EU Declaration of Conformity
Product:
Name and address of the manufacturer:
Rockwell Automation, Inc.
1201 South 2 nd Street
Milwaukee, WI 53204
U.S.A.
30mm Emergency Stop Buttons
Name and address of the authorised representative:
Rockwell Automation B.V.
Rivium Promenade 160
2909 LM Capelle aan den Ijssel
The Netherlands
This declaration of conformity is issued under the sole responsibility of the manufacturer.
Object of the declaration: Allen-Bradley 800H and 800T Series
(reference the attached list of catalogue numbers)
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:
2006/95/EC & 2014/35/EU Low Voltage Directive (LVD)
References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared:
EN 60947-5-1:2004+A1:2009
EN 60947-5-5:1997 + A1:2005 +
A11:2013
EN ISO 13850:2008
Additional information:
Year of CE Marking (LVD):
Person authorised to compile the technical file (MD):
Product Safety Function (MD):
Low-voltage switchgear and controlgear – Part 5-1: Control circuit devices and switching elements – Electromechanical control circuit devices
Low voltage switchgear and controlgear – Part 5-5: Control circuit devices and switching elements – Electrical emergency stop devices with mechanical latching function
Safety of machinery – Emergency stop – Principles for design
1995
Authorised representative (see details above).
Direct-opening action with normally-closed contacts for emergency stop button devices
Signed for and on behalf of the above named manufacturer:
Place and date of issue: Milwaukee, WI USA 15-Feb-2016
Name, function: Daniel L. Nachtigall, Technical Leader – Product Certification Engineering
Signature:
Document Control Number: LCC-0213-B-EN 1 / 5
Catalogue number Series 1 Description
800T(C)-TFX**6*
800T(C)-TFX***R*
800H(C)-TFRX*T6*
800H(C)-TFRX*TR*
800T(C)-FX*6*
800H(C)-FRX*6*
Non-illuminated trigger action emergency stop button per Nomenclature
Illuminated trigger action emergency stop button per Nomenclature
Non-illuminated trigger action emergency stop button per Nomenclature
Illuminated trigger action emergency stop button per Nomenclature
Emergency stop button per Nomenclature
Emergency stop button per Nomenclature
1) If no series number is given, then all series are covered
MODEL NOMENCLATURE
Non-Illuminated Trigger Action Emergency Stop Buttons:
1 2 3 4 5 6
1 Designates Product Line
800T – 30mm, metal operator
800H – 30mm, plastic operator
2 Designates Terminal Guard Option
Blank – Without terminal guard
C – With terminal guard
3 Designates Head Type
800T Head Options:
TFX – 45mm mushroom head
TFXJ – 60mm jumbo mushroom head
TFXJE – 60mm jumbo mushroom head with text
TFXL – 63mm metal head
TFXLE – 63mm metal head with text
800H Head Options:
TFRX – 45mm mushroom head
TFRXJ – 60mm jumbo mushroom head
TFRXJE – 60 mm jumbo mushroom head with text
T – Twist-to-release
K (followed by a one or two digit number) – Key release (available only with 800T-TFX head type)
5 Designates Cap Colour
6 – Red
6 Designates Contact Block Configuration
D4S or 3 – 1-NCLB self-monitoring contact block (800TC-XD4S)
D4V or Q – 1-NCLB Pentuff contact block (800T-XD4V)
D4 or J – 1-NCLB contact block (800T-XD4)
A – 1-NC + 1-NO contact block (800T-XA)
AV or F – 1-NC + 1-NO Pentuff contact block (800T-XAV)
A4 or N – 2-NC contact blocks (800T-XA4)
D2 or E – 1-NC contact blocks (800T-XD2)
D2V or U – 1-NC Pentuff contact block (800T-XD2V)
A1 or B – 1-NCLB + 1-NO contact block (800T-XA1)
A7 or C – 1-NCLB + 1-NC contact block (800T-XA7)
D4M or 4 – 1-NCLB Max Duty contact block (800T-XD4M)
D2M or 2 – 1-NC Max Duty contact block (800T-XD2M )
D6 or L – 1-NC Mini contact block (800T-XD6)
A5S – 2-NCLB self-monitoring contacts (qty. 2 - 800TC-XD4S)
B – 2-NC + 2-NO contacts (qty. 2 – 800T-XA)
BV – 2-NC + 2-NO Pentuff contacts (qty. 2 – 800T-XAV)
C – 4-NC + 4-NO contacts (qty. 4 – 800T-XA)
CV – 4-NC + 4-NO Pentuff contacts (qty. 4 – 800T-XAV)
H – 3-NC + 3-NO contacts (qty. 3 – 800T-XA)
HV – 3-NC + 3-NO Pentuff contacts (qty. 3 – 800T-XAV)
Document Control Number: LCC-0213-B-EN 2 / 5
Illuminated Trigger Action Emergency Stop Buttons:
1 2 3 4 5 6 7 8
1 Designates Product Line
800T – 30mm, metal operator
800H – 30mm, plastic operator
2 Designates Terminal Guard Option
Blank – Without terminal guard
C – With terminal guard
3 Designates Head Type
800T Head Options:
TFX – 45mm mushroom head
TFXJ – 60mm jumbo mushroom head
TFXJE – 60mm jumbo mushroom head with text
T – Twist-to-release
5 Designates Illumination Options
DTH – Dual input relay type (transformer), LED lamp
PH – Transformer type, LED lamp
QH – Full voltage type, LED lamp
800H Head Options:
TFRX – 45mm mushroom head
TFRXJ – 60mm jumbo mushroom head
TFRXJE – 60 mm jumbo mushroom head with text
00 – operator only
2 – 12-130V (full voltage, ac/dc)
16 – 120V (transformer)
26 – 240V (transformer)
46 – 480V (transformer)
56 – 600V (transformer)
7 Designates Cap Colour
R – Red
8 Designates Contact Block Configuration
D4S or 3 – 1-NCLB self-monitoring contact block (800TC-XD4S)
D4V or Q – 1-NCLB Pentuff contact block (800T-XD4V)
D4 or J – 1-NCLB contact block (800T-XD4)
A – 1-NC + 1-NO contact block (800T-XA)
AV or F – 1-NC + 1-NO Pentuff contact block (800T-XAV)
A4 or N – 2-NC contact blocks (800T-XA4)
D2 or E – 1-NC contact blocks (800T-XD2)
D2V or U – 1-NC Pentuff contact block (800T-XD2V)
A1 or B – 1-NCLB + 1-NO contact block (800T-XA1)
A7 or C – 1-NCLB + 1-NC contact block (800T-XA7)
D4M or 4 – 1-NCLB Max Duty contact block (800T-XD4M)
D2M or 2 – 1-NC Max Duty contact block (800T-XD2M )
D6 or L – 1-NC Mini contact block (800T-XD6)
G1 – 2-NC + 2-NO contacts (qty.2 - 800T-XA)
G1V – 2-NC + 2-NO Pentuff contacts (qty. 2 – 800T-XAV)
Document Control Number: LCC-0213-B-EN 3 / 5
Non-Illuminated Emergency Stop Buttons:
1 2 3 4 5
1 Designates Product Line
800T – 30mm, metal operator
800H – 30mm, plastic operator
2 Designates Terminal Guard Option
Blank – Without terminal guard
C – With terminal guard
3 Designates Head Type
800T Head Options:
FX – 45mm mushroom head
FXJ – 60mm jumbo mushroom head
FXJE – 60mm jumbo mushroom head with text
FXL – 63mm metal head
FXLE – 63mm metal head with text
FXT – Push-pull/twist-release
FXJT – Jumbo push-pull/twist-release
FXC – 90mm plastic mushroom head
4 Designates Cap Colour
6 – Red
800H Head Options:
FRX – 45mm mushroom head
FRXJ – 60mm jumbo mushroom head
FRXJE – 60 mm jumbo mushroom head with text
FRXT – Push-pull/twist-release
FRXJT – Jumbo push-pull/twist-release
5 Designates Contact Block Configuration
D4S or 3 – 1-NCLB self-monitoring contact block (800TC-XD4S)
D4V or Q – 1-NCLB Pentuff contact block (800T-XD4V)
D4 or J – 1-NCLB contact block (800T-XD4)
A1 or B – 1-NCLB + 1-NO contact block (800T-XA1)
A7 or C – 1-NCLB + 1-NC contact block (800T-XA7)
D4M or 4 – 1-NCLB Max Duty contact block (800T-XD4M)
A5 – 2-NCLB contacts (qty. 2 – 800T-XD4)
A1S – 1-NCLB + 1-NO contact (800TC-XD4S and 800T-XD1)
A5S – 2-NCLB self-monitoring contacts (qty. 2 - 800TC-XD4S)
Illuminated Emergency Stop Buttons:
1 2 3 4 5 6 7 8
1 Designates Product Line
800T – 30mm, metal operator
800H – 30mm, plastic operator
2 Designates Terminal Guard Option
Blank – Without terminal guard
C – With terminal guard
3 Designates Head Type
800T Head Options:
FX – 45mm mushroom head
FXJ – 60mm jumbo mushroom head
FXJE – 60mm jumbo mushroom head with text
800H Head Options:
FRX – 45mm mushroom head
FRXJ – 60mm jumbo mushroom head
Blank – Push-pull only
T – Twist-to-release
5 Designates Illumination Options
P – Transformer Incandescent
PH – Transformer type, LED lamp
Q – Full Voltage Incandescent
QH – Full voltage type, LED lamp
D – Dual input diode type
DT – Dual input transformer relay type
DTH – Dual input relay type (transformer), LED lamp
2 – 12-130V (full voltage, ac/dc)
Document Control Number: LCC-0213-B-EN 4 / 5
16 – 120V (transformer)
26 – 240V (transformer)
46 – 480V (transformer)
56 – 600V (transformer)
5 Designates Cap Colour
R – Red
6 Designates Contact Block Configuration
D4S or 3 – 1-NCLB self-monitoring contact block (800TC-XD4S)
D4V or Q – 1-NCLB Pentuff contact block (800T-XD4V)
D4 or J – 1-NCLB contact block (800T-XD4)
A1 or B – 1-NCLB + 1-NO contact block (800T-XA1)
A7 or C – 1-NCLB + 1-NC contact block (800T-XA7)
D4M or 4 – 1-NCLB Max Duty contact block (800T-XD4M)
A5 – 2-NCLB contacts (qty. 2 – 800T-XD4)
A1S – 1-NCLB + 1-NO contact (800TC-XD4S and 800T-XD1)
Document Control Number: LCC-0213-B-EN 5 / 5