Rx35X Installation Guide Multi Protocol Auxiliary Relay Receiver


Add to my manuals
16 Pages

advertisement

Rx35X  Installation Guide Multi Protocol Auxiliary Relay Receiver | Manualzz

Installation Guide

Rx35X

Multi Protocol Auxiliary Relay Receiver

Building Block Video Ltd www.bbvcctv.com

17 Apex Park, Diplocks Way, Hailsham, East Sussex, BN27 3JU,UK

Tel: +44 (0) 1323 842727 Support: +44 (0) 1323 444600

Important – Before you install

Introduction

Unpacking

Different build options

Technical specification

Installation Instructions

PCB Connections

PCB Connections with Wiper connections

Connection table

Protocol and Address Selection

Protocol Table

Address selection

Status LEDs

Launch amplifier

Self test

Random pan

Retrofitting

Installation Instructions for PCB receivers

Contents

14

14

14

11

12

7

8

9

10

13

13

15

4

5

5

5

6

Fig 1. Build options

Fig 2. Technical Specification

Fig 3. PCB Connections

Fig 4. PCB Connections with additional Wiper connections

Fig 5. Connection Table

Fig 6.Protocol Table

Fig 6a. Address Table

9

7

8

6

11

12

Fig 7. Launch Amplifier 13

14 Fig 8. Self test sequence

Fig 9. Metalwork drilling details 15

5

Rx35X manual V3 July 2015 Page 3

IMPORTANT

Before you install:

Please read the following points before servicing or installing any telemetry receiver:

Pre-installation checks - It is recommended that the unit be bench tested prior to installation on the site.

Safety during installation or servicing - Particular care should be taken to isolate the pan/tilt head in order to prevent operation while engineering work is being carried out. In addition any ladder or other means of working on the receiver MUST NOT rest on the pan/tilt head as it is possible for the head to move when not expected.

Safety check - Upon completion of any service or repairs to the unit, safety checks should be performed to ensure that the unit is in proper operating condition.

Coax grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded.

Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed.

WARNING - TO PREVENT DANGER OF FIRE OR SHOCK, DO NOT EXPOSE THE INTERNAL

COMPONENTS OF THIS EQUIPMENT TO RAIN OR MOISTURE.

Damage requiring service - Servicing by qualified personnel should be carried out under the following conditions:

(a) When the power supply cord or plug is damaged;

(b) If liquid has been spilled or objects have fallen into the unit;

(c) If the internal electronics of the unit have been exposed to rain or water;

(d) If the unit does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, as improper adjustment of other controls may result in damage;

(e) If the unit has been dropped or the enclosure is damaged;

(f) If the unit exhibits a distinct change in performance. This indicates a need for service.

Replacement parts - If replacement parts are required, ensure that only replacement parts recommended by the product manufacturer are used.

SAFETY PRECAUTIONS

All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed and servicing should be referred to qualified service personnel.

Rx35X manual V3 July 2015 Page 4

RX35X - Introduction

The RX35X is a telemetry receiver with ac pan and tilt outputs; it allows entry level control of ac pan/ tilt & zoom/ focus with a wiper auxiliary output.

The unit is suitable for 230V mains operation. As a factory fitted option, the receiver can be supplied to operate from 24V ac or 110V ac. This option must be specified at time of order.

Telemetry

The RX35X is supports addresses 1 -32 with the following Protocols:

BBV422 @ 9600, N, 8, 1

PELCO P @ 4800, N, 8, 1

PELCO P @ 9600, N, 8, 1

PELCO D @ 2400, N, 8, 1

PELCO D @ 9600, N, 8, 1

SENSORMATIC RS422 @ 4800, N, 8, 2 *

MOLYNX D-TYPE TELEMETRY @ 9600, E, 8, 1

VISTA RS485 @ 9600, N, 8, 1

VISTA RS485 @ 19200, N, 8, 1

VCL RS485 @ 9600, N, 8, 1

VICON RS422 @ 4800, N, 8, 1 *

VICON RS422 @ 9600, N, 8, 1 *

VICON RS422 @ 19200, N, 8, 1 *

* NOTE this is a 2 wire receiver. This means it will not give responses back to the control system.

Unpacking

Inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Unpack the receiver carefully and check that all items are included:

Fig 1. The different build options.

Part number Description

Rx35X

PCB

Weather proof box

IEC connector

Manual

Warranty card

Rx35X

Rx35X/PCB

Rx35X/24

Telemetry receiver 230V ac input 230V ac output

Telemetry receiver 230V ac input 230V ac output PCB only

Telemetry receiver 230V ac input 24V ac output

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Rx35X/24/24

Rx35X/24/24/PCB

Rx35X/110/110

Rx35X/110/110/PCB

Rx35X/110/24

Telemetry receiver 24V ac input 24V ac output

Telemetry receiver 24V ac input 24V ac output PCB only

Telemetry receiver 110V ac input 110V ac output

Telemetry receiver 110V ac input 110V ac output PCB only

Telemetry receiver 110V ac input 24V ac output

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Rx35X manual V3 July 2015 Page 5

Fig 2. Technical Specification

Power requirements

Load

230V 50/60Hz (options are available for 24V ac or 110V ac supply)

5A at 230V max

Standby Current

F2: Auxiliary output fuse

Outputs

6VA max

Supply

230

230

110

110

24

Output

230

24

110

24

24

5 single pole changeover relays (snubbed):

1. Left motor

2. Right motor

Fuse F2

5A T

315mA T

5A T

630mA T

5A T

Telemetry

Auto iris output

Video input

Video output

Video Cabling

Telemetry Cabling

Dimensions

Depth

3. Up motor

4. Down motor

5. Wiper auxiliary output

6. Zoom drive

7. Focus drive

8. Iris override

RS485 or RS422 Simplex

Returns to original setting 15 seconds after key release

Level programmable from keypad

To drive override input for Cosmicar, or Seiko style lens

1V p-p 75R terminated input via BNC socket

1V – 4V p-p 75R impedance via BNC socket

RG59 or CT125 for more information see Cable factors data sheets

Belden 8723

RX35X PCB

100mm

RX35X Boxed

190mm

Width

Height

Weight

190mm

38mm

0.4kg

380mm

130mm

2.5kg

Rx35X manual V3 July 2015 Page 6

Fig 3. Rx35X INSTALLATION INSTRUCTIONS PCB Connections

SW8(on/off) Start Self Test -

LEFT, RIGHT, UP, DOWN, AUTOPAN, LAMPS, WIPE, WASH, ZOOM IN, OUT, FOCUS NEAR, FAR, IRIS OPEN, CLOSE

ON ON

1 2 3 4 5 6 7 8

SW 1 - 5 address

See table on Page 9

SW 6 Iris type off = Seiko on = Cosmicar

SW 7 Lens voltage off = 12v on = 6v

SW 8 Self test

S

1 2 3 4 5 6 7 8

metry and sync ok.

Telemetry

- No sync from camera

ERROR

ON - Telemetry error.

Rx35X

SW 1 - 5 Address

SW3

4 BINARY

ADDRESS

3

4

1

2

5

6

7

8

SW1

1

OFF

ON

OFF

ON

OFF

ON

OFF

ON

SW2

2

OFF

OFF

ON

ON

OFF

OFF

ON

ON

9 OFF OFF

SW 6 Iris type off = Seiko on = Cosmicar

OFF

OFF

OFF

OFF

ON

ON

ON

ON

OFF

SW4

8

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

SW5

16

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Cable compensation.

Lift:

Clockwise to increase

HF content.

Gain:

Clockwise to increase overall video level.

Gain and Lift are factory preset for 500M of RG59 cable.

ERROR

CABLE

SW 7 Lens voltage off = 12v on = 6v

SW 8 Self test

Supply

230

230

110

110

24

Out put fuse rati ng

Output

230

24

Fuse

5A T

315mA T

110

24

24

5A T

630mA T

5A T

WARNING HAZARDOUS VOLTAGE

ISOLATE AND MAKE SURE THIS UNIT IS SECURE FROM ANY AND ALL HAZARDOUS

VOLTAGES BEFORE STARTING WORK OR REMOVING THIS LABEL

LIFT

GAIN

Video In

From Camera

Video Out

To Transmitter

Building Block Video Ltd

17 Apex Park Hailsham, East Sussex, UK. BN27 3JF. Tel: +44 (0)1323 842727 Fax: +44 (0)1323 842728

Tech Support: +44 (0)1323 444600 Web site for manuals / data sheets / application notes etc. www.bbvcctv.com

F Z

1 2 3 4 5 6 7 8 9

1

0

1

1

93004 iss.7

J4

110Vac and

24Vac supply options are available.

This must be specified at order time.

230Vac as standard.

1 2 3 4 5 6 7

1

2

TPA TPB IO COM FC COM ZM

FOCU C

O

GROUND

RS485

S

M

M

O

N

ZOO

M

SERIAL

TELEMETRY F Z

AUTO IRIS

IRIS OVERRIDE

LAMPS D U R L UNSWITCHED

F8

NEUTR

A

L

E

A

R

TH

L

IV

E

NEUTR

A

L

E

A

R

TH

D

O

W

N

UP

NEUTR

E

A

R

A

L

TH

LIV

E

RIGHT

L

E

FT

UNSWITCHED

WIPER

OUTPUT.

CAMERA

SUPPLY

ETC.

PAN/TILT HEAD

Output fuse rating

Supply Output Fuse

230 230 5A T

230

110

110

24

24

110

24

24

315mA T

5A T

630mA T

5A T

BBV 24VAC mk.3 option plugs into this socket for 24Vac output.

ALL J6 outputs are at mains or

24Vac when 24V option fitted

Including unswitched outputs.

Rx35X manual V3 July 2015 Page 7

Fig 4.

INSTALLATION INSTRUCTIONS PCB Connections with additional Wiper connections

SW8(on/off) Start Self Test - LEFT, RIGHT, UP, DOWN, AUTOPAN, LAMPS, WIPE, WASH, ZOOM IN, OUT, FOCUS NEAR, FAR, IRIS OPEN, CLOSE

ON

1 2 3 4 5 6 7 8

SW 1 - 5 address

See table on Page 9

Building Block Video Ltd

17 Apex Park Hailsham, East Sussex, UK. BN27 3JF. Tel: +44 (0)1323 842727 Fax: +44 (0)1323 842728

Tech Support: +44 (0)1323 444600 Web site for manuals / data sheets / application notes etc. www.bbvcctv.com

F

ERROR

CABLE

SW 7 Lens voltage off = 12v on = 6v

Supply

230

230

110

110

24

Output fuse rating

Output

230

24

110

24

24

Fuse

5A T

315mA T

5A T

630mA T

5A T SW 8 Self test

WARNING HAZARDOUS VOLTAGE

ISOLATE AND MAKE SURE THIS UNIT IS SECURE FROM ANY AND ALL HAZARDOUS

VOLTAGES BEFORE STARTING WORK OR REMOVING THIS LABEL

Z

93004 iss.7

GAIN

J4

110Vac and

24Vac supply options are available.

This must be specified at order time.

230Vac as standard.

SW 6 Iris type off = Seiko on = Cosmicar

SW 7 Lens voltage off = 12v on = 6v

SW 8 Self test

1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9

1

0

1

1

1

2

TPA TPB IO COM FC COM ZM

FOCU C

RS485

GROUND

S

O

M

M

O

N

ZOO

M

SERIAL

TELEMETRY F Z

WIPER D U R L UNSWITCHED

NEUTR

A

L

E

A

R

TH

S

W

ITCH

E

D

L

IV

E

NEUTR

A

L

E

A

R

TH

D

O

W

N

UP

NEUTR

E

A

A

L

R

LIV

E

TH

RIGHT

L

E

FT

F8 Output fuse rating

Supply Output Fuse

230

230

110

110

24

230

24

110

24

24

5A T

315mA T

5A T

630mA T

5A T

AUTO IRIS

IRIS OVERRIDE WIPER

UNSWITCHED

OUTPUT.

CAMERA

SUPPLY

ETC.

PAN/TILT HEAD

PARK / UNSWITCHED LIVE

WIPE

NEUTRAL

EARTH

WIPER

CONNECTIONS

Rx35X manual V3 July 2015 Page 8

All connections to the PCB must be via terminal blocks or by plug and socket. These connections are:

Power, video in, video out, and pan or tilt auxiliary outputs. (See Connection diagrams on page 7 & 8)

Connecting power

The input power supply connector is J4. This is a Standard IEC connector.

Connectors

BBV have adopted a simple to use method of attaching cables to PCBs quickly and easily. The correct method of attachment is as follows:

1. Use only cable between 0.08 and 2.5 mm²

2. Strip the cable to a length of 5 to 6 mm (0.23 in)

3. Press down the relevant terminal block lever with a screwdriver

4. Insert wire

5. Remove screwdriver

Detachment of wires is the reverse procedure of steps 3 to 5, ensuring that power

is disconnected before starting.

Fig 5. Connection Table

Colour of cable

(this is only a guide)

Function

Main Cable (18 Core)

Brown Camera Power Live

Connection

J6-12

Green

Blue

Red

Yellow

Black

Camera Power Ground

Camera Power Neutral

Pan Left

Pan Right

Tilt Up

J6-11

J6-10

J6-9

J6-8

J6-7

White Tilt Down J6-6

Green/Red

Turquoise

Red/Blue

Yellow/Red

White/Red

Orange

Motor Head Earth

Motor Head Neutral

Wiper Function Live

Wiper Function Earth

Wiper Function Neutral

Lens Drive Zoom Motor

J6-5

J6-4

J6-3

J6-2

J6-1

J3-7

Grey

Pink

Violet

Twisted Pair Cable

Twisted Pair Cable

Lens Drive Motor Return (Common Ground)

Lens Drive Focus Motor

Auto Iris Override Ground

Auto Iris Override

Data B TELEMETRY

Data A TELEMETRY

J3-6

J3-5

J3-4

J3-3

J3-2

J3-1

Rx35X manual V3 July 2015 Page 9

Protocol & Address selection

The Rx35X is a multi protocol Receiver. To select the correct protocol and address is a simple 4 stage process:

Stage 1

Power the unit down & wait 5 seconds then turn on switch 8 (this puts the board into protocol mode)

ON

1 2 3 4 5 6 7 8

Stage 2

With the use of the dip switches select the protocol (see fig 6) and power up the unit.

ON

SW1 on = BBV422

1 2 3 4 5 6 7 8

Stage 3

Turn off Switch 8. The error light will flash to correspond with the number in the Protocol table. For example on an Rx35X that has been set to BBV RS422 telemetry, the error LED will flash once. (If the number is over

10, the error LED will flash once, then pause, and then flash again – for example the error LED on an Rx35X set to Vicon 9600 N 8 1 will flash once, pause, then flash twice to indicate 12.)

ON

SW1 on = BBV422

1 2 3 4 5 6 7 8

Your protocol has now been selected.

Stage 4

Use the same dipswitch to set the camera address. Check the Address Table (Fig.6a) for the dipswitch configuration, and set the dipswitches accordingly:

ON

SW2 on = Camera Address 3 (see Fig 6A)

1 2 3 4 5 6 7 8

Rx35X manual V3 July 2015 Page 10

Fig 6. Protocol Table SW1:

ON

0 = TEST MODE

(NO Protocol support)

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

1 = BBV422

(9600 N,8,1)

ON ON

1 2 3 4 5 6 7 8

ON

2 = PELCO P

(4800 N,8,1)

4 = PELCO D

(2400 N,8,1)

1 2 3 4 5 6 7 8

ON

6 = SENSORMATIC

(4800 N,8,2)

1 2 3 4 5 6 7 8

ON

8 = VISTA

(9600 N,8,1)

1 2 3 4 5 6 7 8

ON

10 = VCL

(9600 N,8,1)

1 2 3 4 5 6 7 8

ON

12 = VICON

(9600 N,8,1)

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

3 = PELCO P

(9600 N,8,1)

5 = PELCO D

(9600 N,8,1)

7 = MOLYNX

(9600 E,8,1)

9 = VISTA

(19200 N,8,1)

11 = VICON

(4800 N,8,1)

13 = VICON

(19200 N,8,1)

Rx35X manual V3 July 2015 Page 11

Fig 6a. Address Table SW1

NOTE that camera address 1 is Binary address 0.

SW1 SW2 SW3 SW4 SW5

1 2 4 8 16

Address 1 OFF

Address 2 ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Address 3 OFF

Address 4 ON

Address 5 OFF

Address 6 ON

Address 7

Address 8

Address 9

Address 10

Address 15

Address 16

Address 17

Address 18

OFF

ON

OFF

ON

Address 11 OFF

Address 12 ON

Address 13 OFF

Address 14 ON

OFF

ON

OFF

ON

Address 19 OFF

Address 20 ON

Address 21 OFF

Address 22 ON

Address 23 OFF

Address 24 ON

Address 25 OFF

Address 26 ON

Address 27 OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

ON

ON

ON

ON

OFF

OFF

OFF

OFF

ON

ON

ON

ON

OFF

OFF

OFF

OFF

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

OFF

OFF

ON

ON

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

SW6 Iris Type

OFF =Seiko

ON = Cosmicar

SW7 Lens Voltage

OFF = 12V

ON = 6V

SW8 Self Test

ON then OFF Starts self test

Address 28 ON

Address 29 OFF

Address 30 ON

Address 31 OFF

Address 32 ON

Rx35X manual V3 July 2015 Page 12

Status LEDS

Error and Cable LEDS are mounted on board to give simple system status information. Their functions are as follows:

Cable LED

Flashing once a second = Heartbeat (Receiver is on but not receiving any valued data)

Fast Flashing = Receiving valued data for the address.

What to do if your cable LED is OFF:

Check you have connected power to the Rx35X. If power is connected and the cable LED is still not on, please contact BBV technical support team (01323 444600) or [email protected].

Error LED - not used

Note: As all BBV equipment is designed to auto tune and compensate for any discrepancies in the transmitter signal, there are no further adjustments that need to be made.

LAUNCH AMPLIFIER

There are two variable controls, Lift and Gain, situated close to the BNC connector J1. The purpose of each control is:

Lift: boosts the high frequency signal. Turn clockwise to increase HF content.

Gain: adjusts the gain of the video signal. Turn clockwise to increase overall video level.

These are pre-adjusted for a cable distance of 500m, and are adjustable to compensate for video detail or signal losses if and when longer or shorter cable lengths are used to connect the monitor to the receiver. The correct sync level is 300mV.

Fig 7.

Video In

From Camera

LIFT

Video Out

To Transmitter

GAIN

ATTENTION: Ensure that the cable is terminated at the monitor end ONLY

Rx35X manual V3 July 2015 Page 13

SELF TEST

The diagnostic and status check is activated either locally from the PCB or via the BBV keypad.

To activate the self test locally, turn SW8 ON momentarily. This activates each camera function for two seconds in turn.

The Cable LED should be OFF; (ie not flashing or continuously.)

Fig 8. Self test sequence

Order of function test: Camera moves left

Camera moves right

Camera moves up

Camera moves down

Wiper function

Lens zoom in

Lens zoom out

Lens focus near

Lens focus far

Auto iris open

Auto iris close

Diagnostic check complete, unit resets and continues normal operation.

Random Pan

The Random Pan feature allows the receiver to drive the head in a left or right direction at random for a random time. The head will pause for a random time between movements. Over a period of time, the head will move between the right and left end stops. This feature does not require an autopan card to be fitted to the head.

How to start Random Pan:

Issue a PATROL command from the telemetry controller. The key strokes required will vary depending upon the model of controller. Please refer to the controller handbook for details.

Retrofitting

When using 24Vac heads, if the receiver is operating from an 110Vac or 230Vac supply either a 230/24Vac kit or 110/24Vac kit is used. The jumper fitted between J4 & J5 is removed and the plugs supplied with the kit are connected in its place. Fuse F2 is changed to the value shown in the Technical Specification.

Rx35X manual V3 July 2015 Page 14

INSTALLATION INSTRUCTIONS FOR PCB BASED RECEIVERS

WARNING: THIS EQUIPMENT MUST BE EARTHED.

1. When mounting BBV receivers on metalwork, it is essential to maintain correct earthing.

2. CORRECT CLEARANCE. Metal spacers M3 x 10mm long should be used to mount the PCB on the metalwork. These should be earthed to ensure optimum performance. Spacers of the correct length will ensure that minimum air gaps are exceeded.

3. Use all of the mounting points to ensure adequate support with minimum flexing when connections are made to the unit. See diagram.

4. In case of queries, technical assistance is available on +44 (0)1323 444600 or [email protected].

Fig 9.

Metalwork Drilling Holes

1 10

Output Fuse 5A

Rx35X manual V3 July 2015

95

Page 15

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement