P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
Applications
Distribution Equipment
• The P Series PowerPlex panelboard provides indoor and
outdoor protection and control of electrical circuits in hazardous
environments such as:
— Petroleum plants
— Chemical plants
— Refineries
— Other process facilities
• Ideal for placement in wet, corrosive environments or where
flammable gases or vapors are likely to be present.
• Suitable for use on lighting, heat trace and power circuits.
• No external conduit or cable seals required thus making
installations faster, easier, and less costly.
• Limitless flexibility through horizontal and vertical coupling
options.
• The PowerPlex panelboard features a ground-breaking
design that uses individual breaker housings to minimize the
downtime and costs associated with servicing circuit breakers
in hazardous locations.
• The lighter weight panelboard enclosure can be quickly opened
in the field for easier servicing.
• Supplied as standard:
— Bottom entries with brass earth plate
— Pre-drilled supplied with non Ex certified temporary plastic
plugs
— Standard hard wired, copper cables
— Color coded wiring for phases; neutral (blue) and ground
(yellow/green)
— Internal actuators
— Internal wiring duct
— Phenolic nameplate (specify legend)
• Optional gland plate at the bottom of enclosure can be easily
field punched or drilled for cable or conduit entries. See options.
• 1 circuit to 72 circuit panelboard configurations are standard,
with or without main breaker.
•Schneider  breakers are supplied as standard, making
replacements readily available.
• PowerPlex breakers accommodate ABB  breakers. For a
custom panelboard designed with ABB breakers, contact your
local sales representative.
• Branch circuit breakers available in 1-, 2- 3- and 4-pole. Current
ratings on branch breakers:
— 1-pole: 120, 240 Volts, 63 Amps maximum.
— 2-, 3- and 4-pole: 240 and 415 Volts, 63 Amps maximum.
• Branch breakers are labeled with numbers:
— Odd numbers for line side
— Even numbers for load side.
— Labeled with inside breaker details
• Main circuit breaker:
— 40 to 250 Amps, 2- , 3- or 4-pole.
• Branch and main breakers can be padlocked in either the “On”
or “Off” position.
• Breaker modules supplied with captive bolts.
•Ground bar provided as standard.
• External ground lug provided as standard.
• 240/415 Volt breaker module 8-pole terminal wire range 2.5
mm2 through 10 mm2 (standard), 16 mm2 with special lug.
• 600 Volt main breaker module 4-pole terminal wire range 16
mm2 through 150 mm2.
• Ambient temperature ratings:
— Standard model: -25 °C to +55 °C (-13 °F to +131 °F).
— Standard model without switching: -40 °C (-40 °F)
Standard Materials
•
•
•
•
Enclosure: fiberglass reinforced polyester (FRP)
Hardware: stainless steel
Bus bar: hard drawn copper
Chassis: hot dip galvanized for wall mounting use
Options
Must be listed in alphanumeric sequence at the end of the catalog number.
• Drain, add suffix —D.
• Drain/breather, add suffix —DV.
• Gland plate bottom only, specify suffix —GPP = plastic gland
plate, —GPB = brass gland plate.
• Stainless steel legend plate (specify legend), add suffix —SP.
• Voltmeter, add suffix —VM .
• Ammeter, add suffix —AM .
• Cable glands installed, add suffix —CG; (cable details to be
provided by customer).
• For Ex de IIC, add suffix —IIC.
• Optional frame (structure) for floor mounting, self standing with
and without canopy, contact your local sales representative for
additional information.
ATEX/IECEx Certifications and Compliances
• Type : PowerPlex
— Ambient Temperatures:
– Standard model: -25 °C to +55 °C
 Schneider is a registered trademark of Schneider Electric.
 ABB Asea Brown Boveri Ltd is registered with the commercial register of Zurich, Switzerland.
 Please contact your local sales representative for Voltmeter and Ammeter options.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1069
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Features
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
– Standard model without switching: -40 °C to +55 °C
— Gas, Zones 1 and 2:
– Conforming to ATEX 94/9/EC:
II2G
– Equipment Protection Level: EPL Gb
– Protection: Ex db eb IIB+H2
– T Rating: T5 for Ta ≤ +40 °C and T4 for Ta ≤ +55 °C
— Dusts, Zones 21 and 22:
– Conforming to ATEX:
II2D
– Equipment protection level: EPL Db
– Protection: Ex tb IIIC
– T Rating: 95°C for Ta ≤ +40 °C and 130 °C for Ta ≤ +55 °C
— ATEX Certificate : LCIE 13 ATEX 3083X
— EC Declaration of Conformity : 50304
— IECEx Certificate : IECEx LCIE 13.0073X
— Ingress Protection (solid and liquid) : IP66
— Impact Resistance: IK10
— Ex Standards: EN/IEC 60079-0; 60079-1; 60079-7; 60079-31
— Other Standards: EN/IEC 60529 (IP); 62262 (IK)
1070
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Catalog Numbering Guide 
P
E
Step 1
06
24
2
16
Step 2
Mains Selection
Main Type:
L - Main Lug Only
S - Isolator
Switch 
M - Main Circuit
Breaker
(MCCB)
C
G030
Step 3
Branches Selection
Number of
Poles:
1 - 1-Pole
2 - 2-Poles
3 - 3-Poles
4 - 4-Poles
5 - 1-Pole +
Neutral
___

Step 4
Step 5
1
Suffix for
Other
Options/
Features:
Must be
listed in
alphanumeric
sequence
GFI :
Blank No GFI
G010 - 10mA
G030 - 30mA
G100 - 100mA
G300 - 300mA
(See Options)
# Customized
Panelboard
Panel Material:
P - Fiberglass
Reinforced
Polyester (FRP)
Panel Arrangement:
(See Panel Arrangement
Table on following page for
selection details)
A - 750 x 320 x 150
B - 750 x 640 x 230
C - 1000 x 640 x 230
D - 750 x 960 x 230
E - 1000 x 960 x 230
F - 1250 x 1280 x 230
G - Customized by factory
Incoming Mains
Ampere Rating:
01 - 3 x 40 A
02 - 4 x 40 A
03 - 3 x 50 A
04 - 4 x 50 A
05 - 3 x 63 A
06 - 4 x 63 A
07 - 3 x 80 A
08 - 4 x 80 A
09 - 3 x 100 A
10 - 4 x 100 A
11 - 3 x 125 A
12 - 4 x 125 A
13 - 3 x 160 A
14 - 4 x 160 A
15 - 3 x 200 A
16 - 4 x 200 A
17 - 3 x 250 A
18 - 4 x 250 A
Number of branch
Breakers:
1 through 72
(1-pole up to 72;
2-pole up to 36)
Ampere
Rating:
05 - 0.5 AT
01 - 01 AT
02 - 02 AT
03 - 03 AT
04 - 04 AT
06 - 06 AT
10 - 10 AT
16 - 16 AT
20 - 20 AT
25 - 25 AT
32 - 32 AT
40 - 40 AT
50 - 50 AT
63 - 63 AT
Breaker Type:
B - Tripping Curve B
C - Tripping Curve C
D - Tripping Curve D
Aux Contacts:
Blank No Aux
1 - Position NO
2 - Position NC
3 - Fault NO
4 - Fault NC
5 - Position NO +
Fault NC
Additional
Branch Breakers:
Repeat Step 3
 Please use step by step catalog number on next page.
 Isolators are molded case Switches (MCS).
 For detailed information see table “Vigi iC60 Add-On Residual Current Devices (RCD or GFI)” on following pages.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1071
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Series and
Breaker Type:
P - PlexPower
Panel
with IEC
Breakers and
ATEX/IECEx
Certifications
M
Distribution Equipment
P
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Steps to Creating Catalog Number:
To create a complete catalog number, refer to the Catalog Numbering Guide on previous page. Product selection information in available
within the Guide.
P
P
E
Step 1
M
06
12
2
Step 2
16
C
G030
1
Step 3

Step 4
Step 5
Step 1: Series is P
Material is P
Choose panel arrangement (A, B, C, D, E or F; see drawing at the end of the section for number of circuits).
Step 2: Choose either main lug (L), isolator switch (S) or main circuit breaker (M)
Choose the ampere rating of incoming mains (3 or 4 poles plus ampere: 40, 50, 63, 80, 100, 125, 160, 200, 250)
If a main breaker is desired indicate amperage rating; Example: PPEM06 – 4-pole 63 Amp main breaker.
Step 3: Choose the number of branch breakers
Choose the number of poles
Choose the ampere rating
Choose the breaker type
Choose OPTIONAL GFI
Choose OPTIONAL auxiliary contacts
First digit is the number of branch breakers, second digit is the number of poles, third number is the ampere rating, forth number
is the breaker type and the fifth and six are optional GFI and/or auxiliary contacts; Example: 12216CG0301 is a 2-pole 16 Amp
breaker 30 mA GFI with one auxiliary position contact with tripping curve C
Step 4: Repeat Step 3 for as many breaker types are required (please refer to standard configurations)
Step 5: Panel options: Add options in alphanumeric order as listed Options in the Catalog Numbering Guide or Options in the introductory
section.
To be Noted When Selecting Panelboards
Entries for Mains Lugs, Isolator Switch, Main Circuit Breaker and Branch circuit breakers are based on rated Amps.
Entries
Incoming
Rating
Terminal
Size mm2
AWG
Wire Range
mm2
AWG
Entry
Sizes
Outgoing
Branches 
Terminal
Size mm2
AWG
Wire Range
mm2
AWG
Entry
Sizes
40 Amp
10
8
1.5 - 16
16-6
M25
20 Amp
6
8
1.5 - 10
22-8
M20
50 Amp
16
6
1.5 - 25
14-6
M32
32 Amp
6
8
1.5 - 10
22-8
M25
63 Amp
35
2
2.5 - 50
12-2
M32
40 Amp
10
8
1.5 - 16
16-8
M25
80 Amp
35
2
2.5 - 50
12-2
M32
50 Amp
16
6
1.5 - 25
14-6
M32
100 Amp
50
1/0
10 - 70
10-1/0
M32/M40
63 Amp
16
6
2.5 - 50
14-6
M32
125 Amp
50
1/0
10 - 70
10-1/0
M40/M50
160 Amp
70
2/0
10 - 95
8-2/0
M50/M63
200 Amp
120
4/0
16 - 150
4-4/0
M63/M75
250 Amp
120
4/0
16 - 150
4-4/0
M63/M75
 All outgoing entries must match respective cable sizes based on outgoing ratings.
1072
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Panel Arrangement Size Selection Guide
Bus Amps
Branch Breakers
8 Pole Module
Panel Arrangements 
C
D
E
3
4
6
F
9
Maximum no of circuits
1 Pole
16
24
32
48
72
1 Poles + Aux (NO or NC)
8
12
16
24
36
2 Poles
8
12
16
24
36
3 Poles
4
6
8
12
18
4 Poles
4
6
8
12
18
2 Poles + Aux (NO or NC)
4
6
8
12
18
3 Poles + Aux (NO or NC)
4
6
8
12
18
4Poles + Aux (NO or NC)
2
3
4
6
9
2 Poles + Aux (NO + NC)
4
6
8
12
18
3 Poles + Aux (NO + NC)
2
3
4
6
9
220-240/
380-415,
440 V
 Panel Arrangement A has the same number of circuits as Panel Arrangements B without the Mains.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1073
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
63-250 V
Volts
A/B
2
Distribution Equipment
Circuit configurations
Main Lugs, Isolator Switch or Main Breaker
Maximum no of 8 Poles modules in each Arrangement
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement Size Selection Guide (continued)
Circuit configurations
Main Lugs, Isolator Switch or Main Breaker
Maximum no of 8 Poles modules in each Arrangement
Bus Amps
63-250 V
Volts
Branch Breakers
A/B
2
8 Pole Module
Panel Arrangements 
C
D
E
3
4
6
F
9
Maximum no of circuits
4 Poles + Aux (NO + NC)
2
3
4
6
9
2 Poles + GFI
4
6
8
12
18
3 Poles + GFI
2
3
4
6
9
4 Poles + GFI
2
3
4
6
9
2 Poles + GFI + Aux (NO or NC)
4
6
8
12
18
3 Poles + GFI + Aux (NO or NC)
2
3
4
6
9
4 Poles + GFI + Aux (NO or NC)
2
3
4
6
9
2 Poles + GFI + Aux (NO + NC)
2
3
4
6
9
3 Poles + GFI + Aux (NO + NC)
2
3
4
6
9
4 Poles + GFI + Aux (NO + NC) 
2
3
4
6
9
220-240/
380-415,
440 V 
 Panel Arrangement A has the same number of circuits as Panel Arrangements B without the Mains.
 Up to 25 Amps only.
 440 V without GFI.
1074
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Schneider Mains Circuit Breaker (MCCB) Specifications
Distribution Equipment
Common Characteristics
Rated Voltages
Insulation voltage (V)
Ui
Impulse withstand voltage (kV)
Uimp
Operational voltage (V)
Ue
800
8
Suitability for isolation
Compliances
AC 50/60 Hz
690
IEC/EN 60947-2
Yes
Utilisation category
A
IEC 60664-1
3
Breaking Capacity
Circuit Breakers
NSX100
Breaking Capacity Levels 
Rated current (A)
B
F
In
Number of poles
N
H
S
NSX160
L
R
HB1
HB2

B
F
N
H
NSX250
S
L
B
F
N
H
S
L
R
HB1
HB2

100
100
160
250
250
2 , 3, 4
2 , 3, 4
2 , 3, 4
2 , 3, 4
2 , 3, 4
Breaking capacity (kA rms)
lcu AC 50/60 Hz
220/240 V 40 85 90 100 120 150 200
-
-
40 85 90 100 120 150 40 85 90 100 120 150 200
-
-
380/415 V 25 36 50 70 100 150 200
-
-
25 36 50 70 100 150 25 36 50 70 100 150 200
-
-
-
-
20 35 50 65 90 130 20 35 50 65 90 130 200
-
-
440 V
20 35 50 65 90 130 200
500 V
15 25 36 50 65 70 80 85 100 15 30 36 50 65 70 15 30 36 50 65 70 80 85 100
525 V
-
22 35 35 40 50 65 80 100
-
22 35 35 40 50
-
22 35 35 40 50 65 80 100
660/690 V
-
8
-
8
-
8
10 10 15 20 45 75 100
10 10 15 20
10 10 15 20 45 75 100
Service breaking capacity (kA rms)
lcs AC 50/60 Hz
220/240 V 40 85 90 100 120 150 200
-
-
40 85 90 100 120 150 40 85 90 100 120 150 200
-
-
380/415 V 25 36 50 70 100 150 200
-
-
25 36 50 70 100 150 25 36 50 70 100 150 200
-
-
-
-
20 35 50 65 90 130 20 35 50 65 90 130 200
-
-
440 V
20 35 50 65 90 130 200
500 V
7.5 12.5 36 50 65 70 80 85 100 15 30 36 50 65 70 15 30 36 50 65 70 80 85 100
525 V
-
11 35 35 40 50 65 80 100
-
22 35 35 40 50
-
22 35 35 40 50 65 80 100
660/690 V
-
4
-
8
-
8
10 10 15 20 45 75 100
10 10 15 20
10 10 15 20 45 75 100
 Electrical characteristics as per IEC 60947-2.
 There is no 160 A frame, use 250 A frame with lower amperage trip units for R, HB1, HB2.
 2P circuit breaker in 3P case for B and F types, only with thermal-magnetic trip unit.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1075
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Pollution degree
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Schneider Branch Circuit Breaker Specifications
iC60N Circuit Breakers — Standard Offering — Curve B, C, D
Alternating current (AC) 50/60 Hz — Breaking capacity (Icu) Ph/Ph (2P, 3P, 4P)
Ph/N (1P, 1P+N)
Rating (In)
12 to 133 V
12 to 60 V
Voltage (Ue) 
220 to 240 V
380 to 415 V
100 to 133 V
220 to 240 V
440 V
—
Voltage (Ue) 
400 V
230 V
Service Breaking
Capacity (Ics)
0.5 to 4 A
50 kA
50 kA
50 kA
25 kA
6 kA
100% of Icu
6 to 63 A
36 kA
20 kA
10 kA
6 kA
6 kA
75% of Icu
440 V
—
Voltage (Ue) 
400 V
230 V
Service Breaking
Capacity (Ics)
iC60H Circuit Breakers — Optional Offering — Curve B, C, D
Alternating current (AC) 50/60 Hz — Breaking capacity (Icu)
Ph/Ph (2P, 3P, 4P)
Ph/N (1P, 1P+N)
Rating (In)
12 to 133 V
12 to 60 V
Voltage (Ue) 
220 to 240 V
380 to 415 V
100 to 133 V
220 to 240 V
0.5 to 4 A
70 kA
70 kA
70 kA
50 kA
10 kA
100% of Icu
6 to 63 A
42 kA
30 kA
15 kA
10 kA
10 kA
50% of Icu
440 V
—
Voltage (Ue) 
400 V
230 V
Service Breaking
Capacity (Ics)
iC60L Circuit Breakers — Optional Offering — Curve B, C, K, Z
Alternating current (AC) 50/60 Hz — Breaking capacity (Icu) according to IEC/EN 60947-2
Ph/Ph (2P, 3P, 4P)
Ph/N (1P)
Rating (In)
12 to 133 V
12 to 60 V
Voltage (Ue) 
220 to 240 V
380 to 415 V
100 to 133 V
220 to 240 V
0.5 to 4 A
100 kA
100 kA
100 kA
70 kA
15 kA
100% of Icu
6 to 25 A
70 kA
50 kA
25 kA
20 kA
15 kA
50% of Icu
32/40 A
70 kA
36 kA
20 kA
15 kA
15 kA
50% of Icu
50/63 A
70 kA
30 kA
15 kA
10 kA
—
50% of Icu
 Breaking capacity (Icu) according to IEC/EN 60947-2.
 Breaking capacity (Icn) according to IEC/EN 60898-1.
1076
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Schneider Branch Circuit Breaker Specifications (continued)
Distribution Equipment
Vigi iC60 Add-On Residual Current Devices (RCD or GFI) — Optional
Voltage rating (Ue): 230 - 240 V, 400 - 415 V
Operating frequency: 50/60 Hz
Sensitivity
Amps
3P
4P
30 mA
300 mA
100 mA
0.5 to 25 A
X
X
X
X
32 to 40 A
—
X
X
—
50 to 63 A
—
X
X
X
0.5 to 25 A
—
X
X
—
32 to 40 A
—
X
X
—
50 to 63 A
—
X
X
—
0.5 to 25 A
—
X
X
X
32 to 40 A
—
X
X
—
50 to 63 A
—
X
X
X
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
2P
10 mA
Auxiliary Contact
Maximum
6 Amp
Terminal Size
Wire Range
mm2
AWG
mm2
AWG
2.5
12
1.5 - 4
26 - 12
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1077
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Cascading — Panelboard Short Circuit Ratings
Upstream: NSX100 — Downstream: iC60 — Ue: 380-415 V (Ph/N 220-240 V)
iC60N
iC60H
iC60L
Upstream
NSX100
NSX100B
NSX100F
NSX100N
NSX100H
NSX100S
NSX100L
Breaking capacity (kA)
25
36
50
70
100
150
Downstream
In Max (A)
Icu (kA)
63
10
20
25
30
30
30
30
40
15
25
36
40
40
40
40
63
15
25
36
36
36
36
36
25
25
—
36
40
40
40
40
40
20
25
36
40
40
40
40
63
15
25
36
36
36
36
36
Reinforced breaking capacity (kA)
Upstream: NSX160 — Downstream: C60 — Ue: 380-415 V (Ph/N 220-240 V)
iC60N
iC60H
iC60L
Upstream
NSX160
NSX160B
NSX160F
NSX160N
NSX160H
NSX160S
NSX160L
Breaking capacity (kA)
25
36
50
70
100
150
Downstream
In Max (A)
Icu (kA)
63
10
20
25
30
30
30
30
40
15
25
36
40
40
40
40
63
15
25
30
30
30
30
30
25
25
—
36
40
40
40
40
40
20
25
36
40
40
40
40
63
15
25
30
36
36
36
36
Reinforced breaking capacity (kA)
Upstream: NSX250 — Downstream: iC60 — Ue: 380-415 V (Ph/N 220-240 V)
iC60N
iC60H
iC60L
1078
Upstream
NSX250
NSX250B
NSX250F
NSX250N
NSX250H
NSX250S
NSX250L
Breaking capacity (kA)
25
36
50
70
100
150
Downstream
In Max (A)
Icu (kA)
40
10
20
25
30
30
30
30
63
10
20
25
25
25
25
25
40
15
25
30
30
30
30
30
63
15
25
25
25
25
25
25
25
25
—
30
30
30
30
30
40
20
25
30
30
30
30
30
63
15
25
25
25
25
25
25
Reinforced breaking capacity (kA)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Cascading — Panelboard Short Circuit Ratings (continued)
NSX100
NSX100B
NSX100F
NSX100N
NSX100H
NSX100S
NSX100L
20
35
50
65
90
130
6
15
15
20
20
20
20
Upstream
Breaking capacity (kA)
Downstream
Breaking Capacity (kA)
iC60H
iC60L
Reinforced breaking capacity (kA)
10
20
20
25
25
25
25
≤ 25 A
20
—
—
25
25
25
25
32-40 A
15
20
20
25
25
25
25
50-63 A
10
—
—
—
—
—
—
Upstream: NSX160 — Downstream: iC60 — Ue: 440 V
Upstream
NSX160
NSX160B
NSX160F
NSX160N
NSX160H
NSX160S
NSX160L
Breaking capacity (kA)
20
35
50
65
90
130
6
15
15
20
20
20
20
Downstream
Breaking Capacity (kA)
iC60N
iC60H
iC60L
Reinforced breaking capacity (kA)
10
20
20
25
25
25
25
≤ 25 A
20
—
—
25
25
25
25
32-40 A
15
20
20
25
25
25
25
50-63 A
10
—
—
—
—
—
—
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1079
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
iC60N
Distribution Equipment
Upstream: NSX100 — Downstream: iC60 — Ue: 440 V
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement A
Left Internal View
Front Internal View
Right Internal View
Branch Breakers
Armored Entries
1 Position 1 Trip
Incoming
Circuit
Outgoing
Size,
30mA Contact Contact Breaker
Main
“NO”
“NC”
Qty 1
Qty
Size
Breaker Curve C
GFI
Qty
Lugs Only
2-Poles 16 Amp —
—
—
8
4 x 63 Amp
M32
8
M20
2-Poles 16 Amp —
X
—
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp —
—
X
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp —
X
X
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
—
—
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
X
—
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
—
X
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
X
X
2
4 x 63 Amp
M32
2
M20
3-Poles 16 Amp —
—
—
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
X
—
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
—
X
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
X
X
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
—
—
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
X
—
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
—
X
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
X
X
2
3 x 63 Amp
M32
2
M20
4-Poles 16 Amp —
—
—
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp —
X
—
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp —
—
X
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp —
X
X
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
—
—
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
X
—
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
—
X
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
X
X
2
4 x 63 Amp
M32
2
M20
1080
A
Dimension in Millimeters (Inches)
26 (1.02)
B
102 (4.02)
C
33 (1.30)
D
109 (4.29)
Top Internal View
Non-Armored Entries
Incoming
Size
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
Armored
Outgoing
Auxilary,
Qty Size, Qty 1
Qty 1
8
M20
—
4
M20
M20
4
M20
M20
4
M20
M25
4
M20
—
4
M20
M20
4
M20
M20
2
M20
M25
4
M20
—
4
M20
M20
4
M20
M20
2
M20
M25
2
M20
—
2
M20
M20
2
M20
M20
2
M20
M20
4
M20
—
2
M20
M20
2
M20
M20
2
M20
M20
2
M20
—
2
M20
M20
2
M20
M20
2
M20
M20
NonArmored
Auxilary,
Qty 1
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Panel Arrangement A
Technical Information
750 x 320 x 150 mm
Panel Weight
40 kg (88 lb)
Max. No. of Circuits
See Panel Arrangement Size Selection Table
Voltage
220-240/380-415, 440
Wiring
See Wiring Diagram Table
Distribution Equipment
Panel A Size
Breaking Capacity in kA
380/415 V
-
440 V 
-
Bus-bar
100 A
-
-
Branch Breakers 
0.5 to 4 A
50
25
Branch Breakers 
6 to 63 A
10
6
Panel Arrangement
100 A, 3 Ph, 5 W
-
-
Terminals 
Qty 
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Incoming
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
Qty 
16
8
8
8
8
8
8
4
12
12
12
6
6
6
6
6
16
8
8
8
8
8
8
8
Outgoing
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
“NO”
Position
“NC”
Fault
Qty 
—
8
—
8
—
8
—
8
—
8
—
8
—
4
—
4
—
4
—
4
—
4
—
4
Qty 
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
Non-Armored 
Auxiliary
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
Complete Catalog No
PPAL068216C
PPAL064216C1
PPAL064216C4
PPAL064216C5
PPAL064216CG030
PPAL064216C1G030
PPAL064216C4G030
PPAL062216C5G030
PPAL054316C
PPAL054316C1
PPAL054316C4
PPAL052316C5
PPAL052316CG030
PPAL052316C1G030
PPAL052316C4G030
PPAL052316C5G030
PPAL064416C
PPAL062416C1
PPAL062416C4
PPAL062416C5
PPAL062416CG030
PPAL062416C1G030
PPAL062416C4G030
PPAL062416C5G030
Ordering Catalog No
PPAL068216C10N
PPAL064216C20N
PPAL064216C30N
PPAL064216C40N
PPAL064216C50N
PPAL064216C60N
PPAL064216C70N
PPAL062216C80N
PPAL054316C10N
PPAL054316C20N
PPAL054316C30N
PPAL052316C40N
PPAL052316C50N
PPAL052316C60N
PPAL052316C70N
PPAL052316C80N
PPAL064416C10N
PPAL062416C20N
PPAL062416C30N
PPAL062416C40N
PPAL062416C50N
PPAL062416C60N
PPAL062416C70N
PPAL062416C80N
 Ground bar supplied for each connection.
 Incoming cables terminates directly to the main breaker.
 Outgoing terminal blocks for branch breakers (provided).
 Each “NO” position contact are individually terminate on the terminal blocks and in pairs.
 All “NC” trip contacts must be wired in series and terminated on terminal blocks as one pair only.
 For armored version, replace the letter A with the letter N, in the last position of the Ordering Catalog Number; example: PPBL048216C10A.
 For higher kA rating please consult your local sales representative.
 Without GFI.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1081
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Mains
Ratings in Amps
63 A
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement B
A
Left Internal View
Front Internal View
Right Internal View
Branch Breakers
Armored Entries
1 Position 1 Trip
Incoming
Circuit
Main
Outgoing
Size,
30mA Contact Contact Breaker
Breaker
“NO”
“NC”
Qty 1
Qty
Size
Breaker Curve C
GFI
Qty
Size
2-Poles 16 Amp —
—
—
8
4 x 63 Amp
M32
8
M20
2-Poles 16 Amp —
X
—
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp —
—
X
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp —
X
X
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
—
—
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
X
—
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
—
X
4
4 x 63 Amp
M32
4
M20
2-Poles 16 Amp
X
X
X
2
4 x 63 Amp
M32
2
M20
3-Poles 16 Amp —
—
—
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
X
—
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
—
X
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
X
X
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
—
—
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
X
—
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
—
X
2
3 x 63 Amp
M32
2
M20
3-Poles 16 Amp
X
X
X
2
3 x 63 Amp
M32
2
M20
4-Poles 16 Amp —
—
—
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp —
X
—
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp —
—
X
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp —
X
X
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
—
—
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
X
—
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
—
X
2
4 x 63 Amp
M32
2
M20
4-Poles 16 Amp
X
X
X
2
4 x 63 Amp
M32
2
M20
Dimension in Millimeters (Inches)
171 (6.77)
B
53 (2.09)
C
57 (2.24)
D
126 (4.96)
Top Internal View
Non-Armored Entries
Incoming
Size
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
Armored
Outgoing
Auxilary,
Qty Size, Qty 1
Qty 1
8
M20
—
4
M20
M20
4
M20
M20
4
M20
M25
4
M20
—
4
M20
M20
4
M20
M20
2
M20
M25
4
M20
—
4
M20
M20
4
M20
M20
2
M20
M25
2
M20
—
2
M20
M20
2
M20
M20
2
M20
M20
4
M20
—
2
M20
M20
2
M20
M20
2
M20
M20
2
M20
—
2
M20
M20
2
M20
M20
2
M20
M20
NonArmored
Auxilary,
Qty 1
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
† Please note the followings:
• For KAIC ratings for mains, busbar and branch circuit breakers, refer to Coordination Study Chart.
• FRP coupled enclosures are mounted on side and top of each other.
• Alternative arrangement are available as option, consult local sales representative.
• Number of circuits shown are non GFI and without auxiliary contacts equipped breakers.
• GFI and auxiliary contact equipped breakers number of circuits are determined as total number of circuits. Standard arrangements for all possibilities are
listed in standard catalog pages
1082
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
Panel Arrangement B
Technical Information
990 x 666 x 230 mm
Panel Weight
70 kg (154 lb)
Max. No. of Circuits
See Panel Arrangement Size Selection Table
Voltage
220-240/380-415, 440
Wiring
See Wiring Diagram Table
Distribution Equipment
Panel B Size
Breaking Capacity in kA
380/415 V
25
440 V 
20
Bus-bar
125 A
50
50
Branch Breakers 
0.5 to 4 A
50
25
Branch Breakers 
6 to 63 A
10
6
Panel Arrangement
100 A, 3 Ph, 5 W
20
15
Terminals 
Qty 
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Incoming
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
Qty 
16
8
8
8
8
8
8
4
12
12
12
6
6
6
6
6
16
8
8
8
8
8
8
8
Outgoing
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
“NO”
Position
“NC”
Fault
Qty 
—
8
—
8
—
8
—
8
—
8
—
8
—
4
—
4
—
4
—
4
—
4
—
4
Qty 
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
Non-Armored 
Auxiliary
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
Complete Catalog No
PPBM068216C
PPBM064216C1
PPBM064216C4
PPBM064216C5
PPBM064216CG030
PPBM064216C1G030
PPBM064216C4G030
PPBM062216C5G030
PPBM054316C
PPBM054316C1
PPBM054316C4
PPBM052316C5
PPBM052316CG030
PPBM052316C1G030
PPBM052316C4G030
PPBM052316C5G030
PPBM064416C
PPBM062416C1
PPBM062416C4
PPBM062416C5
PPBM062416CG030
PPBM062416C1G030
PPBM062416C4G030
PPBM062416C5G030
Ordering Catalog No
PPBM068216C10N
PPBM064216C20N
PPBM064216C30N
PPBM064216C40N
PPBM064216C50N
PPBM064216C60N
PPBM064216C70N
PPBM062216C80N
PPBM054316C10N
PPBM054316C20N
PPBM054316C30N
PPBM052316C40N
PPBM052316C50N
PPBM052316C60N
PPBM052316C70N
PPBM052316C80N
PPBM064416C10N
PPBM062416C20N
PPBM062416C30N
PPBM062416C40N
PPBM062416C50N
PPBM062416C60N
PPBM062416C70N
PPBM062416C80N
 Ground bar supplied for each connection.
 Incoming cables terminates directly to the main breaker.
 Outgoing terminal blocks for branch breakers (provided).
 Each “NO” position contact are individually terminate on the terminal blocks and in pairs.
 All “NC” trip contacts must be wired in series and terminated on terminal blocks as one pair only.
 For armored version, replace the letter A with the letter N, in the last position of the Ordering Catalog Number; example: PPBM048216C10A.
 For higher kA rating please consult your local sales representative.
 Without GFI.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1083
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Mains
Ratings in Amps
100 A
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement C
A
Left Internal View
Front Internal View
Right Internal View
Armored Entries
Branch Breakers
Circuit
Main
1 Position 1 Trip
Incoming
Outgoing
Breaker
30mA Contact Contact Breaker
Size,
Qty
Size
Breaker Curve C
GFI
“NO”
“NC”
Qty 1
Qty
Size
2-Poles 16 Amp —
—
—
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp —
X
—
6
4 x 63 Amp
M32
6
M20
2-Poles 16 Amp —
—
X
6
4 x 63 Amp
M32
6
M20
2-Poles 16 Amp —
X
X
6
4 x 63 Amp
M32
6
M20
2-Poles 16 Amp
X
—
—
6
4 x 63 Amp
M32
6
M20
2-Poles 16 Amp
X
X
—
6
4 x 63 Amp
M32
6
M20
2-Poles 16 Amp
X
—
X
6
4 x 63 Amp
M32
6
M20
2-Poles 16 Amp
X
X
X
3
4 x 63 Amp
M32
3
M20
3-Poles 16 Amp —
—
—
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp —
X
—
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp —
—
X
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp —
X
X
3
3 x 63 Amp
M32
3
M20
3-Poles 16 Amp
X
—
—
3
3 x 63 Amp
M32
3
M20
3-Poles 16 Amp
X
X
—
3
3 x 63 Amp
M32
3
M20
3-Poles 16 Amp
X
—
X
3
3 x 63 Amp
M32
3
M20
3-Poles 16 Amp
X
X
X
3
3 x 63 Amp
M32
3
M20
4-Poles 16 Amp —
—
—
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp —
X
—
3
4 x 63 Amp
M32
3
M20
4-Poles 16 Amp —
—
X
3
4 x 63 Amp
M32
3
M20
4-Poles 16 Amp —
X
X
3
4 x 63 Amp
M32
3
M20
4-Poles 16 Amp
X
—
—
3
4 x 63 Amp
M32
3
M20
4-Poles 16 Amp
X
X
—
3
4 x 63 Amp
M32
3
M20
4-Poles 16 Amp
X
—
X
3
4 x 63 Amp
M32
3
M20
4-Poles 16 Amp
X
X
X
3
4 x 63 Amp
M32
3
M20
1084
Dimension in Millimeters (Inches)
170 (6.69)
B
61 (2.40)
C
70 (2.76)
D
147 (5.79)
Top Internal View
Non-Armored Entries
Incoming
Size
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
Armored
Outgoing
Auxilary,
Qty 1
Qty Size, Qty 1
12
M20
—
6
M20
M25
6
M20
M20
6
M20
M25
6
M20
—
6
M20
M20
6
M20
M20
3
M20
M20
6
M20
—
6
M20
M25
6
M20
M20
3
M20
M20
3
M20
—
3
M20
M20
3
M20
M20
3
M20
M20
6
M20
—
3
M20
M20
3
M20
M20
3
M20
M20
3
M20
—
3
M20
M20
3
M20
M20
3
M20
M20
NonArmored
Auxilary,
Qty 1
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Panel Arrangement C
Technical Information
1250 x 666 x 230 mm
Panel Weight
80 kg (176 lb)
Max. No. of Circuits
See Panel Arrangement Size Selection Table
Voltage
220-240/380-415, 440
Wiring
See Wiring Diagram Table
Distribution Equipment
Panel C Size
Breaking Capacity in kA
380/415 V
25
440 V 
20
Bus-bar
125 A
50
50
Branch Breakers 
0.5 to 4 A
50
25
Branch Breakers 
6 to 63 A
10
6
Panel Arrangement
125 A, 3 Ph, 5 W
20
15
Terminals 
Qty 
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Incoming
50 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
Qty 
24
12
12
12
12
12
12
6
18
18
18
9
9
9
9
9
24
12
12
12
12
12
12
12
Outgoing
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
“NO”
Position
“NC”
Fault
Qty 
—
12
—
12
—
12
—
12
—
12
—
6
—
6
—
6
—
6
—
6
—
6
—
6
Qty 
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
Non-Armored 
Auxiliary
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
Complete Catalog No
PPCM1212216C
PPCM066216C1
PPCM066216C4
PPCM066216C5
PPCM066216CG030
PPCM066216C1G030
PPCM066216C4G030
PPCM063216C5G030
PPCM056316C
PPCM056316C1
PPCM056316C4
PPCM053316C5
PPCM053316CG030
PPCM053316C1G030
PPCM053316C4G030
PPCM053316C5G030
PPCM066416C
PPCM063416C1
PPCM063416C4
PPCM063416C5
PPCM063416CG030
PPCM063416C1G030
PPCM063416C4G030
PPCM063416C5G030
Ordering Catalog No
PPCM1212216C10N
PPCM066216C20N
PPCM066216C30N
PPCM066216C40N
PPCM066216C50N
PPCM066216C60N
PPCM066216C70N
PPCM063216C80N
PPCM056316C10N
PPCM056316C20N
PPCM056316C30N
PPCM053316C40N
PPCM053316C50N
PPCM053316C60N
PPCM053316C70N
PPCM053316C80N
PPCM066416C10N
PPCM063416C20N
PPCM063416C30N
PPCM063416C40N
PPCM063416C50N
PPCM063416C60N
PPCM063416C70N
PPCM063416C80N
 Ground bar supplied for each connection.
 Incoming cables terminates directly to the main breaker.
 Outgoing terminal blocks for branch breakers (provided).
 Each “NO” position contact are individually terminate on the terminal blocks and in pairs.
 All “NC” trip contacts must be wired in series and terminated on terminal blocks as one pair only.
 For armored version, replace the letter A with the letter N, in the last position of the Ordering Catalog Number; example: PPCM0812216C10A.
 For higher kA rating please consult your local sales representative.
 Without GFI.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1085
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Mains
Ratings in Amps
125 A
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement D
A
Left Internal View
Front Internal View
Right Internal View
Branch Breakers
Armored Entries
Circuit
Main
1 Position 1 Trip
Incoming
Outgoing
30mA Contact Contact Breaker
Breaker
Size,
Breaker Curve C
GFI
Qty
Size
“NO”
“NC”
Qty 1
Qty
Size
2-Poles 16 Amp —
—
—
16
4 x 160 Amp
M50
16
M20
2-Poles 16 Amp —
X
—
8
4 x 100 Amp
M40
8
M20
2-Poles 16 Amp —
—
X
8
4 x 100 Amp
M40
8
M20
2-Poles 16 Amp —
X
X
8
4 x 100 Amp
M40
8
M20
2-Poles 16 Amp
X
—
—
8
4 x 100 Amp
M40
8
M20
2-Poles 16 Amp
X
X
—
8
4 x 100 Amp
M40
8
M20
2-Poles 16 Amp
X
—
X
8
4 x 100 Amp
M40
8
M20
2-Poles 16 Amp
X
X
X
4
4 x 63 Amp
M32
4
M20
3-Poles 16 Amp —
—
—
8
3 x 100 Amp
M40
8
M20
3-Poles 16 Amp —
X
—
8
3 x 100 Amp
M40
8
M20
3-Poles 16 Amp —
—
X
8
3 x 100 Amp
M40
8
M20
3-Poles 16 Amp —
X
X
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp
X
—
—
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp
X
X
—
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp
X
—
X
4
3 x 63 Amp
M32
4
M20
3-Poles 16 Amp
X
X
X
4
3 x 63 Amp
M32
4
M20
4-Poles 16 Amp —
—
—
8
4 x 63 Amp
M32
8
M20
4-Poles 16 Amp —
X
—
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp —
—
X
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp —
X
X
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp
X
—
—
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp
X
X
—
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp
X
—
X
4
4 x 63 Amp
M32
4
M20
4-Poles 16 Amp
X
X
X
4
4 x 63 Amp
M32
4
M20
1086
Dimension in Millimeters (Inches)
171 (6.73)
B
53 (2.09)
C
58 (2.28)
D
127 (5.00)
Top Internal View
Non-Armored Entries
Incoming
Size
M50
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
Armored
Auxilary,
Qty 1
Qty Size, Qty 1
16
M20
—
8
M20
M25
8
M20
M20
8
M20
M25
8
M20
—
8
M20
M25
8
M20
M20
4
M20
M25
8
M20
—
8
M20
M25
8
M20
M20
4
M20
M25
4
M20
—
4
M20
M20
4
M20
M20
4
M20
M25
8
M20
—
4
M20
M20
4
M20
M20
4
M20
M25
4
M20
—
4
M20
M20
4
M20
M20
4
M20
M25
Outgoing
NonArmored
Auxilary,
Qty 1
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Panel Arrangement D
Technical Information
990 x 994 x 230 mm
Panel Weight
120 kg (265 lb)
Max. No. of Circuits
See Panel Arrangement Size Selection Table
Voltage
220-240/380-415, 440
Wiring
See Wiring Diagram Table
Distribution Equipment
Panel D Size
Breaking Capacity in kA
380/415 V
440 V 
Mains
160 A
25
20
Bus-bar
160 A
50
50
25
Branch Breakers 
0.5 to 4 A
50
Branch Breakers 
6 to 63 A
10
6
Panel Arrangement
160 A, 3 Ph, 5 W
20
15
Terminals 
Qty 
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Incoming
70 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
35 mm2
50 mm2
50 mm2
50 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
Qty 
32
16
16
16
16
16
16
8
24
24
24
12
12
12
12
12
32
16
16
16
16
16
16
16
Outgoing
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
“NO”
Position
“NC”
Fault
Qty 
—
16
—
16
—
16
—
8
—
16
—
8
—
8
—
8
—
8
—
8
—
8
—
8
Qty 
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
Non-Armored 
Auxiliary
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
Complete Catalog No
PPDM1416216C
PPDM108216C1
PPDM108216C4
PPDM108216C5
PPDM108216CG030
PPDM108216C1G030
PPDM108216C4G030
PPDM064216C5G030
PPDM098316C
PPDM098316C1
PPDM098316C4
PPDM054316C5
PPDM054316CG030
PPDM054316C1G030
PPDM054316C4G030
PPDM054316C5G030
PPDM068416C
PPDM064416C1
PPDM064416C4
PPDM064416C5
PPDM064416CG030
PPDM064416C1G030
PPDM064416C4G030
PPDM064416C5G030
Ordering Catalog No
PPDM1416216C10N
PPDM108216C20N
PPDM108216C30N
PPDM108216C40N
PPDM108216C50N
PPDM108216C60N
PPDM108216C70N
PPDM064216C80N
PPDM098316C10N
PPDM098316C20N
PPDM098316C30N
PPDM054316C40N
PPDM054316C50N
PPDM054316C60N
PPDM054316C70N
PPDM054316C80N
PPDM068416C10N
PPDM064416C20N
PPDM064416C30N
PPDM064416C40N
PPDM064416C50N
PPDM064416C60N
PPDM064416C70N
PPDM064416C80N
 Ground bar supplied for each connection.
 Incoming cables terminates directly to the main breaker.
 Outgoing terminal blocks for branch breakers (provided).
 Each “NO” position contact are individually terminate on the terminal blocks and in pairs.
 All “NC” trip contacts must be wired in series and terminated on terminal blocks as one pair only.
 For armored version, replace the letter A with the letter N, in the last position of the Ordering Catalog Number; example: PPDM1016216C10A.
 For higher kA rating please consult your local sales representative.
 Without GFI.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1087
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Ratings in Amps
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement E
A
Left Internal View
Front Internal View
Right Internal View
Branch Breakers
Armored Entries
1 Position 1 Trip
Incoming
Circuit
Main
Outgoing
Size,
30mA Contact Contact Breaker
Breaker
Qty
Size
“NO”
“NC”
Qty 1
Breaker Curve C
GFI
Qty
Size
2-Poles 16 Amp —
—
—
24
4 x 200 Amp
M63
24
M20
2-Poles 16 Amp —
X
—
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp —
—
X
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp —
X
X
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp
X
—
—
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp
X
X
—
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp
X
—
X
12
4 x 125 Amp
M40
12
M20
2-Poles 16 Amp
X
X
X
6
4 x 63 Amp
M32
6
M20
3-Poles 16 Amp —
—
—
12
3 x 125 Amp
M40
12
M20
3-Poles 16 Amp —
X
—
12
3 x 125 Amp
M40
12
M20
3-Poles 16 Amp —
—
X
12
3 x 125 Amp
M40
12
M20
3-Poles 16 Amp —
X
X
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp
X
—
—
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp
X
X
—
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp
X
—
X
6
3 x 63 Amp
M32
6
M20
3-Poles 16 Amp
X
X
X
6
3 x 63 Amp
M32
6
M20
4-Poles 16 Amp —
—
—
12
4 x 63 Amp
M32
12
M20
4-Poles 16 Amp —
X
—
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp —
—
X
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp —
X
X
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp
X
—
—
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp
X
X
—
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp
X
—
X
6
4 x 63 Amp
M32
6
M20
4-Poles 16 Amp
X
X
X
6
4 x 63 Amp
M32
6
M20
1088
Dimension in Millimeters (Inches)
171 (6.73)
B
61 (2.40)
C
70 (2.76)
D
147 (5.79)
Top Internal View
Non-Armored Entries
Incoming
Size
M63
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
M40
Armored
Outgoing
Auxilary,
Qty Size, Qty 1
Qty 1
24
M20
—
12
M20
M32
12
M20
M20
12
M20
M32
12
M20
—
12
M20
M32
12
M20
M20
6
M20
M25
12
M20
—
12
M20
M32
12
M20
M20
6
M20
M25
6
M20
—
6
M20
M25
6
M20
M20
6
M20
M25
12
M20
—
6
M20
M25
6
M20
M20
6
M20
M25
6
M20
—
6
M20
M25
6
M20
M20
M20
M25
NonArmored
Auxilary,
Qty 1
—
M32
M25
M32
—
M32
M25
M25
—
M32
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Panel Arrangement E
Technical Information
1250 x 994 x 230 mm
Panel Weight
145 kg (320 lb)
Max. No. of Circuits
See Panel Arrangement Size Selection Table
Voltage
220-240/380-415
Wiring
See Wiring Diagram Table
Distribution Equipment
Panel E Size
Breaking Capacity in kA
380/415 V
25
440 V 
20
Bus-bar
250 A
50
50
Branch Breakers 
0.5 to 4 A
50
25
Branch Breakers 
6 to 63 A
10
6
Panel Arrangement
200 A, 3 Ph, 5 W
20
-
Terminals 
Qty 
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Incoming
120 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
35 mm2
50 mm2
50 mm2
50 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
35 mm2
Qty 
48
24
24
24
24
24
24
12
24
24
24
18
18
18
18
18
48
24
24
24
24
24
24
24
Outgoing
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
“NO”
Position
“NC”
Fault
Qty 
—
24
—
24
—
24
—
12
—
24
—
12
—
12
—
12
—
12
—
12
—
12
—
12
Qty 
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
Non-Armored 
Auxiliary
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
Complete Catalog No
PPEM1624216C
PPEM1212216C1
PPEM1212216C4
PPEM1212216C5
PPEM1212216CG030
PPEM1212216C1G030
PPEM1212216C4G030
PPEM066216C5G030
PPEM1112316C
PPEM1112316C1
PPEM1112316C4
PPEM056316C5
PPEM056316CG030
PPEM056316C1G030
PPEM056316C4G030
PPEM056316C5G030
PPEM0612416C
PPEM066416C1
PPEM066416C4
PPEM066416C5
PPEM066416CG030
PPEM066416C1G030
PPEM066416C4G030
PPEM066416C5G030
Ordering Catalog No
PPEM1624216C10N
PPEM1212216C20N
PPEM1212216C30N
PPEM1212216C40N
PPEM1212216C50N
PPEM1212216C60N
PPEM1212216C70N
PPEM066216C80N
PPEM1112316C10N
PPEM1112316C20N
PPEM1112316C30N
PPEM056316C40N
PPEM056316C50N
PPEM056316C60N
PPEM056316C70N
PPEM056316C80N
PPEM0612416C10N
PPEM066416C20N
PPEM066416C30N
PPEM066416C40N
PPEM066416C50N
PPEM066416C60N
PPEM066416C70N
PPEM066416C80N
 Ground bar supplied for each connection.
 Incoming cables terminates directly to the main breaker.
 Outgoing terminal blocks for branch breakers (provided).
 Each “NO” position contact are individually terminate on the terminal blocks and in pairs.
 All “NC” trip contacts must be wired in series and terminated on terminal blocks as one pair only.
 For armored version, replace the letter A with the letter N, in the last position of the Ordering Catalog Number; example: PPEM1224216C10A.
 For higher kA rating please consult your local sales representative.
 Without GFI.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1089
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Mains
Ratings in Amps
200 A
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Panel Arrangement F
A
Left Internal View
Front Internal View
Right Internal View
Armored Entries
Branch Breakers
Circuit
Main
1 Position 1 Trip
Incoming
Outgoing
Breaker
30mA Contact Contact Breaker
Size,
Qty
Size
Breaker Curve C
GFI
“NO”
“NC”
Qty 1
Qty
Size
2-Poles 16 Amp —
—
—
36
4 x 250 Amp
M63
36
M20
2-Poles 16 Amp —
X
—
18
4 x 200 Amp
M63
18
M20
2-Poles 16 Amp —
—
X
18
4 x 200 Amp
M63
18
M20
2-Poles 16 Amp —
X
X
18
4 x 200 Amp
M63
18
M20
2-Poles 16 Amp
X
—
—
18
4 x 200 Amp
M63
18
M20
2-Poles 16 Amp
X
X
—
18
4 x 200 Amp
M63
18
M20
2-Poles 16 Amp
X
—
X
18
4 x 200 Amp
M63
18
M20
2-Poles 16 Amp
X
X
X
9
4 x 100 Amp
M40
9
M20
3-Poles 16 Amp —
—
—
18
3 x 200 Amp
M63
18
M20
3-Poles 16 Amp —
X
—
18
3 x 200 Amp
M63
18
M20
3-Poles 16 Amp —
—
X
18
3 x 200 Amp
M63
18
M20
3-Poles 16 Amp —
X
X
9
3 x 100 Amp
M40
9
M20
3-Poles 16 Amp
X
—
—
9
3 x 100 Amp
M40
9
M20
3-Poles 16 Amp
X
X
—
9
3 x 100 Amp
M40
9
M20
3-Poles 16 Amp
X
—
X
9
3 x 100 Amp
M40
9
M20
3-Poles 16 Amp
X
X
X
9
3 x 100 Amp
M40
9
M20
4-Poles 16 Amp —
—
—
18
4 x 200 Amp
M63
18
M20
4-Poles 16 Amp —
X
—
9
4 x 100 Amp
M40
9
M20
4-Poles 16 Amp —
—
X
9
4 x 100 Amp
M40
9
M20
4-Poles 16 Amp —
X
X
9
4 x 100 Amp
M40
9
M20
4-Poles 16 Amp
X
—
—
9
4 x 100 Amp
M40
9
M20
4-Poles 16 Amp
X
X
—
9
4 x 100 Amp
M40
9
M20
4-Poles 16 Amp
X
—
X
9
4 x 100 Amp
M40
9
M20
4-Poles 16 Amp
X
X
X
9
4 x 100 Amp
M40
9
M20
1090
Dimension in Millimeters (Inches)
150 (5.91)
B
61 (2.40)
C
70 (2.76)
D
147 (5.79)
Top Internal View
Non-Armored Entries
Incoming
Size
M63
M63
M63
M63
M63
M63
M63
M40
M63
M63
M63
M40
M40
M40
M40
M40
M63
M40
M40
M40
M40
M40
M40
M40
Armored
Outgoing
Auxilary,
Qty 1
Qty Size, Qty 1
36
M20
—
18
M20
M32
18
M20
M20
18
M20
M32
18
M20
—
18
M20
M32
18
M20
M20
9
M20
M32
18
M20
—
18
M20
M32
18
M20
M20
9
M20
M32
9
M20
—
9
M20
M25
9
M20
M20
9
M20
M32
18
M20
—
9
M20
M25
9
M20
M20
9
M20
M32
9
M20
—
9
M20
M25
9
M20
M20
9
M20
M32
NonArmored
Auxilary,
Qty 1
—
M40
M25
M40
—
M40
M25
M25
—
M40
M25
M25
—
M25
M25
M25
—
M25
M25
M25
—
M25
M25
M25
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx — Optional:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIC
Ex tb IIIC
IP66/Ik10
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II2GD
EPL Gb Db
Ex db eb IIB+H2
Ex tb IIIC
IP66/Ik10
Panel Arrangement F
Technical Information
1470 x 1323 x 230 mm
Panel Weight
200 kg (441 lb)
Max. No. of Circuits
See Panel Arrangement Size Selection Table
Voltage
220-240/380-415
Wiring
See Wiring Diagram Table
Distribution Equipment
Panel A Size
Breaking Capacity in kA
380/415 V
25
440 V 
20
Bus-bar
250 A
50
50
Branch Breakers 
0.5 to 4 A
50
25
Branch Breakers 
6 to 63 A
10
6
Panel Arrangement
250 A, 3 Ph, 5 W
20
-
Terminals 
Qty 
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
Incoming
120 mm2
120 mm2
120 mm2
120 mm2
120 mm2
120 mm2
120 mm2
50 mm2
120 mm2
120 mm2
120 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
120 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
50 mm2
Qty 
72
36
36
36
36
36
36
18
36
36
36
18
18
18
18
18
36
18
18
18
18
18
18
18
Outgoing
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
6 mm2
“NO”
Position
“NC”
Fault
Qty 
—
36
—
36
—
36
—
18
—
36
—
18
—
18
—
18
—
18
—
18
—
18
—
18
Qty 
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
—
—
2
2
Non-Armored 
Auxiliary
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
—
2.5 mm2
2.5 mm2
2.5 mm2
Complete Catalog No
PPFM1836216C
PPFM1618216C1
PPFM1618216C4
PPFM1618216C5
PPFM1618216CG030
PPFM1618216C1G030
PPFM1618216C4G030
PPFM109216C5G030
PPFM1518316C
PPFM1518316C1
PPFM1518316C4
PPFM099316C5
PPFM099316CG030
PPFM099316C1G030
PPFM099316C4G030
PPFM099316C5G030
PPFM1618416C
PPFM109416C1
PPFM109416C4
PPFM109416C5
PPFM109416CG030
PPFM109416C1G030
PPFM109416C4G030
PPFM109416C5G030
Ordering Catalog No
PPFM1836216C10N
PPFM1618216C20N
PPFM1618216C30N
PPFM1618216C40N
PPFM1618216C50N
PPFM1618216C60N
PPFM1618216C70N
PPFM109216C80N
PPFM1518316C10N
PPFM1518316C20N
PPFM1518316C30N
PPFM099316C40N
PPFM099316C50N
PPFM099316C60N
PPFM099316C70N
PPFM099316C80N
PPFM1618416C10N
PPFM109416C20N
PPFM109416C30N
PPFM109416C40N
PPFM109416C50N
PPFM109416C60N
PPFM109416C70N
PPFM109416C80N
 Ground bar supplied for each connection.
 Incoming cables terminates directly to the main breaker.
 Outgoing terminal blocks for branch breakers (provided).
 Each “NO” position contact are individually terminate on the terminal blocks and in pairs.
 All “NC” trip contacts must be wired in series and terminated on terminal blocks as one pair only.
 For armored version, replace the letter A with the letter N, in the last position of the Ordering Catalog Number; example: PPFM1436216C10A.
 For higher kA rating please consult your local sales representative.
 Without GFI.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1091
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Mains
Ratings in Amps
250 A
P Series PlexPower™ Distribution Panelboards
Increased Safety
Wiring Diagrams — Panel Arrangements B, C, D, E, F — For Panel Arrangement A, Remove Main Breaker from Wiring Diagrams
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Q1: Main Breaker
M1-M8: Module Housing
D1-: MCB
2-Pole
2-Pole + GFI
2-Pole + GFI + AUX NO + AUX NC
 Number of branch circuit breakers will depend on the number of module housing.
1092
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
Standard Panel Arrangement Layout — Dimensions in Millimeters (Inches)
Distribution Equipment
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Panel Arrangement A
Panel Arrangement B
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1093
P Series PlexPower™ Distribution Panelboards
Increased Safety
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Distribution Equipment
Standard Panel Arrangement Layout — Dimensions in Millimeters (Inches)
Panel Arrangement C
Panel Arrangement D
1094
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
P Series PlexPower™ Distribution Panelboards
Increased Safety
Standard Panel Arrangement Layout — Dimensions in Millimeters (Inches)
Distribution Equipment
ATEX/IECEx/NBR IEC INCREASED SAFETY Ex e/FLAMEPROOF Ex d ZONE 1 RATED PANELBOARDS
Panel Arrangement E
Panel Arrangement F
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2015
1095
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising