Original instructions SIRe Competent Fan Heater Water With quick guide SIReFC SE .... 2 GB .... 17 DE .... 33 FR .... 50 ES .... 6´7 IT NL .... 101 NO .... 118 PL .... 134 RU .... 150 .... 84 For wiring diagram, please see last pages GB SIRe Competent Fan Heater Water Quick guide/start up Enter ID/Operation without control unit Check that all constituent parts are present (see section Constituent parts). The control system can control one or more units in parallel (max 9). Each unit must get a unique ID number (1-9) which is set in the ID selector of the PC board. E.g. Unit 1: ID=1, unit 2: ID=3 If the external control for some reason has not been installed the unit can still be run temporarily. The ID selector is then set to mode 0 see the image below. The function is half speed and heating is on. When the ID number must be changed the unit must be disconnected from power. Advice about location PC board HUB SIReC1X is installed close to the unit. Control unit SIReUA1 has an integrated room temperature sensor and is installed so that it is easily accessible to the user. RJ12 (6p/6c) modular cables, which are available in different lengths, are used to connect the PC board and the control unit. Longer cables are available as options. Maximum cable lengths see section Options. To prevent unauthorised people from accessing the Control unit it can instead be placed in another area and an external room sensor, SIReRTX (option), can be installed in the premises to sense the correct temperature. Connect the system In control board base SIReB1(X) the unit is connected further with RJ12 (6p/6c) modular cable if several units are to be connected in parallell. The actuator for water control is connected to PC board SIReB1(X). Control board Base SIReB1(X) in/at the unit and control unit SIReUA1 are connected by PC board HUB SIReC1X with RJ12 (6p/6c) modular cables, after the other units are powered up. For fixed installation requirements, remove the supplied cable and plug. Perform the installation in accordance with applicable regulations. 4 3 3 4 5 6 2 7 2 7 8 1 8 0 9 0 9 Each unit should have a unique ID on its SIReB1X card. To run the unit temporarily without external control select mode 0. Start up System supplied with power. At the first start up, the start-up wizard is run and the basic settings are made. Fan and heating steps are tested through the test program. Then a status window is displayed. At the first start up alarm and error codes can occur, these will usually be reset without actions. Start-up wizard 1 Start-up wizard 5 Set language English Start-up wizard Function test Start test Skip test Screen function test 2 Start-up wizard Start-up wizard Set temp. unit Fan step 1-5 Heating step off-1 °C °F 3 Start-up wizard 6 Set date 2011-05-28 4 Start-up wizard Set time 24h format Checking system... Start-up wizard Function test Test completed Restart test YYYY-MM-DD 14:07 2 6 1 Wiring diagrams The wiring diagrams are in a separate section at the end of this manual. When external PC board Base SIReB1X is used, wiring between the PC board base and the unit must be done. Please see separate manual for SIReB1X. 5 7 Start-up wizard Start-up finished Proceed Restart wizard SIRe Competent Fan Heater Water GB Contents Quick guide/start up Advice about location Connect the system Wiring diagrams Enter ID/Operation without control unit Start up 17 17 17 17 17 Constituent parts SIReFC19 Operating modes Operating modes 22 Control unit SIReUA1 Overview23 Statuswindow23 Main menu 24 Current settings Temperature settings 24 Fan control 24 Summer/Winter24 24 System on/off Installer menu 24 Installer menu Installer status screen Week program Fan settings Heating settings Filter guard settings External control (BMS) General settings Service menu 25 25 26 26 27 27 28 28 Alarm and error codes Displaying alarm and error codes Reset alarm Overheat protection Power failure Frost protection function 29 29 29 29 29 Wiring diagrams, see last pages 3 GB SIRe Competent Fan Heater Water Constituent parts SIReFC Integrated in fan heater X5 C2 SIReUA1, control unit Competent and Advanced Wall unit cover SIReC1X, PC board HUB Competent SIReCC, modular cable X4 C1 X3 ROOM ACTUATOR 230V SIReB1/B2, integrated PC PE N L SUPPLY 230V SIReIT, internal temperature sensor Dimensions constituent parts 4 Type Description SIReUA1 SIReB1 SIReIT SIReC1X SIReCC603 SIReCC605 Control unit Competent and Advanced Integrated PC board Base Internal temperature sensor PC Board HUB Competent Modular cable RJ12 (6/6) Modular cable RJ12 (6/6) HxWxD [mm] 120x70x35 L [m] 1 202x139x50 3 5 GB SIRe Competent Fan Heater Water Option SIReRTX, external room temperature sensor SIReUR, kit for recessed installation SIReCJ4, joint piece SIReCJ6, joint piece SIReCC, modular cable Type RSK-no. E-no. Description SIReRTX SIReUR* SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 SIReCC615 SIReCC403 SIReCC405 SIReCC410 SIReCC415 673 09 22 673 09 21 87 510 12 87 510 11 673 09 23 673 09 24 673 09 25 673 09 26 673 09 27 673 09 28 673 09 29 673 09 30 87 510 13 87 510 14 87 510 15 87 510 16 87 510 17 87 510 18 87 510 19 87 510 20 External room temperature sensor Kit for recessed installation Joint piece for two pcs. RJ11 (4/4) Joint piece for two pcs. RJ12 (6/6) Modular cable RJ12 (6/6) Modular cable RJ12 (6/6) Modular cable RJ12 (6/6) Modular cable RJ12 (6/6) Modular cable RJ11 (4/4) Modular cable RJ11 (4/4) Modular cable RJ11 (4/4) Modular cable RJ11 (4/4) HxWxD [mm] 70x33x23 114x70x50 L [m] 3 5 10 15 3 5 10 15 *) See separate manual. Max. cable lenghts • Modular cabel RJ12 (6p/6c) between SIReUB1 and SIReB1(X): max 50 m. • Modular cable RJ12 (6p/6c) between SIReC1X and SIReB1(X): max 10 m • Modular cabel RJ12 (6p/6c) between two SIReB1(X): max 50 m. • Modular cabel RJ11 (4p/4c) to room sensor SIReRTX: max 20 m. Total cable length permitted in the system is a maximum of 300 m. 5 GB SIRe Competent Fan Heater Water Water control - valve kit VOS Water control - option VOSP VAT, adjustment tool for valve package. VOT SD230 TRVS Type RSK-no. Description Connection VOS15LF VOS15NF VOS20 VOS25 VOSP15LF VOSP15NF VOSP20 VOSP25 VOT15 VOT20 VOT25 VAT 673 09 35 673 09 36 673 09 37 673 09 38 673 09 43 673 09 44 673 09 45 673 09 46 On/off On/off On/off On/off Pressure independent Pressure independent Pressure independent Pressure independent Three way valve and actuator on/off Three way valve and actuator on/off Three way valve and actuator on/off Adjustment tool for valve package DN15 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN15 DN20 DN25 6 482 98 30 SIRe Competent Fan Heater Water GB Operating modes Operating modes Control is based on the four operating modes: •Auto •Thermostat / Manual fan •Thermostat / Automatic fan •Manual Auto When the set point value is undercut by 0.5 K the fan starts at speed 1 and the valve motor starts to open stepless. If a fully open valve is not sufficient to maintain the temperature, the fan control increases to a max of step 4. The difference between the setpoint value and the room temperature for the fan to increase one step is set under Heating step diff., see Installer menu > Settings heating > Heating step diff. When Auto is active the fan speed and heating cannot be changed in the status window. Thermostat / Manual fan The thermostat just controls the heating and the fan runs continually. The fan speed is set manually. The fan symbol is marked in the status window, select desired speed with the rotary dial and confirm. Thermostat / Automatic fan The thermostat controls both the heating and the fan. The fan speed is set manually in the status window. [Installer menu > Settings fan > Fan mode.] Manual The fan speed and heating is set manually in the status window. Heating can be set to 3 steps (33%, 66% and 100%). Heating is blocked by the outdoor temperature, see: [Installer menu > Settings heating > Outdoor temp. limit] 7 GB SIRe Competent Fan Heater Water Control unit SIReUA1 Overview Statuswindow (Auto mode) IN 19.0 °C Statuswindow Statuswindow (Manual mode) IN Back arrow 19.0°C Forward arrow Fan speed step Rotary dial Heating step Meny Week program Day Alarm Red led Run signal Green led Week program Night AV Week program Out of operation Explanations Statuswindow Statuswindow For thermostat/manual control of the fan and heating the relevant symbol is marked in the status window with the forward arrow. Steps can then be set, confirm with the forward arrow. For description, see section Operating modes. Press forward arrow to enter the main menu. The display shows the prevailing room temperature, fan and heating step, door status and day/night mode or Off when the week program is used. This also displays whether the control is set to auto mode or manual mode. Forward arrow Confirm selection and proceed. Rotary dial Scroll between alternatives Back arrow Go back. After three minutes the control unit goes back to displaying the status window. 8 GB SIRe Competent Fan Heater Water Main menu Summer/Winter Current settings To permit or block heating. Heating is permitted in winter mode. Summer mode is displayed with a crossed out heating symbol in the status window. Displays set room temp, high speed limit, Speed closed door, Summer / Winter and week program status. Main menu Current settings Current settings Temperature settings Fan control Room temp. day Room temp. night High speed limit Summer/Winter Week program 20°C 18°C Step 5 Winter No program Main menu Main menu>Summer/Winter Fan control Summer/Winter System on/off Summer/Winter Winter • Factory setting Summer/Winter: Winter (Summer - heat off) Temperature settings Set the desired room temperatures to apply for day respectively night mode (room temperature night is used for week program/ night reduction). Main menu Current settings Temperature settings Fan control Main menu>Temperature settings Room temp. day Room temp. night Factory setting Room temp. day: 20°C (5 – 35°C) Room temp. night: 18°C (0 – 20°C) System on/off Switch the whole unit off manually. In Off the display goes out; as soon as a button is pushed the display lights and shows System on/off. To activate the unit again select On. The unit’s safety functions are still active when the system is switched off, which means that the fan can continue to run for a moment after mode Off has been selected. Main menu Main menu>System on/off Summer/Winter System on/off Installer menu System on/off ON • Fan control Possibility of limiting high speed mode. In Auto mode (see fan settings) the fan high speed limit is set automatically to step 4 in order to keep the sound level down. If you wish to further restrict the fan control it can be done here. Main menu Temperature settings The installer menu is at the bottom of the main menu, this is password protected. See Installer menu in this manual. Main menu Main menu>Installer menu Summer/Winter System on/off Enter password Installer menu Fan control Summer/Winter Main menu>Fan control Main menu>Fan control High speed limit High speed limit • Installer menu 0 0 0 0 (See manual) Step 5 Factory setting High speed limit: 5 (1-5) 9 GB SIRe Competent Fan Heater Water Installer menu To enter the Installer menu, code 1932 is entered. Select the digits using the rotary dial and confirm using the forward arrow. To check which days a certain program is active, select a week day by pressing the forward arrow, the program is marked and those days that the program is used will be underlined, switch between the programs for a particular day using the rotary wheel. Main menu Main menu>Installer menu Check program Summer/Winter System on/off Enter password Mon Tue Wed Thu Fri 0 0 0 0 (See manual) Installer menu Installer status screen Check the settings. The installer status screen consists of three pages with settings, scroll using the rotary dial. To add program step, select New program step. Confirm your selection with the forward arrow. Select Day, Night or Off (if the unit should not be in operation), set the time for switch on and then for which days the program applies, then go to End to finish. >Installer menu>Week program >Installer menu >Installer status screen Installer status screen Week program Fan settings Functionality mode Program Sat Sun 08:00 Day (1) 18:00 Night (2) Comp. FH42°C FF 002 FF FF Week program on/off New program step Check program New program step 7/16 Mode Day 00:00 Tue 10:45 Mon Tue Wed Thu Fri Tue 10:45 Sat Sun Tue 10:45 Mon Tue Wed Thu Fri Week program End Make settings for week program. Installer status screen Week program Fan settings >Installer menu>Week program A basic program is pre-entered in SIRe. Mon-Fri Day from 08:00, Night from 18:00 Sat Day from 10:00, Night from 16:00 Sun Day from 11:00:00, Night from 14:00 To check which program is set for a particular day, select Check program and then switch between the days using the rotary dial. New program step Check program Change program Check program Mon Tue Wed Thu Fri 08:00 Day (1) 18:00 Night (2) Sat Sun Check program Change program Remove program Change program Mon Tue Wed Thu Fri 1. 08:00 2. 18:00 3. 10:00 4. 16:00 Day Night Day Night 00:00 Sat Sun Tue 10:45 Mon Tue Wed Thu Fri Tue 10:45 Sat Sun Tue 10:45 Mon Tue Wed Thu Fri End Sat Sun Tue 10:45 The program steps that should not apply are removed in Remove program. One or all program steps can be removed in the menu. To return to the factory set basic program, select Reset all. >Installer menu>Week program Check program Change program Remove program 10 Tue 10:45 A new program step does not replace a set time for Day for example, but you can instead select to change a program step. To change a program step, select Change program. >Installer menu >Installer menu>Week program Sat Sun Remove program Remove single Remove all Reset all GB SIRe Competent Fan Heater Water Week program is activated by selecting On, under Week program on/off. In On-mode, a sun, moon or Off in the Status window appears to indicate day, night respectively Offfunction. >Installer menu>Week program >Installer menu>Week program Week program on/off New program step Check program • Heating step diff. When the temperature falls below the set point value the fan speed increases (the high speed limit is position 4). Which temperature difference the speed is to be increased by a step for is selected in Heating step diff. Week program on/off OFF Fan settings Make settings for fan mode (see also Operating modes section). >Installer menu Week program Fan settings Heating settings >Installer menu>Fan settings >Installer menu>Fan settings Fan mode Fan mode • Auto >Installer menu>Heating settings >Installer menu>Heating settings Heating step diff. Sensor calibration Control range limit • Heating step diff. 1.0 K Factory setting Heating step diff.: 1.0 K (-10 K – 10 K) Sensor calibration If the sensor displays the wrong values these can be calibrated. Some display errors may occur, but this is primarily due to the location (cold/hot surfaces etc). The value + or – adds to or subtracts from the measured value (for example +2K gives an increase of the displayed value of 2 degrees). >Installer menu>Heating settings>Sensor calibration >Installer menu>Fan settings Fan mode Thermostat Manual fan >Installer menu>Heating settings Heating step diff. Sensor calibration Control range limit >Installer menu>Fan settings Fan mode Thermostat Auto fan >Installer menu>Fan settings Room temp. sensor Outdoor temp. sensor >Installer menu>Heating settings>Sensor calibration Room temp. sensor • 0.0 K Factory setting Room temperature sensor: 0.0 K (-10 K – 10 K) Fan mode • Manual Factory setting Fan mode: Auto (Thermostat / Manual fan, Thermostat / Automatic fan, Manual) Heating settings Make settings for heating. >Installer menu Fan settings Heating settings Filter guard settings Control range limit The maximum room temperature that a user can select is limited to between 5 – 35°C. >Installer menu>Heating settings Heating step diff. Sensor calibration >Installer menu>Heating settings Control range limit • 35°C Control range limit Factory setting Control range limit temperature: 35°C (5 – 35°C) 11 GB SIRe Competent Fan Heater Water Filter guard settings External control (BMS) Filter alarm alarms when the set fixed run time has been exceeded. BMS functions can be activated under External control. Activate External on/off (5-30V AC/DC from BMS) or 0-10V fan control by selecting On under the respective one. See diagram on next page and Connecting external control. >Installer menu Heating settings Filter guard settings External control Filter timer setting Under Filter timer setting, set the desired run time to between 50 and 9950 hours. >Installer menu>Filter guard settings Filter timer on/off Filter timer setting Last filter change >Installer menu>Filter guard settings • 1500 h >Installer menu Factory setting Filter timer setting: 1500 h (50 - 9950 h) Filter timer on/off Filter alarm is activated by selecting On, under Filter timer on/off. >Installer menu>Filter guard settings Filter timer on/off Filter timer setting Last filter change Factory setting Filter timer on/off: Off (On) Last filter change To check the number of run time hours since the last filter replacement, select Last filter change. The time is reset when the filter alarm is reset. If the time is to be reset before the alarm has gone, switch the filter timer on and off. >Installer menu>Filter guard settings Filter timer on/off Filter timer setting Last filter change 12 >Installer menu>External control Filter timer setting >Installer menu>Filter guard settings Last filter change 0h Filter guard settings External control General settings External on/off 0-10V fan control >Installer menu>External control External on/off 0-10V fan control SIRe Competent Fan Heater Water GB 8,4 5 7,0 4 5,6 3 4,2 2 2,8 1 1 7,4 6,0 4,6 3,2 2 8,8 3 4 5 6 7 8 9 10 11 [V] Diagram: Fan step at incoming 0-10V DC voltage level, 5 step 7,2 3 5,0 2 7,6 2,8 1 5,4 1 2 3,2 3 4 5 6 7 8 9 10 11 General settings Possibility of making general settings that are also in the Start-up wizard and execute user reset. [V] Function test To test the fan and heating steps, run the function test. >Installer menu External control General settings Support menu >Installer menu>General settings Function test Start test Skip test Change the date, time, language and temperature unit. >Installer menu>General settings Set date Set time Set language Function test User reset Fan step 1-5 Heating step off-1 >Installer menu>General settings User reset User reset (Room temp. day resp. night, high speed limit, speed closed door, door, Summer / Winter) to factory setting. >Installer menu>General settings >Installer menu>General settings >Installer menu>User reset Execute user reset? No Yes Function test Test completed Restart test Service menu The service menu is password protected and is used for support in contact with Frico or authorised installer. 13 GB SIRe Competent Fan Heater Water Alarm and error codes SIRe has different alarms and error codes for safe and problem free operation. If alarms or error codes have been indicated these must be reset in order to return to normal operation, for example activating the heating again. Fan mode is active even when, for example, the over heating alarm has been indicated. Displaying alarm and error codes In event of alarm or error the alarm/error code is shown in the status window. In event of alarm/error code the unit it applies to is displayed. See Table - Alarms and Table – Error codes. Reset alarm Note! Before resetting, check that the fault is rectified and there is nothing to prevent the unit from being recommissioned! When the fault is rectified, the alarm is reset by pressing the forward arrow and selecting Reset alarm and then confirm. If several units give an alarm at the same time, the fact that there are several alarms is indicated, but only one is shown in the display. By resetting that alarm the next alarm can be read. At the first start up alarm and error codes can occur, these can usually be reset without action. Overheat protection The overheat protection is designed to limit the temperature of the heater to a maximum of +90° C. If the temperature should exceed 95°C e.g. in the event of a faulty valve or actuator, the fan starts to speed up to keep the temperature down. At the same time there is an overheating alarm A2. At internal temperatures of +100°C the fan runs at maximum speed. If the unit cools, heating is automatically reengaged. The alarm remains in the control unit’s display. If the unit overheats twice within an hour, the fan operates until the alarm is reset. 14 Power failure Note that in case of power failure the time settings need to be checked, if the time is not set correctly week program will be affected. Frost protection function Only applies to units with internal sensor. The frost protection function is intended to prevent the water coil from freezing. If the internal temperature falls below +5 °C frost protection alarm A3 is given, the valve actuator opens and the fan stops. Note! In event of repeated alarms, overheating alarms and frost protection alarms, carry out a thorough check and if the fault cause cannot be found contact authorised installer or Frico. SIRe Competent Fan Heater Water GB Table - Alarm Alarm A1 Motor alarm AA2 Over heating alarm Cause Action Thermal switch has deployed. One or several motors have overheated. (Only units with withdrawn thermal switches.) Check that nothing is obstructing the unit’s air intake and exhaust. When the overheated motor has cooled the thermal switch shuts again and the alarm can be reset. At repeated alarms, check the motors, replace damaged motors. The temperature in the unit has exceeded the alarm limit for overheating. Check that nothing is obstructing the unit’s air intake and exhaust, the function of the actuator and valve, flow temperature and internal temperature sensor. A3 Frost protection alarm The temperature in the unit has fallen below the alarm limit for frost protection. (Only applies to units with internal unit temperature.) Make sure that the ambient temperature where the unit is installed exceeds +5°C. Check the flow temperature, the flow of hot water and the function of the actuator and valve. In event of an alarm there a risk that the battery is damaged, check carefully for leakage and replace the battery if damaged. A4 Filter alarm Fixed run time before the filter alarm has been reached. Replace or clean the filter, adjust any alarm time based on how dirty the filter was and reset the alarm. A5 Ext. alarm External alarm input on SIReC1X has been activated. Check the external alarm. 15 GB SIRe Competent Fan Heater Water Table - Error codes Error code Cause Action E1 Communication SIReB1(X) has no contact with SIReC1X. Check connection between the boards. Replace any modular cables. E2 ID Error Two or more SIReB1(X) have the same ID-number. Interrupt the current and select different ID numbers for all SIReB1(X) in the system. E3 ID Error One or more SIReB1(X) do not have programs. Contact Frico for support. Fault on or missing external room sensor SIReRTX connected to SIReB1(X). Always disconnect the power when connecting or disconnecting sensors. Check connection of the sensor. Fault on or missing internal sensor in the unit. Check connection of the sensor. If there is no sensor, contact Frico for support. E4 Room sensor error E8 Internal sensor faults E10 ID Error Two or more SIReB1(X) in the system have different programs. Contact Frico for support. E12 Room sensor error Fault on or missing external room sensor SIReRTX connected to SIReA1X. Always disconnect the power when connecting or disconnecting sensors. Check connection of the sensor. E20 Communication Control unit SIReUA1 has no contact with SIReC1X. Check the connection. Replace any modular cables. E21 Room sensor error Error in the internal room sensor in the control unit SIReUA1. E23 16 Soft ware error Contact Frico for support. Check the connection between SIReUA1 and SIReC1X. Replace any modular cables. If the error is not rectified SIReUA1 must be replaced. GB SIRe Competent Fan Heater Water Connecting external control - including BMS functions SIReC1X COM 1 External on/off 5-30V AC/DC External signal activates the unit. Set parameter: >> Installer menu > External control > External On/Off= On 1516 + - Not used 17 18 1112 + - Alarm outgoing (BMS) (potentialfree switch, max 3A, 230V) Outgoing alarm indication. Always active. Closed = buzzer alarm Open = no alarm 19 20 External speed control 0-10V DC Controls the fan speed in steps (see diagram section External control (BMS). Set parameter: >> Installer menu > External control > 0-10V Fan control = On 9 10 External alarm IN (potential free contact) Input for external alarm. Closing gives alarm. 7 8 External night reduction on/off (potential-free switch) Closes to activate the night reduction function. Always active. 19 20 ALARM OUT (BMS) ROOM Not used 15 161718 External ON/OFF 1112 + - Ext. speed ctrl. 0-10V DC IN COM 2 External alarm IN 7 8 9 10 External night reduction 17 SIRe Competent Fan Heater Water Wiring diagram - Competent SIRe Competent Fan Heater Water Wiring diagram - Competent - parallel connection Tel: +46 31 336 86 00 [email protected] www.frico.se For latest updated information and information about your local contact: www.frico.se Art no: E4440, 2013-04-29 HH/SÅ/SÄ Main office Frico AB Box 102 SE-433 22 Partille Sweden
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement