AK-450 450W Single Output Power Supply Features :

AK-450 450W Single Output Power Supply Features :
AK-450
450W Single Output Power Supply
series
Features :
Universal AC input with active PFC
High efficiency up to 93%
+5V / 0.3A auxiliary output
150% Peak load Capability
1U profile, High power density
Built-in Constant current limiting circuit
Power OK signal ( Power good, Logic low)
Remote ON-OFF, Remote sense function
Protections : OVP, OLP, OTP, SCP, Fan failure
3 years warranty
AK-450-12
MODEL
Output
Input
24V
30V
36V
48V
37.5A
19A
15A
12.7A
9.5A
0~37.5A
0~19.0A
0~15.0A
0~12.7A
0~9.5A
450W
456W
450W
457W
456W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
91%
92%
93%
Rated Power
Ripple & Noise (Max.)
Voltage Adj. Range
Voltage Tolerance
Line Regulation
Load Regulation
Setup, Rise Time
Hold Up Time (Typ.)
Voltage Range
Frequency Range
Power Factor (Typ.)
Efficiency (Typ.)
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Note.3 150mVp-p
±10% Typical adjustment by potentiometer
Note.4 ±1.0%
±0.5%
±0.5%
800ms, 60ms at full load
16ms / 230VAC at full load
Note.5 90 ~ 264VAC 127 ~ 370VDC
Over Voltage
Over Temperature
Other
Note
47 ~ 63Hz
0.98 / 230VAC, 0.99 / 115VAC at full load
89%
91%
4.5A / 115VAC 2.2A / 230VAC
27A / 115VAC 54A / 230VAC
<1.0mA / 240VAC
Normally works within 105 ~ 150% rated output power for more than 3 sec and then shutdown
O/P voltage with auto-recovery, >150% rated power or short circuit is constant current limiting,
if o/p drop to 40% rating output voltage then shutdown and auto-recover 5 time, if fault condition
not remove in this 5 time, the system well be shutdown and re-power on to recover.
14.4 ~ 15.6V
28.8 ~ 31.2V
36.0 ~ 39.0V
57.8 ~ 62.4V
By detecting primary and secondary heat sink.
Protection type: Shut down o/p voltage (Auto recovers automatically after temperature goes down)
5V @ 0.3A (+/- 3%)
Remote ON/OFF Control
Power OK Signal
Working Temp.
Working Humidity
Storage Temp., Humidity
Temp. Coefficient
External switch or NPN Transistor to turn ON / OFF
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
-20 ~ +70°C (Refer to output load de-rating curve)
20 ~ 90% R.H non-condensing
-40~+85°C, 10 ~95% R.H
±0.02%/°C (0 ~ 50°C)
10 ~ 500Hz, 5G 10min/1cycle, period for 60 min each along X,Y,Z axes Compliance to
IEC 68-2-6, IEC 68-2-64
Safety Standards
Withstand Voltage
Isolation Resistance
UL 60950-1, 2nd Edition, TUV EN60950-1 : 2006+A11 Approved
EMI Conduction & Radiation
Harmonic Current
EMS Immunity
EN55022 : 1998+A1 : 2000+A2 : 2003 Class B
MTBF
Dimension (L*W*H)
Packing
43.2 ~ 46.8V
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Auxiliary Power
Vibration
Safety
&
EMC
AK-450-48
AK-450-36
12V
Protection
Environment
AK-450-30
Rated Current
Current Range
Over Load
Function
AK-450-24
DC Voltage Range
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC
EN61000-3-2 :2000+A2:2005 Class A, EN61000-3-3 : 1995+A1 :2001
IEC61000-4-2,3,4,5,6,8,11
????K HRS
199*105*41 mm / 7.83*4.13*1.61 inch
1.1 kg ; 15pcs / 17kg / 0.69 CUFT
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2.Derating may be needed under low input voltages. Please check the de-rating curve for more details.
3.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.
4.Tolerance: includes set up tolerance, line regulation and load regulation.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives.
REV. A9
10/10/19
1
AK-450
450W Single Output Power Supply
Mechanical Specification
series
Unit:mm[inch]
41 [1.614]
56.4 [2.22]
199 [7.835]
110 [4.331]
1
8
7
LED
Vadj. 2
Airflow
direction
5
11 [0.433]
4
AC Input & DC Output
Pin No. Assignment
3
105 [4.134]
4-M3 L=5
6
57 [2.244]
105 [4.134]
9.2 [0.362]
CN2
7
2
1
16.75 [0.659]
170 [6.693]
Pin No. Assignment
1
AC/L
2
AC/N
3
FG
4,5
-V
6,7
+V
8-M3(Both Sides) L=5
18 [0.709]
Control pin number assignment (CN2) : JST S8B-PHDSS or equivalent
Pin No. Assignment Pin No. Assignment Mating Housing
Terminal
5
AUX
GND
1
5
6
GND
EN+
2
PHDR-08VS SPHD-002T-P05
3
7
VS+
P-OK
8
4
ENVS-
Function Description of CN2
Pin No. Function
AUX
1
GND
2
3
P.OK
4
EN5
GND
6
EN+
7
VS+
8
VS-
Description
+5V / 0.3A auxiliary power
Ground
Power OK
Remote ON/OFF (–)
Ground
Remote ON/OFF (+)
Remote voltage sense (+)
Remote voltage sense (–)
REV. A9
10/10/19
2
AK-450
450W Single Output Power Supply
series
De-rating Curve
Load V.S I/P Voltage
Load V.S Temp.
Ta=25°C
100
100
90
Load (%)
Load (%)
80
60
80
70
60
40
50
20
40
-20
0
10
20
30
40
50
60
70
90
100
110
120
264
Input Voltage (Vac)
Ambient Temperature (°C)
Peak Loading
I
T-peak
T-PEAK represents the period during which the output current is at 110% to 150% of
nominal (shown as I-PEAK). Curve B shows the relationship between the percentage
of peak current (I-PEAK) and the allowable duration (T-PEAK).
If the peak current is taken for longer that the allowed duration indicated by curve B,
the output current will drop to a constant limited current of 105% of nominal, then.
The unit between peak currents (T-NORMAL) is dependant up on the output current drawn
between the peaks (I-NORMAL) and curve A shows the relationship between the two.
The higher the percentage of normal current (I-NORMAL) is of the nominal current,
the longer the interval (T-NORMAL) before the next peak current can be drawn.
I-peak
I-normal
T-normal
0
T
T-peak (sec.)
T-normal (sec.)
24
24
20
20
16
16
12
12
8
8
4
4
0
0
10
20
30
40
50
60
CURVE A
70
80
90
% I-normal
110 115 120 125 130 135 140 145 150
% I-peak
CURVE B
REV. A9
10/10/19
3
AK-450
450W Single Output Power Supply
series
1. Power OK Signal and Auxiliary output
* Place an additional capacitor to have a better
performance of auxiliary power operation.
* The grounding of "AUX" power should be
connected to "GND" port. If " V-" is connected
as Grounding, make sure to short the GND
and V- ports.
DC / DC
5V / 0.3A
*
470μF
10V
AUX.
LOAD
2. Remote ON/OFF Control
(A)
(B)
(C)
AUX
AUX
2KΩ
SW
2KΩ
EN+
AUX
2KΩ
EN+
EN+
5V
5V
5V
SW
5V
EN-
EN-
GND
GND
EN-
Tr
L/H
sw
OFF Power ON
GND
Tr
ON Power OFF
(A) Using internal 5V auxiliary source
L
Power ON
H
Power OFF
(B) ON / OFF Control by NPN transistor
GND
sw
OFF Power ON
ON Power OFF
(C) Using external voltage source
3. Remote Sense
CN2
1
2
8
+V
-V
GND
AUX
EN-
P-OK
EN+
GND
VS-
VS+
7
R Load
REV. A9
10/10/19
4