Universal trip amplifier 4131 – Input for RTD, TC, Ohm, potentiometer, mA and V – 2 adjustable alarm limits – FM-approved for installation in Div. 2 – 2 relay outputs – Universal AC or DC supply Advanced features • Programmable via detachable display front (4501), process calibration, relay simulation, password protection, error diagnostics and selection of help text in several languages. Connections Application • Process control with 2 pairs of potential-free relay contacts which can be configured to suit any application. • Trip amplifier with window function defined by a high and a low setpoint. The relay changes state outside the window. • Relay latch function, where the relay is activated and can only be reset manually. • Sophisticated sensor error surveillance, where one relay holds the state immediately prior to the sensor error, while allowing the process to continue. The other relay can be set for sensor error alarm so that the defect sensor can be replaced immediately. Technical characteristics • When 4131 is used with the 4501 display / programming front, all operational parameters can be modified to suit any application. As the 4131 is designed with electronic hardware switches, it is not necessary to open the device for setting of DIP-switches. • A green front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay. • Continuous check of vital stored data for safety reasons. • 3-port 2.3 kVAC galvanic isolation. This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability Environmental Conditions Specifications range....................................... Calibration temperature................................. Relative humidity............................................ Protection degree........................................... -20°C to +60°C 20...28°C < 95% RH (non-cond.) IP20 Mechanical specifications Dimensions (HxWxD)..................................... Dimensions (HxWxD) w/ 4501 / 4511............................................................. Weight approx................................................ Weight incl. 4501 / 4511 (approx.)................. Wire size........................................................ Screw terminal torque.................................... 109 x 23.5 x 104 mm 109 x 23.5 x 116 / 131 mm 170 g 185 g / 270 g 1 x 2.5 mm2 stranded wire 0.5 Nm Common specifications Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC Fuse............................................................... 400 mA SB / 250 VAC Max. power consumption............................... ≤ 2.0 W Isolation voltage, test / working........................................................... 2.3 kVAC / 250 VAC Communications interface............................. Programming front 4501 Communications interface............................. Modbus communication enabler 4511 Signal / noise ratio......................................... Min. 60 dB (0...100 kHz) Response time (0...90%, 100...10%): Temperature input.......................................... ≤ 1 s Response time (0...90%, 100...10%): mA / V input.................................................... ≤ 400 ms Accuracy........................................................ Better than 0.1% of selected range Auxiliary supplies: 2-wire supply (terminal 44...43)................................ 25...16 VDC / 0...20 mA EMC immunity influence................................ < ±0.5% of span Extended EMC immunity: NAMUR NE 21, A criterion, burst................................. < ±1% of span Current input: Measurement range.............................................................. 0...20 mA Current input: Programmable measurement ranges..................................... 0...20 and 4...20 mA Input resistance, current input............................................................... Nom. 20 Ω + PTC 50 Ω Voltage input: Measurement range.............................................................. 0...12 VDC Programmable measurement ranges, VDC................................................................ 0/0.2...1, 0/1...5, 0/2...10 VDC Input resistance, voltage input............................................................... Nom. 10 MΩ Output specifications Relay output: Relay functions........................ Setpoint, Window, Sensor error, Latch, Power and Off Hysteresis...................................................... 0...100% ON and OFF delay......................................... 0...3600 s Max. voltage................................................... 250 VRMS Max. current................................................... 2 AAC or 1 ADC Max. AC power.............................................. 500 VA Sensor error reaction..................................... Break / Make / Hold *of span.......................................................... = of the currently selected measurement range Approvals EMC............................................................... EN 61326-1 LVD................................................................ EN 61010-1 FM.................................................................. 3025177 UL................................................................... UL 508 GOST R......................................................... Yes DNV Marine.................................................... Stand. f. Certific. No. 2.4 Input specifications 4131-042214 RTD input....................................................... Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100 RTD input....................................................... Linear resistance RTD input....................................................... Potentiometer Cable resistance per wire (max.), RTD.................................................... 50 Ω Sensor current, RTD...................................... Nom. 0.2 mA Effect of sensor cable resistance (3-/4-wire), RTD............................................. < 0.002 Ω / Ω Sensor error detection, RTD.......................... Yes Short circuit detection, RTD........................... < 15 Ω TC input: Thermocouple type......................... B, E, J, K, L, N, R, S, T, U, W3, W5, LR Cold junction compensation (CJC) via ext. sensor in connector 5910.............................................. 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C CJC via internally mounted sensor............................................................ ±(2.0°C + 0.4°C * Δt) Δt =................................................................. Internal temperature-ambient temperature Sensor error detection, TC............................. Yes Sensor error current: When detecting / else............................................... Nom. 2 μA / 0 μA
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement