQSA-DISK
-760334/300 KFQSA-DISK
-760340/304 KFQSA-DISK
-774500/260 TQK70
>>>
After the proper addresses have been determined, the CSR addresses need
to be programmed. To do so, enter the following command at the console
prompt (>>>):
SET HOST/UQSSP/MAINTENANCE/SERVICE n
Where,
The /service n parameter specifies the controller number of a KFQSA in
SERVICE mode (in the case of multiple KFQSAs), and n is a number in
the range 0 to 3 (from Table H–1):
0
1
2
3
is
is
is
is
for
for
for
for
address
address
address
address
0774420
0774424
0774430
0774434
Entering the SET/HOST/UQSSP/MAINTENANCE/SERVICE n command
displays the current contents of the KFQSA configuration table. For
example, suppose the first address is selected and the configuration table
is currently blank:
>>> SET HOST/UQSSP/MAINTENANCE/SERVICE 0
UQSSP Controller (774420)
Enter SET, CLEAR, SHOW, HELP, EXIT, or QUIT
Node
7
?
CSR Address
Model
-------- KFQSA ------
Type HELP for a quick reference of the available commands.
? help
Commands:
SET <node> \KFQSA
SET <node> <CSR_ADDRESS><MODEL>
CLEAR <node>
SHOW
HELP
EXIT
QUIT
set KFQSA DSSI node number
enable a DSSI device
disable a DSSI device
show current configuration
print this text
program the KFQSA
don’t program the KFQSA
Programming the KFQSA Adapter
H–3
Parameters:
<node>
<CSR_ADDRESS>
<MODEL>
0 to 7
760010 to 777774
21 (disk) or 22 (tape)
?
To add the three RF-series ISEs from the previous example, enter the
following:
? SET 0 772150 21
? SET 1 760334 21
? SET 2 760340 21
?
NOTE: Be sure to enter the addresses in the same order they were listed by
the configure utility.
Enter the SHOW command to display what has just been entered:
? SHOW
Node
0
1
2
7
?
CSR Address
Model
772150
21
760334
21
760340
21
-------- KFQSA ------
To delete an entry from the table, use the CLEAR command. For example,
to delete the entry for node 2, enter CLEAR 2 at the prompt.
When finished, enter the EXIT command to write the entries to the
configuration table.
? EXIT
programming the KFQSA ...
>>>
After programming the configuration table check that the bus node ID
plugs on the drive front panels correspond to the numbers that have been
programmed into the KFQSA. Set the KFQSA to NORMAL mode by setting
switch 1 to OFF (switches 2-4 have no effect when switch 1 is set to OFF).
Enter SHOW QBUS to verify that the configuration is as desired. You may
need to program DSSI parameters for the ISEs. Refer to Section 3.7.3.1 for
instructions on setting DSSI parameters.
H–4 KA675/KA680/KA690 CPU
Appendix I
Error Messages
The error messages issued by the KA675/KA680/KA690 firmware fall into
three categories: halt code messages, VMB error messages, and console
messages.
I.1 Machine Check Register Dump
Some error conditions, such as machine check, generate an error summary
register dump preceding the error message. For example, examining a
nonexistent memory location results in the following display.
>>>ex /p/l 7fffff0
! Examine non-existent memory.
MESR=801FF000
MEAR=11FFFFF9
MMCDSR=01111000
MOAMR=00000000
CESR=00000000
CMCDSR=0000C108
CSEAR1=00000000
CSEAR2=00000000
CIOEAR1=010FC000 CIOEAR2=000002C0 CNEAR=00000000
ICSR=00000001
PCSTS=FFFFF800
PCADR=FFFFFFF8
TBSTS=C00000E0
TBADR=00000000
NESTS=00000000
NEOADR=E014066C
NEOCMD=8000F005
NEICMD=00000000
NEDATHI=00000000 NEDATLO=00000000 CEFSTS=0000022A
CEFADR=07FFFFF0
BCETSTS=00000000 BCETIDX=00000000 BCETAG=00000000
BCEDSTS=00000700
BCEDIDX=00000008 BCEDECC=00000000 CBTCR=00004000
DSER=00000000
QBEAR=0000000F
DEAR=00000000
IPCR0=0000
ECR=000000CA
?7D MACHINE CHECK 80060000 00000000 20047ECC 20047EBD 20047EB9 B0110080
>>>
I.2 Halt Code Messages
Except on power-up, which is not treated as an error condition, the following
halt messages are issued by the firmware whenever the processor halts.
For example, if the processor encounters a HALT instruction while in kernel
mode, the processor halts and the firmware displays the following before
entering console I/O mode.
?06 HLT INST
PC = 800050D3
The number preceding the halt message is the "halt code." This number is
obtained from SAVPSL<13:8>(RESTART_CODE), IPR 43, which is saved
on any processor restart operation.
Error Messages
I–1
Table I–1:
HALT Messages
Code
Message
Description
?02
EXT HLT
External halt, caused by either console BREAK
condition, Q22–bus BHALT_L, or DBR<AUX_HLT> bit
was set while enabled.
_03
——-
Power-up, no halt message is displayed. However,
the presence of the firmware banner and diagnostic
countdown indicates this halt reason.
?04
ISP ERR
In attempting to push state onto the interrupt
stack during an interrupt or exception, the processor
discovered that the interrupt stack was mapped NO
ACCESS or NOT VALID.
?05
DBL ERR
The processor attempted to report a machine check
to the operating system, and a second machine check
occurred.
?06
HLT INST
The processor executed a HALT instruction in kernel
mode.
?07
SCB ERR3
The SCB vector had bits <1:0> equal to 3.
?08
SCB ERR2
The SCB vector had bits <1:0> equal to 2.
?0A
CHM FR ISTK
A change mode instruction was executed when
PSL<IS> was set.
?0B
CHM TO ISTK
The SCB vector for a change mode had bit <0> set.
?0C
SCB RD ERR
A hard memory error occurred while the processor was
trying to read an exception or interrupt vector.
?10
MCHK AV
An access violation or an invalid translation occurred
during machine check exception processing.
?11
KSP AV
An access violation or translation not valid occurred
during processing of a kernel stack not valid exception.
?12
DBL ERR2
Double machine check error. A machine check occured
while trying to service a machine check.
?13
DBL ERR3
Double machine check error. A machine check occured
while trying to service a kernel stack not valid
exception.
I–2 KA675/KA680/KA690 CPU
Table I–1 (Cont.):
Code
HALT Messages
Message
Description
PSL
EXC51
PSL<26:24> = 5 on interrupt or exception.
?1A
PSL
EXC61
PSL<26:24> = 6 on interrupt of exception.
?1B
PSL EXC71
PSL<26:24> = 7 on interrupt or exception.
?1D
PSL
REI51
PSL<26:24> = 5 on an REI instruction
?1E
PSL REI61
PSL<26:24> = 6 on an REI instruction.
?1F
PSL REI71
PSL<26:24> = 7 on an REI instruction.
?3F
MICROVERIFY FAILURE
Microcode power-up self-test failed.
?19
1 For
the last six cases, the VAX architecture does not allow execution on the interrupt stack
while in a mode other than kernel. In the first three cases, an interrupt is attempting to run
on the interrupt stack while not in kernel mode. In the last three cases, an REI instruction
is attempting to return to a mode other than kernel and still run on the interrupt stack.
I.3 VMB Error Messages
VMB issues the errors listed in Table I–2.
Table I–2:
VMB Error Messages
Code
Message
Description
?40
NOSUCHDEV
No bootable devices found.
?41
DEVASSIGN
Device is not present.
?42
NOSUCHFILE
Program image not found.
?43
FILESTRUCT
Invalid boot device file structure.
?44
BADCHKSUM
Bad checksum on header file.
?45
BADFILEHDR
Bad file header.
?46
BADIRECTORY
Bad directory file.
?47
FILNOTCNTG
Invalid program image format.
?48
ENDOFFILE
Premature end of file encountered.
?49
BADFILENAME
Bad file name given.
Error Messages
I–3
Table I–2 (Cont.):
VMB Error Messages
Code
Message
Description
?4A
BUFFEROVF
Program image does not fit in available memory.
?4B
CTRLERR
Boot device I/O error.
?4C
DEVINACT
Failed to initialize boot device.
?4D
DEVOFFLINE
Device is offline.
?4E
MEMERR
Memory initialization error.
?4F
SCBINT
Unexpected SCB exception or machine check.
?50
SCB2NDINT
Unexpected exception after starting program image.
?51
NOROM
No valid ROM image found.
?52
NOSUCHNODE
No response from load server.
?53
INSFMAPREG
The Q22–bus map initialization failed.
?54
RETRY
No devices bootable, retrying.
?55
IVDEVNAM
Invalid device name.
?56
DRVERR
Drive error.
I.4 Console Error Messages
The error messages listed in Table I–3 are issued in response to a console
command that has error(s).
Table I–3:
Console Error Messages
Code
Message
Description
?61
CORRUPTION
The console program database has been corrupted.
?62
ILLEGAL REFERENCE
Illegal reference. The requested reference would violate
virtual memory protection, the address is not mapped,
the reference is invalid in the specified address space,
or the value is invalid in the specified destination.
?63
ILLEGAL COMMAND
The command string cannot be parsed.
?64
INVALID DIGIT
A number has an invalid digit.
I–4 KA675/KA680/KA690 CPU
Table I–3 (Cont.):
Console Error Messages
Code
Message
Description
?65
LINE TOO LONG
The command was too large for the console to buffer.
The message is issued only after receipt of the
terminating carriage return.
?66
ILLEGAL ADRRESS
The address specified falls outside the limits of the
address space.
?67
VALUE TOO LARGE
The value specified does not fit in the destination.
?68
QUALIFIER CONFLICT
Qualifier conflict, for example, two different data sizes
are specified for an EXAMINE command.
?69
UNKNOWN QUALIFIER
The switch is unrecognized.
?6A
UNKNOWN SYMBOL
The symbolic address in an EXAMINE or DEPOSIT
command is unrecognized.
?6B
CHECKSUM
The command or data checksum of an X command
is incorrect. If the data checksum is incorrect, this
message is issued, and is not abbreviated to "Illegal
command".
?6C
HALTED
The operator entered a HALT command.
?6D
FIND ERROR
A FIND command failed either to find the RPB or 128
KB of good memory.
?6E
TIME OUT
During an X command, data failed to arrive in the time
expected (60 seconds).
?6F
MEMORY ERROR
A machine check occurred with a code indicating a read
or write memory error.
?70
UNIMPLEMENTED
Unimplemented function.
?71
NO VALUE QUALIFIER
Qualifier does not take a value.
?72
AMBIGUOUS QUALIFIER There were not enough unique characters to determine
the qualifier.
?73
VALUE QUALIFIER
Qualifier requires a value.
?74
TOO MANY QUALIFIERS
Too many qualifiers supplied for this command.
?75
TOO MANY ARGUMENTS Too many arguments supplied for this command.
?76
AMBIGUOUS COMMAND There were not enough unique characters to determine
the command.
Error Messages
I–5
Table I–3 (Cont.):
Console Error Messages
Code
Message
Description
?77
TOO FEW ARGUMENTS
Insufficient arguments supplied for this command.
?78
TYPEAHEAD OVERFLOW The typeahead buffer overflowed.
?79
FRAMING ERROR
A framing error was detected on the console serial line.
?7A
OVERRUN ERROR
An overrun error was detected on the console serial
line.
?7B
SOFT ERROR
A soft error occurred.
?7C
HARD ERROR
A hard error occurred.
?7D
MACHINE CHECK
A machine check occurred.
I–6 KA675/KA680/KA690 CPU
Appendix J
Related Documents
The following documents contain information relating to the maintenance
of systems that use the KA675/KA680/KA690 CPU module.
Title
Part Number1
Guide to Entry Systems Service Information Kits
EK–K276#–MI
KA675/KA680/KA690 CPU Technical Manual
EK–KA680–TM
VAX 4000 Site Preparation Guide
EK–387A#–SP
BA430/BA440 Enclosure Maintenance
EK–348A*–MG
BA400-Series Enclosures Storage Devices Installation Procedures
EK–BA44A–IN
DSSI Warm Swapping Guide for BA400-Series Enclosures and
KFQSA Adapters
EK–457AA–SG
DSSI VAXcluster Installation and Troubleshooting
EK–410AA–MG
MicroSystems Options
EK–192A#–MG
MicroVAX Diagnostic Monitor User’s Guide
AA–FM7A#–DN
KFQSA Storage Adapter Installation and User Manual
EK–KFQSA–IN
RF-Series Integrated Storage Element User Guide
EK–RF72D–UG
RF-Series Integrated Storage Element Service Guide
EK–RF72D–SV
1#
= current revision, which is always shipped.
Related Documents
J–1
Glossary
BFLAG
Boot FLAG is the longword supplied in the SET BFLAG and BOOT
/R5: commands that qualify the bootstrap operation. SHOW BFLAG
displays the current value.
BHALT
Q22–bus Halt signal is usually tied to the front panel Halt switch.
BIP
Boot In Progress flag in CPMBX<2>
Bugcheck
See machine check.
Cache memory
A small, high-speed memory placed between slower main memory and
the processor. A cache increases effective memory transfer rates and
processor speed.
CPMBX
Console Program Mailbox is used to pass information between operating
systems and the firmware.
CSR
Control and status register. A device or controller register that resides
in the processor’s I/O space. The CSR initiates device activity and
records its status.
CQBIC
CVAX to Q22–bus interface chip
DCOK
Q22–bus signal indicating dc power is stable. This signal is tied to the
Restart switch on the System Control Panel.
DE
Diagnostic Executive is a component of the ROM-based diagnostics
responsible for set-up, execution, and clean-up of component diagnostic
tests.
DNA
Digital Network Architecture
DMA
Direct Memory Access. Access to the memory by an I/O device that does
not require processor intervention.
EPROM
Erasable Programmable Read-Only Memory is used on some products
to store firmware. Commonly used synonyms are PROM or ROM.
Erasable by using ultraviolet light.
ECC
Error Correction Code. Code that carries out automatic error correction
by performing an exclusive or operation on the transferred data and
applying a correction mask.
Glossary–1
Factory Installed Soft- Operating system software that is loaded into a system disk during
ware (FIS)
manufacture. On site, the FIS is bootstraped in the system, prompting
a predefined menu of questions on the final configuration.
FEPROM
Flash Erasable Programmable Read-Only Memory (FEPROM) is used
on four chips on the KA675/KA680/KA690 module. FEPROMs use
electrical (bulk) erasure rather than ultraviolet erasure.
Firmware
Firmware in this document refers to VAX instruction code residing at
physical address 20040000 on the KA675/KA680/KA690. Functionally
it consists of diagnostics, bootstraps, console, and halt entry/exit code.
FRU
Field-Replacable Unit. Any system component that the field engineer
is able to replace on-site.
GPR
General Purpose Registers on the KA675/KA680/KA690 are the sixteen
standard VAX longword registers R0 through R15. The last four
registers, R12 through R15, are also known by their unique mnemonics
AP (Argument Pointer), FP (Frame Pointer), SP (Stack Pointer), and
PC (Program Counter), respectively.
Initialization
The sequence of steps that prepare the system to start. Initialization
occurs after a system has been powered up.
IPL
Interrupt Priority Level ranges from 0 to 31 (0 to 1F hex).
IPR
Internal Processor Registers on the KA65/KA680/KA690 are those
implemented by the processor chip set. These longword registers
are only accessible with the instructions MTPR (Move To Processor
Register) and MFPR (Move From Processor Register) and require
kernel mode privileges. This document uses the prefix "PR$_" when
referencing these registers.
ISE
Integrated storage element. An intelligent disk drive used on the
Digital Storage Systems Interconnect.
KA675/KA680/KA690 NVAX based Q22–bus CPU processor module with onboard cache, two
DSSI ports, and Ethernet adapter.
LED
Light Emitting Diode
Machine check
An operating system action triggered by certain system errors that can
be fatal to system operation. Once triggered, machine check handler
software analyzes the error, comparing it to predetermined failure
scenarios. Three outcomes are possible: the system continues to run,
the software program is halted, or the system crashes.
MOP
Maintenance Operations Protocol specifies message protocol for
network loopback assistance, network bootstrap, and remote console
functions.
MSCP
Mass Storage Control Protocol is used in Digital disks and tapes.
Glossary–2
ms
Millisecond (10e-3 seconds)
NVRAM
Nonvolatile RAM, on the KA675/KA680/KA690 this is 1 Kb of battery
backed-up RAM on the SSC.
PC
Program Counter or R15
PCB
Process Control Block is a data structure pointed to by the PR$_PCBB
register and contains the current process’ hardware context.
PFN
Page Frame Number is an index of a page (512 bytes) of local memory.
A PFN is derived from the bit field <23:09> of a physical address.
PR$_ICCS
Interval Clock Control and Status, IPR 24
PR$_IPL
Interrupt Priority Level, IPR 18
PR$_MAPEN
Memory Management Mapping Enable, IPR 56
PR$_PCBB
Process Control Block Base register, IPR 16
PR$_RXCS
R(X)eceive Console Status, IPR 32
PR$_RXDB
R(X)eceive Data Buffer, IPR 33
PR$_SAVISP
SAVed Interrupt Stack Pointer, IPR 41
PR$_SAVPC
SAVed Program Counter, IPR 42
PR$_SAVPSL
SAVed Program Status Longword, IPR 43
PR$_SCBB
System Control Block Base register, IPR 17
PR$_SISR
Software Interrupt Summary Register, IPR 21
PR$_TODR
Time Of Day Register, IPR 27, is commonly referred to as the Time Of
Year register or TOY clock.
PR$_TXCS
T(X)ransmit Console Status, IPR 34
PR$_TXDB
T(X)ransmit Data Buffer, IPR 35
PSL, PSW
Processor Status Longword is the VAX extension of the PSW (Processor
Status Word). The PSW (lower word) contains instruction condition
codes and is accessible by nonprivileged users; however, the upper
word contains system status information and is accessible by privileged
users.
QBMBR
Q22–bus Map Base Register found in the CQBIC determines the base
address in local memory for the scatter/gather registers.
QDSS
Q22–bus video controller for workstations
Glossary–3
QMR
Q22–bus Map Register
QNA
Q22–bus Ethernet controller module
RAM
Random Access Memory
RIP
Restart In Progress flag in CPMBX<3>
RPB
Restart Parameter Block is a software data structure used as
a communication mechanism between firmware and the operating
system. Information in this block is used by the firmware to attempt
an operating system (warm) restart.
SCB
System Control Block is a data structure pointed to by PR$_SCBB. It
contains a list of longword exception and interrupt vectors.
SGEC
Second Generation Ethernet Chip
SDD
Symptom-Directed Diagnosis. Online analysis of nonfatal system errors
in order to locate potential system fatal errors before they occur.
SHAC
Single Host Adapter Chip
SP
Stack Pointer or R14
SRM
Standard Reference Manual, as in VAX SRM
SSC
System Support Chip
µs
Microsecond (10e-6 seconds)
VAXcluster configuration
A highly integrated organization of VMS systems that communicate
over a high-speed communications path. VAXcluster configurations
have all the functions of single-node systems, plus the ability to
share CPU resources, queues, and disk storage. Like a singlenode system, the VAXcluster configuration provides a single security
and management environment. Member nodes can share the same
operating environment or serve specialized needs.
VMB
Virtual Memory Boot is the portion of the firmware dedicated to booting
the operating system.
Glossary–4
Index
A
Acceptance testing, 4–15 to 4–20
Algorithm
to find a valid RPB, 4–40
to restart operating system, 4–39
ALLCLASS, 3–24
setting, 3–32
ANALYZE/ERROR, 5–14
interpreting CPU errors using,
5–15
interpreting DMA to host
transaction faults using,
5–28
interpreting memory errors using,
5–17
interpreting system bus faults
using, 5–26
ANALYZE/SYSTEM, 5–20
B
Backplane
description, 2–14
Binary load and unload (X
command), A–34
Bits
RPB$V_DIAG, 4–32
RPB$V_SOLICT, 4–32
Boot
flags, 3–46
supported devices, 3–45, H–1
Boot Block Format, 4–30
BOOT command, A–10
Boot Flags
RPB$V_BBLOCK, 4–30
Bootstrap
conditions, 4–23
Bootstrap (cont’d)
definition of, 4–23
disk and tape, 4–30
failure, 4–24
initialization, 4–24
memory layout, 4–25
memory layout after successful
bootstrap, 4–28
network, 4–32
preparing for, 4–24
primary, 4–26
PROM, 4–31
secondary, 4–27
control passed to, 4–28
Break Enable/Disable switch, 2–8
C
9C utility, 4–16, 5–54
Comment command (!), A–36
! (comment command), A–36
Configuration, 3–1
and module order, 3–1
CONFIGURE, 3–21
CONFIGURE command, 3–21, A–11
Console commands
address space control qualifiers,
A–7
address specifiers, A–3
binary load and unload (X), A–34
BOOT, A–10
! (comment), A–36
CONFIGURE, A–11
CONTINUE, A–14
data control qualifiers, A–7
DEPOSIT, A–14
EXAMINE, A–15
FIND, A–16
Index–1
Console commands (cont’d)
HALT, A–17
HELP, A–17
INITIALIZE, A–19
keywords, A–8
list of, A–8
MOVE, A–20
NEXT, A–21
qualifier and argument
conventions, A–2
qualifiers, A–6
REPEAT, A–23
SEARCH, A–23
SET, A–25
SHOW, A–29
START, A–33
symbolic addresses, A–3
syntax, A–2
TEST, A–33
UNJAM, A–34
X (binary load and unload), A–34
Console error messages
sample of, 5–38
Console I/O mode
special characters, A–1
Console module
desription, 2–6 to 2–11
fuses, 2–10
Console port, testing, 5–64
CONTINUE command, A–14
CPU
features, 2–1 to 2–5
location, 3–1
D
DC OK Indicator
function, 2–13
on System Control Panel, 2–13
DEPOSIT command, A–14
Device Dependent Bootstrap
Procedures, 4–30
Diagnostic executive, 4–9
error field, 5–39
Index–2
Diagnostic tests
list of, 4–9
parameters for, 4–9
Diagnostics
relationship to UETP, 5–60
Diagnostics, DSSI storage devices,
5–55
Diagnostics, RF-series, 4–8
DNA Maintenance Operations
Protocol (MOP), 4–32
Documents
related, J–1
DSSI parameters, 3–23
DSSI storage device
errors, 5–55
testing, 5–55
DSSI storage device local programs
list of, 5–55
DSSI VAXcluster
capability, 3–13
configuration rules, 3–15
examples of, 3–16, 3–18
DUP driver utility, 3–23, 3–26
entering from console mode, 3–30
entering from VMS, 3–31
exiting, 3–37
E
Entry Point
definition of, C–1
Error during UETP, 5–61
diagnosing, 5–60
Error Log Utility
relationship to UETP, 5–60
Error messages
console, sample of, 5–38
EXAMINE command, A–15
Expanders
control power bus, 3–9
mass storage, 3–8
Q–bus, 3–8
F
Fans
Fan Speed Control Disable (FSC),
2–18
location, 2–17
FE utility, 5–51
Files–11 lookup, 4–30
FIND command, A–16
Firmware
commands and utilities, 3–18
power-up sequence, 4–1
updating, 6–1
Flags
restart in progress, 4–39
FORCEUNI, 3–24
Fuses
for H3604 console module, 5–62
troubleshooting, 5–62
G
General purpose registers (GPRs)
in error display, 5–41
symbolic addresses for, A–3
H
H3103 loopback connector, 5–64
H3604 I/O panel, 5–64
H8572 loopback connector, 5–64
Halt
dispatch, D–1
HALT
on bootstrap failure, 4–27
Halt actions
summary, 3–47
Halt Button
location, 2–13
HALT command, A–17
Halt protection, override, 5–52
HELP command, A–17
I
INIT, 4–24
Initial power-up test
See IPR
Initialization
following a processor halt, 4–39
prior to bootstrap, 4–24
INITIALIZE command, A–19
IPL_31, 4–25
iSYS$TEST logical name, 5–60
L
Language selection menu
conditions for display of, 4–2
example of, 4–2
messages, list of, 4–2
Local Memory Partitioning, 4–25
Log file generated by UETP
OLDUETP.LOG, 5–61
Loopback connectors
H3103, 5–64
H8572, 5–64
list of, 5–67
Loopback tests, 5–62
console port, 5–64
DSSI, 5–65
Ethernet, 5–66
Q–bus, 5–67
M
Maintenance strategy, 1–1
field feedback, 1–6
information services, 1–4
service delivery, 1–1
service tools and utilities, 1–2
Mass storage
configuration of, 3–6
rules for numbering, 3–7
Memory
acceptance testing of, 4–16
isolating FRU, 4–17, 5–52
modules, 2–5
testing, 5–52
Index–3
Memory module
desription, 2–5
installing, 3–2
order, 2–5
Module
configuration, 3–5
order, in backplane, 3–1
self-tests, 4–7, 5–67
MOM$LOAD, 4–32
MOP functions, 4–35
MOP program load sequence, 4–32
MOP, functions, 5–57
MOVE command, A–20
N
Network listening, 4–33
NEXT command, A–21
NODENAME, 3–24
setting, 3–36
NVRAM
CPMBX, F–2
partitioning, F–1
O
OLDUETP.LOG file, 5–60
Operating System
bootstrap, 4–23
restarting a halted, 4–39
Operating System Restart
definition of, 4–39
Options
adding to enclosure, 3–9 to 3–13
Over Temperature Warning indicator
system, 2–13
P
Page Frame Number Bitmap, 4–32
Parameters
for diagnostic tests, 4–9
in error display, 5–40
Patchable Control Store
Error messages, 6–9
Index–4
PFN bitmap, 4–24
POST
See Power-on self-tests
errors handled by, 5–55
Power supply
desription, 2–15 to 2–17
minimum load, 3–13
Power-on self test
See POST
Power-on self-tests
description, 4–4
errors handled by, 4–8
kernel, 4–4
mass storage, 4–8
Q–bus, 4–7
power-up
machine state, 4–20
memory layout, 4–21
Power-up mode switch
set to language inquiry, 4–1
set to run, 4–3
set to test, 4–1
Power-up sequence, 4–1
Power-up tests, 4–1
PRA0, 4–31
Primary Bootstrap, 4–26
Q
Q–bus options, recommended order,
3–5
Q22–bus Memory
and VMB, 4–28
R
Registers
initializing the general purpose,
4–25
Q22–bus Map Registers, 4–28
Related documents, J–1
REPEAT command, A–23
REQ_PROGRAM, 4–33
Restart, 4–39
Restart Button
location, 2–13
Restart parameter block (PRB),
3–46
Restart Parameter Block (RPB)
RIP flag, 4–39
RF-series ISE
diagnostics, 4–8, 5–55
errors, 5–55
RF-series ISE local programs
list of, 5–55
ROM-based diagnostics, 4–8 to 4–10
and memory testing, 5–53
console displays during, 5–38
isolating failures with, 5–42
list of, 4–9
parameters, 4–9
utilities, 4–9
RPB
initialization, D–6
locating, 4–40
RPB Signature Format, 4–40
S
Scripts, 4–10 to 4–11
list of, 4–14
SEARCH command, A–23
Secondary Bootstrap, 4–27
Self-test, for modules, 4–7, 5–67
SET BOOT device name command
use of, 3–43
SET command, A–25
SET HOST/DUP command, A–25
SHOW command, A–29
SHOW commands, 3–28
SICL messages, 5–32
converting appended MEL files,
5–35
Signature Block
PROM, 4–31
START command, A–33
Symbolic addresses, A–3
for any address space, A–6
for GPRs, A–3
System control panel, 2–12 to 2–13
System hang, 5–62
SYSTEMID, 3–24
setting, 3–36
T
Tape ISE
diagnostics, 5–55
errors, 5–55
Tape ISE local programs
list of, 5–55
Termination power, tests for, 5–65
TEST command, A–33
Tests, diagnostic
list of, 4–9
parameters for, 4–9
Troubleshooting
procedures, general, 5–1
suggestions, additional, 5–54
UETP, 5–61
U
UETINIT01.EXE image, 5–61
UETP
interpreting VMS failures with,
5–60
UETP.LOG file, 5–60
Unit number labels, 3–33
UNITNUM, 3–24
setting, 3–33
UNJAM, 4–24
UNJAM command, A–34
User Environment Test Package
(UETP)
interpreting output of, 5–60
running multiple passes of, 5–60
typical failures reported by, 5–61
Utilities, diagnostic, 4–9
V
Valid Maps, 4–28
VAXELN
and VMB, 4–27
Index–5
VAXsimPLUS, 5–3, 5–30
customizing, 5–37
enabling SICL, 5–37
installing, 5–36
Virtual Memory Boot (VMB), 4–27
definition of, 4–26
primary bootstrap, 4–26
secondary bootstrap, 4–30
VMB
boot flags, 3–46
VMS
error handling, 5–4
event record translation, 5–14
W
Warmstart, 4–39
Write-enabling
a storage element, 3–39
an RF-series storage element,
3–39 to 3–43
Write-protecting
a storage element, 3–39
an RF-series storage element,
3–39 to 3–43
an RF35 storage element, 3–39 to
3–43
X
X command (binary load and
unload), A–34
Index–6
Reader’s Comments
KA675/KA680/KA690 CPU
System Maintenance
EK–454AA–MG–001
Your comments and suggestions help us improve the quality of our publications.
Please rate the manual in the
following categories:
Excellent
Good
Accuracy (product works as described)
Completeness (enough information)
Clarity (easy to understand)
Organization (structure of subject matter)
Figures (useful)
Examples (useful)
Table of contents (ability to find topic)
Index (ability to find topic)
Page design (overall appearance)
Print quality
What I like best about this manual:
What I like least about this manual:
Additional comments or suggestions:
I found the following errors in this manual:
Page
Description
For which tasks did you use this manual?
Installation
Maintenance
Marketing
Operation/Use
Programming
System Management
Training
Other (please specify)
Name/Title
Company
Address
Phone
Date
Fair
Poor
Do Not Tear – Fold Here and Tape
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
BUSINESS REPLY MAIL
FIRST CLASS PERMIT NO. 33 MAYNARD MASS.
POSTAGE WILL BE PAID BY ADDRESSEE
DIGITAL EQUIPMENT CORPORATION
CORPORATE USER INFORMATION PRODUCTS
PKO3–1/D30
129 PARKER STREET
MAYNARD, MA 01754–9975