IP INTERCOM

DIRECT SELECT UNIT

INSTALLATION MANUAL

N-8000DI

Thank you for purchasing TOA's IP Intercom Direct select unit.

Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

2

TABLE OF CONTENTS

1. SAFETY PRECAUTIONS

............................................................................... 3

2. GENERAL DESCRIPTION

............................................................................. 4

3. FEATURES

.......................................................................................................... 4

4. NOMENCLATURE AND FUNCTIONS

Front ......................................................................................................................... 5

Rear .......................................................................................................................... 5

5. INSTALLATION

5.1. Equipment Rack Mounting

5.1.1. Setting space ........................................................................................... 6

5.1.2. Caution when installing the unit ............................................................... 6

5.1.3. Mounting on the rack ............................................................................... 7

5.2. Desk-Top Installation ......................................................................................... 7

5.3. Wall Mounting .................................................................................................... 8

6. WIRING

6.1. Connection Diagram .......................................................................................... 9

6.2. Type of Cable ................................................................................................... 11

6.3. Removable terminal plug connection ............................................................... 11

7. ACCESSORIES

................................................................................................. 12

8. OPTIONAL PRODUCT

.................................................................................... 12

1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.

• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety.

• After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions

Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.

WARNING

CAUTION

Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.

WARNING

When Installing the Unit

• Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.

• Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.

• Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock.

• Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down and causing personal injury and/or property damage.

• Install the unit only in a location that can structurally support the weight of the unit and the mounting bracket. Doing otherwise may result in the unit falling down and causing personal injury and/or property damage.

When the Unit is in Use

• Should the following irregularity be found during use, immediately disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock.

· If you detect smoke or a strange smell coming from the unit

· If water or any metallic object gets into the unit

· If the power supply cord is damaged (exposure of the core, disconnection, etc.)

· If it is malfunctioning (no tone sounds.)

• To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to qualified service personnel.

• Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock.

• Do not touch a plug during thunder and lightning, as this may result in electric shock.

CAUTION

When Installing the Unit

• Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.

• When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.

• Be sure to follow the instructions below when rackmounting the unit. Failure to do so may cause a fire or personal injury.

· Install the equipment rack on a stable, hard floor.

Fix it with anchor bolts or take other arrangements to prevent it from falling down.

3

4

· When connecting the unit's power cord to an AC outlet, use the AC outlet with current capacity allowable to the unit.

· The supplied rack-mounting screws can be used for the TOA equipment rack only. Do not use them for other racks.

When the Unit is in Use

• Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage.

• Do not stand or sit on, nor hang down from the unit as this may cause it to fall down or drop, resulting in personal injury and/or property damage.

2. GENERAL DESCRIPTION

TOA's N-8000DI is Direct select unit used for the N-8000 Series Packet Intercom System (IP network compatible intercom) employing packet audio technology* 1 .

It is equipped with each 32 contact input and outputs, and the indicators on the front panel indicate the output statuses.

Connecting the unit to the LAN permits the calling station display, external equipment control, and direct selection function to be realized.

* 1 Technology related to audio transmission over a network.

Warning

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

3. FEATURES

• Exchanges, IP stations and various kinds of interface units can be distributed over a data communications network.

• Can be connected to an existing local area network (LAN) or wide-area network (WAN).

• The dedicated software program enables centralized control with a personal computer.

• System maintenance (verifying operation log and Line supervision) can also be performed with a personal computer and Internet browser.

• The unit can interlock with an electronic lock system or CCTV surveillance system by way of contact input/output control function.

4. NOMENCLATURE AND FUNCTIONS

[Front]

1 2 3 4 5 6

1. Reset key [RESET]

Pressing this key reactivates this unit.

2. LNK/ACT indicator [LNK/ACT] (Green)

Lights when connected to a network, and flashes while transmitting or receiving data.

3. Status indicator [STATUS] (Red)

Continuously lights while data is written to an internal storage medium (FlashMemory).

Flashes if there is a failure.

4. Power indicator [POWER] (Green)

Lights when power is supplied to the unit.

5. MAC address

This is the address* 1 used by the unit. Since the relationship of each exchange location to its MAC address is established when setting the network attributes, keep track of this relationship for later use.

* 1 The inherent address assigned to each network component, expressed in 12-digit hexadecimal notation.

6. Channel status indicator [CHANNEL] (Green)

Lights when the contact output is ON.

[Rear]

7 8 9 10

11 12

7. Cord clamp

Pass the power cord through this clamp to ensure that the plug does not pull out when the unit is mounted to a wall. (Refer to p. 8.)

8. Functional earth terminal [SIGNAL GND]

Ground this terminal.

Note: This terminal is not for protective earth.

9. AC inlet

Connect the supplied power cord.

Note

If there is a danger of lightning strikes, insert an appropriate surge arrester into the power line.

10. Contact input terminals [CONTACT INPUT]

No-voltage make contact inputs.

Short-circuit current: under 5 mA, Open-circuit voltage: 24 V

Connect using a removable terminal plug.

(Refer to p. 11.)

11. Contact output terminals

[CONTACT OUTPUT]

Relay contact outputs.

Withstand voltage: 24 V DC, Control current: 2 –

500 mA

Connect using a removable terminal plug.

(Refer to p. 11.)

12. Network connection terminal [10/100M]

Connects to a 10BASE-T- or 100BASE-TXcompatible network. (Ethernet RJ-45 jack)

5

6

5. INSTALLATION

The N-8000DI can be installed in any of three ways: (1) equipment rack mounting, (2) wall mounting, and (3) desk-top installation.

5.1. Equipment Rack Mounting

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature

(Tma) specified by the manufacturer.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.

Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."

The N-8000DI can be mounted on the CR -273 or CR -413 or standard EIA 19" Equipment rack.

For the CR -273 and CR -413 Equipment rack assembly, read the installation manual supplied with the rack.

Note

When installing the N-8000DI, lay the equipment rack down face-up to do installation work safely.

5.1.1. Setting space

For maintenance works, allow much space between the wall and Equipment rack.

N-8000DI

50 cm

50 cm

50 cm

1 m

5.1.2. Caution when installing the unit

Do not stack up 3 units or more. If 2 or more units are mounted in the Equipment rack, be sure to mount the perforated panel of 1 U size (PF-013B) or more above and below every 2 units.

N-8000DI

Equipment rack

Perforated panel

5.1.3. Mounting on the rack

N-8000DI

Tapping screw 3 x 8

(supplied with the N-8000DI) Rack mounting bracket

(supplied with the N-8000DI)

1

Step 1. Install the rack-mounting bracket to the

N-8000DI.

Step 2. Mount the N-8000DI on the Equipment rack.

2

Rack mounting screw 5 x 12 with plain washer

(supplied with the N-8000DI)

5.2. Desk-Top Installation

When installing the N-8000DI on a desk, secure the supplied plastic feet to the unit's bottom using the supplied machine screws.

Machine screw M3 x 8

(supplied with the N-8000DI)

Plastic foot

(supplied with the N-8000DI)

N-8000DI

7

5.3. Wall Mounting

Step 1. The N-8000DI can be mounted on a wall using an optional YC-850 Wall-mounting bracket .

Install the YC-850 to the N-8000DI.

Wall mounting bracket

(YC-850)

Machine screw M3 x 6

(supplied with the YC-850)

N-8000DI

8

Step 2. Mount the N-8000DI on the wall.

Notes

• Use appropriate screws for the construction of wall.

• Wood screws 3.5 x 20 are supplied with the YC-850.

• The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible.

Protect against disconnection

(Power supply plug)

Unlock cord clamp and run the power supply cord through it.

Note

Keep the cable length between a power supply plug and cord clamp as short as possible.

Wall surface

Power supply cord

Cord clamp

Wood screw 3.5 x 20

(supplied with the YC-850)

6. WIRING

6.1. Connection Diagram

N-8000DI Direct select unit

1

Be sure to ground.

To AC mains or a UPS

(Uninterruptible power supply system)*.

Note

If there is a danger of lightning strikes, insert an appropriate surge arrester into the power line.

* 1

2

Contact input signals

2

Contact input signals

2

Contact input signals

2

Contact input signals

* 1 10P removable terminal plug

(supplied with the N-8000DI)

[General description of connection]

For cables, refer to p. 11.

1. Power supply connection

Connect the supplied power supply cord to AC

Mains or a UPS (Uninterruptible power supply).

About power supply cord handling

The supplied power supply cord is designed for exclusive use with the N-8000DI.

Use the supplied power supply cord only with the

N-8000DI.

2. Contact input terminal connection

(Refer to p. 11, Terminal plug connection.)

[Specification of no-voltage make contact input]

Short-circuit current: 5 mA

Open-circuit voltage: 24 V

* Select an appropriate UPS taking into consideration the total power consumption of all system components and the required backup time, and also the requirement that the UPS should employ the on-line power system.

Reference

Direct select unit: 16 W (rated) for CE version, 16W (rated) for CU version

8-Port 10M/100M Switching Hub: 10W (Differs depending on products.)

Note

Please keep the terminal plug of the attachment not used importantly in preparation for increasing the system.

9

10

N-8000DI Direct select unit

3

Contact output signals

3

Contact output signals

4

RJ-45 connector

To network

16P removable terminal plug

(supplied with the N-8000DI)

3

Contact output signals

3

Contact output signals

3. Contact output terminal connection

Contact output terminals have no polarity.

(Refer to p. 11, Terminal plug connection.)

[Specification of relay contact output]

Withstand voltage: 24 V DC

Control current: 2 mA – 500 mA

4. Network connection

Can be connected to a network of 10BASE-

T/100BASE-TX in auto-sensing.

Use a straight through cable of UTP category 5 or more for this connection.

6.2. Type of Cable

The types of cables are to be determined according to the following conditions.

• UTP category 5 Straight through cables with RJ45 connector are to be used for connecting to IP network.

• The number of cables pairs laid should be determined considering the possibility of future expansion of the system.

• Outdoor wires should be used where wiring passes through inaccessible areas such as ceilings or under floors where the maintenance is not performed. Indoor wires may also be used, however, in case where there is no risk of deterioration due to exposure to heat, etc.

Note

Specifications related to junction are as follows.

Removable terminal plug (N-8000DI Control I/O terminal)

Conductor diameter: ø 0.5 – 2 mm (AWG12 – 24), Solid wire/Stranded wire

6.4. Removable terminal plug connection

Step 1. Strip a cable jacket of approx. 7 mm to expose inner cable.

7 mm

For cables, refer to p. 11, Type of Cable.

Note

Do not solder plate on exposed inner cables when using a stranded wire.

Step 2. Loosen the terminal screws and insert the cables.

Step 3. Tighten the terminal screws securely.

Notes

• Tug lightly on the cable to be sure that it does not pull free. If the cable pulls free, loosen the terminal screw again and reconnect from Step 2.

• Use the screwdriver appropriate to the screws tightened into the terminal plug.

Step 4. Insert the wired terminal plug into the terminal block of the N-8000DI.

N-8000DI rear panel

Tighten

3

4

2

Removable terminal block

Removable terminal plug

(accessory)

11

7. ACCESSORIES

AC power cord (2 m) .............................................. 1

CD* (for PC setting, maintenance use) .................. 1

Removable terminal plug (10 pins) ........................ 4

Removable terminal plug (16 pins) ........................ 4

Plastic foot .............................................................. 4

Machine screw M3 x 8 ........................................... 4

Rack mounting bracket .......................................... 2

Tapping screw 3 x 8 ............................................... 8

Rack mounting screw with plain washer ................ 4

* Contains the N-8000 setting software program and the N-8000 series instruction manual. The Setup

Launcher is automatically started when the supplied CD-ROM is inserted into the PC's drive.

Note

If your PC's CD drive is not compatible with the AutoRun function, the setup guide is not automatically started even when the CD is inserted. Use either "Explorer" or "My Computer" to execute the following files, or use [Start Run] in the Task Bar and enter the following command.

<Drive where CD is placed> \index.html

For example, when placing the CD in the "d" drive, d:\index.html

8. OPTIONAL PRODUCT

Wall mounting bracket: YC-850

Version update information

• Download our TOA Products Data, web site (http://www.toa-products.com/international/) to get the up-to-date version for N-8000 software, firmware, and Instruction manuals.

• The software version number can be confirmed using the Help menu.

• The current firmware version can be confirmed on the system management screen displayed when the browser establishes the connection to the Exchange.

• The instruction manual version number can be confirmed by checking the preparation date (month and year) shown at the lower right corner of the last page.

Example: Prepared in November 2004: 200411

Traceability Information for Europe (EMC directive 2004/108/EC)

Manufacturer:

TOA Corporation

7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo,

Japan

Authorized representative:

TOA Electronics Europe GmbH

Suederstrasse 282, 20537 Hamburg,

Germany

URL: http://www.toa.jp/

133-21-934-4A

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals