MODEL: MS Plug-in Signal Conditioners M-UNIT 0: Specify voltage (See OUTPUT SPECIFICATIONS) PARAMETER GENERATOR [2] POWER INPUT Functions & Features • Providing a constant DC signal • Setpoint monitoring with LCD meter • Isolation up to 2000 V AC • High-density mounting AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC V: 48 V DC P: 110 V DC Typical Applications • Various parameter settings for computers and DCS’s 50 (1.97) 80 (3.15) 127 (5) mm (inch) MODEL: MS–[1]–[2][3] ORDERING INFORMATION • Code number: MS-[1]-[2][3] Specify a code from below for each [1] through [3]. (e.g. MS-A-B/E) • Special output range (For codes Z & 0) [1] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 100 Ω min.) 4: 0 – 10 V DC (Load resistance 1000 Ω min.) 5: 0 – 5 V DC (Load resistance 500 Ω min.) 6: 1 – 5 V DC (Load resistance 500 Ω min.) 4W: -10 – +10 V DC (Load resistance 2000 Ω min.) 5W: -5 – +5 V DC (Load resistance 1000 Ω min.) http://www.m-system.co.jp/ [3] OPTIONS Signal Indicator blank: Without /E: With front-mounted LCD meter GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Housing material: Flame-resistant resin (black) Isolation: Output to power Output adjustment: Multi-turn screwdriver (front) Monitor jacks: Output 0 – 10 V for 0 – 100 % setpoint (deleted with option /E) Monitor jack diameter: 2 mm (.08") LCD meter: 0.1 % increments OUTPUT SPECIFICATIONS • DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. • DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V INSTALLATION Power input •AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA •DC: Operational voltage range: rating ±10 %, or 85 – 150 V for 110 V rating (ripple 10 % p-p max.) MS SPECIFICATIONS ES-1651 Rev.7 Page 1/3 MODEL: MS approx. 2.5 W (100 mA at 24 V) Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 350 g (0.77 lbs) PERFORMANCE in percentage of span Setting accuracy (monitor jacks): ±0.1 % Setting accuracy (digital display): ±0.1 % ±1 digit Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (output to power to ground) EXTERNAL VIEW ■ STANDARD TYPE: MONITOR JACKS + ■ OPTION/E: LCD METER Monitor LCD Meter Setpoint Adj. Setpoint Adj. Front Cover (open) Front Cover (open) – EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) CLAMP (top & bottom) 20 (.79) 7.8 (.31) 107 (4.21) 127 (5) 5 4 3 7 8 1 2 2–4.5 (.18) dia. MTG HOLE 15 (.59) deep 8–M3.5 SCREW 50 (1.97) 6 80 (3.15) 80 (3.15) 35.4 (1.39) DIN RAIL 35mm wide 40 (1.57) [3.3 (.13)] 50 (1.97) • When mounting, no extra space is needed between units. http://www.m-system.co.jp/ MS SPECIFICATIONS ES-1651 Rev.7 Page 2/3 MODEL: MS SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM * Sensing Voltage Generator Low Drift Amplifier 3 Output Driver 1 + OUTPUT 2 – 4 Setpoint Monitor 5 6 + 7 U(+) POWER – 8 V(–) Base Socket *Option/E. Setpoint monitor circuit and monitor jacks are deleted when Option/E is selected. Specifications are subject to change without notice. http://www.m-system.co.jp/ MS SPECIFICATIONS ES-1651 Rev.7 Page 3/3
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement