Oldham WX4 Controller Product Literature (English)

Oldham WX4 Controller Product Literature (English)
WX4

4-Channel Controller

4-20mA or Bridge Sensor Inputs
 Programmable Relays
 RS-232/485 ModBus

Wireless Options
 Graphical Display
CERTIFICATIONS
The Fixed Gas Detection Experts
www.oldhamgas.com
RELIABLE
The WX4 controller is designed to offer reliability and
functionality.




Security mode allows for lockout of critical parameters
NEMA 4X/7 Enclosures
Non-volatile memory retains all configuration data
CSA Div 2 A,B,C,D and C22.2 No. 152 approved
VERSATILE
The WX4 controller can be configured in multiple ways
to meet your application needs. It offers analog, digital,
and wireless capability and comes standard with two
programmable alarm relays.
 Accepts four 4-20mA, bridge, or wireless inputs
 Provides 4-20mA, ModBus RTU, or wireless outputs
 Wireless Communication (opt)
 Magnetic and Tripod mounting options available
 Multiple enclosure options
 Multiple power supply options including solar
 Two programmable SPDT alarm relays and a common

APPLICATIONS






Oil and Gas Industry
Offshore Drilling
Utilities and Power
Petrochemical Industry
Municipal Water and Waste Treatment
Food and Beverage Production
horn driver standard
Six programmable alarm relays (opt)
EASY TO USE
The WX4 is designed to offer the user convenient
features and ease of use.




Touch Key and Non-Intrusive (magnetic) Operation
Graphic Display
Visual Alarm LEDs
Built-In Piezo Siren
DISPLAY SCREENS
Main Screen
Bar Graph Screen
Trend Screen
WIRELESS
Wireless communication is becoming increasingly
popular in gas detection, and it is sometimes the only
way to ensure safety in existing infrastructure or remote
locations.
The WX4 can be configured to accept wireless inputs
from an OLCT 200 transmitter or communicate wirelessly
to a compatible ModBus master device. Additionally, the
WX4’s wireless option offers the following features:
900MHz or 2.4GHz FHSS
10mW – 1W Adjustable Tx Power
CSA Div 1 and DIV 2 Antennas
256-bit Encryption
Indoor Range up to 3000' (900 meters)
Outdoor Range up to 10 miles (16 km)
 -100dBm Receiver Sensitivity
 Battery & Solar Powered Options






TECHNICAL SPECIFICATIONS
Display
LCD (128 x 64 pixel) with backlighting
Indicators
Six discrete LEDs for three common alarm levels, fault,
calibration mode, and keypad function
Interface
Buttons
Five buttons - dual touch key and magnetic
(non-intrusive)
Inputs
Four channels (either 4x 4-20mA or 4x bridge sensor)
4-20mA inputs are into 100 ohm impedance and include
+power for each channel for routing power to
2- or 3-wire transmitters
Bridge sensor inputs allow for adjustable sensor
excitation and balance settings
Up to 4 channels can be received wirelessly from an
OLCT 200 transmitter configured with a wireless package
Outputs
Opt. 4-channel 4-20mA output
(max load 800 ohms @24VDC)
Relays
Std. Two programmable 5amp, 30VDC or 250VAC
resistive Form C
OLDHAM also offers a variety of wireless solutions
compatible with the WX4, including wireless
transmitters, controllers, and solar-powered field
monitors as well as wireless repeaters and accessories.
Opt. Six programmable 5amp, 30VDC or 250VAC
resistive Form C
All relays are programmable and allow for voting based
on the alarm state of each of the four channels
ModBus
RS-232 or RS-485 ModBus RTU master or slave
(9600 baud)
Power Supply
Std. 100-240 VAC / 24VAC 10W
Opt. 100-240 VAC / 24VAC 50W
Opt. 100-240 VAC / 24VAC 120W
Opt. Solar / Battery Power (see factory for availability)
Wireless
900MHz or 2.4GHz FHSS
(Frequency Hopping Spread Spectrum)
256-bit AES Encryption (meets FIPS-197)
10mW - 1W adjustable transmit power (900Mhz);
120mW (2.4GHz)
Enclosure
OLCT 200
WX 16
Non-Metallic Wall Mount
-NEMA 4X / IP66; for Div.2 Groups A,B,C,D
-14.10" (358mm) H x 11.25" (286mm) W x 7.25" (184mm) D
Painted Steel Wall Mount
-NEMA 4 / IP66; for Div.2 Groups A,B,C,D
-13.65" (347mm) H x 9.84" (504mm) W x 6.20" (158mm) D
Stainless Steel Wall Mount
-NEMA 4X / IP66; for Div.2 Groups A,B,C,D
-13.65" (347mm) H x 9.84" (504mm) W x 6.20" (158mm) D
Explosion-Proof Aluminum Wall Mount
-NEMA 4/7, for Div.1 & Div. 2 Groups B,C,D
-14.25" (362mm) H x 13.00" (330mm) W x 6.25" (159mm) D
Operating
Temp
-25°C to 60°C
Humidity
0% - 90% Relative Humidity; Non-Condensing
Approvals
CSA C22.2 No 152 for combustibles
CSA C22.2 No 1010.1 and ISA S82.02
UL 1604 / CSA C22.2 No 213
(Div 2 Groups A,B, C, D)
WX64
EN55011 and EN61000
ORDERING GUIDE
WX4
ts
ts
ob
s
St
r
R
el
ay
er
Po
w
es
s
pu
W
ire
le
s
ut
lO
D
ig
ita
lo
g
O
ut
pu
s
ut
In
p
na
A
lo
g
e
ur
A
na
lo
s
En
c
EXAMPLE: WX4-11010220
WX4ENCLOSURE
1
2
3
4
Non-Metallic, NEMA 4x
Painted Steel, NEMA 4
Stainless Steel, NEMA 4x
Aluminum, NEMA 4X/7, XP
A WX4 controller with non-metallic housing
configured with 4-channel 4-20mA inputs, ModBus
RTU, a 50W power supply, and eight programmable
relays.
INPUTS
OUTPUT
OUTPUT
WIRELESS
1 4x 4-20mA
2 4x Bridge Sensor
0None
1 4x 4-20mA
0None
1RS-232/485
ModBus RTU
0None
1900MHz
22.4Ghz
~ Consult factory
for antenna options
POWER
1 10W, Div 2.
2 50W, Div 2.
3 120W , Div 2.
~ Consult factory
for solar options.
RELAYS
STROBES
1 2x Programmable
2 8x Programmable
0None
1 Red (Div 2)
2 Amber (Div 2)
3 Blue (Div 2)
4 Green (Div 2)
5 Strobe/Horn Combo (IP66)
ACCESSORIES
agnetic Mounting Kit (P/N 10-0319)
M
100db Piezo Alarm (P/N 1000-1892)
 Human Machine Interface (HMI) Software
(P/N WX-HMI)
 Solar / Battery Options (Consult factory)
 Wireless Antenna Options (Consult Factory)
 Div 2 Quick Connector and Cable Set Options
(Consult Factory)


OUR FIXED DETECTOR RANGE
OLCT 200
OLCT 10
OLCT 60
www.oldhamgas.com
OLCT 100
OLCT 60 / OLCT IR
OLCT 80
CTX 300
iTrans 2
OLCT IR
AMERICAS
Tel.: +1-713-559-9280
Fax: +1-281-292-2860
[email protected]
Flame Detector
EUROPE
Tel.: +33-3-21-60-80-80
Fax: +33-3-21-60-80-00
[email protected]
ASIA PACIFIC
Tel.: +86 21 3127 6373
Fax: +86 21 3127 6365
[email protected]
WX4_Lit_Eng_A4_7Sept2015
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement