Skylla-i Battery Charger 24V

Li-Ion ready

Skylla-i 24/100 (3)

Skylla-i 24/100 www.victronenergy.com

Skylla-i (1+1): two outputs to charge 2 battery banks

The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery.

Skylla-i (3): three full current outputs to charge 3 battery banks

The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current.

Rugged

Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air.

Circuit boards are protected with an acrylic coating for maximum corrosion resistance.

Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.

Flexible

Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use.

Please refer to the manual for a complete overview of the possibilities.

Important features:

Synchronised parallel operation

Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details.

The right amount of charge for a lead-acid battery: variable absorption time

When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.

Preventing damage due to excessive gassing: the BatterySafe mode

If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.

Less maintenance and aging when the battery is not in use: the Storage mode

The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.

To increase battery life: temperature compensation

Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.

Battery voltage sense

In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage.

Suitable for AC and DC supply (AC-DC and DC-DC operation)

The chargers also accept a DC supply.

Use as a power supply

As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available.

Li-Ion (LiFePO4) ready

Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated

CAN bus port.

Learn more about batteries and battery charging

To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’

(available free of charge from Victron Energy and downloadable from www.victronenergy.com

).

Skylla-i 24/80 (1+1) 24/80 (3) 24/100 (1+1) 24/100 (3)

Input voltage (VAC)

Input voltage range (VAC)

Input voltage range (VDC)

Maximum AC input current @ 180 VAC

Frequency (Hz)

Power factor

Charge voltage 'absorption' (VDC) (1)

Charge voltage 'float' (VDC)

Charge voltage ‘storage’ (VDC)

Charge current (A) (2)

Charge current starter batt. (A)

Charge algorithm

Battery capacity (Ah)

Charge algorithm, Li-Ion

Temperature sensor

Can be used as power supply

Remote on-off port

CAN bus communication port (VE.Can)

Synchronised parallel operation

Alarm relay

Forced cooling

Protection

Operating temp. range

Humidity (non-condensing)

Material & Colour

Battery-connection

230 VAC-connection

Protection category

Weight kg (lbs)

Dimensions hxwxd in mm

(hxwxd in inches)

80 A

4 A

230 V

185-265 V

180-350 V

16 A

45-65 Hz

0,98

28,8 V

27,6 V

26,4 V

3 x 80 A

(max total output: 80A) n. a.

100 A

7 stage adaptive

4

20 A

3 x 100 A

(max total output: 100A) n. a.

400-800 Ah 500-1000 Ah

3 stage, with on-off control or CAN bus control

Yes

Yes

Yes (can be connected to a Li-Ion BMS)

Two RJ45 connectors, NMEA2000 protocol, galvanically isolated

Yes, with VE.Can

DPST AC rating: 240VAC/4A DC rating: 4A up to 35VDC, 1A up to 60VDC

Yes

Battery reverse polarity (fuse) Output short circuit Over temperature

-20 to 60°C (Full output current up to 40°C) max 95%

ENCLOSURE aluminium (blue RAL 5012)

M8 bolts

STANDARDS screw-clamp 10mm² (AWG 7)

IP 21

7 kg (16 lbs)

405 x 250 x 150 mm

(16.0 x 9.9 x 5.9 inch)

EN 60335-1, EN 60335-2-29

EN 55014-1, EN 61000-6-3, EN 61000-3-2

Safety

Emission

Immunity

1) Output voltage range 20-36 V.

Can be set with rotary switch or

potentiometers.

EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3

2) Up to 40°C (100°F) ambient.

Output will reduce to 80% at 50°C, and to 60% at 60°C.

BMV 700 Battery Monitor

The BMV 700 Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current.

The software includes complex calculation algorithms, like Peukert’s formula, to exactly determine the state of charge of the battery. The BMV 700 selectively displays battery voltage, battery current, consumed Ah or time to go.

Skylla-i Control

The Skylla-i Control panel provides remote control and monitoring of the charge process with LED status indication. In addition, the remote panel also offers input current adjustment that can be used to limit the input current and thus the power drawn from the AC supply. This is particularly useful when operating the charger from limited shore power or small gensets. The panel can also be used to change several battery charging parameters.

Several control panels can be connected to one charger or to a set of synchronised and parallel connected chargers.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands

General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40

E-mail: [email protected] | www.victronenergy.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement