マニュアル 英語(PDF:331.56KB)
[Startup and Maintenance Precautions]
WARNING
Do not touch live terminals. There is a danger of electric shock or malfunction.
Shut off the external power supply for the system in all phases before cleaning or
retightening the terminal screws. Failure to do so may result in electric shock or cause the
MELSEC-Q Series module to fail or malfunction. Loose screws can lead to dropping,
shorting, and malfunction. Excessive tightness of the screws can lead to breakage of the
screws, Conversion Adapter, Mounting Bracket, or MELSEC-Q Series Module, possibly
causing the dropping, shorting, and malfunction thereof.
ERNT-AQB68
Do not drop the Conversion Adapter and Mounting Bracket or do not give a strong impact
to it. This will cause damage.
ERNT-AQB65
CAUTION
(Always read these precautions prior to use.)
Before using this product, please read this manual carefully and pay full attention to safety to ensure that
the product is used correctly.
The precautions presented in this manual are concerned with this product only. For Programmable
Controller system safety precautions, refer to the user’s manual of the MELSEC-Q series CPU module to
be used.
In this manual, the safety precautions are ranked as “WARNING” and “CAUTION.”
Indicates that incorrect handling may cause hazardous conditions,
resulting in medium or minor injury and/or property damage.
Note that failure to observe the
CAUTION level instructions may lead to a serious consequence
according to the circumstances. Always follow the precautions of both levels because they are important
to personal safety.
Please keep this manual in an easy-to-access location for future reference, and be sure to provide the
manual to the end user.
Q68B(*2)
790
Q63B Q52B(*5) ERNT-AQF3
ERNT-AQF8
238×240
411×240
650
870
ERNT-AQF5
297×240
655
Q52B(*5) ERNT-AQF3
183×240
505
ERNT-AQF5
Q65B(*3)
Q55B(*4)
This manual describes specifications, handling and other information about the Conversion Adapter
“ERNT-AQTB20-S1” available as Renewal Tools for the Mitsubishi General-Purpose Programmable
Controller.
Before attempting to make a switch to MELSEC-Q Series in your installation, consult the user's
manual supplied with individual module under the latter series to learn about how they differ in various
aspects including performance and function.
CAUTION
Use the Conversion Adapter in the environmental conditions that are specified in the general
specification. If the Products are used in any environment beyond the bounds of the general
specification, electric shock, fire, malfunction, or damage to or degradation of the Products will
result.
Do not directly touch any conductive parts of Conversion Adapter. Contact will cause
malfunction or failure in the system.
Fasten the Conversion Adapter and the Mounting Bracket securely with retaining screws, and
tighten the screws by applying torque within specified limits. Loose screws can lead to the
dropping of the Conversion Adapter or Mounting Bracket, possibly causing breakage thereof.
Excessive tightness of the screws can lead to breakage of the screws, Conversion Adapter,
Mounting Bracket, or MELSEC-Q Series Module, possibly causing the dropping, shorting, and
malfunction thereof.
When installing the Conversion Adapter, take care not to get your hand snagged on the
Mounting Bracket or the like. Injury may result.
When installing or removing the MELSEC-Q Series Module complete with a Converter
Adapter, be sure to hold it with both hands. Dropping may lead to breakage.
[Wiring Precautions]
WARNING
Before attempting to install the Unit or carry out the necessary wiring, make certain that the
external power supply, used in the system, is shut off on all three phases. Failure to do so may
result in electric shock or damage to the product.
After installation and wiring, close the terminal block cover before turning on the module for
operation. Failure to do so may result in electric shock.
CAUTION
Carry out wiring for the Conversion Adapter correctly after checking the specification and
terminal arrangement for the module used. Connecting a power supply with a different
voltage rating or incorrect wiring may cause a fire or failure.
Tighten the terminal installation screws and terminal screw securely by applying torque
within the specified limits. Loose screws will cause short circuit, fire or malfunction.
Excessive tightening will damage the screws or the Conversion Adapter which in turn will
cause dropping of parts, short circuit or malfunction.
Use care to prevent foreign materials including cuttings and wiring debris from entering the
Conversion Adapter or the MELSEC-Q Series Module. These will be cause for fire, failure
or malfunction.
Mounting bracket
2
L
L
L
L
L
L
L
L
L
L
L
~
100 to 240VAC
Signal
name
Y00
Open
Y01
Open
Y02
Open
Y03
Open
Y04
Open
Y05
Open
Y06
Open
Y07
Open
Y08
Open
Y09
Open
Y0A
Open
Y0B
Open
Y0C
Open
Y0D
Open
Y0E
Open
Y0F
Open
COM
Open
COM
Open
Open
Open
(5) MELSEC-Q Series module specification
Round-shaped non-insulated
solderless terminal
MIN 3.2(※)
Unit:mm
Round-shaped solderless terminal
with an insulation sleeve
MIN 3.2(※)
MIN
φ3.2
MIN
φ3.2
Y-shaped non-insulated
solderless terminal
Y-shaped solderless terminal
with an insulation sleeve
MIN 3.2(※)
MIN 3.2(※)
MAX 3.5
MAX 3.5
Terminal block
Terminal block
(with a short bar)
1
Solderless terminal
1
●Terminal block shape
1
-
1
2.General Specifications
Item
Operating ambient
temperature
Storage ambient
temperature
Operating ambient
humidity
Storage ambient
humidity
L
Short bar
Shape Quantity
Mounting bracket fixing
screws (M3.5 x 6)
This manual
L
QY22
※The minimum length is 5.0 mm when the solderless terminal is attached up side down as shown below.
Once you have opened the packaging, verify that it contains the following products.
Product
L
MELSEC-Q Series module model
Unit:mm
M3 screw
[Installation Precautions]
TB1
Y00
TB2
Open TB3
Y01
TB4
Open TB5
Y02
TB6
Open TB7
Y03
TB8
Open TB9
Y04
TB10
Open TB11
Y05
TB12
Open TB13
Y06
TB14
Open TB15
Y07
TB16
Open TB17
Y08
TB18
Open TB19
Y09
TB20
Open TB21
Y0A
TB22
Open TB23
Y0B
TB24
Open TB25
Y0C
TB26
Open TB27
Y0D
TB28
Open TB29
Y0E
TB30
Open TB31
Y0F
TB32
Open TB33
COM
TB34
Open TB35
COM
TB36
Open TB37
Open
TB38
Open
The conversion adapter can be used in combination with the following MELSEC-Q series module.
●Applicable solderless terminal
When making a switch to the MELSEC-Q Series, be sure to consult user's manual supplied
with individual module under the MELSEC-Q Series to confirm differences in various aspects
including performance, function, CPU input/output signals between the two modules.
L
Terminal
block
Terminal
No.
TB1
TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9
TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38
(2) Specifications of the terminal block (conversion adapter accessory)
1.Overview
Quantity
L
(1) MELSEC-Q Series module
Output
Authorized representative in Europe is shown below.
Name: Mitsubishi Electric Europe BV
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
Shape
QY22
For the details of specifications of the MELSEC-Q series modules not described herein, refer to the user's manual of
the applicable MELSEC-Q series module. Also, check that the specifications of the connected devices meet
the specifications of the MELSEC-Q series module.
Input/Output
Authorized representative in Europe
Conversion Adapter
352×240
Q65B(*3)
Q55B(*4)
(4) External connection
4.Product Specifications
Compliance to the EMC Directive, which is one of the EU Directives, has been a legal obligation
for the products sold in European countries since 1996 as well as the Low Voltage Directive
since 1997.
Manufacturers who recognize their products are compliant to the EMC and Low Voltage
Directives are required to declare that print a "CE mark" on their products.
[Precautions before using]
CAUTION
930
ERNT-AQB52
When disposing of the product, treat it as industrial waste.
Product
466×240
Q68B(*2)
Q68B(*2)
8.6
CAUTION
Indicates that incorrect handling may cause hazardous conditions,
resulting in death or severe injury.
675
7.2
WARNING
795
247×240
Q612B
ERNT-AQB55
EMC AND LOW VOLTAGE DIRECTIVES
SAFETY PRECAUTIONS
382×240
Q33B
MIN
3.2
HEAD OFFICE: Hulic KUDAN BLDG.1-13-5,KUDANKITA CHIYODA-KU,TOKYO 102-0073,JAPAN
NAGOYA ENGINEERING OFFICE:139 SHIMOYASHIKICHO-SHIMOYASHIKI,KASUGAI,AICHI 486-0906,JAPAN
970
Q35B
ERNT-AQB62
ERNT-AQB58
[Disposal Precautions]
480×240
Q38B(*1)
Q38B(*1)
ERNT-AQB32
Do not modify the Conversion Adapter or take it apart. Doing so will cause failure,
malfunction, personal injury, or fire.
ERNT-AQF12, ERNT-AQF8
ERNT-AQF8
ERNT-AQF8, ERNT-AQF5
ERNT-AQF5
ERNT-AQF3
ERNT-AQF12, ERNT-AQF8
ERNT-AQF8
ERNT-AQF8, ERNT-AQF5
MAX
7.2
50CM-D180195-B(1602)
Q312B
ERNT-AQB35
CAUTION
User’s Manual
ERNT-AQB38
MIN
3.2
ERNT-AQTB20-S1
MAX
7.2
Model
MAX
7.2
Conversion Adapter
MAX
7.2
Mitsubishi General-Purpose Programmable Controller
Renewal Tool
(2) Base Adapter (Sold Separately)
Both the MELSEC-Q series base unit and the conversion adapter anchor base can be installed on the
base adapter without drilling screw holes.
However, drilling screw holes (M5 screws) is required to install the base adapter to the panel surface.
For the base unit models marked with *1 to *5, two or more base adapter models are applicable.
Select the most suitable base adapter according to the product dimensions.
Product
Installable
dimensions Weight
Base adapter
model
MELSEC-Q Series base unit
Conversion Adapter Width×Height (g)
(mm)
Anchor Base
12 slots 8 slots
5 slots 3 slots 2 slots
4.75 3.5
Specifications
0 to 55℃(Maximum surrounding air temperature 55℃)
-25 to 75℃
5 to 95%RH,non-condensing
Constant
Half
Frequency
Sweep count
acceleration amplitude
Compliant with
Under
5 to 8.4Hz
-
3.5mm
10 times each in
Vibration
JIS B 3502 intermittent
X, Y, Z directions
8.4 to 150Hz 9.8m/s2
-
resistance
and
vibration
IEC 61131-2
Under
5 to 8.4Hz
-
1.75mm
continuous
-
2
-
vibration 8.4 to 150Hz 4.9m/s
Compliant with JIS B 3502 and IEC 61131-2
Shock resistance
(147 m/s2, 3 times each in 3 directions X, Y, Z)
Operating atmosphere
No corrosive gases
Operating altitude *1
0 to 2000m
Installation location
Inside a control panel
Overvoltage category *2
II or less
Pollution degree *3
2
*1:Do not use or store under pressure higher than the atmospheric pressure of altitude 0m.
*2:This indicates the section of the power supply to which the equipment is assumed to be connected between
the public electrical power distribution network and the machinery within premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
*3:This index indicates the degree to which conductive material is generated in terms of the environment in
which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by
condensing must be expected occasionally.
3.Products Required by the Conversion Adapter
(1) Conversion Adapter Anchor Base (Sold Separately)
The conversion adapter anchor base secures the bottom of the conversion adapter. One anchor
base is required per base unit.
Conversion Adapter Anchor Base model
Specifications
Weight (g)
ERNT-AQF12
12-slot conversion adapter anchor base
590
ERNT-AQF8
8-slot conversion adapter anchor base
410
ERNT-AQF5
5-slot conversion adapter anchor base
275
ERNT-AQF3
3-slot conversion adapter anchor base
185
(3) Internal connection
Terminal
block
TB1
TB2
Open TB3
TB4
Open TB5
TB6
Open TB7
TB8
Open TB9
TB10
Open TB11
TB12
Open TB13
TB14
Open TB15
TB16
Open TB17
TB18
Open TB19
TB20
Open TB21
TB22
Open TB23
TB24
Open TB25
TB26
Open TB27
TB28
Open TB29
TB30
Open TB31
TB32
Open TB33
TB34
Open TB35
TB36
Open TB37
TB38
Open
All the even-numbered
terminals on the left
side are open.
Short bar
Already installed
to the terminal
block. Do not
remove it.
ERNT-AQTB20-S1
TB1
TB2
TB3
TB4
TB5
TB6
TB7
TB8
TB9
TB10
TB11
TB12
TB13
TB14
TB15
TB16
TB17
TB18
TB19
TB20
TB21
TB22
TB23
TB24
TB25
TB26
TB27
TB28
TB29
TB30
TB31
TB32
TB33
TB34
TB35
TB36
TB37
TB38
TB1
TB2
TB3
TB4
MELSEC-Q Series
TB5
module
TB6
TB1
TB7
TB2
TB3
TB8
TB4
TB5
TB9
TB6
TB7
TB10
TB8
TB9
TB11
TB10
TB11
TB12
TB12
TB13
TB13
TB14
TB15
TB14
TB16
TB17
TB15
TB18
TB16
TB17
TB18
Model
Specification
Number of output points
Isolation method
Rated load voltage
Maximum load current
Maximum inrush current
Leaked current at OFF
Maximum voltage drop at ON
Response OFF to ON
time
ON to OFF
Surge suppressor
Fuse
Internal current consumption
Common terminal arrangement
QY22
16 points
Photocoupler isolation
100 to 240VAC 50/60Hz±5%
0.6A/point,4.8A/common
20A cycle or less
3mA or lower (240V 60Hz) 1.5mA or lower (120V 60Hz)
1.5V or lower
1ms + 0.5 cycles or less
1ms + 0.5 cycles or less (rated load,resistive load)
CR absorber
No
250mA(MAX. all points ON)
16 points/common
6.2 Tightening Torque
5.Mounting and Installation
5.1 Handling Precautions
(1) Before attempting to install the Unit or carry out the necessary wiring, make certain that the
external power supply, used in the system, is shut off on all three phases. Failure to do so may
result in electric shock or damage to the product.
(2) Do not touch live terminals. There is a danger of electric shock or malfunction.
(3) Do not modify the Conversion Adapter or take it apart. Doing so will cause failure, malfunction,
personal injury, or fire.
(4) Do not touch the energized part of the Conversion Adaptor directly. Contact will cause
malfunction or failure in the system.
(5) Fasten the Conversion Adapter and the Mounting bracket securely with retaining screws, and
tighten the screws by applying torque within specified limits. Loose screws can lead to the
dropping of the Conversion Adapter, or Mounting bracket, possibly causing breakage thereof.
Excessive tightness of the screws can lead to breakage of the screws, Converter Adaptor,
Mounting bracket, or MELSEC-Q Series Module, possibly causing the dropping, shorting, and
malfunction thereof.
(6) Use care to prevent foreign materials including cuttings and wiring debris from entering the
Conversion Adapter or the MELSEC-Q Series Module. These will be cause for fire, failure or
malfunction.
(7) Do not drop the Conversion Adapter and Mounting Bracket or do not give a strong impact to it.
This will cause damage.
Tighten the installation screws to the specified torque below. An inappropriate tightening torque could
cause the product to fall or result in a short circuit, product failure or malfunction.
Screw Location
Tightening Torque Range
Conversion adapter anchor base installation screw (M4×8)
1.39 to 1.89N・m
Mounting bracket fixing screw (M3.5×6)
0.68 to 0.92N・m
Conversion Adapter installation screw (M3×35)
0.43 to 0.57N・m
Conversion Adapter bottom installation screw (M3×45)
Terminal block installation screw (M4 screw)
1.02 to 1.38N・m
Terminal block screw (M3 screw)
0.43 to 0.57N・m
7.External Dimensions
Unit:mm
Conversion adapter
Terminal block
Mounting bracket
1
2
3
4
5
6
5.2 Use Precautions
92
Width dimension of module
The module width dimension is 27.4
mm. Check the conditions for wiring
space and installation.
Depth dimension
The depth dimension required for
installation is 176.2 mm. Check the
installation condition.
9
10
11
12
13
14
15
16
17
204
Item
7
8
18
19
20
21
Conversion adapter
22
23
24
Use
Precautions
25
26
Base adapter
27
25.7
28
29
30
31
32
Conversion adapter
anchor base
176.2
164.4(※)
27.4
33
34
35
36
37
38
※When the base adapter is
not used
5.3 Installation Environment
18.9
41.9
The installation environment is the same as MELSEC-Q series CPU Module to use. Refer to the user's
manual of the MELSEC-Q Series CPU Module to be used.
6.Part Names and Installation Method
MELSEC-Q series module
Duplication Prohibited
This manual may not be reproduced in any form, in part or in whole, without written permission from
Mitsubishi Electric Engineering Company Limited.
©2015 MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED ALL RIGHTS RESERVED
2
2
Conversion adapter installation screw
M3 x 30
3
Terminal block installation screw
(M4)
4
2
4
MELSEC is a registered trademark of Mitsubishi Electric Corporation.
6
Precaution
Conversion adapter anchor base
Weight:265g
27.4
Mounting bracket (conversion adapter accessory)
Mounting bracket fixing screw
M3.5 x 6 (conversion adapter accessory)
Terminal block
(conversion adapter accessory)
Conversion adapter
Existing wiring
Conversion adapter
bottom installation screw
M3 x 45
7
5
1
Conversion adapter anchor base installation screw
M4 x 8 (conversion adapter anchor base accessory)
6
Terminal block screw (M3)
Product Warranty Details
Please confirm the following product warranty details prior to product use.
6.1 Installation Method
Gratis Warranty Terms and Gratis Warranty Range
① Secure the conversion adapter anchor base to the base adapter or control panel using the
conversion adapter anchor base installation screws (M4
locations)
8) provided as an accessory. (Two end
② Remove the terminal block attached with the MELSEC-Q Series module after loosening the
terminal block installation screws (2 places top and bottom).
MELSEC-Q Series terminal block installation screw
(Secure it in two places, top and bottom.)
If any fault or defect (hereinafter referred to as “Failure”) attributable to Mitsubishi Electric Engineering
Company Limited (hereinafter referred to as “MEE”) should occur within the gratis warranty period,
MEE shall repair the product free of charge via the distributor from whom you made your purchase.
Gratis Warranty Period
The gratis warranty period of this product shall be one (1) year from the date of purchase or
delivery to the designated place.
Note that after manufacture and shipment from MEE, the maximum distribution period shall be six
(6) months, and the gratis warranty period after manufacturing shall be limited to eighteen (18)
months.
In addition, the gratis warranty period for repaired products shall not exceed the gratis warranty
period established prior to repair.
Gratis Warranty Range
The gratis warranty range shall be limited to normal use based on the usage conditions, methods
and environment, etc., defined by the terms and precautions, etc., given in the instruction
manual, user’s manual and caution labels on the product.
Warranty Period after Discontinuation of Production
Secure the mounting bracket to the Q series module using the mounting bracket fixing screws
[M3.5 6 (conversion adapter accessory); two upper/lower locations].
③ Mount the conversion adapter onto the mounting bracket.
Secure the conversion adapter using the conversion adapter installation screws (M3 30; 2
④ locations).
Precaution
Before tightening the installation screws, check that the Conversion Adapter has been
securely installed on the MELSEC-Q Series module. Tightening the screws in floating-off
state or tilting state will damage the Conversion Adapter installation screws and the
mounting bracket.
⑤ Secure the conversion adapter using the conversion adapter bottom installation screw (M3
(1) MEE shall offer product repair services (fee applied) for seven (7) years after production of the
product has been discontinued. Discontinuation of production shall be reported via distributors.
(2) Product supply (including spare parts) is not possible after production has been discontinued.
Exclusion of Opportunity Loss and Secondary Loss from Warranty
Liability
Regardless of the gratis warranty period, MEE shall not be liable for compensation for damages arising
from causes not attributable to MEE, opportunity losses or lost profits incurred by the user due to
Failures of MEE products, damages or secondary damages arising from special circumstances,
whether foreseen or unforeseen by MEE, compensation for accidents, compensation for damages to
products other than MEE products, or compensation for other work carried out by the user.
Changes in Product Specifications
45;
The specifications given in the catalogs, manuals and technical documents are subject to change
without notice.
⑥ Secure the terminal block to the conversion adapter using the terminal block installation screws
This document is a new publication, effective February 2016. Specifications are subject to change
without notice.
1 location).
(M4; two upper/lower locations).
⑦ Connect the existing wiring to the terminal block.
When any wires are left unconnected, connect them to open terminals or insulate them.
Developed February 2016
50CM-D180195-B
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement