DATA SHEET
CROSS TECHNOLOGIES, INC.
Rev. C
10/29/08
2016-05 Downconverter, 950 - 1525 MHz, 140 MHz IF
The 2016-05 Downconverter converts 950 to 1525 MHz to 140 MHz in 1 MHz steps with low group delay and flat frequency response.
Synthesized local oscillators (LO) provide frequency selection. Multi-function push button switches select the input frequency, gain, and
other parameters. Front panel LEDs provide indication of DC power, PLL alarm or Remote operation. Gain is adjustable manually
(MGC) over a 0 to 50 dB range. The frequency and gain are remotely selectable. Parameter selection and frequency and gain settings
appear on the LCD display. Connectors are Type F female for the RF, and BNC female for the IF and optional external 10 MHz
reference input and output (option E). Other connector options are available. LNB +24 VDC (option L) and 10 MHz reference (option
E) can be inserted on the RF lines. The 2016-05 is powered by a 100-240 ± 10% VAC power supply, and is contained in a 1 3/4” X 19 “
X 16” rack mount chassis.
MODEL 2016
DOWNCONVERTER
F=1525
G=+25.0
MENU
CROSS TECHNOLOGIES INC.
EXECUTE
ALARM
REMOTE POWER
Front Panel
EQUIPMENT SPECIFICATIONS*
IInput Characteristics (RF)
Impedance/Return Loss 75 /12 dB
120 MHz
LP
Frequency
950 to 1525 MHz
.95
140
to
var
MHz
Noise Figure, max.
15 dB (max gain)
1.525
atten
OUT
GHz
Input Level Range
-70 to -20 dBm
EXT
IN
10MHz*
10MHz*
Input 1dB compression
-15 dBm
+24VDC*
INT
Output Characteristics (IF)
10MHz
Impedance/Return Loss 75/18 dB
Frequency
140 ± 36 MHz
F=1450 G=+25
CONTROLLER
*OPTIONAL
Output level/max linear
-20dBm / -10dBm
Output 1 dB compression -5 dBm
Block Diagram
Channel Characteristics
Gain range (adjustable) 0.0 to +50.0 dB, 1dB steps
Image Rejection
> 50 dB, min.
Frequency Response
±1.5 dB, 950 to 1525 MHz ; ± 0.5 dB, 72 MHz BW
Spurious Response
< -50 dBc, in band
Group Delay, max
0.0035 ns/MHz2 parabolic; 0.025 ns/MHz linear; 1 ns ripple
Frequency Sense
Inverting or Non-inverting (user selectable)
Available Options
Synthesizer Characteristics
E - External 10 MHz ref input & output
Frequency Accuracy
± 1.0 ppm internal reference (±.01 ppm, option H)
w/ RF insertion
Frequency Step
1.0 MHz minimum
L - LNB Voltage, +24VDC, 0.4 amps
10 MHz In/Out Level
3 dBm ± 3 dB (option E)
H - High Stability (±0.01) Internal Ref
Phase Noise @ Freq
100 Hz
1kHz
10kHz
100kHz
1 MHz
Q - RS485 Remote Interface
dBC/Hz
-70
-70
-80
-90
-105
T - Temperature Sensor
Controls, Indicators
Connectors/Impedance
Freq/Gain Selection
direct readout LCD; manual or remote selection
B - 75 BNC (RF), 75 BNC (IF)
Power; Alarm; Remote
Green LED; Red LED; Yellow LED
C - 50 BNC (RF), 75 BNC (IF)
Remote
RS232C, 9600 baud (RS485, option Q)
D - 50 BNC (RF), 50 BNC (IF)
Other
N - 50 N-type (RF), 75 BNC (IF)
RF, IF Connectors
Type F (female), BNC (female)
M - 50 N-type (RF), 50 BNC (IF)
10MHz Connectors
BNC (female), 50/75 (option E)
Alarm/Remote Connector DB9 (female) - NO or NC contact closure on Alarm
Size
19 inch, 1RU standard chassis 1.75”high X 16.0” deep
Power
100-240 ±10% VAC, 47-63 Hz, 45 W max
*10˚C to 40˚C; Specifications subject to change without notice
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road, Alpharetta, Georgia 30005
770-886-8005, FAX 770-886-7964
www.crosstechnologies.com
">