CircFans_Lit

CircFans_Lit
52” PANEL FANS
Innovative
•
Low Cost
•
Low Maintenance
Ideal for Dairy Cow Cooling
Warranty
Features
• New sturdier design
• Simple low cost design
• Strong, versatile wall/ceiling mount included.
• 1 hp motor available in 60 Hz, phase or 3 phase for North America
and 50 Hz for Europe
• Low maintenance
• 1 year warranty on fan
AVAILABILITY This product is seasonal.
Please call for delivery
information.
Performance Data & Specifications
Blade
Diameter
Motor Size
PF52-A1
52"
PF52-A3
52"
Model
Volts
Motor
RPM
Phase
Speed
CFM
Shipping
Weight (lbs)
1 HP
230
600
1
1
28,000
195 lbs
1 HP
230/460
600
3
1
28,000
195 lbs
Velocity Mapping Charts
These charts indicate the air
distribution pattern.
They are graphic illustrations of
air velocity in feet per minute.
PF52
20
15
10
5
600 ft/min
0
400 ft/min
200 ft/min
100 ft/min
5
10
15
20
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
CANARM LTD. - Corporate Office
2157 Parkedale Ave., PO Box 367 Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Web Site: www.canarm.com
Subject to Change without notice.
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
E-Mail: [email protected]
Printed in Canada - 12/12
PRF POLY ROUND FANS
Effective Cooling
•
Low Cost
•
Innovative
Ideal for Cow & Poultry Cooling
36” PRF Poly Round Fan
Features
• 36” diameter
• Strong, versatile wall/ceiling mount included
• Versatile - hangs quickly and points anywhere
• Strong, powder coated steel guards
• 1/2 hp, 230 volt single or 3 phase motor
• Durable poly wrapper
Performance Data & Specifications
MODEL
SIZE
H.P.
BLADE
PADDLE
VOLTS
AMPS
Phs
RPM
SPEED
CFM
0" SP
CARTON
DIMENSIONS
PRF36
36"
1/2
3
115/230
6.6/3.3
1
850
Single
11,500
43" x 43" x 12.5"
PRF363
36"
1/2
3
230/460
5.4/2.7
3
850
Single
11,500
43" x 43" x 12.5"
Velocity Mapping Chart
This chart indicates the air distribution pattern.
It is a graphic illustration of air velocity in feet per minute.
Warranty
PRF36 & PRF363
• 1 year warranty on fan
10
5
400 ft/min
0
300 ft/min
200 ft/min
100 ft/min
Availability:
5
This model is seasonal.
Please call for delivery details.
10
10
20
30
40
50
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Ted: (613) 342-5424 Fax: 1-800-263-4598
60
70
80
90
100 110 120 130
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Ted: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Ted: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 02/11
PLASTIC BOX STIR FANS
High Performance
•
Maintenance Free •
Corrosion Proof Housing
Ideally suited for air cooling Poultry, Dairy and Swine Livestock
Features
Mounting Options
• 36” and 48” models.
CPF36 with Hanging Bracket Kit
• Patented design provides higher air volumes at maximum efficiency
(U.S. Patent #5,803,709)
• The poly box design is virtually self-cleaning and will not rust, peel,
chip or rot.
• The gray poly box is UV treated and will stay looking like new through
years of use.
• Fans are provided with 2 x 2 galvanized wire mesh screens.
• Motors are high efficiency and direct drive. The three phase 1/2 hp
motors have built in thermal protection for the dairy market.
• The fans can be suspended from the corner clips provided on the fans
or easily angled using the hanging bracket kit accessories.
Availability:
This model is seasonal.
Please call for delivery details.
Specifications
PART #
SIZE
H.P.
BLADE
PADDLE
CPF36G38G20
36"
1/2
3
CPF36G44G20
36"
1/2
3
CPF48G23G20
48"
1
3
*CPF48G26G20
48"
1
3
AMPS
Phs
RPM
SPEED
CFM
0" SP
CFM/
WATT
DIMENSIONS
115/230
6/3
1
850
Single
12,200
21.3
40" x 40" x 13"
208-230/460
2.4/1.2
3
850
Single
12,200
23.0
40" x 40" x 13"
230
5
1
850
Single
21,000
22.4
52" x 52" x 11"
208-230/460
5.2/2.6
3
850
Single
21,000
24.0
52" x 52" x 11"
VOLTS
Notes: * Thermal protection not included
Accessories - Cord Kit - 240V 10’ cord & plug
Warranty
• 1 year warranty on fan
Subject to Change without notice.
Printed in Canada - 02/11
PLASTIC BOX STIR FANS
Velocity Mapping Charts
These charts indicate the air distribution pattern.
They are graphic illustrations of air velocity in feet per minute.
CPF36 - 3 Paddle
CPF48
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 02/11
ROUND PORTABLE FANS
Economical
• High Velocity • Easy to Move
Canarm’s “HVR” High Velocity Round Portable Fans Circulate Large Volumes of Air.
Ceiling Mount
Easily Adjustable/Strong Locking
HVR36
HVR Series
•
•
•
•
•
•
•
•
•
•
HVR24
Features
Heavy 18 gauge, powder coated steel housing.
Factory balanced blade.
Permanently lubricated, totally enclosed motors.
2 speed dial switch on 24” & 36” models.
Fan drum easily pivots up for directional control with strong locking mechanism.
Complete with 10’, 120V grounded cord.
Powder coated front and rear guards meet OSHA standards.
Heavy duty wheel kit makes this fan easy to move.
5” (HVR24) and 8” (HVR36) rubber wheels with steel hubs.
Complete with conversion kit for ceiling mount.
Convenient Dial Switch
Performance Data & Specifications
AVAILABILITY
Model Number
Size
Speed
H.P.
RPM
CFM
Volts
Amps
Weight (lbs.)
HVR24
24"
2
1/3
1100
7,000
120
1.8
43
HVR36
36"
2
1/2
825
12,000
120
4.9
103
Velocity Mapping Charts
These charts show the air distribution pattern. They are graphic illustrations of air velocity in feet per minute.
HVR24
HVR36
10
10
5
5
0
200 ft/min
100 ft/min 50 ft/min
0
5
5
10
10
10
This product is
seasonal.
Please call for
delivery
information.
20
30
40
50
Subject to Change without notice.
60
70
80
90
100
400 ft/min
300 ft/min
200 ft/min
100 ft/min
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Printed in Canada - 11/11
STAINLESS STEEL PANEL FAN
High Performance
•
Low Maintenance
•
Easy Installation
Canarm’s “TF” series stainless steel circulating panel fans are designed for use as air tube
circulators, exhaust and chimney or circulating fans for hog, poultry, dairy and greenhouses.
TF Series
Front
Back
Features
• Available in 12”, 16”, 24” and 36” sizes.
• Dual voltage, totally enclosed, variable speed (except for 36”), high efficiency ball bearing motors with thermal overload
protection.
• Canarm’s exclusive “Rotair” air foil polypropylene blade is designed to deliver high volumes of air quietly and efficiently.
• The single speed 36” model has a high performance galvanized blade.
• Stainless steel panel will not rust and has an 4” extension to allow the installation of an air bag.
• All fans are shipped completely assembled.
General Information
Canarm’s “TF” Series Stainless Steel Circulating Panel Fans are designed for use in many applications.
Four pre-punched mounting holes make the “TF” series fans easy to hang from chains or for permanent installation as a sidewall
exhaust fan or chimney fan.
The “TF” series stainless steel fan is ideally suited for use in recirculating ducts or air bags. An extension on the venturi is
designed to make Air Bag attachment quick and easy.
Subject to Change without notice.
Printed in Canada - 02/11
STAINLESS STEEL PANEL FAN
Dimensions
FAN
A
B
C
D
E
TF12
17.250
16.750
5.750
12.500
16.000
TF16
21.250
16.750
5.750
16.500
20.000
TF24
29.250
16.750
5.750
24.625
28.000
TF36
38.875
12.500
3.625
36.750
37.500
Performance Data & Specifications
MODEL
FAN
DIA.
MOTOR
H.P.
MOTOR
TYPE
TF12
12"
1/4
TF16
16"
1/4
TF24
24"
1/2
High
Efficiency
Variable
Speed Dual
Voltage
TF36
36"
1/2
Single
FAN
RPM
CURRENT LOAD
AIRFLOW CAPACITY - CFM
@115V
@230V
0" SP
.05" SP
.10" SP
CFM/
WATT
FRAMING
DIMENSIONS
SHIPPING
WGT. LBS.
1750
2.6
1.3
1,380
1,260
1,170
7.5
15 x 15
24
1750
3.4
1.7
2,810
2,680
2,540
8.0
19 x 19
27
1750
5.0
2.5
5,200
4,880
4,600
9.2
27 x 27
40
850
6.0
3.0
11,000
10,500
10,000
20.0
37 x 37
40
Warranty
• 1 year on all components
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 02/11
BASKET TYPE CIRCULATING FANS
High Performance
•
OSHA Guards
•
Corrosion Resistant
Ideally suited for all Agricultural applications.
CA-AG Circulating Fan (Ceiling Mount Shown)
CA-AG Series
Features
• Variable speed, totally enclosed, sealed ball bearing, thermally protected, high efficiency, dual voltage, 115/230V
• High volume, corrosion resistant blades
• Polyester powder coated, steel wire guard to OSHA specifications
• Galvanized Steel adjustable three way mount. Mount to wall, ceiling or overhead joist. Fan can pivot down and swivel
left and right for pin-point control of air stream.
• Fan head comes pre-assembled to guarantee fan blade is in proper location on motor shaft for maximum performance
and safety within the guard.
• Can operate with Canarm’s manual or automatic thermostatic controls (sold separately)
• The fans should move air from the inlets towards the exhaust fans and into all areas to remove dead air pockets. The
airstream should be directed across the back of the head and shoulders of the animals
• Suitable for buildings with low ceilings
*Detailed product specifications on back
Mounting Options
Wall Mount
Ceiling Mount
Pivots
Down
Ceiling Mount
Extended
Pivots
Down
Pivots
Down
Subject to Change without notice.
Ceiling Mount
Overhead Joist
Swivels
Left & Right
Printed in Canada - 02/11
BASKET TYPE CIRCULATING FANS
Performance Data & Specifications
Model Number
Size
H.P.
RPM/Speed
CFM
Voltage
Amps
Weight (lbs.)
CA20AG-FVD
20"
1/3
1625/Variable Speed
6,500
115/230V
4.2/2.1
37
CA24AG-GV11
24"
1/2
1100/Variable Speed
8,500
115/230V
6.4/3.2
44
CA30AG-GV11
30"
1/2
1100/Variable Speed
11,000
115/230V
6.4/3.2
50
Velocity Mapping Charts
These charts indicate the air distribution pattern. They are graphic illustrations of air velocity in feet per minute.
CA20AG-FVD
CA24AG-GV11
CA30AG-GV11
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 02/11
18” HORIZONTAL AIR FLOW FANS
High Performance
• Gentle Air Flow
• Energy Efficient
Suitable for wet locations.
General Information
Canarm's HAF18 Horizontal airflow fan is designed to provide gentle circulation of air in greenhouses and other
agricultural applications.
The HAF18 features a 1/15 HP totally enclosed, 115V, 0.9 amps motor.
The variable speed motor can be adjusted accordingly to meet your requirements.
It features open guard spacing for better air distribution and a hanging bracket.
When suspended, fan can pivot up and down and swivel 360˚ for optimal control of air stream.
Features
• 18” horizontal air flow fan
• Suitable for wet locations
• Totally enclosed motor
• 115V, 8 foot grounded cord & plug
• Powder coated guard has wide spacing
to eliminate the build up of debris.
Velocity Mapping Chart
Performance Data & Specifications - HAF18
This chart indicates the air distribution pattern.
It is a graphic illustration of air velocity in feet per minute.
HAF18
5
200 ft/min
0
100 ft/min
50 ft/min
Blade
Diameter
Motor
Size
(HP)
Phs
Volts
Amps
Motor
RPM
Speed
18"
1/15
1
115
0.9
1,400
Variable 4,000
CFM
Shipping
Weight
(lbs)
22
Warranty
5
• 2 year warranty on fan
10
15
Subject to Change without notice.
20
25
Printed in Canada -02/12
18” HORIZONTAL AIR FLOW FANS
Typical Layout for HAF Fans in 500’ Poultry Houses
80 ft.
80 ft.
10 ft. 10 ft.
80 ft.
80 ft.
Typical recirculating fan layout using six 18-inch axial vane fans, hung under ceiling along centerline of house.
Fan number and spacings may vary according to house conditions.
Typical Airflow for HAF Fans
Typical airflow pattern for axial vane recirculating fans.
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Ted: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Ted: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Ted: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada -02/12
18” HIGH VELOCITY FANS
Suitable for wet locations
Features
• Ceiling or wall mount high velocity fan
• 18” blades
• Commercial duty 3 speed pull chain circulating fan
• All metal construction
• 1/8 hp motor
• Three speed motor
• Epoxy coated OSHA guard
• 9’ heavy duty cord with cord wrap
• 110 volt cord set
• Steel wall (ceiling) mount assembly
• Suitable for wet locations
Performance Data & Specifications
MODEL
SIZE
H.P.
VOLTS
AMPS
Phs
RPM
SPEED
CFM
LF18HVW
18"
1/8
120
1.45/1.35/1.27
1
1290/960/760
Three
5700/4100/3200
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Ted: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Ted: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Ted: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada -02/11
CIRCULATING FANS
Canarm’s “CA” Circulating fans effectively cool large areas in Factories, Stores, Offices,
Restaurants and other Public Places.
General Information
Canarm’s CA circulating fans economically provide relief from summer heat by creating a
gentle air movement. They effectively cool large areas in factories, stores, restaurants and
other public places. These fans have a low RPM motor which allows them to operate quietly.
The Floor Pedestal type fans come with a sturdy base and are supported by an adjustable
tubular steel post which provides maximum stability. The Wall Mount fans are anchored with
a sturdy wall bracket. There is also an optional ceiling mount.
On all fan models, the fan assembly can be tilted on a swivel bracket to direct air stream
upwards or downwards. Available with oscillating motor on the pedestal and wall models.
CA Series
NOTE: CA FAN HEADS REPLACE
CFH FAN HEADS
LIMITED FAN KITS AVAILABLE
Fan Kits available only while quantities last.
Once stock is gone, we will be converting
to a fan head & accessory.
•
•
•
•
•
•
•
•
•
Features
Rugged, high performance model.
Available in 24” & 30” sizes.
1/4 HP, 3 speed, totally enclosed ball bearing motor with thermal overload protection.
Fan motor RPM - 1100/950/850.
Available with oscillating motor on the pedestal and wall models.
Heavy gauge aluminum, well balanced fan blades.
Air stream adjustable in all directions.
Complete with 10’, 120V grounded cord set.
Attractive powder coated front and rear guards, meet OSHA standards.
Performance Data
FAN HEAD MOUNTING ACCESSORIES SHOWN BELOW.
Model Number
Fan Size
Description
CFM
Volt
Amps
Shpg. Wgt.
QUICK REFERENCE
Use this table to make sure you order
the correct fan replacement parts.
OLD MODEL
Pedestal Fans
CA24P-C
24"
3 Speed
7100/6300/5300
115
2.7
60 lbs.
CA30P-C
30"
3 Speed
8300/7300/6300
115
2.7
83 lbs.
3 Speed
7100/6300/5300
115
2.7
40 lbs.
3 Speed Oscillating
7100/6300/5300
115
2.7
40 lbs.
3 Speed
8300/7300/6300
115
2.7
3 Speed Oscillating
8300/7300/6300
115
2.7
REPLACED WITH
PEDESTAL FANS - OSCILLATING
CA24POSC-C
CA30POSC-C
Heads Only
CA24OSC-C + CFKPB
CA30OSC-C + CFKPB
PEDESTAL FANS - NON OSCILLATING
CA24-C
24"
CA24OSC-C
CA30-C
30"
CA30OSC-C
CA24P-C
CA30P-C
CA24-C + CFKPB
CA30-C + CFKPB
50 lbs.
OLD MODEL
REPLACED WITH
50 lbs.
WALL FANS - OSCILLATING
CA24WOSC-C
CA30WOSC-C
Velocity Mapping Charts
CA24OSC-C + CFWB
CA30OSC-C + CFWB
WALL FANS - NON OSCILLATING
750
500
300
200
CA24W-C
CA30W-C
CA24-C + CFWB
CA30-C + CFWB
HIGH
100
CA24-C
CA30-C
These charts indicate the air distribution patterns of the CA fans.
They are a graphic illustration of air velocity in feet per minute.
HIGH
500
300
200
100
Mounting Accessories
MODEL
CFKPB
CFWB
CFCM
DF36X36
DESCRIPTION
KNOCK DOWN PEDESTAL BASE
WALL BRACKET
CEILING MOUNT (NON OSCILLATING FANS ONLY)
DOCK ARM
WEIGHT
36 LBS.
6 LBS.
9 LBS.
-
CFKPB
Subject to Change without notice.
CFCM
DF36X36
CFWB
Printed in Canada - 11/11
COMMERCIAL CIRCULATING FANS
PBKD/WMKD - COMMERCIAL CIRCULATING FANS
PBKD PEDESTAL FAN
Canarm’s high velocity commercial fans economically provide relief from summer heat
by creating a gentle air movement. Pedestal type fans come with a sturdy base and
adjustable pole. All fans have a 3 speed motor with industrial grade aluminum blades.
Features
•
•
•
•
•
•
•
WMKD WALL MOUNT FAN
Commercial duty circulating fans (Knock Down)
Sturdy aluminum blades
Standard OSHA guard.
3 speed
24” and 30” sizes
Motors have overload protection
Packaged in one box, complete with mounting accessories.
Specifications
FAN
SIZE
24"
MODEL NUMBER & WEIGHT (LBS)
PEDESTAL FAN
WEIGHT
WALL MOUNT FAN
WEIGHT
PBKD24-3SP
74 LBS.
WMKD24-3SP
38 LBS.
DESCRIPTION
H.P.
SUPPLY CFM
3 Speed
1/4
6600/5900/4900
1/4
6600/5900/4900
24"
PBKD24-OSC
78 LBS.
WMKD24-OSC
42 LBS.
3 Speed
Oscillating
30"
PBKD30-3SP
80 LBS.
WMKD30-3SP
46 LBS.
3 Speed
1/4
8300/7300/6300
49 LBS.
3 Speed
Oscillating
1/4
8300/7300/6300
30"
PBKD30-OSC
WMKD30-OSC
84 LBS.
CCU - COMMERCIAL CIRCULATING FANS
Canarm/LFI’s high velocity commercial fans economically provide relief from summer heat by creating
a gentle air movement. Pedestal type fans come with a sturdy base and adjustable pole. All fans have
a 3 speed motor with industrial grade aluminum blades.
Features
•
•
•
•
•
•
•
•
•
Commercial duty circulating fans (Knock Down).
20” stationary models.
Adjustable pedestal (54”-64”).
3 speeds.
Painted aluminum blades.
Standard OSHA guard.
Motors are thermally protected.
Complete with 10’, 120V grounded plug.
20” pedestal complete with wheel kit.
Specifications
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
MODEL
FAN SIZE
CCUP20
20"
DESCRIPTION
H.P.
SUPPLY CFM
WEIGHT
3 Speed Pedestal Fan
1/4
6200/5200/4200
47 BLS.
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 11/11
HIGH VELOCITY FLOOR/TABLE/WALL
CIRCULATING FAN
FLOOR/TABLE/WALL FAN
General Information
Canarmʼs high velocity commercial fans economically
provide relief from summer heat by creating a gentle air
movement.
All fans have 3 speeds and a silver painted finish with
industrial grade aluminum blades.
Features
•
•
•
•
•
•
•
•
•
•
Painted silver finish.
3 speed dial control.
Sturdy aluminum blades.
12ʼ, 14”, 18” and 20” sizes available.
Complete with 6ʼ 120V grounded cord set.
Convenient carrying handle/cord wrap.
Ergonomic tilt adjustment knobs.
Complete with wall mount bracket.
OSHA guard.
Easy assembly - no tools required.
WALL MOUNT BRACKET ASSEMBLY
Performance Data
HIGH SPEED
MEDIUM SPEED
MODEL
CFM
AMPS WATTS RPM
DB (A)
VELOCITY @
5ft (FT/MIN)
CFM
AMPS WATTS
LOW SPEED
RPM
DB (A)
VELOCITY @
5ft (FT/MIN)
CFM
AMPS
WATTS
RPM
DB (A)
VELOCITY @
5ft (FT/MIN)
HVF12F
1,500
0.88
71
1466
48
284
1,200
0.52
42
1275
42
254
800
0.37
30
966
40
191
HVF14F
2,000
1.02
81
1490
50
411
1,600
0.71
58
1302
50
369
1,100
0.55
46
986
45
227
HVF18F
3,800
1.90
146
1115
55
642
3,000
2.10
164
1279
60
549
2,100
2.86
223
1468
64
318
HVF20F
5,000
2.98
232
1437
62
866
4,000
2.21
164
1204
57
782
2,800
1.96
146
1050
53
675
Dimensions
HVF12F
BLADE
DIAMETER
12”
3 Speed Floor/Table Fan
15 3⁄4” W x 7 1⁄2” D x 15” H
1/10
WEIGHT
(LBS)
11
HVF14F
14”
3 Speed Floor/Table Fan
17 3⁄4” W x 7” D x 17” H
1/10
11
HVF18F
18”
3 Speed Floor/Table Fan
23 3⁄4” W x 8 1⁄2” D x 21 1⁄2” H
1/5
18
HVF20F
20”
3 Speed Floor/Table Fan
23 3⁄4” W x 10 1⁄4” D x 23” H
1/4
24
MODEL
DESCRIPTION
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
DIMENSIONS
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
H.P.
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 11/11
INDUSTRIAL CEILING FANS
Energy Savings
•
Cost Effective
•
Efficient
Ideally suited for circulating air in Industrial and Commercial Applications.
Canarm’s “CP” Fans help save energy year round.
In winter, ceiling fans are used to destratify hot air otherwise trapped at ceiling level (Hot air is moved back to floor level
where it keeps employees warm and comfortable). This can result in savings of up to 30% on heating costs.
In summer, Ceiling Fans run at higher speeds creating an evaporative cooling effect, keeping employees cool, and productivity higher.
Features
• “CP” series Industrial Ceiling Fans are available with 36”, 48” and 56” blade sweeps.
• All “CP” series fans have variable speed motors (all motors are thermally protected PSC type variable speed with permanently
lubricated bearings). When used in conjunction with our “MC” series speed controls the speed range is infinite.
• Painted steel blades with curved ends deliver maximum airflow over wide areas.
• All models except the CP56 c/w cord & plug are reversible (CP56 c/w cord & plug is downdraft only).
• Reversible motor provides both winter heat destratification and summer time cooling.
Approved
Performance Data & Specifications
Model Number
Color
Airflow
Fan
Size
Max Air Velocity Air Delivery
RPM 5' from fan
@ floor
CP36
White
Up/Downdraft
36”
380
750 ft/min
7,100 cfm
0.7
0.25
76
28
16”
12
CP48
White
Up/Downdraft
48”
320
700 ft/min
13,000 cfm
0.8
0.35
86
36
16”
16
CP56 F&R
White
Up/Downdraft
56”
310
660 ft/min
20,500 cfm
0.9
0.4
97
40
16”
17
CP56S (c/w
36" downrod)
White
Up/Downdraft
56"
310
660 ft/min
20,500 cfm
0.9
0.4
97
40
36"
19
CP56 C&P (c/w
cord & plug)
White
Downdraft
56"
310
660 ft/min
20,500 cfm
0.9
0.4
97
40
16"
18
CP56 BR
Brown
Up/Downdraft
56”
310
660 ft/min
20,500 cfm
0.9
0.4
97
40
16”
17
Subject to Change without notice.
Amps Low High Low Downrod
Shipping
High Amps Watts Watts Length Weight (Lbs.)
Printed in Canada - 02/11
INDUSTRIAL CEILING FANS
How to Choose a Fan
Ceiling fan choice and layout is based on ceiling height and the floor area of the building. As the height of the ceiling increases,
larger and more powerful fans are required to achieve destratification.
Figure 1
The floor air coverage of a fan will be greater the higher the ceiling of the building. This is
because of the natural cone shape of the air pattern produced by the fan. (See Figure 1)
(HPWP models have increased floor area coverage because of more powerful motors.)
Canarm provides two types of fans:
• The traditional ceiling fan, low cost, good performance, great for dry locations.
• The HPWP high performance, water resistant models - great for more demanding
applications with high moisture or greater air velocity requirements.
Use the following chart to choose the correct fan size/type and quantity to suit your
requirements. See the example below.
Ceiling Height
(feet)
Suggested
Fan Size
10 - 11
12 - 13
14 - 15
16 - 17
18 -19
20 - 21
22 - 25
26 - 30
CP36
Fan Floor Area Coverage (square feet)
Traditional
HPWP
600
800
950
1100
1300
1450
N/A
N/A
CP48
CP56
CP60
N/A
950
1150
1400
1600
1800
2250
2700
Example:
What size & how many fans would be required for a building that is 100 feet wide x 200 feet long & has as ceiling height of 16 feet?
•
•
•
•
By using the chart above, we see that a ceiling height of 16 feet requires a CP56 (56” fan).
Floor Area of the building = 100 feet wide x 200 feet long = 20,000 square feet.
From the chart, we know that the Fan Floor Area Coverage of the CP56 model is 1100 square feet at a 16 foot ceiling height.
Therefore, the number of fans required = Floor Area of building / Fan Floor Area Coverage:
20,000 square feet / 1100 square feet = 18 fans.
A typical layout for this building is illustrated below.
An additional fan should be used about 10 feet in front of each shipping door to act as an air curtain & reduce heating bills in
the winter.
20’
32’
32’
32’
32’
32’
20’
25’
25’
100 feet
25’
25’
200 feet
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 02/11
HIGH PERFORMANCE CEILING FANS
Heavy Duty
• High Performance • Maximum Output
Heavy Duty Motors and Bearings built for long life and Maximum output. Ideally suited for Agricultural Buildings.
Features
• Engineered and designed for spacious applications where
maximum floor coverage is required.
• Reversible motor for both winter heat destratification and summer
time cooling.
• All fans are sealed and suitable for high moisture applications.
• Designed for above average area coverage and cooling velocity.
Performance Data & Specifications
Model Number
Fan
Size
Max
RPM
Air Velocity
5' from fan
Air Delivery
@ floor
Amps
High
Watts
High
Downrod
Shipping
Length Weight (Lbs.)
CP48 HPWP
48"
352
700 ft/min
21,000 cfm
0.55
64
16"
18.02
CP56 HPWP
56"
319
660 ft/min
27,500 cfm
0.83
100
16"
24.00
CP60 HPWP
60"
292
650 ft/min
46,000 cfm
0.84
101
16"
24.65
Approved
CEILING FAN SPEED CONTROLS
Easy Installation
•
Infinite Speed Adjustments
•
Controls Multiple Fans
“MC” Control
“FRMC5” Reversible
• Available in 4 models: 3 amp, 5 amp,
10 amp and 15 amp.
• A slide switch is provided to change the
direction of the fan from updraft to
downdraft.
• The MC15 can operate up to 12 fans
on a single control.
• 5 amp rating for all reversible models
• Infinite speed adjustment
• Up to 4 fans can operate on a single
control.
• Minimum speed adjustment screw.
• Infinite speed adjustment
• Designed to fit a standard 3” x 5” electrical box.
• Minimum speed adjustment screw
• Mount in a dry location such as the control room.
• Designed to fit a standard 3” x 5” electrical box
• Mount in a dry location such as the control room.
Performance Data & Specifications
Model Number
MC-3
MC-5
MC-10
MC-15
FRMC5
Max # of Fans/control
2
4
8
12
4
Subject to Change without notice.
Variable Speed Operation
Manual
Manual c/w Forward/Reverse Switch
Power Supply
Ampere Rating
120V/1/60HZ
2.5
5.0
10.0
15.0
5.0
Approved
Printed in Canada - 02/11
HIGH PERFORMANCE CEILING FANS
How to Choose a Fan
Ceiling fan choice and layout is based on ceiling height and the floor area of the building. As the height of the ceiling increases,
larger and more powerful fans are required to achieve destratification.
Figure 1
The floor air coverage of a fan will be greater the higher the ceiling of the building. This is
because of the natural cone shape of the air pattern produced by the fan. (See Figure 1)
(HPWP models have increased floor area coverage because of more powerful motors.)
Canarm provides two types of fans:
• The traditional ceiling fan, low cost, good performance, great for dry locations.
• The HPWP high performance, water resistant models - great for more demanding
applications with high moisture or greater air velocity requirements.
Use the following chart to choose the correct fan size/type and quantity to suit your
requirements. See the example below.
Ceiling Height
(feet)
Suggested
Fan Size
10 - 11
12 - 13
14 - 15
16 - 17
18 -19
20 - 21
22 - 25
26 - 30
CP36
Fan Floor Area Coverage (square feet)
Traditional
HPWP
600
800
950
1100
1300
1450
N/A
N/A
CP48
CP56
CP60
N/A
950
1150
1400
1600
1800
2250
2700
Example:
What size & how many fans would be required for a building that is 100 feet wide x 200 feet long & has as ceiling height of 16 feet?
•
•
•
•
By using the chart above, we see that a ceiling height of 16 feet requires a CP56 (56” fan).
Floor Area of the building = 100 feet wide x 200 feet long = 20,000 square feet.
From the chart, we know that the Fan Floor Area Coverage of the CP56 model is 1100 square feet at a 16 foot ceiling height.
Therefore, the number of fans required = Floor Area of building / Fan Floor Area Coverage:
20,000 square feet / 1100 square feet = 18 fans.
3%
3%
3%
3%
3%
3%
A typical layout for this building is illustrated below.
An additional fan should be used about 10 feet in front of each shipping door to act as an air curtain & reduce heating bills in
the winter.
50 ft.
75 ft.
75 ft.
50 ft.
25 ft.
50 ft.
50 ft.
50 ft.
50 ft.
25 ft.
5 paddle fans in brood chamber
CANARM LTD. - Corporate Office
2157 Parkedale Ave., Brockville, ON
Canada K6V 5V6
Tel: (613) 342-5424 Fax: 1-800-263-4598
CANARM LTD. - USA Warehouse
808 Commerce Park Drive
Ogdensburg, New York, USA 13669
Tel: 1-800-267-4427 Fax: 1-800-263-4598
Arthur Manufacturing Facility
#7686 Concession 16, RR 4 Arthur, ON
Canada N0G 1A0
Tel: (519) 848-3910
Fax: (519) 848-3948
Web Site: www.canarm.com
E-Mail: [email protected]
Subject to Change without notice.
Printed in Canada - 02/11
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement