C6 Multicomponent Hydrocarbon Mixture (Helium) in Methane

C6 Multicomponent Hydrocarbon Mixture (Helium) in Methane
Safety Data Sheet
according to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EC) No. 453/2010
C6 MULTI-COMPONENT HYDROCARBON MIXTURE (Helium) in
METHANE
Date of issue: 24/11/2015
Revision date: 24/11/2015
:
Version: 1.0
AL736
Danger
SECTION 1: Identification of the substance/mixture and of the company/undertaking
1.1.
Product identifier
SDS no
1.2.
: AL736
Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses
: Industrial and professional. Perform risk assessment prior to use.
Test gas/Calibration gas.
Laboratory use.
Contact supplier for more information on uses.
Uses advised against
: Consumer use.
1.3.
Details of the supplier of the safety data sheet
Company identification
: Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road
3004
Melbourne VIC
Australia
+61 3 9697 9888
ALAEnquiries@AirLiquide.com
1.4.
Emergency telephone number
Emergency telephone number
: 1800 812 588
SECTION 2: Hazards identification
2.1.
Classification of the substance or mixture
Classification according to Regulation (EC) No. 1272/2008 [CLP]
Physical hazards
Flammable gases, Category 1
H220
Gases under pressure : Compressed gas
H280
Classification according to Directive 67/548/EEC [DSD] or 1999/45/EC [DPD]
Not classified as dangerous substance / mixture.
2.2.
Label elements
Labelling according to Regulation (EC) No. 1272/2008 [CLP]
Hazard pictograms (CLP)
:
Signal word (CLP)
: Danger
Hazard statements (CLP)
: H220 - Extremely flammable gas.
H280 - Contains gas under pressure; may explode if heated.
GHS02
GHS04
Precautionary statements (CLP)
- Prevention : P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
- Response : P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P381 - Eliminate all ignition sources if safe to do so.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
1/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
- Storage : P403 - Store in a well-ventilated place.
2.3.
Other hazards
: None.
SECTION 3: Composition/information on ingredients
3.1.
Substance : Not applicable
3.2.
Mixture
Name
Product identifier
%
Classification according to
Directive 67/548/EEC
Classification according to
Regulation (EC) No. 1272/2008
[CLP]
Methane
(CAS No) 74-82-8
(EC no) 200-812-7
(EC index no) 601-001-00-4
(REACH-no) *1
(CAS No) 74-84-0
(EC no) 200-814-8
(EC index no) 601-002-00-X
(REACH-no) *2
(CAS No) 124-38-9
(EC no) 204-696-9
(EC index no)
(REACH-no) *1
(CAS No) 7727-37-9
(EC no) 231-783-9
(EC index no)
(REACH-no) *1
(CAS No) 74-98-6
(EC no) 200-827-9
(EC index no) 601-003-00-5
(REACH-no) 01-2119486944-21
(CAS No) 7440-59-7
(EC no) 231-168-5
(EC index no)
(REACH-no) *1
(CAS No) 106-97-8
(EC no) 203-448-7
(EC index no) 601-004-00-0
(REACH-no) 01-2119474691-32
(CAS No) 75-28-5
(EC no) 200-857-2
(EC index no) 601-004-00-0
(REACH-no) 01-2119485395-27
(CAS No) 110-54-3
(EC no) 203-777-6
(EC index no) 601-037-00-0
Balance
F+; R12
Flam. Gas 1, H220
Press. Gas (Comp.), H280
0 - 10
F+; R12
Flam. Gas 1, H220
Press. Gas (Comp.), H280
0-5
Not classified
Press. Gas (Liq.), H280
0-5
Not classified
Press. Gas (Comp.), H280
0-5
F+; R12
Flam. Gas 1, H220
Press. Gas (Liq.), H280
0-2
Not classified
Press. Gas (Comp.), H280
0-1
F+; R12
Flam. Gas 1, H220
Press. Gas (Liq.), H280
0-1
F+; R12
Flam. Gas 1, H220
Press. Gas (Liq.), H280
0 - 0.1
F; R11
Repr.Cat.3; R62
Xn; R65
Xn; R48/20
Xi; R38
N; R51/53
R67
Flam. Liq. 2, H225
Repr. 2, H361f
Asp. Tox. 1, H304
STOT RE 2, H373
Skin Irrit. 2, H315
STOT SE 3, H336
Aquatic Chronic 2, H411
pentane
(CAS No) 109-66-0
(EC no) 203-692-4
(EC index no) 601-006-00-1
0 - 0.1
F+; R12
Xn; R65
R66
R67
N; R51/53
Flam. Liq. 2, H225
Asp. Tox. 1, H304
STOT SE 3, H336
Aquatic Chronic 2, H411
Isopentane
(CAS No) 78-78-4
(EC no) 201-142-8
(EC index no) 601-006-00-1
0 - 0.1
F+; R12
Xn; R65
N; R51/53
R66
R67
Flam. Liq. 1, H224
Asp. Tox. 1, H304
STOT SE 3, H336
Aquatic Chronic 2, H411
Ethane
Carbon dioxide
Nitrogen
Propane
Helium
Butane n-
Isobutane
n-hexane
Full text of R- and H-statements: see section 16
Contains no other components or impurities which will influence the classification of the product.
*1: Listed in Annex IV / V REACH, exempted from registration.
*2: Registration deadline not expired.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
2/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
*3: Registration not required: Substance manufactured or imported < 1t/y.
SECTION 4: First aid measures
4.1.
Description of first aid measures
- Inhalation
: Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep
victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped.
- Skin contact
: Adverse effects not expected from this product.
- Eye contact
: Adverse effects not expected from this product.
- Ingestion
: Ingestion is not considered a potential route of exposure.
4.2.
Most important symptoms and effects, both acute and delayed
: In high concentrations may cause asphyxiation. Symptoms may include loss of
mobility/consciousness. Victim may not be aware of asphyxiation.
Refer to section 11.
4.3.
Indication of any immediate medical attention and special treatment needed
: None.
SECTION 5: Firefighting measures
5.1.
Extinguishing media
- Suitable extinguishing media
: Water spray or fog.
- Unsuitable extinguishing media
: Carbon dioxide.
Do not use water jet to extinguish.
5.2.
Special hazards arising from the substance or mixture
Specific hazards
: Exposure to fire may cause containers to rupture/explode.
Hazardous combustion products
: Incomplete combustion may form carbon monoxide.
5.3.
Advice for fire-fighters
Specific methods
: Use fire control measures appropriate for the surrounding fire. Exposure to fire and heat
radiation may cause gas receptacles to rupture. Cool endangered receptacles with water spray
jet from a protected position. Prevent water used in emergency cases from entering sewers and
drainage systems.
If possible, stop flow of product.
Use water spray or fog to knock down fire fumes if possible.
Do not extinguish a leaking gas flame unless absolutely necessary. Spontaneous/explosive reignition may occur. Extinguish any other fire.
Move containers away from the fire area if this can be done without risk.
Special protective equipment for fire fighters
: In confined space use self-contained breathing apparatus.
Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire
fighters.
Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full
face mask.
Standard EN 469 - Protective clothing for firefighters. Standard - EN 659: Protective gloves for
firefighters.
SECTION 6: Accidental release measures
6.1.
Personal precautions, protective equipment and emergency procedures
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
3/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
: Try to stop release.
Evacuate area.
Consider the risk of potentially explosive atmospheres.
Eliminate ignition sources.
Ensure adequate air ventilation.
Act in accordance with local emergency plan.
Stay upwind.
6.2.
Environmental precautions
: Try to stop release.
6.3.
Methods and material for containment and cleaning up
: Ventilate area.
6.4.
Reference to other sections
: See also sections 8 and 13.
SECTION 7: Handling and storage
7.1.
Precautions for safe handling
Safe use of the product
: The substance must be handled in accordance with good industrial hygiene and safety
procedures.
Only experienced and properly instructed persons should handle gases under pressure.
Consider pressure relief device(s) in gas installations.
Ensure the complete gas system was (or is regularily) checked for leaks before use.
Do not smoke while handling product.
Use only properly specified equipment which is suitable for this product, its supply pressure and
temperature. Contact your gas supplier if in doubt.
Assess the risk of potentially explosive atmospheres and the need for explosion-proof
equipment.
Purge air from system before introducing gas.
Take precautionary measures against static discharge.
Keep away from ignition sources (including static discharges).
Consider the use of only non-sparking tools.
Do not breathe gas.
Avoid release of product into atmosphere.
Safe handling of the gas receptacle
: Refer to supplier's container handling instructions.
Do not allow backfeed into the container.
Protect cylinders from physical damage; do not drag, roll, slide or drop.
When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed
to transport cylinders.
Leave valve protection caps in place until the container has been secured against either a wall
or bench or placed in a container stand and is ready for use.
If user experiences any difficulty operating cylinder valve discontinue use and contact supplier.
Never attempt to repair or modify container valves or safety relief devices.
Damaged valves should be reported immediately to the supplier.
Keep container valve outlets clean and free from contaminants particularly oil and water.
Replace valve outlet caps or plugs and container caps where supplied as soon as container is
disconnected from equipment.
Close container valve after each use and when empty, even if still connected to equipment.
Never attempt to transfer gases from one cylinder/container to another.
Never use direct flame or electrical heating devices to raise the pressure of a container.
Do not remove or deface labels provided by the supplier for the identification of the cylinder
contents.
Containers should be stored in the vertical position and properly secured to prevent them from
falling over.
7.2.
Conditions for safe storage, including any incompatibilities
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
4/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
: Observe all regulations and local requirements regarding storage of containers.
Containers should not be stored in conditions likely to encourage corrosion.
Container valve guards or caps should be in place.
Containers should be stored in the vertical position and properly secured to prevent them from
falling over.
Stored containers should be periodically checked for general condition and leakage.
Keep container below 50°C in a well ventilated place.
Store containers in location free from fire risk and away from sources of heat and ignition.
Keep away from combustible materials.
Segregate from oxidant gases and other oxidants in store.
All electrical equipment in the storage areas should be compatible with the risk of a potentially
explosive atmosphere.
7.3.
Specific end use(s)
: None.
SECTION 8: Exposure controls/personal protection
8.1.
Control parameters
n-hexane (110-54-3)
OEL : Occupational Exposure Limits
United Kingdom
WEL - LTEL - UK [mg/m³]
WEL - LTEL - UK [ppm]
72 mg/m³
20 ppm
pentane (109-66-0)
OEL : Occupational Exposure Limits
United Kingdom
WEL - LTEL - UK [mg/m³]
WEL - LTEL - UK [ppm]
1800 mg/m³
600 ppm
Isopentane (78-78-4)
OEL : Occupational Exposure Limits
United Kingdom
WEL - LTEL - UK [mg/m³]
WEL - LTEL - UK [ppm]
1800 mg/m³
600 ppm
Butane n- (106-97-8)
OEL : Occupational Exposure Limits
United Kingdom
WEL - LTEL - UK [mg/m³]
WEL - LTEL - UK [ppm]
WEL - STEL - UK [mg/m³]
WEL - STEL - UK [ppm]
1450 mg/m³
600 ppm
1810 mg/m³
750 ppm
Carbon dioxide (124-38-9)
OEL : Occupational Exposure Limits
United Kingdom
WEL - LTEL - UK [mg/m³]
WEL - LTEL - UK [ppm]
WEL - STEL - UK [mg/m³]
WEL - STEL - UK [ppm]
9150 mg/m³
5000 ppm
27400 mg/m³
15000 ppm
DNEL (Derived-No Effect Level) : No data available.
PNEC (Predicted No-Effect Concentration) : No data available.
8.2.
Exposure controls
8.2.1.
Appropriate engineering controls
: Provide adequate general and local exhaust ventilation.
Systems under pressure should be regularily checked for leakages.
Ensure exposure is below occupational exposure limits (where available).
Keep concentrations well below lower explosion limits.
Gas detectors should be used when flammable gases/vapours may be released.
Consider work permit system e.g. for maintenance activities.
8.2.2.
Individual protection measures, e.g. personal protective equipment
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
5/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
: A risk assessment should be conducted and documented in each work area to assess the risks
related to the use of the product and to select the PPE that matches the relevant risk. The
following recommendations should be considered:
PPE compliant to the recommended EN/ISO standards should be selected.
• Eye/face protection
: Wear safety glasses with side shields.
Standard EN 166 - Personal eye-protection.
• Skin protection
- Hand protection
: Wear working gloves when handling gas containers.
Standard EN 388 - Protective gloves against mechanical risk.
- Other
: Consider the use of flame resistant anti-static safety clothing.
Standard EN ISO 14116 - Limited flame spread materials.
Standard EN ISO 1149-5 - Protective clothing: Electrostatic properties.
Wear safety shoes while handling containers.
Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
• Respiratory protection
: Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be
used in oxygen-deficient atmospheres.
Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full
face mask.
• Thermal hazards
: None necessary.
8.2.3.
Environmental exposure controls
: Refer to local regulations for restriction of emissions to the atmosphere. See section 13 for
specific methods for waste gas treatment.
SECTION 9: Physical and chemical properties
9.1.
Information on basic physical and chemical properties
Appearance

Physical state at 20°C / 101.3kPa
: Gas.

Colour
Odour threshold
: Mixture contains one or more component(s) which have the following colour(s):
Colourless.
: There may be no odour warning properties, odour is subjective and inadequate to warn of
overexposure.
Mixture contains one or more component(s) which have the following odour(s):
Stenchant often added. Sweetish.
: Odour threshold is subjective and inadequate to warn of overexposure.
pH value
: Not applicable for gas-mixtures.
Molar mass
: Not applicable for gas-mixtures.
Melting point
: Not applicable for gas-mixtures.
Boiling point
: Not applicable for gas-mixtures.
Flash point
: Not applicable for gas-mixtures.
Evaporation rate (ether=1)
: Not applicable for gas-mixtures.
Flammability range
: Flammability range not available.
Vapour pressure [20°C]
: Not applicable.
Vapour pressure [50°C]
: Not applicable.
Relative density, gas (air=1)
: Lighter or similar to air.
Solubility in water
: Solubility in water of component(s) of the mixture :
• Butane n-: 88 mg/l • Carbon dioxide: 2000 mg/l Completely soluble. • Ethane: 61 mg/l •
Helium: 1.5 mg/l • Isobutane: 54 mg/l • Methane: 26 mg/l • Nitrogen: 20 mg/l • Propane:
75 mg/l
: Not applicable for gas-mixtures.
Odour
Partition coefficient n-octanol/water [log Kow]
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
6/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
Auto-ignition temperature
: Not known.
Viscosity [20°C]
: Not applicable.
Explosive Properties
: Not applicable.
Oxidising Properties
: Not applicable.
9.2.
Other information
Other data
: None.
SECTION 10: Stability and reactivity
10.1.
Reactivity
10.2.
Chemical stability
: No reactivity hazard other than the effects described in sub-sections below.
: Stable under normal conditions.
10.3.
Possibility of hazardous reactions
: Can form explosive mixture with air.
May react violently with oxidants.
10.4.
Conditions to avoid
: Keep away from heat/sparks/open flames/hot surfaces. – No smoking.
10.5.
Incompatible materials
: None known
10.6.
Hazardous decomposition products
: Under normal conditions of storage and use, hazardous decomposition products should not be
produced.
SECTION 11: Toxicological information
11.1.
Information on toxicological effects
Acute toxicity
: Classification criteria are not met.
Toxicological effects not expected from this product if occupational exposure limit values are
not exceeded.
Propane (74-98-6)
LC50 inhalation rat (ppm)
Skin corrosion/irritation
20000 ppm/4h
: No known effects from this product.
Serious eye damage/irritation
: No known effects from this product.
Respiratory or skin sensitisation
: No known effects from this product.
Germ cell mutagenicity
: No known effects from this product.
Carcinogenicity
: No known effects from this product.
Toxic for reproduction : Fertility
: No known effects from this product.
Toxic for reproduction : unborn child
: No known effects from this product.
STOT-single exposure
: No known effects from this product.
STOT-repeated exposure
: No known effects from this product.
Aspiration hazard
: Not applicable for gases and gas mixtures.
SECTION 12: Ecological information
12.1.
Toxicity
Assessment
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
: Classification criteria are not met.
EN (English)
SDS Ref.: AL736
7/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
n-hexane (110-54-3)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
pentane (109-66-0)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
Isopentane (78-78-4)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
Butane n- (106-97-8)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
14.2 mg/l
7.7 mg/l
24.1 mg/l
Isobutane (75-28-5)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
16.3 mg/l
8.6 mg/l
28 mg/l
Propane (74-98-6)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
27.1 mg/l
11.9 mg/l
49.9 mg/l
Ethane (74-84-0)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
46.6 mg/l
16.5 mg/l
91.4 mg/l
Carbon dioxide (124-38-9)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
Helium (7440-59-7)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
Nitrogen (7727-37-9)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
No data available.
No data available.
No data available.
Methane (74-82-8)
EC50 48h - Daphnia magna [mg/l]
EC50 72h - Algae [mg/l]
LC50 96 h - Fish [mg/l]
69.4 mg/l
19.4 mg/l
147.5 mg/l
12.2.
Persistence and degradability
Assessment
12.3.
Assessment
12.4.
: No data available.
Bioaccumulative potential
: No data available.
Mobility in soil
Assessment
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
: No data available.
EN (English)
SDS Ref.: AL736
8/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
12.5.
Results of PBT and vPvB assessment
Assessment
12.6.
: Not classified as PBT or vPvB.
Other adverse effects
Effect on the ozone layer
: None.
Effect on global warming
: Contains greenhouse gas(es) not covered by Regulation (EC) 842/2006.
SECTION 13: Disposal considerations
13.1.
Waste treatment methods
Contact supplier if guidance is required.
Do not discharge into areas where there is a risk of forming an explosive mixture with air.
Waste gas should be flared through a suitable burner with flash back arrestor.
Do not discharge into any place where its accumulation could be dangerous.
Ensure that the emission levels from local regulations or operating permits are not exceeded.
Refer to the EIGA code of practice Doc.30 "Disposal of Gases", downloadable at
http://www.eiga.org for more guidance on suitable disposal methods.
List of hazardous waste codes (from
Commission Decision 2001/118/EC)
13.2.
: 16 05 04: Gases in pressure containers (including halons) containing dangerous substances.
Additional information
: None.
SECTION 14: Transport information
14.1.
UN number
UN-No.
14.2.
: 1954
UN proper shipping name
Transport by road/rail (ADR/RID)
: COMPRESSED GAS, FLAMMABLE, N.O.S. (Methane, Propane)
Transport by air (ICAO-TI / IATA-DGR)
: Compressed gas, flammable, n.o.s. (Methane, Propane)
Transport by sea (IMDG)
: COMPRESSED GAS, FLAMMABLE, N.O.S. (Methane, Propane)
14.3.
Transport hazard class(es)
Labelling
:
2.1 : Flammable gases
Transport by road/rail (ADR/RID)
Class
: 2
Classification code
: 1F
Hazard identification number
: 23
Tunnel Restriction
: B/D - Tank carriage : Passage forbidden through tunnels of category B, C, D and E. Other
carriage : Passage forbidden through tunnels of category D and E
Transport by air (ICAO-TI / IATA-DGR)
Class / Div. (Sub. risk(s))
: 2.1
Transport by sea (IMDG)
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
9/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
Class / Div. (Sub. risk(s))
: 2.1
Emergency Schedule (EmS) - Fire
: F-D
Emergency Schedule (EmS) - Spillage
: S-U
14.4.
Packing group
Transport by road/rail (ADR/RID)
: Not applicable
Transport by air (ICAO-TI / IATA-DGR)
: Not applicable
Transport by sea (IMDG)
: Not applicable
14.5.
Environmental hazards
Transport by road/rail (ADR/RID)
: None.
Transport by air (ICAO-TI / IATA-DGR)
: None.
Transport by sea (IMDG)
: None.
14.6.
Special precautions for user
Packing Instruction(s)
Transport by road/rail (ADR/RID)
: P200
Transport by air (ICAO-TI / IATA-DGR)
Passenger and Cargo Aircraft
: Forbidden
Cargo Aircraft only
: 200
Transport by sea (IMDG)
: P200
Special transport precautions
: Avoid transport on vehicles where the load space is not separated from the driver's
compartment.
Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the
event of an accident or an emergency.
Before transporting product containers:
- Ensure there is adequate ventilation.
- Ensure that containers are firmly secured.
- Ensure cylinder valve is closed and not leaking.
- Ensure valve outlet cap nut or plug (where provided) is correctly fitted.
- Ensure valve protection device (where provided) is correctly fitted.
14.7.
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
: Not applicable.
SECTION 15: Regulatory information
15.1.
Safety, health and environmental regulations/legislation specific for the substance or mixture
EU-Regulations
Seveso directive 96/82/EC
: Covered.
National regulations
National legislation
: Ensure all national/local regulations are observed.
Water hazard class (WGK)
: -
15.2.
Chemical safety assessment
: A CSA does not need to be carried out for this product.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
10/11
C6 MULTI-COMPONENT
HYDROCARBON MIXTURE
(Helium) in METHANE
SDS Ref.: AL736
SECTION 16: Other information
Indication of changes
: Revised safety data sheet in accordance with commission regulation (EU) No 453/2010.
Training advice
: Ensure operators understand the flammability hazard. Receptacle under pressure.
Further information
: This Safety Data Sheet has been established in accordance with the applicable European
Union legislation. Classification in accordance with calculation methods of regulation (EC)
1272/2008 CLP / (EC) 1999/45 DPD.
Full text of R-, H- and EUH-statements
Hazardous to the aquatic environment — Chronic Hazard, Category 2
Aspiration hazard, Category 1
Flammable gases, Category 1
Flammable liquids, Category 1
Flammable liquids, Category 2
Gases under pressure : Compressed gas
Gases under pressure : Liquefied gas
Reproductive toxicity, Category 2
Skin corrosion/irritation, Category 2
Specific target organ toxicity — Repeated exposure, Category 2
Specific target organ toxicity — Single exposure, Category 3, Narcosis
Extremely flammable gas
Extremely flammable liquid and vapour
Highly flammable liquid and vapour
Contains gas under pressure; may explode if heated
May be fatal if swallowed and enters airways
Causes skin irritation
May cause drowsiness or dizziness
Suspected of damaging fertility
May cause damage to organs through prolonged or repeated exposure
Toxic to aquatic life with long lasting effects
Highly flammable
Extremely flammable
Irritating to skin
Harmful: danger of serious damage to health by prolonged exposure
through inhalation
Toxic to aquatic organisms, may cause long-term adverse effects in the
aquatic environment
Possible risk of impaired fertility
Harmful: may cause lung damage if swallowed
Repeated exposure may cause skin dryness or cracking
Vapours may cause drowsiness and dizziness
Highly flammable
Extremely flammable
Dangerous for the environment
Irritant
Harmful
Aquatic Chronic 2
Asp. Tox. 1
Flam. Gas 1
Flam. Liq. 1
Flam. Liq. 2
Press. Gas (Comp.)
Press. Gas (Liq.)
Repr. 2
Skin Irrit. 2
STOT RE 2
STOT SE 3
H220
H224
H225
H280
H304
H315
H336
H361f
H373
H411
R11
R12
R38
R48/20
R51/53
R62
R65
R66
R67
F
F+
N
Xi
Xn
DISCLAIMER OF LIABILITY
: Before using this product in any new process or experiment, a thorough material compatibility
and safety study should be carried out.
Details given in this document are believed to be correct at the time of going to press.
Whilst proper care has been taken in the preparation of this document, no liability for injury or
damage resulting from its use can be accepted.
End of document
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road 3004
Melbourne VIC Australia
+61 3 9697 9888
EN (English)
SDS Ref.: AL736
11/11